Airspan Networks AIRSPAN-IDR Indoor Data Radio (IDR) User Manual Install Guide Part 3
Airspan Networks Inc Indoor Data Radio (IDR) Install Guide Part 3
Contents
Install Guide Part 3
Installing the BSPS Symptom Hardware Installation Guide Possible Cause Remedy between any two modules). • Rectifier(s) are not properly adjusted. • Re-adjust the voltage of the problematic rectifier(s). Battery backup time is too low • Battery is too small for the application. • Increase battery capacity • Charging voltage is too low • Weak battery 7-28 • Raise the system output voltage using the “VOLT ADJ.” • Replace the battery and check ambient temperature according to manufacturer’s instructions Airspan Networks Ltd. 02030311-05 Part II Installing WipLL Customer Premises Equipment Part II describes the procedures for installing the WipLL equipment located at the subscriber’s premises. Part II includes the following chapters: ! Chapter 8, “Installing the SPR” ! Chapter 9, “Installing the SDA” ! Chapter 10, “Installing the IDR” This page is intentionally left blank. 8 Installing the SPR This chapter describes the installation of the WipLL Subscriber Premises Radio (SPR) at the subscriber's premises. This chapter includes the following chapters: ! Overview ! Physical Dimensions and Basic Design ! Cable Guidelines ! Mounting the SPR Minimum Distance between SPRs Wall Mounting Pole Mounting ! Connecting an External Third-Party Antenna (Optional) ! Connecting to the SDA ! Connecting to a PC for Serial Configuration ! Connecting the RSS LED Adapter ! Connecting Power 02030311-05 Airspan Networks Ltd. 8-1 Installing the SPR Hardware Installation Guide 8.1. Overview The SPR receives and transmits data from and to the base station. The SPR connects to the subscriber’s network through the SDA. The SDA is an Ethernet hub/LAN switch (depending on SDA model) that provides the SPR with DC power, lightening protection, and Ethernet (10Base-T and/or 100Base-T )connectivity to the subscriber’s PCs/network (up to four PCs depending on SDA model). The SPR connects to the SDA by a CAT-5 cable. The SPR is typically mounted on the subscriber's roof or external wall; the SDA is installed inside the subscriber's premises. The SPR is available in the following models: ! SPR with Standard Gain: includes a built-in antenna 15-dBi antenna gain, covering an area of 23 degrees ! SPR with High-Gain Antenna: includes a built-in antenna with an 18-dBi antenna gain, covering 15 degrees. ! SPR with External Antenna: includes an N-type connector port for attaching a third-party external antenna. Figure 8-1 displays a typical setup of the SPR and SDA at the subscriber's premises. Note: The SDA can also be installed at a base station that has only one BSR. This SDA replaces the need for the BSDU, and provides power and connectivity to the single BSR. 8-2 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR RF link CAT-5e Subscriber Premises Radio (SPR) located on the roof PC Subscriber Data Adapter (SDA) located inside Figure 8-1: Typical SPR and SDA location and connections at subscriber's premises Warning: As the system emits microwave radiation, a minimum distance of 200 mm must be maintained from the front of the SPR. To avoid electrical or fire hazard, connect the SPR to the power supply only after mounting the SPR and connecting data cables between the SPA and SDA units. Note: Usually, the SPR is initialized (i.e., configured with an IP address) at Airspan's factory. However, if the SPR has not been configured, see Section 8.7, “Connecting to a PC for Serial Configuration”, before mounting the SPR. 02030311-05 Airspan Networks Ltd. 8-3 Installing the SPR Hardware Installation Guide Note: The digital portion of the transceiver has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try correct the interference by performing one or more of the following measures: - Reorientate or relocate the receiving antenna - Increase separation between the equipment and receiver - Connect the equipment to an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help 8-4 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.2. Physical Dimensions and Basic Design The SPR is encased in a chassis and provides access to the SPR’s communication port at the front panel. The SPR’s bottom panel provides holes for mounting the SPR to, for example, a pole or wall (see Figure 8-3). 15-pin D-type port Figure 8-2: SPR (with built-in antennal) The SPR’s physical dimensions are described in Table 8-1 Table 8-1: SPR physical dimensions Parameter SPR model Standard Gain Antenna High Gain Antenna Height 311 mm (12.24 inches) 400 mm (15.74 inches) Width 224 mm (8.82 inches) 317 mm (12.48 inches) Depth 65.5 mm (2.58 inches) 65.5 mm (2.58 inches) Weight 2.5 kg 4.7 kg Notes: 1) The SPR’s physical dimensions exclude the mounting kit. 2) An SPR model with an N-type receptacle for attaching a third-party external antenna is also available (see Section 8.5, “Connecting a Third-Party External Antenna (Optional)”. 02030311-05 Airspan Networks Ltd. 8-5 Installing the SPR Hardware Installation Guide 8.3. Cable Guidelines The following lists cable installation guidelines at the subscriber's premises: ! To prevent tripping, a wiring duct is to be provided at the subscriber's premises to house data cables. Wiring channel type, location, and methods of securing are to be discussed with the subscriber. ! Cables not housed in wiring channel must be dressed in a manner to avoid a trip hazard. Avoid trailing wires across passageways. ! External data cables are to be protected in metal conduit that is to be secured to the building structure in accordance with manufacturers recommendations. ! Outside wiring channels must not be located as to cause a trip hazard (e.g. roof walkways) ! Observe recommended minimum bend radii when installing copper cables. Wherever a cable changes direction, ensure that it does so in a smooth curve with a radius of at least 50 mm in order to prevent damage. ! A maintenance loop is to be left in the cable just before the cable reaches the SPR to prevent strain on the connector. ! Data cables threaded into holes drilled in walls are to be covered by a waterproof sheath to prevent water penetration. ! Silicone sealant should be used to plug any holes on both internal and external wall surfaces once cables are in place. ! All data cables should be labeled with both the source and destination at each end. Un-used cable ends must also be identified with labels to assist with future upgrades. Warning: Cables with exposed ends (i.e., not yet crimped) should be covered with protective polythene bags during external cable installation processes. Note: A minimum separation of 200 mm should exist between power and data cables. 8-6 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.4. Mounting the SPR The SPR can be mounted on a wall or pole. The SPR is mounted using the mounting holes located on the SPR’s bottom panel (see Figure 8-3), and the mounting bracket (provided). The mounting brackets for wall- and pole-mounting are different from one another. Mounting holes Figure 8-3: SPR bottom panel providing holes for mounting 02030311-05 Airspan Networks Ltd. 8-7 Installing the SPR Hardware Installation Guide 8.4.1. Minimum Distance between SPRs A minimum of 3-meter separation is required between mounted SPRs and existing customer radio equipment when not transmitting on the same sector (see Figure 8-4). 3.0 metres Figure 8-4: SPR separation when not transmitting on the same sector A 1-meter separation is required between SPRs when on the same sector and transmitting to the same BSR without requiring shielding (see Figure 8-5). 1.0 metre Figure 8-5: SPR separation when transmitting on the same sector to the same BSR 8-8 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.4.2. Wall-Mounting SPR wall mounting is performed in two chronological stages: ! Attaching the mounting bracket to the SPR’s mounting holes. ! Attaching the mounting bracket (attached to the SPR) to the wall. To mount the SPR on a wall: 1. Attach the mounting bracket to the SPR using two stainless steel bolts, as shown in Figure 8-6. BSR Mounting Bracket BSR Jubilee clip slots 15-pin D-type connector BSR Fixing Bolts Figure 8-6: Attaching the mounting bracket to the SPR 2. Attach the mounting bracket to the wall using four screws. The fixing dimensions for the mounting bracket is illustrated in Figure 8-7. 02030311-05 Airspan Networks Ltd. 8-9 Installing the SPR Hardware Installation Guide 8mm 58mm 99mm Figure 8-7: SPR mounting bracket dimensions for the four fixing holes Note: Airspan does not provide screws for attaching the mounting bracket to the wall. The screw size depends on the structure of the building to which the bracket is to be attached. When selecting screw sizes, consideration must be given to the weight of the SPR and load that may be induced in windy conditions. 8-10 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 3. Adjust the horizontal positioning of the SPR, and then fasten tight the two stainless-steel bolts. Rotation is restricted to the horizontal plane only. The permissible rotation is shown in Figure 8-8. Figure 8-8: Horizontal rotation of the SPR Note: A thread-locking compound is to be used to prevent the bolts working loose. 02030311-05 Airspan Networks Ltd. 8-11 Installing the SPR Hardware Installation Guide 8.4.3. Pole-Mounting The SPR can be mounted on a pole (see Figure 8-9). Pole mounting allows the SPR to be adjusted in the horizontal as well as the vertical plane. The pole-mounting bracket assembly is designed to support the SPR on a round pole of 45 mm in diameter. Figure 8-9: Mounted SPR 8-12 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR To mount the SPR on a pole: 1. Attach the mounting bracket to the SPR using two stainless steel bolts. Locking Holes BSR mounting Bracket Clamping Bracket Pivot Hole ‘U’ Bolt Figure 8-10: SPR mounting bracket assembly 2. Attach the clamping bracket to the mounting bracket using two M8 stainless bolts. 3. Attach the Clamping bracket to the pole by placing the U-bolt around the pole, and then inserting the U-bolt through the Clamping bracket and securing it by screwing the two bolts on the U-bolt. 02030311-05 Airspan Networks Ltd. 8-13 Installing the SPR Hardware Installation Guide 4. Adjust the vertical position of the SPR. Lock the SPR at the desired position by inserting the locking bolt in the desired position. Once the correct angle has been set both bolts must be tightened to lock the SPR bracket in place. 5. Adjust the horizontal position of the SPR by rotating the SPR about the pole, and then tighten the U-bolt. SPR positioning is obtained in two planes by adjustment of the mounting bracket assembly a shown in Figure 8-11. Rotation about the mounting bracket Rotation about the mounting pole Figure 8-11: SPR GPS orientation in vertical (top figure) and horizontal plane (lower figure) Note: A thread-locking compound is to be used to prevent the bolts working loose. A loop should be left in the cable for maintenance purposes and to prevent the cable weight being taken directly on the connector. 8-14 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.5. Connecting a Third-Party External Antenna (Optional) The SPR model with an N-type connector can be connected to an external antenna. The addition of an external antenna allows greater RF sector coverage than the standard SPR internal antenna models (i.e., 60°). ! Connector: N-type male Figure 8-12: Example of an N-type connector ! Cable: RF coaxial Warnings: 1) Before connecting the external antenna, ensure that the SPR is NOT connected to the power source. 2) Before powering on the SPR, ensure that some type of equiment such as an antenna or an RF attenuator is connected to the N-type receptacle. This eliminates the risk of burning the SPR device. 3) It is the responsibility of the person installing the WipLL system to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), that only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance with FCC rules CFR47 part 15.204. The installer should configure the output power level of antennas according to country regulations and per antenna type 02030311-05 Airspan Networks Ltd. 8-15 Installing the SPR Hardware Installation Guide To connect the SPR to an external antenna: ! Attach an N-type male connector of the third-party antenna to the N-type receptacle located on the SPR’s front panel. Figure 8-13: SPR model with N-type connector for attaching an external antenna Note: Airspan supplies unterminated cables for N-type connectors. Refer to Appendix B, “Cable Crimping" for N-type cable crimping. 8-16 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.6. Connecting to the SDA The SPR connects to the subscriber’s PCs/network through the SDA. To connect the SPR to the SDA, you need to connect the SPR’s 15-Pin D-type port to the SDA’s 15-pin D-type port by a CAT-5e cable. The SPR-to-SDA cable connection configurations is as follows: ! Connectors: SPR: 15-pin D-type male (only 8 pins are used) SDA: 15-pin D-type male (only 8 pins are used) Note: Airspan supplies unterminated CAT-5e cables. Refer to the cable crimping procedures for 15-Pin D-type connectors detailed in Appendix B, “Cable Crimping". ! Cable: straight-through 10Base-T Ethernet UTP 4 Pair CAT-5e outdoor type (24 AWG) ! Connector pinouts: Table 8-2: SPR-to-SDA CAT 5 cable connector pinouts 15-pin D-type male 02030311-05 SPR Pin Wire color Function +48 VDC Blue / white -48 VDC Blue Tx+ Orange / white Tx- Orange Rx+ Green / white Rx- Green Sync.+ Brown / white Sync.- Brown Airspan Networks Ltd. Wire pair Pin +48 VDC -48 VDC Rx+ Rx- Tx+ Tx- Sync.+ Sync.- SDA Function 8-17 Installing the SPR Hardware Installation Guide Notes: - Pins 9 through 15 of the 15-pin D-type connector are not used. - The wire color-coding described in the table is WipLL's standard for wire color-coding. However, if you implement your company's wire color-coding scheme, ensure that the wires are paired and twisted according to the pin functions listed in Table 8-2 (e.g., Rx+ with Rx-). WipLL uses the following wire color-coding standards for CAT 5 cables with 15-pin D-type to 15-pin D-type connectors on either ends (8 wires used): Figure 8-14: WipLL wire color-coding for 15-pin D-type connectors 8-18 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR Notes: 1) The wires are twisted together in pairs, for example, blue/white with blue, and orange/white with orange. This prevents electrical interference between the transmitter pins. For example, pin 3 (Tx+; orange / white) is paired and twisted with pin 4 (Tx-; orange). 2) The SDA connector pinouts are the same for all SDA models (SDA-1, SDA4H, SDA-4S, SDA-4S/VL, SDA-4S/Vltag, SDA-4S/1H3L, and SDA4S/VL/1H3L). Warning: To avoid electrical shock, before connecting the SPR to the SDA, ensure that the SDA is not connected to the power supply. To connect the SPR to the SDA: 1. Attach the 15-pin D-type connector, at one end of the cable, to the SPR’s 15-pin D-type port labeled DATA POWER SYNC, as displayed in Figure 8-15. 2. Attach the 15-pin D-type connector, at the other end of the cable, to the SDA’s 15-pin D-type port, as displayed in Figure 8-15. 02030311-05 Airspan Networks Ltd. 8-19 Installing the SPR Hardware Installation Guide Figure 8-15: SPR-to-SDA cable connections Note: The maximum cable length permissible between the SPR and SDA is 100 meters. 8-20 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.7. Connecting to a PC for Serial Configuration To configure an SPR, you need to connect a PC running the WipLL network management system (WipConfig) to the SPR. The SPR’s 15-pin D-type port provides serial interface to a PC for SPR initial configuration. This port uses 9 of its 15 pins for serial interface; the remaining pins are used for interfacing with the SDA with which the SPR remains connected. To connect the SPR to the management station (i.e., PC) and the SDA, a Y-cable (splitter) is used. Note: SPR configuration is performed while the SDA is connected to the SPR. The SPR-to-PC and SDA cable connections for SPR serial configuration are as follows: ! Connectors: SPR: 15-pin D-type male (only 9-pins used) PC: 9-pin D-type (RS-232) SDA: 15-pin D-type male ! Cable: straight-through Y-cable PC 9-pin D-type female SPR 15-pin D-type male 15-pin D-type male SDA Figure 8-16: Y-cable for serial connection 02030311-05 Airspan Networks Ltd. 8-21 Installing the SPR Hardware Installation Guide ! Connector pinouts: Table 8-3: Y-cable SPR-to-SDA connector pinouts SPR 15-pin D-type male SDA Pin Function Pin Function 0 VDC +48 VDC +48 VDC -48 VDC Ethernet Tx+ Rx+ Ethernet Tx- Rx- Ethernet Rx+ Tx+ Ethernet Rx- Tx- Hop Sync+ Sync.+ Hop Sync- Sync.- 15-pin D-type male Table 8-4: Y-cable SPR-to-PC connector pinouts SPR 15-pin D-type male 8-22 Pin PC Function Pin Function 12 GND GND 14 RS232 Rx Rx 15 RS232 Tx Tx Airspan Networks Ltd. 9-pin D-type female 02030311-05 Hardw are Installation Guide Installing the SPR The Y-cable connector pin assignments are displayed shematically in Figure 8-17. Figure 8-17: Y-cable connector pin assignment To connect the SPR to a PC for serial configuration: 1. Connect the 15-pin D-type male connector (P1), at the one end of the Y-cable, to the SPR, as displayed in Figure 8-18. 2. Connect the 15-pin D-type male connector (J1), at the other end of the Y-cable, to the SDA, as displayed in Figure 8-18. 3. Connect the 9-pin D-type (RS232) connector (J2), at the other end of the Ycable, to the PC, as displayed in Figure 8-18. 02030311-05 Airspan Networks Ltd. 8-23 Installing the SPR Hardware Installation Guide Figure 8-18: SPR cable connections for serial configuration Note: For performing SPR initial configuration using WipLL’s management applications, refer to Airspan’s WipConfig User’s Guide or WipConfig PDA User’s Guide. 8-24 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.8. Connecting the RSS LED Adapter The WipLL RSS LED adapter indicates the received signal strength (RSS) between the SPR and the BSR. This allows you to accurately position the SPR during installation for optimal radio frequency signal reception. The RSS LED adapter is connected between the SPR and SDA CAT 5 cable connection. The RSS LED adapter provides two 15-pin D-type ports: one for the SPR side; and the other for the SDA side. The RSS LED adapter can be connected in one of the following manners: ! The RSS LED adapter 15-pin D-type port connects directly to the SPR’s 15-pin D-type port; while the other RSS LED adapter’s 15-pin D-type port connects to the SDA via the CAT 5 cable. -Or! Both 15-pin D-type ports of the RSS LED adapter connect to the SPR and SDA via a CAT 5 cable on either side. The following describes the connectors, cable, and connector pinouts: ! Connectors: SPR: 15-pin D-type male (only 9-pins used) RSS LED adapter: − SPR side: 15-pin D-type female − SDA side: 15-pin D-type male SDA: 15-pin D-type male ! Cables: two straight-through cables for SPR-to-RSS LED adapter, and for SDAto-RSS LED adapter. 02030311-05 Airspan Networks Ltd. 8-25 Installing the SPR Hardware Installation Guide To connect the RSSI LED adapter: 1. Connect the 15-pin D-type male connector, at one end of the straight-through cable, to the SPR, as displayed in Figure 8-19. 2. Connect the 15-pin D-type female connector, at the other end of the straightthrough cable, to the RSS LED adapter, as displayed in Figure 8-19. 3. Connect the 15-pin D-type male connector, at one end of the straight-through cable that originates from the SDA, to the RSS LED adapter, as displayed in Figure 8-19. 8-26 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR Figure 8-19: Connecting the RSS LED adapter 02030311-05 Airspan Networks Ltd. 8-27 Installing the SPR Hardware Installation Guide Note: You can connect the RSS LED adapter’s 15-pin male port directly to the SPR’s 15-pin port, instead of using a cable. Table 8-5 describes the LEDs on the RSS LED adapter. Table 8-5: LED description of the RSS LED adapter LED Power RSS LEDs (LEDs 0 to 7) 8-28 Color Red Green Function Power Received Signal Strength level Status Description On The SPR receives power from the SDA Off No power is supplied to the SPR by the SDA Blinking Data transmission is occurring on the Ethernet LAN LED 1 blinking RSS ≤ -94 dBm LED 1 is on -93 dBm ≤ RSS ≤ -90 dBm LEDs 1 and 2 are on -89 dBm ≤ RSS ≤ -86 dBm LEDs 1, 2, and 3 are on -85 dBm ≤ RSS ≤ -82 dBm LEDs 1, 2, 3, and 4 are on -81 dBm ≤ RSS ≤ -78 dBm LEDs 1, 2, 3, 4, and 5 are on -77 dBm ≤ RSS ≤ -74 dBm LEDs1, 2, 3, 4, 5, and 6 are on -73 dBm ≤ RSS ≤ -70 dBm LEDs 1, 2, 3, 4, 5, 6 and 7 are on -69 dBm ≤ RSS ≤ -66 dBm All LEDs are on RSS ≥ -65 dBm Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SPR 8.9. Connecting Power The SPR receives, through its 15-pin D-type port, its power supply from the SDA. In turn, the SDA connects to an external power adapter from where it receives power. The SDA provides 48 VDC nominal power to the SPR (minimum of 30 VDC: maximum of 55 VDC). Warning: If you are using an external antenna, ensure that you connect the antenna before connecting the SPR to the power source. Note: For a description of the procedure for connecting power to the SDA, see Chapter 9, “Installing the SDA”. 02030311-05 Airspan Networks Ltd. 8-29 9 Installing the SDA This chapter describes the installation of the WipLL Subscriber Data Adapter (SDA) at the subscriber's premises. This chapter includes the following chapters: ! Overview ! Physical Dimensions and Basic Design ! Mounting the SDA Desktop-Mounting Wall-Mounting ! Connecting to the SPR ! Connecting to the Subscriber’s Ethernet Network Connecting to PCs Connecting to a Hub Connecting to a VoIP Network ! Connecting AC Power ! LED Display SDA-4H SDA-4S Models 02030311-05 Airspan Networks Ltd. 9-1 Installing the SDA Hardware Installation Guide 9.1. Overview The SDA is an Ethernet hub/LAN switch that provides the SPR with DC power, lightening protection, and Ethernet connectivity to the subscriber’s PCs/network. The SDA connects to the SPR by a CAT-5 cable. The SDA provides 10/100BaseT connectivity (depending on the SDA model) to the subscriber’s PCs or network (up to four PCs depending on the SDA model). The SDA is located inside the subscriber's premises, typically mounted on a wall or simply placed on a desktop. The SDA is available in six models: ! SDA-1: This is a hub that provides one 10BaseT interface (RJ-45 port) with the subscriber’s PC and/or network (via a hub or LAN switch). ! SDA-4H: This is a hub and provides four 10BaseT ports for interfacing with the subscriber’s PCs/network. In addition, one of the 10BaseT ports provides crossover configuration for crossover-cable connection for interfacing with, for example, other hubs. ! SDA-4S models: Integrated LAN switches, providing four 10/100BaseT interfaces with the subscriber’s PCs/network. The ports of the SDA-4S models support Auto Negotiation, allowing automatic configuration for the highest possible speed link: 10BaseT or 100BaseT, and Full Duplex or Half Duplex mode. In other words, the speed of the connected device (PC) determines the speed at which packets are transmitted through the specific port. For example, if the device (i.e, PC) to which the port is connected is running at 100 Mbps, the port connection will transmit packets at 100 Mbps. If the device (i.e, PC) to which the port is connected is running at 10 Mbps, the port connection will transmit packets at 10 Mbps. In addition, the SDA-4S ports support MDI/MDIX automatic crossover, allowing connection to straight-through or crossover CAT-5 cables 9-2 SDA-4S (standard): Standard integrated LAN switch, providing four 10/100BaseT interfaces to the subscriber’s computers. Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA SDA-4S/VL: Provides VLANs between its ports and the SPR, ensuring privacy between users of different ports (i.e., multi-tenant VLAN security). For example, all users connected to Port 1 do not “see” users connected to Port 2. SDA-4S/VLtag: This model is ideal for multi-tenant applications where traffic engineering and privacy is required. SDA-4S/VLtag assigns the traffic from each of its four ports with a different VLAN ID. The VLAN IDs are fixed (since SDA-4S/VLtag is not user configurable). SPR converts the four VLAN IDs tagged by SDA-4S/VLtag to four VLAN IDs configured via WipLL’s NMS. The tag conversion is performed by SPR before sending the traffic to the air and the other way around when coming from the air. SDA-4S/1H3L: Provides a high priority port (left-most port) for VoIP traffic. SDA-4S/VL/1H3L: Combines the functionality of the SDA-4S/VL and SDA-4S/1H3L models (VLAN for each port and a high priority port for VoIP). Figure 9-1 displays a typical setup of the SPR and SDA at the subscriber's premises. Note: The SDA can also be installed at a base station that has only one BSR. This SDA replaces the need for the BSDU, and provides power and connectivity to the single BSR. 02030311-05 Airspan Networks Ltd. 9-3 Installing the SDA Hardware Installation Guide RF link CAT-5e Subscriber Premises Radio (SPR) located on the roof PC Subscriber Data Adapter (SDA) located inside Figure 9-1: Typical SPR and SDA location and connections at subscriber's premises 9-4 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA 9.2. Physical Dimensions and Basic Design The SDA is encased in a chassis. The chassis front panel provides access to the SDA’s communication ports. The left-side of the chassis provides a power connector port for connection to an external power adapter. The SDA’s bottom panel provides holes for mounting the SDA on a wall Figure 9-2 displays the SDA-4S models and the SDA-4H. 15-pin D-type port Power connector port 10/100BaseT ports Figure 9-2: SDA-4S models and SDA-4H (front, side, and top panels) 02030311-05 Airspan Networks Ltd. 9-5 Installing the SDA Hardware Installation Guide Figure 9-3 displays the SDA-1 model. 15-Pin D-type port Power connector port RJ-45 port (10BaseT) Figure 9-3: SDA-1 (front, side, and top panels) The SDA’s physical dimensions are described in Table 9-1 Table 9-1: SDA physical dimensions Parameter 9-6 Value Height 200 mm (7.87 inches) Width 150 mm (5.9 inches) Depth 40 mm (1.57 inches) Weight 0.53 kg Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA 9.3. Mounting the SDA The SDA can be wall or desk mounted. 9.3.1. Desktop-Mounting For desk mounting (horizontal mounting), the chassis’ bottom panel provides four rubber feet on each corner. Warning: For desk mounting, do not place the SDA on a carpeted surface where airflow is restricted and a fire hazard may result. Mounting brackets Rubber feet Figure 9-4: SDA - rear panel 02030311-05 Airspan Networks Ltd. 9-7 Installing the SDA Hardware Installation Guide 9.3.2. Wall-Mounting For SDA wall mounting, two mounting hooks are molded into the chassis’ bottom panel (see Figure 9-4). The dimensions of the SDA’s wall-mounting hooks, located on the chassis bottom panel, are displayed in Figure 9-5. 5 mm 59 100 Figure 9-5: SDA mounting footprint details Notes: 1) Airspan does not supply screws for wall mounting as the size and type of screws depends on the type of wall at the subscriber’s premises 2) For reasons of safety both fixing points must be utilized when mounting the unit. 3) The SDA is supplied with a 1-metre AC power lead assembly. Therefore, the unit must be located within reachable distance of the customer's mains power outlet. 4) The cable must be dressed tidily and not be taught or pose a trip hazard when connected. 5) The maximum cable run between an SDA and an SPR is 100 meters. 9-8 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA 9.4. Connecting to the SPR The SDA’s 15-pin D-type port connects to the SPR’s 15-pin D-type port by a CAT5 cable. Note: For a detailed description on connecting the SDA to the SPR, see Chapter 8, “Installing the SPR”. 9.5. Connecting to the Subscriber’s Ethernet Network The SDA provides RJ-45 port(s) for Ethernet connectivity to the subscriber’s PCs/network. The number of Ethernet ports and the speed of the Ethernet connection depend on the SDA model. Table 9-2 describes the number of ports and transmission speeds supported by the various SDA models. Table 9-2: Number of ports and transmission speed of SDA models SDA Model RJ-45 Ports Speed (Mbps) SDA-1 10 SDA-4H 10 SDA-4S models (SDA-4S; SDA-4S/VL; SDA-4S/Vltag; SDA4S/1H3L; SDA-4S/VL/1H3L) 10/100 02030311-05 Airspan Networks Ltd. 9-9 Installing the SDA Hardware Installation Guide The following list describes the location of the Ethernet ports for the various SDA models: ! SDA-1: one RJ-45 port (see Figure 9-6) RJ-45 port Figure 9-6: SDA-1 with one Ethernet port ! SDA-4H: four RJ-45 ports (see Figure 9-7). Note: The left-most port (J5) is a crossover port. R-J45 connector (J5) - cross over R-J45 connector (J4) R-J45 connector (J3) R-J45 connector (J2) D-type connector (J1) Figure 9-7: SDA-4H with four Ethernet ports 9-10 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA ! SDA-4S models (SDA-4S, SDA-4S/VL, SDA-4S/Vltag, SDA-4S/1H3L, and SDA-4S/VL/1H3L): four 10/100BaseT RJ-45 ports. These ports support 10/100 Mbps autonegotiation, and MDI/MDI-X automatic crossover. This allows you to connect straight-through or crossover CAT-5 cables to these ports. 10/100BaseT RJ-45 ports Figure 9-8: SDA-4S RJ-45 Ethernet Ports 02030311-05 Airspan Networks Ltd. 9-11 Installing the SDA Hardware Installation Guide 9.5.1. Connecting to PCs The SDA connects to the subscriber’s PC(s) through the SDA’s Ethernet port (RJ-45). Note: To avoid electrical or fire hazard, ensure that the data connections to the SDA is made prior to connecting the power supply. The SDA-to-subscriber PC cable configurations are as follows: ! Connector: 8-pin RJ-45 ! Cable: straight-through Ethernet cable ! Connector Pinouts: RJ-45: SDA-1, SDA-4H (J2, J3, J4), SDA-4S Pin RJ-45 crossover cables: SDA-4H (J5) Function +RX -RX +TX NC NC -TX NC NC Pin Function +Tx -Tx +Rx NC NC -Rx NC NC To connect the SDA to the subscriber’s PC(s): 1. Connect the 8-pin RJ-45 male connector, at the one end of the Ethernet cable, to the SDA’s RJ-45 Ethernet port (see Figure 9-9). 2. Connect the 8-pin RJ-45 male connector, at the other end of the Ethernet cable, to the subscriber’s PC (or device). (See Figure 9-9.) 9-12 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA Figure 9-9: SDA-to-PC Cable Connections Note: The SDA-4S RJ-45 ports support MDI/MDI-X automatic crossover. This means that straight-through or crossover CAT-5 cables can be connected to these ports. 02030311-05 Airspan Networks Ltd. 9-13 Installing the SDA Hardware Installation Guide 9.5.2. Connecting to a Hub The SDA-4S models and SDA-4H can be connected to another hub (for example, for daisy chaining). The ports of the SDA-4S models support MDI/MDI-X automatic crossover, allowing connection of straight-through or crossover cables. However, for the SDA-4H model, only the left-most RJ-45 port (J5) is a crossover port (see Figure 9-7). The SDA-4S and SDA-4H cable configurations for connectivity to a hub, are as follows: ! Connector: 8-Pin RJ-45 ! Cable: SDA-4H: crossover-cable SDA-4S models: straight-through or crossover cables (due to MDI/MDI-X ports) ! Connector pinouts: SDA-4H: SDA-4H RJ-45 (J5) Pin Function +TX -TX +RX NC NC -RX NC NC To connect SDA-4S or SDA-4H to a hub: 1. Connect the RJ-45 male, at one end of the cable, to the SDA-4H’s left-most RJ45 port (J5), or any SDA-4S’s RJ-45 port. 2. Connect the RJ-45 male, at the other end of the cable, to the hub. 9-14 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA Figure 9-10: SDA-4H crossover cable connections to hub 02030311-05 Airspan Networks Ltd. 9-15 Installing the SDA Hardware Installation Guide Figure 9-11: SDA-4S crossover/straight-through cable connections to hub Note: The SDA-4S RJ-45 ports support MDI/MDI-X automatic crossover. Therefore, crossover CAT-5 cables can be connected to any of the ports. 9-16 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA 9.5.3. Connecting to a VoIP Network The SDA-4S/1H3L and SDA-4S/VL/1H3L model’s left-most RJ-45 Ethernet port assigns high priority to VoIP trafic. This port is used to connect to the subscriber’s VoIP network. This port assigns high priority to VoIP traffic, as opposed to the other RJ-45 ports, which assigns lower priority. The cable connections for connecting the SDA-4S/1H3L and SDA-4S/VL/1H3L models to the subscriber’s VoIP network, are as follows: ! Connector: 8-pin RJ-45 male ! Cable: straight-through or crossover ! Connector pinouts: RJ-45 (left-most port) Pin Function +RX -RX +TX NC NC -TX NC NC To connect to the VoIP network: 1. Connect the RJ-45 male connector, at the one end of the Ethernet cable, to the left-most RJ-45 port on the front panel of the SDA-4S/1H3L and SDA4S/VL/1H3L chassis (see Figure 9-12). 2. Connect the RJ-45 male connector, at the other end of the cable, to the VoIP network, for example, to a Residential Gateway (see Figure 9-12). 02030311-05 Airspan Networks Ltd. 9-17 Installing the SDA Hardware Installation Guide Figure 9-12: Connecting VoIP RJ-45 Port (for SDA-4S/1H3L and SDA-4S/VL/1H3L) 9-18 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA 9.6. Connecting AC Power The SDA receives AC power by connecting to a standard 110–240 VAC wall outlet. In turn, the SDA provides 48 VDC nominal power to the SPR (minimum of 30 VDC: maximum of 55 VDC). Table 9-3 lists the SDA power supply specifications. Table 9-3: SDA Power Supply Specifications Power parameter Units Voltages 110-240 VAC Frequency 50/60 Hz Amps 0.3-0.7A The following lists the cable connection between the SDA and the power outlet:. ! Connector: AC IEC 320 type (female) Figure 9-13: Power Chord ! Cable: 3-core 0.7mm² type (maximum length is 1.5 m) For all SDA models, the power port is located on the left-panel of the chassis, as displayed in Figure 9-14 for SDA-1, and in Figure 9-15 for SDA-4H and SDA-4S models. 