Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST

User Manual: Alarm Lock DL6200, PDL6200 and PDL8200 Installation Instructions Installation Manuals

Open the PDF directly: View PDF PDF.
Page Count: 12

1
Wireless Trilogy®
DL6200, PDL6200 & PDL8200
with Door Monitoring
Installation Instructions
Wireless Trilogy Series
Network Access Control Systems
PDL Series with ProxCard® Access
WI2024B 07/16
PDL6200 with Proximity Card Reader
(The PDL8200 adds 13.56MHz
Smart Card Support)
DL6200
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
or visit us at http://tech.napcosecurity.com/
(Note: Technical Service is for security professionals only)
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2016
2
Wireless Lock Configuration Overview .....................3
Ordering Information ....................................................3
Door Preparation ...........................................................4
Installation Jig ...............................................................4
Latch Installation ...........................................................4
Strike Installation ..........................................................5
Door Contact (Magnet) Installation.............................5
Lock Preparation ...........................................................5
Lock Installation ............................................................5
Adjusting for Door Thickness .....................................6
To Reverse Lever Handing ..........................................6
Install Inside Trim ..........................................................6
Attaching Levers and Locksets ..................................9
Interchangeable (IC) Locks.......................................... 8
Install Interchangeable (IC) Cores .............................. 8
Changing an Existing IC Core ..................................... 9
Removing the IC Core and Lever................................ 9
Programming ...............................................................10
Troubleshooting..........................................................10
Wire Connections .......................................................10
Wiring and Power Up .................................................10
Power Up ......................................................................11
Erase All Programming ..............................................11
Battery Replacement ..................................................11
Warranty .......................................................................12
Note: ProxCard® and ProxKey® are trademarks of the HID© Corporation. Windows is a registered trademark of the Microsoft Corporation. Other products, product
names and services described in this manual are for identification purposes only and may be trademarks of their respective companies.
TABLE OF CONTENTS
3
PDL6200 / DL6200 / 8200 Series
The Trilogy Networx PDL6200, DL6200 and PDL8200 series door
locks are essentially the same as the 6100 series wireless door
locks, but with added Door Monitoring features as follows:
 Entry Logged: A valid credential entered;
 Exit Logged: Inside (protected) lever turned;
 Door Ajar: A valid credential entered and the door
opened but not closed within the programmed time specified;
 Forced Entry: Door opens without a valid credential en-
tered or door opened without the inside lever being turned.
For Door Ajar and Forced Entry, the internal relay can be pro-
grammed to engage, and for Door Ajar an Alert Sounder can be
programmed to sound (Forced Entry always sounds the Alert
Sounder). In addition, the PDL6200, DL6200 and PDL8200 locks
allow you to upload and download programming features wirelessly
using a computer connected to a computer network. With
"wireless" communication, the various cables and/or AL-DTM Data
Transfer Module devices are NOT required to transfer data. You
can use your computer to retrieve logs, download User Codes and
program features into and out of each wireless door lock in your
installation. The 8200 series locks are essentially identical to the
6200 series locks, but are equipped with a 13.56MHz Smart
Card reader.
DL-Windows software is installed on a computer that is connected
to a computer network; connected to this network is an intermedi-
ate device called a Gateway that communicates to a radio located
inside each door lock. In this way, the software allows full program-
ming and control of each lock in the system.
To ensure each physical lock is identi-
fied correctly by DL-Windows, the
factory assigns each lock a unique
serial number; after locks are installed
in the doors and the Gateways are
mounted, the Gateways search for
new locks, allowing them to be en-
rolled into the system.
For every new wireless lock installed on a door, we strongly recom-
mend that you fill out a new yellow-colored "Lock ID Card" (shown
above) with the installation location, lock model and serial number.
These ID cards are a convenient way to keep track of and ensure
all locks are enrolled in the DL-Windows Account.
Flexible Setup
In addition to wireless communication, these wireless door locks
can also be programmed at the keypad. This means that locks can
be installed on the doors and immediately be put into use via key-
pad programming--even before a wireless network is set up.
Therefore, you can install the locks on the doors before configuring
the wireless network, or you can set up the wireless network first
and add locks later. If you wish, you can even start by designing a
"virtual" system within DL-Windows (creating new Accounts, adding
Users and configuring lock features, etc.), then set up the network
and install the lock hardware later. But in the end, after your lock
hardware is physically installed and the network is up and running,
you can run DL-Windows to link the "virtual" system saved on your
computer with the "real" lock hardware on the doors.
