Allflex USA RE6016 Handheld Pet ID Scanner User Manual manual
Destron Fearing Corporation Handheld Pet ID Scanner manual
manual
POCKET READER“ AND POCKET-READER EX” vzsr sesame usxne Operator’s Manual FCC Statement POCKET (EX) READER Destron Fearing South St. Paul MN 55075-2443 1-800-328-0118 FCC ID: WMQRE60l6 Industry Canada Registration lD IC: 4284-RE6016 This device complies with Part 15 of the FCC rules, Operation is subject to the following conditions, (1) This device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. This equipment shall not be modified or changed without the approval of Destron Fearing Corporation. CONTENTS Scanner Function Index ............................ 2 I. BA'ITERIES Installation ................ 3 For Best Results RecommendedBatteries H 4 Optional AC/DC Power Adapter EX Model only ............................... 4 Automatic Shut Off Feature Low Power ............................... 4-5 II. SCANNER OPERATION To Activate Scanner ............................ . . , 5 To Scan ......................................... 6 Scanning Area ..................... Injection Sites ..................................... 7 Locating an Implanted Microchip ”H... , . . . . . . . . . . . . . 8 Scanning Patterns for Implants lnjectedMid—scapula...,v.,.,._......s_. ..... 8 Scanning Patterns for implants Injected at the left side of the neck . _ . TurningtneScannerOffu....i..i....._..i.....v. To Extend Battery Life .......................... . v . 9 Field Programmable Ports ........................... 9 Resetting the System ................ .4.._. . . . . IO-II III. SPECIFICATIONS Phi/ciral and Electronic Characteristics .................. IO LCD DISPLAY SCAN BUTTON ACIDC POWER PORT FIELD PROGRAMMABLE PORT The 134 2 kHz Pocket Reader and Pocket Reader EX comply wwth ISO ”785. HOW TO USE THE POCKET READER"n AND THE POCKET READER EX“ I. BATTERIES Installing/Replacing the Batteries for the Pocket Reader Remove the door to the battery compartment by loosening the retention screw located on the underside of the reader Slide 4 AAA alkaline batteries into battery slom. Note proper battery direction. Replace compartment door and firmly tighten retention screw. The Pocket Reader uses 4 AM alkaline batteries Installing/Replacing the Batteries for the Pocket Reader EX The Pocket Reader EX uses 4 AA alkaline batteries Remove the door to the battery compartment by inserting a coin in the slot at the bottom of the batten/ door and loosening the retention clip located on the underside of the scanner. Remove the battery door and slide 4 AA alkaline batteries into the battery sloB. Note proper battery direction. Replace the compartment door and firmly press the retention clip into place. FOR BEST RESULTS: We recommend using Duracell® or Energizer? alkaline batteries to operate the Pocket Reader and Pocket Reader EX. Rechargeable batteries will not provide sufficient power to operate the scanners. in some cases, when new batteries are installed, they will cause the scanner to indicate ”LOW BATTERIES”. Turn the unit on and off three to four times and the low battery display should disappear IMPORTANT: lf the scanner stops or ”freezes" part way through its program, reset the program by completely removing the batteries, relnstalling them and following the instructions for Installing/Replacing the Batteries. Optional ACIDC Power Adapter The Pocket Reader E>< is capable of being powered directly from a standard wall outlet. To utilize this function, plug the power adapter into the wall outlet and place the output plug into the scanner AC/DC socket while the scanner is off. The scanner will now run directly off of the power supplied from the wall outlet. Optional Power Adapter available for Pocket Reader EX models only. (Optional adapter available for the EX Model onlyl Warning Do not plug the AC/DC power adapter into the Pocket Reader EX while the scanner is under power. Turn the scanner off and then insert the power plug into the power socket. Failure to follow this procedure may result in damage to the Pocket Reader EX. Automatic Shut Off Feature The scanners are equipped with an Automatic Shut Off feature, When the battery power level drops to a point that the energy is not sufficient to read an implanted micmdvip, the scanner will automatically shut off. The Pocket Reader and Pocket Reader EX will display LOW BATTERY (Figure I), followed by REPLACE BATTERY (Figure 2)t The scanner WI” remain inoperable until a new set of batteries is installed. my sfFunE usma 1»; 55:3“ usING LOW BATTERY 1 WE BATTERY POCKET-READER EX" roast-READER EX” ll. SCANNER OPERATION To Activate Scanner Push the button down once and release. in 2—3 seconds the unit will display the software version, then the unit will display READY (Figure 3), ,.