02030311-05 Airspan Networks Ltd. 9-19 Installing the SDA Hardware Installation Guide Power port Figure 9-14: Location of SDA-1 power port Power port Figure 9-15: Location of SDA-4S model’s and SDA-4H power port 9-20 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA Warning: Ensure that plugs fitted to mains power leads for subscriber premises equipment are compatible with AC mains sockets. Do not replace plugs on power leads to suit local requirements without first verifying grounding practice for the country and equipment in question. Careful consideration must be given to issues including local wiring requirements, cable color-coding, safety grounding, and circuit protection requirements. Prior to connecting to the power outlet, the following pre-connection inspection should be performed on power sockets: ! Power socket shall be visually inspected to ensure that no other equipment is connected to the power outlet. ! No damage to the power outlet. ! No water or dampness on or around the power outlet. ! The power outlet shall be checked using a proprietary plug tester such as a “Martindale Ze” type. Checks are required to verify the earth loop impedance value and the presence of phase, neutral, and earth connections. Note: To avoid electrical or fire hazard, ensure that the data connections to the SDA is made prior to connecting the SDA to the power supply. To connect the SDA to AC power supply: 1. Plug the power plug female, at the end of the AC power chord, into the power plug male located omn the left of the SDA chassis (see Figure 9-16). 2. Plug the power plug male, at the other end of the AC power chord, into the wall power outlet (110-240 VAC). (See Figure 9-16.) 3. Verify that the power is received by the SDA by checking that the POWER LED light (green) is on. 02030311-05 Airspan Networks Ltd. 9-21 Installing the SDA Hardware Installation Guide Figure 9-16: SDA power cable connections 9-22 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA 9.7. LED Display The SDA-4H and SDA-4S models provide LED indicators that indicate network connection, traffic status, and power. These LEDs are located on the top panel of the chassis. 9.7.1. SDA-4H Figure 9-17 displays the location of the SDA-4H LED indicators. Ethernet LEDs (2, 3, and 4) (straight-through) CROSS (5) LED UPLINK (1) LED POWER LED Figure 9-17: SDA-4H LED indicators 02030311-05 Airspan Networks Ltd. 9-23 Installing the SDA Hardware Installation Guide Table 9-4 describes the SDA-4H LED indicators. Table 9-4: Description of the SDA-4H LED Indicators LED Color 1 (UPLINK) Yellow 2, 3, and 4 5 (CROSS) POWER 9-24 Yellow Yellow Green Status Meaning On Physical link between SDA-4H and SPR Blinking Traffic flow between SDA-4H and SPR Off No link between SDA-4H and SPR On Physical link between SDA-4H and Ethernet network Blinking Traffic flow between SDA-4H and Ethernet network Off No link between SDA-4H and Ethernet network On Physical link between SDA-4H and crossover Ethernet port connection Blinking Traffic flow between SDA-4H and crossover Ethernet port network Off No link between SDA-4H and crossover Ethernet port connection On Power received by the SDA-4H. Off No power received by SDA-4H Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the SDA 9.7.2. SDA-4S Models Table 9-5 describes the SDA-4S model’s LED indicators. Table 9-5: Description of the SDA-4S model’s LED indicators LED 2, 3, 4, and 5 Color Orange Green Orange POWER 02030311-05 Green Status Meaning On Physical link (10BaseT) between SDA-4S and SPR Blinking Traffic flow between SDA-4S and SPR Off No link between SDA-4S and SPR On 100BaseT physical link between SDA-4H and Ethernet network Blinking 100BaseT traffic flow between SDA-4H and Ethernet network Off No traffic flow between SDA-4S and Ethernet network On 10BaseT physical link between SDA-4H and Ethernet network Blinking 10BaseT traffic flow between SDA-4H and Ethernet network Off No traffic flow between SDA-4S and Ethernet network On Power received by the SDA-4S model. Off No power received by SDA-4S model. Airspan Networks Ltd. 9-25 10 Installing the IDR This chapter describes the installation of the WipLL Indoor Data Radio (IDR), which is installed at the base station. This chapter includes the following sections: ! Overview ! Physical Dimensions and Basic Design ! Mounting the IDR Desk Mounting Wall and Pole Mounting ! Connecting a Third-Party External Antenna ! Connecting to an Ethernet Network ! Positioning IDR for Optimum RF Reception ! Connecting to PC for Serial Configuration ! Connecting Power Power LEDs 02030311-05 Airspan Networks Ltd. 10-1 Installing the IDR Hardware Installation Guide 10.1. Overview The IDR device is an optional WipLL device that combines the functionality of the SPR and SDA devices. The IDR has a built-in antenna that provides an interface for transmission with the base station. In addition, the IDR provides an interface for 10Base-T Ethernet with the subscriber's network. However, unlike the SDA, a separate power supply unit (power adapter) powers the IDR. The IDR is available in two models: ! IDR with an internal antenna ! IDR with a TNC connector for connecting to a third-party external antenna RF link to BSR Optional external antenna RF cable IDR PC Figure 10-1: Typical IDR setup at subscriber's premises (showing optional antenna) 10-2 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR Warning: To avoid electrical or fire hazard, ensure that all connections to the IDR are performed prior to connecting the power supply. Note: The digital portion of the transceiver has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try correct the interference by performing one or more of the following measures: - Reorientate or relocate the receiving antenna - Increase separation between the equipment and receiver - Connect the equipment to an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help 02030311-05 Airspan Networks Ltd. 10-3 Installing the IDR Hardware Installation Guide 10.2. Physical Dimensions and Basic Design The IDR is encased in a chassis providing access to the IDR's communication port at the front panel. TNC-type connector for 3rd party external antenna Chassis cover bolt LEDs RJ-11 serial port RJ-45 10Base-T port Molex 6-pin power port Figure 10-2: IDR front panel with cover removed exposing ports The IDR's physical dimensions are described in Table 10-1. Table 10-1: IDR physical dimensions Parameter Weight Value 1,43 kg Dimensions (H x W x D) • IDR with built-in antenna • 155 mm (6.1 inches) x 233 mm (9.17 inches) x 74.5 mm (2.93 inches) • IDR with an external antenna • 120.5 mm (4.74 inches) x 61mm (2.4 inches) x 35 mm (1.37 inches) 10-4 Comment Airspan Networks Ltd. Note: Dimensions exclude the external power adapter. 02030311-05 Hardw are Installation Guide Installing the IDR 10.3. Mounting the IDR The IDR may be mounted in the following ways: ! Desk ! Pole ! Wall Note: Before mounting or attaching any brackets to the IDR, ensure that all cables are securely attached and that the unit functions correctly in the proposed location. 10.3.1. Desk Mounting The IDR may be mounted on a desk in one of the following ways: ! Vertically ! Horizontally 02030311-05 Airspan Networks Ltd. 10-5 Installing the IDR Hardware Installation Guide 10.3.1.1. Vertical-Desk Mounting A base plate is provided to mount the unit vertically on the desk, i.e., in standing position. The base plate is designed to fit in one position only. To desk mount the IDR in a vertical position: ! Insert the IDR into the base and press firmly until the tabs click into place. See Figure 10-3. Deskmounting plate Figure 10-3: IDR vertical desk mounting 10-6 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR 10.3.1.2. Horizontal-Desk Mounting To position the IDR horizontally on the desk, four rubber pads, supplied with the unit, must be fitted to avoid damage to mounting surfaces. mTo desk mount the IDR in a horizontal position: ! Secure the rubber pads to the posts provided on the rear of the IDR using four self-tapping screws. See Figure 10-4. Rubber foot Screw Figure 10-4: IDR horizontal desk mounting using supplied rubber pads and tapping screws 02030311-05 Airspan Networks Ltd. 10-7 Installing the IDR Hardware Installation Guide 10.3.2. Wall and Pole Mounting The IDR may be mounted to a wall or to a 5-cm diameter pole. Wall and pole mounting both use the same mounting brackets and wall hanger plate. 10.3.2.1. Assembling the Bracket and Hanger Plate The wall hanger plate secures the IDR to a wall or pole. The wall bracket and hanger plate allows positioning the IDR in the correct orientation. Holes are provided in the wall hanger plate for both pole and wall mounting options To assemble the bracket and hanger plate: 1. Insert a 4 mm hex nut into the slot on the tilt arm component 2. Holding the nut in place, attach the tilt arm to the mounting bracket using a 4 mm socket head bolt. Hand tighten the bolt only. See Figure 10-5. 3. Affix the complete mounting assembly to the rear of the IDR using the 4-off self-tapping screws supplied with the kit. Mounting Bracket Screw Tilt Arm Nut Figure 10-5: Mounting bracket assembly 10-8 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR 4. Attach the wall bracket assembly to wall hanger using an M4 socket-head bolt and nut as shown in Figure 10-6. The bolt is only to be hand tightened at this stage. Wall Hanger M-4 nut Screw Mounting bracket assembly Figure 10-6: Wall hanger fixing method Figure 10-7: Wall hanger & mounting bracket assembly 02030311-05 Airspan Networks Ltd. 10-9 Installing the IDR Hardware Installation Guide 5. Once assembled, the IDR mounting bracket assembly may be secured to the rear of the IDR using the 4-off self-tapping screws supplied in the unit fixing kit. See Figure 10-8. Self tapping Screws Figure 10-8: Mounting bracket assembly secured to IDR 10-10 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR 10.3.2.2. Pole Mounting Prior to mounting the IDR to a pole the wall mounting bracket assembly must be fitted as described in the previous section. To pole mount the IDR: 1. Offer up the IDR assembly to the pole as shown in Figure 10-9. 2. Insert 2-off M10 bolts through the holes in the wall hanger. 3. Slide the clamp-holder into position and secure using washers, spring-washers and nuts as illustrated in Figure 10-10. Finger-tighten the fasteners. 4. Slide the IDR to the required location on the pole and fully tighten the fasteners. Clamp holder Washer Spring Washer Bolt Hex Nut Figure 10-9: IDR pole mounting components 02030311-05 Airspan Networks Ltd. 10-11 Installing the IDR Hardware Installation Guide Figure 10-10: IDR secured to a pole To set the correct IDR inclination: 1. Loosen the 2-off M4 socket head screws on the mounting bracket tilt-arm 2. Position the IDR at the desired angle. 3. Re-tighten the 2 off socket screws on the tilt arm. 10-12 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR 10.3.2.3. Wall Mounting Warning: Prior to drilling holes in a wall ensure that there are no hidden services such as electricity cables or water pipes. A stop must be used on the power drill to ensure that bored holes do not exceed 35 mm. To mount the IDR on a wall: 1. Loosen the 2-off M4 socket head screws on the mounting bracket tilt-arm and remove the wall hanger. 2. Offer up the wall hanger to the wall and scribe through the mounting hole locations. 3. Drill holes to suit the type of wall fixing. 4. If required insert anchor plugs suited to the wall material. 5. Affix the wall hanger using 4-off screws suited to the anchor plugs and wall material. 6. Re-attach the IDR mounting bracket to the wall hanger. Finger tighten the screws. 7. Position the IDR at the desired inclination. 8. Re-tighten the screws to lock the IDR in position. 02030311-05 Airspan Networks Ltd. 10-13 Installing the IDR Hardware Installation Guide 10.4. Connecting a Third-Party External Antenna The IDR provides a TNC-type connector for connecting a third-party antenna to the IDR. This antenna can be placed on the subscriber’s windowsill to provide better RF signal reception with the BSR. Note: Airspan supplies unterminated cables for N-type connectors. Therefore, refer to the cable crimping procedures for N-type connectors detailed in Appendix B, “Cable Crimping". ! Connector: TNC-type male Warning: Before connecting the external antenna, ensure that the IDR is NOT connected to the power source. 