        UGD-D01001 Rev B  AirSynergy 2000 Installation Guide
 AirSynergy 2000 Installation Guide     Page 2  Commercial in Confidence  UGD-D01001 Rev B Copyright   © Copyright by Airspan Networks Inc., 2014. All rights reserved worldwide. The information contained within this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Inc. rights in the aforesaid information. Neither this document nor the information contained herein may be published, reproduced or disclosed to third parties, in whole or in part, without the express, prior, written permission of Airspan Networks Inc. In addition, any use of this document or the information contained herein for the purposes other than those for which it is disclosed is strictly forbidden. Airspan Networks Inc. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by Airspan Networks Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Airspan Networks Inc. for the use thereof nor for the rights of third parties which may be effected in any way by the use of thereof. Any representation(s) in this document concerning performance of Airspan Networks Inc. product(s) are for informational purposes only and are not warranties of future performance, either expressed or implied. Airspan Networks Inc. standard limited warranty, stated in its sales contract or order confirmation form, is the only warranty offered by Airspan Networks Inc. in relation thereto. This document may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in relation thereto unless specifically undertaken in Airspan Networks Inc. sales contract or order confirmation. Information contained herein is periodically updated and changes will be incorporated into subsequent editions. If you have encountered an error, please notify Airspan Networks Inc. All specifications are subject to change without prior notice. Product performance figures quoted within this document are indicative and for information purposes only.
 AirSynergy 2000 Installation Guide     Page 3  Commercial in Confidence  UGD-D01001 Rev B Table of Contents Copyright .......................................................................................................................................... 2 Table of Contents ............................................................................................................................. 3 Summary of Figures ......................................................................................................................... 5 Summary of Tables .......................................................................................................................... 7 Warnings and Cautions .................................................................................................................... 8 Human Exposure to Radio Frequencies ...................................................................................... 8 Radio Interference ........................................................................................................................ 8 Avoiding Radio Interference ......................................................................................................... 8 Modifications ................................................................................................................................. 8 General ......................................................................................................................................... 8 Safety ............................................................................................................................................ 8 Warning of Hazardous Voltages ............................................................................................... 9 Adherence to European Directive 1999/519/EC .......................................................................... 9 Warning Symbols.......................................................................................................................... 9 Service Information ....................................................................................................................... 9 UL Information ............................................................................................................................ 10 Lightning Protection .................................................................................................................... 10 DECLARATION OF CONFORMITY ............................................................................................... 11 FCC Notice ..................................................................................................................................... 12 Federal Communication Commission Notice ............................................................................. 12 GPS Compliance ........................................................................................................................ 12 Maximum Output TX Power ........................................................................................................... 13 Power Consumption ................................................................................................................... 13 Antenna Types............................................................................................................................ 13 Switched Beam Antenna ............................................................................................................ 14 Front Mount Sector Antenna ...................................................................................................... 14 Omni - Blade Antenna ................................................................................................................ 16 AirSynergy Antenna Usage Options ....................................................................................... 16 1 About this Guide ..................................................................................................................... 18 1.1 Purpose .......................................................................................................................... 18 1.2 Intended Audience .......................................................................................................... 18 1.3 Conventions .................................................................................................................... 18 1.4 Referenced Documentation ............................................................................................ 18 1.5 Organization of this Guide .............................................................................................. 18 2 Introduction ............................................................................................................................. 20 2.1 AirSynergy ...................................................................................................................... 20 2.1.1 Deployment Description.......................................................................................... 20 3 Getting Started ........................................................................................................................ 22
 AirSynergy 2000 Installation Guide     Page 4  Commercial in Confidence  UGD-D01001 Rev B 3.1 Workflow of Installation ................................................................................................... 22 3.2 AirSynergy Installation Checklist .................................................................................... 23 4 Verify Prerequisites................................................................................................................. 24 4.1 Verify Site Requirements ................................................................................................ 24 4.2 Verify Installation Requirements ..................................................................................... 24 4.2.1 Verify the Tools ....................................................................................................... 24 4.2.2 Verify the Parts and Kits ......................................................................................... 24 4.2.2.1 Power Supply .......................................................................................................... 26 4.2.3 Verify Components ................................................................................................. 26 4.2.4 Physical Dimensions ............................................................................................... 29 4.2.5 Environmental ......................................................................................................... 30 5 Install AirSynergy .................................................................................................................... 31 5.1 Pole Mount Assembly ..................................................................................................... 31 5.2 Wall Mount Assembly ..................................................................................................... 32 5.3 Front Sector Antenna Assembly ..................................................................................... 33 5.4 Connecting GPS Antenna to AirSynergy ........................................................................ 34 5.5 Securing AirSynergy to the Mounting Plate .................................................................... 36 5.6 Front Mount Antenna Tilt Adjustment ............................................................................. 37 5.7 LED Display .................................................................................................................... 38 6 Connect and Manage Cables ................................................................................................. 39 6.1 Connecting the Ground Cable ........................................................................................ 39 6.2 Connecting RF Jumper Cables to External Antenna ...................................................... 40 6.3 Connecting the DC Power Cable to AirSynergy ............................................................. 40 7 Power System Connection ..................................................................................................... 42 7.1 Required Tools ............................................................................................................... 42 7.2 Cable Connections ........................................................................................................... 42 7.2.1 DC Power Cable Installation ................................................................................... 42 7.2.2 Network Cable Installation ...................................................................................... 43 7.3 Wiring DC Power Cable to the PSU ............................................................................... 44 7.4 Connecting the AC/DC PSU to Power Supply ............................................................... 46 8 Appendix A ............................................................................................................................. 48 Review Job Sheet ....................................................................................................................... 48 9 Appendix B - Glossary of Terms - Acronym, Abbreviations & Definitions .............................. 49 10 Appendix C - Installation Checklist ..................................................................................... 51 11 Appendix D – PSU for USA ................................................................................................ 52 12 Appendix E ......................................................................................................................... 53 12.1 Revision History .............................................................................................................. 53 12.2 Contact Information ........................................................................................................ 53
