Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000TUser ManualSmartPoint TAmbient Systems B.V.Page 1 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000TProduct Code(s):900.100.025.003   (SP3000T),   900.100.025.005   (SP3000TH), 900.100.025.008   (SP3000TERS),   900.100.025.010   and     900.100.025.011 (SP3000T1W) Table of Contents1Preface.......................................................................................................31.1What is the SmartPoint SP3000T.................................................................................31.2Features...................................................................................................................... 31.3Conventions................................................................................................................ 31.4Further information..................................................................................................... 42Introduction................................................................................................52.1About This Manual....................................................................................................... 5Ambient Systems B.V.Page 2 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T2.2Related Documentation............................................................................................... 52.3Required Tools............................................................................................................. 53Product Types..............................................................................................64Installation..................................................................................................74.1Preparation.................................................................................................................. 74.2First Time Use.............................................................................................................. 74.3Mounting..................................................................................................................... 75Calibration..................................................................................................76Powering Options........................................................................................97LED Behavior.............................................................................................107.1Awaken from hibernation.......................................................................................... 107.2Rapid Response mode............................................................................................... 107.3Normal operation...................................................................................................... 108DDI Drivers................................................................................................119Storage.....................................................................................................1310Disposal..................................................................................................1311Appendices..............................................................................................1411.1Appendix A: Technical Support................................................................................14Ambient Systems B.V.Page 3 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T1 Preface1.1 What is the SmartPoint SP3000TThe   SmartPoint(SP)   SP3000T   combines   a   high   accuracy   temperature   sensor   and extensive logging capabilities with wireless communication capabilities. Due to the devices extreme energy efficiency, it has long battery life. The SP3000T is intended for   static   deployment   in,   for   example,   cool   cells   or   temperature   controlled warehouses, or mobile deployment, for example, attached to temperature sensitive produce. The temperature samples are conform EN12830 (type D). Optionally, the temperature   sensor   of   the   SP3000T   can   be   calibrated   (service   sold   separately, including calibration certificate). The   SP3000T   operates   inside   any   3000   Series   wireless   network   consisting   of   a ConnectGate(CG) or Gateway(GW) and MicroRouters(MRs). As soon as the SP3000T is activated and is in range  of an infrastructure device, it will start reporting the temperature1 at a 5 minute interval. Optionally, the SP3000T can be configured for different   reporting   rates   and   for   smart   alerting   based   on   temperature measurements.  Temperature  measurements   are  stored   for   up   to   28   days   in   the SP3000T.1.2 Features1. Accurate Temperature SensorThe internal TMP102 temperature sensor ???2. Low Power1 Assuming factory settings of the ESP3000T/H/CO2 and default security settings of the 3000 Series Infrastructure.Ambient Systems B.V.Page 4 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000TThe   internal   temperature   sensor   is   best-in-class   with   regards   to   energy consumption and enables long-term battery-operated usage.3. Long RangeThe   SP3000T   has   a   combined   Power   Amplifier   (PA)   &   Low  Noise   Amplifier (LNA) offering maximum radio range.4. Easy InstallationDue to the fact that the SP3000T is powered by an internal battery, it can be  configured and installed within minutes.5. Automated Logging & Flushing2The SP3000T has a 2MB internal Flash that is used to store up to 8K data samples. In case of temporary connection loss, the SP3000T will log its sensor readings and flush them fully automated once a connection is re-established, offering a high degree of redundancy and reliability.1.3 ConventionsThis   user   manual   uses   the   following   typographical   conventions   to   mark   certain portions   of   text:   new   terms,  foreign   phrases,   and   other   important   passages   are emphasized in italics.Everything that represents input or output of the computer, in particular commands, program code, and screen output, is shown in a mono-spaced font  and separated by borders. Within such passages, italics (example) indicate place-holders; you must insert an actual value instead of  the place-holder. On occasion, parts of program 2 Logging & Flushing is NOT enabled by default.Ambient Systems B.V.Page 5 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000Tcode are emphasized in bold face (example), if they have been added or changed since the preceding example.Important comments or reminders are indicated in bold and separated by borders, as follows:ExampleAn  administrator  is generally a person who is in charge of  installing and running Ambient Studio or any other related system software. A user could be anyone who is using, or wants to use, any part of the Ambient Studio system or the devices of the 3000   Series   Network.   An  engineer  is   generally   a   person   who   is   in   charge   of physically installing, deploying, or maintaining 3000 Series network devices.These terms should not be interpreted too narrowly; this user manual does not have fixed presumptions about system administration procedures.1.4 Further informationOther available resources providing related information include:•FAQThe   FAQ   list   contains   continuously   updated   answers   to   frequently   asked questions.•Web SiteThe Ambient Systems support website carries details on the latest release and other   information   to   make   your   experience   with   Ambient   Studio   more productive. The support website can be found at:Ambient Systems B.V.Page 6 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000Twww.ambient-systems.net The Support section can be accessed via login. Please contact our Customer Support via support@ambient-systems.netif you have not yet received the login details. Ambient Systems B.V.Page 7 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T2 Introduction2.1 About This ManualThis manual provides practical information for using the SP3000T. It addresses first-time use, installation and mounting instructions, operation, storage conditions, etc.2.2 Related DocumentationDocument DescriptionData Sheet:SP3000TThe SP3000T data sheet contains detailed information of the SP3000T specification.User Manual:Ambient StudioThe   Ambient   Studio   user   manual   contains   detailed information   regarding   Ambient   Studio,   our   software package   that   can   be   used   for   configuring   devices, support with installations, maintain   networks, set up remote connections, etc.Specification:DDI Class #11 TMP102The DDI Class #11 specification contains the API of the SP   driver   that   is   installed   on   the   SP3000T.   It   also contains   useful   information   regarding   device configuration, as well as the format of the temperature samples.Data Sheets, White Papers, DDI Specifications and Manuals can be downloaded from the support section of our website www.ambient-systems.net.Ambient Systems B.V.Page 8 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T2.3 Required ToolsIn order to verify proper operation of the SP3000T, the following devices and tools are required:1. GatewayA GW with power adapter and serial cable.2. Laptop/PCA laptop or Personal Computer(PC) is required to run Ambient Studio.3. Ambient StudioAmbient Studio needs to be installed on the laptop or PC.4. USB to Serial converterIn case the laptop or PC does not have a COM port, a USB to serial converter.Ambient Systems B.V.Page 9 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T3 Product TypesThere are four different types of the SP3000T, namely:•SP3000T•SP3000TH•SP3000TERS•SP3000T1WThe SP3000T only measures temperature. The other devices use this model as a basis and therefore also provide temperature samples, via the internal temperature sensor.The SP3000TH provides humidity samples.The SP3000TERS has an external reed switch which can be configured  to send a message when the reed switch is activated or deactivated.The   SP3000T1W   has   an   external   temperature   sensor   which   provides   additional temperature samples.The type of the SP3000T is indicated by the label on the exterior of the product.Ambient Systems B.V.Page 10 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T4 Installation4.1 PreparationBefore the SP3000T can be installed, please ensure you have all the required tools available. It is strongly recommended to first read the User Manuals on the Ambient 3000 Series 3rd Generation Active RFID and Ambient Studio. Knowledge of Ambient Studio is a pre-requisite in order to verify the operational status of the SP3000T and associated configuration.4.2 First Time Use1. Prepare 3000 Series network and Ambient Studio3Ensure that Ambient Studio  is running  and a GW is powered, and  properly connected to the PC. The GW needs to display an ‘online’ status in Ambient Studio. The green LED of the GW needs to be lit. MRs and other SPs can be added to the network as long as care is taken with regards to the network congestion. Navigate to the ‘Drivers’ tab in Ambient Studio and, if necessary, unfold the SP branch in the tree control on the left hand side of the screen.2. Awaken the SP from hibernationGenerally,   the   devices   are   delivered   in   hibernation   to   avoid   unnecessary power drain. Use a Magnetic Mat(MM) to awaken the device, by following the instructions on the MM. Once awake, the SP will send a DDI (4:8:2) message to indicate that it has exited the hibernation state.3  Ensure your Ambient Studio version is the latest version available and that you have all required DDI XML filesAmbient Systems B.V.Page 11 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T3. Observe readings from SP in Ambient StudioOnce   awakened,   the   device   will   adopt   operational   status.   The   SP   is   now visible   in   Ambient   Studio.   In   default   configuration,   the   SP   will   report temperature every 15 minutes in  a message from the DDI driver DDI(11:1:1) TMP::TMP102. In the ‘DDI’ tab of Ambient Studio, set the filter to select the ID of   the   device.   The   received   queue   should   display   all   received   DDI(11:1:1) messages.If the aforementioned messages are being received, the device has started correctly and is operational.If the  SP does   not   report  periodically, or sends  out   messages  of   DDI type  FLUSHPUSH,   it   is   possible   that   the   device   does   not   have   a   sufficient connection   with   the   infrastructure.   Use   the   Ambient   Studio   ‘Map’   view   to visualize   the   infrastructure   and   SP   links.   When   the   DDI   (3:9) Network::SmartPoint   driver   has   been   enabled,   it   will   periodically   PUSH network   link   quality   information   updates.   If   the   reported   RSSI   values   are approaching to  the lower limit  ???,   either a   MR needs  to   be added  to the network, or the device needs to be moved closer to a MR or GW.Ambient Systems B.V.Page 12 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T4.3 MountingThe SP3000T has a single mounting hole in the centre of the casing. This can be used in various ways to attach the device to the required surface, e.g.   bolt and magnet, cord, or tie wrap.5 CalibrationAmbient   offers   a   calibration   service   which   allows   the   calibration   of   the   internal sensor(s).   This   calibration   is   performed   by   an   independent   certified   calibration institute. Contact our support department for more information.It is also possible to manually “calibrate” the sensor via the corresponding driver, e.g. DDI (11:1:1) Temperature:TP102.Ambient Systems B.V.Page 13 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T6 Powering OptionsThe SP3000T has an internal battery pack which, even in hibernation will be subject to   a   minute   and   continuous   drain   and   should   typically   be   replaced   once   every   5 years4. Ambient   offers   a   refurbishment   service   for   devices   which   require   a   battery replacement. Contact our support department for more information.4 Under the assumption that power loss occurs once every month for a period of 24 hours.Ambient Systems B.V.Page 14 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T7 LED Behavior7.1 Awaken from hibernationWhen the SP awakens from hibernation, the device will flash the internal LED several times.7.2 Rapid Response modeAfter awakening from hibernation, the device enters a rapid response mode for a period of 15 minutes. During this period, the device will flash the internal LED every 30 seconds.7.3 Normal operationDuring normal operation (default configuration), the SP does not flash the internal LED.It is possible to configure the SP to flash the internal LED upon status change of the internal reed switch. See DDI (17:2) Contact:Reed for more details.Ambient Systems B.V.Page 15 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T8 DDI DriversThe following DDI drivers are installed on the SP3000T•DDI(0:0) System::DDI•DDI(0:1) System::Echo•DDI(0:2) System::Version•DDI(0:3) System::FileSystem•DDI(0:4) System::Reset•DDI(0:10) System::SmartPointPower•DDI(0:12) System::Logger•DDI(0:13) System::KeyManager•DDI(0:15) System::SmartPointLED•DDI(3:5) Network::RapidClient•DDI(3:9) Network::SmartPoint•DDI(3:10) Network::SmartPointExtendedSleep•DDI(4:8) Utility::Hibernate•DDI(11:1) Temperature::TMP102Ambient Systems B.V.Page 16 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000TThe SP3000TH has the following additional driver:•DDI(12:1) Humidity::SHT-HThe SP3000ERS has the following additional driver:•DDI(17:1) Contact::OpenCloseThe SP3000T1W has the following additional driver:•DDI(11:5) Temperature::DS18B20Ambient Systems B.V.Page 17 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T9 StorageThe SP3000T should be stored in a dry area at room temperature.10 DisposalAll   SP3000T   products   are   considered   Waste   Electrical   and   Electronic   Equipment (WEEE) and should be disposed of accordingly. If you have any questions regarding this matter, please contact our support department.Ambient Systems B.V.Page 18 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.
Model: SP3000T Revision P1A/01102013USER MANUALSmartPoint SP3000T11 Appendices11.1 Appendix A: Technical SupportYou   can   contact   Ambient   Systems   technical   support   through   our   web   site   or   by email. Before you contact technical support, please have the following ready:1. Ambient Studio version (see About box)2. Device serial ID, model numberIf   you   have   encountered   any   problems,   please   visit   the   support   section   of   our website, where you can find software updates and user documentation, as well as Frequently Asked Questions (FAQ) and answers to technical issues.Website: www.ambient-systems.net Then browse to the support sectionE-mail: support@ambient-systems.net   Ambient Systems B.V.Page 19 of 19Colosseum 15D • 7521 PV Enschede • The NetherlandsT: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.netKvK: 08122911 • VAT NL: 81297625381CHECK.TRACK.TRACE.