10-14 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR Figure 10-11: Connecting a third-party antenna Warning: It is the responsibility of the person installing the WipLL system to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), that only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance with FCC rules CFR47 part 15.204. The installer should configure the output power level of antennas according to country regulations and per antenna type. 02030311-05 Airspan Networks Ltd. 10-15 Installing the IDR Hardware Installation Guide 10.5. Connecting to an Ethernet Network The IDR provides one Ethernet interface for the subscriber’s Ethernet network. This port is located on the front panel, and labeled Ethernet. ! Connector: 8-Pin RJ-45 ! Cable: CAT-5 ! Connector pinouts: Pin Function Rx+ RxTx+ Not Connected Not Connected TxNot connected Not connected To connect IDR to the subscriber’s Ethernet network: 1. Attach the 8-pin RJ-45 connector, at one end of the cable, to the IDR's Ethernet port, labeled Ethernet (see Figure 10-12). 2. Attach the 8-pin RJ-45 connector, at the other end of the cable, to the PC's LAN port (see Figure 10-12). 10-16 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR Figure 10-12: Connecting IDR to a client PC 02030311-05 Airspan Networks Ltd. 10-17 Installing the IDR Hardware Installation Guide 10.5.1. Ethernet LED Indicator The IDR provides one LED that indicates an Ethernet connection. This LED is labeled Ethernet and is located on the IDR’s top panel. Table 10-2: Description of Ethernet LEDs LED Ethernet Color Orange Status Indicates On Physical link between IDR and Ethernet network Off No physical link between IDR and Ethernet network Blinking Data is flowing through the Ethernet port 10.6. Positioning IDR for Optimum RF Reception Once mounted to a wall, pole, or desk the IDR unit may be positioned to ensure the best RF signal communication with the BSR. The RF signal strength is indicated by three LEDs on the IDR chassis. The following table describes the RF signaling strength indicator LEDs. Table 10-3: Description of RF signal strength LEDs LED Color Function Status Description Previous Releases RSSI LEDs: LO, MED, and HI 10-18 Green RSSI level Release 4.2B All LEDs On RSSI ≥ -60 dBm RSSI ≥ -60 dBm Two LEDs On -65 dBm ≤ RSSI ≤ -61 dBm -70 dBm ≤ RSSI < -60 dBm One LED On -70 dBm ≤ RSSI ≤ -66 dBm -80 dBm ≤ RSSI < -70 dBm One LED Blinking RSSI ≤ -77 dBm -90 dBm ≤ RSSI < -80 dBm All LEDs Off -76 dBm ≤ RSSI ≤ -71 dBm RSSI < -90 dBm Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR Figure 10-13: IDR LED indicators To position the IDR for optimum RF signal: ! Position the IDR until all three RF signaling strength indicator LEDs are lit. Refer to Section 10.3.2, “Wall and Pole Mounting” page 10-8 for details on adjusting IDR wall and pole mounting position. For desk-top mounting, the IDR can be simply relocated to obtain the strongest signal. 02030311-05 Airspan Networks Ltd. 10-19 Installing the IDR Hardware Installation Guide 10.7. Connecting to PC for Serial Configuration To perform IDR initial configuration, you need to connect the IDR’s RJ-11 port to the serial port of a PC running the WipLL network management application (i.e., WipConfig). The IDR’s RJ-11 port labeled Serial, located on the front panel, connects to the serial port of a PC via a cable with an RJ-11 connector on the one end, and a 9-Pin D-type connector on the other (i.e., a direct serial cable connection-DCC). ! Connectors: 6-Pin RJ-11 male to 9-pin D-type female adapter 9-Pin D-type male to 9-Pin D-type female adapter ! Cable: Straight-through cable with 6-Pin RJ-11 male on one end and 9-Pin D-type female on the other (connects between IDR and crossover cable) Crossover cable with 9-Pin D-type male on one end and 9-Pin D-type female on the other (connects straight-through cable to PC) 10-20 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR ! Connector pinouts: Crossover cable Straight-through cable 6-Pin RJ-11 Pin Function Rx Not connected NC NC GND Tx 9-Pin D-type female 9-Pin D-type male 9-Pin D-type male Pin Pin Pin To connect the IDR to the WipLL management station (PC): 1. Connect the 6-Pin RJ-11 connector to the IDR’s RJ-11 port (labeled Serial) located on the IDR’s front panel (see Figure 10-14). 2. Connect the 9-Pin D-type female connector, at the other end of the straightthrough cable, to the 9-Pin D-type male connector of the cross-over cable (see Figure 10-14). 3. Connect the 9-Pin D-type male connector, at the other end of the cross-over cable, to the PC’s serial port (see Figure 10-14). 02030311-05 Airspan Networks Ltd. 10-21 Installing the IDR Hardware Installation Guide Figure 10-14: IDR-to-PC Serial Cable Connections 10-22 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR 10.8. Connecting Power The IDR is powered by an external power supply (Triple Output External Adapter). The IDR connects to the power adapter via the IDR's power port located on the IDR’s front panel. The following table lists the external power supply specifications: Table 10-4: IDR power supply requirements Power parameter Units Voltages 110-240 VAC Frequency 50 to 60Hz Maximum power consumption Less than 15W Warning: If you are using an external antenna, ensure that you connect the antenna before connecting the BSR to the power source. Warning: Ensure that plugs fitted to mains power leads for subscriber premises equipment are compatible with AC mains sockets. Do not replace plugs on power leads to suit local requirements without first verifying earthing practice for the country and equipment in question. Careful consideration must be given to issues including local wiring requirements, cable color-coding, and safety earthing and circuit protection requirements. Warning: To avoid electrical or fire hazard, ensure that the data connections to the IDR are made prior to connecting the power supply.The AC mains must be capable of supplying at least 230 VAC Prior to connecting to the power outlet, the following pre-connection inspection should be performed on power sockets: ! Power socket shall be visually inspected to ensure that no other equipment is connected to the power outlet. 02030311-05 Airspan Networks Ltd. 10-23 Installing the IDR Hardware Installation Guide ! There is no physical sign of damage to the power outlet. ! There should not be any visible sign of water or dampness on or around the power outlet. ! The plug and socket assemblies are to be firmly secured. ! The power outlet shall be checked using a proprietary plug tester such as a ‘Martindale Ze’ type. Checks are required to verify the earth loop impedance value and the presence of phase, neutral and earth connections. ! Connector: 6-Pin power connector ! Cable: 3-core 0.7mm² type ! Connector pinouts: Pin Function +6.5V +5V 3.3V GND Not connected Not connected To connect the power: 1. Plug the AC power adapter’s 6-pin Molex connector into the IDR’s power port labeled Power (see Figure 10-15). 2. Plug the AC power plug female, at the one end of the AC power cable, into the AC power adapter’s socket (see Figure 10-15). 3. Plug the AC power plug male, at the other end of the AC power cable, into the electrical outlet (see Figure 10-15). 10-24 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Installing the IDR Figure 10-15: Connecting power to the IDR 02030311-05 Airspan Networks Ltd. 10-25 Installing the IDR Hardware Installation Guide 10.8.1. Power LEDs The IDA provides a power LED indicator, labeled Power, which indicates whether a power supply exists. The Power LED is located on the front panel of the IDR chassis. Table 10-5: Description of Power LEDs LED Power 10-26 Color Red Status Meaning On The SDA receives power supply Off No power received Airspan Networks Ltd. 02030311-05 A Glossary AC Alternating Current BNC Bayonet Neill Concelman (Connector type) BSDU Base Station Distribution Unit BSPS Base Station Power System BSR Base Station Radio CEP Common Earth Point DC Direct Current DCC Direct Serial Cable Connection GPS Global Positioning Satellite HSP Hop Synchronisation Process HSPP Hop Synchronisation Process Pulse IDR Indoor Data Radio IP Internet Protocol LED Light Emitting Diode mA Milliamperes MCB Miniature Circuit Breaker Mbps Mega Bits Per Second Nm Newton-metres NMS Network Management System NOC Network Operations Centre PSTN Public Switched Telephone Network RJ Registered Jack (modular connector) 02030311-05 Airspan Networks Ltd. A-1 Glossary Hardware Installation Guide SDA Subscriber Data Adaptor SME Small and Medium Enterprises SOHO Small Office/Home Office SPR Subscriber Premises Radio UPS Un-interrupted Power Supply UPVC Unplasticized Poly-Vinyl Chloride WAN Wide Area Network WipLL Wireless internet protocol -Local Loop A-2 Airspan Networks Ltd. 02030311-05 B Cable Crimping This chapter describes the procedure for crimping cables for 15-Pin D-type and Ntype connectors that are used in BSR/SPR-to-BSDU/SDA and BSR-to-GPS connections, respectively. The opposite ends of these cables are un-terminated, thereby providing length flexibility for connecting these WipLL units. Crimping procedures are described for the following cable-connector terminations: ! CAT-5e/15-Pin connections D-type cable/connector terminations for SPR-to-SDA ! Multipair Overall Shielded (22 AWG)/N-type cable/connector terminations for GPS antenna connections. ! GPS antenna connector Warning: Correct crimping of network cables is crucial for ensuring service integrity. 02030311-05 Airspan Networks Ltd. B-1 Cable Crimping Hardware Installation Guide B.1. Crimping CAT-5e Cable for 15-Pin D-Type Connectors This section describes the cable stripping and crimping of CAT-5e cables for 15-Pin D-type connectors used for BSR/SPR-to-BSDU/SDA connections. Airspan recommends the "ITT Canon DB15" (code number ‘DAW15P’) subminiature type. This connector is an Insulation Displacement Connector (IDC) which crimps and secures the cable at the connection point. Airspan recommends the following tools for stripping and crimping for 15-Pin Dtype connectors: ! Crimping tool—hand-crimper code DW115394-1. The crimper is a cyclic crimper and will not release the cable until a full termination cycle has been completed. The tool automatically indexes to the next pin on completion of the terminating cycle.(See Figure B-1.) Anti Backup locator Connector Guide Feed Slide Push in this direction to release ratchet mechanism Figure B-1: Hand-Crimping Tool for 15-Pin D-Type Connector B-2 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Cable Crimping The major features of the crimper are described in the following table: Table B-1: Main features of crimping tool Tool feature Terminating Head Wire Inserter Function Guides and supports the connector. • Cuts wire to be terminated. • Forces conductors into 2 slotted beams of the contact. Anti-backup locator Prevents connector from moving out of position for accurate termination. Feed Slide Automatically advances the connector after each termination. Adjuster Provides wire insertion depth adjustment Cam handle Activates the termination mechanism inside the head. Ratchet Pawl Releases the cam handle before it is fully closed should a problem occur during termination operation. ! Stripping tool—three-way stripping tool—1PAC10349AKM (see Figure B-2) Adjustment Screw Blade Adjustment Figure B-2: Stripping Tool 1PAC10349 AKM Cable crimping is performed in two stages: 1. Stripping the cable 2. Crimping the cable 02030311-05 Airspan Networks Ltd. B-3 Cable Crimping Hardware Installation Guide B.1.1. Stripping the Cable Before crimping the cables, you need to strip 50 mm of the cable. Before using the tool, ensure that the tool is correctly adjusted. Correct adjustment is obtained when the blade cuts the outer insulation without damage to the insulation of inner conductors. To strip the cable: 1. Cut the cable to length using cable shears (Airspan code 1PAC10333AKJ). 