![4-19 Figure 4-9 OC3 Facilities ProvisioningRadio ConfigurationFiber ConfigurationSelect AllSection OH InsertionBER Alarm ThresholdBER Switch Threshold1X10-61X10-64 Fiber SwitchedFrame & B11X10-61X10-61X10-61X10-61X10-61X10-6Alarm DisableOFF OFF OFF OFFService Channel OC3 Facilities WaySide DS1 FacilitiesABTRANSMITTER (IN)ABRECEIVER (OUT)Tuesday, June 3, 2003 5:20:04 AM USI Version R1.04 MDR-8000 OC3 Controller Version R1.4Alcatel User Interface – [Provisioning]File View Setup OptionsF6PerformanceAlarm StatusF4Analog Monitor Station AlarmF7ProvisioningF9User ControlF8F5Prov. SaveF3ELMC Address:ELMC Description:R101OC3 6 GHz TopLOCAL OC3 PROVISIONINGCommunicating***SELECT ERROR RATE (1X10-5, 1x10-6, 1x10-7, OR 1x10-8) AT WHICH RCVR BER ALARM ACTIVATESOR SELECT DISABLE TO DISABLE ALARM.SELECT OFF, TO ENABLE OC3 ALARMS. SELECTON TO DISABLE ALARMS.SELECT ERROR RATE (1x10-5, 1x10-6, 1x10-7, OR 1x10-8) WHICH CAUSES OC3 OUTPUT TO BE SWITCHED OR SELECT DISABLE TO DISABLE OC3 OUTPUT SWITCHING.SELECT ERROR RATE (1x10-5, 1x10-6, 1x10-7, OR 1x10-8) WHICH CAUSES OC3 INPUT TO BE SWITCHED OR SELECT DISABLE TO DISABLE OC3 INPUT SWITCHING.SELECT ERROR RATE (1x10-5, 1x10-6, 1x10-7, OR 1x10-8) AT WHICH XMTR BER ALARM ACTIVATES OR SELECT DISABLE TO DISABLE ALARM.LMW-4026-sm06/03/03SELECT None TO DISABLE SECTION OVERHEAD (OH) DATA INSERT FUNC-TION IN APPLICATIONS WHERE FRAME AND PARITY INSERT IS PERFORMED EXTERNALLY. SELECT Frame TO INSERT SECTION OVERHEAD DATA. SELECT Frame & B1 TO INSERT SECTION OVERHEAD DATA AND PARITY BIT.NoteIf installation at both ends of a hop are complete except for connecting to customer inputs/outputs and it is desirable to have an alarm-free system, alarm reporting on the incomplete connections can be disabled temporarily through provisioning. You can communicate over the hop even if you do not have the radio connected to customer OC3 and wayside DS1 inputs; however, you will alarm. On the OC3 Facilities screen, set Alarm Disable TRANSMITTER (IN) A and/or B and RECEIVER (OUT) A and/or B to ON to disable OC3 alarm reporting for all equipped wayside DS1 lines. After all customer connections are complete, alarm reporting can be restored to normal.](https://usermanual.wiki/Alcatel-USA/8502-8.Complete-Users-Manual-Cont/User-Guide-600069-Page-21.png)




















![4-40 Figure 4-16 DS1/E1, DS3, OC3 Radio ELMC Remote Time-Out Constant Provisioning Remote Time-Out Constants -- MDR-8000Select a value in the following list to change the current remote timeoutOK Cancel3 secs4 secs5 secs6 secs7 secs8 secs9 secs10 secsCurrent time-out is 3 secsAlcatel User Interface - [Alarm Status -- MDR-8000 OC3]File View Setup OptionsREMOTE STATUS ALARMRetrieving ProvisioningELMC Address [F8]:ELMC Description:DURANGOJ7914A BTRANSMITTRANSMITTERSTATUSA BRECEIVERA BCOMMONRECEIVERSTATUSI/OPWRSTATUSF6PerformanceAlarm Status Analog MonitorF5Station AlarmF7ProvisioningF9AcknowledgeF3User ControlF8✓F4LMW-4024A-SM08/08/02SELECT TIME LOCALLY FOR ELMC RESPONSE TO A REQUEST FOR STATUS BEFORE TRYING AGAIN. SELECT SHORTER TIME (5 SECS) FOR SHORTER SYSTEMS (10 HOPS OR LESS). SELECT LONGER TIME (10 SECS) FOR SYSTEMS WITH 10 HOPS OR MORE.MESSAGE DISPLAYED FOR LENGTH OF TIME SELECTED DURING TIME LOCAL RADIO IS ATTEMPTING TO COMMUNICATE WITH REMOTE ADDRESS VIA ELMC.MESSAGE DISPLAYED FOR LENGTH OF TIME SELECTED IF THERE IS NO RESPONSE TO REQUEST FOR STATUS/CONTROL/PROVISIONING.No ReportNoteIf the time-out value selected is too short, there may not be enough time for the remote controller to respond before the requesting controller times out, resulting in a constant No Report. ELMC response time delay is a function of controller circuitry and is not linear. Always start with longer time-out, then reduce time to an acceptable value.](https://usermanual.wiki/Alcatel-USA/8502-8.Complete-Users-Manual-Cont/User-Guide-600069-Page-42.png)