 AirSynergy 2000 Installation Guide     Page 5  Commercial in Confidence  UGD-D01001 Rev B Summary of Figures Figure 1 - AirSynergy with sunshield .............................................................................................. 16 Figure 2 - AirSynergy with front sector antenna ............................................................................. 17 Figure 3 - AirSynergy with switched beam antenna ....................................................................... 17 Figure 4 - AirSynergy 2000 assembled with: Front Mount antenna, sunshield, SBA and sunshield ........................................................................................................................................................ 21 Figure 5 - Workflow of Installation .................................................................................................. 22 Figure 6 - AirSynergy Unit, bottom termination .............................................................................. 28 Figure 7 - AirSynergy Unit, RF ports, Internal Duplexers ............................................................... 28 Figure 8 - AirSynergy Unit, RF ports .............................................................................................. 29 Figure 9 - AirSynergy Unit, RF ports, External Duplexers .............................................................. 29 Figure 10 - AirSynergy mounting plate and hardware .................................................................... 31 Figure 11 - Assemble clamp bands (2 required) ............................................................................ 31 Figure 12 – press down locking mechanism .................................................................................. 32 Figure 13 – tighten clamp bands .................................................................................................... 32 Figure 14 – mounting plate installed on large diameter pole ......................................................... 32 Figure 15 - positioning wall mounting plate .................................................................................... 33 Figure 16 - wall mounting plate fastened on wall ........................................................................... 33 Figure 17 - attaching front mounted antenna to mounting plate .................................................... 34 Figure 18 – Attaching front mount antenna assembly to AirSynergy ............................................. 34 Figure 19 - attaching GPS antenna to mounting bracket ............................................................... 35 Figure 20 - Attaching the GPS antenna assembly to AirSynergy .................................................. 36 Figure 21 - Lift unit to top of mounting plate ................................................................................... 36 Figure 22 - unit engages into slots on the top of mounting plate ................................................... 36 Figure 23 - lift the unit until the bottom studs fit into the bottom slots ............................................ 37 Figure 24 - AirSynergy unit engaged into the bottom slots ............................................................ 37 Figure 25 - tilt adjustment body ...................................................................................................... 37 Figure 26 - tilt adjustment antenna ................................................................................................. 38 Figure 27 – attaching ground cable to AirSynergy ......................................................................... 39 Figure 28 - attach ground cable to pole .......................................................................................... 39 Figure 29 - Connecting RF cable .................................................................................................... 40 Figure 30 - weather-proof the connection - external antenna ........................................................ 40 Figure 31 - attaching power cable to AirSynergy ........................................................................... 41 Figure 32 - required tools ............................................................................................................... 42 Figure 33 - DC Power connection .................................................................................................. 43 Figure 34 - Power connection - AirSynergy bottom panel .............................................................. 43 Figure 35 - power and network cable overview .............................................................................. 44 Figure 36 - Waterproof connector exploded view ........................................................................... 44 Figure 37 - power cable preparation............................................................................................... 44
 AirSynergy 2000 Installation Guide     Page 6  Commercial in Confidence  UGD-D01001 Rev B Figure 38 - waterproof connector separated .................................................................................. 44 Figure 39 - gland and connector on cable ...................................................................................... 45 Figure 40 - secure cable to connector ............................................................................................ 45 Figure 41 – power cable wires assembled ..................................................................................... 45 Figure 42 - numbered connector contacts ...................................................................................... 45 Figure 43 - assemble and tighten ................................................................................................... 45 Figure 44 - PSU cable connector assembly ................................................................................... 46 Figure 45 - PSU wires assembled .................................................................................................. 46 Figure 46 - assemble and tighten ................................................................................................... 46 Figure 47 - connector assembled and tightened ............................................................................ 46 Figure 48 - High power (240W) PSU – used for dual AirSynergy installations .............................. 46 Figure 49 - Standard power (150W) PSU – used for standard AirSynergy installation ................. 46 Figure 50 - attaching PSU .............................................................................................................. 47 Figure 51 - PSU for USA deployment ............................................................................................ 47 Figure 52 - PSU for USA ................................................................................................................ 52 Figure 53 - Inside PSU with cable terminations ............................................................................. 52
 AirSynergy 2000 Installation Guide     Page 7  Commercial in Confidence  UGD-D01001 Rev B Summary of Tables Table 1 - AirSynergy FCC Maximum Output TX Power ................................................................. 13 Table 2 - AirSynergy ETSI Maximum Output TX Power ................................................................ 13 Table 3 - Switched Beam Antenna Parameters - Directional Mode ............................................... 14 Table 4 - Switched Antenna Parameters - Omni Mode .................................................................. 14 Table 5 - Front Mounted Sector Antenna Parameters ................................................................... 16 Table 6 – Omni - Blade Antenna Parameters ................................................................................ 16 Table 7 - AirSynergy installation tools ............................................................................................ 24 Table 8 - AirSynergy installation parts and kits .............................................................................. 24 Table 9 - External Antenna and feeder kits (Optional) ................................................................... 26 Table 10 - AirSynergy additional items ........................................................................................... 26 Table 11 - AirSynergy components ................................................................................................ 26 Table 12 - AirSynergy physical dimensions ................................................................................... 29 Table 13 - AirSynergy Environment Compliance ........................................................................... 30 Table 14 - LED Display ................................................................................................................... 38 Table 15 - Glossary of Terms ......................................................................................................... 49 Table 16 - Checklist for Procedure ................................................................................................. 51
 AirSynergy 2000 Installation Guide     Page 8  Commercial in Confidence  UGD-D01001 Rev B Warnings and Cautions Human Exposure to Radio Frequencies The AirSynergy antennas should be installed and operated from a minimum safe distance of:   AirSynergy with External Antenna: 1.5m   AirSynergy with Front Mount Antenna: 1.0m   AirSynergy with Smart Beam Antenna (SBA): 0.5m  Radio Interference This AirSynergy generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the technician is encouraged to try to correct the interference by performing one or more of the following measures:  Re-orientate or relocate the antenna    Increase separation between the eNodeBs and/or End Device   Connect the equipment to an outlet on a circuit different from that to which the power source is connected Avoiding Radio Interference  Ensure a minimum of 1-meter separation between co-located antennas of AirSynergy units. Modifications Any changes and modifications to this device that are not expressly approved by Airspan Networks may void the user's authority to operate the equipment. General   Only qualified personnel should be allowed to install, replace, and service the equipment.   The device cannot be sold retail, to the general public or by mail order. It must be sold to operators.   Installation must be controlled.   Installation must be performed by licensed professionals.   Installation requires special training. The AirSynergy radio and antenna should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void Airspan's product warranty and may expose the end user or the service provider to legal and financial liabilities. Airspan and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas. Safety  1.  Read this guide and follow all operating and safety instructions. 2.  Keep all product information for future reference. 3.  This product is supplied with a grounding power plug. Do not defeat this important safety feature. 4. Warning: High voltages exist inside the product - do not remove the lid or base: No user serviceable parts inside. 5.  Position the power cord to avoid possible damage; do not overload wall outlets.
 AirSynergy 2000 Installation Guide     Page 9  Commercial in Confidence  UGD-D01001 Rev B 6.  Do not place this product on or near a direct heat source, and avoid placing objects on the terminal. 7.  To avoid electrical shock do not install this device during adverse conditions such as rain or inclement weather. 8.  Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the power before cleaning. 9.  The units should not be located near power lines or other electrical power circuits. 10.  The radio transceiver must be properly grounded to protect against power surges and accumulated static electricity. It is the user’s responsibility to install this device in accordance with the local electrical codes.  11.  Installation of the AirSynergy must be contracted to a professional installer.  12.  Disconnect Device. The socket outlet should be easily accessible in case you have to disconnect the device. 13.  When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. Warning of Hazardous Voltages On AC installations, hazardous voltages exist.  Use caution when verifying or working with AC power.  Remove metal jewelry that could come into contact with AC power. On DC sections, short circuiting the low voltage, low impedance circuits can cause severe arcing that may result in burns or eye damage.  Remove rings, watches etc. to avoid shorting DC circuits.   Note: Airspan products do not contain hazardous substances (as defined in UK Control of Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990).  At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements.  Adherence to European Directive 1999/519/EC European Council Recommendation 1999/519/EC details basic restrictions and reference levels on human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these recommended restrictions and reference levels should provide a high level of protection as regards the established health effects that may result from exposure to electromagnetic fields. Warning Symbols The following symbols may be encountered during installation or troubleshooting. These warning symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters. Familiarize yourself with standard safety practices before continuing.   Electro-Magnetic Radiation High Voltage Service Information Refer all repairs to qualified service personnel. Do not remove the covers or modify any part of this device, as this will void the warranty.
