Airspan Networks CRM3650 WiMAX terminal station User Manual Generic CRM User Guide

Airspan Networks Inc WiMAX terminal station Generic CRM User Guide

Users manual

Download: Airspan Networks CRM3650 WiMAX terminal station User Manual Generic CRM User Guide
Mirror Download [FCC.gov]Airspan Networks CRM3650 WiMAX terminal station User Manual Generic CRM User Guide
Document ID1827819
Application IDehCWnILgvRJX7uHj8aJCwA==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize98.88kB (1235960 bits)
Date Submitted2012-11-01 00:00:00
Date Available2013-02-26 00:00:00
Creation Date2012-10-31 11:34:35
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2012-10-31 12:43:36
Document TitleGeneric_CRM_User_Guide
Document CreatorMicrosoft® Word 2010
Document Author: M Falik

UGD-D00658 Rev A
CRM Module
User Guide
CRM Module User Guide
Acknowledgements
Airspan Networks Inc. acknowledges the following trademarks used within this document:
© Intel Corporation
http://www.intel.com/
© Microsoft Corporation
http://www.microsoft.com
© SEQUANS COMMUNICATIONS http://www.sequans.com
Copyright
© Copyright by Airspan Networks Inc., 2012. All rights reserved worldwide.
The information contained within this document is proprietary and is subject to all relevant
copyright, patent and other laws protecting intellectual property, as well as any specific
agreements protecting Airspan Networks Inc. rights in the aforesaid information. Neither this
document nor the information contained herein may be published, reproduced or disclosed to
third parties, in whole or in part, without the express, prior, written permission of Airspan Networks
Inc. In addition, any use of this document or the information contained herein for the purposes
other than those for which it is disclosed is strictly forbidden.
Airspan Networks Inc. reserves the right, without prior notice or liability, to make changes in
equipment design or specifications.
Information supplied by Airspan Networks Inc. is believed to be accurate and reliable. However,
no responsibility is assumed by Airspan Networks Inc. for the use thereof nor for the rights of third
parties which may be effected in any way by the use of thereof.
Any representation(s) in this document concerning performance of Airspan Networks Inc.
product(s) are for informational purposes only and are not warranties of future performance, either
expressed or implied. Airspan Networks Inc. standard limited warranty, stated in its sales contract
or order confirmation form, is the only warranty offered by Airspan Networks Inc. in relation
thereto.
This document may contain flaws, omissions or typesetting errors; no warranty is granted nor
liability assumed in relation thereto unless specifically undertaken in Airspan Networks Inc. sales
contract or order confirmation. Information contained herein is periodically updated and changes
will be incorporated into subsequent editions. If you have encountered an error, please notify
Airspan Networks Inc. All specifications are subject to change without prior notice.
Product performance figures quoted within this document are indicative and for information
purposes only.
Page 2
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Table of Contents
Acknowledgements .................................................................................................................... 2
Copyright .................................................................................................................................... 2
Table of Contents ....................................................................................................................... 3
Summary of Figures ................................................................................................................... 5
Summary of Tables .................................................................................................................... 6
Warnings and Cautions .............................................................................................................. 7
Human Exposure to Radio Frequencies ...................................................................................... 7
Radio Interference........................................................................................................................ 7
Modifications ................................................................................................................................ 7
General......................................................................................................................................... 7
Disclaimer Statement ................................................................................................................... 7
DECLARATION OF CONFORMITY .......................................................................................... 8
FCC Notice ............................................................................................................................... 10
Federal Communication Commission Notice ............................................................................. 10
Limitations - TBD........................................................................................................................ 10
Labeling Requirement ................................................................................................................ 10
Maximum Output TX Power ..................................................................................................... 11
Antenna Types ........................................................................................................................... 11
CRM Antenna Usage ............................................................................................................... 11
About this Guide ................................................................................................................ 12
1.1 Purpose ................................................................................................................................ 12
1.2 Conventions .......................................................................................................................... 12
