Anaren 707MS1 A highly‐integrated, embedded Wi‐Fi module User Manual Corporate Backgrounder
Anaren Inc A highly‐integrated, embedded Wi‐Fi module Corporate Backgrounder
Anaren >
Contents
- 1. Users Manual 1
- 2. Users Manual 2
Users Manual 1
ReZolt® RZ707 Em-FiTM Module User Manual ReZolt Confidential Revision 0.1 Aug 13, 2012 ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 ReZolt reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and platforms at any time and to discontinue any product or platform without notice. ReZolt assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using ReZolt products. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. ReZolt does not warrant or represent that any license, either express or implied, is granted under any ReZolt patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which ReZolt products or platforms are used. Information that ReZolt publishes regarding third-party products or services does not constitute a license from ReZolt to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from ReZolt under the patents or other intellectual property of ReZolt. ReZolt assumes no liability whatsoever, and provides no warranty, express or implied, relating to the sale or license of ReZolt products and platforms or engineering services provided by ReZolt. ReZolt products and platforms are not authorized for use in safety-critical applications (such as medical, life-saving or life-sustaining applications) where a failure of the ReZolt product would reasonably be expected to cause severe personal injury or death. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products. ReZolt may make changes to the product specifications and descriptions at any time without notice. ReZolt Confidential Revision 0.1 Dec 1, 2011 ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 Table of Contents 1. Introduction ........................................................................................................................................ 4 1.1 Intended Audience and Reading Suggestions ........................................................................ 4 1.2 Scope of the Document .............................................................................................................. 4 RZ707MS Overview ........................................................................................................................... 5 2.1 Target Applications .................................................................................................................... 5 2.2 Highlights .................................................................................................................................... 5 2.3 Features ....................................................................................................................................... 5 2.4 System Architecture ................................................................................................................... 6 Pin Description ................................................................................................................................... 8 Electrical Characteristics ................................................................................................................... 9 4.1 Absolute Maximum Ratings ..................................................................................................... 9 4.2 Operating Conditions ................................................................................................................ 9 4.3 Low-Power State Characteristics ............................................................................................. 9 Installation Guidelines .................................................................................................................... 11 5.1 Layout Guidelines .................................................................................................................... 11 5.2 Surface Mount Assembly......................................................................................................... 