Andon Health 923 Spread Spectrum Transmitter User Manual Ideal BP Manual July07

Andon Health Co., Ltd Spread Spectrum Transmitter Ideal BP Manual July07

Manual

INSTRUCTION MANUALModelPLEASE READBEFORE USEEasy and Affordable Solutionsfor Better Health™M A N A G E M E N T S Y S T E MBlood PressureBP-Manager™*NOTE: The system is intended for information purposes only, for expert advice makesure to consult a healthcare professional. Any instructions for change in treatmentand health related information or advice should only be made directly with ahealthcare professional. The ANDON BP-MANAGER™ is a non-invasiveblood pressure monitor intended for the measurement of systolic (SBP) anddiastolic (DBP) blood pressure and heart rate (HR or pulse rate) using theoscillometric technique. The ANDON BP-MANAGER™ is used as an aidto monitoring blood pressure in adults (individuals aged 18 and older)in a non-clinical environment such as in the home. Results aredisplayed on the ANDON BP-MANAGER™ screen. The ANDONBP-MANAGER™ should not be used on infants or children.Contraindications for Use: The end user of this device should nothave common arrhythmias, such as atrial or ventricularpremature beats or atrial fibrillation.Version 2.0 Jan 2009 *Picture may vary from actual productANDONKD-923
BP-Manager™2Table of ContentsTable of ContentsTABLE OF CONTENTS 2INTRODUCTION 3CONTENTS 4REQUIREMENTS 5!WARNINGS! 6Pod™LOCATION/INTERFERANCE 7BEFORE YOU START 8Your BP-Manager™ 8Your I Pod™ 9INSTALLATION 10Connecting YourPod™ 10Using an RJ11 Jack 10Back-up Batteries 11Powering Up YourBP-Manager™ 11First Time Power Upand Registration 12SUGGESTIONS BEFORE TAKINGA MEASUREMENT 13HOW TO APPLY THE ARM CUFF 13Applying the Pressure Cuff 14HOW TO TAKE A PROPERMEASUREMENT 15FUNCTIONS 16Main Screen 16Taking Your Blood PressureMeasurement 17Error Display 18Looking at PreviouslyTaken Readings 19Looking at Messages 20Looking at Graphics 21Users 22Select User 22Add/Remove User 23CARE AND MAINTENANCE 25SPECIFICATIONS 26BP-Manager™ 26Pod™ 26FCC STATEMENT 27CUSTOMER INFORMATION 28SERVICE REQUIREMENTS 29ANDONANDONANDONANDONANDONANDONANDONANDON
IntroductionInstruction Manual 3IntroductionPlease read this instruction manual thoroughly. For proper interpretationof pressure measurements, make sure to consult a physician.The BP-Manager™ can be used alone to automatically measureyour blood pressure.If you would like to transmit blood pressure information for display on apersonal computer, the optional Pod™ can be purchased.Instructions for Use for the BP-Manager™ and for the Pod™are included in this Instruction manual.**Warning: This system is not recommended for use on infants and is notintended for and should not be used to try to measure the blood pressure ofinfants and children (anyone under the age of 18) as it may not be accurateand/or relied upon.ANDONANDONANDON ANDONThank you for purchasing the ANDON BP-MANAGER™, or KD-923 and ANDON POD™, or ILP0001. This completely automatic system measures your blood pressure and pulse rate, capturessubjective information and manages everything automatically so that you can better manage yourblood pressure with your care provider. Your measurement reading is clearly displayed on a largescreen on the ANDON BP-Manager™ after each measurement, and later stored for a more detailedanalysis in the form of tables for easy viewing and graphs for easy interpretation. Your new ANDONBP-Manager™ uses the oscillometric method of blood pressure measurement, detecting your blood’smovement through your brachial artery and converting the movements into a digital reading. Anoscillometric monitor does not need a stethoscope so the monitor is simple to use.The ANDON KD-923 BP-Manager™ is a non-invasive blood pressure monitor intended for themeasurement of systolic (SBP) and diastolic (DBP) blood pressure and heart rate (HR or pulse rate)using the oscillometric technique. The ANDON BP-Manager™ is used as an aid to monitoringblood pressure in adults (individuals aged 18 and older) in a non-clinical environment such as in thehome. Results are displayed on the ANDON BP-Manager™ screen. The ANDON BP-Manager™should not be used on infants or children. Contraindications for Use: The end user of this deviceshould not have common arrhythmias, such as atrial or ventricular premature beats or atrialfibrillation.
