OmniSwitch 6850 Series
Getting Started Guide

060208-10, Rev. C
June 2007

Warning. Only personnel knowledgeable in basic electrical and mechanical procedures should install or maintain this
equipment.
Lithium Batteries Caution. There is a danger of explosion if the Lithium battery in your chassis is incorrectly replaced.
Replace the battery only with the same or equivalent type of battery recommended by the manufacturer. Dispose of used
batteries according to the manufacturer’s instructions. The manufacturer’s instructions are as follows:

Return the module with the Lithium battery to Alcatel-Lucent. The Lithium
battery will be replaced at Alcatel-Lucent’s factory.
The features and specifications described in this guide are subject to change without notice.
Copyright © 2007 by Alcatel-Lucent. All rights reserved. This document may not be reproduced in whole or in part without
the express written permission of Alcatel-Lucent.
Alcatel-Lucent® and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. Xylan®, OmniSwitch®,
OmniStack®, and Alcatel-Lucent OmniVista® are registered trademarks of Alcatel-Lucent.
OmniAccess™, Omni Switch/Router™, PolicyView™, RouterView™, SwitchManager™, VoiceView™, WebView™,
X-Cell™, X-Vision™, and the Xylan logo are trademarks of Alcatel-Lucent.
This OmniSwitch product contains components which may be covered by one or more of the following U.S. Patents:
• U.S. Patent No. 6,339,830
• U.S. Patent No. 6,070,243
• U.S. Patent No. 6,061,368
• U.S. Patent No. 5,394,402
• U.S. Patent No. 6,047,024
• U.S. Patent No. 6,314,106
Alcatel-Lucent
• U.S. Patent No. 6,542,507
26801 West Agoura Road
• U.S. Patent No. 6,874,090
Calabasas, CA 91301
(818) 880-3500 FAX (818) 880-3505
US Customer Support: (800) 995-2696
International Customer Support: (818) 878-4507
Internet: service.esd.alcatel-lucent.com

Table of Contents
OmniSwitch 6850 Series. . . . . . . . . . . . . . .

1

Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installing the Hardware

Connections and Cabling

. . . . . . . . . . . . . 11

Connecting the Serial Cable . . . . . . . . . . . . . . . . . . 11

............... 3

Serial Connection Default Settings . . . . . . . . . . . . . 11

Items Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Booting OmniSwitch 6850 Series
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Environmental Requirements . . . . . . . . . . . . . . . 3
Electrical Requirements . . . . . . . . . . . . . . . . . . . 3
NEBS GR-1089 Compliance Requirements . . . . 3
Weight Considerations . . . . . . . . . . . . . . . . . . . . 4

Booting a Standalone Switch . . . . . . . . . . . . . . . . . 12

Your First Login Session . . . . . . . . . . . . . . . 14
Logging in to the Switch . . . . . . . . . . . . . . . . . . . . . 14

Items Included . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Assigning an IP Address to the Switch . . . . . . . . . 15

Unpacking and Initial Setup . . . . . . . . . . . . . . . . . . . 5
Unpacking the Chassis . . . . . . . . . . . . . . . . . . . . 5
Recommendations . . . . . . . . . . . . . . . . . . . . 5
Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 5

Unlocking Session Types . . . . . . . . . . . . . . . . . . . . 16

Setting Up the Switch . . . . . . . . . . . . . . . . . . . . . . . . 6
Airflow Considerations . . . . . . . . . . . . . . . . . . . . 6
Installation Options . . . . . . . . . . . . . . . . . . . . . . . 7
Installing the Switch on a Tabletop or Bench . . . 7
Tabletop Mounting Steps . . . . . . . . . . . . . . . 7
Rack-Mounting the Switch . . . . . . . . . . . . . . . . . 8
Rack Mounting Steps . . . . . . . . . . . . . . . . . . 8

Changing the Login Password . . . . . . . . . . . . . . . . 17
Setting the System Time Zone . . . . . . . . . . . . . . . . 18
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . 18
Setting Optional System Information . . . . . . . . . . . 18
Specifying an Administrative Contact . . . . . . .18
Specifying a System Name . . . . . . . . . . . . . . . .19
Specifying the Switch’s Location . . . . . . . . . . .19
Viewing and Saving Changes . . . . . . . . . . . . . . . . . 19

Installing Combo Port SFPs . . . . . . . . . . . . . . . . . . 10
Installing Backup Power Supply Components . . . . 10

June 2007

iii

Files and Directories . . . . . . . . . . . . . . . . . . . .

20

Boot and Image Files . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
boot.params File . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
boot.cfg File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Image Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Working and Certified Directories . . . . . . . . . . . . . . . . 22
Working Directory . . . . . . . . . . . . . . . . . . . . . . 22
Certified Directory . . . . . . . . . . . . . . . . . . . . . . 23

Using WebView

. . . . . . . . . . . . . . . . . . . . . . . . . 26

Browser Compatibility . . . . . . . . . . . . . . . . . . . . . . 26
Logging In to WebView . . . . . . . . . . . . . . . . . . . . . 26
Navigating WebView . . . . . . . . . . . . . . . . . . . . . . . 27
Online Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Additional Information . . . . . . . . . . . . . . . . . . . . . . 29
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