12 Limitations ........................................................................................................................................ 13 Revision History ....................................................................................................................................... 14 ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 1. Introduction ReZolt provides an embedded Wi-Fi module, RZ707MS, to enable low-power Embedded Wi-Fi (Em-FiTM) communication on deeply embedded devices. RZ707MS is a component of Em-Fi Platform from ReZolt Corporation. This document describes hardware specification of the module, as well as software usage 1.1 Intended Audience and Reading Suggestions This document is intended for customers of ReZolt RZ707MS module, usually mounted on RZ707ES-LPS evaluation board. 1.2 Scope of the Document This document describes detailed instructions to measure RF parameters of ReZolt RZ707MS module, mounted on a RZ707ES-LPS evaluation board, including Device driver installation and programming the RZ707ES-LPS board with the firmware for manufacturing test. Setting up the test environment. RF commands to initiate transmission and reception testing procedures, with various RF parameters. ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 2 RZ707MS Overview RZ707MS is member of a family of low power embedded Wi-Fi modules from ReZolt Corporation. It is a component of ReZolt Em-Fi Platform and along with RZ707-ES-LPS Evaluation Board and UbzrvrTM Device & Sensor Management System, offers an end-to-end solution that is easy-to-use, modular, and scalable thereby allowing cost-effective and rapid engineering development for OEM embedded Wi-Fi products. Em-Fi Software provides an option to run customer applications on a host processor on the customer board with simple serial-to-Wi-Fi commands. Em-Fi Software also allows the customer applications to run on an RZ707 Module using the RZ707SDK. 2.1 Energy Monitoring and Management Logistics and Supply Chain Management Healthcare Industrial and Building Automation 2.2 Target Applications Highlights 802.11b/g/n with complete Wi-Fi functionality Low power and best in class networking and other features in easy-to-use, modular, scalable software Rich interfaces allow interfacing with a range of sensors and other peripherals ARM Cortex M3-based microcontroller with processing and memory headroom Supports fine-grained power management for low power operation and long battery life Optional on-module serial Flash facilitates data logging and firmware upgrade 2.3 Features Module Based on Broadcom BCM43362 Wi-Fi and ST Micro STM32F205 Cortex M3 microcontroller Small form factor: 1.24 in X 0.85 in (31.5 mm X 21.6 mm) Rich in interfaces: Up to three UART, three SPI, two I2S, two I2C, one USB, JTAG and GPIOs, ADCs, DACs and timers On-board chip antenna or external antenna using u.FL connector Standby current < 5uA, transmission current < 330 mA, receiving current < 80 mA Worldwide regulatory compliance Wi-Fi Single stream 802.11n support for 20 MHz channel bandwidth provides rates up to 65 Mbps WPA/WPA2 Personal for powerful encryption and authentication AES and TKIP acceleration in hardware for faster data encryption and 802.11i compatibility 802.11d, e(WMM, QoS, WMM-PS), h, i, j, k, r, w; Wi-Fi Protected Setup (WPS) Software ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 Em-Fi Software integrates Wi-Fi and network stack, including UDP, TCP/IP (IPv4), DHCP Client and Server, ARP, DNS, FTP Client, SSL/TLS engine, HTTP/HTTPS Client and Server, and XML parser Run your application code on an external host microcontroller interfacing to RZ707 Module using serial commands Run your application on the on-board STM32F205 Cortex-M3 microcontroller using RZ707 Software Development Kit 2.4 System Architecture RZ707MS Module consists of two main components: STM32F205RE (512KB flash, 128KB SRAM) or STM32F205RG (1MB flash, 128KB SRAM), an ARM Cortex-M3 based 32-bit microcontroller that runs Em-Fi Software and Broadcom BCM43362 Wi-Fi device. It also includes an optional serial Flash (1MB or 2MB), an on-board chip antenna and a u.FL connector for optional external antenna. Voltage Input RZ707 Module supports a flexible power supply. VBATT_WLAN, required for the Wi-Fi device, can be in the range of 2.7V to 4.8V. VBATT_MICRO can be in the range of 1.65V to 3.6V. Vdd, used by the microcontroller and the optional flash, can be in the range of 1.8V to 3.6V. I/O Interface STM32F205RE/RG offers a host of interfaces enabling a rich and flexible hardware design. These include not only the standard interfaces such as UARTs, SPIs, I2C, I2S, GPIOs, ADCs, DACs, and Timers but also USB for easy connectivity for data and provisioning. ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 Radio Frequency BCM43362 Wi-Fi device supports 802.11bgn with the latest Wi-Fi functionality including security and provisioning and enabling a broad range of embedded Wi-Fi products. This module operates within the frequency range between 2412 and 2464 Mhz, which correspond to the central frequency of channel 1 and channel 11 for IEEE 802.11 b/g/n standard. Chip Antenna The chip antenna included on the module (which is also used for FCC test) is manufactured by Johanson, with part number 2450AT42B100E. The datasheet of the antenna is attached to this document. Crystals There are three crystals used on the module. Two crystals connected to STM32F205RG work at 16 Mhz and 32 Khz, respectively. The single crystal connected to BM43362 works at 26 Mhz. STM32F205RG has an internal PLL circuitry, which works at 96 Mhz when it is turned on. Radio Power A piece of software runs on STM32F205RG to control the radio operation. By default, the software always transmits at full power (which is used during test for FCC certificate). ReZolt provides software API to customers in order to lower down the transmission power from the default state, but never beyond the default state. Specifically, following function is provided to customers in order to lower the radio transmission power from the default number: Status wdd_adjust_tx_power(uint8_t pwr), where parameter pwr is in unit of dBm and always capped by the default power number when the software processes this function call. ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 3 Pin Description Alternate Functions Pin Name Function on RZ707ES Board 10 11 12 13 14 GND VBATT_WLAN VBATT_MICRO Alarm output NRST PC0 PC1 PC2 PC3 PA0 PA2 GND VDD PA3 15 16 17 18 PA4* PA5** PA6** PA7** 19 20 21 22 23 24 25 26 27 PB0* PB1 PB10 PB11 GND PB12 PB13 PB14 PB15 28 29 30 31 32 33 34 35 PA8* PA9 PA10 PA11 PA12 GND PA13 PA14 GND VBATT for WLAN VBATT for Micro Alarm output Micro reset GPIO ADC GPIO GPIO WKUP pin ADC GND VDD for Micro ADC NC, used internally as SPI1_NSS for on-module serial flash SPI1_SCK SPI1_MISO SPI1_MOSI NC, used internally for PwrEN of on-module serial flash GPIO USART3_TX USART3_RX GND SPI2_NSS SPI2_SCK SPI2_MISO SPI2_MOSI NC, used internally for Write Protection of onmodule serial flash USB_DET USB_FS_ID USB_FS_DM USB_FS_DP GND JTAG_TMS JTAG_TCK 36 PA15 JTAG_TDI 37 PB3 JTAG_TDO 38 PB4 JTAG_TRST 39 40 41 42 43 44 45 PB5 PB6 PB7 BOOT0 PB8 PB9 GND GPIO USART1_TX USART1_RX BOOT0 switch I2C1_SCL I2C1_SDA GND ReZolt RZ707 Em-Fi Module User Manual UART SPI/I2S GPIO I2C ADC DAC CAN Timer Other GPIO USART2_TX GPIO GPIO GPIO GPIO GPIO GPIO ADC123_IN10 ADC123_IN11 ADC123_IN12 ADC123_IN13 ADC123_IN0 ADC123_IN2 TIM TIM USART2_RX GPIO ADC123_IN3 TIM SPI2_MISO SPI2_MOSI SPI3_NSS / I2S3_WS GPIO GPIO GPIO GPIO ADC12_IN4 ADC12_IN5 ADC12_IN6 ADC12_IN7 GPIO GPIO GPIO GPIO ADC12_IN8 ADC12_IN9 SPI2_SCK / I2S2_CK USART3_CLK I2S2_WS USART3_CTS I2S2_SCK USART3_RTS I2S2_SD GPIO GPIO GPIO GPIO USART1_CLK UART1_TX UART1_RX UART1_CTS UART1_RTS GPIO GPIO GPIO GPIO GPIO I2C2_SCL I2C2_SDA I2C2_SMBA DAC1_OUT DAC2_OUT TIM TIM TIM TIM TIM TIM TIM CAN2_RX TIM CAN2_TX TIM TIM TIM TIM TIM TIM CAN1_RX TIM CAN1_TX TIM RTC_50Hz MCO1 GPIO GPIO SPI1_NSS / SPI3_NSS / I2S3_WS SPI1_SCK / SPI3_SCK / I2S3_CK SPI1_MISO / SPI3_MISO SPI1_MOSI / SPI3_MOSI / I2S3_SD GPIO TIM GPIO TIM GPIO TIM GPIO GPIO GPIO GPIO GPIO SPI2_NSS / I2S2_WS GPIO I2C1_SMBA I2C1 SCL I2C1 SDA CAN2_RX TIM CAN2_TX TIM TIM I2C1_SCL I2C1_SDA CAN1_RX TIM CAN1_TX TIM RZ707MS-UM-081312 4 Electrical Characteristics All the interfaces available on the module are to STM32F205RE/RG microcontroller. Please refer to the STM32F205RE/RG datasheet for further details. 4.1 Absolute Maximum Ratings Min Max Unit Storage Temperature -40 +125 Deg. C Supply Voltage – VBAT_WLAN -0.5 +6 Supply Voltage – VBATT_MICRO -0.3 +4 Supply Voltage – Vdd -0.3 +4 4.2 Operating Conditions Min Typical Max Unit Operating Temperature -30 +25 +85 Deg. C Supply Voltage – VBATT_WLAN 2.7 3.6 4.8 Supply Voltage – VBATT_MICRO 1.8 1.8 or 3.3 3.6 Supply Voltage – Vdd 1.65 1.8 or 3.3 3.6 4.3 Low-Power State Characteristics State Current CPU Clock Registers & SRAM PLL & HSE/HSI** RTC Clock*** RTC SRAM Run* 27 mA ON Retained ON ON Retained Sleep 8 mA OFF Retained ON ON Retained Stop 350 uA OFF Retained OFF ON Retained Standby 6 uA OFF Lost OFF ON Retained * CPU clock running at 90 MHz, executing instructions out of flash, with all peripherals disabled except SDIO and some GPIOs ReZolt RZ707 Em-Fi Module User Manual RZ707MS-UM-081312 ** HSE: External High-Frequency Crystal, 60 uA HSI: Internal High-Frequency RC oscillator, 1 mA PLL: 1.3 mA *** RTC on Internal low frequency oscillator (LSI): 0.4 uA Wake up delay (uS) State Exit Methods CPU HSI* PLL Total Sleep Any interrupt Stop RTC Alarm/Wkup 17 2.2 200 220 Standby RTC Alarm/Wkup 375 2.2 200 577 * If using HSE, its startup time is usually 2 ms after Vdd is stabilized ReZolt RZ707 Em-Fi Module User Manual 10 RZ707MS-UM-081312 5 Installation Guidelines 5.1 Layout Guidelines The module footprint is shown in the above figure. There are two ways of using/connecting antennas ReZolt RZ707 Em-Fi Module User Manual 11 RZ707MS-UM-081312 To use the on-module chip antenna. In this case, the Antenna Area labeled above needs to be kept clear of copper to ensure good RF performance. To use external antenna, via the u.FL coax connector. In this case, it is OK to overlap the Antenna Area with copper. However, to ensure the external antenna meets the requirements of MIC/TELEC, the user needs to contact ReZolt Corporation with detailed specification of the antenna. In addition to the above guidelines, note the following suggestions: 5.2 Place external bypass capacitors as close as possible to the module pins. To achieve better communication quality, keep metallic objects away from the antenna (either the on-module chip antenna or external antennas) as far as possible. Surface Mount Assembly Table below lists recommended reflow parameters. Preheat Ramp up rate from 25 to 150C TBD Soak or dryout Temperature Min (Tsmin) Temperature Max (Tsmax) Time (Ts) from Tsmin to Tsmax TBD TBD TBD Reflow Liquidus Temperature (TL) Time (tL) maintained above TL Peak temperature (Tp) Ramp up rate from TL to Tp Time (tp) within 5C of Tp Ramp up rate from Tp to TL Time 25C to Tp TBD TBD TBD TBD TBD TBD TBD ReZolt RZ707 Em-Fi Module User Manual 12 RZ707MS-UM-081312 6 Limitations THIS DEVICE AND ASSOCIATED SOFTWARE ARE NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE FOR THE OPERATION OF APPLICATION IN A HAZARDOUS ENVIRONMENT, OR REQUIRING FAIL-SAFE PERFORMANCE, OR IN WHICH THE FAILURE OF PRODUCTS COULD LEAD DIRECTLY TO DEATH, PERSONAL INJURY, OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE (COLLECTIVELY, "HIGH RISK APPLICATIONS"). YOU AGREE AND ACKNOWLEDGE THAT YOU HAVE NO LICENSE TO, AND SHALL NOT (AND SHALL NOT ALLOW A THIRD PARTY TO) USE THE TECHNOLOGY IN ANY HIGH RISK APPLICATIONS, AND LICENSOR SPECIFICALLY DISCLAIMS ANY WARRANTY REGARDING, AND ANY LIABILITY ARISING OUT OF, HIGH RISK APPLICATIONS. ReZolt RZ707 Em-Fi Module User Manual 13 RZ707MS-UM-081312 Revision History Date 8/13/2012 Version 0.1 ReZolt RZ707 Em-Fi Module User Manual Changes First draft. 14 RZ707MS-UM-081312
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 14 Language : en-US Tagged PDF : Yes Title : Corporate Backgrounder Author : Gainspan Creator : Microsoft® Office Word 2007 Create Date : 2012:10:11 11:28:12-07:00 Modify Date : 2012:10:11 11:28:12-07:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools