AirWalk Communications AWRCPB4W800 RCPB 4W Amp 800MHZ User Manual Product Specification

AirWalk Communications, Inc. RCPB 4W Amp 800MHZ Product Specification

user manual

Download: AirWalk Communications AWRCPB4W800 RCPB 4W Amp 800MHZ User Manual Product Specification
Mirror Download [FCC.gov]AirWalk Communications AWRCPB4W800 RCPB 4W Amp 800MHZ User Manual Product Specification
Document ID937839
Application ID3zWOUAbhq53RoSKnHo3dIg==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize90.56kB (1131943 bits)
Date Submitted2008-05-07 00:00:00
Date Available2008-05-07 00:00:00
Creation Date2008-05-06 13:55:51
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-05-06 13:58:10
Document TitleProduct Specification Document
Document CreatorAcrobat PDFMaker 8.1 for Word
Document Author: AirWalk Communications Inc

CDMA2000 1xRTT
IP Radio Access Network (IP-RAN)
OneRAN Pilot Station
Installation & Maintenance Manual
Version # 1.6
May 2008
Prepared By
AirWalk Communications, Inc.
1830 North Greenville Ave
Richardson, TX, 75081
Phone: (972) 638-9400
Fax: (972) 638-9401
www.airwalkcom.com
FOR USE BY TRAINED TECHNICIANS ONLY
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 1 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Revision History
Version
Date
Person
0.1
1.0
1.1
1.2
10/15/2005
11/23/2005
4/30/2006
6/14/2006
CMO
CMO
CMO
CMO
1.3
1/8/2008
CB
1.4
4/9/2008
R MacL
1.5
4/21/2008
R MacL
1.6
5/06/2008
R MacL
Description
Draft Document
Released
Pictures corrected
Added regulatory compliance information
Create separate Pilot Station document, update
nomenclature and photographs
Added RCPB description and RF Exposure
update
Deleted Section 2.5.4 RF Exposure and
updated label in Section 2.4.2
Deleted FCC Sample label and added Section
2.5.4 RF Power Requirements
Revision Numbering Key
0.x
Work in Progress
1.0
Initial Document Approval
1.x
Revisions Following Initial Document Approval
2.0
Revisions Approval
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 2 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Table of Contents
TABLE OF CONTENTS .................................................................................................................................. 3
INTRODUCTION ..................................................................................................................................... 5
1.1
PROPRIETARY INFORMATION NOTICE .................................................................................................. 5
1.2
PURPOSE OF DOCUMENT ...................................................................................................................... 5
1.3
SCOPE .................................................................................................................................................. 5
1.4
ORDER OF PRECEDENCE ....................................................................................................................... 5
1.5
TERMINOLOGY ..................................................................................................................................... 5
1.6
APPLICABLE DOCUMENTS .................................................................................................................... 5
1.6.1
AirWalk Documents..................................................................................................................... 5
1.6.2
Telecom Standards ...................................................................................................................... 6
1.6.3
Other Documents......................................................................................................................... 6
ONERAN PILOT STATION SAFETY AND COMPLIANCE INFORMATION .............................. 7
2.1
STATEMENT OF INTENT ........................................................................................................................ 7
2.2
SAFETY PRECAUTIONS ......................................................................................................................... 7
2.3
MAINTENANCE INFORMATION ............................................................................................................. 8
2.3.1
Cleaning ...................................................................................................................................... 8
2.3.2
Filter Maintenance ...................................................................................................................... 8
2.3.3
Fuse Replacement ....................................................................................................................... 8
2.3.4
Other Maintenance ...................................................................................................................... 8
2.4
LABELING ............................................................................................................................................ 9
2.4.1
Grounding ................................................................................................................................... 9
2.4.2
Label: Model Identification, FCC Identification, Power ............................................................ 9
2.5
REGULATORY COMPLIANCE INFORMATION ....................................................................................... 10
2.5.1
Radio Interference (FCC 15.19 Statement) ............................................................................... 10
2.5.2
Unauthorized Modifications (FCC 15.21 Statement) ................................................................ 10
2.5.3
Digital Device Interference (FCC 15.105 Statement) ............................................................... 10
2.5.4
RF Power Requirements ............................................................................................................ 10
ONERAN PILOT STATION SYSTEM INTRODUCTION ............................................................... 11
3.1
HARDWARE CONFIGURATION ............................................................................................................ 11
3.1.1
Physical Description ................................................................................................................. 11
3.1.2
Typical Configurations .............................................................................................................. 11
3.1.3
Installation Photographs ........................................................................................................... 12
3.2
BLOCK DIAGRAM – ONERAN PILOT STATION ................................................................................... 13
3.3
SYSTEM CAPACITIES AND SPECIFICATIONS ........................................................................................ 14
3.3.1
OneRAN Pilot Station Technical Specification ......................................................................... 14
3.3.2
IP-BS Power Supply & Environment Technical Specification .................................................. 15
ONERAN PILOT STATION COMPONENTS .................................................................................... 16
4.1
4.2
4.3
ONERAN PILOT STATION .................................................................................................................. 16
RF POWER AMPLIFIER BOARD (RCPB – 4 WATT) .............................................................................. 17
COMPONENT LED CONFIGURATION .................................................................................................. 18
ONERAN PILOT STATION INTERFACE CABLING ..................................................................... 20
5.1
5.2
5.3
RF CABLING ...................................................................................................................................... 20
ETHERNET/SERIAL CABLE WIRING .................................................................................................... 21
ELECTRIC POWER CABLE WIRING...................................................................................................... 21
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 3 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
ONERAN PILOT STATION FREQUENCY SETTING PROCEDURES ........................................ 22
6.1
BSM MANAGEMENT .......................................................................................................................... 22
6.2
LOCAL FA SETTING ........................................................................................................................... 22
6.2.1
MMI Connection ....................................................................................................................... 22
6.2.2
FA Change Procedure ............................................................................................................... 23
ONERAN PILOT STATION INSTALLATION PROCEDURES ..................................................... 25
7.1
INSTALLATION VERIFICATION ............................................................................................................ 25
7.1.1
Verify Customer Contact & Equipment location ....................................................................... 25
7.1.2
Uncrate and arrange for packing material disposal ................................................................. 26
7.1.3
Verify location of all Facility distribution points (main and intermediate).............................. 26
7.2
ONERAN PILOT STATION INSTALL PROCEDURES .............................................................................. 27
7.2.1
Install OneRAN Pilot Station Cabinet ....................................................................................... 27
7.2.2
External System Connections .................................................................................................... 28
7.2.3
Connect Power to Cabinet ........................................................................................................ 28
7.2.4
Connect Communications Facilities.......................................................................................... 28
7.2.5
Power-up procedure .................................................................................................................. 28
7.3
SYSTEM TEST ..................................................................................................................................... 29
7.3.1
PC to OneRAN Pilot Station cable ............................................................................................ 29
7.3.2
System Certification Tests ......................................................................................................... 29
7.3.3
Operation Tests ......................................................................................................................... 35
7.3.4
Operator Specific Tests ............................................................................................................. 35
7.4
SITE CLEAN UP AND CUSTOMER SIGNOFF .......................................................................................... 35
7.4.1
Dispose of all packing material. ................................................................................................ 35
7.4.2
Clean-up site ............................................................................................................................. 35
7.4.3
Update Installation Checklist. ................................................................................................... 36
7.4.4
Customer Signoff ....................................................................................................................... 36
7.5
REQUIRED TOOLS AND SUPPLIES ....................................................................................................... 36
7.6
TROUBLESHOOTING PROCEDURES ..................................................................................................... 36
7.6.1
Before Calling for Assistance .................................................................................................... 36
7.6.2
When Calling for Assistance ..................................................................................................... 37
APPENDIX A - ACRONYMS................................................................................................................ 38
APPENDIX B - SITE PREPARATION CHECKLIST ....................................................................... 42
10
APPENDIX C - INSTALLATION CHECKLIST ............................................................................ 45
11
APPENDIX D - CUSTOMER CERTIFICATION DOCUMENT .................................................. 48
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 4 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
1 INTRODUCTION
1.1 Proprietary Information Notice
THIS DOCUMENT IS THE PROPERTY OF AIRWALK COMMUNICATIONS, INC. THE
RECIPIENT MAY USE IT ONLY FOR THE PURPOSE FOR WHICH IT WAS
TRANSMITTED AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER
NEEDED BY RECIPIENT. IT MAY NOT BE COPIED OR COMMUNICATED WITHOUT
THE WRITTEN CONSENT OF AIRWALK COMMUNICATIONS, INC.