Note: Keypad programming of User Codes, Features, Time
Zones, and Schedules is available as a temporary convenience to
allow the lock to be put into use before installing and configuring a
wireless network. Therefore, all lock programming added via the
keypad cannot be retrieved into DL-Windows. If you decide to start
programming your wireless lock via the keypad, we recommend
you keep hardcopy records (in a secure location) of all Users, their
User Codes, and any proximity cards that may have been pro-
grammed. Keeping complete and accurate records saves time
because after the wireless network is set up, any programming
added via the keypad must be re-added to DL-Windows and down-
loaded back to the lock(s).
Ordering Information
PDL6200/26D - Cylindrical Trilogy® Networx Wireless Access
Control Lock with built in HID Proximity ID Card Reader, full-
metal digital keypad, integral bi-directional radio, 4 C-cell battery
-operated (batteries supplied), serial number ID card, standard
format SCI keyway for manual key override, 4" ASA Strike
(included). Magnetic Door Contacts included.
DL6200/26D - Cylindrical Trilogy Networx PIN-Code Wireless Ac-
cess Control Lock, as above, with full-metal digital keypad only.
Magnetic Door Contacts included.
PDL8200/26D - Same as PDL6200/26D above, but equipped with
a 13.56MHz Smart Card reader.
This manual includes the hardware installation instructions for the
PDL6200, DL6200 and PDL8200 door locks. The diagrams below
detail the typical small and large system configurations.
WIRELESS LOCK CONFIGURATION OVERVIEW
Up to 63 locks for
each Gateway...
PC Running
DL-Windows
Software
EXPANDABLE
Lock
#1...
...Lock
#63
...Lock
#2000
Router
Small Network Support
...Up to 32 Gateways
for each system
GATEWAY
#32
GATEWAY
#1
Existing
Corporate
Ethernet
Network
Up to 63 locks for
each Gateway...
PC Running
DL-Windows
Software
EXPANDABLE
Lock
#1...
...Lock
#63
...Lock
#2000
Large Network Support
...Up to 32 Gateways
for each system
GATEWAY
#32
GATEWAY
#1
4
INSTALLATION JIG
1. If the 2-1/8" hole already exists, use optional Alarm Lock
Installation Jig to ensure accurate locating and drilling of
3/8" and 5/16" thru-bolt holes.
2. For best results, align the Installation Jig to door with a
square and clamp to door before drilling See Fig. 2.
Note: Always protect the door surface from damage
when using jigs, clamps and other tools.
LATCH INSTALLATION
1. Drill 1" diameter hole for latch.
2. Mortise for latch front. Insert latch and fasten with two
screws supplied.
Note: It is important that both 1" hole and the 2-1/8"
hole be on the same horizontal center line.
DOOR PREPARATION
1. Fold and place template on high edge of door at the rec-
ommended height from floor. See Fig. 1.
2. Mark hole centers on door and door edge.
3. Drill 3/8" thru-bolt holes first, then drill the 2-1/8" hole.
For Hardwood Doors:
Notch on both sides of the 2-1/8" hole to accommo-
date mounting plate tabs.
For Hollow Metal Doors:
Requires horizontal and vertical lock and latch case
support (provided by door manufacturer).
4. Drilling the hole for the supplied Door Contact (labeled
"DOOR CONTACT PREP" on template) is only necessary if
the two white "Remote Input" wires inside the lock (see
Fig. 14) will be used for Door Monitoring. If the Door
Monitoring features will NOT be programmed, and the
two white "Remote Input" wires will either not be used
or used for a "Remote Release" only, there is NO
need to drill the Door Contact hole. (Note: Lock pro-
gramming is performed after lock is installed on the
door; in addition, these instructions will henceforth
assume the Door Contact will need to be installed).
Door Contact Hole: For Hardwood Doors:
Drill a 1/4" hole in door edge to the 1" hole as shown in
Fig. 2. Then use a ¾" bit to enlarge this hole to a
depth of " to allow the Door Contact to fit flush.
Door Contact Hole: For Hollow Metal Doors:
Drill a ¾" hole into the metal surface of the door edge.