 AirSynergy 2000 Installation Guide     Page 10  Commercial in Confidence  UGD-D01001 Rev B Disconnect the power to this product and return it for service if the following conditions apply: a.  The terminal does not function after following the operating instructions outlined in this manual. b.  Liquid has been spilled, a foreign object is inside, or the terminal has been exposed to rain. c.  The product has been dropped or the housing is damaged. Locate the serial number of the terminal, antenna, and transceiver and record these on your registration card for future reference. Use the space below to affix serial number stickers. Also record the MAC address, located on the back of the terminal. UL Information - The equipment must be properly grounded according with NEC and other local safety code requirements. - Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as is practical. - AirSynergy is designed to operate in environmental conditions complying with IP66 and relevant standards. Lightning Protection WARNING: The following notes are general recommendations for the system. The wireless equipment should be installed by a qualified professional installer and must follow local and national codes for electrical grounding and safety. Failure to meet safety requirements and/or use of non-standard practices and procedures could result in personal injury and damage to equipment. A direct lightning strike may cause serious damage even if these guidelines are followed. All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced current from a near strike. Lightning protection and grounding practices in local and national electrical codes serve to minimize equipment damage, service outages, and serious injury. Reasons for lightning damage are summarized as: - Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment. - Lack of properly installed lightning protection equipment that can cause equipment failures from lightning induced currents. A lighting protection system provides a means by which the energy may enter earth without passing through and damaging parts of a structure. A lightning protection system does not prevent lightning from striking; it provides a means for controlling it and preventing damage by providing a low resistance path for the discharge of energy to travel safely to ground. Improperly grounded connections are also a source of noise that can cause sensitive equipment to malfunction. A good tower grounding system disperses most of the surge energy from a tower strike away from the building and equipment. To limit the equipment damage due to a lightning strike, the following practices are recommended for the wireless system: - Provide direct grounding from the antenna mounting bracket, the radio and antenna and the lightning/surge protectors to the same ground point at the base of the tower or a ground bus on the building. Use the grounding screws on the antenna bracket and the radio and antenna for terminating the ground wires. - The AC wall outlet ground must be connected to the same grounding system as the eNodeB.
 AirSynergy 2000 Installation Guide     Page 11  Commercial in Confidence  UGD-D01001 Rev B DECLARATION OF CONFORMITY European Community, Switzerland, Norway, Iceland, and Liechtenstein  Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC English:  This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.  Deutsch:  Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie 1999/5/EU.   Dansk:  Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF.   Español:  Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC.   Greek:  ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.   Français:  Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC.   Íslenska:  Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB.   Italiano:  Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC.   Nederlands:  Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC.   Norsk:  Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC.   Português:  Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.   Suomalainen:  Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen.   Svenska:  Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC. Român: Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei 1999/5/CE.  The Declaration of Conformity related to this product can be obtained from PLM@Airspan.com.
 AirSynergy 2000 Installation Guide     Page 12  Commercial in Confidence  UGD-D01001 Rev B FCC Notice Federal Communication Commission Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. Fixed and base stations transmitting a signal with an emission bandwidth greater than 1 MHz must not exceed an EIRP of 1000 watts/MHz and an antenna height of 305 m HAAT, except that antenna heights greater than 305 m HAAT are permitted if power levels are reduced below 1000 watts/MHz EIRP. GPS Compliance  The GPS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC." The GPS complies with the following EMC Common Regulatory Testing standards:   EN55022: Radiated and Conducted Emissions   CISPR 22: Class B   EN 50081-1: Generic Emissions Class B   EN 50082-1: Generic Immunity Class B   EN 61000-4-2: Electrostatic Discharge Immunity   EN 61000-4-3: Radiated RF EM Field Immunity Test   EN 61000-4-4: Electrical Fast Transient/Burst Test   EN 61000-4-6: Conducted Immunity   EN 61000-4-8: Magnetic Field Immunity  Note: A GPS is recommended for synchronizing between LTE sectors.   Note: An optional GPS Lightning/Surge protector is available from Airspan for lightning prone deployments.
 AirSynergy 2000 Installation Guide     Page 13  Commercial in Confidence  UGD-D01001 Rev B Maximum Output TX Power Table 1 - AirSynergy FCC Maximum Output TX Power Frequency Band FCC TX                  EIRP Antenna Gain 728-746 MHz 33.68dBm 47.18dBm 13.5dBi 2110-2170 MHz 33.48dBm 50.48dBm 17.0dBi 2496-2690MHz 33.65dBm 51.65dBm 18.0dBi 2620-2690MHz 33.36dBm 51.36dBm 18.0dBi 3650-3675MHz 34.91dBm 36.91dBm 2.0dBi 3650-3675MHz 18.91dBm 36.91dBm 18.0dBi  Table 2 - AirSynergy ETSI Maximum Output TX Power Frequency Band ETSI TX                EIRP Antenna Gain 728-746 MHz 33dBm 46.5dBm 13.5dBi  2110-2170 MHz 33dBm 50dBm 17.0dBi 2496-2690MHz 33dBm 51dBm 18.0dBi 2560-2630 MHz 33dBm 51dBm 18.0dBi 2620-2690 MHz 33dBm 51dBm 18.0dBi 3400-3500 MHz 33dBm 51dBm 18.0dBi 3650-3675MHz 33dBm 35dBm 2.0dBi 3650-3675MHz 33dBm 51dBm 18.0dBi   Caution: Do not set maximum output TX power to higher than local regulations. Power Consumption AirSynergy has a Max nominal power consumption of 78W. AirSynergy power consumption is described in the following table: Duplex Tx Power at RF Port (dBm) Nominal Power Consumption (W) Power Supply Requirement (W) FDD 30 80 120 TDD 30 78 120 Antenna Types The following antennas are designed specifically for AirSynergy deployments. Externally mounted antennas are available for use as well, but are specified separately.  Note: For a list of compatible external antennas, please contact your nearest Airspan sales representative.
 AirSynergy 2000 Installation Guide     Page 14  Commercial in Confidence  UGD-D01001 Rev B Switched Beam Antenna Switched Beam antenna (with built-in GPS antenna) variant include a top mounted steerable antenna with the following specification. The antenna is a multi-element cross polarized (dual slant) design which can be used in directional or omni modes of operation. Table 3 - Switched Beam Antenna Parameters - Directional Mode Parameter 698 MHz 698 MHz 23xx MHz 25xx MHz 34xx MHz Frequency 698 – 806 MHz 698 – 806 MHz 2300 - 2500 MHz 2500 - 2700 MHz 3400 - 3700 MHz Polarization Dual Slant ±45 Dual Slant ±45 Dual Slant ±45 Dual Slant ±45 Dual Slant ±45 Polarization discrimination -14 dB -14 dB -14 dB -14 dB -14 dB Boresight gain 12.5 dBi 13.5 dBi 8 dBi 8 dBi 9 dBi Azimuth HPBW 90±10 60±10 90±10 90±10 90±10 Elevation HPBW 17 17 20 20 20 Co & X-Pol RPE EN302-326-3 Class DN1 EN302-326-3 Class DN1 EN302-326-3 Class DN1 EN302-326-3 Class DN1 EN302-326-3 Class DN1 Grounding DC GND DC GND DC GND DC GND DC GND  Table 4 - Switched Antenna Parameters - Omni Mode Parameter 698 MHz 698 MHz 23xx MHz 25xx MHz 34xx MHz Frequency 698 – 746 MHz 746 – 806 MHz 2300 - 2500 MHz 2500 - 2700 MHz 3400 - 3700 MHz Polarization Linear Vertical Linear Vertical Dual Slant ±45 Dual Slant ±45 Dual Slant ±45 Polarization discrimination -15dB (max) -15dB (max) -16 dB -16 dB -16 dB Average gain 6.0 dBi 6.5 dBi 2 dBi 2 dBi 3.5 dBi Minimum gain ripple 5.4 dBi 5.8 dBi 4.5 dBi 4.5 dBi 4.5 dBi Elevation HPBW 19±1,5 17 20 20 20 Co & X-Pol RPE EN 302-326-3 EN 302-326-3 EN 302-326-3 EN 302-326-3 EN 302-326-3 Grounding DC GND DC GND DC GND DC GND DC GND Front Mount Sector Antenna The front mounted sector antenna is a cross polarized fixed antenna which mounts on the front of the unit in place of the sun-shield.  Note: When using a front mounted antenna, external antennas cannot be used.