1.2 Purpose of Document
The purpose of this document is to define the Installation, Maintenance and Safety
Compliance of AirWalk Communication’s, Inc. unique CDMA Radio Access Network
(RAN) system. The AirWalk RAN is a market ready, standards compliant, high channel
capacity, cost effective, modular and expandable wireless radio access network system.
Designed specifically for CDMA2000 networks, the Base Station Transceiver (BTS) and
Base Station Controller (BSC) are integrated into a single compact platform.
The target market and applications are corporations, corporate campuses, enterprises,
university campuses, large industrial plants, stadiums, airports, shopping malls, blind
spots, hot spots, rural areas, neighborhoods, and highways.
1.3 Scope
The scope of this document covers the description, environmental specifications,
equipment location, cabling, system installation and maintenance of the AirWalk RAN.
The information contained in this manual was previously included in the combined
Installation & Maintenance Manual for the MiniCell and Pilot Beacon products.
1.4 Order of Precedence
This System Installation Manual will take precedence over any previous AirWalk System
Installation Manual or Document.
1.5 Terminology
See the section entitled: Appendix A - Acronyms
1.6 Applicable Documents
The following documents are applicable to the extent specified in this System Installation
Manual.
1.6.1 AirWalk Documents
•
IP- Base Station (BS) System Description.
•
IP- Base Station (BS) CPIB Block Diagram.
•
IP- Base Station (BS) GPSR Block Diagram.
•
IP- Base Station (BS) PCPM Block Diagram.
•
IP- Base Station (BS) XCVB Block Diagram.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 5 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
1.6.2 Telecom Standards
(1) TIA/EIA/IS-2000 Series Revision: C - Introduction to CDMA2000 Spread Spectrum
Systems, 05/00/02
(2) Personal Station – Base Station Compatibility Requirements for1.8 to 2.0 GHz CDMA
PCS.
(3) TIA/EIA-664 - Wireless Features Description, 12/00/00
(4) TIA/EIA Interim Standard 95 Revision A - Mobile Station –Base Station Compatibility
Standard for Dual-Mode Wideband Spread Spectrum Cellular Systems, May 1995
(5) TIA/EIA-95-B - Mobile Station-Base Station Compatibility Standard for Dual-Mode
Spread Spectrum Systems, October 31, 1998
(6) MSC to BS Interface Inter-Operability Specification (IOS) IOS-4.2
(7) IMT-2000 Specification, (indoor wireless propagation)
1.6.3 Other Documents
None Identified
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 6 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
2 OneRAN Pilot Station Safety and Compliance
Information
2.1 Statement of Intent
The AirWalk OneRAN Pilot Station is intended for use in a CDMA cellular infrastructure
radio access network. The responsible body shall be made aware that, if the equipment
is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
2.2 Safety Precautions
1) Power Sources
Use only power sources that are within the specified limits as designated on the
equipment labels. Use of power sources outside the specified limits is hazardous and
may cause personal injury or property damage.
2) Equipment Location
Equipment should be located indoors or in a suitable protected environment such as an
equipment enclosure. Use of unprotected equipment outdoors is hazardous and may
cause personal injury or property damage.
3) Grounding and Electrical Connections
Electrical connections including equipment grounding should be made in accordance with
the National Electric Code and any local regulations. Improper electrical connections are
hazardous and may cause personal injury or property damage. Consult a licensed
electrical installer if in doubt.
4) Hazardous Voltages
Equipment may contain hazardous voltages. Only qualified service personnel should
open the equipment for adjustments, repairs or replacements.
5) Replacement Parts
Damaged parts and protective devices such as fuses should only be replaced by
components approved or recommended by AirWalk Communications. Replacement
fuses must be of the same rating and type as the original for continued protection.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 7 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
2.3 Maintenance Information
2.3.1 Cleaning
The AirWalk OneRAN Pilot Station units are protected by a high performance paint which
does not require normal maintenance. If paintwork is soiled, it can be cleaned using a
damp cloth after AC power has been disconnected. Do not use liquids or spray cleaning
substances on the unit since property damage or personal injury may result.
2.3.2 Filter Maintenance
The OneRAN Pilot Station Unit is equipped with a washable air filter located in a front
mounted drop down door.
This filter should be checked annually for dirt build-up and cleaned if required. Note more
frequent inspections may be needed in dusty environments.
Air Filter Located In
Drop Down Front Door
2.3.3 Fuse Replacement
The OneRAN Pilot Station contains a 250 V 5A fuse located behind the AC connector
cap as shown in the diagram. Replace the fuse with the same type and ratings.
Removable
Fuse Cap
2.3.4 Other Maintenance
Any other required maintenance must be performed by suitable trained service personnel.
Do not open covers or attempt to repair unit if not suitably trained.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 8 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
2.4 Labeling
2.4.1 Grounding
Proper grounding is recommended to ensure good RF performance in addition to
personnel safety. Antenna systems should also be suitably grounded for good RF
performance.
Grounding connection points on the chassis are identified by this symbol:
2.4.2 Label: Model Identification, FCC Identification, Power
The following diagram illustrates the location of the FCC label that will be applied to the
OneRAN Pilot Station unit to provide model identification, FCC identification and rated
power supply information.
1.0
15.0
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 9 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
2.5 Regulatory Compliance Information
The FCC regulatory compliance information provided in this section is applicable only to
models equipped with an FCC identification number (FCC ID).