2. Strip 50 mm of the sheathing using stripping tool. 3. Insert the cable in the jaws of the cutting tool by squeezing the handles together. 4. Rotate 10 times, release the tool, and remove the cable and insulation. B-4 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Cable Crimping 5. Use a steel rule (1PAC10042AAV) to verify the stripped dimension. 6. Inspect the cut for evidence of damage, i.e. has the braid been cut? If so cut off cable and reset tool. B.1.2. Crimping the Cable Once you have stripped 50 mm of the cable, you can begin crimping the cable to the 15-Pin D-type connector. Note: For 15-Pin D-type connector pinouts, see the relevant chapter on the specific WipLL equipment. To crimp the cable: 1. Insert the 15-Pin D-type connector into the left slot of the crimper until the desired connector pin position aligns with the slot. 2. Insert the wire into the left side of the crimper slot until the end enters the hole. 3. Adjust the desired length of the wire. 4. Centre the wire in the slot. 5. Squeeze the crimper handles until the wire inserter bottoms out. 6. Release the crimper handles—the inserter retracts and the connector advances to the next pin position. 7. Repeat the above until all pin contacts of the row have been terminated. 02030311-05 Airspan Networks Ltd. B-5 Cable Crimping Hardware Installation Guide Wire Slot Connector advances in this direction Figure B-3: Crimping tool 8. When finished, remove the connector from the right side of connector slot. Note: The connector must be inserted into the crimper from the left hand side only. Should the connector jam in the terminating position, excessive force must not be used: the spigot between the tool handles should be used to release the ratchet mechanism. The crimper handle will not allow release until a full termination cycle of the connector has been completed. B.1.3. Inspecting the Crimped Connector Each crimped connector is to be tested that it has been correctly crimped: ! Ensure that the wire extends beyond the front pin contact slot by a minimum of 0.5 mm ! Ensure that the two legs of the insulation crimp barrel are closed to secure the insulation of the wire B-6 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Cable Crimping Note: The purpose of the barrel is to prevent the wire from being lifted from the contact. It is not necessary to have the barrel wrapped tightly around the insulation. ! Ensure that the contact cavity has not been deformed ! Confirm integrity by holding the connector in one hand and pulling lightly on the cable. Figure B-4 shows points to be observed during quality inspection. Correct Termination 0.5mm Min Acceptable Termination Wire was not fully inserted before termination ( or was slightly drawn back during termination) Incorrect setting of tool Figure B-4: Crimp Connector Inspection 02030311-05 Airspan Networks Ltd. B-7 Cable Crimping Hardware Installation Guide B.1.4. Housing the Connector For outdoor cable installations, the connector is to be protected in a waterproof housing assembly as shown in Figure B-5. Note: The housing, cable seal, and clamping nut are to be slid onto the cable prior to crimping the connector in place. To assemble the connector in a waterproof housing: 1. Insert the connector into the waterproof housing ensuring that a "click" is heard. 2. Screw the cable seal into place ensuring that the cable outer sheath is inside the connector body. 3. Secure the cable in place with the lock nut. Sealing Ring Connector Housing Securing Screws Cable Seal Clamping Nut Figure B-5: Waterproof Connector housing assembly For indoor cabling applications it is not necessary to use a waterproof housing for the connector. B-8 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Cable Crimping To assemble the un-housed connector: 1. Insert the connector terminal block into the connector body. 2. Secure the cable onto the connector body using the cable clamp. Ensure that the cable outer sheath is within the connector body. 3. Snap the top section of the connector body into place. 4. Ensure that the connector is secure within the housing by applying a light pull on the cable. 02030311-05 Airspan Networks Ltd. B-9 Cable Crimping Hardware Installation Guide B.2. Crimping N-type Connectors This section describes the cable stripping and crimping Multipair Overall Shielded (22 AWG) cables for N-type connectors used for BSR/SPR connections to external antennas. Airspan recommends using the following tools for crimping of N-type connectors: ! Crimp tool: Erma 29020 with die set 29207. ! Stripping tool: Maxi Corex, fitted with the 9.0 to 11.5mm cable clamp (blue) and the 9.5 to 3.2 blade cassette (green). B.2.1. Stripping the Cable To strip the cable: 1. The first cut should be set to cut through the outer sheath, braid and dielectric. Scoring of the centre conductor should not occur. 2. The second cut should be set to cut through the outer sheath and the braid. Important attention must be paid to the dielectric where it meets the braid. It is preferable that no cutting of the dielectric takes place, however, because of the construction of cables and tolerance build up there may be occasion where a slight cutting of the dielectric is unavoidable. This must be kept to an absolute minimum. This has been termed the compromise cut and is acceptable practice. 3. The final cut should be set to cut through the outer sheath only. Scoring of the braid should not occur. 4. All sections of the stripped Ethernet cable should be easily removed if the blade settings are correct. To adjust the blade settings use the allen key provided and apply it to the grub screws at the back of the stripping tool. Clockwise will increase blade depth, anti-clockwise will reduce blade depth. 5. Set stripping tool slide mechanism to 5. 6. Place the cable into the stripping tool with approximately 12 mm protruding from the end of the tool. B-10 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Cable Crimping 7. Clamp the tool around the cable and lock in position. 8. Holding the cable in the left hand and stripping tool in the right hand (index finger through finger hole) rotate tool in a clockwise direction for 10 turns. 9. Move slide mechanism to number 3. 10. Rotate tool in a clockwise direction for 10 turns. 11. Move slide mechanism to number 1. 12. Rotate tool in a clockwise direction for 10 turns. 13. Unlock the tool to remove cable then lock shut. Always keep the stripping tool locked shut when not in use. Take care when handling the blade insert. 14. Twist off stripped cable sections. 02030311-05 Airspan Networks Ltd. B-11 Cable Crimping Hardware Installation Guide B.2.2. Assembling the Connector Once you have stripped the cable, you can house the cable: To house the cable: 1. Fit an insulating boot if required, over the cable, cutting enough of the pointed end to enable the cable to go through the resulting hole with a fairly tight grip. Push ferrule over the stripped section of cable. 2. Rotate the centre conductor in relation to the cable to splay the braid and any foil from the dielectric, which will allow the later correct fitting of the connector body (over the dielectric). See Figure B-6.Take care not to damage the braid. Figure B-6: Rotating conductor B-12 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Cable Crimping 3. Trim the centre conductor back to 5.5 mm from the end of the dielectric. Use the cable shears provided and not the side cutters. 4. Fit centre pin on to the centre conductor. The centre conductor should be seen through the inspection hole (see Figure B-7). Ensure that the shoulder of the pin is butted up to the cable’s dielectric. Figure B-7: Fitting center pin onto center conductor B.2.3. Crimping To crimp the GPS connector: 1. Using an Erma tool and 29207 die, small aperture, crimp centre pin to centre conductor. The crimp section should be just be below the inspection hole (see Figure B-7). Do not crimp the shouldered section as it will cause flashing. 2. Fit the connector body over the centre pin and between the braid and dielectric (see Figure B-6). Do not trap any of the braid between the dielectric and back face of the connector body. If the connector is supplied with a nylon washer, fit this to the rear of the connector before application to the cable. 3. Push the connector body firmly home. The centre pin should align with the end of the internal diameter of the connector body. 4. Push the ferrule up to the end of the cable, covering the braid. There should be no braid showing between the end of the ferrule and the connector body. Rotating the ferrule may rectify this, if not trim the braid slightly to suit. 02030311-05 Airspan Networks Ltd. B-13 Cable Crimping Hardware Installation Guide 5. Crimp the ferrule using the large aperture of the 29207 die. When offering up the tool the die should be positioned so as it aligns with the braid and not the outer sheath of the cable. 6. Connectors with nylon washers, the crimp is to be made with the dies held firmly against the washers face. B-14 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Cable Crimping B.3. Crimping GPS Cable Connectors Airspan recommends the following tools for crimping for N-type connectors: ! Crimping tool—Daniels AFM8 (M22520/2-01). Figure B-8: Crimping tool – Daniels AFM8 Once you have housed the stripped cable, you can now crimp the cable to an N-type connector. Note: The crimper cannot be opened without completing the cycle. To crimp the cable: 1. Ensure that the crimper is in the open position. 2. Remove safety clip from positioner guide. 3. Select the Positioner for contact to be crimped. 4. Insert the Positioner into the positioner guide and turn it 90 degrees until bayonet pins lock. 5. Raise and rotate the Selector knob until the number indicated on data plate for cable size to be crimped is in line with Sel. No. arrow. 02030311-05 Airspan Networks Ltd. B-15 Cable Crimping Hardware Installation Guide 6. Insert the contact and prepared cable into the indenter opening from the side opposite the Positioner. 7. Squeeze crimper handles together until the ratchet releases. The handle will return to the open position. 