Overview ............................................................................................................................ 13
2.1.1 Main Features ............................................................................................................... 13
2.2 WiMAX Management ............................................................................................................ 13
Installation Prerequisites ................................................................................................... 14
3.1 Package Contents ................................................................................................................ 14
Physical Description .......................................................................................................... 15
4.1 CRM ...................................................................................................................................... 15
4.1.1 Physical Dimensions ..................................................................................................... 15
4.2 Connector ............................................................................................................................. 16
Connecting the CRM Mini PCIe Module ............................................................................ 17
5.1 Typical CRM Installation ....................................................................................................... 17
Instillation of Drivers and Software .................................................................................... 19
6.1 Configuration ........................................................................................................................ 23
6.2 Connection Manager ............................................................................................................ 24
Appendix ............................................................................................................................ 25
Page 3
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
7.1 CRM – Power, Environmental, Standards Compliance........................................................ 25
7.2 Glossary of Terms ................................................................................................................ 25
7.3 Revision History .................................................................................................................... 27
7.4 Contact Information .............................................................................................................. 27
Page 4
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Summary of Figures
Figure 1 – CRM PCIe module .................................................................................................. 15
Figure 2 - Mini PCI Connector ................................................................................................. 16
Figure 3 - Typical CRM in iPro installation ............................................................................... 17
Figure 4 - Typical CRM in Pro installation ................................................................................ 18
Figure 5 - Typical CRM in MRTe installation ........................................................................... 18
Figure 6 - Setup language ....................................................................................................... 19
Figure 7 - Setup wizard ............................................................................................................ 19
Figure 8 - Select destination location ....................................................................................... 20
Figure 9 - Select start menu folder ........................................................................................... 20
Figure 10 - Additional tasks ..................................................................................................... 21
Figure 11 - Ready to install ...................................................................................................... 21
Figure 12 – Installing ................................................................................................................ 22
Figure 13 - Installation complete .............................................................................................. 22
Figure 14 – Services ................................................................................................................ 24
Figure 15 - WiMAX CM ............................................................................................................ 24
Page 5
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Summary of Tables
Table 1 - CRM FCC Maximum Output TX Power .................................................................... 11
Table 2 - CRM ETSI Maximum Output TX Power ................................................................... 11
Table 3 – Antenna Types - Technical ...................................................................................... 11
Table 4 - Antenna arrays.......................................................................................................... 11
Table 5 - Package Contents .................................................................................................... 14
Table 6 - CRM physical dimensions ........................................................................................ 15
Table 7 - Connector 52 pin, pinouts ......................................................................................... 16
Table 8 - Environment, EMC & Safety ..................................................................................... 25
Page 6
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Warnings and Cautions
Human Exposure to Radio Frequencies
The WiMAX CRM Antennas should be installed a minimum distance of 25.4 Cm for the 3.65
GHz variant from your body.
Radio Interference
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to internal
vehicle radio communications.
Please ensure a maximum separation between the CRM’s antenna and other antennas.
Modifications
Any changes and modifications to this device that are not expressly approved by Airspan
Networks are not permitted and if done will result in voidance of warranty.
General

