Andrew Wireless Innovations Group RPT-MOR801 Cellular Repeater with Optical Interface User Manual Users manual
Andrew Wireless Innovations Group Cellular Repeater with Optical Interface Users manual
Users manual
User’s manual for Remote Unit MOR801B Power User’s manual for band or channel selective Remote Unit MOR801B Power (Id.-No. 147359) Author: M0070A0A.doc Approved: Id.-No 151155 QA: Page 1 18-June-99 User’s manual for Remote Unit MOR801B Power Table of Contents LIST OF UNIT SPECIFIC ABBREVIATIONS CONTENTS OF DELIVERY HEALTH AND SAFETY WARNING 10 PREAMBLE 11 13 INTRODUCTION 1.1 Intended purpose 13 1.2 About the MOR801B POWER 13 FUNCTIONAL DESCRIPTION 14 2.1 General 15 2.2 RF modules 15 2.3 Mother board 17 2.4 Control module SM 2009 18 2.5 Duplexer 19 2.6 Active Combiner 20 2.7 Transceiver MFY1309 20 2.8 FSK modulator 21 2.9 4-way-Splitter 22 2.10 Measuring aids 22 2.11 Power supply 22 2.12 Feed forward amplifier 24 M0070A0A.doc Id.-No 151155 Page 2 18-June-99 User’s manual for Remote Unit MOR801B Power FUNCTIONS AND FEATURES 25 3.1 Band and channel selectivity 25 3.2 Gain setting 25 3.3 ALC 26 3.4 BITE and alarms 3.4.1 Handling of alarms 3.4.2 Status report 3.4.3 Severity levels 26 28 29 30 32 OPTIONAL EQUIPMENT 4.1 VSWR module 32 4.2 External alarms 32 4.3 Battery backup module 34 SPECIFICATION 36 5.1 Electrical specification 36 5.2 Optical specification 38 5.3 Mechanical specification 38 5.4 Environmental and safety 38 5.5 External electrical interfaces 5.5.1 Electrical power 5.5.2 RF connection 5.5.3 Optical connector 39 39 40 40 41 6.1 INSTALLATION Mechanical installation 42 6.2 Electrical installation 6.2.1 Grounding 6.2.2 Power connection 6.2.3 Connection of the antenna cable 6.2.4 Connecting fibre optic cables M0070A0A.doc Id.-No 151155 45 45 46 46 47 Page 3 18-June-99 User’s manual for Remote Unit MOR801B Power SETTING TO WORK 7.1 49 Preparation 49 7.2 Setting of operational parameters 7.2.1 Manual setting of the attenuation by means of rotary switches 7.2.2 Settings via personal computer as terminal 7.2.3 Remote control via Master Unit 50 50 52 54 TROUBLE SHOOTING 55 8.1 Error indication 55 8.2 Boot process 55 8.3 Alarm monitoring with the STATUS HIST command 56 8.4 Power supply 56 8.5 General remarks 56 MAINTENANCE 57 9.1 General 57 9.2 Replacement of the fuses (mains) 57 9.3 Replacement of the power supply fuse 58 9.4 Replacement of the mains cable 58 9.5 Replacement of the RAM / RTC battery 59 9.6 Replacement of the dummy battery backup module 60 9.7 Replacement of the duplexer 61 9.8 Replacement of RF modules 62 9.9 Replacement of the control module SM 2009 64 9.10 Replacement of power supplies 65 9.11 Replacement of Active Combiner modules 66 9.12 Replacement of feed forward amplifier 67 9.13 Replacement of the FSK modulator 69 M0070A0A.doc Id.-No 151155 Page 4 18-June-99 User’s manual for Remote Unit MOR801B Power 9.14 Replacement of the Transceiver MFY1309 69 10 SPARE PARTS LIST 70 11 CONFIGURATION LIST 72 12 APPENDIX 73 12.1 Installation drawing of the Repeater 73 12.2 Top view of the Repeater (left-hand side , four channel configuration) 74 12.3 Top view of the Repeater (right-hand side, four channel configuration) 75 12.4 One channel configuration –block diagram and cabling 76 13 INDEX M0070A0A.doc 78 Id.-No 151155 Page 5 18-June-99 User’s manual for Remote Unit MOR801B Power LIST OF FIGURES AND TABLES table 1-1 List of international sales offices............................................................................. 12 figure 2-1 Block diagram of MOR801B Power...................................................................... 14 figure 2-2 Top view of an RF module .................................................................................... 16 figure 2-3 Top view of a mother board .................................................................................. 17 figure 2-4 Top view of the control module............................................................................. 18 figure 2-5 Top view of the duplexer....................................................................................... 19 figure 2-6 Top view of an Active Combiner module.............................................................. 20 figure 2-7 Transceiver MFY1309 .......................................................................................... 20 figure 2-8 Installation position of the Transceiver.................................................................. 21 figure 2-9 Configuration of the connecting pins..................................................................... 21 figure 2-10 Top view of the 4-way-Splitter (Transceiver dismounted) .................................. 22 figure 2-11 Mounting position of power supplies .................................................................. 23 figure 2-12 ON / OFF position of external switch.................................................................. 24 figure 2-13 Top view of the feed forward amplifier............................................................... 24 figure 3-1 Position of rotary switches .................................................................................... 25 figure 3-2 Position of failure LEDs ........................................................................................ 26 figure 3-3 Status hist report.................................................................................................... 27 table 3-4 List of all available alarms ...................................................................................... 28 figure 3-5 Example of a GET1 report..................................................................................... 29 figure 3-6 Example of a STATUS report ............................................................................... 30 figure 4-1 Clamps for external alarms.................................................................................... 32 figure 4-2 Cable configuration and installation position ........................................................ 34 figure 4-3 Mounting position of batteries............................................................................... 35 figure 5-1 Screw terminal for mains cable ............................................................................. 39 figure 5-2 Connector panel layout.......................................................................................... 40 figure 6-1 System description ................................................................................................ 41 figure 6-2 Wall mounting brackets......................................................................................... 43 figure 6-3 Clearance distance................................................................................................. 44 figure 6-4 Grounding kit ........................................................................................................ 45 figure 6-5 Screw terminal ...................................................................................................... 46 table 7-1 LED indication........................................................................................................ 49 figure 7-2 Position of the DIP-Switch 1 ................................................................................. 50 figure 7-3 Position of the rotary switches............................................................................... 51 figure 7-4 Rotary switches and label...................................................................................... 51 table 7-5 DIP-switch configuration ........................................................................................ 52 figure 7-6 DIP-switch 2 for local mode.................................................................................. 52 figure 9-1 Top view of the Repeater ...................................................................................... 57 figure 9-2 Fuse terminal......................................................................................................... 58 figure 9-3 Position of power supply fuse................................................................................ 58 figure 9-4 Position of RAM/RTC battery.............................................................................. 60 figure 9-5 Position of dummy battery backup module ........................................................... 61 figure 9-6 Cable configuration of the duplexers..................................................................... 61 figure 9-7 Connector panel layout.......................................................................................... 62 figure 9-8 Top view of an RF module .................................................................................... 63 M0070A0A.doc Id.-No 151155 Page 6 18-June-99 User’s manual for Remote Unit MOR801B Power figure 9-9 Position of hex coded rotary switches ................................................................... 64 table 9-10 Address of synthesizer .......................................................................................... 64 figure 9-11 Position of control module .................................................................................. 65 figure 9-12 Power supply....................................................................................................... 65 figure 9-13 Position of special-nut M4................................................................................... 