Aleis 9060 9060 SERIES ISO RFID READER User Manual 1

Aleis Pty Ltd 9060 SERIES ISO RFID READER Users Manual 1

Contents

Users Manual 1

        Reader  User Guide ISO9161 & ISO9162  Including Aleis DataLink  Version Draft A 18/06/2009  Fixed Race Reader  IMPORTAT! This User Guide must be read  in conjunction with Reader, prior to use.   ©Copyright Aleis Pty Ltd 2009                                                                          13429                              A1064AUS     Aleis  Pty Ltd   PO BOX 63 Jandowae 4410 QLD Australia ACN 130 754 826 www.aleis.com
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 2 of 43
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 3 of 43    9060 Reader Instructions Regularity otices and Conformity ................................................................................................................................ 4Important User Instructions ............................................................................................................................................ 51.0    The Qwerty Keypad................................................................................................................................................. 72.09060 Series Reader Methods of Use ..................................................................................................................... 82.1Record RFID No’s only (no data entry) .............................................................................................................. 82.2Quick Data Entry – One only use of Template ................................................................................................... 82.3 Templates ......................................................................................................................................................... 102.4 Data Entry using Function Keys for a pre made Template .............................................................................. 132.5 How to: Upload RFIDs into the Reader ........................................................................................................... 142.6 How to: Compare RFIDs in the Reader ........................................................................................................... 152.7 Formatting the File System .............................................................................................................................. 162.8 How to Format your reader .............................................................................................................................. 163.09060 Series Menu Tree ........................................................................................................................................ 174.0Audio and Visual alerts ....................................................................................................................................... 185.0Menu ..................................................................................................................................................................... 195.1 Session ............................................................................................................................................................. 195.2Read Setup ........................................................................................................................................................ 205.3 System Setup .................................................................................................................................................... 215.4 Reader Information (This is for technical assistance only & product  identification.) ..................................... 225.5 Memory Status ................................................................................................................................................. 226.0Battery Charging ( ISO9162 only) ..................................................................................................................... 236.1Battery Charging Requirements ........................................................................................................................ 236.2Race Charging using Gel Cell Batteries ............................................................................................................ 236.3Battery Charging Options ................................................................................................................................. 246.4Alternative Recharging Methods ...................................................................................................................... 247.0The Clock ............................................................................................................................................................. 248.0 Using Bluetooth (On ISO9161BT & ISO9162BTmodels only) ........................................................................ 248.1BlueTooth PIN code ......................................................................................................................................... 249.0Aleis DataLink Software ..................................................................................................................................... 259.1Aleis DataLink Installation ............................................................................................................................... 269.2Aleis DataLink Operation ................................................................................................................................. 269.3Aleis DataLink Menu Screen ............................................................................................................................ 279.4Producer Transfer (Australia Only) .................................................................................................................. 289.53rd Party Transfer (Australia Only) ................................................................................................................... 319.6Retrieve Tag Bucket (Australia Only) .............................................................................................................. 349.7Tag Replacement (Australia Only) ................................................................................................................... 369.8NLIS Upload Centre (Australia Only) .............................................................................................................. 3910.0  Rail Measurements for Fixed Race System ....................................................................................................... 4011.0Aleis Conditions of Sale ....................................................................................................................................... 41