8. Remove crimped contact and cable. B-16 Airspan Networks Ltd. 02030311-05 C Technical Specifications This appendix lists the technical specifications for the following WipLL units: ! WipLL Base Station equipment: Base Station Radio (BSR) Point-to-Point Radio (PPR) Base Station Distribution Unit (BSDU) Base Station Power Supply (BSPS) GPS antenna ! WipLL Customer premises equipment: Subscriber Premises Radio (SPR) Subscriber Data Adapter (SDA) − SDA-1 − SDA-4H − SDA-4S models Indoor Data Radio (IDR) 02030311-05 Airspan Networks Ltd. C-1 Technical Specifications Hardware Installation Guide C.1. Base Station WipLL Equipment The following sub-sections list the specifications of the following WipLL Base Station equipment: ! Base Station Radio (BSR) ! Point-to-Point Radio (PPR) ! Base Station Distribution Unit (BSDU) ! Base Station Power Supply (BSPS) C-2 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Technical Specifications C.1.1. Base Station Radio (BSR) Table C-1: BSR and MAC Specifications Parameter Operating frequency range Value Comment • 2.4 GHz • ISM band • 3.x GHz, MMDS, 2.8 GHz • Licensed band • 5.8 GHz • Unlicensed band • 900 MHz • Unlicensed band *Other ranges available for trial Spectrum spreading method Frequency hopping Duplex method • Time Division Duplex (TDD) - 2.4 GHz, 2.8 GHz, 3.x GHz, MMDS, 900 MHz, and 5.8 GHz Per ETSI EN301 253 • Frequency Division Duplex (FDD) - 3.x GHz Transmit bit rates Up to 4 Mbps BER and distance dependent Channel spacing 1 MHz For 3.5 GHz the channel spacing can be 1 MHz or 1.75 MHz Output power from the BSR Up to 27 dBm, configurable at 2.4 GHz Depending on local regulations, maximum output power can be configured at the factory Modulation method 8-level CPFSK Channel access method PPMA / Adaptive TDMA Protocol efficiency Up to 80% Number of SPR/IDR per BSR Up to 126 02030311-05 Airspan Networks Ltd. For large data packets C-3 Technical Specifications Hardware Installation Guide Table C-2: BSR EMC and Radio Standards Compliance Parameter Value Radio Standards Compliance • ETSI EN 300 328-1 • ETSI EN 301 253 • FCC part 15 • RSS139 • Telec • ETSI ETS 300 826 EMC • ETSI EN 300 385 • ETSI EN 300 386-2 • ETSI ETS 300 132-2 • FCC part 15 Table C-3: BSR Agency Certification Parameter Value Emissions / Immunity EN 300 339 EN 300 386-2 ETS 300 328 Safety EN / IEC 60950 Environmental ETS 300 019-2-x Table C-4: BSR Network Specifications Parameter Value Comment Filtering Rate 10,500 frames/sec At 64 byte packets Forwarding Rate 1,300 frames/sec At 64 byte packets Routing table length 200 networks, including subnets Table C-5: BSR Power Requirements Parameter Value Voltage 48 VDC nominal • Minimum: • 30 VDC • Maximum: • 55 VDC Maximum Amperes: 500 mA C-4 Airspan Networks Ltd. Comment Voltage is received from the BSDU 02030311-05 Hardw are Installation Guide Technical Specifications Table C-6: BSR Environmental Conditions Parameter Value Operating temperature of outdoor units (BSR and SPR) -30ºC to +60ºC Storage temperature -40ºC to +80ºC Comment Optional range of -40ºC to +70ºC Table C-7: BSR Network Interface Parameter Value Ethernet Network UTP EIA/TIA Standards Compliance ANSI/IEEE 802.3 and ISO/IEC 8802-3 10Base-T compliant Serial Port RS-232 Comment Category 5 Table C-8: BSR Physical Dimensions Parameter Value Height 400 mm Width 317 mm Depth 65.5 mm Weight 4.7 kg 02030311-05 Airspan Networks Ltd. Comment Excluding mounting kit C-5 Technical Specifications Hardware Installation Guide C.1.2. Point-to-Point Radio (PPR) Table C-9: PPR Radio Specifications Parameter Operating frequency bands Value • 2,400 to 2,500 MHz • 3,400 to 3,800 MHz • 5,725 to 5,875 MHz Duplex method • Time Division Duplex (TDD) for all bands • Frequency Division Duplex (FDD) for 3.4 to 3.8 GHz Radio Technology FH-CDMA Multiple Access Method PPMA Output power 27 dBm Antenna type (built-in) • PPR • 18 dBi / 15 dBi • SPR • 18 dBi / 15 dBi Sub-Channel Spacing 1 MHz Modulation Multilevel (2, 4, or 8) CPFSK Receiver Sensitivity (BER 1E6 at 2/4/8 FSK) -90/ -83/ -75 dBm Throughput Up to 4 Mbps per PPR-SPR link Radio Standards Compliance • ETSI EN 300 328-1 • ETSI EN 301 253 • FCC part 15 • RSS139 • Telec EMC • ETSI ETS 300 826 • ETSI EN 300 385 • ETSI EN 300 386-2 • ETSI ETS 300 132-2 • FCC part 15 C-6 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Technical Specifications C.1.3. Base Station Distribution Unit (BSDU) Table C-10: BSDU Network Specifications Parameter Value Filtering Rate 105,000 Frames / sec Forwarding Rate 62,500 Frames / sec Table C-11: BSDU Power Requirements Parameter Value Voltage 48VDC nominal Power consumption Maximum 300W (including the feeding of 6 × BSRs) Table C-12: BSDU Environmental Conditions Parameter Value Operating Temperature 0ºC to +50ºC Storage Temperature -40ºC to +80ºC Table C-13: BSDU Network Interface Parameter Value Comment Ethernet Network 100/10Base-T: UTP EIA/TIA Category 5 Standards Compliance ANSI/IEEE 802.3, ISO/IEC 8802-3 10/100 Base-T compliant Serial Port RS-232 Table C-14: BSDU Physical Dimensions Parameter Value Height 4.32 cm Width 48.26 cm Depth 22.86 cm Weight 2.9 kg 02030311-05 Airspan Networks Ltd. C-7 Technical Specifications Hardware Installation Guide C.1.4. Base Station Power Supply (BSPS) Table C-15: BSPS Rectifier Specifications Parameter Input Output General Value Voltage 90VAC to 270VAC Current (nominal) 3.2A @ 230V / 4.3A @ 115V Frequency 47Hz to 63Hz Power factor (nominal line/load) Greater or equal to 0.993 Voltage (default) 53.5VDC Regulation (line & load) ±0.4% Adjustable range 47 to 58 VDC Current 12A @ 54V Ripple & noise 50mVp-p Efficiency (nominal load) 85% @ 230V / 82% @ 115V Overload current <12A Over-voltage protection 60 VDC Over-temperature protection (measured on case, upper panel corner) • 80±5°C rectifier stops Walk-in time < 0.5 sec Hold-up time 40 ms Withstand voltage (1 min) • 4230VDC INPUT/OUTPUT • 72±5°C rectifier recovers • 2120VDC INPUT/GND • 1700VDC OUTPUT/GND C-8 Working temperature -10 to 45°C Storage temperature -50 to 80°C Dimensions (mm) 235 x 150 x 50 (L x W x H) Weight 1100g EMC Refer to system specifications Safety According to: IEC950 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Technical Specifications Table C-16: BSPS DC Distribution Specifications Parameter Input Output General 02030311-05 Value Voltage 90VAC to 270VAC Current (at full load) N =Number of rectifier modules • N*3.2A @ 230V Frequency 47 Hz to 63 Hz Power factor (at full load) Greater or equal to 0.993 Voltage (programmable) 42 to 60VDC ± 0.5VDC Default float and boost voltage 54 and 57VDC respectively Regulation (line, load, sharing) ±1% Current N*12A (48A max.) Psophometric noise -52 dBm (over 600 &) Ripple & noise 50mVp-p Efficiency (nominal load) 85% @ 230V / 82% @ 115V Overload current < N*12A Over-voltage protection 60VDC Walk-in time < 1 sec Hold-up time 40 ms Output current indication 10 LED’s bar-graph Active current sharing ±10% accuracy at full load Withstand voltage (1 min) 2120VDC INPUT/GND Working temperature -10 ¸ 45°C Storage temperature -50 ¸ 80°C Dimensions (19” X 3U) Depth is 320mm W/O terminals, 360mm with terminals Weight 13 kg (main unit + 3 rectifiers) RS232 Communication 9600 bps, no-parity, 1 stop-bit • N*4.3A @ 115V Airspan Networks Ltd. C-9 Technical Specifications Hardware Installation Guide Parameter EMC Value According to: • EN300-386-2 SUB 7.2.3 • EN55022 class B • IEC1000-4-2 • IEC1000-4-3 • IEC1000-4-4 • IEC1000-4-5 • IEC1000-4-6 • IEC1000-4-11 • IEC1000-3-2 • IEC1000-3-3 LVLD (optional) C-10 Safety According to: IEC950 Maximum current withstand 2x70A Trip voltage level Disconnect default: 43± 0.5 VDC, user programmable Re-connect: with AC recovery Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Technical Specifications C.1.5. GPS antenna Table C-17: SPR Power Requirements Parameter Value Voltage Input 36 VDC Consumption 1.8W Comment Supplied by WipLL’s BSDU Table C-18: Environmental Considerations Parameter Operating temperature Value Comment -30ºC to +75ºC Table C-19: GPS General Parameter Value Input DGPS (Differential GPS) Output 1 pulse per second Standards Compliance MIL-STD 810E Interface standard RS-422 Comment Table C-20: GPS Dimensions Parameter Value Diameter 115 mm Height 90 mm 02030311-05 Airspan Networks Ltd. Comment C-11 Technical Specifications Hardware Installation Guide C.2. Customer Premises WipLL Equipment The following sub-sections list the specifications of the following WipLL CPE equipment: ! Subscriber Premises Radio (SPR) ! Subscriber Data Adapter (SDA) ! Indoor Data Radio (IDR) C.2.1. Subscriber Premises Radio (SPR) Table C-21: SPR and MAC Specifications Parameter Value Comment • 2.4 GHz • ISM band • 3.x GHz, 2.8 GHz, MMDS • Licensed band • 5.8 GHz • Unlicensed band Spectrum spreading method Frequency hopping Per ETSI EN 301 253 Duplexing Method • Time Division Duplex (TDD) 2.4 GHz, 2.8 GHz, MMDS, 3.x GHz, and 5.8 GHz Operating frequency • Frequency Division Duplex (FDD) 3.x GHz Transmit Bit Rates Up to 4 Mbps Channel spacing 1 MHz Output power from the radio Up to 27 dBm, configurable at 2.4 GHz Modulation method 8 level CPFSK Channel access method PPMA / Adaptive TDMA Protocol efficiency Up to 80% C-12 Airspan Networks Ltd. BER and distance dependent Depending on local regulations. Maximum power output can be set at the factory. For large data packets 02030311-05 Hardw are Installation Guide Technical Specifications Table C-22: SPR EMC and Radio Standards Compliance Parameter Value Radio Standards Compliance • ETSI EN 300 328-1 • ETSI EN 301 253 • FCC part 15 • RSS139 • Telec • ETSI ETS 300 826 EMC • ETSI EN 300 385 • ETSI EN 300 386-2 • ETSI ETS 300 132-2 • FCC part 15 Table C-23: SPR Agency Certification Parameter Value Emissions / Immunity EN 300 339, EN 300 386-2, ETS 300 328 Safety EN/IEC 60950 Environmental ETS 300 019-2-x Comment Table C-24: SPR Network Specifications Parameter Value Comment Filtering rate 10,500 frames / sec At 64 bytes Forwarding rate 1,300 frames / sec At 64 bytes Routing table length 16 Table C-25: SPR Power Requirements Parameter Value • Voltage • 48 VDC nominal • Minimum • 30 VDC • Maximum • 55 VDC Consumption Maximum 02030311-05 Airspan Networks Ltd. Comment Power supplied from the SDA 500 mA C-13 Technical Specifications Hardware Installation Guide Table C-26: Environmental Considerations Parameter Value Operating temperature -30ºC to +60ºC Storage temperature -40ºC to +80ºC Table C-27: Network Interface Parameter Value Ethernet Network UTP EIA / TIA Standards Compliance ANSI/IEEE 802.3 and ISO/IEC 8802-3; 10BaseT compliant Serial Port RS-232 Comment Category 5 Table C-28: SPR Physical Dimensions (w/o High Gain Antenna) Parameter Value Height 311 mm (12.24 inches) Width 244 mm (9.6 inches) Depth 65.5 mm (2.57 inches) Weight 2.5 kg Comment Excluding mounting kit Table C-29: SPR Physical Dimensions (with High Gain Antenna) Parameter Value Height 400 mm (15.74 inches) Width 317 mm (12.48 inches) Depth 65.5 mm (2.57 inches) Weight 4.7 kg Comment Excluding mounting kit Note: The SPR cable and connector are the same as the BSR. C-14 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Technical Specifications C.2.2. Subscriber Data Adapter (SDA) C.2.2.1. SDA-1 Table C-30: SDA-1 Physical Dimensions Parameter Value Height 200 mm Width 150 mm Depth 40 mm Weight 47 kg Table C-31: SDA Power Requirements Parameter Value Output Voltage -48VDC nominal Power supply 110-240 VAC, 50/60Hz, 0.3-0.7A Table C-32: SDA-1 Environmental Considerations Parameter Operating temperature Value 0ºC to +50ºC Table C-33: SDA-1 Network Interfaces Parameter Value Data from SPR/BSR DB15 Ethernet RJ45 socket for a PC interface Power AC power connector 02030311-05 Airspan Networks Ltd. C-15 Technical Specifications Hardware Installation Guide C.2.2.2. SDA-4H Table C-34: SDA-4-H Physical Dimensions Parameter Value Height 200mm Width 150mm Depth 40mm Weight 53 kg Table C-35: SDA-4H Power Requirements Parameter Value Output Voltage -48VDC nominal Power supply 110-240 VAC, 50/60Hz, 0.3-0.7A Table C-36: SDA-4H Environmental Considerations Parameter Operating temperature Value 0ºC to +50ºC Table C-37: SDA-4H Network Interfaces Parameter Value Data from SPR/BSR DB15 Ethernet Three RJ45 socket for a PC interface; one RJ-45 for cross over connection Power AC