Amx Ni 2100 Users Manual 0602998 NI2100 3100 4100 Hardware
NI-2100 to the manual 85d1c04b-d425-4768-be93-4853a39d4c63
2015-02-05
: Amx Amx-Ni-2100-Users-Manual-509005 amx-ni-2100-users-manual-509005 amx pdf
Open the PDF directly: View PDF .
Page Count: 36
Download | |
Open PDF In Browser | View PDF |
Hardware Reference Guide NI-x100 Series NetLinx® Integrated Controllers (NI-2100, NI-3100, NI-4100) NetLinx Integrated Controllers L a s t R e v i s e d : 1 /9 / 2 0 0 9 AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. • Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. • AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX does guarantee the control of dimmable loads that are properly connected to our lighting products. The dimming performance or quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers. • Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. • AMX Software is warranted for a period of ninety (90) days. • Batteries and incandescent lamps are not covered under the warranty. This warranty extends only to products purchased directly from AMX or an Authorized AMX Dealer. All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a valid RMA number. AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX or an authorized representative of AMX has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY. Table of Contents Table of Contents Introduction ........................................................................................................1 NI-2100 Specifications .............................................................................................. 2 NI-3100 Specifications .............................................................................................. 5 NI-4100 Specifications .............................................................................................. 8 Related Documents................................................................................................. 11 Installation and Upgrading ...............................................................................13 Installing NetLinx Control Cards (NI-4100 Only) ..................................................... 13 Setting the NetLinx Control Card Addresses (NI-4100 Only).................................. 14 Device:Port:System (D:P:S)............................................................................................ 14 Removing NetLinx Control Cards (NI-4100 Only) ................................................... 15 Compact Flash Upgrades ........................................................................................ 15 Accessing The Internal Components On An Integrated Controller ............................... 15 Installation of Compact Flash Upgrades........................................................................ 16 Closing and Securing the Outer Housing ...................................................................... 17 Installing Into An Equipment Rack .......................................................................... 17 Connections and Wiring ...................................................................................19 Setting the Configuration DIP Switch (for the Program Port) ................................. 19 Baud Rate Settings........................................................................................................ 19 Program Run Disable (PRD) Mode................................................................................. 19 Working With the Configuration DIP Switch ................................................................. 20 Setting the CardFrame DIP Switch (NI-4100 Only) ................................................. 20 Program Port Connections and Wiring ................................................................... 20 Modes and Front Panel LED Blink Patterns ............................................................ 21 Port Assignments and Functionality........................................................................ 21 AXlink Port and LED ............................................................................................... 22 Wiring Guidelines ................................................................................................... 22 Wiring length guidelines ............................................................................................... 22 Preparing Captive Wires ............................................................................................... 23 Wiring a Power Connection........................................................................................... 23 Using the 4-Pin Mini-Phoenix Connector For Data and Power ...................................... 23 Using the 4-pin Mini-Phoenix Connector For Data With External Power ...................... 24 DB9 Device Port: Connections and Wiring ............................................................. 24 ICSNet Port: Connections and Wiring..................................................................... 25 ICSHub OUT Port: Connections and Wiring ............................................................ 26 Relay Port: Connections and Wiring ....................................................................... 26 Relay Connections ......................................................................................................... 26 NI-2100, NI-3100, NI-4100 Hardware Reference Guide i Table of Contents Input/Output (I/O) Port: Connections and Wiring ................................................... 27 IR/Serial Port: Connections and Wiring................................................................... 28 NetLinx Control Card Slot Connector (NI-4100 only).............................................. 28 Ethernet/RJ-45 Port: Connections and Wiring ........................................................ 29 Ethernet LEDs .............................................................................................................. 29 Ethernet Ports Used By the Integrated Controller ........................................................ 30 ii NI-2100, NI-3100, NI-4100 Hardware Reference Guide Introduction Introduction The X100-Series of NetLinx Integrated Master Controllers can both be programmed to control RS-232/422/485, Relay, IR/Serial, and Input/Output devices through the use of both the NetLinx programming language and the NetLinx Studio application version 2.x. Another key feature of this products is the ability to easily access the configuration switches without having to remove a cover plate. NetLinx Integrated Master Controller Features NI-2100 (FG2105-04) • 1 RS-232 Program port • 3 RS-232/RS-422/RS-485 ports • 4 IR/Serial Output ports • 4 Digital Input/Output ports • 4 Relays NI-2100 Kit (FG2105-14) • In addition to the options listed above, this Kit includes a pre-installed ICSNet daughter card (FG2105-10) NI-3100 (FG2105-05) • 1 RS-232 Program port • 7 RS-232/RS-422/RS-485 ports • 8 IR/Serial Output ports • 8 Digital Input/Output ports • 8 Relays NI-3100 Kit (FG2105-15) • In addition to the options listed above, this Kit includes a pre-installed ICSNet daughter card (FG2105-10) NI-4100 (FG2105-06) • Support for up to 4 NetLinx control cards (such as NXC-COM2, NXC-IRS4, etc.) • 1 ICSNet Hub port (part of the included pre-installed ICSNet card) • 1 RS-232 Program port • 2 ICSNet ports (part of the included pre-installed ICSNet card) • 7 RS-232/RS-422/RS-485 ports • 8 IR/Serial Output ports • 8 Digital Input/Output ports • 8 Relays References within this manual to NI X100-Series Controllers are used to describe the NI-2100/3100/4100 Integrated Controllers. When there is an overlap of information