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 4 of 43  Regularity otices and Conformity                          USA – FCC  Information to the user (FCC Part 15.105)   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encourage to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna  Increase the separation between the equipment and receiver  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected  Consult the dealer or an experienced radio/TV technician for help  Modification warning (FCC Part 15.21)  Warning:  Any changes or modifications not expressively approved by Aleis could void the user's authority to operate this equipment.   Canada   This Class B digital apparatus complies with Canadian ICES-003.   Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.                        Europe CE   This device has been tested and meets the Electromagnetic Compatibility requirements for EN300 330                       Australia and ew Zealand - C-Tick  This device has been tested and meets the Electromagnetic Compatibility requirements for CISPR 11   Antenna Warning   This device has been designed to operate with the antennas listed below. The ISO9060 Series Readers are only approved with the detachable antennas below. In accordance with RSS-GEN Issue 2 June 2007 Section 7.1.4 and FCC Part 15.21, antennas not included in this list are strictly prohibited for use with this device.        Aleis Part Number  Antenna Size  Antenna Description 4028  1200mm  x 600mm  Loop  antenna  4027  1200mm x 400mm  Loop  antenna 4026  900mm x450mm  Loop  antenna 4025  600mm x 400mm  Loop  antenna 4024  500mm x 400mm  Loop  antenna
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 5 of 43  Important User Instructions   IMPORTAT: Must be read prior to using system The following instructions must be adhered to or permanent damage to the antenna/reader and/or permanent data loss can occur.  Non-conformance to the handling and operating instructions will immediately void all warranties for the antenna/reader and software.     1. Battery must be charged every two months and for maximum performance, batteries need to be charged before and after use.  2. The clock will lose time if the battery is run or left flat. Use DataLink to update your time.  3. Charge for 24 hours for 1st initial charge.  4. Unit is ready to use straight out of the box, (charge battery prior to use) no need to change any settings. If setting are changed unit can be reset to factory defaults. (See Menu tree in this manual).  5.  Cattle must be in single file to be read successfully by the reader  6. WARNING: All Aleis Warranties will be immediately voided if this reader is used in any way with HyperTerminal  7. Up to 1,000 sessions, with maximum of 4,000 RFID numbers per session or 40,000 total records. Data must be cleared at 40,000 total records, or 1000 sessions whatever comes first  8. During transportation, readers must be protected from shock in a padded case or box.  9. Aleis suggests a form of transient protection unit be used while charging the reader to help prevent power surges/spikes  10. Have only one reading system at a time switched on.  11. Do not hose or submerge antenna/reader in water.  12. Use only a very lightly damp cloth to clean antenna/reader.  13. Do not use chemicals to clean antenna/reader.  14. Do not use wand as a prodder or as any form of a cattle motivator.  15. Do not drop reader boxes as electronics are contained within.  16. All boxes with seals are to be kept sealed.  17. Do not remove any VOID stickers from readers.  18. Do not drill holes in antenna.  19. Do not hold or lift system with the hose that runs between the reader and the antenna.  20. Do not have metal objects between reader and RF Link as it will affect range and data may not be transferred and may be lost.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 6 of 43  21. For race systems: The race antenna must be fastened to the wooden panel by four bolts in the holes provided—two in the top of the antenna, and two in the bottom of the antenna.  22. Aleis DataLink is a free single user program for producers to transfer cattle to the LIS database.    23. Aleis Conditions of Sale apply at back of User Guide.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 7 of 43 1.0    The Qwerty Keypad  Data Entry Keys Function Keys Directional Keys Menu Keys
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 8 of 43  2.0  9060 Series Reader Methods of Use  There are four general methods of reading and recording data.  Please read each method and follow  instructions covering the method you choose with your 9060 series system.    2.1 Record RFID o’s only (no data entry)  1.      Turn Reader O.                      (If  a  previous  session  is  still  on  screen  press  F3, go to step 4  below  and  start  a  new               session)  2. Read animal.  3. When finished reading, press F3 and turn reader OFF. Data can be download later at PC, or, start a new session, and read another group of animals.  Start a new session:  1. To start a new session and read another group of animals, press MEU.  2. Select  Session  press OK.  3. ew will be highlighted, press OK.  4. To read next group of cattle same as last group of cattle, press down arrow  and select Blank..  5. Press OK. (ote: A blank data entry box will appear – go to step 9)  6. Press C (located to the left of the MEU button) to return to main reading screen.  7. Proceed to read next group of cattle.    2.2 Quick Data Entry – One only use of Template   Use this method when adding data to RFID’s and not saving template etc. Example: For recording particular data on a rare occasion.   1.   Turn Reader O.  2. Press MEU.  3. Session will be highlighted, press OK.  4. ew will be highlighted, press OK.  5. Press down arrow once to highlight the word Blank.  6. Press OK.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 9 of 43 7. A table heading will appear.  Field  Default Data When setting up template there is no need to have a date field as this will record automatically and print with the report. There are four  data fields available per template.  8. Field column allows for three letters/numbers only for each field.   If recording information for a, tag number, pregnancy result, weight, vaccination, dose rate  or paddock. Abbreviate name to three letters only:  Once name is typed, press down arrow and type in name for  next field.  Field  Default Data TAG   WGT   P/E   PAD    9. Press right arrow to move into second column under Default Data. Default Data is any data that will be the same for every animal read, leave box empty where data is to be changed for each animal. – use  up arrow and down arrow buttons to move in the column.  See the example below.  ote: Make sure down arrow button is pressed after typing is finished in each line – including  the last line.  Field  Default Data TAG  WGT  P/E  PAD  River  10. When finished, press C (located to left of MEU button) to return to session screen.  11. Read first RFID device, press F4.  12. Type in data required – when finished typing first line of data, press OK to move to next line to enter next data.  ote: if data has been entered the same for every animal, it can still be edited if required – on particular line, press Delete or backspace arrow and remove what’s not required and  type data required.  13. Press OK on last field, it will automatically return to main reading screen.  14. Quick guide to using Data Entry Screen when reading cattle:  Field  Default Data Tag  Type in Tag umber, press OK. Vac  5 in 1 - Default Data, press OK. Dos  Type in Dosage, press OK. Pad  River - Default Data, press OK.  Press OK on last field, it will automatically return to main reading screen to read next RFID.  15. When finished reading and recording data press F3, turn Reader OFF and download it later at PC, or start a new session and read another group of animals.  Start a new session: 16. To start a new session to read another group of animals, press MEU.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 10 of 43  17. Session will be highlighted, press OK.  18. ew will be highlighted, press OK.  Follow same instructions from beginning.  