—-— 1m max: unus READY POCKET-READER Ex" ,__-— multi‘m Searching for Implanted Microchips To Scan Push the button down and hold. The unit will display WORKlNG, — 1 res? mans usmrs l WDR Kl NG FucKEr-READER EX” Test Before Scanning an Animal it is important to test the unit before scanning an animal. Use the test chip provided with each scanner to verify that the scanner is functioning properly. While holding the button clown, pass the microchip under the scanning area located at the upper backside of the reader Verify an accurate scan was achieved before continuing. if the scanner does not read the test chip, refer to the installing/Replacing Batteries section in this manual or contact your distributor Scanning Area The units scan for identification codes from the backside. CAUTION: Computer terminals and video screens in operation, metal collars, leads, chains or tags within 3 meters (or approximately lO feet) of the microchip can reduce the read range of the scanner. if possible, turn these devices off, remove the metallic objects, or move farther away from the devices or objects until you are finished reading microchips. Injection Sites Subcutaneous, midescapula Subcutaneous, upper half of the left side of the neck, halfway from me ear to the tip of the shoulder. Australla New Zealand Canada United Kingdom Japan Unlted States European Contlhent NOTE: The Pocket Reader and Pocket Reader EX can ldehtlfy the presence of other manufacturers‘ mlcrochlps, However, not all mlcrochlps have the patented BloBondE anti-migration cap. Therefore, It is important to Increase the normal suggested scan area by scannmg the animal down to the elbows and m from of the shoulders as illustrated below: Locating an Implanted Microchip To lecate an implanted microchip, push the scan button and hold until scanner displays WORKiNG. While continuing to push the scan button, place the scanner flush with the under de flat touching the animal over the injection site. Move the scanner slowly, in a Circular motion, following the scanning patterns below. (NOTE: injection site may vary with species of animal, brand of microchip and country where the animal was microchipped, See injection Sites for locations.) When a microchip is located, you will hear a beep, followed by the code being displayed on the LCD window. I if the scanner shows a numeric or alpha code display {numbers and/or letters) on the LCD window during the WORKiNG phase of the scanning procedure, it is an indication of the presence of a microchip. Scanning Patterns for implants injected mid-scapula. IMPORTANT Microchip placement may vary per animal. I Scan slowly With a small, circular motion l Scan both patterns as indicated I Keep scanner touching animal Q 32 ‘ I Hold down button during entire scan Scanning Patterns for implants injected at the left side of neck. IMPORTANT Microchip pizamerit may vary per animal I 531 siuwly with a small, ciimlair motion l 531 both panems as inflamed I Keep Kanner (aiming animal I lied down Main during attire sca n Turning the Scanner off To turn the unit off when NO lD FOUMD is displayed, release the button and the scanner will shutoff automatically in 5 seconds To turn the unit off when a microchip code is displayed, release the button and scanner unit wrll automatically shut off after 70 seconds of display. To extend battery life: After a microchip code is displayed, push the button once and release. The scanner will clear the code and display WORKlNG, followed oy NO lD FOUND The unit will then automatically shut off in 5 seconds. Field Programmable Port The scanners have the ability to be programmed to read future generations of microchips by using the programmable port. Resetting the System: IMPORTANT Under some unusual circumstances, the scanner may display uncommon characteristics indicated by: I a straight solid line across the LCD l a lit, but blank LCD I the unit not powering off Resetting the System: continued These characteristics can normally be corrected by resetting the scanner. To reset the scanner, temporarily disconnect the batteries or external power supply. III. SPECIFICATIONS Physical and Electronic Characteristics fig‘aet Reade Operating Temperature: Smnge Temperature: Humidity: Batteries: Dis-play: Outpin Port: RS 232 Port: Cnmpafible z Compatible l Avoid storing unit in direct sunlight, excessive moisture or extreme temperatures. I The Pocket Reader and Pocket Reader EX scanners are designed specifically for use with companion animals in a veterinary clinic or animal shelter environment BioBond‘ is a registered trademark and Pocket Readerw and Pocket Reader EXW are trademarks of the Demon-Fearing Corporation. Duracell is a registered trademark of Duracell inc and Energizer is a registered trademark of the Eveready Battery Co., Inc. lO
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 12EXIF Metadata provided by EXIF.tools