Airspan Communications SCRT-1-49T SCRT User Manual 641661
Airspan Communications Limited SCRT 641661
Contents
- 1. User Guide
- 2. Page from original user manual
Page from original user manual
General
23
- Install one RF lightning protector between the radio and antenna in series with the RF
cable.
- A lightning arrestor in series with the RF cable at the point of entry to the building.
- Install a lightning arrestor in series with the IF cable at the transceiver on the
tower/mast.
- The AC wall outlet ground for the MacroMAX terminal must be connected to the same
grounding system as the radio and antenna lightning protectors.
1.6 FCC RF Exposure
FCC Maximum Permissible Exposure (MPE) limits for equipment operating in the
frequency range 1500 – 100,000 MHz is 1.0 mW/cm2.
Following installation and commissioning, the safe distance from the antenna is the
greater of:
20cm
Or
r cm, where r = ¥ (PG/4S)
P: power input to antenna in mW = 166mW
G: numeric gain of antenna relative to isotropic radiator
S: power density in mW/cm2 = 1 mW/cm2
Therefore, safe distance from the antenna shall be the greater of
20 cm or ¥ (13.21*G) cm.