If same fields are required, select Same Fields  instead of Blank (as in step 5)  2.3 Templates    Setup New Template  Lock Template  Save Template  Change Template  Remove Template  Setup ew Template  1. Press MEU.  2. Session is highlighted – press OK.  3. Press down arrow once to Data Entry Setup.  4. Press OK.  5. A table heading will appear.    Field  Default Data When setting up template there is no need to have a date field as this will record automatically and print with the report.There are five templates available and four fields available per template.    6. Field column allows for three letters/numbers only for each field.   If recording information for a tag number, pregnancy result, weight, vaccination, dose rate  or paddock. Abbreviate name to three letters only:  Once name is typed, press down arrow and type in name for  next field.  Field  Default Data TAG   WGT   P/E   PAD      7. Press right arrow to move into second column under Default Data. Default Data is any data that will be the same for every animal read, leave box empty where data is to be changed for each animal – use  up arrow and down arrow buttons to move in the column.  See the example below.  ote: Make sure down arrow button is pressed after typing is finished in each line – including  the last line.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 11 of 43 Field  Default Data TAG  WGT  P/E  PAD  River  8. When finished, press C (located to the left of MEU button) to return to the session screen.   Lock Template  9. From Session press down arrow to select Data Entry Locking.  10. Press OK.  11. By pressing OK  in any box locks data to prevent it accidentally being changed when typing data into reader. An X appears in box when locked.   Some Examples:  Field  HDR  DEF  DATA WGT X   TAG X X   P/E X   PAD X X X  Field  TNames created in Data Entry Setup.  HDR   Locks  HDR field so it cannot be accidentally changed when entering data.   (These should always be locked with an X.) This sho DEF      If X is in box, locks default data created in Data Entry Setup. (Default Data is   any data that will be the same for every animal read.)   DATA  Locks data field. When F4 is pressed after reading cattle if this has been locked the data cannot be changed. (This should only be locked with a X if default data is to remain the same for each animal.)  12. Once fields and data are locked to your requirements, press C button to go back one screen.  13. Template needs to be saved if it is to be used at another time.   Save Template  14. Press down arrow  until Templates is highlighted.  15. Press OK.  16. Save Template will be highlighted – press OK.  17. Press OK on first Empty word, or any of the five templates.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 12 of 43 18. Type in template name.  19. When finished press OK.  20. Message appears Template Saved, press OK.  21. Press C three times to return to main reading screen.  22. Reader is ready to read first group of animals.   23. This process can be carried out well before using the reader.   Change Template:  If  template is made, and after using it, it needs to be updated or changed, make a new template as per these instructions, make all the changes, go to Save Template and highlight template being updated.  Press OK, and reader will overwrite (replace) it with new updated template.   Remove Template:   Instead of highlighting the word ‘Empty’ when next template is saved, highlight template to be removed and press OK.     IMPORTAT:   The 9060 Series Reader always remembers the last template used, so if Data Entry Locking has been enabled on last template used, it will need to be unlocked before creating a new template.  To unlock it, go to Data Entry Locking, highlight any box with an X in it, and press the OK.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 13 of 43 2.4 Data Entry using Function Keys for a pre made Template               9060 Series Function Keys  9060 series Function Keys are designed to make entering data into reader simple and quick.  The function of each key is explained to the right of that key, as an example, the F1 key is used to start a new session. These Function Keys are linked directly to created Templates in reader. It is important templates have been set up prior to reading animals and entering data as per this sheet.  1. Turn reader O.  2. Assuming previous session is finished. Press MEU.  3. Session will be highlighted, press OK.  4. Press down arrow until Templates is highlighted.  5. Press OK.  6. Press down arrow until Default Template is highlighted.  7. Press OK.  8. Use arrow keys to highlight (tick) template you want, press OK.  9. Press C four times to return to main reading screen.   10. Press F3 button to end current session.   11. Press F1 to start a new session and enter any data required into Default Data section.   12. Press F2 to start recording.    13. Read first animal  14. Press F4 to enter data against animals (if entering data)  15. Once all required data has been entered, press OK button.  16. When finished reading all animals, press F3 button to finish reading and end session.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 14 of 43    2.5 How to: Upload RFIDs into the Reader  The feature of uploading RFIDs into the 9060 reader is to allow you to find particular RFIDs that you need to identify.  For example, if you need to find a particular animal that was treated with a certain medicinal treatment, you can upload the RFID into the reader.  When you read the animal with that RFID, the reader will alert you with a long series of beeps so that you will know you have found the animal you were looking for.  To use this feature, there are two steps you will need to perform three steps: 1. Create a file to upload into the reader. 2. Upload the RFIDs into the reader. 3. Set the reader up to check each RFID you read against the RFIDs you put into the reader.  Before starting you will need:  1. Aleis DataLink installed on your computer. 2. A working COM port – you can check this by turning your 9060 reader on, and then opening Aleis DataLink.  Down the bottom right corner of the Aleis DataLink screen, you should see that the software has connected to a particular unit. 3. A list of RFIDs that you want to put into the reader.  Step 1: Creating a file to upload into the reader.  Creating the file to upload into the reader is very easy.  You can do this in Microsoft Excel or Wordpad or Notepad.  All you need to do is have a list of RFIDs with the word TAG as the first entry, ie at the top of the list.  It must look like this:  TAG 982 000023661452 982 000016654299 982 000027909419 982 000024909416 982 000009161045 982 000024566253 982 000015883922 982 000030781909  If you are using Microsoft Excel, then simply put this in Column A, with the word TAG in Row 1.  Once you have done this, you will need to save this as a text file (*.txt).  It is very important that you save this as a text file or the operation will not work.  Hint: When you save this, give it a name that is five letters or less.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 15 of 43 Step 2: Upload the files into the reader.  1. Open up Aleis DataLink. 2. Once the software has found the reader, click on the Open button located at the left side of the DataLink screen (there is a big yellow manilla folder on the button). 3. Find the file that you created, and click on the open button. 4. You will see that file name listed in the main screen of Aleis DataLink where the session names and numbers are normally displayed. 5. Click on that file name. 6. Now click on the Upload button located at the left side of the DataLink screen. 7. You will be asked to enter a name.  