ContentsBP-MANAGER™4X“AA” ALKALINE BATTERIES FOR YOURBP-MANAGER™ILP 0001 POD™(*Anoptional accessory, soldseparately)AC ADAPTER(*Anoptional accessory, soldseparately)TELEPHONE LINE CORD(*Anoptional accessory, soldseparately)ContentsBP-Manager™4SysDiaPul1288564ANDONKD-923ANDONANDONANDONFor Respective Products, make sure your package includes the following items:
RequirementsInstruction Manual 5RequirementsMODULAR JACK REQUIREMENTSADDITIONAL BATTERIESWhen using your ANDON BP-Manager™ with an ANDON Pod™, you willneed an RJ11 type modular jack, which is the most common type of phonejack and might look like the one pictured here. If you don’t have a modularjack, call your local phone company to find out how to get one installed.You may wish to use rechargeable batteries in your ANDON Manager™. The  ANDON Pod™ isequipped to recharge batteries.
!Warnings!!Warnings!BP-Manager™6To assure the correct use of the product basic safety measures should always be followed includingthe precautions listed below:• Read all the information in the instruction manual and any other literature included in the boxbefore using the unit.• Follow the instructions of your healthcare provider.• Contact your physician for specific information about your blood pressure.• Operate the unit only as intended. Do not use for any other purpose.• The ANDON KD-923 BP-Manager™ is a non-invasive blood pressure monitor intended for themeasurement of systolic (SBP) and diastolic (DBP) blood pressure and heart rate (HR or pulserate) using the oscillometric technique. The ANDON BP-Manager™ is used as an aid tomonitoring blood pressure in adults (individuals aged 18 and older) in a non-clinical environmentsuch as in the home. Results are displayed on the ANDON BP-Manager™ screen. The ANDONBP-Manager™ should not be used on infants or children. Contraindications for Use: The enduser of this device should not have common arrhythmias, such as atrial or ventricular prematurebeats or atrial fibrillation.• This system is not recommended for use on infants and is not intended for and should not beused to try to measure the blood pressure of infants and children (anyone under the age of 18) asit may not be accurate and/or relied upon.• Changes or modifications not approved by ANDON INC. may affect the proper functioning ofthis product. No recalibration or verification is needed, as the accuracy of the cuff-pressuretransducers/indicators is valid for the life of the product. The system might not meet itsperformance specifications if stored or used outside the specified temperature and humidityranges detailed below. Do not disassemble or attempt to repair the unit or components. In theevent of malfunction, call ANDON™ directly as instructed below.• Blood pressure measurements determined with this device are equivalent to those obtained by atrained observer using the cuff/stethoscope auscultation method within the limits prescribed bythe American National Standard, Electronic or automated sphygmomanometers. A report ofclinical performance study findings that used the fourth Korotkoff sign to determine overallefficacy are available upon written request with proof of purchase.ANDON
Pod™Note:Pod™ Location/InterferanceInstruction Manual 7ANDONANDONWhen using an ANDON Pod™ to communicate information from your ANDON BP-Manager™,wireless radio waves are used. For maximum distance and interference-free operation, therecommended ANDON Pod™ location is:•     Away from electrical appliances such as a TV, personal computer or a          cordless phone•     In a HIGH and CENTRAL      location with no obstructions      such as wallsWhile using an ANDON Pod™, the telephone line will be in use. If the telephone line is in usebefore using the your ANDON Pod™ and you wish to use the your ANDON Pod™ while thetelephone line is being used, the unit will not be able to make a connection and will store theinformation in your ANDON BP-Manager™ for later transmission.