IMPORTANT: Be sure to remove all metal burrs from
connector cable hole--sharp edges will eventually wear
away wire insulation.
5. Drill all remaining holes in template as required.
FIG. 3: LATCH INSTALLATION
FIG. 2: ALARM LOCK INSTALLATION JIG
1" (25.4mm)
Diameter hole for
wires
INSIDE MOUNTING PLATE HOLES
5/16" (8mm) diameter
DOOR
CONTACT HOLE
3/4" (19mm)
diameter
C
OF DOOR
EDGE
L
1-3/4" (44MM)
OR
1-3/8" (35MM)
DOOR
THICKNESS
VERTICAL
C
OF
LOCK
L
MARK
HEIGHT
LINE
HORIZONTAL
C
OF
LEVER
L
FIG. 1: FOLD AND PLACE TEMPLATE ON DOOR
5
LOCK PREPARATION
Separate the inside housing from the outside housing as
follows:
1. See Fig. 6 for an image of the inside lever catch. De-
press the inside lever catch by inserting the lever release
pin through the oval hole located in the inside housing
and through the small round hole in the lever shaft.
While depressing the lever catch, pull off the lever (jiggle
lever if needed).
2. Depressing this lever catch also allows the inside hous-
ing to be separated from the outside housing. Use a
small screwdriver to depress the lever catch (the lever
catch is circled in Fig. 6) and pull the inside housing
away from the outside housing.
STRIKE INSTALLATION
1. Align strike with the latch.
2. Trace strike outline on the door jamb.
3. Mortise jamb and install dust box and strike.
DOOR CONTACT MAGNET INSTALLATION (JAMB)
1. With the door closed, place a mark on the inside door
jamb directly opposite the Door Contact hole drilled in
the door.
2. For one of the two Door Contact (magnet) types provid-
ed with your lock, note its dimensions in the image
above. Drill into the door jamb as follows:
For Hardwood Jambs:
 For the thinner contact (above right image): Drill
a 3/8" hole 7/8" deep for the magnet side of the Door
Contact.
 For the thicker contact (above left image): Drill a
3/4" hole 7/8" deep for the magnet side of the Door
Contact.
For Hollow Metal Jambs:
 Use either a 3/8" or 3/4" bit (depending on type) to
drill a hole into the surface for the Door Contact.
Insert the magnetic Door Contact in the hole; the contact
sits flush with the jamb when fully inserted. Ensure a
secure fit by using adhesive appropriate for the material.
FIG. 5: INSERT LEVER RELEASE PIN TO DEPRESS THE
LEVER CATCH
FIG. 6: PUSH IN LEVER CATCH (CIRCLED)
FIG. 4: STRIKE INSTALLATION
FIG. 4A: INSERT DOOR CONTACT (MAGNET) IN JAMB
Φ 31/32" Φ 7/16"
6
LOCK INSTALLATION
INSTALL OUTSIDE LOCK BODY
1. Insert motor wire plug through the large 2 1/8" hole; insert
the ribbon cable and Lever Monitor Switch plug (orange
wires) through the 1" hole as shown in Fig. 7. Insert Door
Contact wires into hole in door edge and pull wires
through the 1" hole as shown in Fig. 7.
2. Insert outside lock body into door and be sure to properly
engage the lock body with the latch as shown in Fig. 8.
The latch yoke must engage the lock body housing and
the tailpiece must engage the retractor.
ADJUSTING FOR DOOR THICKNESS
Plastic spacers either add or subtract the distance between
the rose plates. Each spacer represents 1/8" of door thick-
ness. Locks are factory assembled for 1 3/4" thick doors
using 3 plastic spacers.
For other door thicknesses:
1. Remove outside lever as follows: Insert key into outside
cylinder, turn clockwise 45 degrees. Depress the outside
lever catch by inserting the lever release pin through the
oval hole located in the outside housing and through the
small round hole in the lever shaft. While depressing the
lever catch, pull off the lever (jiggle lever if needed).
2. Remove outside housing and unscrew outside rose plate.
For 1 5/8" door, remove one plastic spacer.
For 1 7/8" door, add one plastic spacer.
3. Screw mounting rose plate up to the spacers.
4. Reassemble outside housing and lever.
For other door thicknesses, consult factory.