If you want to change the name, go ahead and type in what you would like, then click on the OK button. 8. When it has been successfully uploaded, you will see at the bottom left of the DataLink screen, the words, “Upload Complete”.  2.6 How to: Compare RFIDs in the Reader  You want to ensure that every time you read an RFID, the reader is checking it against the list of RFIDs you have uploaded into the reader.  To make this happen, do the following:  1. Ensure the reader is turned on. 2. Start a new session – as per your requirements . . . so you will be using a template that you are planning to do your work with. 3. Once you have started the new session, and you are in the main reading screen, press the MENU button. 4. Scroll down to Read Setup and press the OK button. 5. Scroll down to Comparison and press the OK button. 6. Scroll down to  Session (  ) and press the OK button. 7. Scroll back to the name you saved the uploaded file as and press the OK button. 8. Press the C button (located beside the MENU button). 9. The reader will then reboot – now press the MENU button again. 10. Scroll down to Read Setup and press the OK button. 11. Scroll down to Alert and press the OK button. 12. Ensure Condition is highlighted and press the OK button. 13. Scroll down to  On Match and press the OK button – you will see a tick appear in the box. 14. Press the C button (located beside the MENU button). 15. Scroll down to Action and press the OK button. 16. Scroll down to  Msg, LEDs, Buzzer and press the OK button – you will see a tick appear in the box. 17. Press the C button (located beside the MENU button). 18. Scroll down to Duration and press the OK button. 19. Choose the setting you want and press the OK button.  ‘Until Keypress’ means that the reader will continue to beep and flash the LEDs until any key on the reader is pressed. 20. Press the C button (located beside the MENU button). 21. If you want a message to appear as well, scroll down to Message and press the OK button. 22. Type the message you want to appear, then press the OK button. 23. You will see a message that says “Message Saved”.  Press the OK button. 24. Press the C button (located beside the MENU button) three times – until you see the main reading screen. 25. Turn the reader off and then back on. 26. The reader is now ready to use and will compare the RFIDs you read against the list you uploaded.  **Note: When you upload another new list of RFIDs into the reader, in Step 6 of the above, you will need to tick the box  Current Session and then scroll back down and tick the  Session (  ) again to reactivate the reader to search
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 16 of 43 2.7 Formatting the File System  Formatting of the file system is very important to keep your reader operating at its maximum performance. Once the reader has read and stored a lot of tags eg 40000+ you may notice a slow down in its performance when storing and recalling data. This is similar to your PC when the Hard Drive gets full. When you clear the reader it doesn’t actually remove the data so you can retrieve it if you accidentally have cleared the reader. When a “Format file system” is done the data then is lost.    Formatting of the file system should be done every 2-4 months for Heavy users or 4-6 months for light users. Before formatting the file system make sure you have saved any data in the reader. After formatting the data is OT recoverable. When the reader is formatted your templates will also be cleared so note down the names and the fields in the template so you can set them up again.  2.8 How to Format your reader   ote: Read above “Formatting File System in Reader” first  Step 1 Open DataLink  Step 2 Click on “Setup”. Step 3 Click on “Format file system” Step 4 Click on “OK”                                        Step 5 Type in your Name and click on “OK”                                        Step 6 The reader will now be formatting the file system                                  Step 7 Click on the “OK”            Your reader is now formatted.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series           Page 17 of 43    3.0  9060 Series Menu Tree                                           MENU Turn Unit ON Session                       Read Setup          System Setup      Reader Information      Memory Status New  Data Entry Setup  Data Entry Locking  Templates  Send to PC  Clear  Change Name  Select From Template Blank Same Fields Current Session All Sessions  Load/Save Profile  Comparison  Alert  Storage  Send Communications  Display  Buzzer  Sleep Timer  Read Timer  Load Defaults  Set Date/Time Current Session All Sessions Load Profile Save Profile Load DefaultsCurrent Session Sessions (  ) On Read On Match On No-Match No Send On Read On Match On No-Match No Storage Condition Action Duration Message On Read On Match On No-Match No Alert  Msg Msg, LEDs Msg, LEDs, buzzer 2 seconds 5 seconds 10 seconds Until keypress  8030/50 Series  9030/50/60 Series Off On 3 seconds **5 seconds 10 seconds Continuous 5 minutes 15 minutes 30 minutes Disabled Backlight Threshold Backlight Mode LCD Contrast Off On key-press On low-light Always On Interface Protocol Serial Baud Tag Format Scale Interface Tag Filter  SerialRF Modem Bluetooth Tiris Aleis Combined (Tiris/Aleis) Allflex USA 960038400 57600 115200 Notes:  Reader Defaults in Bold text.  ** Handheld units only Read AnimalRead Industrial Read Both ISO 26 Digit ISO 27 Digit 16 Digit No ScalesRuddweigh Thunderbird Tru-Test
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 18 of 43 4.0  Audio and Visual alerts    Features  Buzzer  LCD Display  LEDs at Top of LCD  6 Auxiliary LEDs – 3 each side of the screen Valid READ  One beep  Current RFID number, eg. 971 000000002861, at top of screen READ LED blinks once   Valid READ & ID STORED  Two beeps  Current  RFID  number,  eg. 971 000000002861, at top of screen, and counter at bottom right of screen will increase. READ and STORED LEDs blink once  No ID Read  One long beep                (after read on time out)  NO RFID READ     No RF Signal being received. Two very quick beeps  (every 30 seconds)             (Flashing)     Battery Charge at Low Level  Three very quick beeps (every 60 seconds)    Battery Charge at Critically Low Level  Constant Beeping  BATTERY LOW    Flashes as unit is about to turn off.  Legend for LCD Visual Displays. Battery Level Indicator      BlueTooth                RF Signal Indicator     BT  (Solid)       Connected  BT (Flashing)   Not Fitted       Fully Charged Half Charged No Charge—unit will turn off Signal at Full Strength Signal at 2/3 Strength No Signal—no IDs will be sent. (Flashing)
Aleis ISO9060 Series Operational Manual   Aleis ISO9060 Series     19 of 43 5.0 Menu              Main Menu (Reader selection choices)  5.1 Session ew       New Session  From Template  Blank  Same Fields  Data Entry Setup  - Sets up Data Entry Fields  Data Entry Locking  -  Sets up Data Entry Locking Fields  Templates            Session Template  Save Template  Default Template Send to PC            Send to PC   Current Session  All Sessions Clear            Clear  Current Session  All Sessions  Change ame  - Changes Sessions Name  Select   - Selects Session number and count.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 20 of 43   5.2 Read Setup  Load/Save Profile:  Load Profile   Save Profile  Load defaults – (Resets Read Setup to factory defaults.)  Comparison:  Compare with  Current Session   Session Number – (Select which session number you want    to compare RFID’s with)   Alert  Alert Options Condition Alert Condition  On Read  On Match  On No Match  No alert Action Alert Action:   Msg = Message on screen   Msg,LED’s = Message & Lights  Msg, LED’s, Buzzer = Message, Lights & Buzzer  Duration Duration  2 Seconds  5 Seconds  10 Seconds  Until Keypress  Message – Sets up Message  Storage Store Condition  On Read  On Match  On No-Match  No Alert  Send Send Condition  On Read  On Match  On No-Match  No Send
