Alvarion Technologies EXTR-CPE-49H WiMAX subscriber unit transceiver User Manual BreezeMAX PRO 5000 CPE

Alvarion Technologies Ltd. WiMAX subscriber unit transceiver BreezeMAX PRO 5000 CPE

Users Manual

Download: Alvarion Technologies EXTR-CPE-49H WiMAX subscriber unit transceiver User Manual BreezeMAX PRO 5000 CPE
Mirror Download [FCC.gov]Alvarion Technologies EXTR-CPE-49H WiMAX subscriber unit transceiver User Manual BreezeMAX PRO 5000 CPE
Document ID1304626
Application IDRNvv6zhFld4+o2rPNf8yIg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize108.74kB (1359277 bits)
Date Submitted2010-07-01 00:00:00
Date Available2010-07-01 00:00:00
Creation Date2017-11-09 00:56:04
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-11-09 00:56:04
Document TitleBreezeMAX PRO 5000 CPE.book
Document CreatorFrameMaker 8.0
Document Author: Alvarion LTD.

BreezeMAX® PRO 5000 CPE
Product Manual
Software Version 1.5
April 2010
P/N 215643
Document History
Doc um e nt H ist or y
Topic
Description
Date Issued
First Release
New Product Manual
SW Version 4.6, 
July 2009
Ethernet CS display
Updated the Service Parameters page
SW Version x.x,
September 2009
New IDU power supply unit
XTRM-SU-IDU-1D
Added specifications and information
SW Version 1.2, 
October 2009
“Service Parameters” on
page 79
Removed the Modify option
SW Version 1.2, 
October 2009
“User Registration” on
page 60
Added EAP-AKA to the screen
SW Version 1.2, 
October 2009
“Radio Parameters” on
page 67
Added “ATPC Parameters” on page 72
SW Version 1.2, 
October 2009
“User Registration” on
page 60
Added default username and password.
SW Version 1.5, 
January 2010
“ATPC Parameters” on
page 72
 Added a note that the DHCP Client can
SW Version 1.5, 
January 2010
be set to disable only in ETH-CS service.
 The upload procedure of a country codes
file (country_codes.xml) was added: The
country codes file can be uploaded to the
CPE using the Configuration Control
menu.
 A new field was added to the Show
parameters: Current Country Code Data
 Country codes changed
SW Version 1.5, 
January 2010
“Unit Control Parameters” on
page 47
Added a new page: “Licences” on
DHCP Client Configuration page
Moved the DHCP Client Configuration page
from Radio Parameters to Management
Parameters.
SW Version 1.5, 
January 2010
“Parameters Summary” on
page 85
Updated latest parameters: Registration
default username and password, Licences
and AM&TM
SW Version 1.5, 
January 2010
General
 Added information on models with
SW Version 1.5, 
March 2010
page 56
external antennas.
 Replaced all screenshots
BreezeMAX PRO 5000 CPE
ii
Product Manual
Document History
Topic
Description
Date Issued
5 GHz Integral Antenna in
15°AZ x 15°EL instead of 20°
SW Version 1.5, 
March 2010
 Allocation of IP parameters: Removed
SW Version 1.5, 
March 2010
Table 1-1
Table 1-5
LAN-Configurable, added options 66, 67
 Configuration Upload/Download: added
TFTP
 Authentication: Removed TLS
TM/PM Files Control
Removed
SW Version 1.5, 
March 2010
“Aligning the PRO CPE’s
External Antenna” on page 39
New section
SW Version 1.5, 
March 2010
Integratiion Time
Removed
SW Version 1.5, 
March 2010
“Configuration Control” on
page 53
New functions
SW Version 1.5, 
March 2010
“Licences” on page 56
New section
SW Version 1.5, 
March 2010
“User Registration” on
page 60
Revised
SW Version 1.5, 
March 2010
“BST/AU Parameters” on
page 63
Revised
SW Version 1.5, 
March 2010
Added section “Country Codes” on
SW Version 1.5, 
March 2010
“ATPC” on page 73
page 73
BreezeMAX PRO 5000 CPE
iii
Product Manual
Legal Rights
Le ga l Right s
© Copyright 2010 Alvarion Ltd. All rights reserved.
The material contained herein is proprietary, privileged, and confidential and
owned by Alvarion or its third party licensors. No disclosure thereof shall be made
to third parties without the express written permission of Alvarion Ltd.
Alvarion Ltd. reserves the right to alter the equipment specifications and
descriptions in this publication without prior notice. No part of this publication
shall be deemed to be part of any contract or warranty unless specifically
incorporated by reference into such contract or warranty.
Tra de N a m e s
Alvarion®, BreezeCOM®, WALKair®, WALKnet®, BreezeNET®, BreezeACCESS®,
BreezeLINK®, BreezeMAX®, BreezeLITE®, BreezePHONE®, 4Motion®,
BreezeCONFIG™ and/or other products and/or services referenced here in are
either registered trademarks, trademarks or service marks of Alvarion Ltd.
All other names are or may be the trademarks of their respective owners.
“WiMAX Forum” is a registered trademark of the WiMAX Forum. “WiMAX,” the
WiMAX Forum logo, “WiMAX Forum Certified,” and the WiMAX Forum Certified
logo are trademarks of the WiMAX Forum.
St at e m e nt of Condit ions
The information contained in this manual is subject to change without notice.
Alvarion Ltd. shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or use of
this manual or equipment supplied with it.
Wa rra nt ie s a nd Discla im e rs
All Alvarion Ltd. ("Alvarion") products purchased from Alvarion or through any of
Alvarion's authorized resellers are subject to the following warranty and product
liability terms and conditions.
Exclusive Wa r ra nt y
(a) Alvarion warrants that the Product hardware it supplies and the tangible
media on which any software is installed, under normal use and conditions, will
be free from significant defects in materials and workmanship for a period of
fourteen (14) months from the date of shipment of a given Product to Purchaser
(the "Warranty Period"). Alvarion will, at its sole option and as Purchaser's sole
remedy, repair or replace any defective Product in accordance with Alvarion'
standard R&R procedure.
BreezeMAX PRO 5000 CPE
iv
Product Manual
Legal Rights
(b) With respect to the Firmware, Alvarion warrants the correct functionality
according to the attached documentation, for a period of fourteen (14) month from
invoice date (the "Warranty Period")". During the Warranty Period, Alvarion may
release to its Customers firmware updates, which include additional performance
improvements and/or bug fixes, upon availability (the "Warranty"). Bug fixes,
temporary patches and/or workarounds may be supplied as Firmware updates.
Additional hardware, if required, to install or use Firmware updates must be
purchased by the Customer. Alvarion will be obligated to support solely the two (2)
most recent Software major releases.
ALVARION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING
AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT
DOES NOT EXIST OR WAS CAUSED BY PURCHASER'S OR ANY THIRD
PERSON'S MISUSE, NEGLIGENCE, IMPROPER INSTALLATION OR IMPROPER
TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE
BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE,
LIGHTNING OR OTHER HAZARD.
Discla im e r
(a) The Software is sold on an "AS IS" basis. Alvarion, its affiliates or its licensors
MAKE NO WARRANTIES, WHATSOEVER, WHETHER EXPRESS OR IMPLIED,
WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING
DOCUMENTATION. ALVARION SPECIFICALLY DISCLAIMS ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE AND NON-INFRINGEMENT WITH RESPECT TO THE SOFTWARE.
UNITS OF PRODUCT (INCLUDING ALL THE SOFTWARE) DELIVERED TO
PURCHASER HEREUNDER ARE NOT FAULT-TOLERANT AND ARE NOT
DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE IN
APPLICATIONS WHERE THE FAILURE, MALFUNCTION OR INACCURACY OF
PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE
PHYSICAL OR ENVIRONMENTAL DAMAGE ("HIGH RISK ACTIVITIES"). HIGH
RISK ACTIVITIES MAY INCLUDE, BUT ARE NOT LIMITED TO, USE AS PART OF
ON-LINE CONTROL SYSTEMS IN HAZARDOUS ENVIRONMENTS REQUIRING
FAIL-SAFE PERFORMANCE, SUCH AS IN THE OPERATION OF NUCLEAR
FACILITIES, AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS, AIR
TRAFFIC CONTROL, LIFE SUPPORT MACHINES, WEAPONS SYSTEMS OR
OTHER APPLICATIONS REPRESENTING A SIMILAR DEGREE OF POTENTIAL
HAZARD. ALVARION SPECIFICALLY DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY OF FITNESS FOR HIGH RISK ACTIVITIES.
(b) PURCHASER'S SOLE REMEDY FOR BREACH OF THE EXPRESS
WARRANTIES ABOVE SHALL BE REPLACEMENT OR REFUND OF THE
PURCHASE PRICE AS SPECIFIED ABOVE, AT ALVARION'S OPTION. TO THE
BreezeMAX PRO 5000 CPE
Product Manual
Legal Rights
FULLEST EXTENT ALLOWED BY LAW, THE WARRANTIES AND REMEDIES SET
FORTH IN THIS AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY
OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING BUT NOT
LIMITED TO WARRANTIES, TERMS OR CONDITIONS OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY,
CORRESPONDENCE WITH DESCRIPTION, NON-INFRINGEMENT, AND
ACCURACY OF INFORMATION GENERATED. ALL OF WHICH ARE EXPRESSLY
DISCLAIMED. ALVARION' WARRANTIES HEREIN RUN ONLY TO PURCHASER,
AND ARE NOT EXTENDED TO ANY THIRD PARTIES. ALVARION NEITHER
ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY
OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION,
MAINTENANCE OR USE OF ITS PRODUCTS.
Lim it at ion of Lia bilit y
(a) ALVARION SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRD
PARTY, FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF
BUSINESS OR FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR
CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER ARISING UNDER
BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY
OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR
OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
(b) TO THE EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL
THE LIABILITY FOR DAMAGES HEREUNDER OF ALVARION OR ITS EMPLOYEES
OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT BY
PURCHASER, NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL
PARTIES REGARDING ANY PRODUCT EXCEED THE PURCHASE PRICE PAID
FOR THAT PRODUCT BY THAT PARTY (EXCEPT IN THE CASE OF A BREACH OF
A PARTY'S CONFIDENTIALITY OBLIGATIONS).
Ra dio Fre que ncy I nt e rfe re nc e St at e m e nt
The Subscriber Unit equipment has been tested and found to comply with the
limits for a class B digital device, pursuant to ETSI EN 301 489-1 rules and Part
15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a residential
environment notwithstanding use in commercial, business and industrial
environments. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications.
FCC Ra diat ion H a za rd Wa r ning
BreezeMAX PRO 5000 CPE
vi
Product Manual
Legal Rights
Indoor CPE - To comply with FCC RF exposure requirements in Section
1.1307and 2.1091 of FCC Rules, the antenna used for this transmitter must be
kept at a separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or transmitter.
Outdoor CPE - To comply with FCC RF exposure requirements in Section 1.1307
and 2.1091 of FCC Rules, the antenna be used for this transmitter must be
fixed-mounted on outdoor permanent structures with a separation distance of at
least 2m from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter.
R& T T E Com plia nc e St at e m e nt
This equipment complies with the appropriate essential requirements of Article 3
of the R&TTE Directive 1999/5/EC.
Sa fe t y Conside rat ions - Ge ne ra l
For the following safety considerations, "Instrument" means the BreezeMAX units'
components and their cables.
Ca ut ion
To avoid electrical shock, do not perform any servicing unless you are qualified to
do so.
Line Volt a ge
Before connecting this instrument to the power line, make sure that the voltage of
the power source matches the requirements of the instrument.
Ra dio
The instrument transmits radio energy during normal operation. To avoid possible
harmful exposure to this energy, do not stand or work for extended periods of time
in front of its antenna. The long-term characteristics or the possible physiological
effects of radio frequency electromagnetic fields have not been yet fully
investigated.
Out door U nit s a nd Ant e nna s I nst a llat ion a nd Grounding
Ensure that outdoor units, antennas and supporting structures are properly
installed to eliminate any physical hazard to either people or property. Make sure
that the installation of the outdoor unit, antenna and cables is performed in
accordance with all relevant national and local building and safety codes. Even
where grounding is not mandatory according to applicable regulation and national
codes, it is highly recommended to ensure that the outdoor unit and the antenna
mast (when using external antenna) are grounded and suitable lightning
protection devices are used so as to provide protection against voltage surges and
BreezeMAX PRO 5000 CPE
vii
Product Manual
Legal Rights
static charges. In any event, Alvarion is not liable for any injury, damage or
regulation violations associated with or caused by installation, grounding or
lightning protection.
Disposa l of Ele c t ronic a nd Ele c t ric a l Wa st e
Disposal of Electronic and Electrical Waste
Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with
unsorted waste. Please contact your local recycling authority for disposal of this product.
BreezeMAX PRO 5000 CPE
viii
Product Manual
Important Notice
I m por t a nt N ot ic e
This user manual is delivered subject to the following conditions and restrictions:
 This manual contains proprietary information belonging to Alvarion Ltd. Such
information is supplied solely for the purpose of assisting properly authorized
users of the respective Alvarion products.
 No part of its contents may be used for any other purpose, disclosed to any
person or firm or reproduced by any means, electronic and mechanical,
without the express prior written permission of Alvarion Ltd.
 The text and graphics are for the purpose of illustration and reference only.
The specifications on which they are based are subject to change without
notice.
 The software described in this document is furnished under a license. The
software may be used or copied only in accordance with the terms of that
license.
 Information in this document is subject to change without notice. Corporate
and individual names and data used in examples herein are fictitious unless
otherwise noted.
 Alvarion Ltd. reserves the right to alter the equipment specifications and
descriptions in this publication without prior notice. No part of this
publication shall be deemed to be part of any contract or warranty unless
specifically incorporated by reference into such contract or warranty.
 The information contained herein is merely descriptive in nature, and does not
constitute an offer for the sale of the product described herein.
 Any changes or modifications of equipment, including opening of the
equipment not expressly approved by Alvarion Ltd. will void equipment
warranty and any repair thereafter shall be charged for. It could also void the
user's authority to operate the equipment.
BreezeMAX PRO 5000 CPE
ix
Product Manual
About This Manual
About T his M a nua l
This document describes and explains how to install and manage the BreezeMAX
PRO 5000 CPE units.
This document contains the following chapters:
 Chapter 1 - Product description: Describes the PRO 5000 CPE, and its
specifications.
 Chapter 2 - Installation: Describes how to install the PRO 5000 CPE.
 Chapter 3 - Commissioning: Describes how to configure basic parameters,
align the antenna and validate unit operation.
 Chapter 4 - Operation and Administration: Describes how to use the web
interface application for configuring parameters, checking system status and
monitoring performance.
 Appendix A - Provides troubleshooting guidelines for CPE.
 Glossary - A listing of commonly used terms.
