POCKET READER“ AND
POCKET-READER EX”
vzsr sesame usxne
Operator’s Manual
FCC Statement
POCKET (EX) READER
Destron Fearing
South St. Paul MN 55075-2443
1-800-328-0118
FCC ID: WMQRE60l6
Industry Canada Registration lD
IC: 4284-RE6016
This device complies with Part 15 of the FCC rules,
Operation is subject to the following conditions, (1) This device
may not cause harmful interference, and (2) this device must
accept any interference received including interference that may
cause undesired operation.
This equipment shall not be modified or changed without the
approval of Destron Fearing Corporation.
CONTENTS
Scanner Function Index ............................ 2
I. BA'ITERIES
Installation ................ 3
For Best Results
RecommendedBatteries H 4
Optional AC/DC Power Adapter
EX Model only ............................... 4
Automatic Shut Off Feature
Low Power ............................... 4-5
II. SCANNER OPERATION
To Activate Scanner ............................ . . , 5
To Scan ......................................... 6
Scanning Area .....................
Injection Sites ..................................... 7
Locating an Implanted Microchip ”H... , . . . . . . . . . . . . . 8
Scanning Patterns for Implants
lnjectedMid—scapula...,v.,.,._......s_. ..... 8
Scanning Patterns for implants
Injected at the left side of the neck . _ .
TurningtneScannerOffu....i..i....._..i.....v.
To Extend Battery Life .......................... . v . 9
Field Programmable Ports ........................... 9
Resetting the System ................ .4.._. . . . . IO-II
III. SPECIFICATIONS
Phi/ciral and Electronic Characteristics .................. IO
LCD
DISPLAY
SCAN
BUTTON
ACIDC POWER PORT
FIELD PROGRAMMABLE PORT
The 134 2 kHz Pocket Reader and Pocket Reader EX comply wwth ISO ”785.
HOW TO USE THE POCKET READER"n
AND THE POCKET READER EX“
I. BATTERIES
Installing/Replacing the Batteries for the
Pocket Reader
Remove the door to the battery
compartment by loosening the retention
screw located on the underside of the
reader Slide 4 AAA alkaline batteries into
battery slom. Note proper battery
direction. Replace compartment door
and firmly tighten retention screw.
The Pocket Reader uses
4 AM alkaline batteries
Installing/Replacing the Batteries for the
Pocket Reader EX
The Pocket Reader EX uses
4 AA alkaline batteries
Remove the door to the battery
compartment by inserting a coin in
the slot at the bottom of the
batten/ door and loosening the
retention clip located on the
underside of the scanner. Remove
the battery door and slide 4 AA
alkaline batteries into the battery
sloB. Note proper battery
direction. Replace the
compartment door and firmly press
the retention clip into place.
FOR BEST RESULTS: We recommend using Duracell® or
Energizer? alkaline batteries to operate the Pocket Reader and
Pocket Reader EX. Rechargeable batteries will not
provide sufficient power to operate the scanners.
in some cases, when new batteries are installed, they will
cause the scanner to indicate ”LOW BATTERIES”. Turn the unit
on and off three to four times and the low battery display
should disappear
IMPORTANT: lf the scanner stops or ”freezes" part way
through its program, reset the program by completely removing
the batteries, relnstalling them and following the instructions for
Installing/Replacing the Batteries.
Optional ACIDC Power Adapter
The Pocket Reader E>< is capable of being powered directly from
a standard wall outlet. To utilize this function, plug the power
adapter into the wall outlet and place the output plug into the
scanner AC/DC socket while the scanner is off. The scanner
will now run directly off of the power supplied from the wall
outlet. Optional Power Adapter available for Pocket Reader EX
models only.
(Optional adapter available for the EX Model onlyl
Warning
Do not plug the AC/DC power adapter into the Pocket Reader EX
while the scanner is under power. Turn the scanner off and
then insert the power plug into the power socket. Failure to follow
this procedure may result in damage to the Pocket Reader EX.
Automatic Shut Off Feature
The scanners are equipped with an Automatic Shut Off feature,
When the battery power level drops to a point that the energy
is not sufficient to read an implanted micmdvip, the scanner will
automatically shut off. The Pocket Reader and Pocket Reader EX
will display LOW BATTERY (Figure I), followed by REPLACE
BATTERY (Figure 2)t The scanner WI” remain inoperable until
a new set of batteries is installed.
my sfFunE usma 1»; 55:3“ usING
LOW BATTERY 1 WE BATTERY
POCKET-READER EX" roast-READER EX”
ll. SCANNER OPERATION
To Activate Scanner
Push the button down once and release. in 2—3 seconds the
unit will display the software version, then the unit will display
READY (Figure 3),
,.—-—
1m max: unus
READY
POCKET-READER Ex"
,__-—
multi‘m
Searching for Implanted Microchips
To Scan
Push the button down and hold. The unit will display
WORKlNG,
— 1
res? mans usmrs l
WDR Kl NG
FucKEr-READER EX”
Test Before Scanning an Animal
it is important to test the unit before scanning an animal. Use
the test chip provided with each scanner to verify that the
scanner is functioning properly. While holding the button clown,
pass the microchip under the scanning area located at the
upper backside of the reader Verify an accurate scan
was achieved before continuing. if the scanner does
not read the test chip, refer to the installing/Replacing Batteries
section in this manual or contact your distributor
Scanning Area
The units scan for identification codes from the backside.
CAUTION: Computer terminals and video screens in
operation, metal collars, leads, chains or tags within 3 meters
(or approximately lO feet) of the microchip can reduce the read
range of the scanner. if possible, turn these devices off, remove
the metallic objects, or move farther away from the devices or
objects until you are finished reading microchips.
Injection Sites
Subcutaneous, midescapula Subcutaneous, upper half of the
left side of the neck, halfway from
me ear to the tip of the shoulder.
Australla New Zealand
Canada United Kingdom
Japan Unlted States European Contlhent
NOTE: The Pocket Reader and Pocket Reader EX can ldehtlfy
the presence of other manufacturers‘ mlcrochlps, However, not
all mlcrochlps have the patented BloBondE anti-migration cap.
Therefore, It is important to Increase the normal suggested scan
area by scannmg the animal down to the elbows and m from of
the shoulders as illustrated below:
Locating an Implanted Microchip
To lecate an implanted microchip, push the scan button and
hold until scanner displays WORKiNG. While continuing to
push the scan button, place the scanner flush
with the under de flat touching the animal over
the injection site. Move the scanner slowly, in a Circular
motion, following the scanning patterns below. (NOTE: injection
site may vary with species of animal, brand of microchip and
country where the animal was microchipped, See injection Sites
for locations.) When a microchip is located, you will hear a
beep, followed by the code being displayed on the LCD window.
I if the scanner shows a numeric or alpha code display
{numbers and/or letters) on the LCD window during the
WORKiNG phase of the scanning procedure, it is an
indication of the presence of a microchip.
Scanning Patterns for implants injected
mid-scapula.
IMPORTANT
Microchip placement may vary per animal.
I Scan slowly With a small,
circular motion
l Scan both patterns as
indicated
I Keep scanner
touching animal
Q 32 ‘
I Hold down
button during
entire scan
Scanning Patterns for implants injected at the
left side of neck.
IMPORTANT
Microchip pizamerit may vary per animal
I 531 siuwly with a small,
ciimlair motion
l 531 both panems as
inflamed
I Keep Kanner
(aiming animal
I lied down
Main during
attire sca n
Turning the Scanner off
To turn the unit off when NO lD FOUMD is displayed, release the
button and the scanner will shutoff automatically in 5 seconds
To turn the unit off when a microchip code is displayed, release
the button and scanner unit wrll automatically shut off after 70
seconds of display.
To extend battery life: After a microchip code is displayed,
push the button once and release. The scanner will clear the
code and display WORKlNG, followed oy NO lD FOUND The
unit will then automatically shut off in 5 seconds.
Field Programmable Port
The scanners have the ability to be programmed to read future
generations of microchips by using the programmable port.
Resetting the System: IMPORTANT
Under some unusual circumstances, the scanner may display
uncommon characteristics indicated by:
I a straight solid line across the LCD
l a lit, but blank LCD
I the unit not powering off
Resetting the System: continued
These characteristics can normally be corrected by resetting the
scanner. To reset the scanner, temporarily disconnect the
batteries or external power supply.
III. SPECIFICATIONS
Physical and Electronic Characteristics
fig‘aet Reade
Operating Temperature:
Smnge Temperature:
Humidity:
Batteries:
Dis-play:
Outpin Port:
RS 232 Port:
Cnmpafible z Compatible
l Avoid storing unit in direct sunlight, excessive moisture or
extreme temperatures.
I The Pocket Reader and Pocket Reader EX scanners are
designed specifically for use with companion animals in a
veterinary clinic or animal shelter environment
BioBond‘ is a registered trademark and Pocket Readerw and Pocket Reader EXW are
trademarks of the Demon-Fearing Corporation.
Duracell is a registered trademark of Duracell inc and Energizer is a registered
trademark of the Eveready Battery Co., Inc.
lO

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 12
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WMQRE6016

Navigation menu