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 21 of 43 5.3 System Setup Communications Interface Select Interface  Serial  RF Modem  Bluetooth Protocol Select Protocol:  Tiris  Aleis  Combined (Tiris/Aleis)  Allflex USA Serial Baud   9600  38400  57600  115200 Tag Format  ISO 26 Digit  ISO 27 Digit  16 Digit Scale Interface  No Scales  Ruddweigh  Thunderbird  Tru-Test  Display Backlight Threshold (Select required lighting Eg 1 = always bright. 16 = will come on when very dark. Subject to Backlight Mode selection below)       Backlight Mode  Off  On key-press  On low-light  Always On LCD Contrast (Select required contrast Eg 90 = light contrast. 120 = very dark contrast Subject to viewing angle)  Buzzer Buzzer On/Off  On  Off  Sleep Timer   Sleep Timer  5 Minutes  15 Minutes  30 Minutes  Disabled
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 22 of 43 Read Timer  Read Timer  3 Seconds  5 Seconds  10 Seconds  Continuous  Load Defaults  Load Defaults  8030/50 Series  9030/50/60 Series Set Date/Time -Sets Date and Time    5.4 Reader Information (This is for technical assistance only & product  identification.) Reader Info: Hardware:          Hardware Version. Software:            Software Version. Date:                   Software Date Serial o:           Reader Serial Number. Reader Type:     Aleis Reader Model.       5.5 Memory Status    Used Memory X%    Percentage of Used Memory    Free Memory X%  Percentage of Free Memory    Reclaimable Memory X% Percentage of Recoverable Cleared Memory         (old Sessions)
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 23 of 43  6.0  Battery Charging ( ISO9162 only)  The batteries in the unit should only be charged by using the 9-pin connector on the side of the unit.   6.1 Battery Charging Requirements  • Charge unit using supplied charger only.  • Aleis suggests a form of transient protection unit be used while charging the reader to help prevent power surges/spikes.  • Do not use Reader while it is being charged.  • Ensure when fitting charger connector that the male and female grooves are aligned and pushed in correctly.  • For Race units Battery is not to be run dead flat. Unit must be charged prior to storage and every 4-6 weeks to maintain battery life.  .   6.2  Race Charging using Gel Cell Batteries  • To ensure that the battery receives a full charge, charge the unit overnight (Min 8hrs).  • To verify that the unit is charging, turn unit on and the battery icon will fill up, i.e. the icon will turn black, as the batteries are charged.  • Readers can be left on charge – once the reader batteries have been charged, the charger will then automatically convert to trickle charge and no damage will be done to the batteries. (A transient protector is recommended to help prevent spikes through the power line damaging the charger and reader. Aleis part number 4059)  • The battery does not have to be flat to be charged.  It is recommended that after each use, the unit is charged.  • Charge the battery prior to use and every 4-6 weeks. If the unit is not used for a long period of time, recharge unit overnight prior to use.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series  Page 24 of 43 6.3  Battery Charging Options  An optional Car Cigarette Lighter Battery Charger is available.  6.4 Alternative Recharging Methods  Contact Aleis for alternative methods of charging.   7.0 The Clock  The clock on the 9060 Reader is what will put the date and time stamp on each RFID that is read by the reader.  To reset or change the date and time on the clock, simply plug the 9060 Reader into your computer, turn the reader on, and then open Aleis DataLink. (This is the default setting in DataLink Setup). After 30 seconds, the reader will automatically be updated with the date and time that is on your computer.  Please ensure the date and time on your computer is correct. This feature can be disabled in the DataLink setup menu by unticking the box.  You can also change the clock in the Menu through System Setup.  OTE: The clock will lose time if the battery is run or left flat.         8.0   Using Bluetooth (On ISO9161BT & ISO9162BTmodels only)  The Bluetooth is turned on via the menu. Eg. Menu/System Setup/Communications/Interface/Bluetooth  The BT symbol will appear solid if a Bluetooth is fitted. If it flashes a Bluetooth is not fitted.   Notes: 1. The Bluetooth Feature is only available if you have a ISO9161BT or ISO9162BT model. If you don’t your unit can be upgraded for this feature. Contact the supplier for further information and costing.   2. Bluetooth is a way you can communicate to a PC, PDA or other device without using the serial cable, referred to as a Wireless connection.   3. The PC or device that the reader is going to communicate to must have Bluetooth fitted. The PC or device sets up the link between the two units.  8.1  BlueTooth PI code  The Pin Code or access code as it is sometimes referred to is the  serial number on the side of the Reader.  If the sticker is missing, when you discover the Reader on the PC or device, the 4 number which comes up in the name of the reader discovered, is the pin number.  Refer to your PC or other devices manual to see how to discover and connect to a BlueTooth device
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 25 of 43 Aleis DataLink Software  9.0  Aleis DataLink Software   IMPORTAT Must be read prior to using software   This software has been purposefully designed to download the RFID’s and/or respective data relating to those RFID’s from the Aleis 7000 8030/50 and 9030/50/60 Series Readers.  Aleis accepts no responsibility for any form of improper use, negligent or otherwise, resulting in the loss of RFID’s with the use of this software.  All practical assistance will be given in the operation and understanding of this software, and this can be obtained by contacting Aleis or an Aleis distributor.  Copying of this software is strictly prohibited.  1. This software is designed for Aleis 7000 8030/50 and 9030/50/60 Series Readers ONLY.  2. Aleis Reader must be plugged into computer this software is installed on.  3. Aleis Reader must be turned ON before opening Aleis DataLink.  4. Aleis DataLink PC Requirements:   Operating Systems  • Windows ME  • Windows NT 4.0  • Windows 2000  • Windows XP (Recommended)  • Vista Minimum Hardware • Pentium 233 MHz (Recommended: Pentium 500MHz or greater)  • 64 MB RAM (Recommended: 128 MB RAM or greater)  • 20 MB hard drive space      This software package serves as an easy download program which automatically downloads the reader’s session list. Once the reader is downloaded, you can then save particular downloaded sessions or all downloaded sessions on your computer.  You can then open these saved files in Excel or your desired program.  The program also allows you to Transfer animals on the NLIS database.    Special features include:  • Auto-detects what com-port  reader is plugged into. • Quick and easy animal transfers to the NLIS database for Producers and 3rd party users.  • Downloading all animal data from reader to excel. • Loading tag file buckets from database to the reader. • Updating Readers software. • Updates clock on reader to time displayed on computer. (For models that have clocks.)