Before You StartYourBP-Manager™REMEMBER: You can stop the inflationor deflation process anytime by pressingany button.SysDiaPul1288564Before You StartBP-Manager™8DisplayRight “Soft”ButtonLeft “Soft” ButtonSTART/ESCAPEButtonUpper Arm CuffTo assure the correct use of the product basic safety measures should always be followed includingthe precautions listed below:•   Read all information in the instruction manual and any other literature included in the box before    using the unit.•   Follow the instructions of your healthcare provider.•   Contact your physician for specific information about your blood pressure.•   Operate the unit only as intended. Do not use for any other purpose.•   This product is intended for information purposes only. It is not intended for diagnostic purposes    and is not intended and should not be used on infants or children (anyone under the age of 18).•   This is not a clinical device, but a tool for information purposes only.•   Changes or modifications not approved by ANDON INC. may affect the proper functioning of    this product. Do not disassemble or attempt to repair the unit or components.ANDONANDONKD-923
Your Pod™Before You StartInstruction Manual 9Power buttonLED DisplayAC Adapter JackTelephone line cord RJ11Jack For TelephoneConnectionTelephone line cord RJ11Jack For Line ConnectionBattery CoverANDON(*An optional accessory, sold separately)
Installation! FOR YOUR Pod™ !Connecting your Pod™USING AN RJ11 JACKCAUTION!Note: The Pod™ is designed not to draw power from thebatteries when the AC adapter is in use.InstallationBP-Manager™10ANDONANDONANDONANDON•     Unplug phone cord from wall before installing, plugging in an external power source, or changing       batteries.•     Never install telephone wiring during a lightning storm.•     Never touch uninsulated telephone wire or terminals, unless the telephone line has been      disconnected at the network interface.•     Use caution when installing or modifying telephone lines.Plug one end of the telephone line cord (provided) into the jack on the back of your ANDON Pod™marked LINE.Plug the other end of the telephone line cord (provided)into a modular wall jack.If you wish to use the same modular wall jack for yourANDON Pod™ and your telephone, connect the telephoneline cord from your telephone into the jack on the back ofyour ANDON Pod™ marked PHONE.Connect the small end of the power supply into the powerAC jack on the back of the ANDON Pod™ markedPOWER. Plug the other end into an AC power outlet.Your ANDON Pod™ will automatically power up once it isplugged in to an AC power outlet.
USING AN RJ45 JACKRECHARGING BATTERIES WITH YOUR POD™:Powering UpYour BP-Manager™INSTALLING THE BATTERIES (INCLUDED)Note:InstallationInstruction Manual 11Plug one end of the Ethernet cord (not provided) into a modular RJ45wall jack.Plug the other end of the Ethernet cord (not provided) intothe RJ45 jack on the back of your ANDON Pod™.Connect the small end of the power supply into the powerAC jack on the back of the ANDON Pod™ markedPOWER. Plug the other end into an AC power outlet.Your ANDON Pod™ will automatically power up once it isplugged in to an AC power outlet.ANDONANDON•   Remove the battery compartment door on the bottom of your ANDON Pod™ by pushing gently     in the direction shown on the battery cover.•   Place the rechargeable batteries as marked.•   Replace the battery compartment door and push the compartment door shut in the opposite    direction shown on the battery cover.•   When using rechargeable batteries with your ANDON BP-Manager™, simply place them in your    ANDON Pod™ for 10 hours to recharge when battery status is low as indicated on your ANDON       BP-Manager™•    Remove the battery compartment door on your ANDON BP-Manager™ by lifting the battery door     using the notch•    Place the batteries as instructed on the device•    Replace the battery compartment door and click into placeReplacing the battery does not affect previous test results stored in memory of the meter. However,