Installation, replacement and service should be performed by qualified personnel who
are familiar with local safety codes.

Do not mount external antennas in inclement weather (such as rain or lightning) that
may increase risk of electrocution.
 CRM does not provide protection from hazard energy in case of single fault condition.

Power supply shall be limited up to 3A in normal and single fault condition.
Disclaimer Statement
The information in this document is subject to change without notice and does not represent a
commitment on the part of the vendor. No warranty or representation, either expressed or
implied, is made with respect to the quality, accuracy or fitness for any particular purpose of
this document. The manufacturer reserves the right to make changes to the content of this
document and/or the products associated with it at any time without obligation to notify any
person or organization of such changes. In no event will the manufacturer be liable for direct,
indirect, special, incidental or consequential damages arising out of the use or inability to use
this product or documentation, even if advised of the possibility of such damages. This
document contains materials protected by copyright. All rights are reserved. No part of this
manual may be reproduced or transmitted in any form, by any means or for any purpose
without expressed written consent of its authors. Product names appearing in this document
are mentioned for identification purchases only. All trademarks, product names or brand
names appearing in this document are registered property of their respective owners.
Page 7
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
DECLARATION OF CONFORMITY
European Community, Switzerland, Norway, Iceland, and Liechtenstein
Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC
English:
This equipment is in compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC.
Deutsch:
Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren
entsprecheneden Vorgaben der Richtlinie 1999/5/EU.
Dansk:
Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante
bestemmelser i Directiv 1999/5/EF.
Español:
Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la
Directive 1999/5/EC.
Greek:
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ
ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ
1999/5/ΕΚ.
Français:
Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes
de la Directive 1999/5/EC.
Íslenska:
Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB.
Italiano:
Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva
1999/5/EC.
Nederlands:
Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn
1999/5/EC.
Norsk:
Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i
EU-directiv 1999/5/EC.
Português:
Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva
1999/5/EC.
Suomalainen:
Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen
muidenkin ehtojen mukainen.
Svenska:
Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta
bestämmelser i Direktiv 1999/5/EC.
Român:
Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale
Directivei 1999/5/CE.
Page 8
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
The Declaration of Conformity related to this product can be obtained from
product_management@Airspan.com
Page 9
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
FCC Notice
Federal Communication Commission Notice
The United States Federal Communication Commission (FCC) and the Canadian Department
of Communications have established certain rules governing the use of electronic equipment.
Part 15, Class B.
This device complies with Part 15 of FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may
cause undesired operation. This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio frequency
energy, and if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.
Limitations
The CRM PCIe module is a terminal station intended for use in the Airspan outdoor CPE V70
and MRTe series.
Antenna Limitations – see Antenna Types
Labeling Requirement
Airspan CPE V70 and MRTe series label must include wording similar to the following:

“Contains FCC ID:PIDCRM3650”
Page 10
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Maximum Output TX Power
Table 1 - CRM FCC Maximum Output TX Power
Frequency
Band
FCC
TX
Antenna Gain
EIRP
3.65GHz
19.6dBm
39.1dBm
19.5dBI
3.65GHz
26.8dBm
32.4dBm
5.6dBI
Table 2 - CRM ETSI Maximum Output TX Power
Frequency
Band
TX
ETSI
3.65GHz
26dBm
Rest of the World
TX
EIRP
EIRP
45dBm
26dBm
Antenna Gain
45dBm
19dBI
Caution: Do not set maximum output TX power to higher than local regulations.
Antenna Types
Table 3 – Antenna Types - Technical
Type
Frequency range
Gain
Part number
Directional Dual-Polarized Panel
3.3-3.8 GHz
19.5dBi
07-1161-01
Direct Mount LPT Style
3.3-3.8 GHz
5.6dBi
W1982
CRM Antenna Usage
CRM has two (2) RF ports that can be connected to two single-port antennas
Note: Appropriate mounting kit (included) for the antenna(s) is required.

Dual polarized antenna with two (2) ports - connected via 2 RF jumper cables.
The following table describes the antenna arrays:
Table 4 - Antenna arrays
Frequency
Band
# of
Receivers
Sector
3.3-3.8 GHz
45º
3.3-3.8 GHz
Omni
Page 11
Antenna Type
3.3-3.8 GHz Dual Polar
Antenna - mounting included
3.3-3.8 Monopole
Commercial in Confidence
# of Antennas
UWB-D00658 Rev A
CRM Module User Guide
1 About this Guide
This section discusses the purpose, intended audience, conventions, referenced
documentation and organization for this guide.
1.1 Purpose
This User Guide is intended as an instruction manual for professional system integrators to
provide step-by-step factory integration instructions for setting up, installing and initial
configuration of the CRM Mini PCIe module. These procedures include:





System Overview
Installation Prerequisites
Physical description
Connecting
Initial Device Configurations
1.2 Conventions
Icon
Description
Checkpoint: Marks a point in the workflow where there may be an exit or
branch to some other procedure. At each Checkpoint the reason for an exit
or branch is given along with specific directions to locate the entry point in the
other procedure.
Reference: Gives a resource in the workflow that may be needed to complete
a procedure along with specific directions to use the resource.
Caution: Describes a possible risk and how to lessen or avoid the risk.
Advice: Provides a recommendation based on best practice.
Note: Provides useful information.
Page 12
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
2 Overview
The Airspan CRM Mini PCIe module is a product specific WiMAX module designed to be
embedded in Airspan MiMAX Pro, iPro and MRTe products allowing WiMAX connectivity. The
Wireless protocols that come with this product ensure data security and isolation from
interference generated by other radio frequencies.
The CRM module supports MIMO antenna technology and high power output.
2.1.1 Main Features
The Airspan WiMAX CRM Mini PCIe module provides the following main features:

Based on the WiMAX IEEE 802.16e wireless technology.
2.2 WiMAX Management

Software is upgraded locally and remotely.

