Alula RE301 Security Transmitter, 433.92MHz User Manual RE301 DSC Compat DWS Instructions
Resolution Products, Inc. Security Transmitter, 433.92MHz RE301 DSC Compat DWS Instructions
  
    Alula   >  
User Manual

RE301_DSC-Compat_DWS_Instructions.doc 
Page 1 of 3  7/22/2011 
www.ResolutionProducts.com 
Wireless  
Security  
Solutions 
RE301 DSC-Compatible Standard Door / Window 
Features  
• For sensing things that open or separate. 
• 3 total zones.  Each with separate ESNs. 
o Main reed switch + magnet 
o 2 supplemental hardwire zones  
 Outer terminal. 
 Inner terminal. 
• Cover tamper. 
• Strong, reliable RF signal. 
• 10-15 year battery life on CR123A battery. 
• Low Battery indication. 
Key Instructions 
• Battery “+” faces towards spring. 
• DWS has 3 zones with 3 ESNs.  But when it comes from the factory, only 
the magnetic reed switch reports to the panel.  The other two external 
contact zones must be “activated” in order to report. 
• External contact zones are: normally closed – alarm on open. 
• No end-of-line resistors on external contact zones.   
• Activating Zones – ACTIVATE ONLY THE ZONES YOU NEED: 
 Reed switch Zone 0: 
 ESN ends in “0” and is labeled on the DWS battery bucket. 
 Comes from factory already activated. 
 External Contact Zone 1: 
 Outer terminal + Center Terminal 
 ESN is same as Reed switch, except it ends in “1” 
 Activate by shorting Zone 1 while installing battery. 
 External Contact Zone 2: 
 Inner terminal + Center Terminal 
 ESN is same as Reed switch, except it ends in “2” 
 Activate by shorting Zone 2 while installing battery. 
• Enrolling Zones in DSC Panel:   
 Put panel in Wireless Enrollment Mode. 
 Set all active zones on the DWS to NON-Alarm state. 
 Open (alarm) only the zone on the DWS that you want to enroll. 
 Confirm ESN, Enter Zone # and Zone Type on DSC Panel. 
 May also be enrolled via entering ESN. 
RE301_DSC-Compat_DWS_Instructions.doc 
Page 2 of 3  7/22/2011 
www.ResolutionProducts.com 
Operation  
• Magnetic reed switch (ESN “0”): 
Alarm, when magnet is pulled away from reed switch. 
• External Contact zones (Outer=ESN “1”, Inner=ESN “2”) 
Each zone functions ONLY if Activated AND Enrolled in panel. 
Alarm: when contact opens. 
Zones function independently and send separate ESN signals. 
• Tamper reports on each and every active zone, when cover is opened. 
• Supervisory signals sent for each and every active zone, every hour. 
Specifications   
Magnet trip distance:  1 inch nominal 
Mounting hardware:  # 4 or #6 screws 
Replacement Battery:  CR123A 1550mAH 
Temperature Range:  0F to 120F 
Housing dimensions:  3.3x1.4x1.1 inches 
Specifications subject to change without notice. 
Internal Picture 
ESN ending in “1”
Outer Terminal Zone 
Activated by loop being 
shorted during power-up 
Center Common Terminal 
ESN ending in “2”
Inner Terminal Zone 
Activated by loop being 
shorted during power-up 
ESN ending in “0”
Magnetic Reed Switch 
Comes from factory active 
Tamper

RE301_DSC-Compat_DWS_Instructions.doc 
Page 3 of 3  7/22/2011 
www.ResolutionProducts.com 
Notices 
“GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell 
International Inc., and Tyco Safety Products Canada LTD, respectively.   
Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell 
systems.  However, no Resolution product is produced by, endorsed by, nor is officially 
associated with GE, Honeywell or DSC.   Resolution recommends verifying proper enrollment 
and operation, per control panel installation instructions, at installation. 
Warranty 
Resolution Products, Inc. will replace products that are defective in their first year. 
FCC Notice 
This device complies with Part 15 of the FCC rules.  Operation is subject to the 
following two conditions: 
This device may not cause harmful interference. 
This device must accept any interference that may be received, including 
interference that may cause undesired operation. 
Changes or modifications not expressly approved by the Resolution Products, Inc. could 
void the user's authority to operate this equipment. 
FCC ID: U5X-RE301 
IC Notice 
This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions: 
1. This device may not cause interference, and  
2. This device must accept any interference, including interference that may 
cause undesired operation of the device. 
Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. 
Son fonctionnement est soumis aux deux conditions suivantes: 
1. Ce dispositif ne peut causer des interférences, et 
2. Ce dispositif doit accepter toute interférence, y compris les interférences 
qui peuvent causer un mauvais fonctionnement du dispositif. 
IC: 8310A-RE301