 AirSynergy 2000 Installation Guide     Page 15  Commercial in Confidence  UGD-D01001 Rev B
 AirSynergy 2000 Installation Guide     Page 16  Commercial in Confidence  UGD-D01001 Rev B Table 5 - Front Mounted Sector Antenna Parameters Parameter 23xx MHz 33xx MHz 33xx MHz Frequency 2300 – 2700 MHz 3300 – 3800 MHz 3300 – 3800 MHz Polarization Dual Slant ±45 Dual Slant ±45 Double Dual Linear ±45 Polarization discrimination >18 dB >15 dB N/A Boresight gain 12 dBi 11.5 dBi 17±0.5 dBi (min) Azimuth HPBW 63 65 65 (typ) Elevation HPBW 21 22 7.5 (typ) Grounding DC GND DC GND DC GND Omni - Blade Antenna Table 6 – Omni - Blade Antenna Parameters Parameter 36xx MHz Frequency 3600 - 4000 MHz Polarization Linear (vertical) Cross Polar 20 dB Approx. Gain 2 dBi Beamwidth 360 (Az. X 70 (El.) Approx. Grounding DC GND AirSynergy Antenna Usage Options AirSynergy  comes in a range of frequency variants that can be mounted with different antenna options and formats.  Figure 1 - AirSynergy with sunshield A typical sector installation will have a cross-polar sector antenna fitted directly to the front of the AirSynergy main unit. (This is attached instead of the sun-shield).
 AirSynergy 2000 Installation Guide     Page 17  Commercial in Confidence  UGD-D01001 Rev B  Figure 2 - AirSynergy with front sector antenna A switched beam antenna version with built in GPS antenna allows for versatile LTE access, selecting between omni and n x 90 antenna patterns.  Figure 3 - AirSynergy with switched beam antenna   Note: Appropriate mounting kit (included) for the various external antennas is required.
 AirSynergy 2000 Installation Guide     Page 18  Commercial in Confidence  UGD-D01001 Rev B 1  About this Guide This section discusses the purpose, intended audience, conventions, referenced documentation and organization for this guide. 1.1 Purpose This guide provides the workflow and step-by-step procedures for Installing the AirSynergy.  These procedures include:   Verify prerequisites   Install the AirSynergy radio equipment   Install the PSU equipment (optional)   Connect and manage cables 1.2 Intended Audience This guide is intended for persons who are responsible for installing the AirSynergy equipment. These persons should have a working knowledge of the equipment. 1.3  Conventions This document uses the following informational conventions. Icon Description    Checkpoint:  Marks a point in the workflow where there may be an exit or branch to some other procedure.  At each Checkpoint the reason for an exit or branch is given along with specific directions to locate the entry point in the other procedure.   Reference:  Gives a resource in the workflow that may be needed to complete a procedure along with specific directions to use the resource.   Caution:  Describes a possible risk and how to lessen or avoid the risk.   Advice:  Provides a recommendation based on best practice.    Note:  Provides useful information. 1.4  Referenced Documentation   AirSynergy 2000 Hardware Product Specification   AirSynergy Overview Guide (pending)   AirSynergy LTE Commissioning Manual 1.5  Organization of this Guide This guide is organized into the following Sections:   About this Guide   Introduction   Getting Started   Verify prerequisites
 AirSynergy 2000 Installation Guide     Page 19  Commercial in Confidence  UGD-D01001 Rev B   Install  AirSynergy   Install the PSU equipment (Optional)   Connect and manage cables   Power System Connection   Appendixes
 AirSynergy 2000 Installation Guide     Page 20  Commercial in Confidence  UGD-D01001 Rev B 2  Introduction This section provides a descriptive overview of the Airspan’s AirSynergy Pico eNodeB and its place in the product suite. 2.1  AirSynergy AirSynergy is part of Airspan’s carrier-class 4G Pico eNodeB family. AirSynergy supports 3GPP’s Long Term Evolution (LTE) eNodeB, providing high-speed data and mobility, in order to meet the demands of the Broadband Wireless Access market. AirSynergy is a compact, easy to install pico-cell, allowing an operator to deploy LTE broadband services using existing Street Furniture (e.g. street lamps, power poles, etc…) AirSynergy employs Software Defined Radio (SDR) technology, together with two transmit and receive paths, antennas and a GPS receiver - all in a highly integrated, physically small and light, All-Outdoor package, targeted to blend seamlessly into the urban environment. This very compact outdoor product minimizes physical footprint, power consumption and operator OPEX. AirSynergy supports a wide array of frequencies and channel sizes, able to operate in both licensed and unlicensed bands with more frequencies and channel sizes added regularly. AirSynergy implements dual 30dBm (2 x 1W) transmitters, with several optional integral antennas and external antennas connectivity. All Airspan eNodeB products, including AirSynergy, are interoperable with a rich portfolio of 3rd party end user devices, including many handsets, indoor UEs, outdoor UEs and USB dongles from several ODMs, using various chipsets. For an updated of interoperability list, please contact your nearest Airspan Sales Representative.  Note: For management please refer to the AirSynergy LTE Commissioning Manual as well as the Netspan User Manual. 2.1.1  Deployment Description A highly flexible and scalable 4G Base Station, the AirSynergy is capable of supporting LTE profiles across multiple frequency bands.  Note: The following is for illustration only; actual layout may differ as infrastructure is installation-specific.   Note: AirSynergy must be properly grounded according with NEC and other local safety code requirements.   Note: Installation of the GPS Lightning/Surge protector (ordered separately) is necessary to protect the GPS antenna. The Lightning/Surge protector must be properly grounded with NEC and other local safety code requirements.   Note: An External Duplexer is required for some lower frequency (<1GHz) FDD variants (supplied with AirSynergy, where required).
 AirSynergy 2000 Installation Guide     Page 21  Commercial in Confidence  UGD-D01001 Rev B  Figure 4 - AirSynergy 2000 assembled with: Front Mount antenna, sunshield, SBA and sunshield    Note: Auto-negotiation must always be enabled on the core network side.    Note: Illustration above display the GPS connected directly to the top of the unit, there is also a remote GPS antenna option.
 AirSynergy 2000 Installation Guide     Page 22  Commercial in Confidence  UGD-D01001 Rev B 3  Getting Started 3.1  Workflow of Installation The Workflow to install the AirSynergy is shown in the following diagram:  Figure 5 - Workflow of Installation   Caution:  Antennas must be connected and attached before AirSynergy is powered on.
 AirSynergy 2000 Installation Guide     Page 23  Commercial in Confidence  UGD-D01001 Rev B 3.2  AirSynergy Installation Checklist Plan the installation of the AirSynergy by using the Installation Checklist, which you can find as a removable job aid in Appendix A for this guide.