TO REVERSE LEVER HANDING
With the inside lever and housing off:
1. Insert key into outside cylinder, turn clockwise 45 degrees
and depress the lever catch. Pull lever off.
FIG. 10: REVERSE LEVER HANDING
FIG. 8: VIEW FROM INSIDE OF DOOR
FIG. 9: ADJUST DOOR THICKNESS
OUTSIDE
MOUNTING
ROSE PLATE
PLASTIC SPACERS
FIG. 7: INSTALL OUTSIDE LOCK BODY
DOOR
CONTACT
DOOR
CONTACT
WIRE
ORANGE
WIRES
RIBBON
CABLE
MOTOR
WIRE
7
2. Use the outside spindle to rotate the lock body 180 de-
grees. Be sure lever catch (shown in Fig. 6) faces the
door edge. If necessary, depress the lever catch to allow
the outside spindle to rotate 180 degrees.
3. With key in cylinder untouched (still at 45 degrees clock-
wise), position lever on spindle and press until lever catch
engages. Remove key and test lever for proper engage-
ment by turning and pulling. For IC models, see Fig. 20.
INSTALL INSIDE TRIM
1. Place the inside rose plate over spindle and on door.
Align the two slots with the two 3/8" holes in door (the
rose plate is marked with "TOP", circled in Fig. 12) and
the bent tabs facing door (the bent tabs bite into wooden
doors, preventing its rotation; for metal doors, drill small
holes to allow the rose plate to sit flush against door).
Fasten with two 8-32 x 1 1/4 Phillips pan head screws
through the inside rose, engaging the outside lock body.
Do not over-tighten.
2. Position inside mounting plate and, without pinching or
cutting the wires, pull the Door Contact wires, the ribbon
cable and the Lever Monitor Switch plug (orange wires)
through the mounting plate opening.
The two white "Remote Input" wires (see Fig. 14) can
be programmed as a "Remote Release" or for "Door
Monitoring" (programming is performed after lock is
installed on the door):
 When a "Remote Release" is desired
(factory default), connect the two white "Remote
Input" wires inside the lock to a normally open
contact switch (switch is shorted/closed to un-
lock the lock).
 When "Door Monitoring" is desired, connect
these two white "Remote Input" wires to the
supplied Door Contact wires (when the door is
closed the contacts are also "closed").
Note: After physically installing the lock,
see the programming instructions Function 67
"Door Ajar Monitor On" and/or "Forced Door
Detect On".
Fasten inside mounting plate with two 6 x ¾ flat head
sheet metal screws and two 8-32 x 1 flat head machine
screws as shown in Fig 13 (do not over-tighten). The
two bottom screws are optional. Note: Be sure the
mounting plate is perfectly vertical before installing sheet
metal screws. See Fig. 13 for screw locations. Note: As
you tighten the screws, the inside mounting plate pulls in
and secures the outside lock body to the door.
IMPORTANT: See Fig. 11 and 13: The motor wire
must come through either slot and be secured by the mo-
tor cable notch without pinching or cutting the wire.
FIG. 11: INSTALL INSIDE TRIM
INSIDE MOUNTING PLATE
DOOR CONTACT
WIRES: CONNECT
TO TWO WHITE
"REMOTE INPUT"
WIRES (SEE FIG. 14)
FOR DOOR
MONITORING
MOTOR
WIRE
BENT
TABS
INSIDE ROSE
PLATE SLOTS FOR MOTOR WIRE (BEWARE OF
ACCIDENTALLY CUTTING WIRES)
BEWARE OF
CUTTING THE
WIRES AT THE
PLATE OPENING
RIBBON CABLE
LEVER MONITOR
SWITCH
(ORANGE WIRES)
DOOR
CONTACT
MOTOR
WIRE
FIG. 12: INSIDE ROSE PLATE INSTALLATION
FIG. 13: INSIDE MOUNTING PLATE INSTALLATION
HOLES FOR 6 x ¾
FLAT HEAD SHEET
METAL SCREWS
USE 8-32 x 1 FLAT
HEAD MACHINE
SCREWS
OPTIONAL HOLES
FOR 6 x ¾ FLAT
HEAD SHEET
METAL SCREWS
INSIDE
MOUNTING
PLATE
MOTOR WIRE
PULL RIBBON
CABLE AND
ORANGE
WIRES
THROUGH
HOLE
(ORANGE
WIRES NOT
SHOWN)
FOR DOOR
MONITORING,
CONNECT DOOR
CONTACT WIRES
TO THE TWO
WHITE "REMOTE
INPUT" WIRES
(DOOR CONTACT
WIRES NOT
SHOWN)
8
3. See Fig. 14. Before placing the inside housing onto the
lock, connect the Lever Monitor Switch plugs (orange
wires), plug the ribbon cable, motor wire and Auxiliary
Power/Remote Input plug into their receptacles on the
inside housing circuit board (these plugs and sockets fit
only one way--do not force them). Seal the connectors
with dielectric grease (included). Do not allow the wires
to cross or lay on top of each other. Jiggle the connector
cable to be sure the wire opening does not pinch wires
before fastening bolts.
