WELL-X-TROL PROFESSIONAL
Pre-Pressurized
Water System
Tanks
WELL-X-TROL®Professional
revolutionizes
the industry
WELL-X-TROL®Professional redefined the industry with its advanced engineering and
innovative product design including the pre-pressurized well tank, sealed-in air charge,
and unique water chamber design. With proven performance since 1963, WELL-X-TROL
Professional continues to deliver unparalleled results making it the most trusted choice
of professionals in today’s market.WELL-X-TROL Professional offers many unique features
that result in consistent, reliable performance, including design elements that prevent tank
corrosion and reduce wear and tear on the well pump.
Features and Benefits
Exclusive butyl diaphragm, along with the 100% corrosion resistant virgin polypropylene
liner, are secured by a positive hoop ring seal for added strength and reliability. This
totally integrated system outperforms other types of water chamber designs.
The stainless steel air valve is welded rather than threaded to prevent loss of air pressure.
The finest quality, custom mill steel is used in the deep drawn dome
for extra strength while keeping tank weight to a minimum.
More choices mean more flexibility
WELL-X-TROL Professional offers more options and sizes
than any other well tank manufacturer, including both
vertical and horizontal designs, and sizes ranging
from 2 gallons to 119 gallons so you can
configure a system that’s right for any
application.
First on Industry Safety
Standards
WELL-X-TROL Professional tanks were the
first to meet all industry standards for quality
and safety. The butyl diaphragm in all models
meets EPA requirements for potable water as
defined in the Safe Drinking Water Act of
1986. The entire tank which includes the
virgin polypropylene liner, butyl diaphragm,
and acceptance fittings for a 100% corrosion
resistant water reservoir is listed by NSF
International Standard 61.
Advanced design features
continue to set industry standards
Stainless steel air valve is welded in position rather than mechanically
threaded to prevent loss of air pressure and to minimize stress on the well’s
pump system. It also carries a tamper-evident warning label.
Deep-drawn steel domes offer twice the strength of rolled steel while
minimizing weight.
Unique positive hoop ring seal secures diaphragm and liner for added
strength and reliability.
Heavy duty butyl diaphragm features seamless construction for uniform
strength and flexibility. It conforms exactly to the shell configuration without
stretching, creasing, or forming bubbles or corners that could trap water or
sediment. Butyl is the best known elastomer to prevent air loss.
Heavy duty butyl diaphragm is extremely resistant to bacterial growth and
meets FDA requirements for potable water supply.
Virgin polypropylene liner provides a 100% corrosion resistant, non-metallic
rigid water reservoir that is listed by NSF International Standard 61.
Stainless-steel system connection withstands aggressive water.
Exclusive welding process eliminates interior rough spots and sharp edges
which prevent damage to the diaphragm and liner.
Each finished tank is pressure tested for safety.
Each finished tank is pre-pressurized to the most common pump cut-in
pressure.
Exterior appliance-like finish looks attractive while protecting the tank from
the elements.
Dome
Hoop
Diaphragm
Liner
Dome
Stainless-steel
System
Connection
Stand
esp(Effective System Protection):
maximum system output with
minimal pump starts
The ESP sizing procedure covers modern residential water-use habits, increased off-peak
demands and the general increase in water use that have occurred over the past twenty-five years.
ESP sizing is designed to reduce pump wear and tear, and reduce energy consumption by keeping
pump starts to a minimum.
Choose the amount of protection you need.
ESP I: Tank selection is based on approximately one minute minimum pump running time.
This is recommended for pumps up to 3/4 H.P.
ESP II: Tank selection is based on approximately two minute minimum pump running time.
This is recommended for 3/4 H.P. or larger pumps.
ESP Sizing Table
OPERATING PRESSURE - PSIG
PUMP DISCHARGE ESP I ESP II
RATE GPM (Approx.) 20/40 30/50 40/60 20/40 30/50 40/60
5 WX-202 WX-202 WX-202 WX-202XL WX-205 WX-205
7 WX-202 WX-202 WX-202XL WX-205 WX-250 WX-251
10 WX-202XL WX-205 WX-205 WX-251 WX-251 WX-255
12 WX-205 WX-250 WX-250 WX-251 WX-255 WX-255
15 WX-250 WX-250 WX-251 WX-255 WX-302 WX-350
20 WX-251 WX-251 WX-255 WX-350 WX-350 (2) WX-255
25 WX-251 WX-255 WX-302 (2) WX-251 (2) WX-255 (2) WX-302
30 WX-255 WX-302 WX-350 (2) WX-255 (2) WX-302 (2) WX-350
35 WX-302 WX-350 WX-350 (2) WX-302 (2) WX-350 (2) WX-350
40 WX-350 WX-350 (2) WX-255 (2) WX-350 (2) WX-350 (3) WX-302
1
2
3
4
WELL-X-TROL Professional has a sealed in air chamber that is pre-pressurized
before it leaves our factory. Air and water do not mix.
When the pump starts, water enters the
WELL-X-TROL Professional. Only usable
water is stored.
When the pressure in the chamber
reaches cut-out pressure, the pump
stops. The WELL-X-TROL Professional
is filled.
When water is demanded, pressure
in the air chamber forces water into
the system. Since WELL-X-TROL
Professional consistently delivers the
maximum usable water, minimum
pump starts are assured.
WELL-X-TROL Professional
tank operation
time-tested design
In-Line Models
Stand Models
WELL-X-TROL Professional
residential
models
Underground Models
Dimensions Total Max. System Drawdown Shipping
Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-101 8 12 5/8 2.0 0.45 .8 .7 .6 5 (0.6)
WX-102 11 15 4.4 0.55 1.8 1.5 1.3 9 (1.2)
WX-103 11 22 1/4 7.6 0.42 3.1 2.6 2.2 15 (1.8)
WX-104 15 3/8 17 3/4 10.3 1.00 4.1 3.5 3.0 20 (2.6)
WX-200 15 3/8 22 14.0 0.81 5.6 4.8 4.1 22 (3.3)
Precharge Pressure for WX-101
& WX-102 is 20 PSIG and Sys. Conn. is 3/4" NPTM.
Precharge Pressure for WX-103 is 30 PSIG and Sys. Conn. is 3/4" NPTM.
Precharge Pressure for WX-104 and WX-200 is 30 PSIG and Sys. Conn. is 1" NPTM.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
WX-101 and WX-102 models available with Ultra TUF-KOTETM exterior coating option.
Dimensions Total Max. System Drawdown Shipping
Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-104-S 15 3/8 19 1/4 10.3 1.00 4.1 3.5 3.0 23
WX-201 15 3/8 23 7/8 14.0 0.81 5.6 4.8 4.1 25
WX-202 15 3/8 31 5/8 20.0 0.57 8.0 6.8 5.9 33
WX-202XL 15 3/8 38 1/4 26.0 0.44 10.5 8.8 7.6 36
WX-203 15 3/8 46 1/2 32.0 0.35 —- 10.9 9.4 43
WX-205 22 29 5/8 34.0 1.00 13.7 11.6 10.0 61
WX-250 22 36 44.0 0.77 17.7 15.0 12.9 69
WX-251 22 46 3/4 62.0 0.55 24.9 21.1 18.2 92
WX-255 22 56 3/8 81.0 0.41 32.6 27.5 23.8 103
WX-252 22 62 1/4 86.0 0.39 34.6 29.2 25.3 114
WX-302 26 47 1/4 86.0 0.54 34.6 29.2 25.3 123
WX-350 26 61 7/8 119.0 0.39 47.8 40.5 35 166
Precharge Pressure for WX-104-S thru WX-203 is 30 PSIG and Sys. Conn. is 1" NPTF.
Precharge Pressure for WX-205 thru WX-350 is 38 PSIG and Sys. Conn. is 1 1/4" NPTF.
Maximum Working Temperature is 200° F. Maximum Working Pressure for all models except WX-252 is 125 PSIG.
Maximum Working Pressure for WX-252 is100 PSIG.
All models available with
Ultra TUF-KOTETM
except WX-104-S, WX-201, and WX-252.
All models except, WX-104S, WX-201, WX-252 are available with Pro-Access.
Dimensions Total Max. System Drawdown Shipping
Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-200-UG 15 3/8 22 14.0 0.81 5.6 4.8 4.1 22
WX-202-UG 15 3/8 30 20.0 0.57 8.0 6.8 5.9 30 (4.9)
WX-250-UG 22 33 3/8 44.0 0.77 17.7 15.0 13.0 60 (9.8)
WX-251-UG 22 44 1/8 62.0 0.55 24.9 21.1 15.3 83 (13.9)
Precharge Pressure for WX-202-UG is 30 PSIG and Sys. Conn. is 1" NPTF Coupling.
Precharge Pressure for WX-205-UG and WX-251-UG is 38 PSIG and Sys. Conn. is 1 1/4" NPTF Coupling.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
WELL-X-TROL Professional
specialty residential
models
Pump Stand Models
Offset Connector Models
Space Saver Model
Specialty Options
Dimensions Total Max. System Drawdown Shipping
Model Height Width Length Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-105-PS 11 10 9/16 18 1/4 5.3 0.80 2.1 1.8 1.6 13
WX-200-PS 16 15 3/8 20 7/8 14.0 0.81 5.6 4.8 4.1 29
Precharge Pressure is 30 PSIG and Sys. Conn. is 3/4" NPTM Fitting for 103-PS and 105-PS; and 1" NPTF Coupling for 200-PS.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
Dimensions Total Max. System Drawdown Shipping
Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-202-OC 15 3/8 29 20.0 .57 8.0 6.8 5.9 32 (5.0)
1” Barb Connection. 30 PSIG Precharge Pressure. 100 PSI Maximum Working Pressure. 200° (F) Maximum Working Temperature
Dimensions Total Max. System Drawdown Shipping
Model Height Width Length Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-202-H 28 5/8 15 3/8 15 1/4 20.0 0.57 8.0 6.8 5.9 33 (4.9)
Precharge Pressure is 30 PSIG. System connection is 1" NPTF (straight coupling connection).
Maximum Working Pressure is 125 PSIG. Maximum Working Temperature is 200° F.
A new improved paint finish available only on WELL-X-TROL tanks.
This new paint has been re-formulated for outdoor applications where acids, salts
and moisture can harm regular paint. It is crack proof and impermeable to moisture.
PRO Access Stainless Steel System Connection piped through the stand is available
on most WELL-X-TROL models. Indicate PRO Access when ordering.
Hydrogen Sulfide Removal System Arsenic Removal System
Iron Removal System Water Softening and Filtration
Part# 9015-516 MC# 4380 (7/04) © 2004 AMTROL Inc. WELL-X-TROL is a registered trademark of AMTROL Inc.
Ask for Quality. Ask for AMTROL®.
®
AMTROL has
innovative ways
to help you grow your business
Boiler Expansion Tanks Water Heater Expansion Tanks Indirect-Fired Water Heaters
®
®
Corporate Headquarters
1400 Division Road
West Warwick, RI 02893
Telephone: 401-884-6300
Fax: 401-884-5276
AMTROL Canada, Ltd.
275 Shoemaker Street
Kitchener, Ontario N2E 3B3
Telephone: 519-748-1138
Fax: 519-748-4231
www.amtrol.com
Water Treatment Technologies
Hydronic Technologies

Navigation menu