iv

June 2007

OmniSwitch 6850 Series

OmniSwitch 6850-24L
24
23
22
21
24

20
19

23

18

22

17

1 LASER

21

16

PRODUCT

CLASS

15
14
13
12
11
10
9
8
7

48

6

47

5

46

4

45

3

44

2

43

1

OmniSwitch 6850-48L

42
41

BPS
40

PWR

39

PRI

38

OK

37

24L

36

6850-

35

USB

witch

34
33

OmniS

32
31
30
29
28
27
26

OmniSwitch 6850-P24L

25

le

24

Conso

23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1

BPS
PWR
PRI
OK

48L
6850USB

witch
OmniS

4
3
PRODUCT

2
1 LASER

1
CLASS

le

24

Conso

23
22
21
24

20
19

23

18

22

17

PRODUCT

1 LASER

21

16

CLASS

15
14
13
12
11
10
9
8
7

48

6

47

5

46

4

45

3

44

2

OmniSwitch 6850-P48L

43

1

42
41

BPS
40

PWR

39

PRI

38

OK

37

P24L

36

6850-

35

USB

witch

34
33

OmniS

32
31
30
29
28
27
26
25

le

24

Conso

23

OmniSwitch 6850-U24X

22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1

BPS

The OmniSwitch 6850 Series is an advanced fixed
configuration family of Ethernet switches. These switches
provide wire rate Layer 2 forwarding and Layer 3 routing with
advanced services.
They are fixed configuration, triple-speed (10/100/1000)
switches that provide increased network performance,
improved application response times, secure the LAN, and
enhance user productivity by maximizing mobility, network
capacity, and services over existing category 5/5E/6 cabling.

PWR
PRI
OK

P48L
6850USB

witch

24
23

OmniS

22

4

25

21

3

24

20

PRODUCT

2
1 LASER

1

21

19

PRODUCT

23

18

CLASS

19

17

1 LASER

CLASS

17
le
24

Conso
16

22

15
14

20

15

13
12

OmniSwitch 6850-24

18

13

11
10
11

9
9

16
8

14

7
6

12

7

5
4

10

5

3
2
3

1
1

BPS

8

PWR
PRI
6

OK
4

U24X
6850-

26

2

USB

witch
OmniS

25
PRODUCT
1 LASER

25
CLASS

26

le
Conso

48
47
46
45

BPS

44

PWR

43

PRI

OmniSwitch 6850-48

42

OK

41
40

24

39

6850witch

Refer to the User Manual CD for additional hardware and
software OmniSwitch documentation.

38
37

USB

OmniS

36
35
34
33
32
31
30
29
28

le

27

Conso

26
25

OmniSwitch 6850-24X

24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1

BPS
PWR
PRI
OK

48
6850USB

witch
OmniS

4
3
PRODUCT

2
1 LASER

1
CLASS

le
Conso

24
23
22
21
24

20
19

23

18

PRODUCT

22

17

1 LASER

21

16

CLASS

15
14
13
12
11
10
9
8
7
6
5
4
48

3
47

2
46

1
45

BPS

44

PWR

OmniSwitch 6850-48X

43

PRI

42
41

OK
40
39

24X

38

6850-

26

37

USB

witch
OmniS

36
35

25
34
33

PRODUCT
1 LASER

25

32
31

CLASS

26

30
29
28

le

27
26

Conso
25
24
23
22
21
20
19
18
17
16
15
14
13

OmniSwitch 6850-P24

12
11
10
9
8
7
6
5
4
3
2
1

BPS
PWR
PRI
OK

48X
6850-

50

USB

witch
OmniS

49
PRODUCT

49

1 LASER
CLASS

50

le
Conso

24
23
22
21
20

24

19

23

18

22

17

PRODUCT

1 LASER

21

16

CLASS

15
14
13
12
11
10
9
8
7
6
5
4
3

48

2

47

1

46
45

BPS

44

PWR

43

PRI

42
41

OK
40

P24

39

OmniSwitch 6850-P48

38

685037

USB

witch
OmniS

36
35
34
33
32
31
30
29
28

le

27

Conso

26
25
24
23
22
21
20
19
18
17

OmniSwitch 6850-P24X

16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1

BPS
PWR
PRI
OK

P48
6850USB

witch
OmniS

4
3
PRODUCT

2
1 LASER

1
CLASS

le
Conso

24
23
22
21
24

20
19

23

18

22

17

21

16

PRODUCT

1 LASER

CLASS

15
14
13
12
11
10
9
8
7
6
5
4
3

48

2

47

1

46

OmniSwitch 6850-P48X

45

BPS
44

PWR

43

PRI

42

OK

41
40

P24X

39

6850-

38

26

USB

witch

37

OmniS

36

25

35
34

PRODUCT

33

1 LASER

25

32

CLASS

31

26
30
29
28

le

27

Conso

26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1

BPS
PWR
PRI
OK

P48X
6850-

50

USB

witch
OmniS

49
PRODUCT

49
50

1 LASER
CLASS

le
Conso

June 2007

OmniSwitch 6850 Series

1

Related Documentation
The following are the titles and descriptions of all the
OmniSwitch 6850 Series user documentation included in the
User Manual CD:

directory architecture, image rollback protections,
authenticated switch access, managing switch files,
system configuration, using SNMP, and using web
management software (WebView).
•

OmniSwitch 6800/6850/9000 Network Configuration
Guide

• OmniSwitch 6850 Series Getting Started Guide

Includes network configuration procedures and
descriptive information on all the major software
features and protocols included in the base software
package. Chapters cover Layer 2 information (Ethernet and VLAN configuration), Layer 3 information
(static routes), security options (authenticated
VLANs), Quality of Service (QoS), and link
aggregation.

Describes the hardware and software procedures for
getting an OmniSwitch 6850 Series switch up and
running. Also provides information on fundamental
aspects of OmniSwitch hardware components and
software architecture.
• OmniSwitch 6850 Series Hardware Users Guide

Complete technical specifications and procedures for
all OmniSwitch 6850 Series hardware, including
chassis, power supplies, fans, combo ports, stacking
procedures, optional backup power supplies, etc.
• OmniSwitch CLI Reference Guide

Complete reference to all CLI commands supported on
the OmniSwitch 6850 Series. Includes syntax
definitions, default values, examples, usage
guidelines, and CLI-to-MIB variable mappings.
• OmniSwitch 6800/6850/9000 Switch Management

Guide

•

OmniSwitch 6800/6850/9000 Advanced Routing
Configuration Guide
Includes network configuration procedures and
descriptive information on all the software features and
protocols included in the advanced routing software
package. Chapters cover multicast routing (DVMRP
and PIM-SM) and OSPF.