with other related NI Controllers, an X will be used to refer to both sets of units. As an example, if a feature is shared by both the NI-4000 and the NI-4100 Controller, the term NI-4x00 Series is used. These NI Controllers are shipped with Duet firmware and can not be downgraded to earlier Non-Duet firmware (< build 300). These NI Controllers are Duet-compatible and can be upgraded via firmware. Duet is a dual-interpreter firmware platform from AMX which combines the proven reliability and power of NetLinx with the extensive capabilities of the Java®2 MicroEdition (J2ME) platform. Duet simplifies the programming of a system that includes the NI-900 and other third party devices by standardizing device and function definitions, defaulting touch panel button assignments, and controlling feedback methods. Dynamic Device Discovery makes integration even easier by automatically identifying and communicating with devices which support this new beaconing technology. NI-2100, NI-3100, NI-4100 Hardware Reference Guide 1 Introduction These NI Controllers use a combination lithium battery and clock crystal package called a Timekeeper. Only one Timekeeper unit is installed within a given NI controller. The battery can be expected to have up to 3 years of usable life under very adverse conditions. Actual life is appreciably longer under normal operating conditions. This calculation is based on storing the unit without power in 50° C (120° F) temperature until battery levels are no longer acceptable. The part number for a replacement battery is 57-0032. NI-2100 Specifications The NI-2100 (FIG. 1) provides support for 3 RS-232/RS-422/RS-485 Ports, 4 IR/Serial Output ports, 4 Digital Input/Output ports, and 4 Relays. The NI-2100 can be upgraded to provide 1 ICSHub and 2 ICSNet ports by either installing the optional ICSNet daughter card (FG2105-10) or purchasing this upgrade as an included feature of the NI-2100 Kit (FG2105-14). FIG. 1 NI-2100 NetLinx Integrated Controller (front view) RS-232/422/485 TX/RX LEDs (red/yellow) Link/Active-Status-Output-Input Relay LEDs (red) IR/Serial LEDs (red) LINK/ACT STATUS INPUT OUTPUT 1 2 3 1 TX RX TX RX TX RX RS - 232 / 422 / 485 2 3 4 1 RELAYS 2 3 4 1 IR / SERIAL 2 3 4 I/O I/O LEDs (yellow) Front AXlink LED (green) ICSNet cover plate Relays (Port 4) RS-232/422/485 (Ports 1-3) PORT 3 PORT 2 PORT 1 Ethernet IR/Serial (Ports 5-8) Pin 1 2 3 4 5 Rear I/O (Port 9) RS - 232 / 422 / 485 (Ports 1-3) Function Pin Function RXRXD TXD TX+ GND 6 7 8 9 RX+ RTS CTS TX- DIP switch Program port AXlink port ETHERNET 10 / 100 L/A SPD PWR ID Pushbutton FIG. 2 NI-2100 front and rear panel connectors and components 2 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Introduction NI-2100 Specifications Dimensions (HWD): • 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm) • 2 rack units high Power Requirement: 700 mA @ 12 VDC Memory: • 64 MB SDRAM Compact Flash: 128 MB or more - Upgradeable (see Other AMX Equipment) • 1 MB Non-volatile (NV) SRAM Note: AMX may increase Flash size at any time in response to market availability (refer to product’s online catalog page for current Compact Flash size provided). Weight: 4.50 lbs (2.04 kg) Enclosure: Metal with black matte finish Certifications: FCC Part 15 Class B, CE, and IEC 60950 Front Panel LEDs: • LINK/ACT: Green LED blinks when the Ethernet cables are connected and terminated correctly. Also blinks when receiving Ethernet data packets. • Status: Green LED blinks to indicate that the system is programmed and communicating properly. • Output: Red LED blinks when the Controller transmits data, sets channels On and Off, sends data strings, etc. • Input: Yellow LED blinks when the Controller receives data from button pushes, strings, commands, channel levels, etc. • RS-232/422/485: 3 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 3 are transmitting or receiving RS-232, 422, or 485 data. • Relay: 4 red LEDs light to indicate the relay channels 1 - 4 are active (closed). These LEDs reflect the state of the relay on Port 4. • IR/Serial: 4 red LEDs light to indicate the IR/Serial channels 1 - 4 are transmitting control data on Ports 5 - 8. LED indictor for each IR port remains lit for the length of time that IR/Serial data is being generated. • I/O: 4 yellow LEDs light when the I/O channels 1 - 4 are active. The LED for each I/O port reflects the state of that particular port. Rear Panel Components: • RS-232/422/485 (Ports 1 - 3): 3 RS-232/422/485 control ports using DB9 (male) connectors with XON/ XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-115,200 baud. • ICSNet: 2 RJ-45 connectors for ICSNet interface (provided by optional ICSNet daughter card). • ICSHub Out: RJ-45 connector provides data to a Hub connected to the Controller (provided by optional ICSNet daughter card). • Relay (Port 4): • Four-channel single-pole single-throw relay ports • Each relay is independently controlled. • Supports up to 4 independent external relay devices • Channel range = 1-4 • Each relay can switch up to 24 VDC or 28 VAC @ 1 A 8-pin 3.5 mm mini-Phoenix (female) connector provides relay termination • Digital I/O (Port 9): 4-channel binary I/O port for contact closure with each input being capable of voltage sensing. Input format is software selectable with interactive power sensing for IR ports. NI-2100, NI-3100, NI-4100 Hardware Reference Guide 3 Introduction NI-2100 Specifications (Cont.) Rear Panel Components (Cont.): • IR/Serial (Ports 5 - 8): 4 IR/Serial control ports support high-frequency carriers of up to 1.142 MHz with each output being capable of two electrical formats: IR or Serial. • 4 IR/Serial data signals can be generated simultaneously. • IR ports support data mode (at limited baud rates and wiring distances). • Program Port: RS-232 DB9 connector (male) can be connected to a DB9 port on a PC. This connector can be used with serial and NetLinx programming commands, as well as other DB9 capable devices, to both upload/download information from the NetLinx Studio program. • Configuration DIPSwitch: Sets the communication parameters for the Program port (see Baud Rate Settings). • ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device. • Ethernet Port: RJ-45 connector provides TCP/IP communication. This is an Auto MDI/MDIX enabled port, which allows you to use either straight-through or crossover Ethernet cables. The Ethernet Port LEDs show communication activity, connection status, speeds, and mode information: • SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. • L/A (link/activity) - Green LED lights On when the Ethernet cables are connected and terminated correctly, and blinks when receiving Ethernet data packets. • AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector that provides data and power to external control devices. Green AXlink LED indicates the state of the AXlink port. • Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector. Included Accessories: • 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025) • 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047) • 6-pin 3.5 mm mini-Phoenix female I/O connector (41-5063) • 8-pin 3.5 mm mini-Phoenix female Relay connector (41-5083) • Installation Kit (KA2105-01): - 8-pin Relay Common Strip - 4 rack mount screws - 4 washers • 2 CC-NIRC NetLinx IR Emitter Cables (FG10-000-11) • 2 removable rack ears (62-2105-07) Other AMX Equipment: • 2-pin 3.5 mm mini-Phoenix male connector (41-5026) • CSB Cable Support Bracket (FG517) • CC-COM Programming Port Cable (FG10-727) • CC-NSER IR/Serial cable (FG10-007-10) • ICSNet daughter card (FG2105-10) • NCK, NetLinx Connector Kit (FG2902) • STS, Serial To Screw Terminal (FG959) • Upgrade Compact Flash (factory programmed with firmware): NXA-CF2NI256M - 256 MB compact flash card (FG2116-47) NXA-CF2NI512M - 512 MB compact flash card (FG2116-48) NXA-CF2NI1G - 1 GB compact flash card (FG2116-49) 4 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Introduction NI-3100 Specifications The NI-3100 (FIG. 3) provides support for 7 RS-232/RS-422/RS-485 Ports, 8 IR/Serial Output ports, 8 Digital Input/Output ports, and 8 Relays. The NI-3100 can be upgraded to provide one ICSHub and two ICSNet ports by either installing the optional ICSNet daughter card (FG2105-10) or purchasing this upgrade as an included feature of the NI3100 Kit (FG2105-15). FIG. 3 NI-3100 NetLinx Integrated Controller (front view) RS-232/422/485 TX/RX LEDs (red/yellow) Relay LEDs (red) IR/Serial LEDs (red) Link/Active-Status-Output-Input LINK/ACT STATUS INPUT OUTPUT 1 2 3 4 5 6 7 TX RX TX RX TX RX TX RX TX RX TX RX TX RX RS - 232 / 422 / 485 1 2 3 4 5 RELAYS 6 7 8 1 2 3 4 5 6 7 8 1 2 IR / SERIAL 3 4 5 6 7 8 I/O I/O LEDs (yellow) Front AXlink LED (green) ICSNet cover plate Rear AXlink port RS-232/422/485 (Ports 1-7) Ethernet IR/Serial (Ports 9-16) Pin 1 2 3 4 5 Relays (Port 8) I/O (Port 17) Program port RS - 232 / 422 / 485 (Ports 1-7) Function Pin Function RXRXD TXD TX+ GND 6 7 8 9 DIP switch RX+ RTS CTS TX- PWR ID Pushbutton FIG. 4 NI-3100 front and rear panel connectors and components NI-2100, NI-3100, NI-4100 Hardware Reference Guide 5 Introduction NI-3100 Specifications Dimensions (HWD): • 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm) Power Requirement: 900 mA @ 12 VDC Memory: • 64 MB SDRAM Compact Flash: 128 MB or more • 2 rack units high • 1 MB Non-volatile (NV) SRAM • AMX may increase Flash size at any time in response to market availability • Upgradeable - see Other AMX Equipment Weight: 4.55 lbs (2.06 kg) Enclosure: Metal with black matte finish Certifications: FCC Part 15 Class B, CE, and IEC 60950 Front Panel LEDs: • LINK/ACT: Green LED blinks when the Ethernet cables are connected and terminated correctly. Also blinks when receiving Ethernet data packets. • Status: Green LED blinks to indicate that the system is programmed and communicating properly. • Output: Red LED blinks when the Controller transmits data, sets channels On and Off, sends data strings, etc. • Input: Yellow LED blinks when the Controller receives data from button pushes, strings, commands, channel levels, etc. • RS-232/422/485: 7 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 7 are transmitting or receiving RS-232, 422, or 485 data. • Relay: • Eight-channel single-pole single-throw relay ports • Each relay is independently controlled. • Supports up to 8 independent external relay devices • Channel range = 1-8 • Each relay can switch up to 24 VDC or 28 VAC @ 1 A Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay termination • IR/Serial: 8 red LEDs light to indicate the IR/Serial channels 1 - 8 are transmitting control data on Ports 9 - 16. LED indictor for each IR port remains lit for the length of time that IR/Serial data is being generated. • I/O: 8 yellow LEDs light when the rear I/O channels 1 - 8 are active. The LED for each I/O port reflects the state of that particular port. Rear Panel Components: • RS-232/422/485 (Ports 1 - 7): 7 RS-232/422/485 control ports using DB9 (male) connectors with XON/ XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-115,200 baud. 6 • ICSNet: 2 RJ-45 connectors for ICSNet interface (provided by optional ICSNet daughter card). • ICSHub Out: RJ-45 connector provides data to a Hub connected to the Controller (provided by optional ICSNet daughter card). • Relay (Port 8): 8-channel single-pole single throw relay ports with each relay being independently controlled and supporting up to 8 independent external relay devices. • Digital I/O (Port 17): 8-channel binary I/O port for contact closure with each input being capable of voltage sensing. Input format is software selectable with interactive power sensing for IR ports. NI-2100, NI-3100, NI-4100 Hardware Reference Guide Introduction NI-3100 Specifications (Cont.) Rear Panel Components (Cont.): • IR/Serial (Ports 9 - 16): 8 IR/Serial control ports support high-frequency carriers of up to 1.142 MHz with each output being capable of two electrical formats: IR or Serial. • 8 IR/Serial data signals can be generated simultaneously. • IR ports support data mode (at limited baud rates and wiring distances). • Program Port: RS-232 DB9 connector (male) can be connected to a DB9 port on a PC. This connector can be used with serial and NetLinx programming commands, as well as other DB9 capable devices, to both upload/download information from the NetLinx Studio program. • Configuration DIP Switch: Sets the communication parameters for the Program port (see Baud Rate Settings). • ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device. • Ethernet Port: RJ-45 connector provides TCP/IP communication. This is an Auto MDI/MDI-X enabled port, which allows you to use either straight-through or crossover Ethernet cables. The Ethernet Port LEDs show communication activity, connection status, speeds, and mode information: • SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. • L/A (link/activity) - Green LED lights On when the Ethernet cables are connected and terminated correctly, and blinks when receiving Ethernet data packets. • AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector that provides data and power to external control devices. Green AXlink LED indicates the state of the AXlink port. • Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector. Included Accessories: • 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025) • 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047) • 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107) • Installation Kit (KA2105-01): - 8-pin Relay Common Strip - 4 rack mount screws - 4 washers • 2 8-pin 3.5 mm mini-Phoenix female Relay connectors (41-5083) • 2 CC-NIRC NetLinx IR Emitter Cables (FG10-000-11) • 2 removable rack ears (62-2105-07) Other AMX Equipment: • 2-pin 3.5 mm mini-Phoenix male connector (41-5026) • CSB Cable Support Bracket (FG517) • CC-NSER IR/Serial cables (FG10-007-10) • ICSNet daughter card (FG2105-10) • NCK, NetLinx Connector Kit (FG2902) • STS, Serial To Screw Terminal (FG959) • Upgrade Compact Flash (factory programmed with firmware): NXA-CF2NI256M - 256 MB compact flash card (FG2116-47) NXA-CF2NI512M - 512 MB compact flash card (FG2116-48) NXA-CF2NI1G - 1 GB compact flash card (FG2116-49) NI-2100, NI-3100, NI-4100 Hardware Reference Guide 7 Introduction NI-4100 Specifications The NI-4100 (FIG. 5) is geared toward those advanced control and automation requirements associated with most complex commercial and residential installations. The NI-4100 provides support for up to 4 NetLinx control cards (such as NXC-COM2, NXC-IRS4, etc.), 7 RS-232/RS-422/RS-485 Ports, 8 IR/Serial Output ports, 8 Digital Input/Output ports, and 8 Relays. The NI-4100’s on-board Master also provides the ability to update installed control card firmware. FIG. 5 NI-4100 NetLinx Integrated Controller (front view) RS-232/422/485 TX/RX LEDs (red/yellow) Relay LEDs (red) Link/Active-Status-Output-Input IR/Serial LEDs (red) LINK/ACT INPUT OUTPUT STATUS 1 2 3 4 5 6 7 TX RX TX RX TX RX TX RX TX RX TX RX TX RX RS - 232 / 422 / 485 1 2 3 4 5 6 7 8 1 2 RELAYS 3 4 5 6 7 8 1 2 IR / SERIAL 3 4 5 6 7 8 I/O I/O LEDs (yellow) Front NetLinx Card slots (1 - 4) ICSNet (2) RS-232/422/485 (Ports 1-7) ICSHub Out AXlink LED (green) AXlink port Rear Relays (Port 8) IR/Serial I/O (Port 17) (Ports 9-16) DIP switch Ethernet Pin 1 2 3 4 5 RS - 232 / 422 / 485 (Ports 1-7) Function Pin Function RXRXD TXD