FIRST TIME POWER UP AND ACTIVATION WHEN USING ANPOD™ (*an optional accessory, sold separately)READ THROUGH THE INC. TERMSAND CONDITIONS FIRST, THEN PROCEEDAND FOLLOW THE PROMPTS ON THESCREEN AS SHOWN HERE:InstallationBP-Manager™12LANGUAGEENGLISHESPANOLFRANCAISOKthe time and date settings may need to be updated if batteries are not in the device for an extendedperiod of time. Use only new batteries of the required size and the recommended type. For bestperformance and the longest life, alkaline batteries are recommended. Do not mix different type, date orbrand name batteries together. Be sure to follow the instructions when installing the batteries. Sincebatteries can leak Chemicals that damages electronic parts, leaving the battery in the housing for a longperiod without using the device may damage the main unit. Please remove the batteries if you are notgoing to use the device for an extended period of time (i.e., 3 months or more). The batteries should bekept away from small children as they pose a choking hazard. If swallowed, promptly see a doctor for help.To use the ANDON BP-Manager™ with your ANDON Pod™ you must call an ANDON customerrepresentative to activate. Make sure to call ANDON before you begin. Then make sure that theANDON Pod™ is connected to a telephone line cord and RJ11 jack, (or an Ethernet cord and RJ45                                                                  jack) and “Powered ON”! Hold down any button on your                                                                  ANDON BP-Manager™ for 3 seconds to Power up.First select the appropriate language using the buttons labeled     and OK.Then Answer the question on the following screen regardingterms and conditions using the YES and NO labeled buttons.To gain full advantage of all the features your ANDON BP-Manager™ has to offer, using an IANDONPod™ is recommended. To ensure that your ANDON BP-Manager™ and v Pod™ are setupproperly you will need to call ANDON directly to activate your system. You should ensure that the stepsare followed correctly, you should first setup your ANDON Pod™, power it up, and then begin the stepsof powering up your ANDON BP-Manager™. During your activation call with ANDON, an ANDONcustomer representative will verify your ANDON BP-Manager™ and  ANDON Pod™ ID numbers. andyou will be ready to take full advantage of all your ANDON BP-Manager™ has to offer. For a detaileddescription of all the features and functions continue to the FUNCTIONS section of this manual.ANDONANDONANDON
Suggestions Before Taking AMeasurement•Avoid eating, smoking, and exercising for 30 minutes before taking a measurement. Rest at least15 minutes before taking a measurement.•Stress raises blood pressure. Avoid taking measurements during stressful times.•Remove tight-fitting clothing from your left arm.•Measurements should be taken in a quiet place.•Sit in a chair with your feet flat on the floor. Rest your left arm on a table so that the cuff is atthe same level as your heart.•Remain still and do not speak during the measurement.•It is recommended that a record of your blood pressure and pulse readings be brought to yourphysician on a regular basis, as a single measurement does not provide an accurate indication ofyour true blood pressure.•It is recommended that you take and record several readings over a period of time, measuringyour blood pressure at the same time each day for consistency.•If you are taking multiple readings consecutively, you should wait 2-3 minutes betweenmeasurements. The wait time allows the arteries to return to the condition prior to taking theblood pressure measurement. You may need to increase the wait time depending on yourindividual physical characteristics.CAUTION: Blood pressure recording can be affected by the position of thesubject, his/her physiologic condition, and other factors.Suggestions Before Taking A MeasurementInstruction Manual 13Ideal BP Manual Jan09:Ideal BP Manual July07  12/21/10  2:06 PM  Page 13
How To Apply The Arm CuffApplying the Pressure CuffSTEP 1STEP 2STEP 3STEP 4STEP 5STEP 6How To Apply The Arm CuffBP-Manager™14.(Your ANDON BP-Manager™ applies the Oscillometric method to measure human systolic/diastolicblood pressure and heart rate. All values are shown on the LCD monitor.Connect the Air Plug to the Air Jack at the side ofthe monitor.Assemble the cuff as shown in the figure. Thesmooth cloth is on the inside of the cuff loop.Hold your left arm in front of you with your palm facing up. Pull your arm through the cuff loop.The edge of the cuff should be approximately0.3 to 1.2 inches (2cm to 3cm) above yourelbow. Align the tubing over the main arteries onthe inside of your arm.When the cuff is positioned correctly, pull the end of the cuff to tighten the cuff snugly around yourupper arm. You should be able to fit your index finger between the cuff and your arm.Press the hook material firmly against the pile material. The top and bottom edges of the cuff shouldbe tightened evenly around your arm.ANDONPile Sided MaterialSewn Hook MaterialD-Ring0.3 to 1.2 inches  (2cm to 3cm) Main Arteries