 AirSynergy 2000 Installation Guide     Page 24  Commercial in Confidence  UGD-D01001 Rev B 4  Verify Prerequisites Prior to installing the AirSynergy, verify the required safety, power, tools, parts and components.  Reference: Set up requirements for the installation is detailed in the Job Sheet, see Appendix A for this guide. 4.1  Verify Site Requirements To set up the AirSynergy, an IP connection to a Netspan server is required. 4.2  Verify Installation Requirements 4.2.1  Verify the Tools   Note: AirSynergy variants with Sunshield, front mounted and Switched Beam antennas come pre-assembled from the production line.  Table 7 - AirSynergy installation tools Tool Use Large flat bladed screwdriver  securing the pole straps 13mm wrench x 2   heavy-duty pole clamp option only 10mm or 13/32 inch wrench  AirSynergy securing flange nuts Large pliers  Tightening cable glands - To fit 15mm Knife  For stripping insulation Wire cutters  Wire strippers Cutting of  insulation Ring terminal crimp tool  Tilt-meter  If accurate down-tilt of antenna needs to be set 4.2.2  Verify the Parts and Kits Table 8 - AirSynergy installation parts and kits Installation Kit / Part Part No. Consisting of Note: Main AirSynergy parts SYN-U-PMK-2 1 x AirSynergy Universal Mounting Plate and pole strap kit Includes 2 pole straps for poles up to 200mm diameter (minimum pole diameter 50mm) SYN35-xx-xx-xxx-xxx AirSynergy unit(s) Frequency band and assembly type-specific  Verify order and requirements to ensure the correct unit type is being installed. Optional Accessories
 AirSynergy 2000 Installation Guide     Page 25  Commercial in Confidence  UGD-D01001 Rev B Installation Kit / Part Part No. Consisting of Note: SYN-SUN-KT-1 1 x Sun Shield (Spare Unit) Sun shield with included hardware (6 Flathead screws) SYN-SEC-MKT-1 1 x Sector Antenna mounting plate with fixing kit 4 M4 nuts 4 M4 flat washers 4 M4 spring washers 4 Cable ties 4 M5 SEM  SEC60D-x.x-SYN-RC-x 1 x Sector Antenna (front mount)   GPS-SYN-KIT GPS Antenna kit Bracket M6 screw M6 plain washer M6 spring washer TNC to TNC cable (25cm) Connecting cables  Grounding cable  M6 Lug at each end  Power Supply and power cable SYN-PSU-OD-AC-3 Optional AC/DC 150W PSU module 1 per AirSynergy unit PWR-xx-INST-2 DC Power cable 1 per AirSynergy unit  with external grade power cable with compatible power weather-proof connector (variable lengths) SYN-PWR-JOIN-1 Cable Join kit 1 per AirSynergy unit  SYN-PSU-ODUL-AC-3 Optional AC/DC 150W PSU in weatherproof enclosure (NEMA approved) Alternative to the standard 48V PSU (required for all North American  installations)
 AirSynergy 2000 Installation Guide     Page 26  Commercial in Confidence  UGD-D01001 Rev B Table 9 - External Antenna and feeder kits (Optional) Installation Kit / Part Note External Antenna Several variants - Verify the correct unit type is being installed. Typically a 2 port dual-slant cross-polar antenna  Pole mounting kits (supplied with antenna) Antenna RF Cable  Variable length Heliax RF cables (for mounting antenna on the same pole immediately behind the AirSynergy unit or where the Antenna needs to be mounted away from the AirSynergy unit)  Table 10 - AirSynergy additional items Additional Common Accessories  (not provided by Airspan) CAT-5e RJ45 network cable Cable ties Self-amalgamating tape Black PVC tape Ring terminal for ground cable. M6 Ground cable (4-6 mm) (yellow and green cable) 4.2.2.1 Power Supply AirSynergy supports direct connection to DC power source (-48V DC):   Operational Voltage Range: -40.5 to -57 VDC   Transient Voltage: +150V (ETR283). 4.2.3  Verify Components The following figures display various AirSynergy components and accessory kits.   Note: AirSynergy variants with Sunshield, front mounted antenna and Switched Beam antenna come factory pre-assembled.  Table 11 - AirSynergy components Parts Images AirSynergy Unit (with Sunshield) in typical packing box
 AirSynergy 2000 Installation Guide     Page 27  Commercial in Confidence  UGD-D01001 Rev B Parts Images AirSynergy Unit (with front mounted antenna) in typical packing box  AirSynergy unit with Switched Beam antenna and sunshield (factory assembled)  Universal mounting plate and pole straps  PSU AC/DC (switching power supply unit)  Enclosed PSU (U.S. requirement)
 AirSynergy 2000 Installation Guide     Page 28  Commercial in Confidence  UGD-D01001 Rev B Parts Images GPS antenna mounting kit (boxed)   AirSynergy is shown below from the Ethernet termination and RF port end views respectively.  Figure 6 - AirSynergy Unit, bottom termination   Figure 7 - AirSynergy Unit, RF ports, Internal Duplexers
 AirSynergy 2000 Installation Guide     Page 29  Commercial in Confidence  UGD-D01001 Rev B  Figure 8 - AirSynergy Unit, RF ports   Figure 9 - AirSynergy Unit, RF ports, External Duplexers 4.2.4  Physical Dimensions AirSynergy is in an all outdoor enclosure. Table 12 - AirSynergy physical dimensions Parameter Value Comment Height 530 mm (20.9 in)  The physical dimensions exclude antenna and connectors Width 144 mm (4.49 in) Depth 106 mm (4.17 in) Weight  Main unit (Connectorized) 4.65 kg (10.25 lb) Universal mounting bracket (Including pole straps) 925 g (2.04 lb) Sun-shield 575 g (1.27 lb) Front mount antenna & plate 1.35 kg (2.98 lb)  RF Ports for antenna connections are N-Type Female connectors located on the top of the AirSynergy enclosure.
 AirSynergy 2000 Installation Guide     Page 30  Commercial in Confidence  UGD-D01001 Rev B 4.2.5  Environmental   Note: AirSynergy is not meant to be used in a Marine environment.  AirSynergy meets the following environmental requirements:   ETSI EN 300-019-1-4 Operational (non-weather protected equipment)   ETSI EN 300-019-1-1 Storage (weather protected, not temperature controlled locations)   ETSI EN 300-019-1-2 Transportation  Table 13 - AirSynergy Environment Compliance Type Details Standard Compliance Operating temperature -40°C to 55°C ETSI 300 019 1-4 Operating humidity 5% - 100% non-condensing ETSI 300 019 1-4 Storage temperature -40°C to 70°C N/A Storage humidity 5% - 100% non-condensing ETSI 300 019 1-4 Rain and dust ingress protection IP66 N/A Operational altitude 70-106 kPa as well as: From -60m to 1800m @ 40C From 1800m to 4000m @ 30C ETSI 300 019 1-4 Solar radiation 1120 W/m2 ETSI 300 019 1-4
 AirSynergy 2000 Installation Guide     Page 31  Commercial in Confidence  UGD-D01001 Rev B 5  Install AirSynergy Install the AirSynergy eNodeB by pole mount, wall mount, or single point.  The AirSynergy unit can be connected to various types of antennas via standard RF coaxial cables.  Antennas should be positioned with 10 wavelengths horizontal separation to give optimal Downlink and Uplink MIMO performance. AirSynergy is normally mounted on a pole (in close proximity to its external antenna when not using the AirSynergy front mounted Antenna). Take care to install the mounting plate the correct way up. This is with the slot openings in the bracket at the top edges as shown.  Caution: Proper local rigging and hoisting practices should be followed when installing the AirSynergy.  5.1 Pole Mount Assembly The following images show the pole mount assembly. 1.  Position mounting plate with slots facing up.  Figure 10 - AirSynergy mounting plate and hardware 2.  Feed clamp bands through the quick release locking mechanisms and wrap around pole.   Figure 11 - Assemble clamp bands (2 required)  3.  Wrap the band to properly fit on the pole. Press down locking mechanism with band excess fed through the mechanism.
 AirSynergy 2000 Installation Guide     Page 32  Commercial in Confidence  UGD-D01001 Rev B  Figure 12 – press down locking mechanism 4.  Align and position each of the 2 pole clamps. Tighten the clamp bands with large flat screwdriver in place.  Figure 13 – tighten clamp bands 5.  Mounting plate is installed and ready for AirSynergy mounting.  Figure 14 – mounting plate installed on large diameter pole 5.2  Wall Mount Assembly The following images show the wall mount assembly. 1.  Position mounting plate against the wall with slots facing up. Be sure to position the wall mounting plate straight with level mounting to ensure the unit sits evenly.