2.5.1 Radio Interference (FCC 15.19 Statement)
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
2.5.2 Unauthorized Modifications (FCC 15.21 Statement)
Persons or parties responsible for operation of this equipment are cautioned that any
changes or modifications not expressly approved by AirWalk Communications
Incorporated could void the user’s authority to operate this equipment.
2.5.3 Digital Device Interference (FCC 15.105 Statement)
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications.
2.5.4 RF Power Requirements
The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent
structures.
For systems built with additional RF amplification, power reduction is required at the band
edges to comply with FCC limits.
For the 4W RCPB the maximum RF power must not exceed the following:
Channel
Maximum Power
1013 – 1014
1015 – 775
776 – 777
0.109 Watts
4 Watts
0.726 Watts
For the 20W Slim RU the maximum RF power must not exceed the following:
Channel
Maximum Power
1013 – 1015
1016 – 773
774 – 777
0.140 Watts
20 Watts
0.500 Watts
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 10 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
3 OneRAN Pilot Station System Introduction
3.1 Hardware Configuration
The IP-BS is a unique modular and stackable combination BSC and BTS platform that is
differentiated from other systems. Other systems have separate BTS and BSC platforms
which add to cost and complexity. The AirWalk OneRAN Pilot Station has a structure that
combines and arranges the BSC interface with one the BTS in a single package.
The main components are:
o CDPB (Common Digital Processing Board), consisting of:
ƒ CPIB (Channel Processor and IF Interface Board) PB Only
ƒ PCPM (Primary Call Processor Module)
ƒ GPSR (Global Positioning System Receiver)
o XCVB-SP (RF Transceiver Board) Transmit Only configuration
o PSA (Power Supply Assembly)
o RCPB (RF Power amplifier Board) 4 Watt CDMA Power Amplifier
3.1.1 Physical Description
•
AirWalk OneRAN Pilot Station
o Dimension: Max. 482mm[19”](W) x 457mm[18”](D) x 178mm[7”](H)
o 19” EIA Rack x 4 Rack Units
o Weight: 15 kg [33 lbs]
3.1.2 Typical Configurations
The following shows typical component configurations for common applications. Refer to
the model charts for the contents of specific model numbers.
Omni Macrocell Pilot Station System (4W PPS)
- AirWalk OneRAN Pilot Station self contained unit
Omni Multi-Carrier Macrocell Pilot Beacon System (4W PPS, 3 carrier hopping)
- AirWalk OneRAN Pilot Station self contained unit with Multi-Carrier software
option
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 11 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
3.1.3 Installation Photographs
The following photographs show typical field installations for the AirWalk OneRAN Pilot
Station systems:
Figure 3-2 – Typical OneRAN Pilot Station System
Figure 3-3 – Typical OneRAN Pilot Station Rack Mounted
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 12 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
3.2 Block Diagram – OneRAN Pilot Station
To
RCPB
PSA
GPSR
CPIB
RCPB
XCVB
IF I/F - α
(A/D & D/A)
Processor
(MPC8250)
FPGA
(Control
Logic)
CSM5K
X3
HPAU
(4/8Watt)
UPCB
IF I/F - β
(A/D & D/A)
DPL
FEDB
DNCB
Duplexer
IF I/F - γ
(A/D & D/A)
From/To
Antenna
PCPM
Processor
(MPC8260)
Memory Block
From/To
CA & WPM
Gateway I/F
Figure 3-6 AirWalk OneRAN Pilot Station Hardware Structure
OneRAN Pilot Station Notes:
- FEDB not provided on all models
- OneRAN Pilot Station may not be equipped with diversity receiver
- OneRAN Pilot Station may not be equipped with 3 CSM-5000 or receiver A/D & IF
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 13 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
3.3 System Capacities and Specifications
3.3.1 OneRAN Pilot Station Technical Specification
Item
Capacity and
Specification
Up-Link: 1850 ~ 1910 MHz
Down-Link: 1930 ~ 1990 MHz
Up-Link: 824 ~ 849 MHz
Down-Link: 869 ~ 894 MHz
Frequency Band
1FA/Omni
3FA Hopping Pilot Beacon
Handoff
Softer H/O, soft H/O. Hard H/O
GPS
External GPS Antenna
Installation
Rack Mountable
Cooling
Forced Air
IP-Network Interface
10/100 Base-T Ethernet
Transmitter output power
4W Internal RU system
Antenna A (Tx/RxA)
RF Interface
Antenna B (RxB)
J-STD-008/IS-95-A/IS-95B
Common Air Interface (CAI)
/CDMA2000-1x
Channel bandwidth
1.25MHz
FA
Remarks
North American PCS Band
800 MHz Cellular Band
Each Pilot Station Unit
One per Pilot Station
4 Rack Units
Front To Rear Flow
Includes duplexer
CDMA 2000 1xRTT
Mechanical Specification
RF Input and Output
Connector
AC Power Connector
Ethernet Signal Port
Connectors
Dimensions ( WxHxD )
Weight
SMA Female (Input/Output)
From/To Antenna
System
IEC
RJ-45
482mm(W) x 457mm(D) x 178mm(H)
19”(W) x 18”(D) x 7”(H)
15 kg [33 lbs]
4 Rack Units
Table 3-1 – AirWalk OneRAN Pilot Station Specifications
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 14 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
3.3.2 IP-BS Power Supply & Environment Technical Specification
Input Power Supply
Input Voltage:
Input Frequency:
AC 100Volts ~ 250Volts
50Hz ~ 60Hz
Dissipated Power
Main Unit:
350 Watt Max (Efficiency 75%)
Environment Specification
Operating Temperature
Storage Temperature
Relative Humidity
Noise
Airborne Particle
0o ~ +50 o
-30 o ~ +60 o
5% ~ 95% - Non-condensing
Less than 60dBA, distance 1.5m
0 ~ 90 ㎍/㎥
Table 3-3 - Power Supply & Environment Specifications
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 15 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
4 OneRAN Pilot Station Components
4.1 OneRAN Pilot Station
Figure 4-1 OneRAN Pilot Station Photo (Front View)
RCPB
FEDB
XCVB
PSU
CDPB
Figure 4-2 OneRAN Pilot Station Line Diagram (Front View)
FEDB: not used with OneRAN Pilot Station
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 16 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Figure 4-3 OneRAN Pilot Station Photo (Back View)
Figure 4-4 OneRAN Pilot Station – Line Diagram (Back View)
4.2 RF Power amplifier Board (RCPB – 4 Watt)
RCPB (RF Power amplifier Board) is an integrated 4 Watt CDMA Power Amplifier.
Integrated meaning that this unit is one of the modules installed into the OneRAN
chassis. This unit is provided for use in the mini macro cell and Pilot Station systems
with medium sized geographic coverage areas.
The RCPB contains a High Power RF amplifier to increase the downlink signal strength
from the RF Transceiver Board (XCVB) to the broadcast antenna. The RCPB is used
predominately in an omni cell site configuration.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 17 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
4.3
.3 Component LED Configuration
CDPB: LED status indicators are provided on the OneRAN Pilot Station CDPB module.