• OmniSwitch Transceivers Guide

Includes information on Small Form Factor Pluggable
(SFPs) and 10 Gbps Small Form Factor Pluggables
(XFPs) transceivers.

Includes procedures for readying a switch for
integration into a network. Topics include the software
2

OmniSwitch 6850 Series

June 2007

Installing the Hardware
Items Required

Electrical Requirements

In addition to the materials and components provided in the
OmniSwitch 6850 Series shipment, you must provide the
following items in order to complete this installation:

OmniSwitch 6850 Series switches have the following general
electrical requirements:

• Grounding wrist strap
• Phillips screwdriver
• Serial cable
• Rack mount screws, if applicable

Site Preparation
Environmental Requirements
OmniSwitch 6850 Series switches have the following environmental and airflow requirements:
• The installation site must maintain a temperature

between 0° and 45° Celsius (32° and 113° Fahrenheit)
and not exceed 95 percent maximum humidity (noncondensing) at any time.
• Be sure to allow adequate room for proper air

ventilation and access at the front, back, and sides of
the switch. No clearance is necessary at the top or
bottom of the chassis. Refer to page 6 for minimum
clearance requirements.
June 2007

• Each switch requires one grounded AC power source.
• Grounded AC power source must be 110V for North

American installations (220V international).
• Each supplied AC power cord is approximately 2

meters (6.5 feet) long. Do not use extension cords.

NEBS GR-1089 Compliance Requirements
The following notes and warnings apply to all NEBS
compliant platforms.
Grounding requirements: To ground the equipment properly, connect a Panduit Corporation UL listed Lug, P/N:
LCD8-10AL to the two threaded holes located on the rear of
each chassis and power supply module. All connections should
be made using 8AWG copper conductors.
Use Panduit Corporation, P/N: CT-940CH for crimping. (Each
Module must have its own grounding conductor.)
(GR-1089 requires treatment of ground connections and
painted surfaces as needed during installation.)
Installing the Hardware

3

All surfaces that are used for intentionally grounding the EUT
shall be brought to a bright finish and an anti oxidant solution
must be applied to the surfaces being joined.
Non-conductive coatings (such as lacquer and enamel) must be
removed from threads and other contact surfaces to assure
electrical conductivity.

Weight Considerations
A single OS6850 weighs approximately 14 lbs
(6.24 Kgs). A stack of eight OS6850 switches weighs
approximately 112 lbs (50 Kgs).

(Thread forming screws with paint piercing washers may be
used for this purpose during installation)
Warning. The intra-building interfaces of this platform,
including Gigabit Ethernet, are suitable for connection to
intra-building or unexposed wiring or cabling only with
shielded and grounded cables at both ends. The intra-building
ports of the equipment must not be metallically connected to
interfaces that connect to the OSP or its wiring.
Note. All bare conductors must be coated with an appropriate antioxidant compound before crimp connections are
made. All unplated connectors, braided strap, and bus bars
are to be brought to a bright finish and then coated with an
antioxidant before connecting them.

4

Installing the Hardware

June 2007

Items Included

Unpacking and Initial Setup

Your OmniSwitch 6850 Series switch order includes the
following items:

Unpacking the Chassis

• OmniSwitch 6850 Series chassis

mount flanges may be pre-installed on some orders)

To protect your OmniSwitch chassis and hardware components from electrostatic discharge (ESD) and physical damage,
read all unpacking recommendations and instructions carefully before beginning.

• Power cord (country-specific)

Recommendations

• Rack mount flanges with attachment screws (rack

• Documentation CD containing a complete set of user

guides for the switch and switch software. Refer to
“Related Documentation” on page 2 for a complete list of
included documentation.
Depending on the items ordered for your specific network
requirements, the following optional items may also be
included:

• Unpack your OmniSwitch chassis as close as possible

to the location where it will be installed.
• Depending on your order, Small Form-Factor Plugga-

bles (SFPs), stacking cables and backup power supply
components may be packaged separately. In order to
greatly reduce exposure to electrostatic discharge
(ESD) and physical damage, do not unpack these items
until they are ready to be installed.

• Stacking cables (per order)
• SFPs (per order)

Instructions
1 Carefully cut the tape along the seam at the top of the

• 10-Gigabit XFPs (per order)

box containing the chassis.

• Backup power supply components and cables

2 Lift the box’s top flaps. Remove any smaller boxes or

(per order)

pouches that are enclosed and set them aside.
3 Lift the chassis out of the packaging.

June 2007

Installing the Hardware

5

4 Carefully remove any foam pads and protective plastic

from the switch chassis.
Note. Alcatel-Lucent provides factory-installed blank
cover plates for empty backup power supply or 10-Gigabit expansion module bays. Do not remove these cover
plates unless a backup power supply or expansion module
is to be installed immediately at the corresponding bay.

5 If you are installing multiple switches in a stacked

configuration, repeat steps 1 through 4 for the remaining
switches that will make up the stack.
6 Once all OmniSwitch 6850 Series switches have been

removed from their packaging, continue to “Setting Up
the Switch.”

Setting Up the Switch
Note. Due to their airflow and access requirements,
OmniSwitch 6850 Series switches cannot be wallmounted.
Airflow Considerations
Be sure that your switch is placed in a well-ventilated, staticfree environment. Always allow adequate clearance at the
front, rear, and sides of the switch.
The following diagram shows recommended minimum clearances for adequate chassis airflow and access to components at
the rear of the chassis:
Rear. 5 inches minimum
at rear of chassis.

Sides. 2 inches minimum
at left and right sides for
chassis airflow.

48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
BPS
PWR
PRI
OK

-48
ch
iSwit

6850
USB

Omn
4
3

CT

PRODU
2
LASER

1
1
CLASS

Front. 6 inches minimum
at front of chassis for
cable access and LED
visibility.