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 26 of 43  9.1  Aleis DataLink Installation    To install DataLink:  1. Place the DataLink CD into the CD drive; the program will automatically begin    installation.       If not Go to My Computer Double click on the CD Rom Drive Browse the CD and       Double click on the icon called DataLink  2. Follow the installation prompts, and click on Finish when installation is complete.   9.2  Aleis DataLink Operation    Operating Aleis DataLink:  IMPORTAT:  The Aleis Reader must be plugged securely into your computer and turned on before opening Aleis DataLink.     1.0  Plugging the Aleis Reader into your computer.  Plug the 9 pin female serial connector into the 9 Pin male serial connection at the back of your computer or laptop.  Some laptops do not have a serial connection, and so a Serial to USB adaptor can be used.  Should such an adaptor be used, Aleis DataLink works just as effectively provided you have installed the drivers for the adaptor correctly.    2.0  Opening Aleis DataLink.       1.  Turn Aleis Reader on  2  Double click on the Aleis DataLink icon located on your desktop.  3.  This will open up the software for operation.  As soon as the program is opened, it   will automatically download the reader for you.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 27 of 43   9.3  Aleis DataLink Menu Screen      Full Index for Help in software (F1)                                       Brief overview of Aleis DataLink Menu Screen       Show Sessions- Displays lists of sessions when you select old or current Current- Displays current session  Old- Displays sessions previously cleared from reader  Re-downloads session out of reader   Open: Opens sessions previously saved on computer Save As: Saves sessions to file of choice on computer  Clears all sessions from reader  Clears selected session from reader  Uploads selected session to reader   Setup  1: Update reader software, 2: Format file systems, 3: Advanced features  Remote Connect only used in multiple reader situations  Gives the ability to enter RFID numbers or NLIS numbers manually in the event of tag failure.  Prints selected information  Exports session to Excel  Exits DataLink     Below are a list of options used for transferring information and retrieving information from the LIS database (Australia Only)  Used for producers to transfer livestock to the NLIS database  Used for third party to transfer livestock to the NLIS database  Retrieves all NLIS numbers recorded to individual PIC from NLIS database  Used for replacing non reading identification tags  History of all transfers to NLIS Database  Gives a full index of all help functions
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 28 of 43    9.4  Producer Transfer (Australia Only) This opens the NLIS Transfer Wizard, using the selected fields in the current session(s). This button is used for Producer to Producer transfers.                                                                                                                          For further information please use the help feature in Aleis DataLink.    Producer Transfer Steps  Step 1 Click on the "Producer Transfer" button.                         You will be presented with the following Box       Step 2 Click on "Yes" if you are sure you have selected the correct session and                                      unticked any tags not to be transferred.   You will then be presented with the following Box
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 29 of 43       Step 3 After completing the form Click on "Next"  If you choose to tick the Upload Later box the Transfer will not be completed but you can complete the transfer at any time by resuming the upload from the Upload Centre.  The PIC From PIC To and Vendor Dec/Waybill No. can be loaded straight into the form if the fields PI1, PI2 and VEN were used as Data entry on Data entry readers.   You will then be presented with the following Box
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 30 of 43       Step 4 Click on the "Start" box  On a successful or unsuccessful transfer you will get a message in the status box.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 31 of 43    9.5 3rd Party Transfer (Australia Only)   This opens the NLIS Transfer Wizard, using the selected fields in the current session(s). This button is used for Third Party transfers with or without written permission.                                                                                   For further information please use the help feature in Aleis DataLink   3rd Party Transfer Steps  Step 1 Click on the "3rd Party Transfer" button.                          You will be presented with the following Box    Step 2 Click on "Yes" if you are sure you have selected the correct session and                                      unticked any tags not to be transferred.   You will then be presented with the following Box
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 32 of 43   Step 3 After completing the form Click on "Next"  If you choose to tick the Upload Later box the Transfer will not be completed but you can complete the transfer at any time by resuming the upload from the Upload Centre. The PIC From PIC To and Vendor Dec/Waybill No. can be loaded straight into the form if the fields PI1, PI2 and VEN were used as Data entry on Data entry readers.   You will then be presented with the following Box
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 33 of 43 Step 4  Click on "Yes" You have to accept this agreement to finish the transaction  You will then be presented with the following Box        Step 5 Click on the "Start" Box  On a successful or unsuccessful transfer you will get a message in the status box.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 34 of 43 9.6  Retrieve Tag Bucket (Australia Only)  This opens the NLIS Transfer Wizard, to retrieve all RFID and NLIS ID tag numbers that match a specific PIC from the NLIS database. You can also retrieve the Lifetime Traceability (LT), EU Status (EU), Last Transfer Date (TFR) and the Issue Date (ISS)                                                                                                        For further information please use the help feature in Aleis DataLink   Retrieve Tag Bucket Steps  Step 1 Click on the "Retrieve Tag Bucket" button.                             You will then be presented with the following Box
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 35 of 43  Step 2 After completing the form Click on "Next"  You will then be presented with the following Box       Step 3 Click on "Start"  The Tag Bucket will be loaded into the main screen of DataLink.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 36 of 43 9.7  Tag Replacement (Australia Only)  This opens the NLIS Tag Replacement Request form using the selected tags in the current session. This button is used for replacing defective RFID tags.                                                                                                                      For further information please use the help feature in Aleis DataLink    Tag Replacement Steps  Step 1 Click on the "Tag Replacement" button.                          You will be presented with the following Box     If there are any tags in the current session you are given the option to load them into the Replacement tag box.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 37 of 43     Step 2 Type in the Replacement tag and the Broken tag in the boxes below        Step 3 Click on the "Add Request" Box and the tags will be inserted into the box below.      Step 4 Click on the "Send All" or "Send Selected" button (it can only send the selected tags if required)