LED functions are described in the following pictures and tables.
PWR
CDPB
FLT
BTS
MMI
CPIB
GPSR
BSC
MMI
RESET
CPIB
PCPM
PCPM
SCPM
SCPM
Figure 4-9 CDPB Panel Diagram
Figure 4-10 - CDPB Panel Photo
Name
Color
On
Off
Note
CPIB
GPSR
PCPM
SCPM
Green
Green
Green
Green
Normal
Normal
Normal
Normal
Abnormal
Abnormal
Abnormal
Abnormal
CPIB
Orange
Abnormal
Normal
GPSR
Orange
Abnormal
Normal
PCPM
Orange
Abnormal
Normal
SCPM
Orange
Abnormal
Normal
CPIB power on/off indicator
GPSR power on/off indicator
PCPM power on/off indicator
SCPM power on/off indicator
Check function of CPU in CPIB
Board and ALARM
GPSR alarm on/off indicator
Check function of CPU in
PCPM Board and ALARM
Check function of CPU in
SCPM Board and ALARM
Table 4-1 – CDPB Indicator Codes
NOTE: OneRAN Pilot Station units are NOT normally equipped with an SCPM
(Secondary Call Processor Module), therefore these indicators are not used in most
system applications.
XCVB: The XCVB module is equipped with 2 indicators. LED functions are described in
the following pictures and tables.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 18 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
XCVB
PWR
FLT
Figure 4-11 - XCVB Panel Diagram
Figure 4-12 XCVB Panel Photo
Name
PWR
FLT
Color
On
Green
Orange
Off
Normal
Abnormal
Abnormal
Normal
Note
XCVB power on/off indicator
XCVB alarm on/off indicator
Table 4-2 - XCVB Indicator Code Key
RCPB: The RCPB module is equipped with 2 indicators. LED functions are described in
the following pictures and tables.
RCPB
PWR ACT/FLT
Figure 4-13 - RCPB Panel Diagram
Figure 4-14 RCPB Panel Photo
Name
PWR
ACT/FLT
ACT/FLT
Color
Green
Green
Orange
On
Off
Note
Normal
Normal
Abnormal
Abnormal
(power off)
(power off)
RCPB power on/off indicator
RCPB alarms are clear
RCPB alarm/fault
Table 4-3 - RCPB Indicator Code Key
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 19 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
5 OneRAN Pilot Station Interface Cabling
5.1 RF Cabling
The OneRAN Pilot Station Antenna port is connected to the external antenna system as
shown in Figure 6.2 (cables not included). External connector is SMA type.
The OneRAN Pilot Station is not equipped with any receivers, therefore there is no
duplexer requirement for normal operation. Note the main antenna port may be marked
Txα on some enclosures.
Antenna systems must include suitable protection against lightning and other hazards in
accordance with conventional cell site installation practices.
GPSANT
T_EVEN RF RXB(a)
RF RXA(a) RF TX (a)
T_10MHz RF RXB(b)
RF RXA(b) RF TX(b)
RF RXB(r)
RF RXA(r) RF TX (r)
RU IF
BSC IF
ENV IF
BTS IF
To Main
Antenna
Figure 6-2 RF Cabling Diagram
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 20 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
5.2 Ethernet/Serial Cable Wiring
Connect the external Ethernet connections (cable not supplied) from the local Ethernet
switch or hub at the cell site to the BTS and BSC Ethernet ports on the OneRAN Pilot
Station as shown in Figure 6.3. Use category 5 Ethernet cable (or better) for best
performance.
5.3 Electric Power Cable Wiring
Connect OneRAN Pilot Station to suitable AC power sources as shown in Figure 6-3.
Use only the AC power cables provided with the unit to ensure continued safe operation.
GPSANT
T_EVEN RF RXB(a)
RF RXA(a) RF TX (a)
T_10MHz RF RXB(b)
RF RXA(b) RF TX(b)
RF RXB(r)
RF RXA(r) RF TX (r)
RU IF
BSC IF
ENV IF
BTS IF
To Local
Ethernet
Switch/Hub
AC
Power
Figure 6-3 OneRAN Pilot Station Power & Ethernet Cabling
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 21 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
6 OneRAN Pilot Station Frequency Setting Procedures
6.1 BSM Management
The OneRAN Pilot Station base stations are normally managed by the centrally located
BSM (Base Station Manager) system which communicates with the unit over an IP
connection.
The BSM will download system software and configuration information which includes the
physical FA (Frequency Assignment) for each base station. The base station will tune to
the correct frequency as defined by the BSM configuration files.
Refer to the BSM operations manual for instructions on base station remote configuration.
6.2 Local FA Setting
It may be required to set the OneRAN Pilot Station physical FA (frequency assignment)
locally for specialized test purposes or when the BSM connection is unavailable (for
example during early BTS installations). This can be done using the local MMI (Man
Machine Interface) port and a local PC.
The configuration data downloaded from the BSM will override local settings when BSM
connections are established.
Refer to the MMI instruction manual for further information on other commands.
6.2.1 MMI Connection
Connect the serial port of the PC to the “BTS MMI” port on the OneRAN Pilot Station
front panel. Use the cable described in section 7.3.1 and the following port settings:
115200 baud
8 bit
No Parity
1 stop bit
No flow control
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 22 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
6.2.2 FA Change Procedure
The following menu driven commands will permit local change of the FA.
Step 1
At the prompt enter the following:
> pn3383
// this will take you to the menu screen which looks something like this:
================= PN 3383 ====================
1. Tx Test
2. Rx Test
3. ParameterSetup
4. Rf Gain Display
5. xcvbSetup
6. ampSetup
7. Normal Gain Display
8. MakeTestCall
9. callClear
10. Overhead Calibration Control
11. Test Phone Setup (619 2221001)
12. Handoff Test
0. Exit
-------------------------------------------------Select Number ===>
Step 2
Enter the following:
Select number => 5
// it will take you to the below menu screen.
================= Xcvb Setup ====================
1. Change Ch
2. Tx On
3. Tx Off
4. Rx_Main_AGC ON
5. Rx_Main_AGC OFF
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 23 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
6. Rx_Sub_AGC ON
7. Rx_Sub_AGC OFF
8. Set RxMain ATT
9. Set RxSub ATT
10. Set Tx Att
11. Xcvb Status
12. showXcvrAttGain
0. Exit
-------------------------------------------------Select Input Number =====>
Step 3
Enter the following:
Select Input Number => 1 // choosing 1 will take you to the below menu.
ALPHA : xcvrChangeCh Num [001 ~ 1500] [1175] [/0:Exit]==>
Step 4
From the above menu, type the new channel desired (CDMA channels from 1 to 1500)
and 0 to exit. Note that for 3 sector base stations Step 3 must be repeated for each
sector (alpha, beta, and gamma).
