Alarm Controls 1200S CUTSHEET Installation Instructions

User Manual: Alarm Controls 1200S Installation Instructions Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadAlarm Controls 1200S CUTSHEET Installation Instructions
Open PDF In BrowserView PDF
MAGNETIC LOCK INSTALLATION INSTRUCTIONS
PLEASE READ BEFORE INSTALLATION
ALARM CONTROLS CORPORATION OFFERS A COMPLETE LINE OF MAGNETIC LOCKS AND ACCESSORY ITEMS
TO ASSIST THE INSTALLER IN MANAGING EVERY APPLICATION.
THE MAGNETIC LOCK IS DESIGNED TO MOUNT TO THE DOOR FRAME ON THE STOP SIDE OF THE DOOR IN A
TYPICAL OUTSWINGING DOOR INSTALLATION,(SEE PAGE 2 FOR INSWINGING DOOR INSTALLATION).
SUFFICIENT HEADER SPACE MUST BE AVAILABLE TO MOUNT THE MAGNETIC LOCK TO INSURE A SAFE AND
SECURE INSTALLATION.
1. NOTE TYPE OF DOOR FRAME HEADER AND INSTALL FILLER PLATE OR ANGLE BRACKET AS REQUIRED TO
PROVIDE A FLAT MOUNTING SURFACE ON THE DOOR HEADER THE ENTIRE LENGTH OF THE MAGNETIC LOCK.

OUTSWINGING DOOR INSTALLATION
HEADER
PLATE
HEADER

HEADER

OUT
SWINGING
DOOR

MAGNET
ARMATURE
PLATE

OUT
SWINGING
DOOR

FILLER
PLATE

MAGNET
ARMATURE
PLATE

ANGLE
BRACKET

HEADER

OUT
SWINGING
DOOR

MAGNET
ARMATURE
PLATE

2. FOLD TEMPLATE ON DOTTED LINE TO FORM A 90 DEGREE ANGLE. TAPE TEMPLATE AGAINST DOOR HEADER
WITH DOOR IN A CLOSED POSITION 1” FROM DOOR FRAME OPPOSITE HINGE SIDE OF DOOR JAMB.
FOR A PAIR OF DOUBLE DOORS PLACE TEMPLATE AT THE CENTER OF THE DOOR OPENING.
TRANSFER HOLE LOCATIONS TO DOOR AND FRAME HEADER, (SEE TEMPLATE INSTRUCTIONS).
3. FOLLOW TEMPLATE INSTRUCTIONS FOR HOLE SIZES. USE THE ILLUSTRATIONS BELOW TO DETERMINE THE
PROPER HOLE PREPARATION FOR THE ARMATURE PLATE ACCCORDING TO THE DOOR TYPE IN THE
INSTALLATION.
THE INCLUDED HARDWARE PACKAGE CONTAINS ALL NECESSARY ITEMS TO COMPLETE THE INSTALLATION.

TO REMOVE THE HEADER PLATE INSERT HEX KEY INTO HOLES LOCATED AT
THE BOTTOM OF LOCK ON THE RIGHT AND LEFT SIDE AND UN-SCREW THE CAP SCREWS

SOLID DOOR
STEP 2

FOLLOW WITH
1/2” DIA. HOLE
THRU DOOR

HOLLOW DOOR
STEP 1

DRILL 1/4” DIA.
HOLE THRU
ARMATURE
SIDE OF DOOR

STEP 2

STEP 1

DRILL 1/2” DIA.
HOLE THRU SEX
BOLT SIDE
OF DOOR

DRILL 21/32” DIA.
HOLE THRU
ARMATURE
SIDE OF DOOR

ONE THICKNESS
ONLY

ONE THICKNESS
ONLY

ARMATURE
PLATE MUST
ROCK ON DOOR

ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE
P.O. BOX 280
DEER PARK, NY 11729
800 645-5538 WWW.ALARMCONTROLS.COM

ARMATURE
PLATE MUST
ROCK ON DOOR

INSWINGING DOOR INSTALLATION WITH L- Z BRACKET
STEP 1

DOOR
FRAME

FASTEN THE L BRACKET ON THE DOOR FRAME IN A SUITABLE LOCATION.
MOUNT THE MAGNETIC LOCK TO THE L BRACKET.
MAKE SURE THAT THE MAGNETIC LOCK DOES NOT OBSTRUCT THE
CLOSING OF THE DOOR.
CONNECT THE CORRECT VOLTAGE TO THE MAGNET.