Chassis Top View

6

Installing the Hardware

June 2007

Never obstruct the air vents located at the left and right sides
of the chassis.
Note. Clearance is not required at the top and bottom of
the chassis. For detailed chassis airflow diagrams, refer to
the OmniSwitch 6850 Series Hardware Users Guide.

Note. OmniSwitch 6850 Series switches must be placed
“right side up.” Never attempt to operate a switch positioned on its side.
Tabletop Mounting Steps
To install the switch as a tabletop unit, follow the steps below:

Installation Options
There are two ways in which the OmniSwitch 6850 Series
switches can be installed:
• Tabletop installation
• Rack-mount installation

For information on setting up a switch as a tabletop unit, refer
to “Installing the Switch on a Tabletop or Bench.” For information on rack-mounting the switch, refer to
“Rack-Mounting the Switch” on page 8.

Installing the Switch on a Tabletop or
Bench
OmniSwitch 6850 Series switches can be installed freestanding as tabletop units. Place your switch on a stable, flat, and
static-free surface.

June 2007

1 Position the chassis on the table or bench where it is to

be installed.
2 Be sure that adequate clearance has been provided for
chassis airflow and access to the front, back, and sides of
the switch. For recommended clearances, refer to page 6.
Also, be sure that you have placed the chassis within reach
of all required AC power sources.

If you are placing multiple switches in a stacked configuration, carefully stack the remaining switches, one on top
of the other. Up to eight switches may be stacked to form
a single virtual chassis. Be sure to maintain adequate
clearance at the front, rear, left, and right side of all
switches (see page 6). Also, be sure that you have placed
all switches in the stack within reach of required AC
power sources.
Note. If you are installing a single (i.e., standalone)
switch, continue to “Connections and Cabling” on page 11
for additional setup procedures.

Installing the Hardware

7

Rack-Mounting the Switch
Refer to the important guidelines below before installing the
OmniSwitch chassis in a rack.
• It is recommended that two people install the switch in

the rack—one person to hold the chassis and position it
in the rack, and a second person to secure the chassis to
the rack using attachment screws (not supplied).

• Review page 6 for important chassis airflow and access

recommendations before installing.
Rack Mounting Steps
To rack-mount the switch, follow the steps below:
Note. Rack-mount flanges may come factory-installed in
some cases. If this is the case, skip steps 1 and 2 below.

• Alcatel-Lucent provides two rack-mount flanges with

each OmniSwitch 6850 Series switch. These flanges
support standard 19-inch rack mount installations.
These flanges must be attached to the chassis before
the switch can be rack mounted.
Note. If you are installing the switch in a 23-inch wide
rack, Alcatel-Lucent offers optional 23-inch rack-mounting hardware. For more information, contact your AlcatelLucent representative.

1 Align the holes in the provided rack-mount flanges
with the four threaded holes in the OmniSwitch chassis.
These threaded holes are located in the left and right sides
of the chassis, near the front panel.
2 Attach the flanges to the chassis using the provided

Phillips-head screws. Be sure to tighten each of the screws
firmly using a Phillips screwdriver.

45

• Alcatel-Lucent does not provide rack-mount screws.

Use the screws supplied by the rack vendor.
46

• To prevent a rack from becoming top heavy, it is

recommended that you install heavier equipment at the
bottom of the rack whenever possible.

le
n so
Co

• If you are installing the switch in a relay rack, be sure

to install and secure the rack as per the rack manufacturer’s specifications.
Attaching a Rack-Mount Flange
8

Installing the Hardware

June 2007

3 After the rack-mount flanges are secured to the chas-

7 Once the screws at the bottom of each flange are

sis, mark the holes on the rack where the switch is to be
installed.

secure, install the remaining two rack-mount screws. Be
sure that all screws are securely tightened.

4 Lift and position the switch until the rack-mount

8 If you are installing multiple switches in a rack to form

flanges are flush with the rack post.

a stacked configuration, repeat steps 1 through 7 for all
switches in the stack.

5 Align the holes in the flanges with the rack holes that

were marked in step 3.
6 Once the holes are aligned, insert a rack-mount screw

(not provided) through the bottom hole of each flange.
Tighten both screws until they are secure.

Note. When rack mounting multiple switches in a stacked
configuration, be sure to place all switches in verticallyadjacent rack positions. This will ensure that all required
stacking cables will have adequate length for the installation.

Attaching the Switch to the Rack
Note. Be sure to install the screws in the bottom hole of
each flange, as shown, before proceeding.

June 2007

Installing the Hardware

9

Installing Combo Port SFPs
OmniSwitch 6850 Series switches offer Gigabit Ethernet
combo ports, located on the front panel. These combo ports
support hot-swappable fiber Small Form-Factor Pluggables
(SFPs). For instructions on installing and removing combo
port SFPs, refer to the instruction card provided with the SFP
product.
Note. Combo port preferences are user-configurable via
the system software. Refer to the “Configuring Ethernet
Ports” chapter in the OmniSwitch 6800/6850/9000
Network Configuration Guide for complete details.

Installing Backup Power Supply
Components
For detailed information on installing backup power supply
components—including the backup power supply, connector
cables, and power cords—refer to the OmniSwitch 6850 Series
Hardware Users Guide.
For information on connecting stacked switches, refer to the
OmniSwitch 6850 Series Hardware Users Guide.

Note. For further details regarding supported SFP and
XFP transceivers, refer to the OmniSwitch Transceivers
Guide.

10

Installing the Hardware

June 2007

Connections and Cabling
Once your switch is properly set up and all the required hardware components are installed, you should connect all network
and management cables required for your network applications. Connections may include:

Serial Connection Default Settings
The default settings for the serial connection are as follows:
baud rate

9600

• RJ-45 cable connection to the console port

parity

none

• Single mode or multimode fiber cables to combo port

data bits (word size)

8

stop bits

1

SFPs as required by your network
• Ethernet cables to 10/100/1000 or 10/100 Ethernet

ports as required by your network

Note. For information on modifying these settings, refer to
the OmniSwitch 6850 Series Hardware Users Guide.