Note that only standard CDMA channel numbers within the designated band capability of
the radio will be accepted by the base station.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 24 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7 OneRAN Pilot Station Installation Procedures
This Section gives definitions and instructions for installing the OneRAN Pilot Station and
for connecting it to the wireless carrier’s infrastructure. It contains detailed definitions
needed for completing site Installation Checklist (Appendix B).
7.1 Installation Verification
Before installing the equipment, it is necessary to verify the following:
7.1.1 Verify Customer Contact & Equipment location
7.1.1.1 Contact Customer 1
1) Verify contact name check Site Preparation Planning Checklist Appendix B.
2) Verify contact phone number.
3) Introduce yourself to the Customer contact.
4) Introduce Installation team (if more than one person on team).
5) Verify that all current customer contacts are listed.
a) Verify that contacts can solve problems within a timely manner for:
i) Power Connection(s),
ii) T1 Connection(s),
iii) LAN Connection(s),
iv) If not, have main customer contact provide names and method of
contacting.
6) Determine when contacts are available for help (e.g.; Time of day, day of week.).
7) Obtain any site access or security requirements (e.g.: ID Badges, Card-keys, Keys,
Access codes) required to access installation site.
8) Indicate all changes on checklist.
7.1.1.2 Locate OneRAN Pilot Station Equipment. 2
1) Determine where OneRAN Pilot Station is stored.
2) Check for any visible shipment damage.
NOTE: Make sure all changes are sent to the Installation Coordinator Immediately.
NOTE: If any visible damage contact the Installation Coordinator immediately.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 25 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7.1.1.3 Locate and verify floor space.
1) Determine where the OneRAN Pilot Station is to be installed (Refer to site diagram
in Appendix B).
2) Verify that there is enough space to safely install it (Refer to site diagram in
Appendix B).
7.1.2 Uncrate and arrange for packing material disposal
1) Carefully unpack the OneRAN Pilot Station and related components from packing
material.
2) Check for any shipment damage. 3
3) Be certain that all components match system order. 4
4) Make arrangements with customer contact on where, when, and how to dispose of
all OneRAN Pilot Station packing material.
7.1.3 Verify location of all Facility distribution points
(main and intermediate)
7.1.3.1 Power Check
7.1.3.1.1 Power Location
1) Locate the customer provided power connection.
a) There should be a –48VDC connection for DC powered models (if required).
b) There should be a 120 or 240 VAC connection for AC powered models (if
required).
7.1.3.1.2 Verify Connector.
1) An 8 AWG three wire stranded cable to connect to a WECO DC terminal block
connector is required for –48VDC (if required).
2) A 6ft (1.84m) e conductor type SJT cables with standard grounded connector is
required for 110VAC connection (if required).
7.1.3.1.3 Voltage
NOTE: Note any damage on shipping report, and Installation Checklist. Contact
the Installation Coordinator immediately
NOTE: If components do not match the system order, contact the Coordinator
immediately.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 26 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
1) Using a power meter check for correct voltage.
a) –48VDC range is 40VDC to 57VDC (if required).
b) 120 VAC range is 90 VAC to 132 VAC (if required).
c) 240 VAC range is 180 VAC to 264 VAC (if required).
7.1.3.1.4 Amps
1) Check cables to determine if they will handle required Amps.
a) –48VDC should be able to support 27.9 Amps.
b) 120 VAC should support 15 Amps, 240 VAC should support 7.5 Amps
7.1.3.1.5 LAN Facilities check.
1) Location – Locate the customer provided LAN connections.
2) Verify IP Address (Site Prep Checklist Appendix B).
3) Verify Connector is an RJ45 (if not contact customer).
4) Connect Laptop and Ping IP Address.
5) Prepare a site IP addressable device diagram showing the IP address for each
device at the base station site. This diagram is essential for any needed
troubleshooting activities.
6) Post the diagram at the site and return a copy to the customer’s maintenance center
and a copy to the AirWalk customer service center:
AirWalk Customer Service Centre
1830 North Greenville Ave.,
Richardson, Texas 75081
7.2 OneRAN Pilot Station Install Procedures
7.2.1 Install OneRAN Pilot Station Cabinet
Move OneRAN Pilot Station to location.
Secure OneRAN Pilot Station in designated location
(Bolt down or Secure Wheels if provided).
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 27 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7.2.2 External System Connections 5
To install new internal connections refer to the Section and Figures in the following Table
for proper cable installation.
Section
Description
Reference
6.1
External Diversity Antenna System
Figure 6-2
Figure 6-3
6.2
Electrical Power Cable
Use AC power
cables supplied
with unit.
6.3
6.4
External BSC & BTS Ethernet Cable
External GPS Antenna Cable
Figure 6-4
Figure 6-5
Table 7-1 - External System Cable Reference
7.2.3 Connect Power to Cabinet
Connect -48VDC to DC distribution panel (if applicable).
Connect 120VAC or 240VAC to Rack AC distribution panel (if applicable).
7.2.4 Connect Communications Facilities
Connect LAN Facilities to BSC
Connect LAN Facilities to BTS.
7.2.5 Power-up procedure 6 7
7.2.5.1 Power-up Main cabinet
Make sure all appropriate LED’s are illuminated.
7.2.5.2 Complete any Configuration options.
a) Configure the OneRAN Pilot Station.
i)
Outgoing and incoming channels.
WARNING: Make sure all system power supplies are turned off. All
breakers/Fuses are pulled on all main and intermediate panels. Then proceed with
the Installation.
Note: Once all connections are made, make sure to: Reset/install all breakers/fuses for
all main and intermediate breaker/fuse box(s). Then proceed with the Installation.
Make sure all added cabling is tie-wrapped correctly
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 28 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7.3 System Test
This section contains the system tests that should be completed to determine if the
OneRAN Pilot Station is operational.
7.3.1 PC to OneRAN Pilot Station cable
A special cable is required to run the required certification tests.
Connect a PC with the subject cable to run tests
RJ1
Pin Configuration
P1
RJ-45
10
10
BTS
DB9
(Computer)
RJ-45
(BTS)
CONNECTOR DB9
Figure 7-1 - PC to OneRAN Pilot Station Cable Specifiaction
Figure 7-2 - PC to OneRAN Pilot Station Cable Connection Diagram
7.3.2 System Certification Tests
Start The OneRAN Pilot Station tests.
This sequence of test cases is designed to certify the OneRAN Pilot Station installation.
It is assumed the person running this checklist is familiar with the basics of configuring,
running, stopping, and starting the OneRAN Pilot Station.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 29 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7.3.2.1 Test Case #1 - Image/PLD loading
7.3.2.1.1 Test Procedure #1
•
Command:
user: ipbs001
FTP password: ipbs001
•
Command:
Edit:
- P: display
- C: edit
7.3.2.1.2 Expected Result of Case #1
Screen from PC using ftp Server is shown in Figure 7-3.
Figure 7-3 - Screen from PC Screen from WPM
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 30 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Figure 7-4 - Screen from PC
7.3.2.2 Test Case #2 – System Check
7.3.2.2.1 Test Procedure #2
•
Command: Version
7.3.2.2.2 Expected Result of Case #2
Figure 7-5 - Version Command Screen
7.3.2.3 Test Case #3 – Tx check
7.3.2.3.1 Test Procedure #3
•
Command: txReason
•
Expected Result of Case #3
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 31 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Figure 7-6 - Tx Check Screen
7.3.2.4 Test Case #4 – Output power
7.3.2.4.1 Test Procedure #4 – RF Check
•
Command: showRfGain
7.3.2.4.2 Expected Result of Case #4
Figure 7-7 - RF Check Screen
7.3.2.5 Test Case #5 – GPS Check
7.3.2.5.1 Test Procedure #5
•
Command: gpsStatus
7.3.2.5.2 Expected Result of Case #5
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 32 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Figure 7-8 – GPS Status Check Screen
Figure 7-9 - GPS Alarm Check Screen
7.3.2.6 Test Case #6 – BTS Alarm Check
7.3.2.6.1 Test Procedure #6
•
Command: showAlarm
7.3.2.6.2 Expected Result of Case #6
Figure 7-10 - BTS Alarm Check Screen
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 33 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7.3.2.7 Test Case #7 – System Reset
7.3.2.7.1 Test Procedure #7
•
Command: btsReset/bscReset/allReset
7.3.2.7.2 Expected Result of Case #7
The system is RESET
7.3.2.8 Test Case #8 – PN Check
7.3.2.8.1 Test Procedure #8
•
Command: RcmCmd 1,1
7.3.2.8.2 Expected Result of Case #8
Figure 7-11 - PN Check Screen
7.3.2.9 Test Case #9 – System Interface Check
7.3.2.9.1 Test Procedure
•
Command: Ping
Send Ping Command to the Following system IP Addresses
1. WPM (Wireless PBX Manager)
2. PDSN (Packet Data Serving Node)
3. CA (Call Agent)
4. MG (Media Gateway)
5. SG (Signal Gateway)
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 34 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7.3.2.9.2 Expected Result of Case #X
A successful PING command response should be received from each system.
7.3.3 Operation Tests
These test cases are designed to determine if OneRAN Pilot Station is ready for
production testing.
7.3.3.1 Test Case #1 – Voice Calls
7.3.3.1.1 Test Procedure
Test Call from MS #1 to MS #2.
Test Call from MS #1 to Landline Phone #1.
7.3.3.1.2 Excepted Result of Case #1
1. 2nd MS Rings and call is answered
2. Landline phone Rings and call is answered.
7.3.3.2 Test Case #2 – Data Calls
7.3.3.2.1 Test Procedure
1. A Test Data Call from MS #1 to MS #2.
2. A Test Data Call from MS #2 to MS #1.
7.3.3.2.2 Excepted Result of Case #2
1. A Data Session is established between MS #1 and MS #2.
2. A Data Session is established between MS #2 and MS #1.
7.3.4 Operator Specific Tests
These test cases are covered in a separate test plan document and are agreed to by the
operator and AirWalk Communications, Inc.
7.4 Site Clean up and Customer Signoff
7.4.1 Dispose of all packing material.
Make sure to dispose of all OneRAN Pilot Station packing material.
7.4.2 Clean-up site
Make sure not to leave anything but the installed OneRAN Pilot Station. (e.g., excess tiewraps, bolts, etc).
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 35 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
7.4.3 Update Installation Checklist.
Make sure all changes are notes on Installation Checklist.
7.4.4 Customer Signoff
Get Customer Signature on Certification Document Appendix D.
7.5 Required Tools and Supplies
1) Hand Tools
a) Screwdriver set,
b) Pliers set,
c) Nut Driver set,
d) Cutter set,
e) Punch Down Tool,
f)
Wire-wrap (Optional),
g) RJ-45 Crimper.
2) Test Equipment.
a) Multi-Meter & Adapter kit,
b) Cable Tester,
c) Protocol Analyzer & Adapter kit,
d) Telephone Test Set (Butt-set),
e) Set of Banjo adapters
f)
Tone Generator & Inductive pick-up.
3) Supplies.
a) RJ-45,
b) Cat 5 Cable,
c) Tie-wraps.
7.6 Troubleshooting Procedures
The OneRAN Pilot Station is designed to provide reliability and consistently high
performance in all network environments. The installation procedure for the OneRAN
Pilot Station is a straightforward and is discussed in these sections.
Should problems develop during installation, this section is intended to help locate,
identify and correct these types of problems. Please follow the suggestions listed below
prior to contacting AirWalk Communications, Inc. or Carrier contacts. If you are unsure of
the procedures described in this section, contact the Installation coordinator immediately.
7.6.1 Before Calling for Assistance
1) If difficulty is encountered with a specific component of the OneRAN Pilot Station,
refer back to the Installation Section for that component.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 36 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
2) Check the cables and connectors to ensure that they have been properly connected
and the cables/wires have not been crimped or impaired in some way during
installation. (About 90% of component problems can be attributed to wiring and
connector problems).
a) Check Cable,
b) Check connector,
c) Check for solid connection,
d) Check with Carrier contact.
3) Make sure that all power cord is properly attached to each OneRAN Pilot Station
component. Be certain that all power cords are plugged into a functioning electrical
outlet. Use the PWR LED’s to verify each unit is receiving power.
a) Check intermediate breakers or fuses.
4) If the problem is isolated to something other than the OneRAN Pilot Station contact
the appropriate Carrier contact person.
5) Verify whether or not the problem is corrected. If not, go to Step 6 below. If the
problem is corrected, continue with installation.
6) If the problem continues after completing Step 4 above, contact the AirWalk
Communications, Inc. Installation Project manager, to determine the next course of
action.
7.6.2 When Calling for Assistance
Please be prepared to provide the following information.
1) A complete description of the problem, including the following points:
a) The nature and duration of the problem;
b) Situations when the problem occurs;
c) The components involved in the problem;
d) Any particular application that, when used, appears to create the problem;
2) A record of changes that have been made to the OneRAN Pilot Station configuration
prior to the occurrence of the problem.
3) Any changes to system should all be noted.
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 37 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
8 Appendix A - Acronyms
Acronym
2G
3G
AC
Access
Channel
ACH
AD
AFEU
AGC
ANT
AWGN
Base Station
(BS)
BCCM
BHCA
BLK
BS
BSAP
BSC
BSMAP
BTS
CA
CAI
CC
CCM
CDMA
CEC
CED
CLAP
CPIB
CPU
CR
CREF
CSM5000
DA
DC
DCCH
DCLI
DRS
DT
DTAP
Description
Second Generation in CDMA wireless network
Third Generation in CDMA wireless network
Alternating Current
A Reverse CDMA Channel used by mobile stations for communicating to the
base station. The Access Channel is used for short signaling message
exchanges, such as call originations, responses to pages and registrations. The
Access Channel is a slotted random access channel.
