Allterco Robotics SSWTHLIM MyKi Care - Thermometer User Manual MCT 1 0

Allterco Robotics MyKi Care - Thermometer MCT 1 0

User Manual

Download: Allterco Robotics SSWTHLIM MyKi Care - Thermometer User Manual MCT 1 0
Mirror Download [FCC.gov]Allterco Robotics SSWTHLIM MyKi Care - Thermometer User Manual MCT 1 0
Document ID3814123
Application IDAR/FFLwmUgGOUBe5wk3rjQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize26.23kB (327862 bits)
Date Submitted2018-04-12 00:00:00
Date Available2018-04-12 00:00:00
Creation Date2018-04-09 16:01:02
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2018-04-09 16:01:02
Document TitleMicrosoft Word - MCT 1.0_User Manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

MyKi Care Thermometer (MCT 1.0)
Precautions for use
Any form of modification to this device is
forbidden;
Don’t use the device together with MRI or
CT equipment;
Explosion danger: don’t use the device in
flammable anesthetic gas;
Don’t squeeze the device. If the housing is
broken, please stop using the device.
Please check device regularly to make
sure that it makes contact with skin tightly;
otherwise the data may be inaccurate.
The device is for indoor use only;
Please pay attention to the operation
temperature and humidity. Using the
thermometer in a condition that does not
satisfy the requirement may lead to
measurement error;
The effective wireless transmission
distance is 10m in a barrier‐free
environment. The thermometer may not
work if attempting to use at greater
distances. Please use this product within
effective wireless transmission distance;
Muscle and fat affect wireless
transmission, so the transmission range
Allterco Robotics LTD. 1404 Sofia, Bulgaria
may be weakened when obese adult or
child uses the device.
Magnetic and electrical fields are capable
of interfering with the proper performance
of the thermometer. For this reason make
sure that all external equipment operated
in the vicinity of the thermometer
complies with the relevant EMC
requirement. Mobile phone, X‐ray
equipment or MRI devices are a possible
source of interference as they may emit
higher levels of electromagnetic radiation.
The thermometer is not sterile;
Doctor should diagnose clinical symptoms,
only with using the thermometer as
subsidiary;
This product has been calibrated. No
other routine maintenance and calibration
is needed in addition to the replacement
battery;
If the system upgrade, please update the
program;
It is very unlikely that the thermometer is
not compatible with the mobile app on
your mobile device. Please contact us if
you experience this problem;
If you have questions concerning setting
up, using, maintenance of the
phone +35929571247
USER MANUAL
thermometer or any unexpected events,
please contact MyKi Care support at:
support@myki.care
When the patient is the operator, please
use and maintain the thermometer
according to this manual.
We recommend the users to use the
original manufactured adhesive pads. To
get best reading on thermometer use in a
cool environment. If you feel unwell
(uncomfortable or allergic) when using the
adhesive pad, please discard and stop
using adhesive pad and follow doctor’s
advice.
When measuring for a long time, please
check whether there an allergic reaction
with skin. If there is an allergic reaction,
you should stop using the thermometer
immediately.
Please do not re‐paste the adhesive pad if
it appears used, A new adhesive pad is
required.
Skin preparation in advance is required
when worn by adult. Please make sure
that skin is clean and dry.
Please clean the surface of the
thermometer with 75% concentrated
medical alcohol before and after using it.
You should clean the skin contacted the
www.MyKi.Caresupport@myki.care
MyKi Care Thermometer (MCT 1.0)
thermometer with medicinal alcohol after
taking off the device. The material that
contacts skin is nontoxic, nonirritating and
will not cause allergy or any other side
effect.
One may experience an allergic reaction
or possible other side effect If pets or
pests touch the device. Please clean the
surface of the device with 75%
concentrated medical alcohol before using
it.
If children tamper or play with the device,
this may damage the temperature
measuring probe and affect the measure
accuracy.
The thermometer starts up when you
shake it intensive during 3 seconds. When
is strart the red light is blinking 5 times. If
you shake it during the work the red light
is blink for 3 times. Thermometer shuts
down automatically when the
temperature is under 35 degree and not
shacked for 5 min.
The thermometer sends temperature to
the device every 8‐12 seconds.
This product has overrun prompted
function, and users can set the alarm limit
themselves. This device complies with Part
15 of the FCC Rules. Operation is subject
Allterco Robotics LTD. 1404 Sofia, Bulgaria
USER MANUAL
to the following two conditions: (1) This
device may not cause harmful interference;
(2) This device must accept any
interference received, including
interference that may cause undesired
operation. The user is cautioned that
changes or modifications not expressly
approved by the party responsible for
compliance could void the user's authority
to operate the equipment FCC
STATEMENT:
following measures: ‐‐ Reorient or relocate
the receiving antenna. ‐‐ Increase the
separation between the equipment and
receiver. ‐‐ Connect the equipment into an
outlet on a circuit different from that to
which the receiver is connected. ‐‐ Consult
the dealer or an experienced radio/TV
technician for help.
This equipment has been tested and
found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference in a residential
installation. This equipment generates,
uses and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may
cause harmful interference to radio
communications. However, there is no
guarantee that interference will not occur
in a particular installation.
The device is intended to be used for
measuring and monitoring human
temperature continuously. It can store and
manage the temperature data. It can be
used to measure armpit temperature for
the adult, pediatric and neonate people.
The device is not waterproof and cannot
used to measure liquid temperature.
If this equipment does cause harmful
interference to radio or television
reception, which can be determined by
turning the equipment off and on, the user
is encouraged to try to correct the
interference by one or more of the
phone +35929571247
Intended Use
Download And Install The Software
The Thermometer is compatible with iOS
7+ and Android 5+ devices. To use it open
the Appstore for iOS or Google Play for
Android and download the application
MyKi Care.
Operation Instructions
1. Open MyKi Care application and
create account.
www.MyKi.Caresupport@myki.care
MyKi Care Thermometer (MCT 1.0)
USER MANUAL
2. Login in your account and input
patient data.
6. Put the adhesive pad carefully. If
you need to re‐place change the
adhesive pad.
4. Press on the ID of the
Thermometer
3. Shake the Thermometer for 3
seconds, during the red light start
blinking for 5 seconds.
Allterco Robotics LTD. 1404 Sofia, Bulgaria
5. Place the Thermometer under the
arm with metal part to the body.
phone +35929571247
Change adhesive pad every 2 hours
during the day and 6‐8 hours during the
night.
www.MyKi.Caresupport@myki.care
MyKi Care Thermometer (MCT 1.0)
USER MANUAL
Thermometer need 12‐15 min to
measure and show the body
temperature.
You can use thermometer for multiple
patients in one application. To add new
patient just slide left to right and follow
the screen instruction.
You can watch the thermometer data
from unlimited devices at same time. For
that, all devices should share same
account.
Only one of all devices should be up to 10
meters to the thermometer. All data
automatically upload to the cloud and all
other devices can see whenever they are.
You should to have internet connection to
all devices.
Set correct alarm setting base of your
requirements.
The alarm maybe not work if you your
mobile phone do not have internet,
notifications is forbidden, your device is in
DND mode or notification services is
temporary inaccessible.
Allterco Robotics LTD. 1404 Sofia, Bulgaria
phone +35929571247
www.MyKi.Caresupport@myki.care
MyKi Care Thermometer (MCT 1.0)
Possible problems and solutions:
Product specifications:
Product name:
Product model:
Weight without
battery:
Measure
specifications
Measure scope
Measure accuracy
Temperature unit
Update time
Light
Software platform
iOS
Android
Battery
Type
Work time
Environment
specifications
Temperature
Humidity
Atmospheric
pressure
USER MANUAL
Symptom
Device not wake‐up
when I shake it. Red
light do not appear.
MyKi Care Thermometer
MCT 1.0
34.00Ԩ~45.00Ԩ(93.00Ԭ~113.00Ԭ)
+/‐ 0.1 C (0.18 F)
C or F
Every 8‐12 seconds
Blining when shaked
7+ version
5+ version
CR2025, 3V/163mAH button battery
7 days / 8h per day
Operating: 5℃~+45℃;
Transportation and storage: ‐20Ԩ~+55Ԩ.
Operating: 25%~95%(non condensing)
Transportation and storage: 25% ~ 95%
(non condensing)
Operating: 700hPa~1060hPa;
Transportation and storage:
500hPa~1060hPa.
Allterco Robotics LTD. 1404 Sofia, Bulgaria
phone +35929571247
Solution
Check the battery. Carefully open the device
and replace the battery with new one.
Check the device position. Must be under arm
Temperature is not
with metal cap connected to the body. Replace
correct after 20 min
the adhestive pad.
For children mobile phone should me under
10meter from the thermometer. For
Thermometer do not
adults,mobile phone should be under 2 meters
connect to the mobile
to the thermometer.
device
Check – are your Bluetooth is activated.
Cannot remember mu
Create new account and add themormter to it
account details.
or contact with: support@myki.care
Guidance and manufacture’s declaration of EMC
The device is intended for use in the electromagnetic environment
specified below. The customer of the user of the device should
assure that it is used in such an environment.
Emission test
RF emissions CISPR 11
RF emission CISPR 11
Compliance
Group 1
Class B
Harmonic emissions IEC 61000‐3‐2
Not applicable (Battery
operated device)
Voltage fluctuations/ flicker
emissions IEC 61000‐3‐3
SAR
Not applicable (Battery
operated device)
…………….
www.MyKi.Caresupport@myki.care
MyKi Care Thermometer (MCT 1.0)
USER MANUAL
Operation Frequency:
Bluetooth: 2402-2480MHz, 40 channels for BLE
Max. RF output power: Bluetooth: -0.70dBm
Hardware Version: MT01CY
Software Version: FW-MT01
Environmental Conditions:
Working Temperature: 5 ~ 45℃ Working humidity: 25~95%RH
Bluetooth can be used in Europe without restriction.
Hereby, Allterco Robotics, declares that this MyKi Care - Thermometer /
MCT 1.0 is In compliance with the essential Requirements and other
relevant provisions of RE Directive 2014/53/EU.
Allterco Robotics LTD. 1404 Sofia, Bulgaria
phone +35929571247
www.MyKi.Caresupport@myki.care

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Administrator
Create Date                     : 2018:04:09 16:01:02+08:00
Modify Date                     : 2018:04:09 16:01:02+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Format                          : application/pdf
Title                           : Microsoft Word - MCT 1.0_User Manual
Creator                         : Administrator
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:1f2eab7b-0581-48b5-848d-7f6602e87503
Instance ID                     : uuid:10142684-d1f5-467f-8267-89db5444dab1
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ALAY-SSWTHLIM

Navigation menu