L
BRACKET

ADJUSTABLE
Z BRACKET

STEP 2
ASSEMBLE THE Z BRACKET WITH THE SOCKET HEAD CAP SCREWS
PROVIDED. DO NOT TIGHTEN THE CAP SCREWS AT THIS TIME. THE
Z BRACKET MUST BE ADJUSTABLE.

ARMATURE
BOLT

METAL
WASHERS

STEP 3

MOUNT THE ARMATURE PLATE TO THE ADJUSTABLE SECTION OF THE Z
BRACKET WITH THE ARMATURE BOLT. DO NOT REMOVE THE RUBBER
WASHER ATTACHED TO THE ARMATURE BOLT.
USE ONE RUBBER WASHER BETWEEN TWO METAL WASHERS ON THE
ARMATURE BOLT. THE WASHER ASSEMBLY MUST BE BETWEEN THE
ARMATURE PLATE AND THE ADJUSTABLE SECTION OF THE Z BRACKET.
APPLY THE SCREW LOCKING AGENT TO THE ARMATURE BOLT.

RUBBER
WASHER

DO NOT OVER TIGHTEN. ARMATURE MUST ROCK TO ALIGN WITH THE MAGNET.

ADJUSTABLE
SECTION OF
Z BRACKET WITH
ARMATURE PLATE
ATTACHED

STEP 4

CLOSE THE DOOR AND ALIGN THE ARMATURE PLATE TO THE MAGNET
AND APPLY POWER TO THE MAGNET. LET THE ARMATURE PLATE BOND
TO THE MAGNET. BE SURE THE Z BRACKET ASSEMBLY IS FIRMLY

AGAINST THE CLOSED DOOR.
Z BRACKET
ARMATURE
ASSEMBLY

COMPLETED
INSWINGING DOOR
INSTALLATION

TIGHTEN THE CAP SCREWS HOLDING THE Z BRACKET ARMATURE PLATE
ASSEMBLY.
FASTEN THE Z BRACKET ASSEMBLY TO THE DOOR WITH THE SCREWS SUPPLIED.

STEP 5

CHECK THE COMPLETED ALIGNMENT AND INSTALLATION OF THE
MAGNET AND ARMATURE PLATE BY OPENING AND CLOSING THE DOOR
BY ENERGIZING AND DE-ENERGIZING THE MAGNETIC LOCK SEVERAL
TIMES.
THIS WILL INSURE THAT THE CORRECT OPERATION AND ALIGNMENT
OF THE MAGNETIC LOCK HAS BEEN PROPERLY INSTALLED.

MAGNETIC LOCK L / Z BRACKETS FOR INSWINGING DOORS
AM2370 FOR 300 POUND MAGNETIC LOCK
AM3370 FOR ALL 600 POUND MODELS OF SINGLE MAGNETIC LOCKS
AM6370 FOR ALL 1200 POUND MODELS OF SINGLE MAGNETIC LOCKS
AM3375 FOR ALL 600 POUND MODELS OF DOUBLE MAGNETIC LOCKS
AM6375 FOR ALL 1200 POUND MODELS OF DOUBLE MAGNETIC LOCKS

MAGNETIC LOCK CARE AND MAINTENANCE
MAGNETIC LOCKS HAVE NO INTERNAL MOVING PARTS AND REQUIRE A MINIMUM AMOUNT OF MAINTENANCE.
IT IS RECOMMENDED THAT THE FACE OF THE ARMATURE PLATE AND MAGNET BE WIPED CLEAN AND A L IGHT
COATING OF A SUITABLE SILCONE LUBRICANT BE APPLIED TO EACH SURFACE TO PREVENT RUST ALTHOUGH
THE MATING SURFACES HAVE BEEN PLATED. THIS ONLY NEEDS TO BE DONE WHEN DIRT BUILD-UP IS NOTICED.
THE ARMATURE PLATE BOLT AND THE HEX HEAD SCREWS HOLDING THE MAGNET TO HEADER PLATE SHOULD
BE CHECKED EVERY THREE MONTHS TO INSURE A SAFE AND SECURE INSTALLATION.

MAGNETIC LOCK ELECTRICAL SPECIFICATIONS
300 POUND MODEL SINGLE MAGNETIC LOCK, 250 MA. @ 12 VDC, 130 MA. @ 24 VDC
ALL 600 POUND MODELS OF SINGLE MAGNETIC LOCK, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC
ALL 1200 POUND MODELS OF SINGLE MAGNETIC LOCK, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC
ALL 600 POUND MODELS OF DOUBLE MAGNETIC LOCKS, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC, EACH LOCK
ALL 1200 POUND MODELS OF DOUBLE MAGNETIC LOCKS, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC, EACH LOCK
ALL MAGNETIC LOCKS ARE SET AT THE FACTORY FOR 24 VDC