Access Channel
Analog to Digital
Antenna Front End Unit
Automatic Gain Control
Antenna
Additive White Gaussian Noise
A fixed station used for communicating with mobile stations. Depending upon
the context, the term base station may refer to a cell, a sector within a cell, an
MSC, or other part of the wireless system.
BTS Call Control Module
Busy Hour Call Attempts
Blank
Base Station
Base Station Application Part
Base Station Controller
Base Station Management Application Part
Base station Transceiver Subsystem
Call Agent
Common Air Interface
Connection Confirm
Channel Control Module in BTS
Code Division Multiple Access
Channel Elements Control Block
Channel Elements Diagnostic Block
Composite Link Analysis Platform
BTS Channel and Call Processing Interface Board
Central Processing Unit
Connection Request
Connection Refused
Cell Site Modulator 5000 (CDMA ASIC chip released by Qualcomm for
cdma2000)
Digital to Analog
Direct Current
Dedicated Control Channel
Data Link Connection Identifier
Data Ready to Send
Data Form
Direct Transfer Application Part
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 38 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Acronym
EMI
ESN
EVDO
EVDV
EVRC
FA
FCC
F-CCH
FCH
F-DCCH
FDCH
FER
FM
FO
Forward
Traffic
Channel
FSCH
GND
GPS
GRE
HLR
HO
HPAU
IF
IMSI
ING
IOS
IP
IPC
LAC
LPA
LTU
MAC
MAHHO
MCC
MG
MIMO
MIN
MMC
MMS
MN
MS
MSC
Description
Electro-Magnetic Interference
Electronic Serial Number
Evolution Data Only
Evolution Data and Voice
Enhanced Variable Rate CODEC
Frequency Assignment
Federal Communications Commission
Forward Common Control Channel
Fundamental Channel
Forward Dedicated Control Channel
Forward Dedicated Signaling Logical Channel
Frame Error Rate
Fault Management
Frame Offset
One or more code channels used to transport user and signaling traffic from the
base station to the mobile station.
Forward Common Signaling Logical Channel
Ground
Global Positioning System
Generic Routing Encapsulation
Home Location Register
Handoff
High Power Amplifier Unit
Intermediate Frequency
International Mobile Subscriber Identity
Inter Network Gateway
Interoperability System
Internet Protocol
Inter Processor Communication
Link Access Control.
Entity that provides assured mode or unassured mode delivery of information
across the air interface between the mobile station and the base station.
Linear Power Amplifier
Logical Transmission Unit
One or more Type 3 or Type 5 MuxPDUs with a 16bit CRC.
Medium Access Control
Entity that controls the access to and from Upper Layer Signaling, Data Services
and Voice Services to Physical Layer resources.
Mobile Assisted Hard Hand Off
Main Call Control module in IP-BSC
Media Gateway
Multi Input Multi Output
Mobile Identification Number
Man-Machine Command
Multimedia Messaging Service
Mobile Node
Mobile Station
Mobile Switching Center
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 39 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Acronym
MTBF
MTTR
NDSS
NGN
NMS
OAM
OCNS
OS
OTD
OUNS
PACA
Paging
Channel
PBA
PBX
PCB
PCF
PCH
PCM
PCPM
PDSN
PDU
PER
Physical
Channel
Pilot
Channel
PLD
PN
PSA
PSTN
QCELP
QOF
QOF
QoS
RAN
RC
RCC
RDCH
Reverse
Traffic
Channel
RF
RLC
Description
Mean Time between Failure
Mean Time to Repair
Network Directed System Selection
Next Generation Networks
Network Management System
Operation, Administration, and Maintenance
Orthogonal channel Noise Simulator
Operating System
Orthogonal Transmit Diversity
Other User Noise Source
Priority Access Channel Assignment
A code channel in a Forward CDMA Channel used for transmission of control
information and pages from a base station to a mobile station
Printed Board Assembly
Private Branch Exchange
Printed Circuit Board
Packet Control Function in IP-BSC
Paging Channel
Pulse Code Modulation
Primary BSC Call Processing Board
Packet Data Serving Node
Protocol Data Unit. An atomic set of data, header information, and control
information that are provided by a service user to a service provider.
Packet Error Rate
Radio transmission link
An un-modulated, direct-sequence spread spectrum signal transmitted by a
CDMA base station or mobile station. A pilot channel provides a phase
reference for coherent demodulation and may provide a means for signal
strength comparisons between base stations for determining when to handoff.
Program Loaded Data
Pseudo Noise
Power Supply Assembly
Public Switched Telephone Network
Qualcomm Code Excited Linear Prediction
Quasi-Orthogonal Function
Quasi Orthogonal Function
Quality of Service
Radio Access network
Radio Configuration
Radio interface Call Control
Reverse Dedicated Signaling Logical Channel
A traffic channel on which data and signaling are transmitted from a mobile
station to a base station. The Reverse Traffic Channel is composed of up to one
Reverse Dedicated Control Channel, up to one Reverse Fundamental Channel,
zero to two Reverse Supplemental Channels, and zero to seven Reverse
Supplemental Code Channels.
Radio Frequency
Release Complete
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 40 of 49
OneRAN Pilot Station System Installation Manual
____________________________________________________________________________
Acronym
RLP
RLSD
RP
RPSU
RRCU
RRM
RRP
RRQ
RSCH
RSSI
RTP
RU
RUpd
SAP
SAR
SCCH
SCCP
SCH
SDU
SEU
SIGTRAN
Slotted Mode
SMS
SMV
SRBP
SRU
SS
STS
Sync
Channel
TCC
TCE
TCM
TCP
TOD
TP
TPTL
UART
UDP
VSWR
XCV
XCVR
Description
Radio Link Protocol. Connection-oriented, negative-acknowledgement-based
data delivery protocol.
Released
Radio Network – PDSN
Remote RF Power Supply Unit
Remote RF Control Unit
Radio Resource Management Block
Registration Reply Message
Registration Request Message
Reverse Common Signaling Logical Channel
Received Signal Strength Indication
Real-Time Transport Protocol
Remote RF Unit
Registration Update Message
Service Access Point
Conceptual point at the interface between two adjacent layers where services
are provided to the upper layer and data and protocol information is exchanged
between layers.
Segmentation and Reassembly
Supplemental Code Channel
Signaling Connection Control Protocol
Supplemental Channel
Selection and Distribution Unit
Sector Expansion Unit
Signaling Transport processing module in IP-BSC
An operation mode of the mobile station in which the mobile station monitors
only selected slots on the Paging Channel
Short Message Service
Selectable Mode VOCODER
Signaling Radio Burst Protocol. An entity that provides connectionless protocol
for Signaling messages.