TX+ GND 6 7 8 9 RX+ RTS CTS TX- ID Program port ON CardFrame DIP switch Slot 1-4 connectors ID Pushbutton PWR FIG. 6 NI-4100 front and rear panel connectors and components 8 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Introduction NI-4100 Specifications Dimensions (HWD): • 5.21" x 17.00" x 9.60" (13.23 cm x 43.18 cm x 24.27 cm) • 3 rack units high Power Requirement: • 900 mA @ 12 VDC Memory: • 64 MB SDRAM Compact Flash: 128 MB or more • 1 MB Non-volatile (NV) SRAM • AMX may increase Flash size at any time in response to market availability • Upgradeable - see Other AMX Equipment Weight: 9.15 lbs (4.15 kg) Enclosure: Metal with black matte finish Certifications: FCC Part 15 Class B, CE, and IEC 60950 Front Panel LEDs/Slots: • LINK/ACT: Green LED blinks when the Ethernet cables are connected and terminated correctly. Also blinks when receiving Ethernet data packets. • Status: Green LED blinks to indicate that the system is programmed and communicating properly. • Output: Red LED blinks when the Controller transmits data, sets channels On and Off, sends data strings, etc. • Input: Yellow LED blinks when the Controller receives data from button pushes, strings, commands, channel levels, etc. • RS-232/422/485: 7 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 7 are transmitting or receiving RS-232, 422, or 485 data. • Relay: 8 red LEDs light to indicate the relay channels 1 - 8 are active (closed). These LEDs reflect the state of the relay on Port 8. • IR/Serial: 8 red LEDs light to indicate the IR/Serial channels 1 - 8 are transmitting control data on Ports 9 - 16. LED indictor for each IR port remains lit for the length of time that IR/Serial data is being generated. • I/O: 8 yellow LEDs light when the rear I/O channels 1 - 8 are active. The LED for each I/O port reflects the state of that particular port. • NetLinx Control Card Slots 1 - 4: Accepts up to 4 compatible NetLinx Cards: such as the NXC-COM2, NXCI/O10, etc. Rear Panel Components: • RS-232/422/485 (Ports 1 - 7): 7 RS-232/422/485 control ports using DB9 (male) connectors with XON/ XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-115,200 baud. • ICSNet: 2 RJ-45 connectors for ICSNet interface (provided by optional ICSNet daughter card). • ICSHub Out: RJ-45 connector provides data to a Hub connected to the Controller (provided by optional ICSNet daughter card). • Relay (Port 8): • Eight-channel single-pole single throw relay ports • Each relay is independently controlled. • Supports up to 8 independent external relay devices • Channel range = 1-8 • Each relay can switch up to 24 VDC or 28 VAC @ 1 A Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay termination • Digital I/O (Port 17): 8-channel binary I/O port for contact closure with each input being capable of voltage sensing. Input format is software selectable with interactive power sensing for IR ports. • IR/Serial (Ports 9 - 16): 8 IR/Serial control ports support high-frequency carriers of up to 1.142 MHz with each output being capable of two electrical formats: IR or Serial. • 8 IR/Serial data signals can be generated simultaneously. • IR ports support data mode (at limited baud rates and wiring distances). NI-2100, NI-3100, NI-4100 Hardware Reference Guide 9 Introduction NI-4100 Specifications (Cont.) Rear Panel Components (Cont.): • Program Port: RS-232 DB9 connector (male) can be connected to a DB9 port on a PC. This connector can be used with serial and NetLinx programming commands, as well as other DB9 capable devices, to both upload/download information from the NetLinx Studio program. • Configuration DIPSwitch: Sets the communication parameters for the Program port (see Baud Rate Settings). • ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device. • Ethernet Port: RJ-45 connector provides TCP/IP communication. This is an Auto MDI/ MDI-X enabled port, which allows you to use either straight-through or crossover Ethernet cables. The Ethernet Port LEDs show communication activity, connection status, speeds, and mode information: • SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. • L/A (link/activity) - Green LED lights On when the Ethernet cables are connected and terminated correctly, and blinks when receiving Ethernet data packets. • AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector that provides data and power to external control devices. Green AXlink LED indicates the state of the AXlink port. • Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector. • CardFrame #DIP Switch: Sets the starting address for the Control Cards in the CardFrame. (Factory default CardFrame DIP switch value = 0). The Control Card address range is 1-3064. • Control Card Connectors (1-4): 20-pin (male) connectors that connect the Control Cards and external equipment to the CardFrame. Included Accessories: • 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025) • 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047) • 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107) • Installation Kit (KA2105-01): - 8-pin Relay Common Strip - 4 rack mount screws - 4 washers • 2 8-pin 3.5 mm mini-Phoenix (female) Relay connectors (41-5083) • 2 CC-NIRC NetLinx IR Emitter Cables (FG10-000-11) • 2 removable rack ears (62-2105-07) Other AMX Equipment: • 2-pin 3.5 mm mini-Phoenix male connector (41-5026) • CSB Cable Support Bracket (FG517) • CC-NSER IR/Serial cables (FG10-007-10) • NCK, NetLinx Connector Kit (FG2902) • STS, Serial To Screw Terminal (FG959) • Upgrade Compact Flash (factory programmed with firmware): NXA-CF2NI256M - 256 MB compact flash card (FG2116-47) NXA-CF2NI512M - 512 MB compact flash card (FG2116-48) NXA-CF2NI1G - 1 GB compact flash card (FG2116-49) 10 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Introduction Related Documents For information on using the on-board Web Console, as well as NetLinx send commands and terminal communications to configure the NI Controllers, refer to the NetLinx Integrated Controller WebConsole & Programming Guide. All product documentation is available to view or download from www.amx.com. NI-2100, NI-3100, NI-4100 Hardware Reference Guide 11 Introduction 12 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Installation and Upgrading Installation and Upgrading Installing NetLinx Control Cards (NI-4100 Only) NetLinx Cards can be installed into the front card slots. The cards mount horizontally through the card slot openings on the front of the enclosure. 1. Discharge the static electricity from your body, by touching a grounded object. 2. Remove the three screws by turning them in a counter-clockwise direction and then remove the faceplate (FIG. 7). Thumbscrews NXC Card Slot faceplate FIG. 7 NI-4100 front faceplate 3. Align the edges of the card with the internal guide slots and gently slide the card all the way into the slot (FIG. 8). Card slots Sample NXC cards Internal Guide slots FIG. 8 Sample NXC cards inserted into an NI-4100 unit 4. Carefully apply a small amount of force to insert the cards into their respective connectors. If the cards have LEDs on them, those LEDs will initiate a lighting sequence to indicate they are receiving power and are communicating with the Controller. 5. Re-align the faceplate and secure it to the chassis by inserting the three screws by turning them in a clockwise direction and securing the front plate to the Integrated Controller. 6. Install all rear connectors and apply power. NI-2100, NI-3100, NI-4100 Hardware Reference Guide 13 Installation and Upgrading If the cards do not appear in the NetLinx Studio’s Workspace window for the selected Master System number: give the system time to detect the inserted cards (and refresh the system) and/or cycle power to the unit. Setting the NetLinx Control Card Addresses (NI-4100 Only) The 8-position CardFrame Number DIP switch (located on the rear of the NI-4100) sets the starting address (the device number in the D:P:S specification) for the Control Cards installed in the CardFrame. The address range is 1-3064. The factory default CardFrame DIP switch value = 0 (all CardFrame DIP switches in the OFF position). The formula for setting the starting address is: (DIP switch address x 12) + Card slot Number (1-12) = Card address For example: DIP switch setting, 00010101: (0 + 0 + 0 + 96 + 0 + 384 + 1536) + SLOT #(ex:1) = 2017. A card in slot number 1 would be device address 2017. 1. Set the CardFrame Number DIP switch based on the information listed in the table below. Position 1 2 3 4 5 6 7 8 Value 12 24 48 96 192 384 768 1536 ON position 2. Cycle power to the unit for approximately 5 seconds. This allows the unit to read the new device number settings. Device:Port:System (D:P:S) A device is any hardware component that can be connected to an AXlink or ICSNet bus. Each device must be assigned a unique number to locate that device on the bus. The NetLinx programming language allows numbers in the range 1-32,767 for ICSNet (255 for AXlink). Only the Device value can be set through the DIP switch settings mentioned above. NetLinx requires a Device:Port:System (D:P:S) specification. This D:P:S triplet can be expressed as a series of constants, variables separated by colons, or a DEV structure. For example: STRUCTURE DEV { INTEGER Number // Device number INTEGER Port // Port on device INTEGER System // System the device belongs to } The D:P:S notation is used to explicitly represent a device number, port and system. For example, 128:1:0 represents the first port on device 128 on this system. If a device is declared in a NetLinx program with just the Device number (System and Port are omitted), the NetLinx Compiler assumes it has a Port number of 1 and a System number of 0. However, you should convert all existing device declarations using the D:P:S (Device:Port:System) notation. This enables certain NetLinx specific debugging features and can help pinpoint other possibly obscure errors. Here's the syntax: 14 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Installation and Upgrading NUMBER:PORT:SYSTEM where: NUMBER: 16-bit integer represents the device number PORT: 16-bit integer represents the port number (in the range 1 through the number of ports on the Controller or device) SYSTEM: 16-bit integer represents the system number (0 = this system) Removing NetLinx Control Cards (NI-4100 Only) To install NetLinx Control Card: 1. Discharge any static electricity from your body, by touching a grounded object and unplug all connectors (if any) from the unit. 2. Remove the three faceplate screws by turning them in a counter-clockwise direction. 3. Remove the faceplate from the front plate (FIG. 7 on page 13). 4. Gently grasp the rear edge of the control card and gently pull it out from the unit (along the internal guide slots). 5. Re-secure the faceplate by inserting the three faceplate screws by turning them in a clockwise direction and securing the front plate to the Integrated Controller. 6. Re-apply power and other connections as necessary. Compact Flash Upgrades The NetLinx Integrated Controllers are shipped with a default 32 MB Compact Flash module. It is recommended that ANY MEMORY UPGRADE should be done prior to any installation. Refer to the following accessing and installation sections for more information. The Compact Flash card is factory programmed with specific Controller firmware. These cards can be ordered from AMX in several different upgrade sizes (see the following table): Optional Compact Flash Upgrades Product Name Description NXA-CFNI64M 64 MB compact flash card (FG2116-31) NXA-CFNI128M 128 MB compact flash card (FG2116-32) NXA-CFNI256M 256 MB compact flash card (FG2116-33) NXA-CFNI512M 512 MB compact flash card (FG2116-34) NXA-CFNI1G 1 GB compact flash card (FG2116-35) Accessing The Internal Components On An Integrated Controller 1. Carefully detach all connectors from the rear of the unit. 2. Remove the chassis housing screws from both the sides and top of the Controller, as shown in FIG. 9 by using a grounded screwdriver turning in a counter-clockwise rotation. The NI-2100 and NI-3100 have six screws on top and three on each side. The NI-4100 has six screws on top and four on each side. NI-2100, NI-3100, NI-4100 Hardware Reference Guide 15 Installation and Upgrading Chassis housing screws (top) - 6 on top - sides vary per model Mounting Brackets Compact Flash Compact Flash insert location Chassis housing screws (side) - 4 on each side of the NI-4100 - 3 on each side of the NI-3100/2100 NXC Card Slot faceplate NXC Card Slots FIG. 9 Location of the Compact Flash within a sample Integrated Controller 3. Carefully pull-up and remove the housing up and away from the Controller to expose the internal circuit board (FIG. 9). 4. Refer to the followingInstallation of Compact Flash Upgradesfor detailed replacement information. Installation of Compact Flash Upgrades 1. Discharge any static electricity from your body by touching a grounded metal object. 2. Locate the 32 MB Compact Flash card on the main board. For more detailed information on component locations, refer to FIG. 9. 3. Insert the tip of a grounded flathead screwdriver into one of the Card Removal Grooves (located on either side of the card), and gently pry the card out of the slot. Repeat this process on the opposite card removal groove. This alternating action causes the card to "wiggle" away from the on-board connector pins. 4. Slip your finger into the opening between the connector pins and the card, and push the card out to remove it. 5. Remove the upgrade card from it’s anti-static bag. 6. Insert the upgrade card into the connector opening with the arrow facing towards the pins, then push it in firmly until the contact pins are completely inside the flash card and securely attached to the connector (FIG. 10). 16 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Installation and Upgrading Under-side groove located below Card Removal Grooves Insert with arrow facing towards the connector pins FIG. 10 Removing the Compact Flash card 7. To complete the upgrade process, close and re-secure the Integrated Controller enclosure using the procedures outlined in the following section. Any new internal card upgrade is detected by the Controller only after power is cycled. Closing and Securing the Outer Housing Once the card has been replaced, close and re-secure the outer housing: 1. Align the cover back over the unit and gently slide-down the chassis until the openings are aligned over their respective openings along both the sides and top of the unit. 2. Insert and secure the chassis housing screws back into their respective locations, as shown in FIG. 9 by using a grounded screwdriver. 3. Re-install all connectors and apply power to the unit. Installing Into An Equipment Rack Use the rack-mounting brackets (supplied) for equipment rack installations. Remove the mounting brackets for flat surface installations. Before completing the install process, it is recommended that you complete any firmware upgrade of the NetLinx Control Cards. This upgrade involves physically cycling power to the unit and can become cumbersome if the unit is already installed into a rack. Refer to the NI Series NetLinx Integrated Controllers WebConsole & Programming Guide (available online at www.amx.com) for detailed instructions. 1. Discharge the static electricity from your body by touching a grounded object. 2. Position and install the mounting brackets, as shown in FIG. 11, using the screws supplied with the unit. The mounting brackets can be rotated to accommodate your mounting needs. NI-2100, NI-3100, NI-4100 Hardware Reference Guide 17 Installation and Upgrading Install screws Bracket Rack Mounting Holes FIG. 11 Mounting Integrated Controller into an equipment rack 3. Thread the cables through the opening in the equipment rack. Allow for enough slack in the cables to accommodate for movement during the installation process. 4. Reconnect all cables to their appropriate source/terminal locations. Refer to theConnections and Wiring section on page 19 for more detailed wiring and connection information. Verify that the terminal end of the power cable is not connected to the a power supply before plugging in the 2-pin power connector. To prevent repetition of the installation, test the incoming wiring by connecting the Controller’s connectors to their terminal locations and applying power. Verify that the unit is receiving power and functioning properly. Disconnect the terminal end of the power cable from the connected 12 VDC-compliant power supply. 5. Slide the unit into the rack until the attachment holes, along both sides, align to their corresponding locations on the mounting brackets, as shown in FIG. 11. 6. Secure the AC-RK to the rack by using the four #10-32 screws (80-0186) and four #10 washers (80-0342) supplied in the kit. 7. Apply power to the unit to complete the installation. 18 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Connections and Wiring Connections and Wiring Setting the Configuration DIP Switch (for the Program Port) Prior to installing the Controller, use the Configuration DIP switch to set the baud rate used by the Program port for communication. The Configuration DIP switch is located on the front of the Integrated Controllers. Baud Rate Settings Before programming the on-board Master, make sure the baud rate you set matches the communication parameters set on both your PC’s COM port and those set through your NetLinx Studio v 2.4. By default, the baud rate is set to 38,400 (bps). Baud Rate Settings on the Configuration DIP Switch Baud Rate Position 5 Position 6 Position 7 Position 8 9600 bps OFF ON OFF ON 38,400 bps (default) OFF ON ON ON 57,600 bps ON OFF OFF OFF 115,200 bps ON ON ON ON Note the orientation of the Configuration DIP Switch and the ON position label. DIP switches 2,3, and 4 must remain in the OFF position at all times. Program Run Disable (PRD) Mode You can also use the Program port’s Configuration DIP switch to set the on-board Master to Program Run Disable (PRD) mode according to the settings listed in the table below. PRD Mode Settings PRD Mode Position 1 Normal mode (default) OFF PRD Mode ON The PRD mode prevents the NetLinx program stored in the on-board Master from running when you power up the Integrated Controller. This mode should only be used when you suspect the resident NetLinx program is causing inadvertent communication and/or control problems. If necessary, place the on-board Master in PRD mode and use the NetLinx Studio v 2.4 program to resolve the communication and/or control problems with the resident NetLinx program. Then download the new NetLinx program and try again. NI-2100, NI-3100, NI-4100 Hardware Reference Guide 19 Connections and Wiring Think of the PRD Mode (On) equating to a PC’s SAFE Mode setting. This mode allows a user to continue powering a unit, update the firmware, and download a new program while circumventing any problems with a currently downloaded program. Power must be cycled to the unit after activating/deactivating this mode on the Program Port DIP switch #1. Working With the Configuration DIP Switch 1. Disconnect the power supply from the 2-pin PWR (green) connector on the rear of the NetLinx Integrated Controller. 2. Set DIP switch positions according to the information listed in theBaud Rate Settings on the Configuration DIP Switch andPRD Mode Settings tables. 3. Reconnect the 12 VDC-compliant power supply to the 2-pin 3.5 mm mini-Phoenix PWR connector. Setting the CardFrame DIP Switch (NI-4100 Only) Refer to the Setting the NetLinx Control Card Addresses (NI-4100 Only) section on page 14 for a detailed explanation on this process. Program Port Connections and Wiring The Integrated Controllers are equipped with a Program port located on the front of the unit. Use an RS232 programming cable to establish a connection between this Program port to your PC's COM port. This connection provides communication with the NetLinx Integrated Controller. Then you can download NetLinx programs to this on-board Master using the NetLinx Studio v 2.4 software program. Refer to the NetLinx Studio instruction manual for programming instructions. The following table shows the rear panel Program Port connector (male), pinouts, and signals. Program Port, Pinouts, and Signals Program Port Connector 9 8 5 4 3 2 1 Pin Signal 2 RX 3 TX 5 GND 7 RTS 8 CTS 7 6 Male When wiring the 422/485 connections, do NOT use pre-made 9-wire cable or connect the wire in the cable to any connection that will not be used by the DB9 serial port. Only use wiring that connects the needed pins. 20 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Connections and Wiring Modes and Front Panel LED Blink Patterns The following table lists the modes and blink patterns for the front panel LEDs associated with each mode. These patterns are not evident until after the unit is powered. Modes and LED Blink Patterns LEDs and Blink Patterns STATUS (green) OUTPUT INPUT (red) (yellow) Mode Description OS Start Starting the operating system (OS). On On On Boot On-board Master is booting. On Off On Contacting DHCP server On-board Master is contacting a DHCP server for IP configuration information. On Off Fast Blink Unknown DHCP server On-board Master could not find the DHCP server. Fast Blink Off Off Downloading Boot firmware Downloading Boot firmware to the Master’s on-board flash memory. Fast Blink Fast Blink Fast Blink No program running There is no program loaded, or the program is disabled. On Normal Normal Normal On-board Master is functioning normally. 1 blink per second Indicates activity Do not cycle power during this process! Indicates activity Port Assignments and Functionality The Port Assignments are as follows: NI-2100 Port Assignments NI-3100/4100 Port Assignments Port ICSP Port # Port ICSP Port # Serial Port #1 1 Serial Port #1 1 Serial Port #2 2 Serial Port #2 2 Serial Port #3 3 Serial Port #3 3 Relays Ports (1-4) 4 Serial Port #4 4 IR/Serial Port #1 5 Serial Port #5 5 IR/Serial Port #2 6 Serial Port #6 6 IR/Serial Port #3 7 Serial Port #7 7 IR/Serial Port #4 8 Relays Ports (1-8) 8 I/O Port 9 IR Serial Port #1 9 IR Serial Port #2 10 NI-2100, NI-3100, NI-4100 Hardware Reference Guide IR Serial Port #3 11 IR Serial Port #4 12 IR Serial Port #5 13 IR Serial Port #6 14 IR Serial Port #7 15 IR Serial Port #8 16 I/O Port 17 21 Connections and Wiring AXlink Port and LED All NI units have an AXlink port and adjacent status LED (FIG. 12). This port allows the NI to support AMX Legacy AXlink devices such as G3 touch panels (ex: CP4/A) and PosiTrack Pilot devices. A green LED shows AXlink data activity. When the AXlink port is operating normally, blink patterns include: Off - No power, or the controller is not functioning properly 1 blink per second - Normal operation. 3 blinks per second - AXlink bus error. Check all AXlink bus connections. FIG. 12 AXlink connector and LED The AXlink port can be used to supply power to downstream AXlink-compatible devices as long as both the power required is LESS THAN 2 Amps total and the external power supply feeding the NI unit has the necessary power capability. Wiring Guidelines The Integrated Controllers use a 12 VDC-compliant power supply to provide power through the rear 2pin 3.5 mm mini-Phoenix PWR connector. Use the power requirements referenced in the product’s Specifications table to determine the power draw. The incoming PWR and GND cable from the power supply must be connected to the corresponding locations within the PWR connector. This unit should only have one source of incoming power. Using more than one source of power to the Controller can result in damage to the internal components and a possible burn out. Apply power to the unit only after installation is complete. Wiring length guidelines Refer to the following tables for the wiring length information used with the different types of NetLinx Integrated Controllers: Wiring Guidelines - NI-2100 (@ 700 mA) Wire size Maximum wiring length 18 AWG 154.83 feet (47.19 meters) 20 AWG 98.30 feet (29.96 meters) 22 AWG 63.40 feet (19.32 meters) 24 AWG 38.68 feet (11.79 meters) Wiring Guidelines - NI-3100 & NI-4100 (@ 900) mA 22 Wire size Maximum wiring length 18 AWG 120.41 feet (39.70 meters) 20 AWG 76.45 feet (23.30 meters) 22 AWG 49.36 feet (15.04meters) 24 AWG 30.08 feet (9.17 meters) NI-2100, NI-3100, NI-4100 Hardware Reference Guide Connections and Wiring Preparing Captive Wires You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires. Never pre-tin wires for compression-type connections. 1. Strip 0.25 inch (6.35 mm) of insulation off all wires. 2. Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector types described in this section). 3. Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively doing so may strip the threads and damage the connector. Wiring a Power Connection To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming PWR and GND cables from the external source must be connected to their corresponding locations on connector (FIG. 13). 1. Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable. Match the wiring locations of the +/- on both the power supply and the terminal connector. 2. Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may strip the threads and damage the connector. 3. Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the external 12 VDC-compliant power supply. PWR + Power Supply GND To the Integrated Controller FIG. 13 2-pin mini-Phoenix connector wiring diagram (direct power) Using the 4-Pin Mini-Phoenix Connector For Data and Power Connect the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector to an external NetLinx device as shown in FIG. 14. To the Integrated Controller’s AXlink/PWR connector To the external AXlink device Top view PWR + AXM/RX GND - AXP/TX PWR + AXM/RX GND - AXP/TX Top view FIG. 14 Mini-Phoenix connector wiring diagram (direct data and power) NI-2100, NI-3100, NI-4100 Hardware Reference Guide 23 Connections and Wiring Using the 4-pin Mini-Phoenix Connector For Data With External Power To use the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector for data communication and power transfer, the incoming PWR and GND cable from the 12 VDC-compliant power supply must be connected to the AXlink cable connector going to the Integrated Controller. FIG. 15 shows the wiring diagram. Always use a local power supply to power the Integrated Controller unit. To the Integrated Controller’s AXlink/PWR connector PWR (+) GND (-) Local +12 VDC power supply (coming from an external power supply) To the external AXlink device Top view AXM/RX GND - AXP/TX AXM/RX GND - AXP/TX Top view FIG. 15 4-pin mini-Phoenix connector wiring diagram (using external power source) When you connect an external power supply, do not connect the wire from the PWR terminal (coming from the external device) to the PWR terminal on the Phoenix connector attached to the Controller unit. Make sure to connect only the AXM, AXP, and GND wires to the Controller’s Phoenix connector when using an external power supply. Make sure to connect only the GND wire on the AXlink/PWR connector when using a separate 12 VDC power supply. Do not connect the PWR wire to the AXlink connector’s PWR (+) opening. DB9 Device Port: Connections and Wiring FIG. 16 shows the connector pinouts for the rear RS-232/RS-422/RS-485 (DB9) Device Ports. These ports support most standard RS-232 communication protocols for data transmission. This figure gives a visual representation of the wiring specifications for the RS-232/422/485 Device connectors. Refer to the rear of the unit for more detailed connector pinout information. DB9 Serial Port pinouts (male connector) 9 8 5 4 3 2 1 7 6 RS-232 RS-422 RS-485 Pin 2: RX signal Pin 3: TX signal Pin 5: GND Pin 7: RTS Pin 8: CTS Pin 1: RX Pin 4: TX + Pin 5: GND Pin 6: RX + Pin 9: TX - Pin 1: A (strap to 9) Pin 4: B (strap to 6) Pin 5: GND Pin 6: B (strap to 4) Pin 9: A (strap to 1) Male FIG. 16 RS-232/422/485 DB9 (male) connector pinouts for the rear Device Ports 24 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Connections and Wiring The table below provides information about the connector pins, signal types, and signal functions. This table’s wiring specifications are applicable to the rear RS-232/422/485 Device Port connectors on the: NI-2100 (Ports 1-3) NI-4100/NI-3100 (Ports 1-7) RS-232/422/485 Device Port Wiring Specifications Pin Signal Function RS-232 RS-422 RS-485 1 RX- Receive data 2 RXD Receive data X 3 TXD Transmit data X 4 TX+ Transmit data 5 GND Signal ground 6 RX+ Receive data 7 RTS Request to send X 8 CTS Clear to send X 9 TX- Transmit data X X X (strap to pin 9) X X (strap to pin 6) X X X (strap to pin 4) X X (strap to pin 1) ICSNet Port: Connections and Wiring The NI Controller must be equipped with the available ICSNet connectors for this functionality to be active. The following tables show the signal and pinouts/pairing information: ICSNet RJ-45 Signals Pin Signal-Master Signal-Device 1 TX + RX + 2 TX - RX - 3 N/A N/A 4 GND GND 5 N/A N/A 6 N/A N/A 7 RX + TX + 8 RX - TX - RJ-45 Pinout Information (EIA/TIA 568 B) Pin Wire Color Polarity Function 1 Orange/White + Transmit 2 Orange - Transmit 3 Green/White - Mic 4 Blue - Ground 5 White/Blue + 12 VDC 6 Green + Mic 7 White/Brown + Receive 8 Brown - Receive NI-2100, NI-3100, NI-4100 Hardware Reference Guide TIA 568B 25 Connections and Wiring 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 (female) (male) RJ-45 connector - pin configurations Unlike the ICSNet ports, the ICSHub connections require a specific polarity. The IN/OUT configuration, on the hub ports, was implemented to use the same cables as ICSNet, but these ports need TX and RX crossed. You must connect an OUT to an IN, or an IN to an OUT port. This is done simply to keep the polarity straight. The Hub bus is still a bus. All Hub connections are bi-directional. ICSHub OUT Port: Connections and Wiring The NI Controller must be equipped with the available ICSNet connectors for this functionality to be active. The following table describes the pinout/signal information for the ICSHub OUT port located on the rear panel of the Integrated Controller. ICSHub OUT Pinouts and Signals Pin Signal Color 1 RX + orange-white 2 RX - orange 3 ------ ------ 4 ------ ------ 5 ------ ------ 6 ------ ------ 7 TX + brown-white 8 TX - brown Relay Port: Connections and Wiring You can connect up to 8 independent external relay devices on both the NI-4100 and NI-3100 units (4 on the NI-2100) to the Relay connectors on the Integrated Controller. Connectors labeled A are for common; B are for output. Each relay is isolated and normally open. A metal commoning strip is supplied with each Integrated Controller to connect multiple relays. Relay Connections Use A for common and B for output (FIG. 17). Each relay is isolated and normally open. A metal connector strip is also provided to common multiple relays. 26 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Connections and Wiring NI-4100/NI-3100 relay connector configuration (Port 8) NI-2100 relay connector configuration (Port 4) FIG. 17 RELAY connector (male) Input/Output (I/O) Port: Connections and Wiring The I/O port responds to either switch closures, voltage level (high/low) changes, or it can be used for logic-level outputs. NI-2100 I/O connector configuration (Port 9) NI-4100/NI-3100 I/O connector configuration (Port 17) FIG. 18 INPUT/OUTPUT (I/O) connector (male) A contact closure between the GND and an I/O port is detected as a Push. When used for voltage inputs, the I/O port detects a low signal (0 - 1.5 VDC) as a Push, and a high signal (3.5 - 5 VDC) as a Release (this IO port uses 5V logic but can handle up to 12V without harm). When used for outputs, the I/O port acts as a switch to GND and is rated for 200mA @ 12 VDC. The NI-2100 can use up to 4 I/O ports The NI-3100 and NI-4100 can use up to 8 I/O ports The PWR pin provides +12 VDC @ 200 mA and is designed as a power output for the PCS Power Current Sensors, VSS2 Video Sync Sensors (or equivalent). The GND connector is a common ground and is shared by all I/O ports. A common ground is shared with I/O ports 1 - 8 (NI-3100/NI-4100) or with I/O ports 1 - 3 (NI-2100). I/O Port Wiring Specifications NI-4100 and NI-3100 I/O Port Wiring Specifications NI-2100 Pin Signal Pin 1 GND Signal GND 1 GND Signal GND 2 I/O 1 Input/Output 2 I/O 1 Input/Output 3 I/O 2 Input/Output 3 I/O 2 Input/Output 4 I/O 3 Input/Output 4 I/O 3 Input/Output 5 I/O 4 Input/Output 5 I/O 4 Input/Output 6 I/O 5 Input/Output 6 12 VDC PWR 7 I/O 6 Input/Output 8 I/O 7 Input/Output Function 9 I/O 8 Input/Output 10 12 VDC PWR NI-2100, NI-3100, NI-4100 Hardware Reference Guide Signal Function 27 Connections and Wiring IR/Serial Port: Connections and Wiring You can connect up to eight IR- or Serial-controllable devices to the IR/Serial connectors on the rear of the NI-4100 and NI-3100 and up to four on the NI-2100 (FIG. 19). These connectors accept an IR Emitter (CC-NIRC) that mounts onto the device's IR window, or a miniplug (CC-NSER) that connects to the device's control jack. You can also connect a data 0 - 5 VDC device. These units come with two CC-NIRC IR Emitters (FG10-000-11). NI-2100 IR/Serial connector configuration (Port 5-8) NI-4100/NI-3100 IR/Serial connector configuration (Port 9-16) FIG. 19 IR/SERIAL (male) The IR/Serial connector wiring specifications are listed in the following table. IR/Serial Connector Wiring Specifications (per Port) Number of NI-4100/3100 NI-2100 IR connections Port # Port # Signal Function 1 GND (-) Signal GND 9 5 Signal 1 (+) IR/Serial data 2 10 6 GND (-) Signal GND Signal 2 (+) IR/Serial data 3 11 7 GND (-) 4 12 8 GND (-) 1 2 3 4 5 6 7 8 Signal GND Signal 3 (+) IR/Serial data Signal GND Signal 4 (+) IR/Serial data 5 13 N/A GND (-) Signal GND Signal 5 (+) IR/Serial data 6 14 N/A GND (-) 7 15 N/A GND (-) 8 16 N/A GND (-) Signal GND 1 2 3 4 5 6 7 8 Signal 6 (+) IR/Serial data Signal GND Signal 7 (+) IR/Serial data Signal GND Signal 8 (+) IR/Serial data NetLinx Control Card Slot Connector (NI-4100 only) FIG. 20 shows the 20-pin (male) connector that provides connection to the NetLinx Control Cards. SLOT 1 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 FIG. 20 NetLinx Control Card 20-pin connector 28 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Connections and Wiring Ethernet/RJ-45 Port: Connections and Wiring NI-x100 Controllers feature an Auto MDI/MDI-X Ethernet port. This provides the option of using either a standard (straight through), or a crossover Ethernet cable to communicate with a PC - both cable types will work. The following table lists the pinouts, signals, and pairing for the Ethernet connector. Ethernet RJ-45 Pinouts and Signals Pin Signals Connections Pairing 1 TX + 1 --------- 1 2 TX - 2 --------- 2 3 RX + 3 --------- 3 4 no connection 4 --------- 4 Blue 5 no connection 5 --------- 5 Blue-White 6 RX - 7 no connection 7 --------- 7 Brown-White 8 no connection 8 --------- 8 Brown 6 --------- 6 Color 1 --------- 2 Orange-White Orange 3 --------- 6 Green-White Green FIG. 21 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable. FIG. 21 RJ-45 wiring diagram Ethernet LEDs L/A - Link/Activity LED lights (green) when the Ethernet cables are connected and terminated correctly. SPD - Speed LED lights (yellow) when the connection speed is 100 Mbps and turns Off when speed is 10 Mbps. FIG. 22 Ethernet LEDs NI-2100, NI-3100, NI-4100 Hardware Reference Guide 29 Connections and Wiring Ethernet Ports Used By the Integrated Controller Ethernet Port Descriptions Port type Description Standard Port # FTP The on-board Master has a built-in FTP server. 21/20 (TCP) SSH The SSH port functions using the same interface as Telnet but over a 22 (TCP) secure shell where it uses SSL as a mechanism to configure and diagnose a NetLinx system. This port value is used for secure Telnet communication. Note: SSH version 2 is only supported. Telnet The NetLinx Telnet server provides a mechanism to configure and diagnose a NetLinx system. 23 (TCP) For maximum flexibility, the Master can be configured to utilize a different port than 23, or disable Telnet completely from either Telnet or the Program Port located on the rear of the Master itself. Once disabled, the only way to enable Telnet again is from the Master’s Program port. HTTP The Master has a built-in web server that complies with the HTTP 1.0 specification and supports all of the required features of HTTP v1.1. 80 (TCP) This port is used for unsecure HTTP Internet communication between the web browser’s UI and the target Master. HTTPS/SSL This port is used by a web browser to securely communicate between the web server UI and the target Master. This port is also used to simultaneously encrypt this data using the SSL certificate information on the Master as a key. 443 (TCP) ICSP 1319 (UDP/TCP) Peer-to-peer protocol used for both Master-to-Master and Master-todevice communications. For maximum flexibility, the Master can be configured to utilize a different port than 1319, or disable ICSP over Ethernet completely from either Telnet or the Program Port located on the rear of the Master itself. This type of communication is used by the various AMX product for communication amongst themselves. integration! Solutions This feature on the Master uses, by default, port 10500 for the XML based communication protocol. This port is connected to by the client web browser’s JVM when integration! Solutions control pages are retrieved from the on-board Master’s web server. 10500 (TCP) For maximum flexibility, the on-board Master can be configured to utilize a different port than 10500 or to disable integration! Solutions completely. 30 NI-2100, NI-3100, NI-4100 Hardware Reference Guide Connections and Wiring NI-2100, NI-3100, NI-4100 Hardware Reference Guide 31 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without notice at any time. ©2009 1/2009 It’s Your World - Take Control™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • www.amx.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2009:01:09 11:43:06Z Creator Tool : FrameMaker 8.0 Modify Date : 2009:01:09 12:53:50-06:00 Metadata Date : 2009:01:09 12:53:50-06:00 Format : application/pdf Creator : priddell Title : 0602998 NI2100 3100 4100 Hardware.book Document ID : uuid:4d13bdfe-a03c-4d02-8f46-d5ed1287b28b Instance ID : uuid:258b98c4-1c68-4b8b-bae6-cfca1d41ad23 Page Count : 36 Author : priddellEXIF Metadata provided by EXIF.tools