66 figure 9-14 Position of counter sunk screws on Active Combiner ......................................... 67 figure 9-15 Position of the feed forward amplifier reset board............................................... 68 figure 9-16 Position of feed forward amplifier (Right-hand side of Repeater) ....................... 68 figure 9-17 FSK modulator .................................................................................................... 69 figure 9-18 Installation position ............................................................................................. 69 table 10-1 Spare parts list....................................................................................................... 71 figure 11-1 Sample of a configuration list.............................................................................. 72 figure 12-1 Installation drawing of the Repeater .................................................................... 73 figure 12-2 Top view of the Repeater (left-hand side, four channel configuration)................ 74 figure 12-3 Top view of the Repeater (right-hand side, four channel configuration) ............. 75 figure 12-4 Block diagram of one channel Repeater .............................................................. 76 figure 12-5 Cabling of one channel Repeater ......................................................................... 77 M0070A0A.doc Id.-No 151155 Page 7 18-June-99 User’s manual for Remote Unit MOR801B Power LIST OF UNIT SPECIFIC ABBREVIATIONS ALC BCCH BITE BTS DL ETS FFwd FSK Id.-No. I²C-Bus LMT MFY MOR OMC PABX PCMCIA PSTN Rev RF RLP RSSI RTC SDA SCL UL UPS VSWR M0070A0A.doc Automatic Level Control Broadcast Control Channel Built In Test Equipment Base Transceiver Station Downlink European Telecommunication Standard Feed Forward Amplifier Frequency Shift Keying Ident Number Inter Integrated Circuit Bus ( Philips ) Local Maintenance Timeout MIKOM Transceiver MIKOM Optical Repeater Operation and Maintenance Centre Private Automatic Branch Exchange Personal Computer Modem Communication International Association Public Switched Telephone Network Revision Radio Frequency Radio Link Protocol Receive Signal Strength Indication Real Time Clock Serial Data Line of I²C-Bus Serial Clock Line of I²C-Bus Uplink Uninterruptable Power Supply Voltage Standing Wave Ratio Id.-No 151155 Page 8 18-June-99 User’s manual for Remote Unit MOR801B Power CONTENTS OF DELIVERY Qty Repeater MOR801B Power Qty User’s manual for Repeater MOR801B Power Qty Set of test protocols consisting of an electrical acceptance test protocol and a safety test protocol applying to the power supply Qty Spare parts kit containing: - 1 control cable RS232, - 1 hex socket key, size 2.5 - 1 Torx key - 5 socket head cap screws M3.0 x 30 - 2 tallow-drop screws TRX M5.0x25 - 2 tallow-drop screws M2.0x6 - 2 tallow-drop screws M3.0x5 - 4 straight pins 3.0 x 25 - 3 captive washers for M5 - 4 Tyraps - 3x5g Silicon heat conducting paste - 1 hex socket screw key , size 4, long - 4 nuts - 2 fuses 8 A type MT - 5 socket head cap screws M3.0x20 - 2 countersunk head screw M3.0x20 - 4 special nuts M4 Qty Wall mounting kit - 2 mounting brackets - 4 washers for M8 - 4 socket head cap screws M8.0x16 - 2 tire bolts Qty M0070A0A.doc Wall mounting sheet Id.-No 151155 Page 9 18-June-99 User’s manual for Remote Unit MOR801B Power HEALTH AND SAFETY WARNINGS Note: Note: Note: Note: Note: Note: M0070A0A.doc The electrical installation has to be performed in accordance with the safety regulations of the local authorities. Due to safety reasons the electrical installation must be performed by qualified personnel. The cover of this unit should not be opened while power is applied. Subsequent installation, commissioning and maintenance activities that require the unit to be powered with the cover open shall only be carried out by suitably qualified personnel. The grounding of the Unit has to be performed by all means. A grounding bolt is provided at the cabinet in order to connect the earth bonding cable. The Unit is heavy-weight. Make sure that a suitable mounting surface is used. Only adequate manpower is allowed to handle the system. ESD precautions have to be observed! Before maintenance work use the available grounding system to connect ESD protection measures. Due to power dissipation the Repeater may heat up the air volume inside the cabinet and reach a very high temperature. Therefore the Repeater must be mounted in the vertical plane to a wall or a mast without additional enclosure to provide sufficient ventilation. Between the housing and the wall a minimum distance must be kept in order to provide air circulation. Laser radiation! Do not stare into the beam or view directly with optical instruments. Class 3A laser product. Id.-No 151155 Page 10 18-June-99 User’s manual for Remote Unit MOR801B Power PREAMBLE In cellular systems, Repeaters are used to enhance the influence of a base station in regions where, due to topological conditions, poor field strengths disable communication. MIKOM is a leading manufacturer of Repeaters. They provide excellent electrical characteristics, they are light-weight and easy to install. Hence, the MIKOM Repeater is the preferred solution. Your Repeater has been built using high reliable materials. A comprehensive quality assurance has been applied to all fabrication steps. This secures constant quality of the product. Every Repeater leaves the factory only after a thorough final acceptance test, accompanied by a test certificate, which warrants perfect function. The acceptance test certificate is subject of the delivery, and it is fixed to the Repeater lid in order to provide a quick reference for the user. Any intervention has to be performed by authorized persons only. If you need technical assistance with the Repeater MOR801B Power approach your local sales office ( see table 1-1 List of international sales offices ) or MIKOM directly at the following address: MIKOM GmbH Industriering 10 86675 Buchdorf Germany Tel: +49 (0) 9099 6 90 Fax: +49 (0) 9099 69 31 email: sales@mikom.com http://www.mikom.com Under consideration of all references given in this manual, the Repeater should be taken into service without any complications and should operate trouble-free for a long time. M0070A0A.doc Id.-No 151155 Page 11 18-June-99 User’s manual for Remote Unit MOR801B Power LIST OF INTERNATIONAL SALES OFFICES Allen Telecom Allen Telecom ( Australia ) Forem France P/L 30500 Bruce Industrial Parkway PO Box 903 Z.I. des Ebisoires Cleveland, Ohio 44 139-3996 Bankstown NSW 2200 78370 Plaisir USA Australia France Phone: +1 ( 216 ) 349-8657 FAX: +1 ( 216 ) 349-8408 Phone: +61 ( 2 ) 9793-9644 FAX: +61 ( 2 ) 9793-9747 Phone: +33-1-30-79-15-30 FAX: +33-1-30-55-55-37 FOREM S.p.A. AT Singapore AT China Via Archimede N. 22/24 20041, Agrate Brianza Milan Italy 80 Marine Parade Road #19-1 Parkway Parade Singapore 449269 CITIC Building, # 11-05 19 Jiangguomenwai Avenue Beijing China 100004 Phone: +39-39-605-41 FAX: +39-39-605-4477 Phone: +65-345-8022 FAX: +65-345-8033 Phone: +86-10-6508-3088 FAX: +86-10-6508-3066 AT Canada FOREM UK AT Hong Kong 1815 Ironstone Manor, # 12 Pickering, Ontario L1W 3W9 Canada Unit D Castle Industrial Park Pear Tree Lane Newbury, Berkshire U.K. RG 14 2EZ 1603 Remington Certer, 23 Hung to road, Kwun Tong, Kow Loon Hong Kong Phone: +1 ( 905 ) 839-3474 FAX: +1 ( 905 ) 839-4663 Phone: +44-1635-569-695 FAX: +44-1635-569-463 Phone: +852-2389-1844 FAX: +852-2389-4864 AT India B-256 Ground Floor. Chittaranjan Park New Delhi 110019 Phone: +91-11-696-3918 FAX: +91-11-652-1648 table 1-1 List of international sales offices M0070A0A.doc Id.-No 151155 Page 12 18-June-99 User’s manual for Remote Unit MOR801B Power 1 Introduction 1.1 Intended purpose Cellular telephone systems transmit signals in two directions between base stations and mobile telephones within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, a Repeater is used to extend transmission range. In the downlink path the Repeater picks up the signal from a donor antenna of an existing cell, amplifies and re-transmits it into the desired dark spot. In the uplink direction the Repeater receives signals from mobile stations present in its coverage area and re-transmits them to the corresponding base station. 1.2 About the MOR801B POWER MIKOM’s MOR801B Power Remote is available as a band or channel selective optical repeater for Analog, CDMA, and TDMA technology. The MOR801B Power Remote repeater bi-directionally amplifies signals between multiple mobiles and a single base station in the AMPS800 frequency band using optical fibres for interconnection to a Master Unit. It is employed mainly in tunnels, canyons, and other areas, where physical structures cause weak field strengths. It can provide highly selective amplification of band segments or channels in the AMPS800 band. The MOR801B Power Remote can be combined with other repeaters in order to create a multi-band optical repeater system. Modules operating in PCS1900, GSM1800, GSM900, or iDEN bands are available. When different modules are combined a common antenna and control interface is available. The MR801 Power Remote can be set-up locally at the Master Unit through the optical fibre or remotely at the OMC. A PCMCIA slot for modem operation is an available option at the Master Unit. The repeater has a large number of functions that can be monitored and changed by the operators via a terminal emulation program or the MIKOM OMC software platform. An easy to understand and simple to learn communication language is available to help the operator query status reports from the repeater or to change settings. M0070A0A.doc Id.