![4-42 Figure 4-18 DS1/E1, DS3, OC3 Radio Alarm Names Provisioning DS3 screen is shown. DS1/E1 and OC3 alarm names provisioning issimilar.Alcatel User Interface – [Provisioning MDR-8000 OC3]File View Setup OptionsUser ControlF8F6PerformanceAlarm StatusF4Station AlarmF7 F9Prov. SaveF3 F5Analog Monitor PasswordF11LOCAL DS3 PROVISIONINGCommunicating***ELMC ADDRESS:ELMC ADDRESS:S302LMW-5068-sm03/29/03ALARM #ALARM NAMES[1]STATION ALARM #2[2]STATION ALARM #3[3]STATION ALARM #4[4]STATION ALARM #5[5]STATION ALARM #6[6]STATION ALARM #7[7]STATION ALARM #8[8]STATION ALARM #9[9]STATION ALARM #10[10]STATION ALARM #11[11]STATION ALARM #12[12]ALARM #ALARM NAMESSTATION ALARM #13 [13]STATION ALARM #14[14]STATION ALARM #15[15]STATION ALARM #16[16]ALARM #ALARM NAMESDS301 -- MDR-8000 DS3DS301 -- MDR-8000 DS3 OK Cancel ApplySTATION ALARM #1Monday, August 6, 2001 2:11:32 PM MDR-8000 DS3 Controller Version R1.032. SELECT ALARM3. BACKSPACE TO DELETE AND TYPE IN NEW ALARM NAME1. SELECT RADIOCLICK HERE TO SAVEAVAILABLE IF RADIO IS PROVISIONED STATION ALARM 13-16 FOR SYSTEM ALARM ON RADIO CONFIGURATION PROVISIONING SCREEN.HIDDEN IF RADIO IS PROVISIONED TBOS DISPLAY 1-8.Note](https://usermanual.wiki/Alcatel-USA/8502-8.Complete-Users-Manual-Cont/User-Guide-600069-Page-44.png)



















































![5-52Figure 5-25 Download Software From PC to Remote Radio ControllerFileAlcatel User InterfaceViewFile SetupStation Alarm User ControlPerformanceAnalog MonitorF7 F8ProvisioningF9F6F6LOCAL MAINELMC Address:Description: Rack-A - bottom radio200R2OptionsF4Alarm StatusCommunicating***200R2COM 1Thursday June 27, 2002 2:16:15 PM USI VersionR1.06 MDR-8000 3DS3 Controller Version R1.05 Double Click on the Elmc to Select ADDRESS:ExitELMC ADDRESS LIST[LOCAL][FAREND]<NEW>200R1 -- Rack A - top radio200R2 -- Rack A - bottom radio201R1 -- Rack B - top radio201R2 -- Rack B - bottom radio202R1 -- Rack C - top radio202R2 -- Rack C - bottom radio203R1 -- Rack D - top radioFileAlcatel User InterfaceViewFile SetupStation Alarm User ControlPerformanceAnalog MonitorF7 F8ProvisioningF9F6F6REMOTE MAINELMC Address:Description: Rack-B - top radio201R2OptionsF4Alarm StatusCommunicating***200R2COM 1Tuesday, June 25, 2002 2:16:15 PM USI VersionR1.06 MDR-8000 3DS3 Controller Version R1.05 Communication OptionsNew ControllerFirmware Upgrade DownloadFileAlcatel User InterfaceViewFile SetupStation Alarm User ControlPerformanceAnalog MonitorF7 F8ProvisioningF9F6F6REMOTE DOWNLOADPlease select a file from the Drive/Directory before DownloadingCommunicating at 38400 BaudELMC Address:Description: Rack-A - bottom radio200R2c:c:\windnldStart DownloadDetailsOptionsF4Alarm StatusCommunicating*40008000 DS38000OC3css11_12.datTuesday, June 25, 2002 11:16:15 PM USI VersionR1.06 MDR-8000 3DS3 Controller Version R1.06 FileAlcatel User InterfaceViewFile SetupStation Alarm User ControlPerformanceAnalog MonitorF7 F8ProvisioningF9F6F6LOCAL DOWNLOADC:\windnld\8000 DS3\css12_16.datCommunicating at 38400 BaudELMC Address:Description: Rack-A - bottom radio200R2c:c:\windnldStart DownloadStop DownloadOptionsF4Alarm StatusCommunicating*8000 DS3css12_12.datcss12_14.datcss12_15.datcss12_16.datTuesday, June 25, 2002 2:16:15 PM USI VersionR1.06 MDR-8000 3DS3 Controller Version R1.05 Alcatel User System InterfaceDownload Successful!OKDOUBLE CLICK TO OPEN ELMC LISTDOUBLE CLICK TO SELECT REMOTE RADIOSELECT OPTIONS/FIRMWARE UPGRADE/DOWNLOADDOUBLE CLICK TO SELECT DIRECTORY AND DISPLAY ALL FILESCLICK ON DIRECTORY AND LATEST FILE (HIGHEST NUMBER)CLICK TO DOWNLOADSTEP123456456321LMW-704607/16/02DownloadStart DownloadAfter automatically re-booting, the controller will start running, provisioning previously stored in the controller will be left unchanged by the download program.Note](https://usermanual.wiki/Alcatel-USA/8502-8.Complete-Users-Manual-Cont/User-Guide-600069-Page-96.png)