Connecting the Serial Cable
The console port, located on the chassis front panel, provides a
serial connection to the switch and is required when logging
into the switch for the first time. By default, this RJ-45
connector provides a DTE console connection.
Note. For stacked configurations, the serial cable should
be connected to primary management module. If you are
connecting the serial cable to a stack, it is advisable to
wait until the stack has booted and the primary module has
been dynamically assigned. Refer to the OmniSwitch 6850
Series Hardware Users Guide for more information.

June 2007

Connections and Cabling

11

Booting OmniSwitch 6850
Series Switches
Booting a Standalone Switch
The OmniSwitch 6850 Series switch does not use an on/off
switch. The power cord is the switch’s only connect/disconnect device. The power connector socket is located on the
switch’s rear panel. For more information, refer to the
OmniSwitch 6850 Series Hardware Users Guide.

LED States for a Standalone Switch
BPS

Solid amber, if BPS attached is failed;
off, if no operational BPS is attached;
solid green if an operational BPS is
attached and operating normally.

XFP1

Off (applies to all OmniSwitch 6850
Series switches except for the
OmniSwitch 6850-24X,
OmniSwitch 6850-P24X,
OmniSwitch 6850-48X,
OmniSwitch 6850-P48X, and
OmniSwitch 6850-U24X).

XFP2

Off (applies to all OmniSwitch 6850
Series switches except for the
OmniSwitch 6850-24X,
OmniSwitch 6850-P24X,
OmniSwitch 6850-48X,
OmniSwitch 6850-P48X, and
OmniSwitch 6850-U24X).

Slot Indicator

1–8 (non-blinking), depending on the
slot number value in the boot.slot.cfg
file. See the OmniSwitch 6850 Series
Hardware Users Guide for detailed
information. The default value is 1.

To boot the switch, plug the power cord (provided) into the
power connector socket at the switch’s rear panel. Next, plug
the power cord into an easily-accessible power source, such as
a grounded AC outlet or an Uninterruptible Power Supply
(UPS).
The switch immediately begins the boot process. Allow a few
moments for the switch to boot completely, then verify the
status of all LEDs on the switch’s front panel. A successful
boot for a standalone switch displays the following LED
states:
LED States for a Standalone Switch

12

OK

Solid green

PRI

Solid green

PWR

Solid green

Booting OmniSwitch 6850 Series Switches

June 2007

If any of the LED state differs from the states shown in the
table above, refer to the OmniSwitch 6850 Series Hardware
Users Guide for more information. Contact Alcatel-Lucent
Customer Support if the unexpected LED state persists.
For information on booting stacked configurations and
dynamic slot numbering, refer to the OmniSwitch 6850 Series
Hardware Users Guide.

June 2007

Booting OmniSwitch 6850 Series Switches

13

Your First Login Session
Once the switch or stack has successfully booted and you have
accessed your computer’s terminal emulation software via the
console port, you are ready to log in to the switch’s Command
Line Interface (CLI) and configure basic information.
Complete the following steps during your first login session:

Logging in to the Switch
When you first log in to the switch or stack, you will be
prompted for a login (i.e., user) name and password. During
this first login session, only one user name option and one
password option is available:

• Log in to the switch or stack
• Login (i.e., user name)—admin
• Unlock session types
• Password—switch
• Change the login password
• Set the date and time
• Set optional system information
• Save your changes

Note. You must be connected to the switch via the console
port before initiating your first login session. If you are
using OmniSwitch 6850 Series switches in a stacked
configuration, you must be connected to the console port
of the stack’s primary switch.

14

Your First Login Session

To log in to the switch or stack, enter admin at the login
prompt:
login: admin

Next, enter the factory default password, switch, at the password prompt:
password: switch

June 2007

The default welcome banner, which includes information such
as the current software version and system date, displays—
followed by the CLI command prompt:
Welcome to the Alcatel-Lucent OmniSwitch 6850 Series
Software Version 6.1.5.281.R01 Development, March 16, 2007.
Copyright(c), 1994-2007 Alcatel-Lucent All Rights reserved.
OmniSwitch(TM) is a trademark of Alcatel-Lucent registered
in the United States Patent and Trademark Office.
->

More Information on User Accounts. A user account
includes a login name, password, and user privileges.
Privileges determine whether the user has read or write
access to the switch and which commands the user is
authorized to execute.
For detailed information on setting up and modifying user
accounts and user privileges, refer to the “Managing
Switch User Accounts” chapter of your OmniSwitch 6800/
6850/9000 Switch Management Guide.

Assigning an IP Address to the
Switch
Assigning an IP address to your OmniSwitch 6850 Series
switch is an important step in the setup process.
Remote sessions such as Telnet, FTP, and WebView require
an IP address. The IP address for these session types serves as
a destination point for the remote session. Therefore, before
the switch can support any remote login sessions, a valid IP
address must be configured.
To assign an IP address to a switch, simply assign an IP
address to the switch’s default VLAN 1 by entering the
ip interface command at the CLI prompt. Be sure that the
command begins with the command syntax:
-> ip interface address

exactly as shown, followed by the IP address. For example:
-> ip interface vlan_1 address 172.2.120.1
vlan 1

For information on assigning IP addresses in a stacked
configuration, refer to the OmniSwitch 6850 Hardware Users
Guide.

June 2007

Your First Login Session

15

Unlocking Session Types

Unlocking Specified Session Types

Security is a key feature on OmniSwitch 6850 Series switches.
As a result, when you access the switch for the first time, you
must use a direct console port connection. All other session
types (Telnet, FTP, WebView, SNMP, etc.) are “locked out”
until they are manually unlocked by the user.

You can also unlock session types on a one-by-one basis. For
example, to unlock Telnet sessions only, enter the following
command:

The CLI command used to unlock session types is
aaa authentication.

To unlock WebView (HTTP) sessions only, enter the following command:

-> aaa authentication telnet local

-> aaa authentication http local

Note. When you unlock session types, you are granting
switch access to non-local sessions (e.g., Telnet). As a
result, users who know the correct user login and password will have remote access to the switch. For more
information on switch security, refer to the “Managing
Switch User Accounts” chapter of your OmniSwitch 6800/
6850/9000 Switch Management Guide.

You cannot specify more than one session type in a single
command line. However, you can still unlock multiple session
types by using the aaa authentication command in succession. For example:
-> aaa authentication http local
-> aaa authentication telnet local
-> aaa authentication ftp local

Unlocking All Session Types
To unlock all session types, enter the following command
syntax at the CLI prompt:
-> aaa authentication default local

16

Your First Login Session

June 2007

Changing the Login Password
Change the login password for admin user sessions by following the steps below:
1 Be sure that you have logged into the switch as user

type admin (see “Logging in to the Switch” on page 14).
2 Enter the keyword password and press Enter.
3 Enter your new password at the prompt (refer to the

All subsequent login sessions—including those through the
console port—will require the new password in order to access
the switch.
User Accounts. The switch allows a maximum of 50 user
accounts in the local user database. For information on
creating additional user types and assigning individual
passwords, refer to the “Managing Switch User Accounts”
chapter of your OmniSwitch 6800/6850/9000 Switch
Management Guide.

note below).
Note. Typically, the password should be a string of nonrepeating characters. The switch’s authentication software
uses the first occurrence of the character series to uniquely
identify the password. For example, the password
engrengr is the same as engr. A better password might be
engr2735.
4 You will be prompted to re-enter the password. Enter

the password a second time.
Note. Be sure to remember or securely record all new
passwords; overriding configured passwords on
OmniSwitch 6850 Series switches is restricted.
New password settings are automatically saved in real time to
the local user database; the user is not required to enter an
additional command in order to save the password information. Also note that new password information is retained
following a reboot.
June 2007

Your First Login Session

17

Setting the System Time Zone
The switch’s default time zone is UTC (also referred to as
Greenwich Mean Time).
If you require a time zone that is specific to your region—or if
you need to enable Daylight Savings Time (DST) on the
switch—you can configure these settings via the
system timezone and system daylight savings time
commands. For example, to set the system clock to run on
Pacific Standard Time, enter the following command:
-> system timezone pst

To enable Daylight Savings Time, enter the following
command:
-> system daylight savings time enable

Many other time zone variables are supported. For detailed
information on configuring a time zone for the switch, refer to
your OmniSwitch 6800/6850/9000 Switch Management Guide.

Setting the Date and Time
Set the current time for the switch by entering system time,
followed by the current time in hh:mm:ss. For example:
-> system time 18:35:00

The switch uses a 24-hour clock; the time value shown in the
above example would set the time to 6:35 PM.

18

Your First Login Session

To set the current date for the switch, enter system date,
followed by the current date in mm/dd/yyyy. For example:
-> system date 06/27/2005

Setting Optional System
Information
This section provides information on configuring optional
system parameters, including:
• the switch’s administrative contact
• a system name
• the switch’s physical location

Specifying an Administrative Contact
An administrative contact is the person or department in
charge of the switch. If a contact is specified, users can easily
find the appropriate network administrator if they have questions or comments about the switch.
To specify an administrative contact, enter system contact,
followed by a text string of up to 254 characters. If you
include spaces between words in the text string, be sure to
enclose the string in quotes (" ").
For example:
-> system contact "JSmith js@company.com"

June 2007

Specifying a System Name

Viewing and Saving Changes

The system name is a simple, user-defined text description for
the switch.

To view your current changes, enter show system at the CLI
prompt.

To specify a system name, enter system name, followed by a
text description of up to 19 characters.

Once you have configured this basic switch information, save
your changes by entering write memory at the CLI command
prompt.

Note. You cannot include spaces between words when
entering a system name.
For example:
-> system name EngSwitch3

Specifying the Switch’s Location
It is recommended that you use a physical labeling system for
locating and identifying your switch(es). Examples include
placing a sticker or placard with a unique identifier (e.g., the
switch’s default IP address) on each chassis.
However, if no labeling system has been implemented or if
you need to determine a switch’s location from a remote site,
entering a system location can be very useful.
To specify a system location, enter system location, followed
by a text description of up to 254 characters. If you include
spaces between words in the text string, be sure to enclose the
string in quotes (" ").
For example:

When the write memory command is entered, changes are
automatically saved to the main configuration file (boot.cfg)
and placed in the /flash/working directory. For more information on the boot.cfg file, refer to page 20.
Note. If the switch reboots following a write memory
command entry, the switch will run from the
/flash/certified directory. As a result, subsequent configuration changes cannot be saved using the write memory
command until the switch is once again running from the
/flash/working directory. See page 22 for important
information on these directories.

This completes the initial configuration process. Your
OmniSwitch 6850 Series switch is now ready for additional
configuration and network operation. Refer to the following
sections for more information on using your switch, as well as
additional built-in features.
For stacked configurations, be sure to refer to the OmniSwitch
6850 Series Hardware Users Guide.

-> system location "NMS Lab--NE Rack"

June 2007

Your First Login Session

19

Files and Directories
Boot and Image Files

boot.cfg File

Although the flash memory on OmniSwitch 6850 Series
switches can contain many file types (e.g., log and snapshot
files), there are four specific file types that provide key switch
and network functions. These files include the boot.cfg file,
boot.params file, boot.slot.cfg file, and image (.img) files.

The boot.cfg file stores your network configuration parameters. When you first boot the switch, no boot.cfg file is
present. This file is automatically generated when you first
issue a write memory command to save your configuration
changes. The file is then automatically placed in the
/flash/working directory.

boot.params File
The boot.params file provides IP address, gateway, and mask
information for the switch. This information is required for
Ethernet connections to the switch.
This file also contains default console port parameters (baud
rate, etc.) and can be modified via the modify boot
parameters CLI command.
In order to be read by the switch, the boot.params file must be
placed in the /flash directory. If the file is deleted for any
reason, a new boot.params file will be automatically generated on the next system boot. However, all user-configured
information, such as IP address, gateway, and mask information, will be lost. Therefore, it is recommended that you keep a
backup copy of this file at all times.