 AirSynergy 2000 Installation Guide     Page 33  Commercial in Confidence  UGD-D01001 Rev B  Figure 15 - positioning wall mounting plate 2.  Mark the wall through the holes on the wall mount at the required height. 3.  Attach the mounting plate to the wall using wall plugs (x4) rated for at least 8-10 Kg per fastener.  Figure 16 - wall mounting plate fastened on wall    Note: Wall plugs (x4) and necessary hardware are not supplied by Airspan and are the responsibility of the installer. Recommended minimum 8mm dia. with appropriate wall plugs according to field conditions. 5.3 Front Sector Antenna Assembly   Note: The following section is included for spare-parts or replacement assembly instructions as front mounted antenna variants come factory pre-assembled.  The AirSynergy unit can be used either with a sector antenna mounted directly on the front or with a remotely attached antenna. The following describes the installation procedure for the front mounted antenna. For installation of a remotely mounted antenna follow the antenna manufacturer’s instructions and connect the antenna to the AirSynergy using the appropriate cables. (Weather-proofed N-type Heliax RF cables (ordered separately).
 AirSynergy 2000 Installation Guide     Page 34  Commercial in Confidence  UGD-D01001 Rev B   Note: When a front mounted antenna is not attached to the unit (remote antenna) a Sun-shield should be attached. Variants utilizing remotely attached antennas come factory pre-assembled with a sunshield.  To mount the front antenna, perform the following: 1.  Fit the antenna to the (antenna) mounting plate. The four (4) studs on the back of the antenna pass through the front face of the mounting plate and are secured with the 4 sets of M4 nuts and washers (flat and split) included in the kit. Carefully position the lead RF cables as shown in the figure below and secure them in place to the eyelets on the back of the mounting plate with the provided cable ties. The cables are formed with a cross-over at the bottom.   Note: It is recommended to place some packing material under the unit while assembling to protect it from scratches.   Figure 17 - attaching front mounted antenna to mounting plate 2.  Attach the assembled front mounted antenna with the bracket to the AirSynergy unit using the M5 SEMs (2 on each side) and connect the RF cables to the N type RF ports on the top of the AirSynergy.   Note: The plate is mounted with the side slots towards the top so that the required tilt-down can be set.   Figure 18 – Attaching front mount antenna assembly to AirSynergy 5.4 Connecting GPS Antenna to AirSynergy The GPS antenna should be installed far from:   High-voltage power cables.   Strong radiation area of any TV transmission stations.   Radiation area of the main lobe of the RF Antenna.   Radiation area of the microwave antenna.   Other areas with inter-frequency interference or strong electromagnetic interference. Cable Fastening Good Practices:   No more than 5m between cable fastening spaces.   No more than 1m between cable termination and first fastener.   Fastenings should be to a robust construction (i.e. mast pole, unit mount…).
 AirSynergy 2000 Installation Guide     Page 35  Commercial in Confidence  UGD-D01001 Rev B   Fasteners should be weather and UV resistant.   Cables should have some slack for thermal expansion/contraction between fastenings. An 80cm cable (supplied with GPS antenna kit) connects the GPS directly to the AirSynergy connecter, on the bottom panel. When mounting the GPS antenna remotely from the unit, the GPS antenna should be used in conjunction with the Remote GPS Antenna Mounting Bracket (supplied with the GPS antenna kit) and the appropriate length GPS cable RG58 TNC-TNC by way of TNC connectors.  Note: All cables should be properly secured to prevent undue strain on any of the cable terminations.     Note: AirSynergy units without a factory assembled Switched Beam Antenna all require a GPS antenna (unless an alternative synchronization method is used, such as IEEE1588-2008) which comes in a kit with a mounting bracket and a 80cm cable. A primary consideration for a GPS antenna is a clear view of the sky, preferably 360 degrees.  1.  Assemble the GPS antenna to the mounting bracket supplied in the GPS antenna mounting kit. The large nut should be tightened with a pipe wrench.   Caution: Take care not to over tighten the nut so as not to damage the plastic threads.    Figure 19 - attaching GPS antenna to mounting bracket 2.  Attach the TNC to TNC cable from the GPS antenna to the TNC connecter on the bottom of the AirSynergy unit.   Note: For extreme weather conditions weather-proofing of the TNC connections is recommended. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weather-proofing is best done at this stage to give easier access to the connections.  3.  Attach the GPS antenna assembly to the body of the AirSynergy unit using the single M6 screw and lock washer provided in the kit. There is a threaded hole on the top corner of the AirSynergy unit for this purpose.
 AirSynergy 2000 Installation Guide     Page 36  Commercial in Confidence  UGD-D01001 Rev B  Figure 20 - Attaching the GPS antenna assembly to AirSynergy  Caution: Attach the GPS bracket in the displayed position only, so as not to restrict the airflow in any way. 5.5  Securing AirSynergy to the Mounting Plate  Note: the following procedure can also be performed with the Front-Mount antenna variants exactly as shown below.  To mount AirSynergy to the universal mounting plate, perform the following: 1.  Loosely fit the flange nuts on the studs protruding from the sides of the unit.    Figure 21 - Lift unit to top of mounting plate 2.  Hook the studs into the top slots of the mounting plate.   Figure 22 - unit engages into slots on the top of mounting plate 3.  With the studs engaged in the top slots raise the unit slightly until the bottom studs also drop into their respective slots.
 AirSynergy 2000 Installation Guide     Page 37  Commercial in Confidence  UGD-D01001 Rev B  Figure 23 - lift the unit until the bottom studs fit into the bottom slots   Figure 24 - AirSynergy unit engaged into the bottom slots 4.  Tighten the flange nuts (4 places) to the required degree of down-tilt. 5.  Check and tighten all flange nuts. 5.6  Front Mount Antenna Tilt Adjustment After assembly it is possible to adjust the front mounted antenna tilt-down. There are adjustment slots located on the sides of unit body and on the sides of the front mounted antenna mounting plate.    Note: Combined tilt adjustment of both the unit body and the antenna yield a maximum downtilt of 8°  1.  Slightly loosen the upper flange nuts (2) where the unit is fixed to the wall/pole mounting bracket.   Figure 25 - tilt adjustment body 2.  Slightly loosen the upper screws (2) where the front mount antenna is fixed to the unit.
 AirSynergy 2000 Installation Guide     Page 38  Commercial in Confidence  UGD-D01001 Rev B  Figure 26 - tilt adjustment antenna 3.  After adjusting to the required tilt amount tighten both flange nuts and both screws. 5.7   LED Display A single tri-color LED (Green/Red/Orange) appears at the bottom of the unit, providing unit status indication. When powering up refer to the following table for indication of current status: Table 14 - LED Display Name Color Status Description Powering Up Orange On Continuously Till the SW starts loading Software loading Green Blinking (3Hz) While SW is loading Normal Operation Green On Continuously Normal operation (no alarm) Major Alarm Red Blinking (3Hz) Service not affected Critical Alarm or Sector OOS Red On Continuously
 AirSynergy 2000 Installation Guide     Page 39  Commercial in Confidence  UGD-D01001 Rev B 6  Connect and Manage Cables 6.1 Connecting the Ground Cable There is an option to connect a ground cable to the M6 screw threaded connection at the bottom of the main body casting. This should be connected to a protection ground bar or clamped directly to the steel structure of the power or pole. This is required in areas of high lightning activity or when the AirSynergy unit is mounted on high exposed roofs or tower structures. A direct earth ground connection is required for the surge protection devices inside the AirSynergy to be effective. 1.  Remove grounding screw and slip the ring terminal end of the ground cable onto the screw prior to re-setting into the threaded hole.   Figure 27 – attaching ground cable to AirSynergy  2.  Connect the ground cable to the to the protection ground bar using a suitable crimp lugs.  Alternatively use a clamp to bond the ground cable to the mounting pole or to the tower structure.  Figure 28 - attach ground cable to pole   Note: When installing a protection ground take care to use suitable metal combinations to avoid or minimize galvanic corrosion.