BreezeMAX PRO 5000 CPE
Product Manual
Contents
Cont e nt s
Cha pt e r 1 - Produc t De sc ript ion.............................................................. 1
1.1 Introducing BreezeMAX PRO 5000 CPEs.................................................................3
1.1.1 General ...............................................................................................................3
1.1.2 Hardware Description..........................................................................................3
1.2 Specifications .............................................................................................................5
1.2.1 Radio...................................................................................................................5
1.2.2 Sensitivity ............................................................................................................6
1.2.3 IDU/ODU Communication ...................................................................................6
1.2.4 Data Communication (Ethernet Port) ..................................................................6
1.2.5 Configuration and Management..........................................................................7
1.2.6 Environmental .....................................................................................................7
1.2.7 Standards Compliance, General .........................................................................8
1.2.8 Physical and Electrical ........................................................................................9
Cha pt e r 2 - I nst a lla t ion.......................................................................... 1 0
2.1 Installing the ODU of the CPE .................................................................................12
2.1.1 CPE Installation Requirements .........................................................................12
2.1.2 Guidelines for Positioning the ODU ..................................................................13
2.1.3 IDU-ODU Cables...............................................................................................14
2.1.4 Pole Mounting the ODU ....................................................................................15
2.1.5 Connectors........................................................................................................19
2.1.6 Connecting the Cables......................................................................................19
2.2 Installing the IDU-1D Indoor Unit of the CPE.........................................................23
2.2.1 Installation Requirements..................................................................................23
2.2.2 Location.............................................................................................................23
2.2.3 IDU Connectors and LEDs................................................................................24
2.2.4 IDU Installation..................................................................................................26
2.2.5 Grounding the ODU-IDU Cable.........................................................................28
BreezeMAX PRO 5000 CPE
xi
Product Manual
Contents
Cha pt e r 3 - Com m issioning ................................................................... 2 9
3.1 Commissioning Steps..............................................................................................31
3.2 Configuring Basic Parameters................................................................................32
3.2.1 The Basic Parameters.......................................................................................32
3.2.2 Configuration Tools ...........................................................................................33
3.2.3 Using the Web Configuration Server.................................................................33
3.3 Aligning the PRO CPE’s Internal Antenna .............................................................35
3.3.1 SU Alignment Unit (SAU) ..................................................................................35
3.3.2 Using SAU for Aligning the PRO CPE's Antenna..............................................37
3.4 Aligning the PRO CPE’s External Antenna............................................................39
3.5 Operation Verification..............................................................................................40
Cha pt e r 4 - Ope ra t ion ............................................................................ 4 1
4.1 Introduction to CPE Management...........................................................................43
4.2 Accessing the Web Configuration Server..............................................................44
4.3 Using the Web Configuration Server......................................................................45
4.4 Show All ....................................................................................................................46
4.5 Unit Control Parameters ..........................................................................................47
4.5.1 Show .................................................................................................................47
4.5.2 Reset Unit .........................................................................................................49
4.5.3 Change Password.............................................................................................50
4.5.4 SW Versions Control.........................................................................................51
4.5.5 Configuration Control ........................................................................................53
4.5.6 Licences ............................................................................................................56
4.5.7 Ethernet Operation (Op) Mode..........................................................................57
4.6 Registration Parameters..........................................................................................59
4.6.1 Show .................................................................................................................59
4.6.2 User Registration ..............................................................................................60
4.7 BST/AU Parameters .................................................................................................63
4.8 Radio Parameters.....................................................................................................67
4.8.1 Show .................................................................................................................67
4.8.2 Frequency Scanning .........................................................................................67
BreezeMAX PRO 5000 CPE
xii
Product Manual
Contents
4.8.3 Antenna Selection .............................................................................................71
4.9 ATPC Parameters .....................................................................................................72
4.9.1 Show .................................................................................................................72
4.9.2 ATPC.................................................................................................................73
4.10 Performance Monitor...............................................................................................76
4.10.1 Link Quality Counters Page ..............................................................................76
4.10.2 Ethernet Counters .............................................................................................77
4.11 Service Parameters .................................................................................................79
4.12 Management Parameters ........................................................................................82
4.12.1 Management Parameters..................................................................................82
4.12.2 DHCP Client Configuration ...............................................................................83
4.13 Logout.......................................................................................................................84
4.14 Parameters Summary ..............................................................................................85
A.1 CPE Troubleshooting...............................................................................................90
BreezeMAX PRO 5000 CPE
xiii
Product Manual
Figures
Figure s
Figure 1-1:
CPE Outdoor Units ................................................................................................ 4
Figure 1-2:
Indoor Units............................................................................................................ 4
Figure 1-3:
SU Alignment Unit (SAU) ....................................................................................... 4
Figure 2-1:
ODU Pole Installation Using the Special Clamp, Arrow Facing Upwards ............ 16
Figure 2-2:
ODU Pole Installation Using the Special Clamp, Arrow Facing Rightwards ........ 17
Figure 2-3:
ODU Pole Installation Using the Tilt Accessory, Vertical Polarization ................. 18
Figure 2-4:
Bottom Panel of the ODU (SA/SE model without sealing covers) ....................... 19
Figure 2-5:
Top Panel of the ODU (SE model)....................................................................... 19
Figure 2-6:
Ethernet Connector Pin Assignments .................................................................. 21
Figure 2-7:
Inserting the IDU COM Cable into the Sealing Cap ............................................. 22
Figure 2-8:
CPE-IDU-1D Front Panel ..................................................................................... 24
Figure 2-9:
CPE-IDU-1D 3D View .......................................................................................... 24
Figure 2-10:
XTRM-SU-IDU-1D................................................................................................ 26
Figure 2-11:
Exposing the Drain Wire ...................................................................................... 28
Figure 3-1:
Login Window ...................................................................................................... 34
Figure 3-2:
SAU...................................................................................................................... 35
Figure 4-1:
Web Configuration Server - Main Window ........................................................... 44
Figure 4-2:
Reset Unit Page ................................................................................................... 49
Figure 4-3:
Change Password Page ...................................................................................... 50
Figure 4-4:
SW Versions Control Page .................................................................................. 51
Figure 4-5:
Configuration Control Page.................................................................................. 53
Figure 4-6:
License Control Page........................................................................................... 56
Figure 4-7:
Ethernet Operation Mode Page ........................................................................... 57
Figure 4-8:
Registration Show Page ...................................................................................... 59
Figure 4-9:
User Registration Page ........................................................................................ 60
Figure 4-10:
BST/AU Page....................................................................................................... 64
Figure 4-11:
Radio - Show Page .............................................................................................. 67
BreezeMAX PRO 5000 CPE
xiv
Product Manual
Figures
Figure 4-12:
Frequency Scanning Page................................................................................... 69
Figure 4-13:
Antenna Selection Page ...................................................................................... 71
Figure 4-14:
ATPC Show Page ................................................................................................ 72
Figure 4-15:
Multi rate and ATPC Parameters Page................................................................ 73
Figure 4-16:
Link Quality On-line Display Page........................................................................ 76
Figure 4-17:
Ethernet Counters Page ...................................................................................... 77
Figure 4-18:
Service Page - IP CS Mode (Show Parameters) ................................................. 79
Figure 4-19:
Change Service Parameters - Ethernet CS Mode ............................................... 79
Figure 4-20:
Management Page............................................................................................... 82
Figure 4-21:
Dhcp Client Configuration .................................................................................... 83
Figure 4-22:
Logout Page......................................................................................................... 84
BreezeMAX PRO 5000 CPE
xv
Product Manual
Tables
Ta ble s
Table 1-1: Radio Specifications..................................................................................................... 5
Table 1-2: Sensitivity ..................................................................................................................... 6
Table 1-3: ODU/ODU Communication .......................................................................................... 6
Table 1-4: Data Communication (Ethernet Port) ........................................................................... 6
Table 1-5: Configuration and Management................................................................................... 7
Table 1-6: Environmental Specifications ....................................................................................... 7
Table 1-7: Environmental Specifications ....................................................................................... 7
Table 1-8: Standard Compliance Specifications ........................................................................... 8
Table 1-9: Mechanical Specifications............................................................................................ 9
Table 1-10: Electrical Specifications ............................................................................................. 9
Table 1-11: Connectors................................................................................................................. 9
Table 2-1: Approved Category 5E Ethernet Cables .................................................................... 14
Table 2-2: CPE-ODU-PRO Connectors ...................................................................................... 19
Table 2-3: Cable Color Codes..................................................................................................... 21
Table 2-4: CPE-IDU-1D Connectors ........................................................................................... 24
Table 2-5: CPE-IDU-1D LEDs..................................................................................................... 25
Table 2-6: XTRM-SU-IDU-1D Connectors .................................................................................. 26
Table 2-7: XTRM-SU-IDU-1D LED.............................................................................................. 26
Table 3-1: CPE Basic Parameters .............................................................................................. 32
Table 3-2: SAU LEDs .................................................................................................................. 36
Table 3-3: SAU LINK QUALITY LEDs Functionality ................................................................... 36
Table 4-1: Intermediate Steps ..................................................................................................... 68
Table 4-2: Country Codes ........................................................................................................... 74
BreezeMAX PRO 5000 CPE
xvi
Product Manual
Tables
Table 4-3: CPE Parameters Summary........................................................................................ 85
BreezeMAX PRO 5000 CPE
xvii
Product Manual
Chapter
Product Description
Chapter 1 - Product Description
I n T his Cha pt e r:
 “Introducing BreezeMAX PRO 5000 CPEs” on page 3
 “Specifications” on page 5
BreezeMAX PRO 5000 CPE
Product Manual
Chapter 1 - Product Description
Introducing BreezeMAX PRO 5000 CPEs
1 .1
I nt roduc ing Bre e ze M AX PRO 5 0 0 0 CPEs
1 .1 .1
Ge ne ra l
The WiMAX-compatible BreezeMAX PRO 5000 CPE Subscriber Units (SUs) are
powered by Sequans chipset.
BreezeMAX PRO 5000 CPE is currently available in the 5 GHz frequency band,
1 Data.
Differentiation between models of this product is based on its description:
XTRM-SU-OD-1D-4.9-- - indicates capacity limitation – 2, 6, UL
  - indicates antenna configuration – A for attached integrated antenna, E
for external antenna
For example: XTRM-SU-OD-1D-4.9-6-E
The units support the TR-069 CPE WAN Management Protocol (CWMP), allowing
efficient management by an Auto Configuration Server (ACS).
In addition, configuration and performance monitoring of a single unit can be
performed using the following options:
 Using a PC/Notebook with an HTTP browser to access the built-in web
configuration server.
 Using TFTP to upload/download a Configuration File.
1 .1 .2
H a rdw a re De sc ript ion
The PRO CPE comprises an Outdoor Unit (ODU) and an Indoor Unit (IDU).
The ODU includes the modem, radio, data processing and management
components of the SU. It also includes an integral high-gain flat antenna or a
connection to two external antennas. The ODU connects to the IDU and to the
user's equipment through a 10/100BaseT Ethernet port.
BreezeMAX PRO 5000 CPE
Product Manual
Chapter 1 - Product Description
Introducing BreezeMAX PRO 5000 CPEs
Figure 1-1: CPE Outdoor Units
The indoor unit is powered from the mains and connects to the ODU via a
Category 5E Ethernet cable carrying the Ethernet data between the two units, as
well as power (-54 VDC) and control signals to the ODU and status indications
from the ODU.
Figure 1-2: Indoor Units
A miniature SU Alignment Unit (SAU), that includes signal strength and status
indicators, is also available to support easy and convenient antenna alignment
and status verification.
Figure 1-3: SU Alignment Unit (SAU)
BreezeMAX PRO 5000 CPE
Product Manual
Chapter 1 - Product Description
Specifications
1 .2
Spe c ific at ions
1 .2 .1
Ra dio
Table 1-1: Radio Specifications
Item
Details
Frequency
Band
Frequencies (MHz)
5 GHz
4900-5950
Operation Mode
 TDD, Half Duplex
Channel Bandwidth
 5 MHz
 10 MHz
Central Frequency
Resolution
0.125 MHz
5 GHz Integral Antenna
Embedded dual polarization antenna, 16dBi, 15°AZ x 15°EL
Antenna Port (units with
external antenna)
N-Type, 50 Ohm
5 GHz Detached
Antennasa
 UNI-23-9: 23 dBi, 5.150-5.875 GHz,
9° horizontal x 9° vertical, vertical polarization, compliant with ETSI EN 302 326-3
V1.2.1 (2007-01)
 UNI-28-4: 28 dBi, 5.150-5.875 GHz,
4.5° horizontal x 4.5° vertical, vertical polarization, compliant with ETSI EN 302
326-3 V1.2.1 (2007-01)
 Omni antenna (AN1435, 4.9-5.875 GHz, BS, Omni, 9.5dBi)
Max. Input Power 
(at antenna port)
-20 dBm before saturation
0 dBm before damage
Output Power
(at antenna port)
Up to 21dBm ±1dB Maximum
Modulation
OFDM modulation, 1024/512 FFT points: QPSK, QAM16, QAM64
Access Method
OFDMA
FEC
Convolutional Coding: 1/2, 2/3, 3/4, 5/6
a. In 5.4 GHz units with a detached antenna, if the gain of the antenna (as inserted into Antenna gain field)
is higher than 30 dBm, then the Maximum EIRP can vary by more than ±3 dB. As regulations in most
countries limit the EIRP of units operating in the 5.4 GHz band, it is recommended to use detached antennas up to and including 28 dBi.
BreezeMAX PRO 5000 CPE
Product Manual
Chapter 1 - Product Description
1 .2 .2
Specifications
Se nsit ivit y
Table 1-2: Sensitivity
1 .2 .3
Modulation & Coding
Sensitivity (dBm)
@ 5 MHz BW
Sensitivity (dBm)
@ 10 MHz BW
QPSK 1/2
-96
-93
QPSK 3/4
-93
-90
16QAM 1/2
-89
-86
16QAM 3/4
-86
-83
64QAM 2/3
-81
-78
64QAM 3/4
-80
-77
64QAM 5/6
-79
-76
I DU /ODU Com m unic at ion
Table 1-3: ODU/ODU Communication
Item
Details
Cable Type
Category 5E, Outdoor Data Cable, Double Jacket, 4x2x24# FTP
Maximum Length
90 meter
1 .2 .4
Dat a Com m unic at ion (Et he r ne t Por t )
Table 1-4: Data Communication (Ethernet Port)
Item
Details
Standard Compliance
IEEE 802.3 CSMA/CD
Maximum Frame Size (including 4 CRC bytes)
1522 Bytes
Speed
10/100 Mbps, Half/Full Duplex with Auto Negotiation
BreezeMAX PRO 5000 CPE
Product Manual
Chapter 1 - Product Description
1 .2 .5
Specifications
Configurat ion a nd M a na ge m e nt
Table 1-5: Configuration and Management
Item
Description
Management options
 Web-based (HTTP/HTTPS)
 TR-069
 TFTP
Management access
From Wired LAN, Wireless Link
Management access protection
Access Password
Allocation of IP parameters
WAN - DHCP, options 43, 60, 66, 67
Software upgrade
HTTP/TFTP
Configuration Upload/Download
HTTP/TFTP
Authentication
TTLS
1 .2 .6
Environm e nt a l
1.2.6.1
IDU
Table 1-6: Environmental Specifications
Item
Details
Operating Temperature
 CPE IDU-1D: -5ºC to 45ºC
 XTRM-SU-IDU-1D: 0°C to 40°C
Storage Temperature
 CPE IDU-1D: -40 to 75 °C
 XTRM-SU-IDU-1D: -30°C to 85°C
Humidity
1.2.6.2
Maximum 95%, non-condensing.
ODU
Table 1-7: Environmental Specifications
Item
Details
Operating Temperature
-40ºC to 55ºC
Storage Temperature
-40 to 70 °C
Humidity
Maximum 95%, non-condensing.
Rain
IEC 67
BreezeMAX PRO 5000 CPE
Product Manual
Chapter 1 - Product Description
Specifications
Table 1-7: Environmental Specifications (Continued)
Item
Details
Random Vibration
IEC 68-2-64
Shock
IEC-68-2-29
Salt Fog
IEC-68-2-11
Ice Loading
25mm radial ice density 7kN/m3
Solar Radiation
IEC-68-2-5, MIL-STD-810D
Wind Speed
160Km/Hr required for antenna stability under operation
1 .2 .7
St a nda rds Com plia nc e , Ge ne ra l
Table 1-8: Standard Compliance Specifications
Type
Standard
EMC
 FCC Part 15B Class B
 EN 55022 Class B
 EN 301 489-1/4
Safety
 UL 60950-1/-22
 IEC/EN 60950-1/-22
Telecom
 ITU-T K21
Standards
 EN 302 326
 EN 302 085, V1.2.2 (2003-08) Range 1
 EN 301 893 v1.5.1
 FCC Part 15 C and E
 IEEE 802.3-2005 10BASE-T and 100BASE-TX
 FCC-06-96A1
WiMAX Radio Signal
Certification
BreezeMAX PRO 5000 CPE
 IEEE 802.16e-2005 WAVE 1 and WAVE 2
Product Manual
Chapter 1 - Product Description
Specifications
1 .2 .8
Physic a l a nd Ele c t ric a l
1.2.8.1
Mechanical
Table 1-9: Mechanical Specifications
Unit
Dimensions (mm)
Weight (kg)
CPE-IDU
156mm (L) X 60mm (W) X 33mm (T) or
0.3
95mm(L) X 57mm (W) X 32mm (T)
0.2
CPE-ODU-PRO-SA
230mm (H) X 230mm (W) X 63mm (T)
CPE-ODU-PRO-SE
230mm (H) X 260mm (W) X 73mm (T)
1.2.8.2
Electrical
Table 1-10: Electrical Specifications
Item
Details
Power Consumption
16.5W
CPE-IDU Power Input
100-240 VAC, 47-63 Hz
CPE-ODU-PRO Power Input
54 VDC (or 48VDC) from the IDU over the indoor-outdoor Ethernet
cable
1.2.8.3
Connectors
Table 1-11: Connectors
Unit
Connector
Details
CPE-IDU-1D
ETHERNET/LAN
10/100Base-T (RJ-45).Cable connection to a PC: Straight
cable
Connection to a hub: Crossed
CPE-ODU-PRO-SA
CPE-ODU-PRO-SE
BreezeMAX PRO 5000 CPE
RADIO/LAN+DC
10/100Base-T (RJ-45)
AC IN
3 pin AC power plug
IDU COM
10/100Base-T (RJ-45)
SAU
Special mini USB
IDU COM
10/100Base-T (RJ-45)
SAU
Special mini USB
2x ANT (SE model)
N-Type jack, 50 Ohm, lightning protected
Product Manual
Chapter
Installation
Chapter 2 - Installation
I n T his Cha pt e r:
 “Installing the ODU of the CPE” on page 12
 “Installing the IDU-1D Indoor Unit of the CPE” on page 23
BreezeMAX PRO 5000 CPE
11
Product Manual
Chapter 2 - Installation
2 .1
Installing the ODU of the CPE
I nst a lling t he ODU of t he CPE
The following sections describe how to install the outdoor unit (ODU) of the PRO
CPE. CPE operation is exclusive for point to point and requires professional
installation.