-No 151155 Page 13 18-June-99 User’s manual for Remote Unit MOR801B Power 2 Functional description The Repeater MOR801B Power can be equipped from one to four bands or channels. The following block diagram shall illustrate the configuration of the system. *: one physical module contains UL and DL **: with more than two channels, the amplifier is included *** For correct cabling see Assembly Guide figure 2-1 Block diagram of MOR801B Power M0070A0A.doc Id.-No 151155 Page 14 18-June-99 User’s manual for Remote Unit MOR801B Power 2.1 General The Repeater consists of two amplifier chains. The signals to and from the mobiles are combined to an antenna by a frequency separation unit, denominated in the following as Duplexer. The optical signals to and from the Master Unit are converted by the Optical Transceiver. In the Downlink direction the optical signals from the Master Unit are converted into RFsignals by the Transceiver (see chapter 2.7). They pass the 4-way-Splitter (see chapter2.9), which provides the RF-signal for the RF modules. After the RF module (see chapter 2.2) they are combined by the Active Combiner (see chapter 2.6) and afterwards amplified by the Feed Forward Amplifier (see chapter 2.12), which provides the required output power. Finally the signals are fed to the antenna by the Duplexer (see chapter 2.5). In the Uplink direction the signals from the mobiles are seperated by the Duplexer, get to a Pre-Amplifier and afterwards to an RF module. The signals are combined by the Active Combiner then, get converted into optical signals by the Transceiver (see chapter 2.7) and are finally transmitted to the Master Unit. In the final amplifier of the Downlink a power detection measures the output power and controls the gain. In the Uplink the gain is controlled by the Active Combiner to protect the Optical Transceiver. This power detection is called Automatic Level Control (ALC) (see chapter 3.3). 2.2 RF modules The task of the RF modules is to amplify the receive signals and to convert them into an intermediate frequency. The signals, then, proceed a filter stage comprising of highly selective filters, and run through a digital controllable attenuator. The attenuation can be set in steps of 2 dB, locally or remotely. By using the same synthesizer frequency, that was used to convert the signals down to intermediate frequency, the intermediate frequency is mixed up to the original frequency. The synthesizer is controlled via an I²C-Bus. In case of a breakdown in mains, gain and frequency data are non-volatile stored in an EEPROM on board. See figure 2-2 Top view of an RF module for an exemplary channel or band module. M0070A0A.doc Id.-No 151155 Page 15 18-June-99 User’s manual for Remote Unit MOR801B Power figure 2-2 Top view of an RF module M0070A0A.doc Id.-No 151155 Page 16 18-June-99 User’s manual for Remote Unit MOR801B Power 2.3 Mother board The function of the mother board is the communication between the RF modules and the control module via the I²C-Bus. In the three and four channel configuration of the Repeater there is a mother board on the leftand on the right-hand side, whereas in the one and two channel configuration there is only one mother board implemented on the right-hand side of the Repeater. Mother boards are located underneath the RF modules. figure 2-3 Top view of a mother board M0070A0A.doc Id.-No 151155 Page 17 18-June-99 User’s manual for Remote Unit MOR801B Power 2.4 Control module SM 2009 The control module SM 2009 is a DOS compatible micro computer. The whole communication between the operator and the Repeater can be done via the control module. By using the RS232 interface the Repeater can be controlled locally by using a VT100 terminal, or a PC emulating the VT100 terminal. Frequency and gain, power down of RF stages and ALC can be controlled and status messages can be received remotely via the Master Unit. The data transfer between the control module SM 2009 and the mother board is realized by the I²C-Bus system. The I²C-Bus concept was developed by Philips for the serial connection of integrated circuits within one device. Two wires, SDA - serial data and SCL - serial clock, carry data between the devices connected to the bus. Each device is recognized by a unique address and can operate either as transmitter or receiver. All MOR801B Power configuration parameters are stored in an EEPROM on the control module if a power supply failure occurs. figure 2-4 Top view of the control module M0070A0A.doc Id.-No 151155 Page 18 18-June-99 User’s manual for Remote Unit MOR801B Power 2.5 Duplexer The task of the duplexer is to isolate uplink from downlink, i.e. isolate transmit path from receive path. The pass bandwidth of the duplexer is the entire width of the uplink band and the downlink band. UL frequency DL frequency 824 - 849 MHz 869 - 894 MHz RF probe 30 dB figure 2-5 Top view of the duplexer M0070A0A.doc Id.-No 151155 Page 19 18-June-99 User’s manual for Remote Unit MOR801B Power 2.6 Active Combiner After passing through the RF modules, the signals will be combined by the Active Combiner module in the UL and in the DL path. The Active Combiner will be followed by the feed forward amplifier in the DL and by the Transceiver in the UL. figure 2-6 Top view of an Active Combiner module 2.7 Transceiver MFY1309 The Transceiver MFY1309 is the interface between the optic and the electrical distribution unit. The function of the Transceiver is to convert the optical signal into an electrical signal and vice versa. figure 2-7 Transceiver MFY1309 M0070A0A.doc Id.-No 151155 Page 20 18-June-99 User’s manual for Remote Unit MOR801B Power Transceiver MFY1309 Optical connectors figure 2-8 Installation position of the Transceiver The configuration of the connecting pins is shown in the following figure. connecting pins Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 GND Rx Alarm normally closed Tx Alarm common Vcc Rx Alarm common Rx Alarm normally open Tx Alarm normally closed Tx Alarm normally open figure 2-9 Configuration of the connecting pins 2.8 FSK modulator To enable remote control between the Master Unit and the Remote Units a serial interface will be implemented, in the following designated as FSK modulator. Signals from the Remote Unit will be modulated to a 10.7 MHz carrier and are fed to the optical Transceiver to be transmitted to the Master Unit via optical vibre and vice versa. M0070A0A.doc Id.-No 151155 Page 21 18-June-99 User’s manual for Remote Unit MOR801B Power 2.9 4-way-Splitter The 4-way-Splitter provides the RF-signal to the RF modules. It splits up the signal from the Receiver and provides four equal RF outputs with an attenuation of 10 dB for the RF modules. It is mounted underneath the Optical Transceiver and can be seen only, if the Transceiver is dismounted. figure 2-10 Top view of the 4-way-Splitter (Transceiver dismounted) 2.10 Measuring aids With the built-in RF probe test signals can be applied or detected. The duplexer is equipped with a probe which provides a coupling factor of 30 dB. This facilitates measurements under all operational conditions, while an antenna or a dummy load may be connected. The position of the coupler on the duplexer is shown in figure 2-5 Top view of the duplexer. 2.11 Power supply For the MOR801B Power three power supplies are necessary. Power supplies are available with different mains power. See list below for available power supplies. M0070A0A.doc Id.-No 151155 Page 22 18-June-99 User’s manual for Remote Unit MOR801B Power 115 VAC 15% / 40 - 65 Hz 230 VAC 15% / 40 - 65 Hz 185 - 320 VAC / 40 - 65 Hz 24 VDC 42 to 60 VDC 80 to 130 VDC The following figure shows the mounting position of the power supplies in the MOR801B Power cabinet. power socket (service connector*) Power supplies G0850M0 * service connector is not included in each power supply figure 2-11 Mounting position of power supplies The power supplies are equipped with a power socket, protected with two fuses. Each power supply can be switched on or off by means of an external switch. The modules of the Repeater are voltage free if all power supplies are switched off. The power socket, however, is still provided with mains power. See figure 2-12 ON / OFF position of external switch. M0070A0A.doc Id.-No 151155 Page 23 18-June-99 User’s manual for Remote Unit MOR801B Power figure 2-12 ON / OFF position of external switch Note: To switch the whole Repeater voltage free, you have to remove the fuses F1 and F2 on the screw terminal. The power supply is factory-set. 2.12 Feed forward amplifier The feed forward amplifier is the final stage which enables high output power as well as a high ICP3. One amplifier is installed for the DL Out path. figure 2-13 Top view of the feed forward amplifier M0070A0A.doc Id.-No 151155 Page 24 18-June-99 User’s manual for Remote Unit MOR801B Power 3 Functions and features 3.1 Band and channel selectivity The selectivity is achieved by highly selective filters in the IF part of the band / channel modules. 