Airspan Communications 255AS Airsynergy Compact Outdoor Pico Base Station User Manual Additional Statements O2J 255AS

Airspan Communications Limited Airsynergy Compact Outdoor Pico Base Station Additional Statements O2J 255AS

Contents

Additional User Manual Statement

Additional Airsynergy User Manual Statements Airsynergy basestation, FCC ID: O2J-255AS, operating on frequencies 2503-2569 MHz (5 MHz channels) or 2506-2566 MHz (10 MHz channels) Federal Communications Rules for operation in USA The  correct  setting  of  the  following  Base  Station parameters  in  Netspan,  are  critical  to  the correct operation of equipment in compliance with the rules detailed in 47CFR27: • Transmit Power • Transmit Frequency • Channel Bandwidth Any attempt to alter these parameters outside those permitted by the Netspan software or the operator license could be a violation of that license  Transmit Power / Tune-up Transmit power is set using the Netspan management software during install /commissioning. The unit may be set to transmit with a power of up to 30 dBm at each antenna port when connected to cross polarised antenna with maximum gain of 18dBi.  FCC and Industry Canada RF Exposure Requirements FCC Maximum Permissible Exposure (MPE) limits for equipment operating in the frequency range 1500 – 100,000 MHz is 1.0 mW/cm2. Following installation and commissioning, the safe distance from the antenna is the greater of: 20cm Or r cm, where r = √ (PG/4πS) P: power input to antenna(s) in mW  G: numeric gain of antenna relative to isotropic radiator S: power density in mW/cm2 = 1 mW/cm2 The device has two antenna ports, so safe distance from the antenna shall be the greater of: 20 cm or √ (2*PG/4πS) Which gives 20 cm or √ (0.16*P*G) cm.