4. Place inside housing
over the spindle (see
Fig. 15). Depress the
lever catch (use a
screwdriver pointed in-
side the spindle) and
push housing flush
against door. Be sure
that all wires are
through the housing
before tightening the
two 10-32 x 2 1/4" thru-
bolts.
5. Secure the top of the inside housing to the inside mount-
ing plate with two black 4-40 x ¼ flat head Phillips or
spanner head security screws. See Fig. 16.
6. Plug the battery connector into its receptacle. See Fig.
17. Upon connection of the battery pack, you will hear
three beeps.
7. Insert the battery pack into inside housing as shown in
Fig. 18.
8. Secure the battery cover to the inside housing with two
black 4-40 x ¼ flat head Phillips or spanner head se-
curity screws. See Fig. 19.
FIG. 16: SECURE TOP OF INSIDE HOUSING
FIG. 19: SECURE BATTERY COVER
FIG. 18: INSERT BATTERY PACK INTO HOUSING
FIG. 14: RECEPTACLES LOCATED IN THE INSIDE HOUSING
RIBBON CABLE
EXTERNAL RELAY
CONTACTS
MOTOR WIRES
BATTERY WIRES
AUXILIARY POWER /
REMOTE INPUT (ANTENNA)
FIG. 15: TIGHTEN THRU-BOLTS
SPINDLE
FIG. 17: CONNECT THE BATTERY PACK
BATTERY CONNECTOR
FROM CIRCUIT BOARD
CONNECTOR FROM
BATTERY PACK
9
ATTACHING LEVERS AND LOCKSETS
Interchangeable Core (IC) Models:
Skip to the section, "INTERCHANGEABLE (IC) LOCKS"
below.
Standard Levers and Cylinders:
Standard levers and standard lock cylinders are both in-
cluded in non-IC lock models.
a. Install the tailpiece, cylinder retainer and cylinder into
the standard lever as shown in Fig. 20.
b. Attach the outside lever by first inserting the metal key
into the outside lock cylinder and turning the key 45° in
either direction.
c. Insert the lever on the spindle and push the lever in
until it engages with the lever catch (it may be neces-
sary to turn the key back and forth while installing the
lever).
d. Install the inside lever in the same manner as the out-
side.
e. Test both levers to be sure they are on securely and
operate without binding. Be sure the outside key re-
tracts the latch when the key is turned in either direc-
tion.
BE SURE TO TEST THE LEVERS AND CYLINDERS
FOR PROPER OPERATION BEFORE CLOSING
DOOR.
INTERCHANGEABLE (IC) LOCKS
Interchangeable (IC) cores require special levers. If neces-
sary, remove both standard levers (with their standard cylin-
ders) before proceeding. (To remove standard levers, insert
key into cylinder, turn key 45° in either direction, depress the
lever catch and pull off lever). Interchangeable (IC) cores
and their specialized levers are both available from your
Alarm Lock dealer.
INSTALL INTERCHANGEABLE (IC) CORES
1. Insert outside IC lever on spindle and push in until it en-
gages with the lever catch.
2. Insert control key in IC core and turn clockwise.
3. Insert IC core tailpiece (shown in Fig. 21 and Fig. 22) into
interchangeable core. Use ONLY an Alarm Lock© IC
core tailpiece.
4. With control key in IC core, insert core fully into lever.
5. Turn key counterclockwise and remove control key.
CHANGING AN EXISTING IC CORE
1. Remove the existing IC core by inserting its control key,
then turning the key clockwise and pulling the key to re-
move the core. Set core aside.