 AirSynergy 2000 Installation Guide     Page 40  Commercial in Confidence  UGD-D01001 Rev B 6.2 Connecting RF Jumper Cables to External Antenna 1.  Attach, connect and secure the RF cable between the external antenna and the appropriate RF connection on the top of the unit.  Figure 29 - Connecting RF cable   Caution:  Do not over-tighten the RF connector. RF failures can result when the RF connector is over-tightened.   Figure 30 - weather-proof the connection - external antenna 2.  Weather-proofing of the RF N type connections is recommended. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. 3.  Verify the RF connector is completely weather-sealed. 6.3 Connecting the DC Power Cable to AirSynergy 1.  Plan the position of the DC power cable run from the AirSynergy unit to the power supply unit. The DC power cable is offered in various lengths, to fit different deployments. 2.  Uncoil the cable and secure the connector just below the AirSynergy unit.    Note: When securing the cable make sure there is no tension on the connector so that it is easy to disconnect and re-connect for future maintenance actions.  3.  Position the pins correctly, the connector is secured to the unit with a locking ring that is screwed into place. Use firm hand pressure only, the connector has a built in sealing ring.   Caution:  The internal plastic parts of the mating connector are keyed. Take care to align these by visual inspection or by gently rotating the connector body until the key way sections align and the pins go in before tightening the locking ring.
 AirSynergy 2000 Installation Guide     Page 41  Commercial in Confidence  UGD-D01001 Rev B  Figure 31 - attaching power cable to AirSynergy
 AirSynergy 2000 Installation Guide     Page 42  Commercial in Confidence  UGD-D01001 Rev B 7  Power System Connection  Hazardous voltage!  Before working, ensure that the power is removed from the power connection cables.  When the system is powered on, do not touch the power terminals. 7.1  Required Tools The tools required for the connection of the PSU are:    knife   small flat blade screw driver (electrical insulated shaft recommended)   medium Philips head screwdriver   pliers   small side cutters   tweezers (or fine blade long nose pliers)   Figure 32 - required tools 7.2  Cable Connections 7.2.1   DC Power Cable Installation  When the DC power cable is to be passed through glands and/or down the center of a lamp post or other structure, the DC power cable can be cut leaving sufficient length for ease of termination. With the power supply placed at the selected installation location, trim the cable to the length for proper installation while allowing sufficient length to strip and prepare the cable ends.   Note:  Standard cable supplied is 30m in length, other length options are available.     Note:  Airspan supplies two (2) types of cable, either black wire and white wire cable or black wire and blue wire cable. The cables’ specs are identical only the colors are different.
 AirSynergy 2000 Installation Guide     Page 43  Commercial in Confidence  UGD-D01001 Rev B  Figure 33 - DC Power connection   Figure 34 - Power connection - AirSynergy bottom panel    Advice:  It is good practice to label both ends of the cable to identify which AirSynergy unit it is connected to. This is especially important where numerous AirSynergy units are installed on the same pole/tower.     Advice:  It is good practice to leave a spare loop of cable (approximately 0.5m). This will allow for easier wiring to the power supply and will allow the cable to be re-terminated if necessary in the future.  7.2.2  Network Cable Installation For installations that require a network connection a separate cable must be run to the network Ethernet switch. The standard length of pre-made cable is 30m. For other lengths up to a maximum of 100m cables can be made up on site.   Advice:  It is good practice to label both ends of the Network cable to identify which AirSynergy unit it is connected to. This is especially important where numerous AirSynergy units are installed on the same pole/tower.     Advice:  It is good practice to leave a spare loop of network cable (approximately 0.5m). This will allow for easier wiring to the Network switch and will allow the cable to be re-terminated if necessary in the future.
 AirSynergy 2000 Installation Guide     Page 44  Commercial in Confidence  UGD-D01001 Rev B  Figure 35 - power and network cable overview 7.3 Wiring DC Power Cable to the PSU The DC power cable supplied is a standard 30m (98.42 ft) length with the power connector end for the AirSynergy unit pre-fitted. (Longer lengths are available).   Figure 36 - Waterproof connector exploded view 1.  Choose the location PSU and the route of the power cable. Pass the cable through any building walls or cable entry glands and bring the unterminated end to the location of the PSU. 2.  With the DC power cable from the AirSynergy cut to the required length prepare the cable to fit the waterproof power connector.  3.  Strip back and remove the outer sheath to expose the inner blue and black insulated wires to a length of 3cm (1.18 in). Then strip back 6mm (0.24 in) of the inner core insulation.  Figure 37 - power cable preparation  Figure 38 - waterproof connector separated 4.  Thread the prepared cable end through the gland, washer, sealing ring and body of the connector.
 AirSynergy 2000 Installation Guide     Page 45  Commercial in Confidence  UGD-D01001 Rev B  Figure 39 - gland and connector on cable 5.  Secure the prepared ends of the power cable into the head part of the connector (male part with visible pins).   Figure 40 - secure cable to connector 6.  Insert and secure the black wire into position 1and the blue wire into position 2.  Figure 41 – power cable wires assembled   Note: Individual connection numbers are marked on each part of the connector.    Figure 42 - numbered connector contacts 7.  Assemble the parts of the connector and tighten the gland to provide a waterproof seal.  Figure 43 - assemble and tighten 8. Prepare the ends of the PSU low voltage cable and thread the connector parts over the cable. 9.  Secure the prepared ends of the drop cable into the head part of the connector (female part).
 AirSynergy 2000 Installation Guide     Page 46  Commercial in Confidence  UGD-D01001 Rev B Figure 44 - PSU cable connector assembly 10.  Insert and secure the red wire into position 1 and the black wire into position 2  Figure 45 - PSU wires assembled   11.  Assemble the parts of the connector and tighten the gland to provide a waterproof seal.  Figure 46 - assemble and tighten 12.  Fasten the 2 parts of the connector together and tighten to make a watertight seal.  Figure 47 - connector assembled and tightened 7.4 Connecting the AC/DC PSU to Power Supply The power (mains) connection should be connected to a fused or protected mains supply (100 to 240 Volts AC). The Brown wire is the Live, the Blue wire is the Neutral and the Green/Yellow wire is the ground wire.  Figure 48 - High power (240W) PSU – used for dual AirSynergy installations   Figure 49 - Standard power (150W) PSU – used for standard AirSynergy installation  The PSU module can be screwed into position using the self-tapping screws provided (4 places).
 AirSynergy 2000 Installation Guide     Page 47  Commercial in Confidence  UGD-D01001 Rev B  Figure 50 - attaching PSU    Note: For USA deployments an alternative PSU and enclosure arrangement is required – Refer to Appendix D.        Figure 51 - PSU for USA deployment   Caution: Safety - Disconnection of AC supply.   When AirSynergy is connected directly to building or lamp post wiring a suitably rated and easily accessible disconnect device shall be incorporated external to the equipment.    When AirSynergy is connected to the AC power supply using a plug and socket, the socket-outlet shall be installed near the equipment and shall be easily accessible.