Sector Reduction Unit
Soft Switch
Space Time Spreading
A code channel in the Forward CDMA Channel which transports the
synchronization message to the mobile station
Traffic Channel Control Block
Traffic Channel Element
Traffic Control Module in BTS
Transmission Control Protocol
Time of Day
Traffic processing and Path Control module in IP-BSC
Transmit Power Tracking Loop
Universal Asynchronous Receiver/Transmitter
User Datagram Protocol
Voltage Standing Wave Ratio
Base Station Transceiver Control Block
Transceiver Board
_____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 41 of 49
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________________________________________________
9 Appendix B - Site preparation checklist
OneRAN Pilot Station Site Preparation Check List for:
Site
Prep
Date
Com
Guide
Complete plete
Section
ITEM # Description
Customer Contact & Equipment location
a. Main Contact Customer
1.1.1
b. Other Customer Contacts
1.1.2
1. Power contact
1.1.2
2. Communications Facilities Contact
1.1.2
3. LAN Facilities Contact
1.1.2
4. MSC Security Contact
1.1.2
App. C
AirWalk Series IP-RAN Site Requirements
2.1
a. Space requirements
2.1.1
b. AirWalk Series IP-RAN placement Diagram
2.1.2
c. Installation Location for AirWalk Series IP-RAN Equipment
Complete Site Drawings Appendix B
Power requirements
Information
c. Complete Customer Questions Appendix C
{Customer Name}
2.1.2.1
App. B
2.1.3
___________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 42 of 49
5/6/2008
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________________________________________________
ITEM # Description
Site
Prep
Date
Com
Guide
Complete plete
Section
Information
a. Location
b. Voltage
c. Amps
d. Connector
Security
2.1.3
a. MSC Equipment Room security
b. MSC Equipment room access
Communications Facilities
2.1.3
a. Number of T1 circuits
Connector
Location
LAN Facilities
2.1.3
a. Location
b. Connector
c. Carrier Network IP Address
d. AirWalk Series IP-RAN Component IP Addresses
Other Information
a. Heat dissipation
b. Environmental specifications
2.1.4
___________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 43 of 49
5/6/2008
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________________________________________________
ITEM # Description
Site
Prep
Date
Com
Guide
Complete plete
Section
c. Ambient temperature and humidity
2.1.4.2
d. Dust density
2.1.4.4
e. Altitude
2.1.4.5
f. Air conditioning
2.1.4.6
Information
g. Fire protection
___________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 44 of 49
5/6/2008
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________________________________________________
10
Appendix C - Installation Checklist
OneRAN Pilot Station Site Installation Check List for:
Address
{Customer Name}
Installer Name (s)
Customer Contact (s)
{OneRAN Pilot Station Installation Address}
ITEM
10
11
12
13
14
15
16
Install
Date
Manual
Complete
Section
Description
Verify Customer Contact & Equipment location
Contact Customer
Locate OneRAN Pilot Station Equipment
Locate and verify Floor Space
Uncrate and arrange for packing material disposal
Verify location of all distribution points (main and intermediate)
Power Check
Power Location
Verify Connector
Voltage
Amps
LAN Facilities check
Location
Verify IP Address
Verify Connector
Ping IP Address
Time
Customer
Installer
Contact
Initials
Initials
9.1.1
9.1.1.1
9.1.1.2
9.1.1.3
9.1.2
9.1.3
9.1.3.1
9.1.3.1.1
9.1.3.1.2
9.1.3.1.3
9.1.3.1.4
9.1.3.1.5
9.1.5.1.5
9.1.3.1.5
9.1.3.1.5
9.1.3.1.5
___________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 45 of 49
5/6/2008
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________________________________________________
ITEM
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Install
Date
Manual
Complete
Section
Description
Time
Customer
Installer
Contact
Initials
Initials
Prepare IP addressable device diagram
9.1.3.1.5
Post IP diagram at: i) site; ii) customer; iii) Airwalk Customer Service
9.1.3.1.5
Install OneRAN Pilot Station Cabinet
9.2.1
Move OneRAN Pilot Station to location
9.2.1
Secure OneRAN Pilot Station in designated location
9.2.1
Verify all internal System connections
9.2.2
External System Connections
9.2.3
MAKE SURE ALL SYSTEM POWER SUPPLIES ARE TURNED OFF BEFORE PROCEEDING! ! !
Connect Power to Cabinet
9.2.4
Connect -48VDC to DC distribution panel (If applicable)
9.2.4
Connect 120-240 VAC to AC distribution panel (If applicable)
9.2.4
Connect Communications Facilities
9.2.5
Connect LAN Facilities to BSC
9.2.5
Connect LAN Facilities to BTS
9.2.5
Power-up procedure
9.2.6
Power-up Main cabinet/rack power, check LEDs
9.2.6.1
Complete any configuration options
9.2.6.2
System Certification Tests
9.3.2
Test Case #1 - Image/PLD loading
9.3.2.1
Test Case #2 – System Check
9.3.2.2
Test Case #3 – Tx check
9.3.2.3
Test Case #4 – Output power
9.3.2.4
Test Case #5 – GPS Check
9.3.2.5
Test Case #6 – BTS Alarm Check
9.3.2.6
Test Case #7 – System Reset
9.3.2.7
Test Case #8 – PN Check
9.3.2.8
___________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 46 of 49
5/6/2008
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________________________________________________
ITEM
41
42
43
44
45
46
47
48
Install
Date
Manual
Complete
Section
Description
Test Case #9 – System Interface Check
Operation Tests
Test Case #1 – Voice Calls
Test Case #2 – Data Calls
Operator Specific Tests (If Required)
Site Clean Up & Documentation
Dispose of all packing material
Clean-up site
Update Installation Checklist
Get Customer Signature on Certification Document
Time
Customer
Installer
Contact
Initials
Initials
9.3.2.9
9.3.3
9.3.3.1
9.3.3.2
7.3.4
7.4.1
7.4.2
7.4.3
7.4.4
___________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 47 of 49
5/6/2008
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________
11 Appendix D - Customer Certification Document
Date
Subject:
The subject OneRAN Pilot Station has been certified to be up and running today.
_______________________________________
AirWalk Communications, Inc. (Installation Team)
_______________________________________
Authorized Carrier Representative
__________________
Date
__________________
Date
____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 48 of 49
5/6/2008
OneRAN Pilot Station System Installation Manual
__________________________________________________________________________
This Page Marks End of Document
____________________________________________________________________________
AirWalk Proprietary and Confidential
Page 49 of 49
5/6/2008

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Company                         : AirWalk Communications Inc
Source Modified                 : D:20080506185031
Create Date                     : 2008:05:06 13:55:51-05:00
Creator Tool                    : Acrobat PDFMaker 8.1 for Word
Modify Date                     : 2008:05:06 13:58:10-05:00
Metadata Date                   : 2008:05:06 13:58:10-05:00
Document ID                     : uuid:3e42df19-94c1-4649-9351-d4c7a4e67e25
Instance ID                     : uuid:87d5c546-1358-4a52-b07c-a06dc7b446bd
Subject                         : 7
Format                          : application/pdf
Creator                         : AirWalk Communications Inc
Title                           : Product Specification Document
Page Count                      : 49
Page Layout                     : OneColumn
Author                          : AirWalk Communications Inc
Keywords                        : AW, 96
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R4HAWRCPB4W800

Navigation menu