2. Insert Alarm Lock IC tailpiece with washer into new core.
3. Insert new control key into new core, turn clockwise.
4. Insert new core into lever and turn key counterclockwise
to lock in position.
5. Remove new control key.
REMOVING THE IC CORE & LEVER
1. Remove the existing IC core by inserting the control key,
then turning the key clockwise and pulling the key to re-
move the core.
2. Use a screwdriver to CAREFULLY push inside of lever
catch to the side (see Fig. 23). Pull off the IC lever.
FIG. 20: STANDARD CYLINDER-LEVER, TAILPIECE
AND RETAINER.
FIG. 22: INSTALL INTERCHANGEABLE (IC) CORE
INTERCHANGEABLE
(IC) CORE
INTERCHANGEABLE
(IC) CORE TAILPIECE
FIG. 23: REMOVING THE IC CORE LEVER
LEVER CATCH
FIG. 21: STANDARD AND IC CORE TAILPIECE VARIETIES
SMALL FORMAT IC
CORE FOR USE WITH
BEST, ARROW, FALCON,
MEDICO, MARKS USA,
KSP: #HW598
Washer #WA160
REPLACEMENT
TAILPIECE
FOR SCHLAGE
#HW580
STANDARD
ALARM LOCK
TAILPIECE
#HW597
Washer #WA160
REPLACEMENT
TAILPIECE FOR
LORI AND ILCO
#HW620
Washer #WA160
10
PROGRAMMING
Your lock can be programmed (and re-programmed again
and again) to suit your changing requirements. Instead of
distributing metal keys, distribute User Codes -- and delete
them from the lock firmware when needed. To program
your DL/PDL6200 and PDL8200 lock, see the lock pro-
gramming instructions.
TROUBLESHOOTING
Electronic Trouble:
Lock incorrectly operates in reverse.
 Solution: Reverse motor wires in connector.
Lock will not accept new codes during programming.
 Solution: Disconnect battery connector, hold down
any button until lock resets, then reconnect and start
programming again.
Lock drains batteries quickly.
 Solution: Check all wires for pinching or cutting.
Check for water damage. If condition persists, consult
factory.
Lock is inoperative.
 Solution: Check batteries for proper polarity and
check for cut wires.
Lock sounds "steady tone" (with red flickering LED) during
lock operation.
 Solution: Low battery signal - replace batteries.
Mechanical Trouble:
Lever pulls off.
 Lever Catch not fully engaged. Lock is not centered on
door. Door too thick. (See Fig. 9).
Unable to assemble outside lever.
 Key and tailpiece orientation are incorrect (See Fig. 21
and 22).
Latch will not fully retract.
 Lock is not properly engaged with latch or misaligned.
Lock is not centered on door (See Fig. 8).
Key binds in lock.
 Lever Catch not fully engaged. Lock is not centered on
door. Check for proper tailpiece and proper orientation
of tailpiece (See Fig. 21 and 22).
WIRE CONNECTIONS
WIRING AND POWER UP
External Power:
Red / Black wires - External 7.5 VDC Power Source
must be used for operation without batteries.
Remote Input:
White / White wires - The two white wires can be pro-
grammed for use as a "Remote Release" or pro-
grammed for "Door Monitoring" (programming is per-
formed at the lock keypad after lock is installed on the
door). When programmed for a "Remote Re-
lease" (factory default), wire to a N/O contact switch
that is closed/shorted to unlock the lock. When pro-
grammed for "Door Monitoring", connect wires to the
supplied Door Contact wires (Note: When the door is
closed the contacts are also "closed"). For Door Moni-
toring functions, see Function 67 in the lock programming
instructions for more information. Door Monitoring func-
tions include "Door Ajar Monitor On" (Function 67, option
40) and "Forced Door Detect On" (Function 67, option
42).
Relay:
COM-Orange / NO-Green / NC-Yellow - See Function
67 in the programming instructions for programming op-
tions for the Relay.
Wiring to Disarm a Burglary Control Panel:
See the programming instructions WI1790 for additional
information.
FIG. 24: WIRE CONNECTIONS
1. Ground (no connections)
2. Battery Wires
3. Motor Wire
4. Auxiliary Power / Remote Input (Programmable)
Wire colors in supplied plug are as follows:
Auxiliary Power:
Red: 6-9VDC
Black: Ground
Remote Input (Programmable):
Two White Wires can be used for either a "Remote Re-
lease" or for "Door Monitoring" functions:
For "Remote Release" (factory default): Wire to a N/O
contact switch (short to unlock the lock).
For "Door Monitoring": Connect to the supplied Door Con-
tact wires. Note: When the door is closed the contacts are
also "closed". See the below "WIRING AND POWER UP",
Remote Input description for more details.
5. Ribbon Cable
6. External Relay Contacts
1 2 3 4 5 6
11
POWER UP
1. When applying power to the lock for the first time,
stop and follow the procedure outlined in "Quick
Start, First time Power Up" further in this manual.
2. When power is re-applied to a lock that was already
operational, proceed as follows:
3. Disconnect battery pack connector.
4. With battery power disconnected, press and hold
down ; for 10 seconds to insure discharge of all
capacitors.
5. Re-connect battery pack (lock will sound 3 short
beeps). If beeps are not heard, then restart at step 1.
6. Do not press any keys for 15 seconds.
7. After 15 seconds, the LED will flash red 6 times and
6 beeps will sound.
8. The lock is now ready for use. The pre-existing pro-
gram is loaded from fixed memory. Set the clock
using functions 38, 39 and 40.
ERASE ALL PROGRAMMING
(The "out of box" factory default will be loaded)
1. Remove the battery pack.
2. With battery power disconnected, press and hold
down ; for 10 seconds to ensure discharge of all
capacitors.
3. Re-install the battery pack (lock will sound 3 short
beeps). If beeps are not heard, then restart at step 1.
4. Within 5 seconds after hearing the 3 short beeps,
press and hold ; until the lock begins to beep,
then release.
5. A series of 5 RED LED and 5 beeps will be heard
followed by 10 seconds of silence, then 3 GREEN
LED's and 3 fast beeps.
All settings and programming have been erased and
the lock is now ready for use. Note: All lock pro-
gramming can also be erased (without need to dis-
connect the batteries) by entering Function 99.
BATTERY REPLACEMENT
When a valid code is entered and the batteries are
weak, the red LED will turn on and the sounder will
sound a steady tone. Always replace weak batteries as
soon as possible.
CAUTION: Do not press any keys while batteries are
disconnected or you may erase the real-time clock set-
tings.
1. At the back of the lock, remove the screw at the bot-
tom of the lock housing and remove the cover.
2. Pull out the battery pack and quickly replace with a
new battery pack - within 1 minute.
3. If you do not hear the 3 beeps when power is re-
applied, all programming and settings have been re-
tained, and the lock is ready for use. Go to step 5.
4. If you do hear 3 beeps when power is re-applied, do
not press any keys for 15 seconds. After the 15 sec-
ond period, the LED will flash red 6 times and 6
beeps will sound. Reset the clock using functions 38,
39 and 40.
5. Replace the cover and tighten the screw.
12
ALARM LOCK SYSTEMS, INC. (ALARM LOCK) warrants
its products to be free from manufacturing defects in mate-
rials and workmanship for twenty four months following the
date of manufacture. ALARM LOCK will, within said peri-
od, at its option, repair or replace any product failing to
operate correctly without charge to the original purchaser
or user.
This warranty shall not apply to any equipment, or any part
thereof, which has been repaired by others, improperly
installed, improperly used, abused, altered, damaged, sub-
jected to acts of God, or on which any serial numbers have
been altered, defaced or removed. Seller will not be re-
sponsible for any dismantling or reinstallation charges,
environmental wear and tear, normal maintenance ex-
penses, or shipping and freight expenses required to re-
turn products to ALARM LOCK. Additionally, this warranty
shall not cover scratches, abrasions or deterioration due to
the use of paints, solvents or other chemicals.
THERE ARE NO WARRANTIES, EXPRESS OR IM-
PLIED, WHICH EXTEND BEYOND THE DESCRIPTION
ON THE FACE HEREOF. THERE IS NO EXPRESS OR
IMPLIED WARRANTY OF MERCHANTABILITY OR A
WARRANTY OF FITNESS FOR A PARTICULAR PUR-
POSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU
OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE
PART OF ALARM LOCK.