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 38 of 43 You will be presented with the following Box     Step 5 After completing the form Click on "Next"  You will be presented with the following Box    Step 6 Click on "Start"  On a successful or unsuccessful tag replacement you will get a message in the status box
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 39 of 43  9.8  LIS Upload Centre (Australia Only)  This opens the Upload Centre screen, which displays all transactions with the NLIS database. Both successful and unsuccessful transactions are displayed and information regarding the transaction.                                         For further information please use the help feature in Aleis DataLink
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 40 of 43 10.0    Rail Measurements for Fixed Race System                                                    Antenna Mounting Measurements Bottom of Antenna to be mounted 300 mm from ground where animal actually stands. Antenna bolt hole spacings are marked on diagram above.  Holes are pre-drilled in antenna. DO NOT DRILL HOLES IN ANTENNA YOURSELF.       10.10.01
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 41 of 43 11.0  Aleis Conditions of Sale In these conditions:   (1) `Vendor' means Aleis Pty Ltd ACN 130 754 826 of the Cnr Old Rosevale & Jandowae/Kingaroy Rds, Jandowae, Queensland, 4410  which is the seller of the goods    (2) ‘Factory’ means the Vendor’s principal place of business at the Cnr Old Rosevale & Jandowae /Kingaroy Rds, Jandowae, Queensland  4410.   (3) Purchaser' means the customer(s) described overleaf which is the purchaser of the goods.  (4) `Goods' means the products and, if any, services specified overleaf  (5) Nothing in these conditions shall be read or applied so as to exclude, restrict or modify or have the effect of excluding, restricting or modifying any condition, warranty, guarantee, right or remedy implied by law (including the Trade Practices Act 1974) and which by law cannot be excluded, restricted or modified.  (6) Words denoting the singular number only include the plural number and vice versa; where reference to any gender includes every other gender and words denoting individuals include corporations  1. These conditions (which shall only be waived in writing signed by the vendor) shall prevail over all conditions of the purchaser's order to the extent of any inconsistency.  3.  The goods and all other products sold by vendor are sold on these terms and conditions.  4.  Unless previously withdrawn, vendor's quotation is open for acceptance within the period stated therein or, when no period is so stated, within thirty (30) days only after its date. The vendor reserves the right to refuse any order based on this quotation within 7 days after the receipt of the order.  5.  The cost of any special packing and packing materials used in relation to the goods shall be at the purchaser's expense notwithstanding that such cost may have been omitted from any quotation.  6.  The purchaser waives any claim for shortage or discrepancy of any goods delivered if a claim in respect thereof has not been lodged with vendor within seven (7) days from the date of receipt of goods by the purchaser.  7.  All specifications, drawings, and particulars of weights and dimensions submitted by vendor are approximate only and any deviation shall not be taken to vitiate any contract with vendor or form grounds for any claim against vendor. The descriptions, illustrations and performances contained in catalogues, price lists and other advertising matter do not form part of the contract of sale of the goods. Where specifications, drawings or other particulars are supplied by purchaser, vendor's price is made on estimates of quantities required. Should there be any adjustments in quantities above or below the quantities estimated by vendor and set out in a quotation, then any such increase or decrease shall be adjusted on a unit rate basis according to unit prices set out herein.  8.1  Any performance figures given by vendor are estimates only. Vendor shall be under no liability for damages for failure to attain such figures unless specifically guaranteed in writing and any such written guarantee shall be subject to the recognised tolerances applicable to such figures.  8.2  The Purchaser acknowledges that frequency from other products, for example computer equipment, videos, loud speakers and other metal products may affect the goods’ performance.  The Vendor gives no warranty that in the event of any frequency disruption the goods will remain fit for the purpose intended.  The Vendor will not be liable for any claims made as a result of other equipment or other things interfering with the performance of the goods whether on account of frequency disruption or otherwise.  9.  Delivery dates mentioned are an estimate only and vendor shall not be liable for late delivery or non-delivery and under no circumstances shall the vendor be liable for any loss, damage or delay occasioned to the purchaser arising from late or non-delivery or late installation of the goods.  10.  (1)  Unless specifically agreed otherwise in writing, delivery shall be ex-factory. The Purchaser must make its own arrangements for the transport of the goods from the factory and any assistance that the Vendor gives in transporting the goods shall not effect the rights of the Vendor under this Clause. Vendor is not responsible for any loss or damage to goods in transit.  (2)  Risk in the goods shall pass to the Purchaser upon dispatch of goods from Factory.  11.  (1)  Vendor's liability for goods manufactured by it is limited to making good any defects by repairing the same or at vendor's option by replacement, within a period not exceeding twelve calendar months after the goods have been dispatched (or installed by Aleis) provided that:      (a)  defects have arisen solely from faulty materials or workmanship;      (b)  the goods have not received maltreatment, inattention or interference;      (c)  accessories of any kind used by the purchaser are manufactured by or approved by vendor;      (d)  the seals of any kind on the goods remain unbroken; and  (e) the defective parts are promptly returned free of cost to vendor.  (f) all freight is paid by the purchaser.    (2)  If goods are not manufactured by vendor the guarantee of the manufacturer thereof shall be accepted by the purchaser and is the only guarantee given to purchaser in respect of the goods.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 42 of 43   (3)  Vendor shall not be liable for and purchaser releases vendor from any claims in respect of faulty or defective design of any goods supplied unless such design has been wholly prepared by vendor and the responsibility for any claim has been specifically accepted by vendor in writing and in any event vendor's liability hereunder shall be strictly limited to the replacement of defective parts in accordance with para 11(1) of these conditions.  (4) Except as provided herein, all express and implied warranties, guarantees and conditions under statute or general law as to merchantability, description, quality, suitability or fitness of the goods for any purpose or as to design, assembly, installation, materials or workmanship or otherwise are hereby expressly excluded and vendor shall not be liable for physical or financial injury, loss or damage or for consequential loss or damage of any kind arising out of the supply, layout, assembly, installation or operation of the goods or arising out of vendor's negligence or in any way whatsoever.  12.  Vendor's liability for a breach of a condition or warranty implied by Div 2 of Pt V of the Trade Practices Act 1974 (other than s 69) is hereby limited to:   (1)  in the case of goods, any one or  more of the following:  (a) the replacement of the goods or the supply of equivalent goods;      (b)  the repair of the goods;      (c)  the payment of the cost of replacing the goods or of acquiring equivalent goods;  (d)  the payment of the cost of having the goods repaired; or  (2)  in the case of services:      (a)  the supplying of the services again; or      (b)  the payment of the cost of having the services supplied again.  13.  Vendor's liability under s 74H of the Trade Practices Act 1975 is expressly limited to a liability to pay to the purchaser an amount equal to:    (1)  the cost of replacing the goods;    (2)  the cost of obtaining equivalent goods; or    (3)  the cost of having the goods repaired, whichever is the lowest amount.  14.  Unless otherwise stated all prices quoted by vendor are net, exclusive of tax. Prices quoted are those ruling at the date of issue of quotation and are based on rates of freight, insurance, customs duties, exchange, shipping expenses, sorting and stacking charges, cartage, rate of weighs, cost of materials and other charges affecting the cost of production ruling on the date the quotation is made and any alterations thereto either before acceptance of or during the currency of the contract shall be to the purchaser's account.  15   The purchase price in relation to goods shall be payable and payment or balance thereof shall be made immediately at time of order, or otherwise as agreed in writing.  16.  Vendor reserves the following rights in relation to the goods until all accounts owed by the purchaser to vendor are fully paid:    (1)  legal ownership of the goods;    (2)  to enter the purchaser's premises (or the premises of any associated company or agent where the goods are located) without liability for trespass or any resulting damage and retake possession of the goods; and    (3)  to keep or resell any goods repossessed pursuant to (2) above;  If the goods are resold, or products manufactured using the goods are sold, by the purchaser, the purchaser shall hold such part of the proceeds of any such sale as represents the invoice price of the goods sold or used in the manufacture of the goods sold in a separate identifiable account as the beneficial property of vendor and shall pay such amount to vendor upon request. Notwithstanding the provisions above vendor shall be entitled to maintain an action against the purchaser for the purchase price and the risk of the goods shall pass to the purchaser upon delivery.  17.  Any property of the purchaser under vendor's custody or control shall be entirely at the purchaser's risk as regards loss or damage caused to the property or by it.  18.  Vendor reserves the right to make a reasonable charge for storage if the purchaser does not take delivery of goods within fourteen days of notification that the goods are ready for collection.  19.  Vendor shall not be under any obligation to accept goods returned by the purchaser and will do so only on terms to be agreed in writing in each individual case.  20.  All goods to be supplied by vendor shall be as described on the quotation overleaf and the description on such order modified as so agreed shall prevail over all other descriptions including any purchaser's specification or inquiry.  21.  No order may be cancelled except with consent in writing and on terms which will indemnify vendors against all losses.  22.  The contract for sale of the goods is made in the state of Queensland and the parties agree to submit all disputes arising between them to the courts of such state at any court competent to hear appeals therefrom.  23. The Purchaser shall pay all and any import duties, levies or imports and/or any sales, use, excise, gross receipts, value added, goods and services tax, property or other taxes or duties of any kind whatsoever assessed upon or relating in any way to the goods ordered by the Purchaser irrespective of the person, nation, state or authority requiring payment thereof.
Aleis ISO9060 Series Operational Manual  Aleis ISO9060 Series Page 43 of 43  24.  If the Vendor has not paid for any goods on the due date specified in this Agreement, without prejudice to any other right or remedy, all outstanding money shall bear interest on daily balances until paid at the rate of 1.5% per month and such money together with all interest shall be recoverable forthwith from the Purchaser.  The Purchaser charges as a fixed charge with the payment of all monies now or in the future becoming owing hereunder all his property both real and personal (other than property referred to in Section 262 (i) of the Corporations Law) and as a separate charge charges all his other property with the payment of all monies now or in the future becoming owing hereunder, provided that this second charge will be a floating charge in respect of the Purchaser’s current assets but otherwise will be a fixed charge.  The Purchaser irrevocably makes, nominates, constitutes and appoints, and in the place and stead of the Purchaser puts and deputes the Vendor and (if the Vendor is a corporation) the directors, general manager and secretary for the time being of the Vendor jointing and each of them severally to be the Attorney or Attorneys of Purchaser at any time after default as aforesaid has been made (sufficient proof of which will be the Statutory Declaration of the Attorney or Attorneys or either or any of them) to do all such things as may be required to consent to any Caveat or other like instrument under the Real Property Legislation of any other jurisdiction in the form prepared by the Vendor’s Solicitor over any or all of the Purchaser’s property and to execute a mortgage and/or charge or other like instrument under the Real Property Legislation of any other jurisdiction in such form and containing such terms and conditions as the Vendor may require over any or all of the Purchaser’s property and from time to time to appoint a substitute or substitutes and such appointment or appointments at pleasure to revoke and another or other substitute or substitutes to appoint and generally to do, execute and perform any act, deed, matter or thing for that purpose as fully and effectually as the Purchaser could do and the Purchaser agrees to ratify and confirm all and whatever the said Attorney or Attorneys or any substitute or substitutes lawfully do or cause to be done for that purpose.                            The End   Ver10/05/01