3.2 Gain setting The gain can be changed by introducing attenuation into the amplifier chain. By using a rotary switch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum in steps of 2 dB. The attenuation can be set for the UL and DL path separately. The rotary switches are mounted on the mother board. These switches are accessible through the long hole between the two RF modules (see figure 3-1 Position of rotary switches). They can be adjusted easily by means of a small screwdriver. long hole figure 3-1 Position of rotary switches For remote control an RS232 interface can be used to set the gain. The functions of the control module may be used locally by means of a VT100 terminal or a personal computer emulating the VT100 terminal. See also chapter 7.2, which deals with settings of operational parameters. M0070A0A.doc Id.-No 151155 Page 25 18-June-99 User’s manual for Remote Unit MOR801B Power 3.3 ALC In order to protect the final amplifier and the optical devices from overload and to prevent the system to generate spurious emission, the amplifier for the DL Out and the Active Combiner for the UL Out have an Automatic Level Control, designed to limit the output power to a defined level. A part of the output power is rectified, amplified and used to control an attenuator network. In order to avoid oscillation, the control amplifier has an integrating characteristic, so that a step function response obtains a delayed rise and decay. Note: The ALC protects the final amplifier and the optical devices. To keep spurious emissions below certain limits, the input power into the Repeater and the attenuation settings of the Repeater have to be considered properly. 3.4 BITE and alarms The Built-In TEst concept comprises the monitoring of the power supplies, the operational currents in the RF modules, the mother board and the remote control interface. Furthermore, the synthesizer lock and the temperature of the Repeater are monitored. There are three multicoloured LEDs mounted on the control module. The LED L3 indicates the presence of electrical power of +12VDC in the Repeater. Every alarm is indicated by the failure LEDs, L1 and L2. Position of the LEDs on the control module is shown in the following figure. figure 3-2 Position of failure LEDs M0070A0A.doc Id.-No 151155 Page 26 18-June-99 User’s manual for Remote Unit MOR801B Power All alarms can be checked by typing the ‘STATUS HIST’ command. It is possible to cancel minor alarms with no influence on the system by typing the ‘ALARMACKN’ command, e.g. ALC active, VSWR or door open. The following print screen illustrates a possible ‘STATUS HIST’ report figure 3-3 Status hist report In case a hardware failure is detected the concerning hardware module has to be replaced. An alarm can be acknowledged manually by software command. If all alarms have been acknowledged the summary error LEDs are set back to green indication. In case of mains power failure all data of the STATUS HIST list are lost. The alarm can also be sent to the OMC. The following list comprises all available alarms in the Repeater. These alarms may occur in the STATUS HIST list. M0070A0A.doc Id.-No 151155 Page 27 18-June-99 User’s manual for Remote Unit MOR801B Power NO. (7) 10 11 12 (13*) (14*) (15*) (16*) (17**) ** (...) ALARM NAME AMPLIFIER BIAS POWER SUPPLY 8 V POWER SUPPLY 12 V MAINS SYNTH DOOR VSWR ALC LITHIUM BATTERY VOLTAGE OVERTEMP INVALID LOGIN ATTEMPT I2C BUS EXT. ALARM 1 EXT. ALARM 2 EXT. ALARM 3 EXT. ALARM 4 EXT. BATTERY ALARM ACTIVE STATUS FAILURE FAILURE FAILURE FAILURE FAILURE OPEN ALARM FAILURE LOW FAILURE FAILURE FAILURE FAILURE FAILURE OVERTEMP. Alarm default settings changeable by software instruction SET ALIAS. This alarm may be activated together with the external alarms, for instance UPS temperature Optional alarms table 3-4 List of all available alarms 3.4.1 Handling of alarms As soon as the software recognizes a valid alarm, a message is transmitted to theMaster Unit. If the reason for the alarm has been cleared or if the alarm should continue, a new alarm message will not be repeated. If there was an interruption of at least one second after acknowledgement, a new alarm message will be generated. M0070A0A.doc Id.-No 151155 Page 28 18-June-99 User’s manual for Remote Unit MOR801B Power 3.4.2 Status report Two instructions enable the operator to gain knowledge of the system status. Typing the GET command will be responded by a listing of all settings of the Repeater. STATUS will be responded by a listing of all individual status information. An example is listed below for a GET1* (REP1009V1.xx) and STATUS report. The listing contains random data to demonstrate in which way these messages appear. *: Due to the fact that the report is very long, the GET report can be split in two parts. You have to type GET1 to see the first and GET2 to see the second part. The complete listing of the dialogue language with the processor of the control module including the instructions to and the messages from the system is available as a separate manual. figure 3-5 Example of a GET1 report M0070A0A.doc Id.-No 151155 Page 29 18-June-99 User’s manual for Remote Unit MOR801B Power figure 3-6 Example of a STATUS report 3.4.3 Severity levels This parameter defines five severity levels for an alarm and can be set in the alarm mask (detailed description in the software manual). The severity levels indicate how the capability of the managed object has been affected. The levels are described below and are ordered from most severe to least severe: - Critical: The critical severity level indicates that a service affecting condition has occurred and an immediate corrective action is required to restore the capability of the managed object. - Major: The major severity level indicates that a service affecting condition has developed and an urgent corrective action is required. Such a severity can be reported, for example, when there is a severe degradation in the capability of the managed object and its full capability must be restored. - Minor: The minor severity level indicates the existence of a non-service affecting fault condition and that corrective actions should be taken in order to prevent a more serious failure. Such a severity can be reported, for example, when the detected alarm condition is not currently degrading the capability of the managed object. M0070A0A.doc Id.-No 151155 Page 30 18-June-99 User’s manual for Remote Unit MOR801B Power - Warning: The warning severity level indicates the detection of a potential or impending service affecting failure before any significant effect has been caused. Action should be taken to further diagnose and correction of the problem shall prevent a more serious service affecting failure. - Disable: The disable severity level indicates that the detected failure has no influence on the system and shall not be sent to the terminal. M0070A0A.doc Id.-No 151155 Page 31 18-June-99 User’s manual for Remote Unit MOR801B Power 4 Optional equipment The following modules can be integrated as an option. 4.1 VSWR module VSWR signal is continually measured by a special VSWR module. An alarm can be given for VSWR < 10 dB. 4.2 External alarms With the following option it is possible to monitor 4 external alarms via the Repeater software. Hence the status of the connected device, e.g. UPS, can be monitored. The contacts of the alarms can be accessed at clamps on the main board (right-hand side of the Repeater). figure 4-1 Clamps for external alarms M0070A0A.doc Id.-No 151155 Page 32 18-June-99 User’s manual for Remote Unit MOR801B Power The electrical connection has to be as follows. External alarm 1 (low active) External alarm 2 (low acitve) External alarm 3 (high active) External alarm 4 (high active) Ground Configuration: 5 V / 0.5 mA max. for open collector applications. All external alarms are normally high without connection. Due to the fact that the external alarms 3 and 4 are high active, they have to be connected to ground to prevent an alarm message. The factory-set response after typing the software command STATUS EXTALARM is for instance „EXT. ALARM 1 OK“, if the alarm is not active and „EXT. ALARM 1 FAILURE“, if the alarm is active. The name for each external alarm and the name for the alarm message can be defined by the customer with the corresponding software command. The following example describes the response for the external alarms to control a UPS. Example: External alarms if the UPS is active EXTERNAL ALARM STATUS UPS alarm active Battery low ! UPS door open Battery door open or External alarms if the UPS is not active EXTERNAL ALARM STATUS UPS not active Battery OK UPS door closed Battery door closed For the DC wiring an additional cable bridge has to be installed on the control module (see figure 4-2 Cable configuration and installation position). M0070A0A.doc Id.-No 151155 Page 33 18-June-99 User’s manual for Remote Unit MOR801B Power Control module figure 4-2 Cable configuration and installation position 4.3 Battery backup module If backup is required only for the control module, low capacity batteries are available to operate the controller for at least ten minutes under normal environmental conditions. Battery backup is provided for the control module to transmit alarm information in case of power failure. The battery type is a NiCd 8.4V/300 mAh. Note: This battery backup module is provided for the control module only. The batteries are protected from deep discharge by use of a low voltage disconnect circuit. A local switch is provided to disconnect the battery backup system during maintenance to ensure that all circuits are voltage-free. The switch is located on the battery backup module. Switch ON ( default ) OFF Battery backup active Battery backup not active The module is directly plugged into the control module. During the charging process a green LED V7 on the module indicates, that the battery is charged at the moment. After finishing the process the LED V7 will be switched off. The batteries are mounted underneath the modem mounting plate (see following figure). M0070A0A.doc Id.-No 151155 Page 34 18-June-99 User’s manual for Remote Unit MOR801B Power figure 4-3 Mounting position of batteries M0070A0A.doc Id.-No 151155 Page 35 18-June-99 User’s manual for Remote Unit MOR801B Power 5 Specification 5.1 Electrical specification Frequency range Uplink 824-849 MHz; Downlink 869-894 MHz Useable bandwidth 25 MHz in the AMPS 800 band Gain 65 dB Gain variation over frequency and temperature* ±2.5 dB (±3.5 dB at extreme temperatures) Gain adjust range 30 dB in 2 dB steps Gain adjust range tolerance ±0.5 dB Return loss 15 dB @ 25°C ambient temperature Spurious/intermodulation -13 dBm max Spectral re-growth (CDMA only) -45 dBc (J-STD-008) Power supply 115 VAC 15% / 40 - 65 Hz Option: 230 VAC 15% / 40 - 65 Hz Option: 185 - 320 VAC / 40 - 65 Hz Option: 24 VDC Option: 42 to 60 VDC RF connector 7/16 female Option: N female Environmental and safety See separate leaflet *: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°C M0070A0A.doc Id.-No 151155 Page 36 18-June-99 User’s manual for Remote Unit MOR801B Power BAND AND CHANNEL SPECIFICATIONS Variable Bandwidth Channel CDMA TDMA 3 dB bandwidth 0.1 to 15.0 MHz 1.23 MHz 30 kHz Slope 3 dB to 30 dB 2 MHz 30 dB bandwith fc 900 kHz fc 60 kHz 50 dB bandwith fc 1.5 MHz fc 120 kHz Delay 6 µs < 6 µs 20 µs Delay variation (typical) 150 ns 500 ns 500 ns Far off selectivity 40 dB 60 dB 55 dB NF at Gmax 8 dB 6 dB 6 dB NF at Gmax-30 dB 13 dB 12 dB 12 dB OICP-3 at Gmax 59.0 dBm 59.0 dBm 59.0 dBm OICP-3 at Gmax -10 dB 58.5 dBm 58.5 dBm 59.0 dBm OICP-3 at Gmax -20 dB 57.5 dBm 58.0 dBm 58.5 dBm OICP-3 at Gmax -30 dB 53.0 dBm 55.0 dBm 57.0 dBm -76 dBm/Hz -96 dBm/Hz Power consumtion (standby/max power) 1 module (typ.cons) 145/220 W 130/210 W 130/210 W 4 modules (typ.cons) 180/270 W 160/240 W 160/240 W Output noise in band at Gmax Output noise out of band at Gmax All data is subject to change without notice ! M0070A0A.doc Id.-No 151155 Page 37 18-June-99 User’s manual for Remote Unit MOR801B Power 5.2 Optical specification Max. allowed optical loss Master / Remote Required optical return loss reflection + backscatter 10 dB* *optical loss up to 13 dB with slightly degraded specifications 45 dB 5.3 Mechanical specification Standard cabinet Max. Height x Width x Depth: 21.1 x 18.2 x 7.9 inches 535 x 462.5 x 200 mm Volume: approximately 45 litres Weight: approximately 103 lbs (47 kg per unit in standard configuration) The illustration of chapter 12.1 provides the dimensions and the view of the layout. 5.4 Environmental and safety For detailed information refer to the environmental and safety specification leaflet for MIKOM indoor / outdoor cell enhancers, related to ETS 300019 (European Telecommunication Standard). Operating temperature (normal temperature range): (extreme temperature range): + 5° C ... + 40° C - 33° C ... + 50° C Humidity: + 30° C/ 93 % M0070A0A.doc Id.-No 151155 Page 38 18-June-99 User’s manual for Remote Unit MOR801B Power 5.5 External electrical interfaces 5.5.1 Electrical power The Repeater MOR801B Power can be supplied with the following power supplies (mains): 115 Vac 15% 40 - 65 Hz 230 V ac 15% 40 - 65 Hz 185 - 320 Vac 40 - 65 Hz 24 Vdc 42 to 60 Vdc 80 to 130 Vdc A firmly installed mains cable is used, which is fed into the housing through a watertight cable gland. Due to safety reasons the power supply lead has to be protected by two 8 A fuses. Inside the Repeater, mains are connected to a screw terminal. See figure 5-1 Screw terminal for mains cable for the position of the two 8 A fuses. figure 5-1 Screw terminal for mains cable M0070A0A.doc Id.-No 151155 Page 39 18-June-99 User’s manual for Remote Unit MOR801B Power 5.5.2 RF connection There is a 7/16 female antenna connector at the outside of the housing accessible on the connector panel. G0850Z0 figure 5-2 Connector panel layout The 7/16 TX-downlink connector should be connected to the antenna system for the communication with the mobile units. Mobile As an option a 7/16 - N adapter is available. 5.5.3 Optical connector The Remote Unit is connected to the Master Unit via optical fibres. Therefore two optical connectors (DIN, SC/APC or FC/APC) are available at the front side of the Repeater. They are labelled with RX and TX. BTS M0070A0A.doc Id.-No 151155 Page 40 18-June-99 User’s manual for Remote Unit MOR801B Power 6 Installation to/from TX Downlink RX Uplink Repeater System to/from mobile stations BTS Master Unit Remote Unit 1 ** Remote ... Unit xx. TX Uplink RX Downlink Mobiles *: **: BTS This is possible alternativly The number of Remote Units depends on the configuration of the Master Unit figure 6-1 System description M0070A0A.doc Id.-No 151155 Page 41 18-June-99 User’s manual for Remote Unit MOR801B Power 6.1 Mechanical installation Note: Due to power dissipation the Repeater may heat up the air volume inside the cabinet and reach a very high temperature. Therefore it is necessary to mount the Repeater in the vertical plane to a wall or a mast without additional enclosure to provide sufficient ventilation. Between the housing and the wall a minimum distance must be kept in order to provide air circulation. The Repeater must be mounted in the vertical plane to a wall or a mast, which means the connectors have to be located at the bottom. Use the mounting brackets, which are part of the delivery. This will guarantee a minimum distance between the wall and the Repeater housing. The cabinet must be fixed to the wall (brackets) with four screws. Check the correspondence of the wall mounting kit and the wall. Note: M0070A0A.doc The weight of the MOR801B Power is approximately 47 kg in standard configuration. Id.-No 151155 Page 42 18-June-99 User’s manual for Remote Unit MOR801B Power Mounting procedure: Dismount the mounting brackets first. They are screwed tight to the housing with four socket head cap screws M8.0x16 (see figure below) and two tire bolts. mounting brackets figure 6-2 Wall mounting brackets Use the wall mounting sheet to mark the position of the drilling holes. Drill 4 holes and screw the mounting brackets to the wall. Attach the upper two socket head cap screws M8.0x16 to the Repeater housing. Now it is possible to hang the Repeater into the mounting brackets. Fix then the lower two socket head cap screws M8.0x16 and the 2 tire bolts. Note: The unit is heavy-weight. Make sure that a suitable mounting surface is used. Only adequate manpower is allowed to handle the system. The installation position of the Repeater follows from the installation drawing, see figure 12-1 Installation drawing of the Repeater. Make sure that there is free access to the electrical connections. The allowed bending radius of the connected cables must not be exceeded. Furthermore the Repeater shall be mounted in a way that there is free access to the individual units inside the cabinet, while the door of the Repeater is open. Therefore keep a clearance distance of 1 m on each side, above and below the unit. See following figure 6-3 Clearance distance. M0070A0A.doc Id.-No 151155 Page 43 18-June-99 User’s manual for Remote Unit MOR801B Power figure 6-3 Clearance distance M0070A0A.doc Id.-No 151155 Page 44 18-June-99 User’s manual for Remote Unit MOR801B Power 6.2 Electrical installation Note: ESD precautions have to be observed! Before working inside the cabinet use the available grounding system to connect ESD protection measures. The electrical installation has to be performed in accordance with the safety regulations of the local authorities. Due to safety reasons the electrical installation must be performed by qualified personnel. The cover of this unit should not be opened while power is applied. Subsequent installation, commissioning and maintenance activities that require the unit to be powered with the cover open shall only be carried out by suitably qualified personnel 6.2.1 Grounding Grounding has to be performed by all means. Therefore a grounding bolt is provided at the cabinet. An earth bonding cable will be mounted in the factory and will be delivered with the unit. Don’t use the grounding screw for connecting external devices. The complete grounding kit is part of the delivery schedule. figure 6-4 Grounding kit M0070A0A.doc Id.-No 151155 Page 45 18-June-99 User’s manual for Remote Unit MOR801B Power 6.2.2 Power connection Before connecting electrical power to the Repeater grounding has to be performed. The Repeater is equipped with a firmly connected power cord. Due to safety reasons the power supply lead of the Repeater has to be protected with two 8 A fuses, type MT. In the event the length of the power cord should not be sufficient it can be replaced by a longer cable. Note: figure 6-5 Screw terminal If the power supply lead has to be replaced use a cable of the same quality. 6.2.3 Connection of the antenna cable The Repeater has a female antenna connector 7/16 (or N with adapter). For mounting the corresponding cable connector we recommend to refer to the applicable documentation of the respective connector manufacturer. The bending radius of the antenna cable must remain within its specification. This will warrant proper operation of the system; otherwise changes in the electrical behaviour of the cable might occur which could cause malfunction of the Repeater system. Note: M0070A0A.doc It is sufficient to fix the 7/16 (or N) antenna connector hand-screwed. Any use of a tool (like tongs) might cause damage to the connector and thus lead to malfunctioning of the Repeater. Id.-No 151155 Page 46 18-June-99 User’s manual for Remote Unit MOR801B Power 6.2.4 Connecting fibre optic cables The standard transmission of the optical signals is carried out by means of an optical fibre pair for each Remote Unit. Note: Extreme care should be taken when connecting and disconnecting the fibre optic cable. Scratches and dust significantly affect system performance and may permanently damage the connector, necessitating re-termination. Always use protective caps on fibre optic connectors and receptacles when not used. The structure of the cable is not critical. However, demands of the site as for example rodent protection and so on have to be kept in mind. The optical fibre is a single mode fibre. The type is E9/125 with the following minimum requirements. Attenuation Dispersion < 0.3 dB/km @ 1300 nm < 3.5 ps/nm*km @ 1300 nm The allowed bending radius of the optical fibres must be kept by all means at any time. The pig tails for the connection between Master and Remote Unit must have a sufficient length. A protection for the feeding into units has to be given. The system attenuation of the optical fibres including the connectors must not exceed 10 dB. Less than 5 dB is desired. The system attenuation and the attenuation of the opical components have to be determined. This can be achieved by measuring the attenuation and the reflection with an appropriate measuring instrument. For pig tails a total value of < 0.4 dB ( measured to a reference plug ) can be assumed due to the dead zone of the reflectometre. These measurements have to be made with a sufficient length of optical fibre in front of and behind the device to be measured. The fibre cables should be terminated with the same type of connector (DIN 8° or SC/APC 8°) as is used in the unit. The fibre optic cables are connected to the optical Transceiver and receiver. Note: M0070A0A.doc Angled connectors are not compatible with straight optical connectors; non-compatibility of connectors will result in permanent damage to both waiting connectors. Id.-No 151155 Page 47 18-June-99 User’s manual for Remote Unit MOR801B Power Before connecting the fibre cables, follow the procedures below to ensure proper performance. It is important that these procedures be performed with care: 1. Remove fibre optic protective caps. 2. Do not bend the fibre optic cable in a tight radius (<4 cm) as this may cause cable damage and interrupt transmission. 3. Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of the fibre optic cable that will be inserted in the optical connectors on the donor interface box. 4. Blow the end dry with clean, dry compressed air. 5. Vigorously blow out the laser receptacle with clean, dry compressed air to remove any particulate matter. 6. Connect the fibre optic cables by inserting the cable end into the laser receptacle and aligning the key (on the cable end) with the keyed slot. 7. Do not use any index matching gels or fluids of any kind in these connectors. Gels are intended for laboratory use and attract dirt in the field. M0070A0A.doc Id.-No 151155 Page 48 18-June-99 User’s manual for Remote Unit MOR801B Power 7 Setting to work 7.1 Preparation Note: It is not allowed to operate the Repeater without termination of the antenna connections! The termination can be performed by the antenna connection as well as a dummy load or the 50-Ohm-terminated connection of a measuring instrument. Before bringing the Repeater system into service it is necessary to measure the antenna isolation. The Repeater system has its maximum available gain when the attenuation is set to zero. On site the maximum allowed gain is 15 dB less than the value of the antenna isolation. In order to check the function of the Repeater system on site it is advisable to operate the Repeater system with 50 Ohm termination. This makes it possible to set the necessary gain and to test the set value without the necessity of transmitting on air. In order to perform settings the Repeater has to be opened. Please ensure not to damage the seals which are on the modules situated on the RF modules inside of the Repeater, because this would lead to risk the success of warranty claims. After taking the Repeater into service following signals occur during the boot process. Internal LED L1 green red Flashes red short time Internal LED L2 green red Flashes red short time Internal LED L3 green Cause Power on state, Software boot starts Software boot starts Software is running table 7-1 LED indication M0070A0A.doc Id.-No 151155 Page 49 18-June-99 User’s manual for Remote Unit MOR801B Power 7.2 Setting of operational parameters Attenuation of the Repeater can be set manually, locally or remotely. Frequency can be set locally and remotely. There are three different possibilities to set the operational parameters: -manual settings by means of rotary switches -local control via RS232 interface and PC -remote control via Master Unit 7.2.1 Manual setting of the attenuation by means of rotary switches The manual mode allows the user to set the required attenuation by means of rotary switches. With a small screwdriver, which fits through the long holes of the RF modules, the values can be adjusted by turning the switch carefully to the desired position. Note: To enable manual settings of parameters the mode switch (DIP-Switch 1) has to be changed from OFF to ON. The DIP-Switch is mounted on the control module, located on the left-hand side of the Repeater. DIP-Switch 1 figure 7-2 Position of the DIP-Switch 1 M0070A0A.doc Id.-No 151155 Page 50 18-June-99 User’s manual for Remote Unit MOR801B Power The gain can be set by introducing attenuation into the amplifier chain. By using a rotary switch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum in steps of 2 dB. The attenuation can be set for the UL and DL path separately. The rotary switches are mounted on the mother board. These switches are accessible through the long hole between the two RF modules ( see figure 7-3 Position of the rotary switches). They can be adjusted easily by means of a small screwdriver. long hole figure 7-3 Position of the rotary switches A label on the RF module, located next to the rotary switch, illustrates the usage of the rotary switch (see figure 7-4 Rotary switches and label). Note: figure 7-4 Rotary switches and label Gain can be changed independently for the uplink and downlink path. DIP-Switch configuration: M0070A0A.doc Id.-No 151155 Page 51 18-June-99 User’s manual for Remote Unit MOR801B Power DIP-Switch ON manual remote mode n.c. software download manually controlled OFF (default values) auto local mode n.c. software download controlled by software table 7-5 DIP-switch configuration 7.2.2 Settings via personal computer as terminal Instead of manually setting operational parameters via rotary switches it is also possible to use the functions of the control module. The local mode for settings via PC has to be set. Therefore the DIP-Switch 2 has to be at position OFF. DIP-Switch 2 figure 7-6 DIP-switch 2 for local mode M0070A0A.doc Id.-No 151155 Page 52 18-June-99 User’s manual for Remote Unit MOR801B Power A VT100 terminal or a PC with VT100 emulation can be connected to the control module SM2009 by a standard RS232 cable, if necessary in connection with an adapter 9 to 25. Cable Connections PC 9 contact SUB - D- Connector male PC PIN Control Module SM2009 9 contact SUB - D- Connector male RS 232 MOR801B Power PIN The following communication mode between control module and VT100 is set initially. 9600 baud - 8 bit - no parity -1 stopbit These settings can only be changed after connection of the terminal. Modifications are possible by software commands. Note: M0070A0A.doc Settings on the Repeater can be performed after the following procedure only. Id.-No 151155 Page 53 18-June-99 User’s manual for Remote Unit MOR801B Power After connecting the PC to the Repeater, following procedure is necessary to get access to the program. MIKOM REPEATER MOR801B - SM2009 - SW: REP1007V1.11 ENTER <.>TO LOGIN Type the two keys ( . ) FULLSTOP and () ENTER 1. Step: You have to type the keys: 2. Step: UserID1 The input is case sensitive, no blanks. After three mistrial follows disconnection. 3. Step: ENTER PASSWORD You have to enter: Note: ENTER USER ID You have to enter: Note: P-word1 The input is case sensitive, no blanks. After three mistrials follows disconnection. 7.2.3 Remote control via Master Unit The Remote Unit can be set remotely through the optical interface by devices connected to the Master Unit. M0070A0A.doc Id.-No 151155 Page 54 18-June-99 User’s manual for Remote Unit MOR801B Power 8 Trouble shooting All Repeaters are factory-set to „Power down disabled“ status, this means the channel group is active. To switch off the channel group use the software command „PWRDOWN enabled“. (You find a detailed description in the software manual.) 8.1 Error indication = LED on - = LED off Internal LED L1 green red Internal LED L2 green red Internal LED L3 green Cause No power. Check presence of power at the input; replace fuse according to chapter 9.3, check battery backup module Indicates a summary failure 8.2 Boot process Following signals occur during boot process. Internal LED L1 green red Internal LED L2 green red Flashes red short time Flashes red short time M0070A0A.doc Id.-No 151155 Internal LED L3 green Cause Power on state, Software boot starts Software boot starts Page 55 Software is running 18-June-99 User’s manual for Remote Unit MOR801B Power 8.3 Alarm monitoring with the STATUS HIST command Check alarms with ‘status hist‘ command. 1. If a hardware module is damaged, replace corresponding hardware module. 2. Minor alarms with no influence on the system can be cancelled by confirming the alarm with the ‘alarmackn’ command, e.g., ALC active, VSWR, RSSI or DOOR OPEN. 3. If all alarms have been acknowledged the summary error LEDs will be set back to green indication. 4. In case of mains power failure the contents of the actual STATUS HIST list is lost. For a complete list of available alarms, see table 3-4 List of all available alarms 8.4 Power supply The output voltage is factory set and should not be changed. 8.5 General remarks After a software download previous user settings ( data default values ) might be overwritten. Before you start a software download save the set values for: centre frequency attenuation ALC threshold If an ALC or AMPBIAS alarm occurs during installation or commissioning an user error might be the cause, due to wrong measurements. M0070A0A.doc Id.-No 151155 Page 56 18-June-99 User’s manual for Remote Unit MOR801B Power 9 Maintenance 9.1 General Note: The Repeater does not require preventative maintenance measures. It is only recommended to replace the RAM/RTC battery after three years usage as a prophylactic measure. The nominal lifetime of these batteries is five years under normal environmental conditions. In the event of a malfunction it is advantageous to check the status of the antenna systems as well as the continuity of the entire cabling including connectors, before replacing the modules. Maintenance on the Repeater shall be performed only by replacing modules. Soldering on printed circuit boards shall be avoided. In order to sustain warranty take care not to damage unintentionally the seals on the modules. The spare part list, consequently, contains only units, which can be replaced without tuning or complex soldering work. Note: figure 9-1 Top view of the Repeater Defect parts should only be replaced by original parts from MIKOM. All interventions inside the housing are at one’s own risk. During maintenance ensure that the Repeater has been disconnected from mains. Open the lock at the connector panel and remove the cover plate. To open the housing use a Torx key and unscrew the four Torx screws. 9.2 Replacement of the fuses (mains) The mains cable is protected with two fuses F1 and F2 8A type MT. They are accessible inside of the Repeater at the fuse terminal on the right-hand side. Open the screw plug for the fuse and take out the fuse. Note: Use only fuses of the same type and the same rating when replacing! See figure 9-2 Fuse terminal for position of the 8A fuses. M0070A0A.doc Id.-No 151155 Page 57 18-June-99 User’s manual for Remote Unit MOR801B Power figure 9-2 Fuse terminal 9.3 Replacement of the power supply fuse Each power supply is protected with a fuse 10 A / 35 V. The fuse is mounted outside of the power supply housing. Note: Use only fuses of the same type and the same rating when replacing! figure 9-3 Position of power supply fuse 9.4 Replacement of the mains cable The Repeater will be delivered with a firmly connected mains cable. In case the length of the delivered mains cable should not be sufficient or in case of a defect, the mains cable can be replaced. Note: M0070A0A.doc Disconnect Repeater from mains first. Id.-No 151155 Page 58 18-June-99 User’s manual for Remote Unit MOR801B Power Remove the clamping profile at the outside of the housing by pulling at the mains cable. Open the PG9 threaded joint with a spanner size 17. Inside the housing remove the plastic cable clip by unscrewing the tallow-drop screw. Then use a small screwdriver and open the screws of the fuse terminal. Now the mains cable can be removed by pulling at the cable. For the installation of a new cable strip the isolation of a new cable to the length of 18 cm. Put the screw of the cable gland over the cable then use the joint rubber and pull it over the cable. This will guarantee a tight connection. Now insert the cable. Inside the housing pull an insulated tube with the length of 8 cm over the wires. Now close the PG9 threaded joint. Screw the wires to the fuse terminal. Fix the cable with the plastic cable clip. Put the cable in the guide shaft and close it with the clamping profile. 9.5 Replacement of the RAM / RTC battery The RAM / RTC battery of the control module has to be replaced in case of memory loss or as a preventive measure after approximately three years usage. The RAM / RTC battery is mounted on the left-hand side of the Repeater underneath the dummy battery backup module First remove the whole dummy battery backup module ( see figure 9-5 Position of dummy battery backup module ), which is plugged into the control module. Take off the Lithium battery by means of a small screwdriver, placed between the battery and the battery socket. The type of the battery is CR 2450 Lithium 3 V / 500mAh, manufacturer is RENATA. After replacement of the RAM battery, the control module has its basic settings, date and time have to be set to the actual value. M0070A0A.doc Id.-No 151155 Page 59 18-June-99 User’s manual for Remote Unit MOR801B Power dummy battery backup module RAM/RTC battery Note: figure 9-4 Position of RAM/RTC battery Before replacing the battery, disconnect the Repeater from mains. Observe the rules for changing Lithium batteries. Wrong connection or treatment may result in bursting of the battery and dissemination of hazardous substances. Don’t try to charge this battery. 9.6 Replacement of the dummy battery backup module The dummy battery backup module is accessible after opening the housing on the left-hand side. Before you are able to remove the module from the socket, release the three snap-in lockings. M0070A0A.doc Id.-No 151155 Page 60 18-June-99 User’s manual for Remote Unit MOR801B Power dummy battery backup module figure 9-5 Position of dummy battery backup module 9.7 Replacement of the duplexer This description is valid for the one channel configuration of the Repeater only. For different configurations refer to the assembly guide for the Repeater. Remove the semi-rigid cables which connect the DL Output with the feed forward amplifier by loosening the SMA connector. Use a torque wrench. Then remove the semi-rigid cable from the mother board. It is recommended not to remove the amplifier which is mounted on the backside of the duplexer. A new duplexer will be delivered with a premounted amplifier. The cables have to be connected as shown below. G0850M1 figure 9-6 Cable configuration of the duplexers M0070A0A.doc Id.-No 151155 Page 61 18-June-99 User’s manual for Remote Unit MOR801B Power Unscrew the four counter sunk screws M3 at the connector panel of the Repeater. See figure 9-7 Connector panel layout. G0850Z0 figure 9-7 Connector panel layout 9.8 Replacement of RF modules To remove the RF modules, disconnect the SMA connectors by means of a torque wrench. If the Repeater is equipped with TDMA modules, the external filter on top of the modules must be dismounted beforehand. The external filter box covers two of the socket head cap screws the TDMA module is fixed with. Unscrew the socket head cap screw on top of the external filter box, pull the box carefully off and continue the dismounting procedure as described below. Unscrew six socket head cap screws by means of a hex socket key. Pull carefully by means of the mounting strap, fixed on the module (see figure 9-8 Top view of an RF module) and take off the module. M0070A0A.doc Id.-No 151155 Page 62 18-June-99 User’s manual for Remote Unit MOR801B Power Socket head cap screws Mounting strap * *: TDMA and CDMA modules are equipped with mounting straps on the left and on the right side. figure 9-8 Top view of an RF module Connecting the RF modules depends on the number of channels your Repeater is equipped with, i.e. with one up to four channels. Each configuration has got a different cabling. See assembly guide of the channel modification kits for the cabling of the RF modules dependent on the configuration of the Repeater. M0070A0A.doc Id.-No 151155 Page 63 18-June-99 User’s manual for Remote Unit MOR801B Power For the exchange of an RF module or the installation of a new RF module, the slave address of the synthesizer has to be set. This can be done by means of hex-coded rotary switches mounted on the lower side of the modules (figure 9-9 Position of hex coded rotary switches). Hex-coded rotary switch for DL Hex-coded rotary switch for UL figure 9-9 Position of hex coded rotary switches The synthesizer address must be set like shown in the following table: Address UL DL RF module Channel one Channel two Channel three Channel four table 9-10 Address of synthesizer Instructions for band selective modules with variable bandwith can be found in a seperate document. 9.9 Replacement of the control module SM 2009 The control module is a Printed Circuit Board situated on the left-hand side of the Repeater. Disconnect the DC cable from power supply. Disconnect the flat cable. Remove the battery backup module and remove the Tyrap which is fixed to the control module. Take off the whole control module completely with mounting plate by unscrewing four tallow drop screws M4. M0070A0A.doc Id.-No 151155 Page 64 18-June-99 User’s manual for Remote Unit MOR801B Power For mounting proceed in reverse order. Position of the control module in the Repeater is illustrated in figure 9-11 Position of control module. figure 9-11 Position of control module 9.10 Replacement of power supplies Note: Ensure that mains are disconnected. There are three power supplies mounted in the Repeater housing, two on each side. Open the Repeater to get access to the devices. Remove all connected cables from the clamps of the power supply. Try to loose the plug by means of a small screwdriver placed between the plug and socket. ON Fuse 10A / 35V figure 9-12 Power supply M0070A0A.doc Id.-No 151155 Page 65 18-June-99 User’s manual for Remote Unit MOR801B Power The power supply is fixed to the Repeater housing by means of two special nuts M4. After loosening the screws the power supply can be removed. To open these screws a special key with a spherical head is required (This key is part of the delivery). Place a small screwdriver between the Repeater housing and the power supply to loose the device. Note: figure 9-13 Position of special-nut M4 Don’t forget to put heat conducting paste on the mounting side for installation of a new power supply. Use the conducting paste, which is included in the spare parts kit. 9.11 Replacement of Active Combiner modules The Active Combiner modules are mounted on both sides of the Repeater. Disconnect all SMA connectors by means of a torque wrench. Unscrew two counter sunk screws M3x20mm. See figure 9-14 Position of counter sunk screws on Active Combiner. M0070A0A.doc Id.-No 151155 Page 66 18-June-99 User’s manual for Remote Unit MOR801B Power counter sunk screws figure 9-14 Position of counter sunk screws on Active Combiner The cabling of the Active Combiners depends on the configuration of the Repeater. For correct connections see assembly guide for the channel modification kits. 9.12 Replacement of feed forward amplifier There is one amplifier mounted on the right-hand side of the Repeater. It is fixed to the housing by means of 6 socket head cap screws M4x25. A special reset board is connected to the 15 pole SUB-D connector. (see figure 9-15 Position of the feed forward amplifier reset board) This reset board is part of the feed forward amplifier. A new feed forward amplifier will be delivered with a premounted reset board. M0070A0A.doc Id.-No 151155 Page 67 18-June-99 User’s manual for Remote Unit MOR801B Power Reset board figure 9-15 Position of the feed forward amplifier reset board Remove the ready made cable which is plugged to the 15 pole SUB-D connector of the reset board. Unscrew the screw clip first. The SMA connectors can be removed only after dismounting the amplifier. Position of the feed forward amplifier is illustrated in figure 9-16 Position of feed forward amplifier (Right-hand side of Repeater). feed forward amplifier figure 9-16 Position of feed forward amplifier (Right-hand side of Repeater) M0070A0A.doc Id.-No 151155 Page 68 18-June-99 User’s manual for Remote Unit MOR801B Power 9.13 Replacement of the FSK modulator To remove the FSK modulator disconnect all connected cables. Remove the two tallow drop screws which connect the FSK modulator with the MFY1309. The device can be removed. figure 9-17 FSK modulator 9.14 Replacement of the Transceiver MFY1309 To remove the Transceiver dismount the FSK modulator which is fixed with two screws M3 on top of the Transceiver. Disconnect all cables. Then unscrew the four counter sunk screws M3 at the connector panel. Now you can remove the Transceiver MFY1309. FSK modulator Transceiver MFY figure 9-18 Installation position M0070A0A.doc Id.-No 151155 Page 69 18-June-99 User’s manual for Remote Unit MOR801B Power 10 Spare parts list The following list contains all parts available for the MOR801B Power . The configuration of the delivered unit meets the requirements of the customer and can differ depending on the state of delivery. Designation Id.-No. Mounting material Basic Module TDMA Extension Module TDMA Basic Module CDMA Extension Module CDMA Basic Module var. BW Extension Mod. var. BW Duplexer UL Input 824.04 - 848.97 MHz Feedforward Amplifier 869 - 894 MHz Transceiver MFY1309 DIN Connector Transceiver MFY1309 SC Connector FSK Modulator 10,7 MHz Power Supply 230 Vac 15% 14 - 65 Hz Ger plug Power Supply 230 Vac 15% 14 - 65 Hz UK plug Power Supply 230 Vac 15% 14 - 65 Hz no plug Power Supply 24Vdc no plug Power Supply 185 - 320 Vac 40 - 65 Hz no plug Power Supply 115 Vac 15% 40 - 65 Hz USA plug Power Supply 42 - 60 Vdc no plug Power Supply 80 - 130 Vdc no plug SW MOB100 V1.10 Control Unit SM2009 SW SLV1007 V1.01 SW SLV1009 V1.04 Manual SW SLV1009 V1.xx Dummy Battery Backup Module Battery Backup Module Sparepart Kit Wall mounting Kit Main Board 26V version Main Board 26V version Active Combiner DL 869 - 894 MHz Active Combiner UL 824 - 849 MHz 4-way-Splitter Termination Resistor Ready-made cable data Ready-made cable DC Ready-made cable data 150521 148712 148710 148713 148709 148715 148944 148334 148630 143092 146614 145820 138305 142832 144306 145504 148812 141230 144946 145524 143055 143051 146278 147956 148354 143750 143052 146200 146179 149778 149777 148687 148888 150728 33167 149936 149928 148576 M0070A0A.doc Id.-No 151155 Page 70 18-June-99 User’s manual for Remote Unit MOR801B Power Ready-made cable DC Ready-made cable DC female headers 6 contacts 4 External Alarms option Kit Adapter 7/16 male N female Mother board Manual for MOR801B Power Assembly guide for modification kits Modification Kit for one channel Modification Kit for two channels Modification Kit for three channels Modification Kit for four channels 149648 150753 147710 112425 147024 151111 151045 149917 149918 150529 149920 table 10-1 Spare parts list M0070A0A.doc Id.-No 151155 Page 71 18-June-99 User’s manual for Remote Unit MOR801B Power 11 Configuration list The actual configuration of the Repeater system has been entered on a separate list at delivery. This configuration list is subject of the delivery schedule providing actual information of part number, Id. number, serial number and revision status of the Repeater. Whenever parts should be replaced the user is kindly asked to update the list. See sample below: Remote Unit MOR 801B Id.-No.: 147359 SN: Part name Id.-No. Rev SN Basic Module Extension Module Power Supply Duplexer UL input Feed Forward amplifier Transceiver MFY1309 FSK Modulator 10.7 MHz Control Unit SM2009 SW SLV100x Battery Backup Module Mother Board SW MOB100 Connecting Board Active Combiner *** *** *** *** *** *** Date: _________________ QA: ________________________ figure 11-1 Sample of a configuration list M0070A0A.doc Id.-No 151155 Page 72 18-June-99 User’s manual for Remote Unit MOR801B Power 12 Appendix 12.1 Installation drawing of the Repeater figure 12-1 Installation drawing of the Repeater M0070A0A.doc Id.-No 151155 Page 73 18-June-99 User’s manual for Remote Unit MOR801B Power 12.2 Top view of the Repeater (left-hand side , four channel configuration) figure 12-2 Top view of the Repeater (left-hand side, four channel configuration) M0070A0A.doc Id.-No 151155 Page 74 18-June-99 User’s manual for Remote Unit MOR801B Power 12.3 Top view of the Repeater (right-hand side, four channel configuration) figure 12-3 Top view of the Repeater (right-hand side, four channel configuration) M0070A0A.doc Id.-No 151155 Page 75 18-June-99 User’s manual for Remote Unit MOR801B Power 12.4 One channel configuration –block diagram and cabling figure 12-4 Block diagram of one channel Repeater M0070A0A.doc Id.-No 151155 Page 76 18-June-99 User’s manual for Remote Unit MOR801B Power figure 12-5 Cabling of one channel Repeater M0070A0A.doc Id.-No 151155 Page 77 18-June-99 User’s manual for Remote Unit MOR801B Power 13 Index Abbreviations 8 Active Combiner 20, 66 Address of MIKOM 11 Alarm monitoring 56 Alarms External alarms 32 Handling of 28 Indication of 26 List of all alarms 28 ALC 26 Antenna connector 40 Antenna connectors 46 Antenna isolation 49 Gain Local settings 25, 51 Setting via PC 52 Grounding 45 Health and safety warnings 10 I²C-Bus 18 Ident numbers 70 Installation Electrical 46 Mechanical 42 Interfaces 18 RS232 18 International sales offices 12 Battery backup 34 BITE 26 Boot process 55 LEDs 26 Local settings 50 Channel Setting via PC 52 Clamping profile 59 Connector type 7/16 female 40 Contents of delivery 9 Control module 18 Maintenance 57 Measurements of VSWR signals 32 MFY1309 20 Mother board 17 Mounting brackets 43 DIP-Switch 52 Dummy battery backup module 60 Duplexer 19, 61 Optical connectors 40 Optional modules 32 EEPROM 18 Environmental and safety 38 ESD precautions 11 Power supply 22 Replacement of 66 Feed forward amplifier 24 Fibre optic cable 47 FSK modulator 21 M0070A0A.doc Id.-No 151155 Page 78 18-June-99 User’s manual for Remote Unit MOR801B Power RAM / RTC battery 59 Remote control 25 via Master Unit 54 RF module 62 Rotary switch To set the gain 51 Setting of operational parameters 50 Setting to work 49 Severity levels 30 Specifications Optical 38 Splitter 22 Status report 29 Test probe 22 Transceiver MFY 20 Trouble shooting 55 M0070A0A.doc Id.-No 151155 Page 79 18-June-99
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 1999:06:24 18:59:39 Producer : Acrobat Distiller 2.1 for Windows Modify Date : 1999:06:24 19:03:05 Page Count : 79EXIF Metadata provided by EXIF.tools