power connector C-16 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Technical Specifications C.2.2.3. SDA-4S Models Table C-38: SDA-4S Physical Dimensions Parameter Value Height 200 mm (7.87 inches) Width 150 mm (5.9 inches) Depth 40 mm (1.57 inches) Weight 53 kg Table C-39: SDA-4S Power Requirements Parameter Value Output Voltage -48VDC nominal Power supply 110-240 VAC, 50/60 Hz, 0.3-0.7A Table C-40: SDA-4S Environmental Considerations Parameter Operating temperature Value 0ºC to +50ºC Table C-41: SDA-4S Network Interfaces Parameter Value Data from SPR/BSR 15-pin D-type Ethernet Four 8-pin RJ-45 10/100BaseT sockets for PC interface. These ports support 10/100 Mbps Autosensing (Autonegotiation), and MDI/MDI-X automatic crossover Power AC power connector 02030311-05 Airspan Networks Ltd. C-17 Technical Specifications Hardware Installation Guide C.2.3. Indoor Data Radio (IDR) Table C-42: IDR Radio and MAC Specifications Parameter Operating frequency Value Comment • 2.4 GHz • 3.45 GHz • 3.5 GHz • 900 MHz Spectrum spreading method Frequency hopping Duplex Method • Time Division Duplex (TDD) at 2.4 GHz and 900 MHz (Per ETSI ETS 300 328) ARIB-STD-T66 • Frequency Division Duplex (FDD) at 3.5 GHz and 3.45 GHz Transmit Bit Rates Up to 4 Mbps Channel spacing 1 MHz Output power from the radio Up to 27 dBm, configurable at 2.4 GHz Channel access method PPMA Protocol efficiency Up to 80% C-18 Airspan Networks Ltd. Depending on BER Depending on local regulations. Maximum power output can be set at the factory. At BER = 10-5, depending on the application 02030311-05 Hardw are Installation Guide Technical Specifications Table C-43: IDR EMC and Radio Standards Compliance Parameter Value Radio Standards Compliance • ETSI EN 300 328-1 • ETSI EN 301 253 • FCC part 15 • RSS139 • Telec • ETSI ETS 300 826 EMC • ETSI EN 300 385 • ETSI EN 300 386-2 • ETSI ETS 300 132-2 • FCC part 15 Table C-44: IDR Agency Certification Parameter Value • VCCI Class A Emissions / Immunity • ARIB-STD-T66 • ETSI 300 386-2 Safety EN/IEC 60950 Environmental ETS 300 019-2-x Table C-45: IDR Network Specifications Parameter Value Comment Filtering rate 10,500 frames/sec At 64 bytes Forwarding rate 1,300 frames/sec At 64 bytes Table C-46: IDR Power Requirements Parameter Value External Power Supply Voltage • Minimum: 100 VAC Operating Frequency Range 50 to 60 Hz Maximum Power consumption Less than 15W 02030311-05 • Maximum: 240VAC Airspan Networks Ltd. C-19 Technical Specifications Hardware Installation Guide Table C-47: IDR Environmental Considerations Parameter Value Operating temperature 0-50ºC Operating Humidity +30Cº 93% Storage temperature -40 – 70ºC Comment Maximum humidity Table C-48: IDR Network Interface Parameter Value Ethernet Network UTP EIA / TIA Standards Compliance ANSI/IEEE 802.3 and ISO/IEC 8802-3 10Base-T compliant Serial Port RJ-11 Comment Category 5 Table C-49: IDR Physical Dimensions Parameter Value Comment Weight 1,430 g Dimensions (H x W x D) • 155 mm (6.1 inches) x 233 mm (9.17 inches) x 74.5 mm (2.93 inches) • IDR with built-in antenna • 120.5 mm (4.74 inches) x 61mm (2.4 inches) x 35 mm (1.37 inches) • IDR with an external antenna Note: Dimensions exclude the external power adapter. Table C-8: IDR Pole Mounting Dimensions Parameter Value Minimum pole diameter 35 mm (1.37 inches) Maximum pole diameter 50 mm (1.97 inches) C-20 Airspan Networks Ltd. 02030311-05 D Summary of Connector Pinouts This appendix provides a summary of the connector pinouts for the WipLL devices. D.1. BSR/SPR-to-BSDU/SDA CAT 5 Connector Pinouts Table D-1 describes the 15-pin D-type connector pinouts for the CAT 5 cable that connects the BSR's/SPR's 15-pin D-type port to the BSDU's/SDA's 15-pin D-type port. Table D-1: 15-pin D-type to 15-pin D-type connector pinouts 15-pin D-type male 02030311-05 BSR/SPR Pin Wire color Function +48 VDC Blue / white -48 VDC Blue Tx+ Orange / white Tx- Orange Rx+ Green / white Rx- Green Sync.+ Brown / white Sync.- Brown Airspan Networks Ltd. Wire pair Pin +48 VDC -48 VDC Rx+ Rx- Tx+ Tx- Sync.+ Sync.- BSDU/SDA Function D-1 Summary of Connector Pinouts Hardware Installation Guide Notes: - Pins 9 through 15 of the 15-pin D-type connector are not used. - The wire color-coding described in the table is WipLL's standard for wire color-coding. However, if you implement your company's wire color-coding scheme, ensure that the wires are paired and twisted according to the pin functions listed in Table D-1 (e.g., Rx+ with Rx-). WipLL uses the following wire color-coding standards for CAT 5 cables with 15-pin D-type to 15-pin D-type connectors on either ends (8 wires used): Figure D-1: WipLL wire color-coding for 15-pin D-type connectors Note: The wires are twisted together in pairs, for example, blue/white with blue, and orange/white with orange. This prevents electrical interference between the transmitter pins. For example, pin 3 (Tx+; orange / white) is paired and twisted with pin 4 (Tx-; orange). D-2 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Summary of Connector Pinouts D.2. SPR Serial Connector Pinouts For BSR and SPR serial connections, a Y-cable is used. The Y-cable connects the BSR and SPR to the BSDU and SDA, respectively, as well as to the PC running the WipLL management application. Figure D-2 displays the Y-cable used to split the BSR/SPR 15-pin D-type port into two. PC 9-pin D-type female SPR 15-pin D-type male 15-pin D-type male Figure D-2: Y-cable for serial connection SDA Connector pinouts are described in the following tables: Table D-2: Y-cable SPR-to-SDA connector pinouts Straight-through Y-cable SPR 15-pin D-type male 02030311-05 Pin SDA Function Pin Function 0 VDC +48 VDC +48 VDC -48 VDC Ethernet Tx+ Rx+ Ethernet Tx- Rx- Ethernet Rx+ Tx+ Ethernet Rx- Tx- Hop Sync+ Sync.+ Hop Sync- Sync.- Airspan Networks Ltd. 15-pin D-type male D-3 Summary of Connector Pinouts Hardware Installation Guide Table D-3: Y-cable SPR-to-PC connector pinouts Straight-through Y-cable SPR 15-pin D-type male Pin PC Function Pin Function 12 GND GND 14 RS232 Rx Rx 15 RS232 Tx Tx 9-pin D-type female The Y-cable connector pin assignments are displayed shematically in Figure D-3. Figure D-3: Y-cable connector pin assignment D-4 Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Summary of Connector Pinouts D.3. BSR Serial Connector Pinouts The BSR provides a serial port for RS-232 serial interface to a PC. This serial communication connection allows you to perform BSR initial configuration. Table D-4: BSR-to-PC serial connector pinouts Crossover serial cable BSR 9-pin D-type male 02030311-05 Pin PC Function Pin Function Not connected (NC) NC RS232 Rx Tx RS232 Tx Rx NC NC GND GND NC NC NC NC NC NC NC NC Airspan Networks Ltd. 9-pin D-type female D-5 Summary of Connector Pinouts Hardware Installation Guide D.4. BSDU Connector Pinouts D.4.1. BSDU Daisy Chaining Table D-5: BSDU daisy chaining connector pinouts Crossover cable 8-pin RJ-45 Pin Description 8-pin RJ-45 Name Pin Tx+ Transmit Data+ Tx- Transmit Data- Rx+ Receive Data+ Rx- Receive Data- D.4.2. BSDU Synchronization ! Sync IN Table D-6: BSDU synchronization (Sync IN) connector pinouts Straight-through cable 8-pin RJ-45 male Pin D-6 Name Description TD+ Transmit data to GPS TD- Transmit data from GPS Rx+ Receive Data (hop synchronization) NC Not connected NC Not connected Rx- Receive Data (hop synchronization) 1PPS+ GPS pulse per second 1PPS- GPS pulse per second Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Summary of Connector Pinouts ! Sync OUT Table D-7: BSDU synchronization (Sync OUT) connector pinouts Straight-through cable 8-pin RJ-45 male Pin Name Description TD+ Transmit data to GPS TD- Transmit data from GPS Tx+ Transmit Data (hop synchronization) RD+ Receive Data (from GPS) RD- Receive Data (to GPS) Tx- Transmit Data (hop synchronization) 1PPS+ GPS pulse per second 1PPS- GPS pulse per second D.4.3. BSDU Serial Management The BSDU’s serial management 9-Pin D-type port (labeled Monitor) allows you to connect the WipLL’s network management system (WipConfig) to BSDU without assigning BSDU an IP address. Table D-8: BSDU serial management connector pinouts Straight-through 9-Pin D-type male Pin 02030311-05 Signal Rx Tx Airspan Networks Ltd. D-7 Summary of Connector Pinouts Hardware Installation Guide D.4.4. BSDU PC Network Management For BSDU network management, you can connect the BSDU’s two 10BaseT ports (i.e., loop the ports) to one another by a crossover cable, then connect the PC to one of the BSDU’s 100BaseT ports. If the two BSDU 10BaseT ports are not connected to one another, then you need to connect the PC to the BSDU’s right-most 10BaseT port (labeled 10Base-T 2). ! Looping two 10Base-T ports: Table D-9: BSDU 10Base-T connector pinouts for looping Crossover cable 8-pin RJ-45 male Pin Signal +Rx -Rx +Tx -Tx ! 100Base-T port connected to PC Table D-10: BSDU 100Base-T connector pinouts for management Straight-through cable 8-pin RJ-45 Pin D-8 Function +Tx -Tx +Rx -Rx Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Summary of Connector Pinouts D.4.5. BSDU 100Base-T Table D-11: BSDU 100Base-T LAN/WAN connector pinouts Straight-through cable 8-pin RJ-45 Pin Name Description Tx+ Transmit Data+ Tx- Transmit Data- Rx+ Receive Data+ Rx- Receive Data- D.5. GPS-to-BSDU Connector Pinouts The following table lists the connector pinouts for the cable connecting the GPS antenna to the BSDU. Table D-12: GPS-to-BSDU connector pinouts 12-pin female (GPS) Pin Pin name 15-pin D-type male (BSDU) Cable color Pin Lead POWER Red RX_DATA_1- Blue TD+ (after R5) RX_DATA_1+ Black TD- TX_DATA_1- Yellow RD- TX_DATA_1+ Black RD+ (after R3) RX_DATA_2- Brown RX_DATA_2+ Black GND Black 10 11 1PPS+ Green 1PPS- 12 1PPS- Black 1PPS+ (After R7) 02030311-05 Airspan Networks Ltd. D-9 Summary of Connector Pinouts Hardware Installation Guide D.6. Connector Pinouts for BSPS Serial Management via BSDU Table D-13: BSPS serial management connector pinouts BSDU 9-pin D-type female BSPS Pin Function Pin Function Rx Tx Tx Rx GND GND 8-pin RJ-45 D.7. IDR Connector Pinouts D.7.1. Serial Management Connection Serial connection of the IDR to a PC is performed by connecting the IDR's RJ-11 port to the serial port (9-pin D-type) of the PC. Table D-14: IDR serial management connector pinouts Crossover cable (PC side) Straight-through cable (IDR side) 6-Pin RJ-11 male Pin D-10 Function Rx GND Tx 9-Pin D-type female 9-Pin D-type male 9-Pin D-type female Pin Pin Pin Airspan Networks Ltd. 02030311-05 Hardw are Installation Guide Summary of Connector Pinouts D.7.2. Ethernet LAN Connection The table below describes the connector pinouts for the Ethernet cable (CAT 5) that connects the IDR’s Ethernet port to the PC’s LAN port, using an 8-pin RJ-45 connector. Table D-15: BSPS Ethernet LAN connector pinouts 8-pin RJ-45 Pin 02030311-05 Function Rx+ RxTx+ Tx- Airspan Networks Ltd. D-11 Summary of Connector Pinouts Hardware Installation Guide D.8. SDA Ethernet LAN Connector Pinouts ! For SDA-1, SDA-4H (J2, J3, J4), and SDA-4S models (also for VoIP networks): Table D-16: SDA Ethernet LAN connector pinouts Straight-through cable 8-pin RJ-45 male Pin Function +RX -RX +TX -TX For J5 port on the SDA-4H: Table D-17: SDA Ethernet LAN connector pinouts Crossover cable 8-pin RJ-45 male Pin D-12 Function +Tx -Tx +Rx -Rx Airspan Networks Ltd. 02030311-05
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2003:10:19 09:54:34 Producer : Acrobat Distiller 4.05 for Windows Modify Date : 2003:12:16 14:30:46+02:00 Page Count : 133 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools