Amtran Technology Co UW-011 U-Wake Brainwave Detection Device User Manual

Amtran Technology Co Ltd U-Wake Brainwave Detection Device

User Guide Rev.02 (150529)

Download: Amtran Technology Co UW-011 U-Wake Brainwave Detection Device User Manual
Mirror Download [FCC.gov]Amtran Technology Co UW-011 U-Wake Brainwave Detection Device User Manual
Document ID2630169
Application ID11Ti8DtERwCB7OI0RdGklg==
Document DescriptionUser Guide Rev.02 (150529)
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.69kB (358586 bits)
Date Submitted2015-05-30 00:00:00
Date Available2015-06-02 00:00:00
Creation Date2015-05-29 11:26:42
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2015-05-29 11:26:42
Document Titleuntitled

1. Introdu
uction
Your U-Wake is designed to help yo
ou keep awake from driving fatiigue. Via the U--Wake applicatio
on on your
Andro
oid™/IOS devicce, you can syncchronise data with
w your U-Wake
e headband to see
s the brainwa
ave status in real time.
The Apps
can also make
noise / vib
bration in order to
t alert you , be
esides , the call-help message w
will also send to
o your
friend
d that you selecct via social-med
dia . To wear U--Wake device and use U-Wake
e application , it will try best to keep
you falling
asleep wh
hen you were driving.
2. Hardw
ware ov
verview
1 Se
ensor plate
2 He
eadband
3 Ea
ar Clip
4 Po
ower button
5 No
otification light A
6 Notification light B
7 Notification light C
8 Micro USB port
9 Reset hole
10 Insulation hole
11 Clip
12 Strap hole
3. Charging your U-Weak
Before using your U-Weak for the first time, you need to charge it for approximately 12 Hours. Chargers are
recommended. (Low battery Red is flashed / Charging red is continuously light / Charging full red light is off)
To charge your U-Weak
1.
Plug one end of the USB cable into the USB charger.
2.
Plug the other end of the cable into the Micro USB port of your U-Weak
Battery notification light status
Notification light red continuously : The battery is charging and is not yet fully charged
Notification light red is off :
The battery is fully charged
Low battery level notification
When your U-Weak is on and the battery level is less than 10%, your U-Weak Red light is flashed.
To check the battery level of your U-Weak
1.
From the Home screen of your Android™ device
Note : The battery of this device cannot not be changed
4. Assembly
1
1.
To hold the
e U-Wake in ho
orizontal posittion, slide the device backw
wards so that th
he sensor can
contact you
ur forehead so
o closely
2.
Clip the earr sensor onto your ear lobe..
4.
FIX YOUR CONTROL BOX
1.
To fix the control box in any place of cloth that you prefer .
2.
To Push the power key over 1 second to turn the power on .
5.Turning your U-Weak on and off
To turn on your U-Weak
Press and hold down the power key until your When your U-Weak is on (Green light continuously on, Blue light is
flashes).
To turn off your U-Weak
Press and hold down the power key until all LED light is off
6. Preparing to use your U-Wake
For your U-Wake to work it must be connected to your Android™ / IOS™ device and the latest versions of the
following applications must be installed on the Android™ / IOS™ device.
To set up your U-Wake using Bluetooth®
1.
Make sure that your U-Wake has been charged for at least 3 hours.
2.
Android™/ IOS™device: Make sure you have installed or updated the U-Wake application to the
latest version from Google Play™ / Apple Store™.
3.
Turn on your U-Wake (Press the power key over 3~5 second). After U-Wake is power on. (Green
light continuously on, Blue light is flashes, Blue light is Bluetooth status indication).
4.
Wearing your U-Wake. Headband on the forehead head and main box can be clipped anywhere
that you preferred.
5.
Please make sure headband sensor and ear clip is contacted closely to your forehead / ear.
6.
Android™ /IOS device: Turn on the Bluetooth® function.
7.
Run the U-Wake application , then scan for Bluetooth® devices and select U-Wake in the list
8.
When Bluetooth is connection Blue light is continued on
PS:
When Bluetooth connection 3 minute Green light will be turn off / Blue light is always on.
7.Resetting your U-Wake
Reset your U-Wake if it behaves unexpectedly.
To reset your U-Wake
1.
If it behaves unexpectedly U-weak can’t turn on, please press the needle button 1~2 sec for reset
8.Trouble shooting
1.
If press and hold down the power key but can’t turn onÎ (1) Please charge again (2)Use needle
to press the reset key in order to do the hardware reset .
2.
If LED light work abnormal Î Please use needle to press the reset key then turn on again.
3.
If brainwave signal is poor,Î a. Please clean up your headband sensor & ear clip sensor
b. Please make sure headband sensor and ear clip is contacted
closely to your forehead / ear.
c. Please don’t use the U-Wake when U-Wake device is in charge
9.Using the U‐Wake application
You can view and change settings for your U-Wake from the U-Wake application .
Menu
Zone selection ( 50/60 Hz)
Battery status indication
Drowsiness Score ( 0 ~ 100 )
Detection Status
Real time brainwave form
Brainwave form history
10.Product spec
Model Name
Features
Brainwave
Brainwave Patterns
Specification
Wearing Style
Transmission type
BT Spec
Headset
Battery Spec
Battery average operating time
Contact pressure
Button
I/O interface
Charging interface
U‐Wake UW‐011
• Direct connect to dry electrode
• One EEG channel + Reference + Ground
• Extremely low‐level signal detection
• Advanced filter with high noise immunity
• Fatigue
• Low Attention
• 256Hz sampling rate
• 3‐25Hz frequency range
• Max Power Consumption: 45mA @ 3.3V • Operating voltage 3.0V ~4.2V (TBD)
• Headband
• BLE ( Support above android 4.3 & IOS)
• IC compatible for BLE
• Output:Bluetooth power 0.5mW
• Transmission Distance:~ 30 feet
• Frequency Range :2.4GHz (2.4000GHz‐2.4835GHz)
• Interface:GATT profile
• 4.2V/600mA
~ 20 hours
~ 7 N (± 0,3 N)
Power Key
•Micro USB ; Brainwave Sensor ; Ear Clip
• By Micro USB
Dimension : 164.3mm(L)*165mm(W)*25mm(H)
Carton Size : 12pcs / Ctn , 1147(D)*162(W)*210(H)mm
Net Weight : 210 g
Container Load : 4,200 pcs / 20"
11.Safety Label Information
FEDERAL COMMUNICATIONS COMMISSION
INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
‐‐ Reorient or relocate the receiving antenna.
‐‐ Increase the separation between the equipment and receiver.
‐‐ Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
‐‐ Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
To assure continued FCC compliance:
Any changes or modifications not expressly approved by the grantee of this
device could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be co‐located or operating in
conjunction with any other antenna or transmitter.
IC
This device complies with Industry Canada license‐exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be co‐located or
operating in conjunction with any other antenna or transmitter.
Cet appareil radio est conforme au CNR‐210 d’Industrie Canada. L’utilisation
de ce dispositif est autorisée seulement aux deux conditions suivantes : (1) il
ne doit pas produire de brouillage, et (2) l’utilisateur du dispositif doit être
prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est
susceptible de compromettre le fonctionnement du dispositif.
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies
pour un environnement non contrôlé. Cet émetteur ne doit pas être co‐localisées ou
opérant en conjonction avec tout autre antenne ou transmetteur.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Modify Date                     : 2015:05:29 11:26:42+08:00
Create Date                     : 2015:05:29 11:26:42+08:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:10905029-6cf5-4018-a009-ece0d18fddde
Instance ID                     : uuid:bfa3ee71-c0f2-4b7e-bfa1-2ff68065fdc8
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MDZUW-011

Navigation menu