Designed for local and remote management via the Host processor.
Page 13
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
3 Installation Prerequisites
Before installing your CRM, read the following:
3.1 Package Contents
Examine the Airspan WiMAX CRM shipping container. If you notice any damage, or missing
items as listed in the Packing List, immediately notify the carrier that delivered the unit and
contact an Airspan representative.
The CRM kit should contain the following items:

CRM Mini PCIe Module
Table 5 - Package Contents
Name
Quantity
CRM
10
Page 14
Comments
Image
PCIe module
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Physical Description
This section provides a description of the components of the CRM installation:

Dimensions

Connector
4.1 CRM
The CRM Mini PCIe module
Figure 1 – CRM PCIe module
4.1.1 Physical Dimensions
The table below lists the physical dimensions of the CRM Mini PCIe module.
Table 6 - CRM physical dimensions
Parameter
Value
Dimensions (W x L x
H)
PCIe Mini-Card Form Factor:
W: 51 mm (2.01”) (including PCIe connector);
L: 70 mm (2.36”)
H: 5 mm (0.228”) (not including RF connectors)
Weight
Page 15
0.1 Kg Approx. (100 grams Approx.)
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
4.2 Connector
The connector is described below:
Figure 2 - Mini PCI Connector
Table 7 - Connector 52 pin, pinouts
Pin
Signal
5.5V
Pin
Signal
26
GND
27
GND
28
GND
29
30
31
32
33
34
GND
10
35
GND
11
36
12
37
13
38
14
39
5.5V
40
GND
16
41
5.5V
17
42
15
18
GND
GND
GND
GND
43
19
44
20
45
21
GND
47
23
48
25
Page 16
5.5V
GND
46
22
24
GND
49
50
GND
51
SQN_RST
52
5.5V
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
5 Connecting the CRM Mini PCIe Module
Note: Carefully remove the CRM Mini PCIe module from the packaging box
Caution: It is the responsibility of the person installing the CRM module to
ensure that only those antennas certified for use with the product are used.
The use of any antenna other than those certified with the product is
expressly forbidden.
Caution: The CRM module and the antennas must be installed only by
experienced installation professionals who are familiar with the local safety
codes and are licensed by the appropriate government authorities.
To connect the CRM Module:
1. Make sure the unit is turned off. Remove the cover from the unit.
2. Carefully slide the CRM Mini PCIe module into the mini PCI slot. Align the pins and push
evenly and slowly and ensure it is properly seated.
3. After the device has been connected, Windows will detect the module and you will be
prompted to install the software and drivers.
5.1 Typical CRM Installation
The following displays a typical installation with the CRM Mini PCIe module installed.
Figure 3 - Typical CRM in iPro installation
Page 17
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Figure 4 - Typical CRM in Pro installation
Figure 5 - Typical CRM in MRTe installation
Page 18
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
6 Instillation of Drivers and Software
1. Exit all Windows programs. After recognizing the USB connection installation will initiate
automatically.
2. When prompted select the language to use during the installation.
Figure 6 - Setup language
3. Click OK to continue.
4. The Setup Wizard will walk you through the process.
Figure 7 - Setup wizard
5. Click Next to continue.
Page 19
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Figure 8 - Select destination location
6. Click Next to continue.
Figure 9 - Select start menu folder
7. Click Next to continue.
Page 20
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Figure 10 - Additional tasks
8. Select additional tasks, if required.
9. Click Next to continue.
Figure 11 - Ready to install
Page 21
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
10. Click Install to continue installation
Figure 12 – Installing
11. Wait while installation continues.
Figure 13 - Installation complete
Page 22
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
12. After Installation is complete click Finish.
6.1 Configuration
1. Navigate to the sequansd.xml file location C:\Program Files\Sequans Communication
which is used to configure frequency, bandwidth, etc. as shown below:

-


- 127.0.0.1 7771
10 

- Firmwares 

- -  




none 

- fine:* SequansdLog.txt
 
2. Edit file as required.
Note: Contact Customer support for specific editing instructions.
3. After editing file, you need to restart sequansd service, as follows:
Navigate to - Start > settings > control panel > Administrative tools > Services
4. Choose service sequansd, right click > restart, as shown below:
Page 23
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
Figure 14 – Services
6.2 Connection Manager
Sequans Connection Manager - program which runs on the host to monitor the WiMAX link.
Navigate to - Start > Programs > Sequans Communications > Sequans CM
Figure 15 - WiMAX CM
The CM displays the downlink signal strength, uplink and downlink throughput counter:

Enable radio – check to enable radio

Link Status – displays current link status, such as:

Downlink

Uplink

Tools

Advanced
Page 24
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
7 Appendix
7.1 CRM – Power, Environmental, Standards Compliance
Table 8 - Environment, EMC & Safety
Environmental
Input
5.5 VDC +/- 0.3 VDC through PCIe
DC Power Consumption
5.79 W
Operating Temperature
-40°C to +85°C
Operating Humidity
5% - 95%, non-condensing
EMC
FCC Part 15, Subpart B, Class B. According to
FCC only class A is required for outdoor unit
device.
Radio
FCC Part 90, FCC Part 27
MTBF
123 years (1,078,662 hours)
7.2 Glossary of Terms
CL-MIMO
Closed Loop MIMO
ESD
Electro Static Discharge
FCC
Federal Communications Commission
FUSC
Full Usage of Sub-channels
JTAG
Joint Test Action Group
LED
Light Emitting Diode
LNA
Low Noise Amplifier
MIMO
Multiple Inputs Multiple Outputs
MIMO-SM
MIMO Spatial Multiplexing
MRC
Maximum Ratio Combining
PA
Power Amplifier
PCI
Peripheral Component Interconnect
PHY
Physical Layer
PUSC
Partial Usage of Sub-channels
RF
Radio Frequency
Rx
Receive
SPI
Serial Peripheral Interface
CRM
SS Radio Module
STC
Space Time Coding
TP
Test Point
Tx
Transmit
Page 25
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
UART
Universal Asynchronous Receiver/Transmitter
USB
Universal Serial Bus
WiMAX
WiMAX is a wireless industry coalition whose members are organized to
advance IEEE 802.16 standards for broadband wireless access (BWA)
networks.
Page 26
Commercial in Confidence
UWB-D00658 Rev A
CRM Module User Guide
7.3 Revision History
Revision
Originator
Date
Description
Rev A
M. Falik
10-2012
Initial document
7.4 Contact Information
Customer Service Help-Desk for customer service emergency
Airspan Networks have introduced the Airspan Tracker application to enable prompt and efficient
Customer Support services.
If you do not have an Airspan Tracker account, please obtain login credentials by filling-in the
form in the main page "Register New Account".
Worldwide Headquarters:
Airspan Networks Inc.
777, Yamato Road, Suite 310,
Boca Raton, FL 33431, USA
Tel: +1 561 893 8670
www.airspan.com
Feedback:
To provide feedback on this document, please send comments to the following email address:
documentfeedback@airspan.com
Page 27
Commercial in Confidence
UWB-D00658 Rev A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : M Falik
Create Date                     : 2012:10:31 11:34:35+02:00
Modify Date                     : 2012:10:31 12:43:36+02:00
Subject                         : CRM
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : M Falik
Title                           : Generic_CRM_User_Guide
Description                     : CRM
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2012:10:31 12:43:36+02:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:94368f3d-d8a1-425f-9ea8-9204758817eb
Instance ID                     : uuid:946e71c4-8af7-484f-9042-93ce78647689
Page Count                      : 27
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PIDCRM3650

Navigation menu