How To Take A ProperMeasurementPlease sit or lie down for at least 5-10 minues before measuring. Perform measurement while sitting.STEP 1Place your elbow on a table or other object. Relaxyour hand with he palm facing up.STEP 2Make sure the pressure cuff is at the same levelas your heart. This is extremely important for theaccuracy of the results. Higher or lower positions will give deviations from the true value.How To Apply The Arm CuffInstruction Manual 15Ideal BP Manual Jan09:Ideal BP Manual July07  12/21/10  2:06 PM  Page 15
Functions(when using the POD™,an optional accessory sold separately)Main ScreenFunctionsBP-Manager™16MENUANDONANDONThe Main Screen is your default screen. This is where youwill be directed to after completing functions and whereyou will find status indicators for the functioning of yourANDON BP-Manager™.In the upper middle portion of the display you will find abattery icon, displaying power status of your ANDONBP-Manager™Indicates full powerIndicates power is getting low, you should change your batteriesIndicates that your blood pressure measuring function has been turned off.Replace your batteries immediately.If you have unread messages, you will see an envelope icon on the upper left corner of the display.ANDON
Taking Your Blood Pressure MeasurementSTEP 1STEP 2" "! You can stop the inflation/deflation at any time by pressing any button onyour BP-Manager™ !FunctionsInstruction Manual 17IPlease sit or lie down for at least 5-10 minues before measuring. Perform measurement while sitting.Place your elbow on a table or other object. Relaxyour hand with he palm facing up.Make sure the pressure cuff is at the same levelas your heart. This is extremely important for theaccuracy of the results. Higher or lower positions will give deviations from the true value.From the default screen, press the button located in the center of the key pad to continue.A graphic will appear to show the correct placement of the cuffon the arm.                                           Your ANDON BP-Manager™ will begin to inflate automatically.                                           Do not talk or move during the measurement.                                           The cuff will quickly inflate to the appropriate level and will                                           get tighter around your arm. If the cuff becomes too tight, pressany button to stop the unit from inflating and then re-wrap the cuff, leaving a little more roombetween the cuff and your arm.When the measurement is complete, the cuff will automatically deflate releasing the cuff’s airpressure. Your ANDON BP-Manager™ will then display your reading automatically, and begin tocommunicate when you are using your ANDON Pod™. Your ANDON BP-Manager™ will notify youon the bottom of the display as to the status of your connection. Connection times may varydepending on many factors. Your reading will always be stored in your meter memory for local lookup.After displaying your reading and automatically communicating the information, your meter willautomatically return to the default screen before going to sleep mode. Each time your ANDONBP-Manager™ communicates successfully to ANDON through your ANDON Pod™ the time anddate are set to ensure reliable date and time stamping of all readings.ANDON
ERROR DISPLAYNOTE: If you receive an error, wait 2-3 minutes and retake yourmeasurement. If you still receive an error, wait for the unit to go into sleepmode, then try again and retake your measurement. If you continuallyreceive the same error after repeated usage, call an customerrepresentative at: 1-888-IDEAL-41 ( ) .FunctionsBP-Manager™18An error will be displayed for the following:• Noise, movement or talking during a measurement.• Inadequate pressure for cuff inflation due to movement or talking during measurement.• Cuff improperly applied (too tight, too loose, improper position).• Other factors may also cause an error to display.ANDONANDON86-22-60526081
LOOKING AT PREVIOUSLY TAKEN READINGSFunctionsInstruction Manual 19MENUREADINGSMESSAGESGRAPHICSUSERSSCROLL SELECTDATE SYS DIA PUL0210 120 82 710209 122 84 700208 118 84 700208 120 82 710207 118 82 73NEXTDATE SYS DIA PUL0206 120 85 700205 122 84 700204 121 83 720203 123 85 750202 120 82 71BACK NEXTYour ANDON BP-Manager™ will store up to 575 of your latest readings.Press Menu to view the feature list.SCROLL to highlight READINGS (it should already behighlighted as it is the first line item in the list).Press SELECT to enter your selection.You can now scroll through your readings, screen by screenusing the NEXT (and BACK) buttons.If you have less than one page full of readings or havereached your final screen you can press the button labeledEXIT to return to the MENU section (Remember you canalways press the START/ESCAPE button to return to thedefault screen).
Looking at MessagesForExample:FunctionsBP-Manager™20f: DAUGHTERs: DINNERWhen do youwant to goto dinner?NEXTs: DINNER7:00 PM7:30 PM8:00 PM9:00 PMSCROLL SELECTf: SELFs: KIDSReminder:Pick up kidsat 4:00 PM.OKMENUREADINGSMESSAGESGRAPHICSUSERSSCROLL SELECTYour ANDAN BP-Manager™ is equipped for 2-way, interactive communication when using an ANDANPod™. Messages can be sent remotely to your ANDAN BP-Manager™ and responded to directly. Whenmessages are transmitted to your ANDAN BP-Manager™, they are stored for automatic display beforeyour next blood glucose measurement. If you have unread messages in memory, there will be anENVELOPE icon located on the upper left corner of the default screen. You can also read any unreadmessages in the MESSAGES section for later response.• Press Menu to view the feature list.• SCROLL to highlight MESSAGES.• Press SELECT to enter your selection.Messages will be displayed in order of time received(oldest first). Responding to messages automatically storesthem for later transmission and automatically scrolls to thenext message if there is more than one unread message inyour ANDAN BP-Manager™.      There are 2 types of messages. The type of question will dictate the button labels. Simply pressthe desired button shown on the screen.Free text messages allow for 2 possible responses, and aredisplayed on one screen and may look like this:Multiple Choice messages allowing for up to 6 possible responses are displayed on 2 screens, andmay look like this:ANDON
Looking at GraphicsFunctionsInstruction Manual 21MENUREADINGSMESSAGESGRAPHICSUSERSSCROLL SELECTBACK EXITLATEST SYS/DIA1801501209060 09 JAN–09 JANBACK NEXTWhen using an ANDON Pod™, your ANDON   BP-Manager™ will store different types of graphicsdownloaded from the ANDON website. (All the graphics can be altered through the ANDONwebsite, refer to www.ideallifeonline.com for details).Press Menu to view the feature list.• SCROLL to highlight GRAPHICS.• Press SELECT to enter your selection.• You can now scroll through your graphics screen by screenusing the button labeled NEXT. While scrolling through screens,you can always go to the previous screen by pressing the buttonlabeled BACK.If you have only one graphic in memory, or have reachedyour final screen you can press the button labeled EXIT toreturn to the MENU section (Remember you can alwayspress the START/ESCAPE button to return to the defaultscreen).
UsersSELECT USERFunctionsBP-Manager™22MENUREADINGSMESSAGESGRAPHICSUSERSSCROLL SELECTUSERSSELECT USERADD/REMOVE USERSCROLL SELECTSELECT USERUSER 1USER 2SCROLL SELECTThe USERS section allows you to set-up your ANDON BP-Manager™ with an option to allow 2 usersto use the same device.v• Press Menu to view the feature list.• SCROLL to highlight USERS• Press SELECT to enter your selection.Using the Scroll and SELECT buttons, select the SELECT USERoption. When more than one user is setup in the device, theSELECT USER function allows an individual to switch thecurrent user selected in the device. When selecting SELECTUSER, if only one user is selected in the device it will displaythe current user in the device. If there are multiple users insetup in the device, using the SCROLL and SELECT buttons auser can switch between USER 1 and USER 2Selecting USER 1 will set the device to USER 1. SelectingUSER 2 will set the device to USER 2.ANDON
ADD/REMOVE USER•Press Menu to view the feature list.•SCROLL to highlight USERS•Press SELECT to enter your selection.•Press SCROLL to highlight ADD/REMOVE USER.•Press SELECT to enter your selection.When there is only one user setup in the device, the ADD USER function will be initiated.Press the YES button to add an additional user in thedevice. The next screen will walk the new user through theuser setup process. Press the NO button to exit the ADDUSER function and return the user to the main USERSoptions screen.When there are two users setup in the device, the REMOVE USER function will be initiated.FunctionsInstruction Manual 23MENUREADINGSMESSAGESGRAPHICSUSERSSCROLL SELECTUSERSSELECT USERADD/REMOVE USERSCROLL SELECTADD USER?NO YESIdeal BP Manual Jan09:Ideal BP Manual July07  12/21/10  2:06 PM  Page 23
rtFunctionsBP-Manager™24REMOVE USERREMOVE USER 1REMOVE USER 2EXITSCROLL SELECTREMOVE USER 2NO YESUsing the SCROLL and SELECT buttons, a user can beremoved from the device. Selecting EXIT will take the user tothe USER options screen. When selecting a particular USER,as for example REMOVE USER 2 (as shown in the examplebelow), that particular use will be displayed requiring aconfirmation to remove from the device.Pressing NO will return the user to the USER options screen.SELECTING YES will display an hour glass while the deviceremoves the selected USER from the device. When complete,the device will return to the default screen.1ANDON
Care and MaintenanceCare and Maintenance25Instruction ManualTo maintain your ANDON BP-Manager™ in the best condition, and protect the unit from damage,you should follow the directions listed below.• Clean the monitor with a soft dry cloth. You may also use an alcohol swab to wipethe cuff and meter clean. Do not use any abrasive or volatile cleaners. Never immerse the unit orany components in water.• Store the ANDON BP-Manager™ in a safe and dry location. Do notfold the cuff and tubing tightly. Do not subject the monitor to extreme hot or cold temperatures,humidity and direct sunlight.• Avoid subjecting the ANDON BP-Manager™ to strong shocks, suchas dropping the unit on the floor.• Remove the batteries if the unit will not be used for three months or longer. Alwaysreplace the batteries with new ones at the same time.• Use the ANDON BP-Manager™ consistent with instructionsprovided in this manual. Use only authorized parts and accessories.
SpecificationsBP-Manager™SpecificationsBP-Manager™26ANDONANDONModel:                                                       BPM 0001 ANDON BP-Manager™Display:                                                     LCD Digital DisplayMeasurement Range:                               Pressure: 30-280 mmHg, Pulse: 40-180 Pulses per minuteAccuracy / Calibration:                             Pressure: +/- 3 mmHg, Pulse: +/- 5%Inflation:                                                   Automatic by electronic pumpDeflation:                                                  Linear ValveRapid Air Release:                                   Linear ValvePressure Detections:                               Pressure transducerMeasurement Method:                             Oscillometric methodPulse Wave Detections:                           By peaks of waveformPower Source:                                          4 “AA” alkaline batteriesBattery Life:                                              battery life is approx. 3 months depending on usageOperating Temperature/Humidity:            50°F to 104°F (5°C to 40°C)/Below 90% relative humidityMeter Storage Temperature/Humidity      -4°F to 140°F (-20°C to 55°C)/Below 95% relative humidityConsole Weight:                                       Approx. 290g without batteriesOuter Dimensions:                                   Approx. 110 mm Width x 130 mm Depth x 78 mm HeightCuff Dimensions:                                      Cuff circumference: 22-30cmNote: these specifications, to improve performance, are subject to change without notice.(*An optional accessory, sold separately)Model:                                                     ILP 0001 ANDON Pod™Display:                                                   3 LED’sPower Source:                                         AC adapterOperating Temperature/Humidity:           50°F to 104°F (10°C to 40°C)/Below 85% relative humidityStorage Temperature/Humidity               23°F to 122°F (-5°C to 50°C)/Below 90% relative humidityConsole Weight:                                      Approx. 142 g without batteriesOuter Dimensions:                                   Approx. 120 mm Width x 105 mm Depth x 30 mm HeightNote: These specifications are subject to change without notice.
FCC StatementFederal Communications Commission(FCC) StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions:1) this device may not cause harmful interference, and2) this device must accept any interference received, including interference that may causeundesired operation of the device.You are cautioned that changes or modifications not expressly approved by the part responsible forcompliance could void the user’s authority to operate the equipment.This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protectionagainst harmful interference in a residential installation. This equipment generates, uses and canradiate radio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee that interferencewill not occur in a particular installation. If this equipment does cause harmful interference to radioor television reception, which can be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of the following measures:•Reorient or relocate the receiving antenna.•Increase the separation between the equipment and receiver.•Connect the equipment into an outlet on a circuit different from that to which the receiver isconnected.•Consult the dealer or an experienced radio/TV technician for help.FCC RF Radiation Exposure Statement:This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.End users must follow the specific operating instructions for satisfying RF exposure compliance. Thistransmitter must not be co-located or operating in conjunction with any other antenna or transmitter.FCC StatementInstruction Manual 27Ideal BP Manual Jan09:Ideal BP Manual July07  12/21/10  2:06 PM  Page 27
Service RequirementsService RequirementsInstruction Manual 2In the event of equipment malfunction, all repairs should be performed by our Company or anauthorized agent. It is the responsibility of users requiring service to report the need for service toour Company or to one of our authorized agents. Please refer to the location you purchased orreceived your equipment for details of where service can be facilitated through.8