TYPICAL MAGNETIC LOCK WIRING

PIR

POSITIVE
FILTERED
DC
POWER
SUPPLY

NEGATIVE

N/C
REX
BUTTON

DIGITAL
KEYPAD

+

-

MAGNETIC
LOCK

WIRE GAUGE CHART
DISTANCE FROM POWER SUPPLY TO MAGNETIC LOCK
12 VDC

50
FEET

100
FEET

150
FEET

200
FEET

300
FEET

400
FEET

500
FEET

750
FEET

1000
FEET

24 GA.

22 GA.

22 GA.

22 GA.

20 GA.

18 GA.

18 GA.

16 GA.

14 GA.

24 GA.

24 GA.

24 GA.

22 GA.

22 GA.

22 GA.

20 GA.

20 GA.

18 GA.

24 GA.

22 GA.

22 GA.

20 GA.

18 GA.

18 GA.

16 GA.

14 GA.

14 GA.

24 GA.

24 GA.

22 GA.

22 GA.

22 GA.

20 GA.

20 GA.

18 GA.

16 GA.

22 GA.

22 GA.

20 GA.

18 GA.

18 GA.

16 GA.

14 GA.

14 GA.

12 GA.

24 GA.

22 GA.

22 GA.

22 GA.

20 GA.

18 GA.

18 GA.

16 GA.

14 GA.

22 GA.

20 GA.

18 GA.

18 GA.

16 GA.

14 GA.

14 GA.

12 GA.

10 GA.

24 GA.

22 GA.

22 GA.

20 GA.

18 GA.

18 GA.

16 GA.

14 GA.

14 GA.

22 GA.

18 GA.

18 GA.

16 GA.

14 GA.

12 GA.

10 GA.

10 GA.

8 GA.

22 GA.

22 GA.

20 GA.

18 GA.

18 GA.

16 GA.

14 GA.

14 GA.

12 GA.

20 GA.

18 GA.

16 GA.

14 GA.

14 GA.

12 GA.

10 GA.

10 GA.

8 GA.

22 GA.

20 GA.

20 GA.

18 GA.

16 GA.

14 GA.

14 GA.

12 GA.

10 GA.

24 VDC
200 MA.

D
C
C
U
R
R
E
N
T

300 MA.

400 MA.

600 MA.

800 MA.

1 AMP.

TROUBLE SHOOTING GUIDE
PROBLEM

CAUSE

SOLUTION

LOCK BUZZES

AC VOLTAGE CONNECTED TO LOCK
AC RIPPLE IN POWER SUPPLY

SUPPLY DC VOLTAGE TO LOCK
REPLACE POWER SUPPLY

INCORRECT INPUT VOLTAGE

CHECK VOLTAGE JUMPER POSITION
FOR CORRECT VOLTAGE SETTING
LOCK SET AT FACTORY FOR 24 VDC

LOW INPUT VOLTAGE

CHECK POWER SUPPLY VOLTAGE
WIRE GAUGE INCORRECT FOR WIRE RUN

MISALIGNMENT OF ARMATURE PLATE

ARMATURE PLATE MUST COVER ALL
MAGNETIC POLES OF LOCK

ARMATURE PLATE SCREWED TIGHT
TO DOOR

ARMATURE PLATE MUST ROCK ON
DOOR TO ALIGN WITH LOCK

WRONG HARDWARE ASSEMBLY

A METAL WASHER,RUBBER WASHER AND
METAL WASHER MUST BE BETWEEN
DOOR AND ARMATURE PLATE

NO POWER TO DOOR

CHECK POWER AT LOCK
CHECK POWER SUPPLY
CHECK ALL CONNECTIONS

MAGNET IN ARMATURE PLATE
NOT ALIGNED WITH LOCK

ALIGN MAGNET IN ARMATURE PLATE WITH
DOOR STATUS SENSOR DOT ON LOCK

INSUFFICIENT HOLDING FORCE

DOOR DOES NOT LOCK

DOOR STATUS SENSOR NOT WORKING
(APPLICABLE MODELS)

MODEL 1200 SERIES SINGLE DRILL TEMPLATE
1/2” DIA.
WIRE HOLE

HEADER PLATE
ADJUSTMENT
MOUNTING
HOLE

HEADER PLATE
ADJUSTMENT HEADER MOUNTING PLATE
MOUNTING
HOLE

PLACE EDGE OF TEMPLATE

PLACE EDGE OF TEMPLATE
1” FROM DOOR JAMB

1” FROM DOOR JAMB

OPPOSITE HINGES FOR L.H.

OPPOSITE HINGES FOR L.H.

DOOR INSTALLATIONS

DOOR INSTALLATIONS

ARMATURE PLATE

DRILL 1/4” ANTI-ROTATION PIN HOLES 3/4” DEEP

DO NOT DRILL THRU DOOR

STEP 1

LOCATING MOUNTING HOLES

STEP 2

INSTALLING ARMATURE PLATE

A. FOLD TEMPLATE AT DOTTED LINE.
A. DRILL A LEVEL 1/4” DIA. HOLE THRU THE
DOOR. FOLLOW WITH A 1/2” DIA. DRILL.
B. PLACE BOTTOM PORTION OF
TEMPLATE AGAINST THE DOOR.
THIS IS FOR A SOLID DOOR ONLY !
C. LOCATE AND MARK THE THREE HOLES B. DRILL TWO 1/ 4” HOLES FOR THE
ANTI-ROTATION PINS 3/4” DEEP.
ON ARMATURE PLATE.
D. LOCATE AND MARK THE TWO ADJUST- C. MOUNT THE ARMATURE PLATE TO
THE DOOR WITH THE SEX BOLT.
MENT HEADER PLATE HOLES AND
WIRE HOLE ON THE HEADER MOUNT- D. PLACE A METAL WASHER A RUBBER
ING PLATE.
WASHER AND A METAL WASHER ON
BOLT BETWEEN DOOR AND ARMATURE.
E. ARMATURE MUST ROCK ON DOOR.

STEP 3

STEP 4

HEADER MOUNTING PLATE

INSTALLING MAGNET

A. MOUNT HEADER PLATE TO JAMB USING
THE TWO ADJUSTMENT HOLES.
B. RUN THE CONTROL CABLE THRU THE
WIRE HOLE.
C. SLIDE MAGLOCK ON HEADER
MOUNTING PLATE.
D. ADJUST THE POSITION OF MAGLOCK
TO CONTACT THE ARMATURE.
E. REMOVE MAGLOCK AND SECURE
HEADER MOUNTING PLATE WITH THE
SIX REMAINING SCREWS.

A. SLIDE MAGLOCK ON HEADER PLATE.
B. FASTEN MAGLOCK TO HEADER PLATE
WITH THE ALLEN HEAD CAP SCREWS
LOCATED AT EACH END OF THE LOCK.
C. AFTER CHECKING FOR PROPER OPERATION AND ALIGNMENT APPLY THE
SCREW LOCKING AGENT TO HEADER
MOUNTING PLATE SCREWS, ARMATURE
BOLT AND ALLEN CAP SCREWS.

ALARM CONTROLS CORPORATION, DEER PARK, NY 11729

MAGNETIC LOCK WIRING INSTRUCTIONS
MODELS
600S, 600L, 600D, 1200S, 1200L
To remove the header plate, it may be necessary to remove the wiring compartment screw. A long wiring
compartment screw can be used to increase security by limiting access to the header plate mounting
screw from below the lock.

WIRING INSTRUCTIONS
VOLTAGE IS FACTORY SET FOR 24VDC OPERATION. For 12VDC operation, access the voltage
selection switch via the wiring compartment.

600 Series

1200 Series

A terminal block is provided for wiring the maglock to the power supply.
For models 600L and 1200L a pair of flying leads are provided for the LED. Connect the Red Lead to (V+) and
the Black LED to (V-)

ALIGNMENT OF THE MAGLOCK AND ARMATURE PLATE
Align the maglock and armature plate as shown.
Armature plate must be mounted to door using the rubber washer sandwiched between the metal washers
provided. Do not excessively tighten bolt. Armature must float on door. Screw locking agent is provided on
each screw.
MAGLOCK
WIRING
COMPARTMENT

ANTI-ROTATION PINS

ARMATURE PLATE
UNIVERSAL MOUNTING BOLT HOLE
FOR STANDARD OR OFFSET
MOUNTING OF ARMATURE PLATE

MECHANICAL KICK-OFF DEVICE

Alarm Controls Corporation
Deer Park, New York 11729
(800) 645-5538
www.alarmcontrols.com

ASSA ABLOY, the global leader
in door opening solutions
MAGInst7-13



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : HB
Create Date                     : 2015:08:11 11:57:37-07:00
Modify Date                     : 2015:08:11 11:58:05-07:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2015:08:11 11:58:05-07:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : 1200S CUTSHEET:Layout 1.qxd
Creator                         : HB
Document ID                     : uuid:26c2738d-a879-4764-ac51-4d3971bef7f6
Instance ID                     : uuid:e092e04e-993c-4903-9b1b-8051349b2e42
Producer                        : CutePDF 3.6 (www.cutepdf.com)
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Navigation menu