CAUTION
ONLY experienced installation professionals who are familiar with local building and safety codes
and, wherever applicable, are licensed by the appropriate government regulatory authorities should
install outdoor units and antennas.
Failure to do so may void the product warranty and may expose the end user or Service Provider to
legal and financial liabilities. Alvarion and its resellers or distributors are not liable for injury, damage
or regulation violations associated with the installation of Outdoor Units or antennas.
2 .1 .1
CPE I nst a llat ion Re quire m e nt s
2.1.1.1
Packing List
The PRO CPE includes the following components:
 ODU Package:
»
CPE ODU unit of chosen model
»
Mounting kit
»
Quick Installation Guide
»
Optional software utilities and User Guide CD
 IDU Package:
»
CPE IDU unit, comprising of AC power adapter and internal gateway
 Power Cable Package:
»
AC/DC power cable
BreezeMAX PRO 5000 CPE
12
Product Manual
Chapter 2 - Installation
2.1.1.2
Installing the ODU of the CPE
Additional Installation Requirements
The following items are also required to install the ODU:
 Double shielded Cat.5E outdoor ethernet cable with two RJ-45 connectors*
(90m) (see Section 2.1.3 for details on approved cables and maximum length),
and an RJ-45 connectors crimping tool.
 For units that connect to external antenna: Antenna(s)* and RF cable* for
connecting the antenna to the ODU.
 SAU* (SU Alignment Unit) for antenna alignment and status verification.
 Grounding cable with an appropriate termination.
 Installation tools and materials, including appropriate means (e.g. a 1" to 4"
pole) for installing the ODU (and antenna where applicable).
2.1.1.3
Optional Items
 Tilt Pole Mounting kit*.
NOTE
Items marked with an asterisk (*) are available from Alvarion.
2 .1 .2
Guide line s for Posit ioning t he ODU
This section provides key guidelines for selecting the optimal installation locations
for the ODU.
Select the optimal locations for the equipment using the following guidelines:
 The ODU should be mounted on a 1"-4" pole. Its location should enable easy
access to the unit and its connectors for installation and testing.
 The higher the placement of the ODU/antenna, the better the achievable link
quality.
 The ODU/antenna should be installed to provide a direct, or near line of sight
with the BTS antenna(s). The ODU/antenna should be aligned to face the
general direction of the BTS.
BreezeMAX PRO 5000 CPE
13
Product Manual
Chapter 2 - Installation
Installing the ODU of the CPE
 In some cases it might be necessary to up/down-tilt the antenna. An optional
Tilt accessory for the ODU providing a tilt range of ±15° is available. The tilt
option may be necessary to either improve the link conditions or, if the SU is
too close to the BTS, to reduce the receive signals strength. As a rule of thumb,
if the SU is located at a distance of less than 300 meters from the BTS, it is
recommended to up-tilt the antenna by approximately 10° to 15° (especially in
line-of-sight conditions) to avoid saturation of the receivers by too strong
signals.
 Outdoor units with a connection to an external antenna should be installed as
close as possible to the antenna.
 The equipment is designed for fixed, point-to-point operation. That is, in the
same time, the same CPE cannot connect to multiple BTSs; It is the
responsibility of the operator and the installer to take into account that - at
least in the 5725-5850 MHz band - the equipment excludes the use of point-to
multipoint systems, omnidirectional applications, and multiple co-located
intentional radiators transmitting the same information.
2 .1 .3
I DU -ODU Ca ble s
NOTE
The length of the Indoor-to-Outdoor cable should not exceed 90 meters. The length of the
Indoor-to-Outdoor cable, together with the length of the Ethernet cable connecting the CPE-IDU-1D
to the data equipment, should not exceed 100 meters.
Use only Category 5E Ethernet cables from either Alvarion or any of the approved
manufacturers, listed in Table 2-1. Consult with Alvarion's specialists on the
suitability of other cables.
Table 2-1: Approved Category 5E Ethernet Cables
Manufacturer
Part Number
Superior Cables Ltd. 
www.superior-cables.com
612098
HES Cabling Systems
H5E-00481
www.hescs.com
Teldor
www.teldor.com
BreezeMAX PRO 5000 CPE
8393204101
14
Product Manual
Chapter 2 - Installation
Installing the ODU of the CPE
Table 2-1: Approved Category 5E Ethernet Cables
Manufacturer
Part Number
Southbay Holdings Limited
11th Fl., 15, Lane 347, Jong Jeng Rd.
Shin Juang City, Taipei County
Taiwan, R.O.C.
Attn: Eva Lin
Tel. 886-2-2832 3339
Fax. 886-2-2206 0081
E-mail: eva@south-bay.com.tw
TSM2404A0D
GU-Tech., LLC . - A Member of OVIS GroupTel/Fax :
732 918 8221 Mobile: 718 909 4093
www.OVIS.COM.TW www.GU-TECH.COM
In case of missing information in the manufacturer's WEB site (product
specifications, ordering issues, etc.), it is highly recommended to contact the
manufacturer's sales representative directly.
2 .1 .4
Pole M ount ing t he ODU
The ODU can be mounted on a 1" to 4" pole using one of the following options:
 A pole mounting kit is supplied with each unit. The kit includes a special
clamp and a pair of threaded rods, flat washers, spring washers and nuts.
There are two pairs of threaded holes on the back of the unit, enabling to use
the mounting kit for installing the unit using either vertical or horizontal
polarization. The clamp enables installing the unit on diverse pole diameters
from 1" to 4".
 A Tilt Pole Mounting kit, providing a tilt range of ±15° is available. The Tilt kit
can be attached to the ODU and be mounted on a 1" to 4" pole using two 9/16"
wide metal bands.
2.1.4.1
Pole Mounting the ODU Using the Clamp
Figure 2-1 and Figure 2-2 illustrate how to mount an ODU on a pole, using the
clamp and threaded rods.
BreezeMAX PRO 5000 CPE
15
Product Manual
Chapter 2 - Installation
Installing the ODU of the CPE
NOTE
 There is a groove on one end of the threaded rod. Insert the rods with the grooves pointing
outward, and fasten them to the unit using a screwdriver. Install the unit with the bottom panel,
which includes the connectors, facing downward.
 You can install the ODU with the arrow on the back of the unit facing upwards or rightwards.
Match the polarity of the transmission antenna to the polarity of the receiver antenna.
 Make sure that the connectors are facing downwards.
Grounding
screw
Figure 2-1: ODU Pole Installation Using the Special Clamp, Arrow Facing Upwards
BreezeMAX PRO 5000 CPE
16
Product Manual
Chapter 2 - Installation
Installing the ODU of the CPE
Figure 2-2: ODU Pole Installation Using the Special Clamp, Arrow Facing Rightwards
BreezeMAX PRO 5000 CPE
17
Product Manual
Chapter 2 - Installation
2.1.4.2
Installing the ODU of the CPE
Pole Mounting the ODU with the Tilt Accessory
Figure 2-3: ODU Pole Installation Using the Tilt Accessory, Vertical Polarization
To mount the ODU on a pole using the Tilt accessory:
Attach the Tilt accessory to the ODU using the two pairs of flat washers, spring
washers and nuts supplied in the Tilt kit.
Mount the Tilt accessory on a 1" to 4" pole using two 9/16" metal bands.
Release slightly the Tilt Control Screw, tilt the ODU downward/upward as
required, and re-tighten the screw.
BreezeMAX PRO 5000 CPE
18
Product Manual
Chapter 2 - Installation
2 .1 .5
Installing the ODU of the CPE
Conne c t ors
SAU Port
IDU COM
Figure 2-4: Bottom Panel of the ODU (SA/SE model without sealing covers)
Figure 2-5: Top Panel of the ODU (SE model)
Table 2-2: CPE-ODU-PRO Connectors
Name
Connector
Functionality
IDU COM
10/100Base-T (RJ-45)
Connection to the IDU
SAU
Special mini USB
Connection to SAU
N-Type jack, 50 Ohm
Connection to an external antenna
(ANT, only in SE model) x2
2 .1 .6
Conne c t ing t he Ca ble s
2.1.6.1
Connecting the Grounding Cable
The Grounding screw (marked
) is located on the back panel of the ODU (see
Figure 2-1).
To connect the grounding cable:
Connect one end of a grounding cable to the grounding screw and tighten the
grounding screw firmly.
BreezeMAX PRO 5000 CPE
19
Product Manual
Chapter 2 - Installation
Installing the ODU of the CPE
Connect the other end of the grounding cable to a good ground (earth)
connection.
2.1.6.2
Connecting the IDU-ODU Cable
CAUTION
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer. See list of
approved cables in Table 2-1.The length of the Indoor-to-Outdoor cable should not exceed 90
meters. The length of the Indoor-to-Outdoor cable, together with the length of the Ethernet cable
connecting the CPE-IDU-1D to the data equipment, should not exceed 100 meters.
To prepare the IDU-ODU cable:
Use a crimp tool for RJ-45 connectors to prepare the wires. Insert them into the
appropriate pins and use the tool to crimp the connector. Make sure to do the
following:
 Remove as small a length as possible of the external jacket. Verify that the
external jacket is well inside the sealing cover when connected to the unit, to
ensure good sealing.
 Pull back the shield drain wire before inserting the cable into the RJ-45
connector, to ensure a good connection with the connector's shield after
crimping.
The IDU-ODU cable provides pin-to-pin connection on both ends.
The following figure shows the required wire pair connections.
BreezeMAX PRO 5000 CPE
20
Product Manual
Chapter 2 - Installation
Installing the ODU of the CPE
Figure 2-6: Ethernet Connector Pin Assignments
Data pairs are 1&2, 3&6.
Power pair (proprietary solution) is 4&5.
The color codes used in standard cables supplied by Alvarion are as listed in the
following table:
Table 2-3: Cable Color Codes
Wire color
Pin
Blue
Blue/white
Orange
Orange/white
Brown
Brown/white
Green
Green/white
To connect the IDU-ODU cable:
The seal has a special groove allowing to insert an ethernet cable with an
already assembled RJ-45 connector. Strip the cable sheath and crimp the
RJ-45 plug.
BreezeMAX PRO 5000 CPE
21
Product Manual
Chapter 2 - Installation
Installing the ODU of the CPE
Insert the cable with the assembled connector through the sealing nut.
To expose the groove, lightly squeeze the seal. Carefully insert the cable
through the groove.
Insert the cable through the housing and insert the seal at the back end of the
housing.
Tighten the sealing nut onto the housing.
Stricken the gasket on the front end of the housing.
Sealing nut
Seal
Housing
Gasket
Figure 2-7: Inserting the IDU COM Cable into the Sealing Cap
Connect the Ethernet cable to the IDU COM RJ-45 connector and tighten the
sealing cap.
Route the cable to the location selected for the indoor equipment.
Assemble an RJ-45 connector with a protective cover on the indoor end of the
IDU-ODU cable. Refer to the pin assignment and color codes in standard
cables described above.
2.1.6.3
Connecting the Antenna Cable (units with external antenna)
To connect the RF cable:
Mount the antenna as close as possible to the ODU.
Connect one end of the coaxial RF cable to the RF connector (marked
located at the top panel of the unit (see Figure 2-5).
Connect the other end of the RF cable to the antenna.
The RF connectors should be properly sealed to protect against rain and
moisture.
BreezeMAX PRO 5000 CPE
22
Product Manual
Chapter 2 - Installation
Installing the IDU-1D Indoor Unit of the CPE
2 .2
I nst a lling t he I DU -1 D I ndoor U nit of t he
CPE
2 .2 .1
I nst a llat ion Re quire m e nt s
2.2.1.1
Packing List
 BMAX-CPE-IDU-1D or XTRM-SU-IDU-1D
 Wall mounting kit
2.2.1.2
Additional Installation Requirements
 Ethernet cable(s): a crossed cable if connecting to a hub/switch and a straight
cable if connecting directly to a PC Network Interface Card (NIC).
NOTE
The length of the Ethernet cable connecting CPE-IDU-1D to the user's equipment, together with the
length of the IDU-ODU cable, should not exceed 100 meters.
 Mains power cord
 Mains plug adapter or termination plug (if the power plug on the supplied AC
power cord does not fit local power outlets).
 For configuring parameters: a Portable PC/Notebook and a straight Ethernet
cable for configuring parameters using a web browser.
 Other installation tools and materials (a drill for wall-mounting the unit,
means for securing cables to walls, etc.)
2 .2 .2
Loc at ion
The unit can be placed on a desktop or a shelf. Alternatively, it can be
wall-mounted using the mounting kit and guidelines supplied with the unit.
BreezeMAX PRO 5000 CPE
23
Product Manual
Chapter 2 - Installation
Installing the IDU-1D Indoor Unit of the CPE
2 .2 .3
I DU Conne c t ors a nd LEDs
2.2.3.1
CPE IDU-1D Connectors and LEDs
Figure 2-8: CPE-IDU-1D Front Panel
Figure 2-9: CPE-IDU-1D 3D View
Table 2-4: CPE-IDU-1D Connectors
Name
Connector
Functionality
ETHERNET (4)
(on the side panel)
10/100Base-T (RJ-45) with 2
embedded LEDs
Connection to the user's LAN/PC
Cable connection to a hub/switch/router: Crossed
Cable connection to a PC: Straight
BreezeMAX PRO 5000 CPE
24
Product Manual
Chapter 2 - Installation
Installing the IDU-1D Indoor Unit of the CPE
Table 2-4: CPE-IDU-1D Connectors
Name
Connector
Functionality
RADIO
(on the front panel)
10/100Base-T (RJ-45)
Connection to the ODU
POWER
(on the bottom panel)
3-pin AC
Mains power connection
Table 2-5: CPE-IDU-1D LEDs
Name
Description
Functionality
POWER (3)
Power Indication
 Off - IDU is not powered or power failed
 Green - IDU power is OK
ETH (2)
Ethernet link status
(Ethernet integrity)
 Off - No Ethernet connectivity has been detected between
the outdoor unit and the device connected to the indoor
unit’s data port
 Green - Ethernet connectivity has been detected between
the outdoor unit and the device connected to the indoor
unit’s data port
WIRELESS (1)
Wireless link status
 Off - SU is not associated with a BS
 Green - SU is connected with a BS (network entry
completed)
 Blinking Green - Authentication failed
* After power-up, the WIRELESS LED illuminates until self-test is finished.
The CPE IDU-1D includes a recessed RESET button located on the front panel of
the unit. When pressed, power to the ODU is disconnected (hard reset).
BreezeMAX PRO 5000 CPE
25
Product Manual
Chapter 2 - Installation
2.2.3.2
Installing the IDU-1D Indoor Unit of the CPE
XTRM-SU-IDU-1D Connectors and LEDs
Figure 2-10: XTRM-SU-IDU-1D
Table 2-6: XTRM-SU-IDU-1D Connectors
Name
Connector
Functionality
LAN
10/100Base-T (RJ-45) with 2
embedded LEDs
Connection to the user's LAN/PC
Cable connection to a hub/switch/router: Crossed
Cable connection to a PC: Straight
LAN+DC
10/100Base-T (RJ-45)
Connection to the ODU
POWER
3-pin AC
Mains power connection
Table 2-7: XTRM-SU-IDU-1D LED
Name
Description
Functionality
POWER
Power Indication
 Off - IDU is not powered or power failed
 Green - IDU power is OK
2 .2 .4
I DU I nst a llat ion
To install the IDU:
It is assumed that the IDU-ODU cable is already connected to the ODU.
Assemble an RJ-45 connector with a protective cover on the indoor end of the
IDU-ODU cable. Refer to Section 2.1.6.2 for instructions on preparing the
cable.
BreezeMAX PRO 5000 CPE
26
Product Manual
Chapter 2 - Installation
Installing the IDU-1D Indoor Unit of the CPE
Connect the IDU-ODU cable to the RADIO/LAN+DC connector (See Figure 2-8
and Figure 2-10).
CAUTION
Do not connect the data equipment to the RADIO/LAN+DC port. The RADIO/LAN+DC port supplies
DC power to the ODU, and this may harm other equipment connected to it.
Connect the power cord to the unit's AC socket, located on the rear panel.
Connect the other end of the power cord to the AC mains after verifying that
the unit is rated for the voltage in the country of use; the AC range is indicated
on the back side of the CPE-IDU-1D.
NOTE
The color codes of the power cable are as follows:
Brown
Phase
Blue
Neutral
Yellow/Green
Ground
To comply with safety regulations, the shield of the ODU-IDU outdoor-rated
Ethernet cable must be connected to protective ground (earth). The grounding
point can be either inside the building, or immediately at the entry point to the
building, depending on where a protective ground is available. See “Grounding
the ODU-IDU Cable” on page 28.
CAUTION
Grounding the ODU-IDU Ethernet cable must be performed by a professional installer in
conformance with local safety regulations.
Verify that the POWER LED located on the front panel is lit, indicating that the
unit is supplying power to the radio port.
Configure the basic parameters and align the antenna as described in the
applicable sections of Chapter 3.
Connect the 10/100 Base-T ETHERNET connector(s) to the data equipment.
The cable connection should be a crossed Ethernet if connecting to a
hub/switch and a straight cable if connecting directly to a PC Network
Interface Card (NIC).
NOTE
The length of the Ethernet cable connecting CPE-IDU-1D to the user's equipment, together with the
length of the IDU-ODU cable, should not exceed 100 meters.
BreezeMAX PRO 5000 CPE
27
Product Manual
Chapter 2 - Installation
2 .2 .5
Installing the IDU-1D Indoor Unit of the CPE
Verify proper operation as described in the applicable section of Chapter 3.
Grounding t he ODU -I DU Ca ble
Follow the instructions below to ground the ODU-IDU cable. The following
paragraphs describe one method for grounding the outdoor-rated Category 5E
Ethernet cable through its drain wire. The actual connection method employed
is left to the professional installer.
To ground the ODU-IDU Ethernet cable, follow these steps:
Strip back about a one inch (2.4 cm) section of the Ethernet cable jacket to
expose the drain wire.
Drain Wire
Figure 2-11: Exposing the Drain Wire
Attach a grounding cable to the drain wire and then connect it to protective
earth.
Use weatherproof tape to cover and seal the attachment area on the Ethernet
cable.
BreezeMAX PRO 5000 CPE
28
Product Manual
Chapter
Commissioning
Chapter 3 - Commissioning
I n T his Cha pt e r:
 “Commissioning Steps” on page 31
 “Configuring Basic Parameters” on page 32
 “Aligning the PRO CPE’s Internal Antenna” on page 35
 “Operation Verification” on page 40
BreezeMAX PRO 5000 CPE
30
Product Manual
Chapter 3 - Commissioning
3 .1
Commissioning Steps
Com m issioning St e ps
After completing the installation process, as described in the preceding chapter,
several actions should be performed to ensure connectivity with a BTS and
provisioning of services. After the CPE is connected with a BTS, it can be fully
managed via the wireless link:
The basic parameters must be configured to ensure that the unit operates
correctly and can communicate with a BTS.
The antenna must be aligned to ensure optimal performance of the wireless
link.
Proper operation should be verified, including data connectivity.
BreezeMAX PRO 5000 CPE
31
Product Manual
Chapter 3 - Commissioning
Configuring Basic Parameters
3 .2
Configuring Ba sic Pa ra m e t e rs
3 .2 .1
T he Ba sic Pa ra m e t e rs
Table 3-1: CPE Basic Parameters
Parameter
Default Value
Comment
Country Code
Ethernet Port auto Negotiation
Enable/Disable
Must be set in accordance to
designated country and deployment
scenario
Enabled
Ethernet Port Speed and Duplex
Applicable only if Ethernet Auto
Negotiation Enable/Disable is set to
Disable
User Name
CPEMACaddress@WiMax.com
Should be supplied by system
administrator/operator
User Password
Empty
Should be supplied by system
administrator/operator
Organization
Empty
Address
Empty
Country
Empty
BST/AU ID
0.0.0.0.0.0
BST/AU ID Mask
0.0.0.0.0.0
Preferred BST/AU ID
0.0.0.0.0.0
Preferred BST/AU ID Mask
0.0.0.0.0.0
Bandwidth
Auto (5/10 MHz)
Start Rx Frequency (KHz)
Depends on Radio Band and
Bandwidth
End Rx Frequency (KHz)
Depends on Radio Band and
Bandwidth
Scanning Main Step
2.5 MHz
Discrete Scanning Frequencies
Null (empty list)
BreezeMAX PRO 5000 CPE
32
Product Manual
Chapter 3 - Commissioning
Configuring Basic Parameters
NOTE
Most parameters are changed to their new values only after reset (refer to Section 4.14 for more
details). Once the basic parameters are configured, the unit should be reset in order to activate the
new configuration.
3 .2 .2
Configurat ion Tools
The CPEs include a Web Configuration Server, providing a web-based GUI for
local configuration and monitoring. The Web Configuration Server can be
accessed using a PC/Notebook with a web browser.
The CPE may be delivered with the operator’s default settings already configured
in the FLASH memory. The only parameters that should be configured (if
necessary) are the end user’s credentials (User Name and User Password).
3 .2 .3
U sing t he We b Configurat ion Se r ve r
To configure basic parameters:
Connect a PC/Notebook with a web browser to the Ethernet port of the CPE,
using a straight Ethernet cable.
Configure the PC's IP parameters to enable connectivity with the unit. The IP
address of the CPE for local management access is 192.168.254.251. The
Subnet Mask is 255.255.255.0. The recommended IP address for the PC is
192.168.254.250, as this is also the default TFTP Sever IP Address (required
for downloading SW versions and for downloading/uploading configuration
files).
Open a web browser, and connect to http://192.168.254.251. The “Enter the
Password” prompt is displayed. Enter the password and press the Enter key.
NOTE
The default password is "installer".
BreezeMAX PRO 5000 CPE
33
Product Manual
Chapter 3 - Commissioning
Configuring Basic Parameters
Figure 3-1: Login Window
The Main window of the Web Configuration Server is displayed, enabling
access to the required parameters configuration and performance monitoring
options. Refer to Chapter 4 for instructions on using the Web Configuration
Server and detailed information on the various parameters and other features
supported.
Configure the basic parameters listed in Table 3-1.
Reset the unit to apply the new settings and enable synchronization with a BS.
BreezeMAX PRO 5000 CPE
34
Product Manual
Chapter 3 - Commissioning
Aligning the PRO CPE’s Internal Antenna
3 .3
Aligning t he PRO CPE’s I nt e r na l Ant e nna
3 .3 .1
SU Alignm e nt U nit (SAU )
The miniature SU Alignment Unit can be used during installation and testing to
support an easy process of antenna alignment and provide the ODU's status
indications.
To connect the SAU to the ODU:
Remove the sealing cap of the ODU's SAU connector.
Connect the cable attached to the SAU to the SAU connector.
After completing the installation, disconnect the cable and replace the cap.
Use appropriate sealing material to protect the connection against moisture and
humidity. Use removable sealing material, such as a tar seal, to enable future
access to the connector.
Figure 3-2: SAU
BreezeMAX PRO 5000 CPE
35
Product Manual
Chapter 3 - Commissioning
Aligning the PRO CPE’s Internal Antenna
Table 3-2: SAU LEDs
Name
Description
Functionality
AL
Alarm indication
 Off - ODU is OK, diagnostic test passed
 Red - ODU failure
PW
 Off - ODU is not powered or 3.3 VDC failure
Power indication
 Green - ODU power to SAU is OK
ET
 Off - No Ethernet connectivity has been
Ethernet link status
indication
(Ethernet integrity)
detected between the outdoor unit and the
device connected to the indoor unit’s
Ethernet port
 Green- Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit’s
Ethernet port
WLNK
 Off - The SU is not connected with a BS
Wireless link status
indication
 Orange on - The SU is connected with and
receives services from the BS (Network
Entry completed). Link Quality is indicated
by LEDs 1-9 as described in Table 3-3.
below.
 Blinking orange - Authentication failed
(LEDs 6, 7 and 8 on)
* After power-up of the ODU, all LEDs illuminate until self-test has completed.
Table 3-3: SAU LINK QUALITY LEDs Functionality
Bar LEDs
SNR
LED 1 (green) is On
Wireless link is established.
LED 2 (green) is On
5dB  SNR < 9dB
LEDs 2-3 (green) are On
10dB  SNR < 14dB
LEDs 2-4 (green) are On
15dB  SNR < 19dB
LEDs 2-5 (green) are On
20dB  SNR < 23dB
LEDs 2-6 (green) are On
SNR  24dB and RSSI < -72dBm
LEDs 2-7 (green) are On
SNR  24dB and RSSI  -72dBm
LEDs 2-8 (green) are On
SNR  24dB and RSSI  -69dBm
LEDs 2-9 (green) are On
SNR  24dB and RSSI  -60dBm
BreezeMAX PRO 5000 CPE
36
Product Manual
Chapter 3 - Commissioning
Aligning the PRO CPE’s Internal Antenna
Table 3-3: SAU LINK QUALITY LEDs Functionality (Continued)
Bar LEDs
SNR
LEDs 2-10 (green) and 9 (red) are On
RSSI  -21dBm (saturation)
LEDs 2-10 Blinking one after the other
During full frequency scan
LEDs 2-10 Blinking as follows: LED 6 lights, after 200ms
LEDs 7 & 5 light, after 200ms LEDs 8 & 4 light, after 200ms
LEDs 9 & 3 light, after 200ms LEDs 10 & 2 light, after 200ms
all the LEDs are extinguished and then the sequence is
repeated.
During Best AU selection process or short scan
3 .3 .2
U sing SAU for Aligning t he PRO CPE's
Ant e nna
The LINK QUALITY bar display on the SAU comprises 9 LEDs:
 The WLNK LED indicates that the wireless link is active, and is lit when the
CPE has completed the Network Entry process.
 LEDs 1 to 8 (green) and 9 (red) indicate the quality of the received signal. The
higher the number of LEDs illuminating, the better the quality of the received
signal.
 If all LEDs, including LED 9 (red) are on, the received signal strength is too
high. This must be avoided, preferably by up-tilting the antenna. As a rule of
thumb, if the CPE is located at a distance of less than 300 meters from the
BTS, it is recommended to up-tilt the antenna by approximately 10° to 15°.
To align the internal antenna using SAU:
Point the antenna toward the general direction of the BTS.
Connect the SAU to the ODU.
Verify that the PWR (power) indication on the SAU is on.
Verify that the WLNK LED indicator is on, indicating that the unit is
synchronized with a BS. If the CPE is not synchronized with a BS, ensure that
all parameters are configured properly. If the unit is still not synchronized with
a BS, improve the quality of the link by changing the direction of the antenna
or by placing the antenna at a higher point or in an alternate location.
BreezeMAX PRO 5000 CPE
37
Product Manual
Chapter 3 - Commissioning
Aligning the PRO CPE’s Internal Antenna
Rotate (and/or tilt if applicable) the ODU until the maximum link quality
reading is achieved. If you encounter prolonged difficulty in achieving the
expected link quality, try to improve the reception quality by placing the ODU
at a higher point or in an alternate location.
NOTE
Ensure that the front of the antenna is always facing the BTS. However, in certain conditions, such
as when the line of sight to the BTS is hampered, better reception may be achieved using a
reflected signal. In this case, the antenna is not necessarily directed toward the BTS.
Secure the ODU firmly to the pole.
BreezeMAX PRO 5000 CPE
38
Product Manual
Chapter 3 - Commissioning
3 .4
Aligning the PRO CPE’s External Antenna
Aligning t he PRO CPE’s Ex t e r na l
Ant e nna
In order to achieve better link quality in units with external antenna, use the
following steps to align the external antenna rather than the CPE itself.
To align the external antenna:
Verify that the the unit is synchronized with a Base Station and ensure that all
parameters are configured properly. If the unit is still not synchronized with a
Base Station, improve the quality of the link by changing the direction of the
antenna or by placing the antenna at a higher or in an alternate location.
Rotate (and/or tilt if applicable) the ODU/antenna until the maximum link
quality (SNR and RSSI) reading is achieved. If you encounter prolonged
difficulty in achieving the expected link quality, try to improve the reception
quality by placing the antenna at a higher point or in an alternate location.
NOTE
Ensure that the front of the antenna is always facing the Base Station. However, in certain
conditions, such as when the line of sight to the Base Station is hampered, better reception may be
achieved using a reflected signal. In this case, the antenna is not necessarily directed toward the
Base Station.
Secure the ODU/antenna firmly to the pole.
CAUTION
In some cases, the antenna may need to be tilted to ensure that the level at which the CPE receives
transmissions from the BTS (and vice versa) is not too high. When the RSSI reading is higher than
-20 dBm, the received signal level is too high (saturation). This must be avoided, preferably by
up-tilting the antenna. As a rule of thumb, if the CPE is located at a distance of less than 300 meters
from the BTS, it is recommended to up-tilt the antenna by approximately 10° to 15°.
BreezeMAX PRO 5000 CPE
39
Product Manual
Chapter 3 - Commissioning
3 .5
Operation Verification
Ope rat ion Ve rific at ion
To verify proper operation of the PRO CPE, examine the LED indicators on the IDU
(see Table 2-5) and the SAU (see Table 3-2).
NOTE
Verifying the correct operation of the ODU using the SAU LEDs is meaningful only after the
configuration and alignment processes are completed, and the unit is synchronized with a BS.
To verify proper connection to the end-user's data equipment, examine the
Ethernet Integrity and Ethernet Activity LEDs of the Ethernet connectors.
To verify data connectivity, from the end-user's PC or from a portable PC
connected to the unit, ping a known device in the network, or connect to the
Internet.
BreezeMAX PRO 5000 CPE
40
Product Manual
Chapter
Operation
Chapter 4 - Operation
I n T his Cha pt e r:
 “Introduction to CPE Management” on page 43
 “Accessing the Web Configuration Server” on page 44
 “Using the Web Configuration Server” on page 45
 “Show All” on page 46
 “Unit Control Parameters” on page 47
 “Registration Parameters” on page 59
 “BST/AU Parameters” on page 63
 “Radio Parameters” on page 67
 “ATPC Parameters” on page 72
 “Performance Monitor” on page 76
 “Service Parameters” on page 79
 “Management Parameters” on page 82
 “Logout” on page 84
 “Parameters Summary” on page 85
BreezeMAX PRO 5000 CPE
42
Product Manual
Chapter 4 - Operation
4 .1
Introduction to CPE Management
I nt roduc t ion t o CPE M a na ge m e nt
The units support the TR-069 CPE WAN Management Protocol (CWMP), allowing
efficient management by an Auto Configuration Server (ACS).
In addition, configuration and performance monitoring of a single unit can be
performed either locally (via the Ethernet port) or remotely using any of the
following options:
 Using a PC/Notebook with an http browser to access the built-in web
configuration server.
 Using TFTP to upload/download a Configuration File.
For local management, the management IP address is 192.168.254.251 with
subnet mask 255.255.255.0.
Remote (over the air) management is done using a WAN management IP address
acquired from a DHCP server as a part of the Network Entry process. The DHCP
server should supply also the IP address of the ACS management station. In the
uplink, the DSCP value of management packets sent by the unit can be
configured only by the remote management system using TR-069 (the default
value is 6).
The Web Configuration Server enables the configuration of all CPE parameters
using a Notebook/PC with a web browser. It also enables downloading of SW files,
control of the running SW version, and downloading/uploading of the
configuration file, enabling simplified and faster configuration process.
The Web Configuration Server also provides a selection of performance monitoring
capabilities, allowing installers and technicians to view information on link quality
and traffic counters. These monitoring capabilities enable performance
verification and problems identification.
To further support local testing, the program also enables temporary control of the
ATPC mechanism.
BreezeMAX PRO 5000 CPE
43
Product Manual
Chapter 4 - Operation
4 .2
Accessing the Web Configuration Server
Ac c e ssing t he We b Configurat ion Se r ve r
To configure parameters using the Web Configuration Server, connect a
PC/Notebook with a web browser to the Ethernet port of the IDU, using a straight
Ethernet cable.
Configure the PC's IP parameters to enable connectivity with the unit. The IP
address of the CPE for local management access is 192.168.254.251. The
Subnet Mask is 255.255.255.0. The recommended IP address for the PC is
192.168.254.250, as this is also the default TFTP Sever IP Address (required
for downloading SW versions and for downloading/uploading configuration
files).
Open a web browser, and connect to http://192.168.254.251. The Enter
Network Password window is displayed. Enter the Username and password
and click OK.
NOTE
The default password is "installer".
The Main window of the Web Configuration Server is displayed, enabling
access to the required parameters configuration and performance monitoring
options.
Figure 4-1: Web Configuration Server - Main Window
BreezeMAX PRO 5000 CPE
44
Product Manual
Chapter 4 - Operation
4 .3
Using the Web Configuration Server
U sing t he We b Configurat ion Se r ve r
The Web Configuration Server view when using a Notebook/PC consists of a
number of menu links (to the left). Clicking on each of them will display the
configuration/status page for the selected menu item, with the applicable content
(configurable parameters/options or status information) in the main area.
Several pages include a page selection bar at the top of the page, enabling
selection between several pages related to the same menu item.
Several pages include a Current Parameters area and a Configured Parameters
area. The Current Parameters area displays the current unit's settings. To change
the settings of the parameters, enter the new settings in the configuration field
and click the Update/Apply button. The change will appear in the Configured
Parameters area and will take effect after performing reset to the unit.
The Web Configuration Server includes the following Menus:
 “Show All” on page 46
 “Unit Control Parameters” on page 47
 “Registration Parameters” on page 59
 “BST/AU Parameters” on page 63
 “Radio Parameters” on page 67
 “ATPC Parameters” on page 72
 “Performance Monitor” on page 76
 “Service Parameters” on page 79
 “Management Parameters” on page 82
 “Logout” on page 84
BreezeMAX PRO 5000 CPE
45
Product Manual
Chapter 4 - Operation
4 .4
Show All
Show All
The Show All page enables viewing all the configurable parameters of the unit. In
addition, the displayed information includes the general hardware and software
properties of the units and relevant status details.
The display includes all the items available upon selecting the Show option for
specific groups of parameters.
BreezeMAX PRO 5000 CPE
46
Product Manual
Chapter 4 - Operation
4 .5
Unit Control Parameters
U nit Cont rol Pa ra m e t e rs
The Unit Control menu includes the following options:
 Show
 Reset Unit
 Change Password
 SW Versions Control
 Configuration Control
 Ethernet Operation (Op) Mode
4 .5 .1
Show
Select this option to view the current values/selected option of applicable
parameters as well as general status information, as follows:
 HW Details
»
CPE Type: CPE Pro SQ
»
CPE Family: Describes the primary chipset of the CPE: Sequans
»
Serial Number: Describes the serial number of the CPE unit. This number
can be used to determine the identity of the subscriber unit by the BTS
operator.
»
MAC Address: This is the unit’s LAN MAC address. The WAN MAC address
is the displayed address +1.
»
MAC Address Control Number (a number computed from the MAC Address
that can be used for verification purposes)
»
Radio Band: Describes the radio band in use (currently only 5 GHz).
»
HW Version: The version of the digital module
»
HW Configuration
BreezeMAX PRO 5000 CPE
47
Product Manual
Chapter 4 - Operation
Unit Control Parameters
»
RF Version: The version of the radio module.
»
CPE Interface Type: 1D (one data port)
»
Radio Type: the receive (Rx) and transmit (Tx) capacity of the radio. 1R/1T
- one receive (Rx) and one transmit (Tx).
»
Antenna Type: Dual slant antenna (embedded)
 Ethernet Port Operation Mode parameters and status:
»
Ethernet Port Auto Negotiation Mode: Enable/Disable
»
Ethernet Port Speed and Duplex
»
Ethernet Down Timeout: Duration (in seconds) after which the system is
up again.
 Operation Mode:
»
IP CS - transparent delivery of IPv4 packets
»
ETH CS transparent delivery of tagged 802.3 packets over Ethernet
 Unit Status: the connectivity status of the unit. Possible statuses are:
»
Searching for Base Station
»
Base station found
»
Not Authorized
»
Not Registered
»
Registered
 SW Versions:
»
SW Boot Version
»
Main SW File Name
»
Main SW Version
»
Shadow SW File Name
BreezeMAX PRO 5000 CPE
48
Product Manual
Chapter 4 - Operation
Unit Control Parameters
»
Shadow SW Version
»
Running from: Main or Shadow
 Upload/Download Parameters:
»
Local TFTP Server IP address: the IP address of the TFTP server from the
LAN side used for SW File/Configuration File download.
»
Remote TFTP Server IP address: the IP address of the TFTP server from the
WAN side used for SW File/Configuration File download.
»
SW File Name: the name in the TFTP server of the SW version to be
downloaded to the unit.
»
Configuration File Upload Name: the name of the configuration file to be
uploaded.
»
Configuration File Download Name: the name of the configuration file to be
downloaded.
4 .5 .2
Re se t U nit
Figure 4-2: Reset Unit Page
The Reset Unit page enables to reset the unit. Click Reset Unit. To avoid
unintentional reset, you will be prompted to confirm the reset request. Changes to
most of the configurable parameters are applied only after reset. Refer to
Section 4.14 for information on which parameters are changeable in run time and
which changes are applied only after reset.
BreezeMAX PRO 5000 CPE
49
Product Manual
Chapter 4 - Operation
4 .5 .3
Unit Control Parameters
Cha nge Pa ssw ord
Figure 4-3: Change Password Page
The Change Password page enables to change the login password. Enter the old
password, the new password and re-enter the new password for confirmation.
Then click Save New Password.
Click Refresh to clear the fields.
NOTE
Notify the administrator of the new password!
Valid passwords: 1 to 20 printable characters, case sensitive.
Default password: installer
BreezeMAX PRO 5000 CPE
50
Product Manual
Chapter 4 - Operation
4 .5 .4
Unit Control Parameters
SW Ve rsions Cont rol
Figure 4-4: SW Versions Control Page
The CPE can contain two SW versions:
 Main: Normally, each time the CPE resets it will reboot using the version
defined as Main.
 Shadow: Normally the Shadow version is the backup version. Each time a new
SW File is downloaded to the CPE, it will be stored as a Shadow version,
replacing the previous Shadow Version.
The typical process of upgrading to a new SW version includes the following steps:
Download the new SW file to the CPE. It will be stored as the Shadow version.
Reset and run the unit from its Shadow version. Note that if the new SW file
was loaded from StarACS, the Run from Shadow operation will be performed
automatically.
If the unit succeeded to complete network entry, the Shadow and Main
versions will be swapped automatically: The currently running version will be
defined as Main and will be used each time the unit reboots. The previous
version is defined now as Shadow.
BreezeMAX PRO 5000 CPE
51
Product Manual
Chapter 4 - Operation
Unit Control Parameters
The CPE functions as a TFTP client, enabling the loading of SW files from a TFTP
server.
The SW Versions Control submenu includes the following fields:
 Main SW File Name: the name of the Main software file.
 Main SW Version: the version of the Main software.
 Shadow SW File Name: the name of the software file in the shadow.
 Shadow SW Version: the version of the software in the shadow.
 Running From: indicates whether the unit is currently running the Main or
the Shadow version.
 Local TFTP Server IP address: the IP address of the TFTP server from the LAN
side used for SW version download. The default TFTP Server IP address is
192.168.254.250. You can enter a new TFTP Server IP address.
NOTE
The same TFTP Server IP Address parameter is used in the SW Download, Configuration File
Download, Country Codes File Upload and Configuration File Upload processes.
 Remote TFTP Server IP address: the IP address of the WAN TFTP server used
for SW version download.
 SW File Name: the name in the TFTP server of the SW version file to be
downloaded to the unit.
The SW Versions Control submenu includes the following control buttons:
 SW Download: click to execute the SW download operation. To avoid
unintentional actions you will be prompted to confirm the request. To perform
the SW download:
The required SW file should be available in the TFTP Server directory in a
PC connected to the unit.
Typically it is recommended to configure the IP address of the PC to
192.168.154.250, which is the default TFTP Server IP address of the unit.
BreezeMAX PRO 5000 CPE
52
Product Manual
Chapter 4 - Operation
Unit Control Parameters
If a different IP address is configured in the PC with the TFTP, configure the
TFTP Server IP Address to the same address.
Enter the name of the SW file (as called in the TFTP server) as the SW File
Name.
Select Perform SW Download and confirm the download request. Wait to
receive a success/failure message.
Following a successful download, the loaded SW version becomes the
Shadow version in the unit.
 Reset and Run from Shadow: select this option to reset the unit and run the
Shadow version after power up. To avoid unintentional actions you will be
prompted to confirm the request.
 Set Running Version as Main: when the unit is running the Shadow version
(after selecting Reset and Run from Shadow) without succeeding to complete
network entry, the versions will not be swapped and the unit will boot from the
Main version after the next reset. Select this option if you want to swap
versions so that the running version will become the Main version and will be
the version to be used after reset. To avoid unintentional actions you will be
prompted to confirm the request.
 Refresh: select this option to clear the fields.
4 .5 .5
Configurat ion Cont rol
Figure 4-5: Configuration Control Page
BreezeMAX PRO 5000 CPE
53
Product Manual
Chapter 4 - Operation
Unit Control Parameters
The Configuration Control submenu enables to define parameters related to
uploading/downloading of configuration files to/from the CPE, and to initiate the
upload/download operation. This submenu also enables downloading of a country
codes file (always named country_codes.xml). The Configuration Control page
includes the following fields:
 Configuration Upload File Name: enter the name in the TFTP server directory
of the configuration file or country code file to be uploaded. A Configuration
File Upload name consists of up to 50 characters. The default Configuration
File Upload name is SU_UPLOAD_CFG. The country code file name is
country_codes.xml. See also “Country Codes” on page 73.
 Configuration Download File Name: enter the name in the TFTP server of the
required configuration file. A Configuration File Download Name consists of up
to 50 characters. The default Configuration File Download Name is
SU_DOWNLOAD_CFG.
 Local TFTP Server IP Address: enter the IP address of the LAN TFTP server. The
default TFTP Server IP address is 192.168.254.250.
NOTE
The same TFTP Server IP Address parameter is used in the SW Download, Configuration File
Download and Configuration File Upload processes.
 Remote TFTP Server IP Address: enter the IP address of the WAN TFTP server.
The default TFTP Server IP address is 192.168.254.250.
 Choose Upload/Download Action: select the action to perform, either upload
or download.
To perform configuration file or country code upload:
Typically it is recommended to configure the IP address of the PC to
192.168.254.250, which is the default TFTP Server IP address of the unit. If a
different IP address is configured in the PC with the TFTP server, configure the
TFTP Server IP address to the same address.
Enter the name of the configuration/country code file (as will appear in the
TFTP server) in the Configuration File Upload Name.
Select Upload in the Choose Upload/Download Action field.
BreezeMAX PRO 5000 CPE
54
Product Manual
Chapter 4 - Operation
Unit Control Parameters
Click Perform Action. Confirm the upload request and wait to receive a
success/failure message.
To perform configuration or country code file download:
Check that the required file is available in the TFTP Server directory in a PC
connected to the unit.
Typically it is recommended to configure the IP address of the PC to
192.168.154.250, which is the default TFTP Server IP address of the unit. If a
different IP address is configured in the PC with the TFTP server, configure the
TFTP Server IP address to the same address.
Enter the name of the configuration file (as called in the TFTP server), or
country code file (as provided by 4Motion) as the Configuration File Download
Name.
Select Download in the Choose Upload/Download Action field.
Click Perform Action. Confirm the download request and wait to receive a
success/failure message.
Following a successful download, reset the unit to apply the new
configuration.
The Configuration Control page includes the following control buttons:
 Perform Action: executes the upload/download action.
 Refresh: clears the screen.
 Set Factory Defaults: click to reset the unit and revert to the default
configuration. To avoid unintentional actions you will be prompted to confirm
the request. All parameters except the Password will revert to the factory
default values.
BreezeMAX PRO 5000 CPE
55
Product Manual
Chapter 4 - Operation
4 .5 .6
Unit Control Parameters
Lic e nc e s
Figure 4-6: License Control Page
Licence control enables loading licence files and view the license parameters.
By default the CPEs are limited from factory to 2 Mb capacity. You can increase
the capacity to 6 Mb or to Unlimited by purchasing a license.
Following are the available licenses:
 From 2 to Unlimited
 From 2 to 6
 From 6 to Unlimited
The License Control page includes the following fields/buttons:
 License Download File Name - the name of the currently used *.lic file.
 Local TFTP Server IP Address: enter the local TFTP server IP address from
which to upload the license file.
 Remote TFTP Server IP Address
 Download Licence File: click to initiate the download procedure
BreezeMAX PRO 5000 CPE
56
Product Manual
Chapter 4 - Operation
Unit Control Parameters
 License Files: list of the valid license files that are loaded to the unit
 License Parameters: the Bandwidth accepted for the unit. In case of
UNLIMITED the value is 0.
The license files can also be uploaded using the TR069 option. The license can be
downloaded to the CPE just by using the SW Upgrade procedure, only that the file
pointed at is a *.lic file. Refer to “SW Versions Control” on page 51.
4 .5 .7
Et he r ne t Ope rat ion (Op) M ode
The Ethernet Port control parameter enables viewing and defining the operation
mode of the Ethernet port.
Figure 4-7: Ethernet Operation Mode Page
The Ethernet Operation Mode page includes the following fields. The read-only
fields display the current configured parameters. The configurable fields enable to
set a different value for these parameters.
 Auto Negotiation: enable/disable Auto Negotiation.
The default is Enable.
 Speed and Duplex: If Auto Negotiation is set to Enable, this field is greyed out.
If set to Disable, this parameters allows selecting one of the following options:
»
10Mbps Half-Duplex
»
10Mbps Full-Duplex
»
100Mbps Half-Duplex
BreezeMAX PRO 5000 CPE
57
Product Manual
Chapter 4 - Operation
»
Unit Control Parameters
100Mbps Full-Duplex
 Ethernet Down Timeout (applicable only in IP CS): Enables to configure
Ethernet downtime, after which it will be up again. The range is from 3
seconds up to 100 seconds.
 Click Apply to save the changes.
BreezeMAX PRO 5000 CPE
58
Product Manual
Chapter 4 - Operation
4 .6
Registration Parameters
Re gist rat ion Pa ra m e t e rs
The Registration menu includes the following sub-menus:
 Show
 User Registration
4 .6 .1
Show
Select this submenu to view the registration parameters (excluding the User
Password that is not shown for security reasons).
Figure 4-8: Registration Show Page
 User Name (Configured and Current): the name of the unit, to be used for
service provisioning. Changes to the User Name parameter are applied only
after reset. Therefore, the actual value may differ from the configured value.
Both the actual and configured values are displayed.
 Organization
 Address
 Country
 Authentication Type: the method of authentication being used to secure the
WiMAX connection.
 Authentication Status: the status of the authentication:
BreezeMAX PRO 5000 CPE
59
Product Manual
Chapter 4 - Operation
Registration Parameters
»
Rejected: the CPE’s authentication request was rejected.
»
Authenticated: the CPE is connected to the BTS.
»
Not Operational: no BTS is found.
 Click Refresh to update the information.
4 .6 .2
U se r Re gist rat ion
Figure 4-9: User Registration Page
The Registration page enables to set the following parameters. After setting the
parameters, click Apply. The changes are saved, and the Registration - Show page
is displayed. A message that informs about rebooting the unit is also, so that the
changes made will take effect.
 User Name: consists of 1 to 32 printable characters, case sensitive.
The default User Name is@WiMax.com, where
 is the actual MAC of the unit. This is a mandatory
parameter; the User Name must be defined during the installation process for
proper authentication and service provisioning.
The new user name is applied only after rebooting the unit.
 Password: the user password (for registration) consists of 1 up to 32 printable
characters, case sensitive. The default password is “quickynikynyoky”.
BreezeMAX PRO 5000 CPE
60
Product Manual
Chapter 4 - Operation
Registration Parameters
The new password is applied only after rebooting the unit.
 Password Confirmation: re-enter the new password when defining one.
 Organization: enter the name of the organization (customer) using the unit.
This parameter is optional, and is intended for optional use by the Network
Management System.
The Organization Name can include up to 32 printable characters.
 Address: use this field to enter the location of the unit. This parameter is
optional, and is intended for optional use by the Network Management
System.
The Address can include up to 32 printable characters.
 Country: use this field to enter the name of the country where the unit is
located. This parameter is optional, and is intended for optional use by the
Network Management System.
The Country name can include up to 12 printable characters.
 Authentication: A security supplicant incorporated into the device supports
Single EAP-TTLSv0 with MSCHAPv2 method according to RFC2759. The
Authentication Mode allows enabling/disabling authentication using the
security supplicant. The available options are:
»
Not Authenticated
»
EAP-TTLS
When EAP-TTLS is configured the CPE will use the configured User
Name/Password with EAP-TTLS protocol for CPE Authentication by AAA. Over
the air data is encrypted using AES-CCM128 as defined in IEEE.802.16-2005.
When Not Authenticated, the CPE will not execute the EAP-TTLS protocol and
will be associated to the ASN GW in non authenticated mode. Over the air data
will not be encrypted.
If the SBC negotiation shows that the connected BS is working in Not
Authenticated mode, the CPE will change automatically to Not Authenticated
BreezeMAX PRO 5000 CPE
61
Product Manual
Chapter 4 - Operation
Registration Parameters
mode and will complete the network entry without EAP-TTLS authentication
process.
The default is EAP-TTLS.
BreezeMAX PRO 5000 CPE
62
Product Manual
Chapter 4 - Operation
4 .7
BST/AU Parameters
BST /AU Pa ra m e t e rs
The quest for load sharing together with the desire to create best throughput
conditions for the CPE created the need for the Best BS feature, to enable an CPE
to connect to the best BS in its neighborhood.
The CPE scans a set of frequencies (see “Radio Parameters” on page 67) searching
for BSs it can communicate with. Each BS in the network is configured with a
unique BS ID. The BS ID parameters in the CPE define a set of BS IDs, and the
CPE is allowed to communicate only with BSs whose BS ID is included in the BS
IDs range defined by the applicable parameters. Each of the BSs with which the
CPE can communicate (perform initial phase of network entry) is given a quality
mark based on the quality of the signal at which it is received by the CPE. At the
end of the scanning period, the CPE reaches a Best BS decision according to the
information gathered. The BS with the highest quality mark is selected as the Best
BS, and the CPE will immediately try to associate with it at the relevant
frequency/bandwidth.
The range used for scanning is defined by the BS ID and BS ID Mask parameters.
The initial range can be limited by defining a preferred range of BSs, and selecting
the best BS in the preferred range. If no device is found in the preferred range, the
CPE will scan the entire range.
A Mobility Mode parameter enables supporting optimal performance after loosing
connectivity to the BS according to the expected mobility of the CPE: A Mobile
CPE is expected to move among different BSs, while a Nomadic CPE is typically
stationary although it may also be moved to the coverage area of a different BS.
If a Nomadic CPE loses communication with the selected BS, it will continue
searching for it for 4 minutes. If not found within 4 minutes, the CPE will scan the
frequencies from the discrete frequencies list and if it finds a preferred BS within
these frequencies it will associate with it. If the CPE does not find any BS at this
stage or cannot associate with any of the BSs found, it will move on to the Full
Scan.
The same process will be executed also for a Mobile CPE.
The same process will be executed following a reset of the CPE, with the exception
that the CPE retries connecting to the last connected BS for 2 minutes in case of
reset in the following situations:
»
BS is preferred
»
Preferred mask is not set
BreezeMAX PRO 5000 CPE
63
Product Manual
Chapter 4 - Operation
BST/AU Parameters
In case of loosing the link connection, the CPE will:
»
Wait 4 minutes if BS is preferred, or preferred mask is not set
»
Go directly to scanning if BS is not preferred and mask is set
Figure 4-10: BST/AU Page
The BST/AU page includes the following parameters:
 Best BST/AU Parameters and Best BST/AU Table:
BreezeMAX PRO 5000 CPE
64
Product Manual
Chapter 4 - Operation
»
BST/AU Parameters
Configured Best BS ID: the configured Preferred BST/AU ID. Together with
the BS ID Mask, it is used to define the range of BSs that can communicate
with the unit.
The BS ID comprises 6 octets of up to 3 digits each, where the range of
each group is 0 to 255.
The default BS ID is 0.0.0.0.0.0
»
Current Best BS ID
»
Selected Best BS ID
»
Preferred Best BS ID
»
Current Preferred BS ID
If a BS ID is set on the preferred BS and the mask is
255.255.255.255.255.255 and the CPE finds it in the discrete frequency
list or in the full range, it will immediately connect to it.
 Selected BST/AU Parameters:
»
Selected BST/AU ID: The BST/AU ID to which the CPE is currently
connected.
»
Selected Rx Frequency: The Rx Frequency of the BTS to which the CPE is
currently connected.
»
Selected Best BS RSSI: The Rx RSSI of the BTS to which the CPE is
currently connected.
»
Selected Best BS SNR (dB): The Rx SNR of the BTS to which the CPE is
currently connected.
»
Selected BW: The bandwidth of the BTS to which the CPE is currently
connected.
 Best BST/AU Table: displays the following details for each of the BS(s) found
during the scanning process:
»
BS ID
BreezeMAX PRO 5000 CPE
65
Product Manual
Chapter 4 - Operation
BST/AU Parameters
»
Rx Frequency (KHz)
»
SNR (dB)
»
RSSI (dBm)
»
Bandwidth
 BST/AU and Preferred BST/AU Parameters
»
BST/AU ID
»
BST/AU ID Mask
»
Preferred BST/AU ID
»
Preferred BST/AU ID Mask
»
Mobility Mode: enables defining the expected mobility of the CPE: Nomadic
or Mobile.
The default is Nomadic.
After configuring the parameters, click Apply to save your changes.
 Preferred BS Loss - Timeout before trying to connect to a preferred BS. This
value should vary between 30 minutes and 6 hours increasing dynamically by
30 minutes every time the timer expires, until reaching 6 hours.
»
Min. Re-scan Timeout (min): (default 30)
»
Max. Re-scan Timeout (min): (default 360)
After configuring the parameters, click Apply to save your changes.
BreezeMAX PRO 5000 CPE
66
Product Manual
Chapter 4 - Operation
4 .8
Radio Parameters
Ra dio Pa ra m e t e rs
The Radio Parameters page includes the following options:
 Show
 Frequency Scanning
 Antenna Selection
4 .8 .1
Show
The Show page displays the Frequency and Bandwidth selected by the scanning
mechanism.
Figure 4-11: Radio - Show Page
4 .8 .2
Fre que ncy Sc a nning
The Frequency Scanning page enables viewing and updating the set of frequencies
to be used during the scanning process. The list of frequencies that participate in
the scanning process includes a set of frequencies belonging to the scanning
range and/or a set of up to 10 discrete frequencies.
The scanning range is defined by Start Rx Frequency, End Rx Frequency,
Scanning Main Step and Intermediate Steps. The set of frequencies to be scanned
is defined as follows:
The “Main Frequencies” are defined by the Start Frequency and Main Step, using
the formula F(N) =Start Frequency + N*Main Step; 
F(1) = Start Frequency + Main Step, F(2) = Start Frequency +2*Main Step,...
End Frequency is the upper limit.
BreezeMAX PRO 5000 CPE
67
Product Manual
Chapter 4 - Operation
Radio Parameters
The Intermediate Steps can be used to define additional frequencies using a finer
resolution. The intermediate steps are defined as follows:
NOTE
In the current version, intermediate steps are disabled.
Table 4-1: Intermediate Steps
Step
Effect on scanned frequencies set when Step is Enabled
B0
Scan Start Frequency: Start Frequency is added to the set of “Main Frequencies”
B1
Intermediate Step=125 KHz: All intermediate frequencies defined by “Main Frequency” +
125 KHz are added to the scanning set
B2
Intermediate Step=250 KHz: All intermediate frequencies defined by “Main Frequency” +
250 KHz are added to the scanning set
B3
Intermediate Step=375 KHz: All intermediate frequencies defined by “Main Frequency” +
375 KHz are added to the scanning set
B4
Intermediate Step=500 KHz: All intermediate frequencies defined by “Main Frequency” +
500 KHz are added to the scanning set
B5
Intermediate Step=625 KHz: All intermediate frequencies defined by “Main Frequency” +
625 KHz are added to the scanning set
B6
Intermediate Step=750 KHz: All intermediate frequencies defined by “Main Frequency” +
750 KHz are added to the scanning set
B7
Intermediate Step=875/1250 KHz: All intermediate frequencies defined by “Main
Frequency” + 1250 KHz are added to the scanning set.
For example, if steps B0, B1 and B4 are enabled and all other steps are disabled,
the scanned frequencies are: Start Frequency, Start Frequency + 125 KHz, Start
Frequency + 500 KHz, Start Frequency +N*Main Step, Start Frequency +N*Main
Step + 125 KHz, Start Frequency +N*Main Step + 500 KHz (N=1, 2,...). End
Frequency is the upper limit for the scanned frequencies.
In addition, the Discrete Frequencies option enables defining up to 10 discrete
frequencies to be used in the scanning process in addition to the frequencies
defined by the Frequency Scanning parameters.
BreezeMAX PRO 5000 CPE
68
Product Manual
Chapter 4 - Operation
Radio Parameters
Figure 4-12: Frequency Scanning Page
The Frequency Scanning menu includes the following fields:
 Scanning Table: displays the list of all current frequencies that participate in
the full scanning process. Following the Full Scanning Table, the Best BS
Scanning Table displays all the frequencies associated with BSs that are
included in the current Best BS Table.
BreezeMAX PRO 5000 CPE
69
Product Manual
Chapter 4 - Operation
Radio Parameters
 Start Rx Frequency (KHz): the lowest frequency in the range of frequencies to
be scanned (in KHz).
The available values depend on the radio band of the unit.
 End Rx Frequency (KHz): the highest frequency in the range of frequencies to
be scanned (in KHz).
The available values depend on the radio band of the unit.
 Scanning Main Step (MHz): the Main Scanning Step that together with the
Intermediate Scanning Steps define the frequencies to be scanned between the
Start and End Rx Frequencies.
The main steps can be 2.5 MHz or 5 MHz. The default is 2.5 MHz.
 Scanning Intermediate Steps (KHz): the Intermediate Scanning Steps that
together with the Main Scanning Step define the frequencies to be scanned
between the Start and End Rx Frequencies.
The Intermediate Scanning Steps include 8 Steps that define the intermediate
scanning steps as described above. The default is Enable for the B0 Start
Frequency Scan.
NOTE
In the current version, intermediate steps are disabled.
 Bandwidth: enables to select either a specific bandwidth (according to the
options supported by the unit) or scan all supported bandwidths (Auto).
The default is Auto mode.
To change the bandwidth, select the required bandwidth from the list and click
Apply.
 Discrete Frequencies: enables editing the list of discrete frequencies that will
be included in the Frequency Scanning Table. If no discrete frequency has
been added, N/A will be displayed. To delete a discrete frequency from the list,
first selecting the frequency to be deleted and click Delete select. The Delete
select button is available only if at least one discrete frequency is added.
BreezeMAX PRO 5000 CPE
70
Product Manual
Chapter 4 - Operation
Radio Parameters
 Delete All Discrete Frequencies: to delete all discrete frequencies, click on
Delete All.
 Discrete Scanning Frequencies: enables to enter discrete frequencies, as
follows:
»
Update List of Discrete Frequencies: Enter a list of up to 10 discrete
frequencies in steps of 2.5MHz, separated by commas (no space). This list
will replace the current list of discrete frequencies.
»
Add One Discrete Frequency: Enter one frequency to be added to the
current list of discrete frequencies.
 Update Scanning Table: select this option to update the frequency scanning
table in run time (without resetting the unit).
 Clear Best BS Table: select this option to clear the current Best BS Table.
Typically this should be done prior to initiating a full scanning process (see
below).
 Force Full Scanning: select this option to initiate a full scanning process. The
BS table is cleared automatically.
4 .8 .3
Ant e nna Se le c t ion
Figure 4-13: Antenna Selection Page
The Antenna Selection page enables viewing the parameters of the integrated and
external antennas. The following parameters are displayed:
 Radio Status
 Antenna Gain: enables configuration of the external antenna gain (shown only
if the CPE is configured with an external antenna). Enter the gain value for the
external antenna and click Apply. The message “Antenna Param Set, done!” is
displayed. This operation requires a CPE reboot in order for the change to take
effect.
BreezeMAX PRO 5000 CPE
71
Product Manual
Chapter 4 - Operation
4 .9
ATPC Parameters
AT PC Pa ra m e t e rs
In regular operation, the level of the signal transmitted by the CPE is controlled by
the Adaptive Transmission Power Control (ATPC) mechanism of the serving BS.
The ATPC page enable temporary control of the signal transmitted by the CPE. It
is intended for test purposes only.
These settings will not be saved and will automatically return to original values as
received from the BS when the unit resets or upon closing the web interface.
The ATPC menu includes the following sub-menus:
 Show
 ATPC
4 .9 .1
Show
Select this option to view the current Multirate and ATPC parameters:
 Last Tx Rate: the last detected transmission rate
 Optimal Rx Rate: the transmission rate best suited to the connection
 ATPC: The current status (Enabled/Disabled) of the ATPC mechanism
 Tx Power: the transmission power level
 Current Country Code Data: the country code that is currently used.
Figure 4-14: ATPC Show Page
BreezeMAX PRO 5000 CPE
72
Product Manual
Chapter 4 - Operation
4 .9 .2
ATPC Parameters
AT PC
Figure 4-15: Multi rate and ATPC Parameters Page
From the ATPC page, you can enable/disable the ATPC mechanism and select
your country code.
4.9.2.1
ATPC
To enable/disable the ATPC mechanism:
Select Disable to temporarily disable ATPC for testing purposes. You will be
prompted to enter the requested Tx Power. The available range depends on
unit type/radio band.
IMPORTANT
The maximum Tx power may vary depending on the country code applied and on applicable
regulations.
The default Tx Power is the last power level used before the ATPC algorithm
was disabled.
Click Apply.
Upon completing the test, enable ATPC to resume normal operation. If not
enabled manually, ATPC will be enabled automatically after the next reset or
when closing the web interface.
4.9.2.2
Country Codes
The country codes can be configured using two methods:
BreezeMAX PRO 5000 CPE
73
Product Manual
Chapter 4 - Operation
ATPC Parameters
 Selecting from a set of default country codes that appear in the ATPC window
as described below.
 Uploading a country codes file as described in the Configuration Control (see
“Configuration Control” on page 53.
The Current Country Code Data field displays the country code that is currently
used. After performing reset to the unit, the configured country code becomes the
current country code.
The following are the available country codes:
Table 4-2: Country Codes
BreezeMAX PRO 5000 CPE
Country Code
Frequency Range (MHz)
4.9 GHz Universal
4900-5350
4.9 GHz FCC
4940-4990
4.9 GHz Japan A
4900-5000
4.9 GHz Japan B
5030-5091
5.3 GHz ETSI
5150-5350
5.2 GHz ETSI
5150-5350
5.2 GHz FCC
5150-5350
5.3 GHz FCC
5250-5350
5.1-5.3 GHz FCC
5150-5350
5.1 GHz FAA
5090-5150
5.4 GHz Universal
5470-5900
5.9 GHz Universal
5900-5950
5.4 GHz ETSI
5470-5725
5.8 GHz ETSI
5725-5875
5.4 GHz FCC
5470-5725
5.8 GHz FCC
5725-5875
5.4 GHz Australia A
5490-5585
5.4 GHz Australia B
5655-5725
5.8 GHz Australia
5730-5840
5.8 GHz UK
5725-5845
74
Product Manual
Chapter 4 - Operation
ATPC Parameters
To select a country code:
IMPORTANT
The selected Country Code must comply with applicable local radio regulations.
The selected Country Code may affect the maximum Tx power and also the system performance.
Select the required country code from the list and reset the unit to apply the new
country code.
BreezeMAX PRO 5000 CPE
75
Product Manual
Chapter 4 - Operation
4 .1 0
Performance Monitor
Pe rfor m a nc e M onit or
The Performance Monitor Page enables viewing performance monitoring of link
quality, and Ethernet counters, and enables to set the monitoring intervals. The
CPE collects data on a regular basis and is able to deliver the data to the Access
Control Server NMS (Network Management Station) upon request.
The Performance Monitor menu includes the following options:
 Link Quality Counters Page
 Ethernet Counters
4 .1 0 .1
Link Qua lit y Count e rs Pa ge
The Link Quality On-Line Display table displays read-only information related to
the quality of the link between the CPE and the BTS. The display is updated every
2 seconds based on histograms/counters collected during this period.
Figure 4-16: Link Quality On-line Display Page
The Link Quality Counters page displays the following counters:
 Current Fec Code
 CINR (dB): the average Carrier to Interference and Noise Ratio of the signal
 CINRStd (dB)
 CINR Reuse 1 (dB)
BreezeMAX PRO 5000 CPE
76
Product Manual
Chapter 4 - Operation
Performance Monitor
 CINRStd Reuse 1 (dB)
 CINR Reuse 3 (dB)
 CINRStd Reuse 3 (dB)
 RSSI
 RSSIStd
 Last Tx Power (dBm)
 UL Fec Code
4 .1 0 .2
Et he r ne t Count e rs
The Ethernet On-Line Counters page displays RX and Tx levels for the Ethernet
connection.
Figure 4-17: Ethernet Counters Page
The Ethernet On-Line Counters table displays a continuously updated list of the
traffic counters. The display is updated every 2 seconds based on counters
collected during this period. The displayed counters include the following for each
port (LAN/WAN) and each direction (TX/RX):
 Bit Rate
 Packet Rate
BreezeMAX PRO 5000 CPE
77
Product Manual
Chapter 4 - Operation
Performance Monitor
 Total Bytes
 Total Packets
Rate counts are the average rate (Bytes/Packets per second) for the last
measurement interval (2 seconds).
Total counts are the accumulated number of Bytes/Packets since the last unit
reset or the last Counters Reset.
BreezeMAX PRO 5000 CPE
78
Product Manual
Chapter 4 - Operation
4 .1 1
Service Parameters
Se r vic e Pa ra m e t e rs
The Service Parameters page enables viewing and setting the service related
parameters configured via the BTS. To edit parameters, select the Change Service
Parameters page.
Figure 4-18: Service Page - IP CS Mode (Show Parameters)
Figure 4-19: Change Service Parameters - Ethernet CS Mode
NOTE
The Operation mode cannot be modified from the Change Service Parameters page.
The Service Parameters page displays the following:
For IP CS Mode:
 Service Line Count: this is the number of configured services and corresponds
to the number of service rules in the Service Definition table.
BreezeMAX PRO 5000 CPE
79
Product Manual
Chapter 4 - Operation
Service Parameters
 Operation Mode: displays the convergence sublayer (CS) in the wireless access
network: IP CS (DSCP based classification) or Ethernet CS (VLAN based
classification).
 Service Definition table: displays the Service Rules to be used for handling the
relevant classifiers (VLAN/DSCP) of packets processed by the units. For each
service rule, the following parameters are displayed:
»
Service ID: up to 8 non-overlapping Service Rules can be defined via the
BTS.
»
VLAN ID: from 0 to 4095
»
VLAN Priority: from 0 to 7
»
DSCP Start Value: from 0 to 63
»
DSCP Stop Value: from 0 to 63
»
DSCP Marking: Enabled/Disable:
»
Access VLAN: From 0 to 4095 or 4096 (Transparent). Transparent is used
to allow untagged packets.
When enabled, the DSCP value of a packet arriving from the Ethernet port
must be 0 (otherwise it will be discarded). Before forwarding to the wireless
port the 0 DSCP value will be replaced by the defined DSCP value and the
VLAN tag will be removed. For packets with this DSCP value arriving from
the wireless port, the defined VLAN tag will be added before forwarding it to
the Ethernet port (without changing the DSCP value).
If DSCP Marking is disabled, a packet with the defined VLAN tag (VLAN ID
and Priority) will be forwarded to the wireless port after removal of the
VLAN tag. The DSCP value of these packets is the DSCP configured (the
packet will be forwarded regardless of its DSCP value). For packets with the
configured DSCP value arriving from the wireless port, the defined VLAN
tag (VLAN ID and Priority) will be added before forwarding to the Ethernet
port.
BreezeMAX PRO 5000 CPE
80
Product Manual
Chapter 4 - Operation
Service Parameters
For Ethernet CS mode:
 Access VLAN: From 0 to 4095 or 4096 (Transparent). Transparent is used to
allow untagged packets. In the Change Service Parameters page, you can
change the Access VLAN as required. Click Modify to apply the changes.
 Operation Mode: displays the convergence sublayer (CS) in the wireless access
network: IP CS (DSCP based classification) or Ethernet CS (VLAN based
classification). The operation mode is detected automatically.
For additional information on service configuration, refer to the BreezeMAX
Extreme System Manual.
BreezeMAX PRO 5000 CPE
81
Product Manual
Chapter 4 - Operation
4 .1 2
Management Parameters
M a na ge m e nt Pa ra m e t e rs
The Management Page enables viewing the parameters related to remote (over the
air) management of the device, and configure the parameters of the DHCP client.
The Management Parameters menu includes the following options:
 Management Parameters
 DHCP Client Configuration
4 .1 2 .1
M a na ge m e nt Pa ra m e t e rs
Figure 4-20: Management Page
The Management page enables viewing the parameters related to remote (over the
air) management of the device and to set the DSCP classifier.
The following parameters are displayed:
 Factory Defaults DSCP Classifier
 Actual Used DSCP Classifier: the DSCP classifier used when the CPE is
connected. When the CPE is not connected, the value is N/A.
 Configured DSCP (to change, enter a value and click Apply). Range 0-63;
Default 6
 Management IP Address (acquired from a DHCP server during Network Entry)
BreezeMAX PRO 5000 CPE
82
Product Manual
Chapter 4 - Operation
Management Parameters
 eCPE Manager IP Address (acquired from a DHCP server, or Not Available)
 eCPE Manager Connection Status (Up, Down or Not Connected)
4 .1 2 .2
DH CP Clie nt Configurat ion
Figure 4-21: Dhcp Client Configuration
The DHCP Client Configuration page enables viewing and updating the
parameters of the DHCP client.
 Dhcp Client
 Client IP Address
 Network Mask
 Default Gateway IP Address
 TR069 Server IP Address
By default, DHCP Client is enabled (IP address allocated by DHCP), therefore
parameters cannot be modified.
To change the parameters in order to have static IP address for the CPE
management, select the Disable option, modify the values and click Apply.
NOTE
The DHCP Client can be set to disable only in ETH-CS service
BreezeMAX PRO 5000 CPE
83
Product Manual
Chapter 4 - Operation
4 .1 3
Logout
Logout
To log out, click on the Logout menu. The following window is displayed:
Figure 4-22: Logout Page
Click on the Logout button. The Login page is displayed.
BreezeMAX PRO 5000 CPE
84
Product Manual
Chapter 4 - Operation
4 .1 4
Parameters Summary
Pa ra m e t e rs Sum m a r y
Table 4-3: CPE Parameters Summary
Parameter
Range
Default
Run-Time
Updated
Password
Up to 20 printable characters,
case sensitive
installer
No
Local TFTP Server IP Address
IP address
192.168.254.250
Yes
 Upload
Upload
No
Unit Control Parameters
Configuration Upload File
Name
Configuration Download File
Name
Choose Upload/Download
Action
 Download
Licences
 From 2 to Unlimited
Licence.lic
 From 2 to 6
 From 6 to Unlimited
SW File Name
Ethernet Port Auto Negotiation
Yes
 Disable
Enable
No
 Enable
Ethernet Port Speed and
Duplex
 10Mbps Half-Duplex
No
 10Mbps Full-Duplex
 100Mbps Half-Duplex
 100Mbps Full-Duplex
Registration Parameters
User Name
1 to 32 printable characters,
case sensitive
@Wi
Max.com
No
Password
1 to 32 printable characters,
case sensitive
quickynikynyoky
No
Organization
Up to 32 printable characters
No
Address
Up to 32 printable characters
Yes
BreezeMAX PRO 5000 CPE
85
Product Manual
Chapter 4 - Operation
Parameters Summary
Table 4-3: CPE Parameters Summary
Parameter
Range
Default
Country
Up to 12 printable characters
Authentication
 Not Authenticated
Run-Time
Updated
Yes
EAP TTLS
Yes
 EAP TTLS
BS ID Parameters
BST/AU ID
6 octets of up to 3 digits each.
Each group range is 0-255.
0.0.0.0.0.0
Yes
BST/AU ID Mask
6 octets of up to 3 digits each.
Each group range is 0-255.
0.0.0.0.0.0
Yes
Preferred BST/AU ID
6 octets of up to 3 digits each.
Each group range is 0-255.
0.0.0.0.0.0
Yes
Preferred BS ID Mask
6 octets of up to 3 digits each.
Each group range is 0-255.
0.0.0.0.0.0
Yes
Mobility Mode
 Nomadic
Nomadic
Yes
Per country code
Yes 
(after Update
Scanning Table)
Per country code
Yes 
(after Update
Scanning Table)
2.5 MHz
Yes 
(after Update
Scanning Table)
Auto
Yes
Enable
Yes
Last power used by
ATPC
Yes
 Mobile
Radio Parameters
Start Rx Frequency (KHz)
Per country code
Resolution for all bands is
0.125 MHz
End Rx Frequency (KHz)
Per country code
Resolution for all bands is
0.125 MHz
Scanning Main Step (MHz)
 2.5 MHz
 5 MHz
Set Bandwidth to Scan
 5 MHz
 10 MHz
 Auto
Multirate and ATPC Parameters
ATPC
 Enable
 Disable
Set Tx Power
BreezeMAX PRO 5000 CPE
-26 to 21
86
Product Manual
Chapter 4 - Operation
Parameters Summary
Table 4-3: CPE Parameters Summary
Parameter
Range
Default
Run-Time
Updated
0-63
No
Management
Configured DSCP Classifier
BreezeMAX PRO 5000 CPE
87
Product Manual
Appendix
Troubleshooting
Appendix A - Troubleshooting
I n T his Appe ndix :
 “CPE Troubleshooting” on page 90
BreezeMAX PRO 5000 CPE
89
Product Manual
Appendix A - Troubleshooting
A.1
CPE Troubleshooting
CPE Trouble shoot ing
Refer to the BreezeMAX Troubleshooting Guide for additional information on
troubleshooting.
Problem and Indication
Possible Cause
Corrective Action
Power Failure: None of the
IDU LEDs illuminate after
connecting to power
Mains power problem
Verify mains power availability on the power outlet to
which the power supply is connected. Try using a
different outlet.
Mains power connection
problem
Verify that the AC jack of the power cord is
connected properly to the unit.
Verify that the AC plug of the power cable is
connected properly to the mains power outlet.
Unit failure
Replace the IDU.
IDU-ODU connection
problem: None of the SAU’s
indicators illuminate
IDU-ODU connection
problem
Verify that the IDU-ODU cable is connected
properly.
Unit failure
Try replacing the IDU. If the problem persists, try
replacing the IDU-ODU cable. If the problem
persists, try replacing the ODU.
When connected to the
data equipment, the
Ethernet Integrity Indicator
(green LED) is off, and/or
the Ethernet Activity
Indicator (yellow LED) does
not blink when there should
be traffic on the Ethernet
port.
Wrong type of Ethernet
cable or faulty cable.
If connected directly to PC-use a straight cable.
Otherwise-use a crossed cable. If the problem
persists, try replacing the cable.
BreezeMAX PRO 5000 CPE
If a hub or switch is installed between the PC and
the CPE, verify first the Ethernet connection integrity
between the hub/switch and the PC by checking the
Ethernet LEDs at the hub/switch and at the PC's
NIC card. If not ok, try replacing the cable.
IDU-ODU cable problem.
Verify that the IDU-ODU cable is in order and
connected properly. Using SAU, verify that PWR
LED is on and ALRM LED is off.
Unit failure
Try replacing the IDU. If the problem persists, try
replacing the IDU-ODU cable. If the problem
persists, try replacing the ODU.
90
Product Manual
Appendix A - Troubleshooting
CPE Troubleshooting
Problem and Indication
Possible Cause
Corrective Action
The Ethernet Activity and/or
Integrity LEDs are on, but
no management access
using Telnet or web
browser, and the unit does
not respond to ping.
Wrong IP configuration
Make sure that the PC is on the same subnet as the
unit. The unit's IP address for management
purposes is 192.168.254.251, and the subnet mask
is 255.255.255.0.
Wrong Ethernet port
operation mode
Make sure that the speed and duplex settings in the
PC match the configuration in the unit. The default
operation mode is Auto Negotiation, and supported
speeds are 10/100 Mbps, Full or Half Duplex.
ARP table in the PC
contains a wrong MAC
address for the
192.168.254.251 IP
address (due to a recent
connection to another
CPE).
Perform arpV-d at the DOS command prompt to
clear the ARP table, and retry the Telnet command
to the unit.
Bridging table in CPE is full
(expected when Number of
Supported Devices,
configurable from the Base
station's side, is set to a
small number.
Reset the CPE to clear the table and retry the Telnet
command to the unit.
Configuration problem
Verify proper configuration of Frequency Scanning
parameters.
Scanning failed and/or
Base Station not found:
None of the LINK QUALITY
LEDs illuminate.
Verify proper configuration of BS ID parameters.
If proper configuration parameters are not known,
press the RESET button for more than 5 seconds to
activate the factory default configuration
Poor link quality
Try changing the location of the unit/antenna to
improve link quality using the LINK QUALITY LEDs.
Signal is too strong:All LINK
QUALITY LEDs, including
the red LED are on
Signal is too strong-may
cause saturation.
Change the location/direction of the unit/antenna to
reduce signal strength using the LINK QUALITY
LEDs.
Authentication Failure: LED
1 (orange) of the LINK
QUALITY bar blinks.
Authentication problem
Enter User Name and User Password and reset the
unit. If the problem persists, contact the operator.
BreezeMAX PRO 5000 CPE
91
Product Manual
Glossary
Glossary
AAA
Authentication, Authorization, and Accounting (pronounced "triple a."). A system (or
several systems) that controls what resources users have access to, and keeps track of
the activity of users over the network.
ACS
Auto Configuration Server. A CPE management system supporting secure
auto-configuration as well as other CPE management functions.
AES-CCM
Advanced Encryption Standard - Counter mode with Cipher-block chaining Message
authentication code.
Counter mode with Cipher-block chaining Message authentication code (CCM) is an
encryption protocol in the 802.11i standard. The CCM protocol (CCMP) is based upon
the CCM mode of the AES encryption algorithm and utilizes 128-bit keys.
APD
Automatic Platform Detection. A mechanism that dtects the wireless link protocol used
by the Base Station, enabling automatic selection of the operation mode to be used
Subscriber Unit.
ARP
Address Resolution Protocol. Internet protocol used to map an IP address to a MAC
address. Defined in RFC 826
ATPC
Automatic Transmit Power Control
AWGN
Additive white Gaussian noise, also known as white noise, contains equal energy per
frequency across the spectrum of the noise employed.
BPSK
Binary Phase-Shift Keying. A data transfer technique. BPSK transmits data using two
phase modulation signals, one phase representing a binary one, and the other
representing a binary zero. The signal is divided into bits; their status is determined by
the preceding wave. If the wave changes, for example, the signal is reversed.
BS
Base Station. The WiMAX BS is an entity that implements the WiMAX MAC and PHY in
compliance with the IEEE 802.16e standard. A BS operates on one frequency
assignment, and incorporates scheduler functions for uplink and downlink resources.
BTS
Base Transceiver Station. A wireless network element that provides the radio interface
of the network. The BTS comprises the radio transmission and reception devices, and
also manages the signal processing related to the air interface.
BWA
Broadband Wireless Access
CF
Compact Flash. A popular memory card that uses flash memory to store data on a very
small card.
CINR
Carrier-to-Interference plus Noise Ratio (expressed in dB)
CLI
Command Line Interface. A user interface where the user sees the command line on
the monitor and a prompt that is waiting to accept instructions from the user. The user
types in the command, the computer acts on that command and then issues a new
prompt for the next instruction from the user.
CPE
Customer Premise Equipment. Communications equipment that resides on the
customer's premises.
CPU
Central Processing Unit
BreezeMAX PRO 5000 CPE
93
Product Manual
Glossary
CRC
Cyclical Redundancy Check. A common technique for detecting data transmission
errors, in which the frame recipient calculates a remainder by dividing frame contents
by a prime binary divisor and compares the calculated remainder to a value stored in
the frame by the sending equipment.
CS
Convergence Sublayer. Particular protocols that are responsible for gathering and
formatting higher layer information so it can be processed by the lower layers.
CSMA/CD
Carrier Sense Multiple Access with Collision Detection. Media-access mechanisms
wherein devices ready to transmit data first check the channel for a carrier. If no carrier
is sensed for a specific period of time, a device can transmit. If two devices transmit at
once, a collision occurs and is detected by all colliding devices. This collision
subsequently delays retransmissions from those devices for some random length of
time. Ethernet and IEEE 802.3 use CSMA/CD access.
CW
Continuous Wave. An unmodulated RF signal.
CWMP
CPE WAN Management Protocol. See also TR-069.
DHCP
Dynamic Host Configuration Protocol. A protocol for dynamically assigning IP
addresses from a pre-defined list to nodes on a network. Using DHCP to manage IP
addresses simplifies client configuration and efficiently utilizes IP addresses.
DL
Down Link
DSCP
Differentiated Service Code Point, AKA DiffServ: An alternate use for the ToS byte in IP
packets. Six bits of this byte are being reallocated for use as the DSCP field where
each DSCP specifies a particular per-hop behavior that is applied to the packet.
EAP
Extensible Authentication Protocol, A protocol used between a user station and an
authenticator or authentication server. It acts as a transport for authentication methods
or types. It, in turn may be encapsulated in other protocols, such as 802.1x and
RADIUS. EAP is defined by RFC 2284.
EAP-TTLS
Extensible Authentication Protocol-Tunneled Transport Layer Service. A type of mutual
authentication protocol where just the server sends a digital certificate to identify itself
to the clients.
EMC
Electro-Magnetic Compatibility. The capability of equipment or systems to be used in
their intended environment within designed efficiency levels without causing or
receiving degradation due to unintentional EMI (Electro Magnetic Interference). EMC
generally encompasses all of the electromagnetic disciplines.
ETSI
European Telecommunications Standards Institute. A non-profit organization producing
voluntary telecommunications standards used throughout Europe, some of which have
been adopted by the EC as the technical base for Directives or Regulations.
FCC
Federal Communications Commission. A U.S. government agency that supervises,
licenses, and controls electronic and electromagnetic transmission standards.
FEC
Forward Error Correction. A method of communicating data that can correct errors in
transmission on the receiving end. Prior to transmission, the data is put through a
predetermined algorithm that adds extra bits specifically for error correction to any
character or code block. If the transmission is received in error, the correction bits are
used to check and repair the data.
BreezeMAX PRO 5000 CPE
94
Product Manual
Glossary
FFT
Fast Fourier Transform. An algorithm for converting data from the time domain to the
frequency domain; often used in signal processing.
FIPS
Federal Information Processing Standards. The Federal Information Processing
Standard (FIPS) Publication 140-2 1, called Security Requirements for Cryptographic
Modules, is a United States security standard used to certify cryptographic modules.
FTP
File Transfer Protocol. A protocol for exchanging files over the Internet. FTP uses the
Internet's TCP/IP protocols to enable data transfer.
GUI
Graphical User Interface. In a GUI operating system, the user responds to graphic
images on the screen instead of typing in commands in response to a prompt.
HTTP
HyperText Transfer Protocol. The protocol used to transmit and receive data over the
World Wide Web.
IDU
Indoor Unit
IEEE
Institute of Electrical and Electronics Engineers. IEEE (pronounced I-triple-E) is an
organization composed of engineers, scientists, and students. The IEEE is best known
for developing standards for the computer and electronics industry. In particular, the
IEEE 802 standards for local-area networks are widely followed.
IEEE 802.3
A Local Area Network protocol suite commonly known as Ethernet. Ethernet uses
Carrier Sense Multiple Access bus with Collision Detection CSMA/CD. This method
allows users to share the network cable. However, only one station can use the cable at
a time. A variety of physical medium dependent protocols are supported.
IEEE 802.16
Also known as WIMAX. A group of broadband wireless communications standards for
metropolitan area networks (MANs) developed by a working group of the IEEE.
IEEE 802.16e
802.16e, also known as 802.16-2005, is an IEEE standard addressing mobility of
wireless broadband (WiMax). IEEE 802.16e is sometimes called Mobile WiMAX, after
the WiMAX forum for interoperability. 802.16e, based on an existing WiMAX standard
802.16a, adds WiMAX mobility in the 2-to-6 GHz-licensed bands. 802.16e allows for
fixed wireless and mobile Non Line of Sight (NLOS) applications primarily by enhancing
the OFDMA (Orthogonal Frequency Division Multiple Access).
IP
Internet Protocol. The standard that defines how data is transmitted over the Internet.
IP bundles data, including e-mail, faxes, voice calls and messages, and other types,
into "packets", in order to transmit it over public and private networks.
LAN
Local Area Network. A computer network limited to a small geographical area, such as
a single building. The network typically links PCs as well as shared resources such as
printers.
LED
Light Emitting Diode.
MAC Address
Standardized data link layer address that is required for every port or device that
connects to a LAN. Other devices in the network use these addresses to locate specific
ports in the network and to create and update routing tables and data structures. MAC
addresses are 6bytes long and are controlled by the IEEE.
BreezeMAX PRO 5000 CPE
95
Product Manual
Glossary
MCS
Multipoint Communications Systems. Applications licensed at 2500 MHz in Canada. A
wide variety of applications are possible including one-way and two-way transmission
and a diversity of distribution capacities.
MMDS
Multichannel Multipoint Distribution Service. MMDS is a licensed wireless service that
has the capability to provide broadband access. MMDS operates in several parts of the
2 GHz spectrum.
MSCHAP
Microsoft Challenge Handshake Authentication Protocol. an implementation of the
CHAP protocol that Microsoft created to authenticate remote Windows workstations. In
most respects, MS-CHAP is identical to CHAP, but there are a few differences.
MS-CHAP is based on the encryption and hashing algorithms used by Windows
networks, and the MS-CHAP response to a challenge is in a format optimized for
compatibility with Windows operating systems.
MSS
Maximum Segment Size.
NA
Not Available or Not Applicable
NE
Network Entry
NIC
Network Interface Card. An expansion board you insert into a computer (or a built-in
component) that enables the computer to connect to a network. Most NICs are
designed for a particular type of network, protocol, and media, although some can
serve multiple networks.
ODU
Outdoor Unit
OFDM
Orthogonal Frequency Division Multiplexing: A method for multiplexing signals, which
divides the available bandwidth into a series of frequencies known as tones.
Orthogonal tones do not interfere with each other when the peak of one tone
corresponds with the null. The rapid switching, frequency-hopping technique is
intended to allow more robust data service.
OFDMA
Orthogonal Frequency Division Multiple Access. It’s a logical extension of OFDM and a
modulation/multiple access technique. OFDMA divides a signal into sub-channels (i.e.
groups of carriers), with each sub-channel (or several sub-channels) being allocated to
a different subscriber.
PER
Packet Error Rate. In a digital transmission, PER is the percentage of packets with
errors divided by the total number of packets that have been transmitted, received or
processed over a given time period.
PHY
PHYsical Layer. The physical, or lowest, layer of the OSI Network Model. In a wireless
network, the PHY defines parameters such as data rates, modulation method, signaling
parameters, transmitter/receiver synchronization, etc. Within an actual radio
implementation, the PHY corresponds to the radio front end and baseband signal
processing sections.
BreezeMAX PRO 5000 CPE
96
Product Manual
Glossary
PPPoE
Point-to-Point Protocol over Ethernet. PPPoE relies on two widely accepted standards:
PPP and Ethernet. PPPoE is a specification for connecting the users on an Ethernet to
the Internet through a common broadband medium, such as a single DSL line, wireless
device or cable modem. All the users over the Ethernet share a common connection,
so the Ethernet principles supporting multiple users in a LAN combines with the
principles of PPP, which apply to serial connections.
QAM
Quadrature Amplitude Modulation. A technique used in wireless applications to double
the available bandwidth by combining two amplitude-modulated signals. The two
combined signals differ in phase by 90 degrees; this technique doubles the bandwidth
by combining the two signals at the source before transmission, transmitting digital data
at a rate of 4 bits per signal change.
QPSK
Quadrature Phase Shift Keying. A data transfer technique used in coaxial cable
networks that sends data using modulating signals. Four different phases represent
data, with each signal's information determined by the signal before it. For example, if a
phase stays the same from one signal to the other, the information has not changed.
RADIUS
Remote Authentication Dial-In User Service, an authentication and accounting system
used by many Internet Service Providers (ISPs). When you connect to the system you
must enter your username and password. This information is passed to a RADIUS
server, which checks that the information is correct, and then authorizes access to the
system.
RF
Radio frequency. An AC signal of high enough frequency to be used for wireless
communications.
RSSI
Received Signal Strength Indicator. A signal or circuit that indicates the strength of the
incoming (received) signal in a receiver.
R&TTE
Radio & Telecommunications Terminal Equipment. The R&TTE Directive 1999/5/EC
governs the marketing and use of R&TTE equipment. With the exception of a few
categories of equipment, the Directive covers all equipment, which uses the radio
frequency spectrum. It also covers all terminal equipment attached to public
telecommunication networks.
Rx
Receive
SAU
SU Alignment Unit
SDARS
Satellite Digital Audio Radio Service. A satellite-based direct-broadcast radio service in
which digitally encoded audio entertainment material is broadcast to earth-based
receivers from an orbiting satellite, either directly or via a repeater station.
SIP
Session Initiation Protocol. An application-layer control IETF protocol that can
establish, modify, and terminate multimedia sessions such as Internet telephony calls
(VoIP). SIP can also invite participants to already existing sessions, such as multicast
conferences. Media can be added to (and removed from) an existing session. SIP
transparently supports name mapping and redirection services, which supports
personal mobility - users can maintain a single externally visible identifier regardless of
their network location.
BreezeMAX PRO 5000 CPE
97
Product Manual
Glossary
SNMP
Simple Network Management Protocol. A network management protocol that provides
a means to monitor and control network devices, and to manage configurations,
statistics collection, performance, and security. SNMP works by sending messages,
called protocol data units (PDUs), to different parts of a network. SNMP-compliant
devices, called agents, store data about themselves in Management Information Bases
(MIBs) and return this data to the SNMP requesters.
SNR
Signal to Noise Ratio. The ratio of the amplitude of a desired analog or digital data
signal to the amplitude of noise in a transmission channel at a specific point in time.
SNR is typically expressed logarithmically in decibels (dB). SNR measures the quality
of a transmission channel or a signal over a network channel. The greater the ratio, the
easier it is to identify and subsequently isolate and eliminate the effects of noise. SNR
also is abbreviated as S/N.
SU
Subscriber Unit
TCP
Transmission Control Protocol. Connection-oriented transport layer protocol that
provides reliable full-duplex data transmission. TCP is the part of the TCP/IP suite of
protocols that is responsible for forming data connections between nodes that are
reliable, as opposed to IP, which is connectionless and unreliable.
TCP/IP
Transmission Control Protocol/Internet Protocol. A set of protocols developed by the
U.S. Department of Defense to allow communication between dissimilar networks and
systems over long distances. TCP/IP is the de facto standard for data transmission
over networks, including the Internet.
TDD
Time Division Duplex is a duplexing technique dividing a radio channel in time to allow
downlink operation during part of the frame period and uplink operation in the
remainder of the frame period.
TFTP
Trivial File Transfer Protocol. Simplified version of FTP that allows files to be
transferred from one computer to another over a network, usually without the use of
client authentication.
TR-069
TR-069 CPE WAN Management Protocol (CWMP) was created by the DSL Forum to
standardize management of CPEs over the Wide Area Network (WAN) . The TR-069
protocol specifically defines a common method for CPE devices to communicate with
an Auto Configuration Server (ACS).
Tx
Transmit
UDP
User Datagram Protocol. Connectionless transport layer protocol in the TCP/IP
protocol stack. UDP is a simple protocol that exchanges datagrams without
acknowledgments or guaranteed delivery, requiring that error processing and
retransmission be handled by other protocols. UDP is defined in RFC 768.
UL
Up Link
VLAN
Virtual Local Area Network. A group of devices on one or more LANs that are
configured with the same VLAN ID so that they can communicate as if they were
attached to the same wire, when in fact they are located on a number of different LAN
segments. Used also to create separation between different user groups.
BreezeMAX PRO 5000 CPE
98
Product Manual
Glossary
VoIP
Voice over Internet Protocol. Provides an advanced digital communications network
that bypasses the traditional public switched telephone system and uses the Internet to
transmit voice communication. VoIP enables people to use the Internet as the
transmission medium for telephone calls by sending voice data in packets using IP
rather than by traditional circuit switched transmissions of the PSTN.
WAN
Wide Area Network. A computer network that spans a relatively large geographical
area. Wide area networks can be made up of interconnected smaller networks spread
throughout a building, a state, or the entire globe.
WCS
Wireless Communications Services. The variety of services available using frequencies
in the 2.3 GHz band for general fixed wireless use.
WEEE
Waste Electronic and Electrical Equipment. The purpose of Directive 2002/96/EC on
waste electrical and electronic equipment (WEEE) is, as a first priority, the prevention of
waste electrical and electronic equipment (WEEE), and in addition, the reuse, recycling
and other forms of recovery of such wastes so as to reduce the disposal of waste. It
also seeks to improve the environmental performance of all operators involved in the
life cycle of electrical and electronic equipment, e.g. producers, distributors and
consumers and in particular those operators directly involved in the treatment of waste
electrical and electronic equipment.
WL (or W/L)
Wireless LAN
WIMAX
The name commonly given to the IEEE 802.16 standard. Specifications for fixed
broadband wireless metropolitan access networks (MANs) that use a
point-to-multipoint architecture. WIMAX supports very high bit rates in both uploading to
and downloading from a base station up to a distance of 30 miles.
BreezeMAX PRO 5000 CPE
99
Product Manual

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Author                          : Alvarion LTD.
Create Date                     : 2010:04:29 11:50:34Z
Modify Date                     : 2010:06:16 17:52:12+03:00
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : FrameMaker 8.0
Metadata Date                   : 2010:06:16 17:52:12+03:00
Format                          : application/pdf
Title                           : BreezeMAX PRO 5000 CPE.book
Creator                         : Alvarion LTD.
Producer                        : Acrobat Distiller 9.2.0 (Windows)
Document ID                     : uuid:297338b5-156e-4eac-8e12-bc376cf8e95c
Instance ID                     : uuid:f5757736-c159-478a-8caa-113654af7244
Page Mode                       : UseOutlines
Page Count                      : 116
EXIF Metadata provided by
EXIF.tools
FCC ID Filing: LKT-EXTR-CPE-49H