Any action for breach of warranty, including but not limited
to any implied warranty of merchantability, must be
brought within the six months following the end of the war-
ranty period.
IN NO CASE SHALL ALARM LOCK BE LIABLE TO ANY-
ONE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGES FOR BREACH OF THIS OR ANY OTHER
WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE
LOSS OR DAMAGE IS CAUSED BY THE SELLER'S
OWN NEGLIGENCE OR FAULT.
In case of defect, contact the security professional who
installed and maintains your security system. In order to
exercise the warranty, the product must be returned by the
security professional, shipping costs prepaid and insured
to ALARM LOCK. After repair or replacement, ALARM
LOCK assumes the cost of returning products under war-
ranty. ALARM LOCK shall have no obligation under this
warranty, or otherwise, if the product has been repaired by
others, improperly installed, improperly used, abused, al-
tered, damaged, subjected to accident, nuisance, flood,
fire or acts of God, or on which any serial numbers have
been altered, defaced or removed. ALARM LOCK will not
be responsible for any dismantling, reassembly or reinstal-
lation charges, environmental wear and tear, normal
maintenance expenses, or shipping and freight expenses
required to return products to ALARM LOCK. Additionally,
this warranty shall not cover scratches, abrasions or dete-
rioration due to the use of paints, solvents or other chemi-
cals.
This warranty contains the entire warranty. It is the sole
warranty and any prior agreements or representations,
whether oral or written, are either merged herein or are
expressly cancelled. ALARM LOCK neither assumes, nor
authorizes any other person purporting to act on its behalf
to modify, to change, or to assume for it, any other warran-
ty or liability concerning its products.
In no event shall ALARM LOCK be liable for an amount in
excess of ALARM LOCK's original selling price of the
product, for any loss or damage, whether direct, indirect,
incidental, consequential, or otherwise arising out of any
failure of the product. Seller's warranty, as hereinabove set
forth, shall not be enlarged, diminished or affected by and
no obligation or liability shall arise or grow out of Seller's
rendering of technical advice or service in connection with
Buyer's order of the goods furnished hereunder.
ALARM LOCK RECOMMENDS THAT THE ENTIRE SYS-
TEM BE COMPLETELY TESTED WEEKLY.
Warning: Despite frequent testing, and due to, but not
limited to, any or all of the following; criminal tampering,
electrical or communications disruption, it is possible for
the system to fail to perform as expected. ALARM LOCK
does not represent that the product/system may not be
compromised or circumvented; or that the product or sys-
tem will prevent any personal injury or property loss by
burglary, robbery, fire or otherwise; nor that the product or
system will in all cases provide adequate warning or pro-
tection. A properly installed and maintained alarm may
only reduce risk of burglary, robbery, fire or otherwise but
it is not insurance or a guarantee that these events will not
occur. CONSEQUENTLY, SELLER SHALL HAVE NO LIA-
BILITY FOR ANY PERSONAL INJURY, PROPERTY
DAMAGE, OR OTHER LOSS BASED ON A CLAIM THE
PRODUCT FAILED TO GIVE WARNING. Therefore, the
installer should in turn advise the consumer to take any
and all precautions for his or her safety including, but not
limited to, fleeing the premises and calling police or fire
department, in order to mitigate the possibilities of harm
and/or damage.
ALARM LOCK is not an insurer of either the property or
safety of the user's family or employees, and limits its lia-
bility for any loss or damage including incidental or conse-
quential damages to ALARM LOCK's original selling price
of the product regardless of the cause of such loss or
damage.
Some states do not allow limitations on how long an im-
plied warranty lasts or do not allow the exclusion or limita-
tion of incidental or consequential damages, or differenti-
ate in their treatment of limitations of liability for ordinary or
gross negligence, so the above limitations or exclusions
may not apply to you. This Warranty gives you specific
legal rights and you may also have other rights which vary
from state to state.
ALARM LOCK LIMITED WARRANTY
Page 1 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 2 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 3 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 4 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 5 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 6 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 7 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 8 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 9 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 10 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 11 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST
Page 12 of 12 - Alarm Lock PDL6200_DL6200_PDL8200_WI2024B.04_INST DL6200, PDL6200 And PDL8200 Installation Instructions DL6200 WI2024B.04 INST

Navigation menu