20

Files and Directories

Important. Your switch must be running from the
/flash/working directory in order to save changes to the
boot.cfg file. Refer to “Working and Certified Directories” on page 22 for more information.

Once the configuration parameters stored in the boot.cfg file
are considered tested and reliable, the file can be copied to the
/flash/certified directory and become part of the “last known
good” software for the switch.
If all copies of this file are deleted and a system boot occurs,
your network configuration will be lost. Therefore, it is recommended that you keep a backup copy of this file at all times.

June 2007

Image Files
Image files (those files with .img extensions) contain an
executable code that provides support for the system, Ethernet
ports, and network functions. In other words, they serve as
essential drivers for switch and network operations.
Although these files may be backed up to the root flash directory or any user-defined subdirectory, they must be present in
the /flash/working and /flash/certified directories for the
switch to operate and pass traffic.
If you delete all copies of an image file, you will be required to
contact Alcatel-Lucent Customer Support for replacements.
Therefore, it is recommended that you keep backup copies on
your computer’s hard drive or a locally-accessible server.

June 2007

For a complete list of OmniSwitch 6850 Series image files,
along with their functions, refer to the following table:
K2os.img

Contains the OmniSwitch 6850
Series operating system software.

Kbase.img

Contains base code for the switch.

Krelease.img

Contains release number information
for the system software package.

Keni.img

Provides support for 10/100/1000
and Gigabit Ethernet.

Kadvrout.img

Alcatel-Lucent’s Advanced Routing
software package. Optional.

Ksecu.img

Provides enhanced security features
for the switch, such as Authenticated
VLANs (AVLANs).

K2diag.img

Provides enhanced hardware
diagnostics for the switch.

Files and Directories

21

Working and Certified
Directories
OmniSwitch 6850 Series switches offer flash memory with
8 MB base ROM space and 64 MB extended ROM. This memory is used to store files, including boot and image files, that
are used for switch operations.
The /flash directory contains two subdirectories: /working and
/certified. These directories work together to provide the
image rollback resiliency feature. Image rollback allows the
switch to return to a prior “last known good” version of software in the event of a system software problem.

Working Directory

Working Directory

Intended for: Files that are being configured
and tested. Once these files are considered
valid and reliable, they can be copied to
the Certified directory.
On reload: If the Working and Certified
directories are identical, the switch will
automatically run from software in this
directory. If the two directories are not
identical, you can instruct the switch to run
from the Working directory by issuing the
reload working command.
Saving changes: You can save configuration changes to the Working directory
via the write memory command.

The /flash/working directory is intended for software that is
still being configured for your network. Changes made while
configuring your switch are saved to the boot.cfg file in the
/flash/working directory.
Once the /flash/working directory’s configuration and image
files are road-tested and considered valid and reliable for your
network, they can be copied to the /flash/certified directory.

22

Files and Directories

June 2007

Certified Directory

Certified Directory

Intended for: Reliable, Tested configuration
and image files. The switch will roll back
to this software in the event of a system
software error.
On reload: By default, the switch will use
the software in this directory if there are
any differences between the Working and
Certified directories.
Saving changes: You cannot save configuration changes to the Certified directory.
To save your changes, be sure that your
switch is operating from the Working
directory.

The software in the /flash/certified directory should be treated
as the “gold master” for the switch. When you place configuration and image files in this directory, you are “certifying”
them as tested and reliable. If the switch is running from the
/flash/working directory and experiences a software problem,
it will “roll back” to the last known good software in the
/flash/certified directory on the next reboot.

How can I tell which directory the switch
is currently using?

When you first boot the switch, the /flash/working directory is
used; this allows you to save your initial configuration changes
to the boot.cfg file. However, subsequent boots may result in
your switch running from the /flash/certified directory. Therefore, verifying the current running directory is a key step any
time you are configuring or monitoring the switch.
View the switch’s current running directory by entering the
show running-directory command. For example:
-> show running-directory
CONFIGURATION STATUS
Running CMM
:
CMM Mode
:
Current CMM Slot
:
Running configuration
:
Certify/Restore Status
:
SYNCHRONIZATION STATUS
Flash Between CMMs
:
Running Configuration
:
Stacks Reload on Takeover:
Activation)

PRIMARY,
DUAL CMMs,
1,
WORKING,
CERTIFY NEEDED
SYNCHRONIZED,
NOT AVAILABLE,
ALL STACKs (SW

In this example, the switch is using the /flash/working directory. For more information on the show running-directory
command output, refer to the “CMM Commands” chapter in
the OmniSwitch CLI Reference Guide.

June 2007

Files and Directories

23

Can I save changes to the Certified directory?

Working and Certified Are Identical

No. The /flash/certified directory is intended to store only
tested, reliable configuration and image files. Configuration
changes must be saved to the boot.cfg file in the
/flash/working directory. Once those changes have been roadtested, the contents of the /flash/working directory can be
copied to the /flash/certified directory via the
copy working certified command.

If the software in the /flash/working and /flash/certified
directories are completely identical, the switch considers the
software in both directories to be equally reliable. In this case,
the switch will run from the /flash/working directory.
Working
Directory

What happens when the switch boots?
During the boot process, the switch compares the contents of
the /flash/working and /flash/certified directories. Based on
this comparison, the switch determines which directory to use
as its running software.

Working and Certified
contents are identical.

boot.cfg
K2base.img
K2release.img
Etc.

Certified
Directory
boot.cfg
K2base.img
K2release.img
Etc.

The switch runs
from Working.

Working
Directory
boot.cfg
K2base.img
K2release.img
Etc.

Certified
Directory
boot.cfg
Hbase.img
Hrelease.img
Etc.