 AirSynergy 2000 Installation Guide     Page 48  Commercial in Confidence  UGD-D01001 Rev B 8  Appendix A Review Job Sheet The Job Sheet should include the following information:   Pole for installation identified   Position on pole identified   Pole access restrictions (highway regulations, other services on pole, power pole)   Method of reaching pole positions (ladders, Elevated work platform)   AC main fuse block available for PSU (where needed)   Configuration programming details known   Point of connection for Ethernet (if applicable)   All equipment items available at the installation site o  Main AirSynergy unit o  Mounting bracket and pole clamps o PSU o  Ethernet cable assembly o  GPS Antenna o  GPS antenna installation kit o  Front sector Antenna (if applicable) o  Front sector Antenna mounting bracket ad fixing kit (if applicable) o  External panel antenna (if applicable) o  RF feeder cable tails (if applicable)   Required tools o  Large flat screw driver for pole clamps o  Small flat blade screw driver (insulated shaft recommended) o  Medium Philips head screw driver o  13mm wrench or small pipe wrench o  10mm wrench for unit mounting flange nuts o  Knife o  pliers o  Small side cutters o  Tweezers (or fine blade long nose pliers) o  Wire strippers o  Ring terminal crimping tool o  Tilt-meter   Required ancillary equipment o Laptop PC for initial configuration o  Ethernet cable for temporary connection of the lap top   Other install materials o  Self-amalgamating tape o  Black PVC tape o  Cable ties   Labels   Whether the system is required to be locked to a GPS timing reference..
 AirSynergy 2000 Installation Guide     Page 49  Commercial in Confidence  UGD-D01001 Rev B 9  Appendix B - Glossary of Terms - Acronym, Abbreviations & Definitions Table 15 - Glossary of Terms Term Definition  3GPP 3rd Generation Partnership Project, responsible for LTE AWGN Additive White Gaussian Noise is a channel model in which the only impairment to communication is a linear addition of white noise with a constant spectral density and a Gaussian distribution of amplitude. BER Bit Error Rate dB Decibel. A logarithmic unit used to describe a ratio (such as power ratio in radio telecommunications) dBm An abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). It is used as a convenient measure of absolute power because of its capability to express both very large and very small values in a short form eNodeB Evolved Node B, is the element in E-UTRAN of LTE ESP Encapsulating Security Payloads (ESP) provide confidentiality, data-origin authentication, connectionless integrity, an anti-replay service (a form of partial sequence integrity), and limited traffic-flow confidentiality E-UTRAN Evolved UMTS Terrestrial Radio Access Network, is the air interface of 3GPP's Long Term Evolution FDD Frequency-Division Duplexing. A transceiver mode where the transmitter and receiver operate at different carrier frequencies GNSS Global Navigation Satellite System is a term used to describe a satellite navigation system with global coverage. There are currently two fully operational GNSSs – the US GPS and the Russian GLONASS. HPBW Half Power BandWidth is the angular separation in an antenna, in which the magnitude of the radiation pattern decreases by 50% (or -3 dB) from the peak of the main beam IPSec Internet Protocol Security is a protocol suite for securing Internet Protocol (IP) communications by authenticating and encrypting each IP packet of a communication session LED Light Emitting Diode LTE Long Term Evolution MAC Medium Access Controller – responsible for several functions such Error Correction, Packet (De)Multiplexing, etc… MME Mobility Management Entity is the key control-node for the LTE access-network. It is responsible, among other things for idle mode UE tracking and paging procedure including retransmissions MTBF Mean Time Between Failures OFDMA Orthogonal Frequency-Division Multiple Access (OFDMA) is a multi-user version of OFDM digital modulation scheme, used for eNodeB transmissions to UEs PDU Protocol Data Unit PTP Precision Time Protocol is used to synchronize clocks throughout a network. In
 AirSynergy 2000 Installation Guide     Page 50  Commercial in Confidence  UGD-D01001 Rev B Term Definition  this document, PTP is referring to IEEE1588-2008 protocol ROHS Restriction Of Hazardous Substances S-GW Serving Gateway. A Core entity in the LTE EPC architecture responsible for routing and forwarding user data packets, while also acting as the mobility anchor for the user plane during inter-eNodeB handovers and as the anchor for mobility between LTE and other 3GPP technologies SBA Switched Beam Antenna SC-FDMA Single-Carrier FDMA is a frequency-division multiple access scheme, dealing with the assignment of multiple users to a shared communication resource. Used in LTE for UE transmissions to the eNodeB SDR Software Defined Radio TDD Time-Division Duplexing. A transceiver mode where the transmitter and receiver operate on the same carrier frequency UE User Equipment. The end user in LTE WEEE Waste Electrical and Electronic Equipment
 AirSynergy 2000 Installation Guide     Page 51  Commercial in Confidence  UGD-D01001 Rev B 10  Appendix C - Installation Checklist The Checklist below gives the high-level steps in the Workflow for this procedure. Detach or print this page to use as a job-aid for completing the actions this procedure requires. Table 16 - Checklist for Procedure Procedure Actions Outcome   1.  Verify Prerequisites Verify site requirements Verify safety requirements Verify installation requirements Verify the tools Verify parts and kits All requirements are in place for a successful installation 2.  Install AirSynergy universal mounting  plate  Install the universal mounting plate  3.  Install AirSynergy on the mounting plate   4.  Connect and manage cables Connect power cable Connect GPS cable  5.  Connect power system Connect Power Connect the ground cable Connect to Ethernet backhaul
 AirSynergy 2000 Installation Guide     Page 52  Commercial in Confidence  UGD-D01001 Rev B 11  Appendix D – PSU for USA To comply with US regulations that apply to outdoor deployments of mains power supplies, a special US version of the AirSynergy power supply has been produced with the PSU module and the electrical connecting blocks enclosed in a small NEMA approved enclosure. The electrical power cable and 48V power cables are brought through the weatherproof glands provided. This type of power supply (SYN-PSU-ODUL-AC-3) must  be used for all deployments in the USA.  Figure 52 - PSU for USA 1.  Remove the top cover of the PSU enclosure.   Figure 53 - Inside PSU with cable terminations 2.  Feed the DC power cable through the gland nearest to the low voltage connection and connect to the terminal strip, observing the correct polarity. (Blue wire in drop cable to negative terminal and Black wire in the drop cable to positive) 3.  Isolate the power supply and pass the power cable through the input gland and terminate on the connection blocks provided. The termination blocks are clearly labeled as  Live, Neutral and Earth. 4.  Choose a suitable position for the PSU enclosure. The PSU enclosure should be screwed to a firm surface with screws in 4 positions which are only accessible with the top cover removed. 5.  Once the enclosure top cover has been re-fitted (4 screw positions) and the wiring completed the power can be connected.
 AirSynergy 2000 Installation Guide     Page 53  Commercial in Confidence  UGD-D01001 Rev B 12  Appendix E 12.1 Revision History Revision Originator Date Description Rev A M. Falik 09-2013 Initial document Rev A1 M. Falik 09-2013 “warning” correction Rev A2 M. Falik 03-2014 TX Power table update Rev A3 + 4 M. Falik 04-2014 UpdatesCable update + 2K name Rev A5 M. Falik 05-2014 updates Rev B + B1 M. Falik 06-2014 Antenna tilt – Max TX update 12.2 Contact Information Customer Service Help-Desk for customer service emergency Airspan Networks have introduced the Airspan Tracker application to enable prompt and efficient Customer Support services. If you do not have an Airspan Tracker account, please obtain login credentials by filling-in the form in the main page www.airspan.com/Support Register New Account  Worldwide Headquarters: Airspan Networks Inc. 777, Yamato Road, Suite 310, Boca Raton, FL 33431, USA Tel: +1 561 893 8670  93Hwww.airspan.com  Feedback: To provide feedback on this document, please send comments to the following email address: 94Hdocumentfeedback@airspan.com