When the switch is running from the /flash/working directory
software, configuration changes can be saved via the
write memory command.

24

Files and Directories

June 2007

Working and Certified Are Different

My Working and Certified directories are different. Can
I force a reboot from the Working directory?

If the software in the /flash/working directory differs even
slightly from the software in the /flash/certified directory, the
switch will automatically run from the /flash/certified
directory.
Working
Directory

Working and Certified
contents are different.

Working
Directory

revised_boot.cfg
K2base.img
K2release.img
Etc.

Certified
Directory
boot.cfg
K2base.img
K2release.img
Etc.

Yes. If its configuration and image files are known to be reliable, you can override the default and initiate a reboot from the
/flash/working directory. This is done via the
reload working command. For more information, refer to
your OmniSwitch CLI Reference Guide.

boot.cfg
Hbase.img
Hrelease.img
Etc.

The switch runs
from Certified.

Certified
Directory
boot.cfg
K2base.img
K2release.img
Etc.

Working
Directory

Working and Certified
contents are different.

revised_boot.cfg
K2base.img
K2release.img
Etc.

Certified
Directory
boot.cfg
K2base.img
K2release.img
Etc.

The reload working
command overrides
the default; the
switch runs from
Working.

Working
Directory
revised_boot.cfg
K2base.img
K2release.img
Etc.

Certified
Directory
boot.cfg
Hbase.img
Hrelease.img
Etc.

When the switch runs from the /flash/certified directory,
configuration changes cannot be saved via the write memory
command.
Note. For detailed information on using directories, refer
to the “Managing CMM Directory Content” chapter in the
OmniSwitch 6800/6850/9000 Switch Management Guide.

June 2007

Files and Directories

25

Using WebView
The switch can be configured and monitored using WebView,
Alcatel-Lucent’s Web-based device management tool.
WebView software is pre-installed in the switch; you are not
required to load additional software.
Note. Although WebView software is pre-installed, you
must first enable HTTP sessions for your switch before
you can log in. Refer to “Unlocking Session Types” on
page 16 for more information.

Logging In to WebView
Note. Before attempting to establish a WebView session,
be sure that you have first unlocked the HTTP session
type via the aaa authentication command. Otherwise, a
login error will occur. See “Unlocking Session Types” on
page 16 for more information.
To access WebView and log in to a switch:
1 Open any Alcatel-Lucent-tested Web browser.

Browser Compatibility
The following Web browsers are recommended for use with
WebView:
• Internet Explorer 6.0 and later for Windows NT, 2000,

XP, 2003
• Netscape 7.1 for Windows NT, 2000, XP
• Netscape 7.0 for Solaris SunOS 5.8

26

Using WebView

June 2007

2 Enter the switch’s IP address in the browser’s

“Address” text field (“Location:” for Netscape users). The
login screen displays.

Navigating WebView
After you have successfully logged in, the Chassis Management home page displays.

3 Enter the user name and password at the login prompt.

Remember, if you have already changed the user name and
password for your switch, be sure to use the new information.
If you have not changed your user name or password, the
factory defaults are admin and switch, respectively. Refer to
the “Managing Switch User Accounts” chapter of your
OmniSwitch 6800/6850/9000 Switch Management Guide for
information on modifying the default user name and password.

June 2007

The Chassis Management home page provides a physical
representation of the switch, as well as basic system information. This is the main launching point for WebView.

Using WebView

27

Navigate the application by clicking on the “Configuration
Group” buttons in the left-hand toolbar.

Refine your navigation by selecting “Configuration Options”
for each group from the items displayed in the grey,
horizontal navigation bar.

“Configuration
Options” Toolbar.
(In this case, the option
“Device” has been selected.)

Main “Configuration
Group” Toolbar.
(In this case, the group
“Health” has been selected.)

Site Maps. WebView also provides site maps for each
configuration group. Site maps allow you to view
complete page contents under each feature. By providing
quick, easy access to specific pages, site maps can reduce
time spent searching through the WebView application.
To access site maps, click the “Site Map” link included on
each configuration group Home page, (e.g., Health).

28

Using WebView

June 2007

Online Help

Additional Information

General online help is available through the main Help link
located in the top WebView banner.

For more information on using WebView, refer to the “Using
WebView” chapter in the OmniSwitch 6800/6850/9000 Switch
Management Guide.

General Help Link

Detailed, context-based help is provided for each status table
and configuration dialog window.

Context-specific Help
button.(In this case, for the
VLAN Administration table.)

June 2007

Using WebView

29

Troubleshooting
The WebView login screen does not display.
This suggests either a physical or network connection issue.
Try the following options:
• Be sure that you have a good physical Ethernet cable

connection to the switch.
• Be sure your computer has a valid Ethernet connection

and IP address.
• Verify that all required WebView image files are

installed in the current running directory. See page 26 for
more information.
The login screen displays, but the login fails.
This suggests either a user name and password or Authenticated Switch Access error. Try the following options:
• Check that you are using the correct user name and

password. If you have already changed the user name and
password for your switch, be sure to use the new information. If you have not changed the user name and password,
the factory defaults are admin and switch, respectively.
• Be sure that you have “unlocked” HTTP sessions on the

switch. To unlock HTTP sessions, enter the following
command:
-> aaa authentication http local

See page 16 for information on unlocking session types.
30

Using WebView

June 2007



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Modify Date                     : 2007:06:04 17:36:09+05:30
Create Date                     : 2007:06:04 15:50:52Z
Subject                         : OmniSwitch 6850 Series
Page Count                      : 34
Creation Date                   : 2007:06:04 15:50:52Z
Mod Date                        : 2007:06:04 17:36:09+05:30
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Alcatel-Lucent
Metadata Date                   : 2007:06:04 17:36:09+05:30
Creator                         : Alcatel-Lucent
Title                           : OmniSwitch 6850 Series Getting Started Guide
Description                     : OmniSwitch 6850 Series
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu