Andrew Wireless Innovations Group RPT-NODEC843 Cellular Repeater User Manual M0121A1A uc
Andrew Wireless Innovations Group Cellular Repeater M0121A1A uc
Users Manual
User’s Manual for Node C Prototype Network Elements with Interface Unit ID No: 161692 PRELIMINARY Page 1 User’s Manual for Node C Network Elements © Copyright 2004 Mikom GmbH All rights reserved. All information contained in this manual has been revised thoroughly. Yet Mikom An Andrew Company accepts no liability for any omissions or faults. Mikom An Andrew Company reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Mikom GmbH An Andrew Company, 16-February-2004 Page 2 M0121A1A_uc.doc TABLE OF CONTENTS GENERAL 1.1 ABBREVIATIONS 1.2 HEALTH AND SAFETY WARNINGS 1.3 PREAMBLE 1.4 INTERNATIONAL CONTACT ADDRESSES INTRODUCTION 10 11 2.1 PURPOSE 11 2.2 THE NODE C NETWORK ELEMENT 11 2.3 QUICK START CHECKLIST 12 INSTALLATION 13 3.1 3.1.1 3.1.2 3.1.3 3.1.4 MECHANICAL INSTALLATION General Wall Mounting Procedure Connection Option Pole Mounting Procedures 13 13 14 16 17 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 ELECTRICAL INSTALLATION General Grounding Power Connection Connection of the Antenna Cables Connection of Cable Bridge Connections for Optional Equipment 20 20 21 22 23 23 24 4.1 COMMISSIONING 25 GENERAL 25 4.2 SOFTWARE SETUP 4.2.1 Remote Control 4.2.2 Connection Devices 4.2.3 Connection Procedures 4.2.3.1 Setup Overview 4.2.3.2 Installing the USB driver 4.2.3.3 Direct connection for Windows XP 4.2.3.4 Modem connection for Windows XP 4.2.3.5 Direct connection for Windows 2000 4.2.3.6 Accessing the web page 4.2.4 Main Menus of the Web Page 4.2.4.1 Setup Wizard 4.2.4.2 Connectivity and Upload 4.2.4.3 Technician Setup 4.2.4.4 Alarm Management 26 26 26 26 26 27 28 38 48 60 61 61 63 64 65 4.3 66 TROUBLESHOOTING ID No: 161692 PRELIMINARY Page 3 User’s Manual for Node C Network Elements FUNCTIONAL DESCRIPTION 69 5.1 GENERAL 69 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 FEATURES OF THE NODE C Filters Digital ICE (Digital Interference Cancellation Equipment) VSWR (Voltage Standing Wave Ratio) RSSI (Receive Signal Strength Indication) Alarmforwarding External Alarms Summary Alarm 72 72 72 73 73 73 74 75 5.3 5.3.1 5.3.2 5.3.3 5.3.4 5.3.5 5.3.6 5.3.7 COMPONENTS OF THE NODE C AND INTERFACE UNIT Duplexer RF and DC Distribution Unit Digital Channel Module (DCM) Uplink Final Amplifier Downlink Final Amplifier Distribution & Alarm Board Power Supply 76 76 78 79 80 80 82 83 5.4 OPTIONAL EQUIPMENT 5.4.1 Modem with Battery Backup 5.4.1.1 Initstrings 5.4.1.2 Wireless Modem 5.4.1.3 Battery Backup 5.4.2 PSU Redundancy 5.4.3 High Rejection Filter 83 83 84 84 85 86 86 87 MAINTENANCE 6.1 GENERAL 87 6.2 6.2.1 6.2.2 6.2.3 6.2.4 REPLACEMENT OF COMPONENTS Power Supply Battery Backup Fan Unit Modem 87 88 89 89 90 APPENDIX 91 7.1 7.1.1 7.1.2 ILLUSTRATIONS Cabinet Drawings Layout 91 91 93 7.2 7.2.1 7.2.2 7.2.3 SPECIFICATIONS Electrical Specifications Mechanical Specifications Specifications for Optional Equipment 96 96 98 98 7.3 7.3.1 7.3.2 PARTSLISTS Interface Unit Node C INDEX Page 4 99 99 100 101 M0121A1A_uc.doc FIGURES AND TABLES figure 3-1 Positions of drilling holes........................................................................................14 figure 3-2 Wall mounting procedure .......................................................................................15 figure 3-3 Connection option ..................................................................................................16 figure 3-4 Cabinet combining kit.............................................................................................16 figure 3-5 Pole mounted systems...........................................................................................17 figure 3-6 Back-to-back pole mounting...................................................................................18 figure 3-7 Pole mounting two systems ...................................................................................19 figure 3-8 Grounding bolts......................................................................................................21 figure 3-9 Grounding a system ...............................................................................................21 figure 3-10 Power supply plug................................................................................................22 figure 3-11 Mains connector...................................................................................................22 figure 3-12 Front view of antenna connections ......................................................................23 figure 3-13 Connector panel of the Node C............................................................................24 figure 3-14 Connector panel of the Interface Unit ..................................................................24 figure 4-1 Front and top cover screws....................................................................................25 figure 4-2 Position of mains power switch ..............................................................................25 figure 4-3 USB and null modem cable connection .................................................................27 figure 4-4 Home page of web interface ..................................................................................60 figure 4-5 Setup Wizard..........................................................................................................61 figure 4-6 Connectivity and Upload menu ..............................................................................63 figure 4-7 Technician Setup menu .........................................................................................64 figure 4-8 Alarm Management menu......................................................................................65 figure 5-1 DC block diagram of a Node C ..............................................................................69 figure 5-2 Configuration of a Node C network element ..........................................................70 figure 5-3 RF path of a Node C, exemplary............................................................................71 figure 5-4 Configuration of external alarm clamps..................................................................74 figure 5-5 Summary alarm relay .............................................................................................75 figure 5-6 Layout of a Node C 1943 and Interface Unit..........................................................76 figure 5-7 Duplexer, DL IN......................................................................................................77 figure 5-8 Duplexer, UL IN, with integrated diversity filter ......................................................77 figure 5-9 RF / DC distribution unit .........................................................................................78 figure 5-10 DCM (UL or DL part) ............................................................................................79 figure 5-11 Uplink final amplifier .............................................................................................80 figure 5-12 Node C x37 DL final amplifier ..............................................................................80 figure 5-13 Node C x43 DL final amplifier, new type ..............................................................81 figure 5-14 Node C x43 DL final amplifier, former version .....................................................81 figure 5-15 Distribution & alarm board....................................................................................82 figure 5-16 Power supply........................................................................................................83 figure 5-17 Battery backup module, exemplary......................................................................85 figure 6-1 Power supply screws .............................................................................................88 figure 6-2 Location of battery backup .....................................................................................89 figure 6-3 Fan unit screws ......................................................................................................89 figure 6-4 Fan connector cable...............................................................................................90 figure 6-5 Mounting plate of modem.......................................................................................90 figure 7-1 Cabinet of a Node C...............................................................................................91 figure 7-2 Cabinet of a Node C Interface Unit ........................................................................92 figure 7-3 Layout of the Node C 1937, exemplary..................................................................93 figure 7-4 Layout of the Node C 1943, exemplary..................................................................94 figure 7-5 Layout of the Interface Unit, exemplary .................................................................95 ID No: 161692 PRELIMINARY Page 5 User’s Manual for Node C Network Elements table 1-1 List of international contact addresses ....................................................................10 table 3-1 Mounting distance ...................................................................................................14 table 3-2 Required length of thread-bolts and cable bridge ...................................................17 table 3-3 Components of pole mounting kits ..........................................................................18 table 4-1 Assisted antenna tuning ..........................................................................................62 table 5-1 Connections of RF / DC distribution unit .................................................................78 table 5-2 Standard initstring for modem .................................................................................84 table 6-1 Specified torques for various screw types...............................................................88 Page 6 M0121A1A_uc.doc 1 General 1 GENERAL 1.1 ABBREVIATIONS A/D ALC ARFCN BITE BTS CDMA CF CFO D/A D-ICE DCM DL DSP EMIF ESB ESD ETSI FPGA FRU I2C Bus ICE ID No IF LE LMT LVPECL MSPS NCO OMC PCMCIA PLL PSTN RF RLP RSCP RSSI RTC RX SCL SDA SMS TS UL UMTS UPS VSWR WCDMA Analogue to Digital Converter Automatic Level Control Absolute Radio Frequency Channel Number Built In Test Equipment Base Transceiver Station Code Division Multiple Access Center Frequency Center Frequency Offset Digital to Analogue Converter Digital Interference Cancellation Digital Channel Module Downlink Digital Signal Processor External Memory Interface Embedded System Block Electrostatic Discharge European Telecommunication Standards Institute Field Programmable Gate Array Field Replaceable Unit Inter Integrated Circuit Bus (Philips) Interference Cancellation Equipment Identification Number Intermediate Frequency Logic Elements Local Maintenance Terminal Low Voltage Positive Emitter Coupled Logic Mega Samples Per Second Numerically Controlled Oscillator Operation and Maintenance Centre Personal Computer Modem Communication International Association Phase Lock Loop Public Switched Telephone Network Radio Frequency Radio Link Protocol Received Signal Code Power Receive Signal Strength Indication Real Time Clock Receiver Serial Clock Serial Data Short Message Service Transmitter Uplink Universal Mobile Telecommunication System Uninterruptible Power Supply Voltage Standing Wave Ratio Wide-band Code Division Multiple Access ID No: 161692 PRELIMINARY Page 7 User’s Manual for Node C Network Elements 1.2 HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 4. Keep operating instructions within easy reach and make them available to all users. 5. It is the responsibility of the network provider to implement prevention measures to avoid health hazards which may be associated to radiation from the antenna(s) connected to the unit. 6. Make sure, access is restricted to qualified personnel. 7. Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. 8. Due to power dissipation, the network element may reach a very high temperature. 9. Before opening the unit, disconnect mains. 10. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 11. This unit complies with European standard EN60950. 12. Make sure the network element settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met. 13. Although the network element is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the network element’s antenna connectors for protection against atmospheric discharge. Page 8 M0121A1A_uc.doc 1 General 1.3 PREAMBLE Mikom An Andrew Company is a leading manufacturer of coverage equipment for mobile radio networks, specializing in low cost, high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage for every application: outdoor use, indoor installations, tunnels, subways and many more. Mikom has engineering and manufacturing facilities in Germany, Italy and the USA. In addition, it maintains many field engineering offices throughout the world. Mikom GmbH operates a quality management system which complies with the requirements of ISO 9001. All equipment is manufactured using only highly reliable materials. In order to ensure constant first-rate quality of the products, a comprehensive quality assurance has been conducted at all fabrication stages. Every component leaves the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal function. The declaration of conformity for the product is available on request via the local offices or from Mikom directly. Any intervention must be carried out by authorized persons only. If technical assistance for the product is required, please contact the local office or Mikom directly at one of the following addresses: Mikom GmbH An Andrew Company Industriering 10 86675 Buchdorf Germany Phone: +49 (0) 9099 69 0 Fax: +49 (0) 9099 69 930 email: WIsupport.germany@andrew.com for The Americas: Mikom US An Andrew Company Phone: +1 (919) 771-2570 email: WIsupport.us@andrew.com When set-up is performed according to this manual, the system will operate without complications for a significant length of time. ID No: 161692 PRELIMINARY Page 9 User’s Manual for Node C Network Elements 1.4 INTERNATIONAL CONTACT ADDRESSES in Australia in France in the USA 6 Stuart Street Padstow NSW 2211 Z.I. des Ebisoires 78370 Plaisir Australia France 108 Rand Park Drive Garner NC 27529 USA Phone: +61 (2) 9774-4200 Fax: +61 (2) 9774-4500 email: Phone: +33 (1)30-79-15-36 Fax: +33 (1) 30-55-55-37 email: Phone: +1 (919) 771-2570 Fax: + 1 (919) 771email: WIsupport.australia@andrew.com WIsupport.france@andrew.com WIsupport.us@andrew.com in the UK in China in Canada Guildgate House Pelican Lane Newbury RG14 1NX, Berkshire, U.K. Ground Floor, Unit F, Tower 2 1815 Ironstone Manor, # 12 The Astoria 198 Argle Street, Pickering, Ontario L1W 3W9 Mau Tau Wai, Kowloon Hongkong Canada Phone: +44 (1635) 569-695 Fax: +44 (1635) 569-463 email: Phone: +852 2778 3187 Fax: +852 2778 3187 email: Phone: +1 (905) 839-3474 Fax: +1 (905) 839-4663 email: WIsupport.uk@andrew.com WIsupport.china@andrew.com WIsupport.canada@andrew.com in Switzerland in Italy in Austria Tiergartenweg 1 4710 Balsthal Switzerland Via De Crescenzi 40 48018 Faenza Italy Weglgasse 10 2320 Schwechat Austria Phone: +41 (6238) 61260 Fax: +41 (6238) 61261 email: Phone: +39 0546 697111 Fax: +39 0546 682768 email: Phone: +43 (1) 706 – 3999 Fax: +43 (1) 706 – 39999 email: WIsupport.switzerland@andrew.com WIsupport.italia@andrew.com WIsupport.austria@andrew.com in Czech Republic U Morusi 888 530 06 Pardubice-Svitkov Czech. Republic Phone: +42 (0406) 301280 Fax: +42 (0406) 301298 email: WIsupport.czechrep@andrew.com table 1-1 List of international contact addresses Page 10 M0121A1A_uc.doc 2 Introduction 2 INTRODUCTION 2.1 PURPOSE Wireless communication systems provide a two-way information transfer (voice and data) between a base station and multiple mobiles within a given area. Environmental variables such as physical structures both man-made (buildings) and natural (mountains) attenuate signals in the transmission path, which reduce the transport signal’s strength. This attenuation leads to a reduction in quality and data rate and eventually prohibits the system’s use entirely. A Node C is specifically designed to extend coverage, enhance quality, and increase air-interface capacity. In the downlink (DL), the Node C picks up signals coming from the base station, filters them, amplifies them, and retransmits them to the mobile. In the uplink (UL), it picks up signals from the mobile, filters them, amplifies them, and retransmits them to the base station. The Node C constantly monitors the quality of the signals passing through it, while simultaneously electronically decreasing isolation requirements. 2.2 THE NODE C NETWORK ELEMENT The Node C is a primary network element, capable of enhancing up to three adjacent CDMA carriers in a CDMA system. Its primary function is to increase the signal strength between multiple mobiles and a base station in areas where basic voice or high-speed data transmission is not available. It may be used for basic coverage, signal reinforcement, and cell shaping, which can increase a network’s coverage area, data rate, and capacity. The Node C is a dedicated CDMA device. However, several enhancers operating at different frequencies and technologies may share the same hardware (cables and antennas) via a crossband coupler. Within the CDMA frequency band, multiple operators may use the same unit via additional modules, thus reducing cost, while sharing the user interface and antennas. The Node C may be set-up locally or remotely. A circuit switch or packet data modem may be connected to an integrated controller. This provides the network management system with on-demand, alarm generated, or heartbeat monitoring via the always-connected packet features. The Node C has features and functions that may be monitored and changed by the operators via a web-based browser remotely or locally, or via the SNMP based OMC software platform. The graphical interface of the Node C provides a setup menu including a setup wizard which allows both setup and monitoring capability without any equipment required apart from a laptop or PC. The Node C network element is self-diagnosing, self-adaptive, and virtually maintenance-free. ID No: 161692 PRELIMINARY Page 11 User’s Manual for Node C Network Elements 2.3 QUICK START CHECKLIST Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. Setting up the Node C is quick and easy. The following step-by-step procedure provides a quick overview for a correct setup and optimization. a. Required Equipment • Node C • donor antenna • coverage antenna(s) or DAS • coaxial feeder cable • connectors • laptop with connection and mains cable b. Required Information Make sure to have the following information at hand: • important on-site conditions (e.g. base station location, mains supply, etc.) • channels to be enhanced/amplified • pilot • pilot power to total power c. Procedure 1. Install the donor and coverage antennas. 2. Install the feeder cable from the Node C to the antennas. 3. Install the Node C (see chapter 3 Installation). 4. Install the Interface Unit (see chapter 3 Installation). 5. Connect cables between the Interface Unit and the Node C (see chapter 3.2 Electrical Installation). 6. Connect power and the antenna feeder cables to the Node C. 7. Open the Interface Unit as described in chapter 4.1 General. 8. Setup the connection computer (see chapter 4.2 Software Setup) and establish a connection to the Node C (see chapter 4.2.3 Connection Procedures). 9. Login to the unit and follow the installation wizard option for easy installation. a. Optimize the donor antenna performance (see chapter 4.2.4.1 Setup Wizard). b. Select the channels for enhancement. c. Enter the desired output power in the downlink. d. Enter the pilot power to total power ratio of the donor base station. e. Enter the relative uplink gain. f. Setup the modem (if applicable) and enter data in the other user fields. 10. The Node C setup is complete. 11. Open the “Save Configuration to Laptop” menu for record keeping purposes. 12. Unplug the computer, close the Interface Unit and tighten all screws. Page 12 M0121A1A_uc.doc 3 Installation 3 INSTALLATION 3.1 MECHANICAL INSTALLATION 3.1.1 General Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the manufacturer are not met. 2. It is recommended only to use the mounting hardware delivered by the manufacturer. If different mounting hardware is used, the specifications for stationary use of the unit must not be exceeded. ) Note: 3. Exceeding the specified load limits may cause the loss of warranty. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Due to power dissipation, the unit may reach a very high temperature. Ensure sufficient airflow for ventilation. Above and below the units a minimum distance of 300* mm to ceiling, floor, etc. has to be kept. This distance must also be observed between two units if they are mounted one above the other. This value does not apply to the distance between Interface Unit and Node C. The distance required between the two cabinets is specified in table 3-1 Mounting distance. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the unit. ) Note: Both the Node C and the Interface Unit are delivered with a premounted front cover. This cover is of vital importance for the correct forced airflow (of Node C 43) and for passive cooling (of Node C 37 and Interface Unit). Thus, do not operate the units without cover. ID No: 161692 PRELIMINARY Page 13 User’s Manual for Node C Network Elements 3.1.2 Wall Mounting Procedure • Check the wall mounting kit and the wall to determine their suitability. • The maximum distance between the Node C and the Interface Unit depends on the length of the cable bridge (standard length is 500 mm) by which they will be connected (see table 3-1 Mounting distance). Thus, before marking the mounting positions, check the length of the cable bridge and make sure to install the units at a suitable distance. Mounting style: Length of cable bridge: Maximum distance beside each other* 500 mm 800 mm 2000 mm 140 mm 400 mm 1600 mm one above the other** only 2000 mm possible 1000 mm (min.=300 mm) * Maximum distance is referring to distance between the cabinet sides ** It is recommended to install the Node C above the Interface Unit; max. distance is the distance between top of lower and bottom of upper unit table 3-1 Mounting distance ) Note: • The following figures show units that are mounted beside each other. To install one above the other proceed in the same way, also observing the specified mounting distance from table 3-1. Mark the position of the eight drilling holes (four per unit) for the Node C and Interface Unit according to figure 3-1. Please observe that the figure always shows a pair of drill holes for each position. Only drill one of each pair. figure 3-1 Positions of drilling holes Page 14 M0121A1A_uc.doc 3 Installation ) Note: • Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded. Drill eight holes (four per unit) at the marked positions and insert dowels*. The dowels are not part of the delivery (and thus not illustrated in the figure) since the suitable type depends on the on-site conditions (the material of wall). Therefore, use dowels that are appropriate for the mounting surface. • Use a cap nut or locknut to screw the eight M8 dowel screws into the dowels. • Use a hex wrench, opening 17 (old standard) or 16 (new standard), to loosen the M10 hexagon head screws (four per unit) by which the mounting brackets are fastened to the cabinet sides. • Mount the mounting brackets to the screws, and fasten them using the M8 washers, locking rings, and hex nuts that are part of the wall mounting kit. • Hang the cabinets into the brackets and fasten them with the M10 hexagon head screws*. M10 hexagon head screws Plain washer M8 Locking ring M8 Dowel screw M8 Hex nut M8 G0987Z0 figure 3-2 Wall mounting procedure * If other screws than the ones delivered by the supplier are used for fastening, these must have a diameter of at least 8 mm and an appropriate length (depending on the dowels). Additionally, make sure they are adequate for supporting a maximum weight of 50 kg per unit. For mounting both cabinets as one unit, a cabinet combining kit is available. The according mounting procedure is explained in the following chapter. ID No: 161692 PRELIMINARY Page 15 User’s Manual for Node C Network Elements 3.1.3 Connection Option • In order to mount the system using the cabinet combining kit, dismount the mounting brackets from the cabinets of the units by loosening the hexagon head screws M10x20 by which the brackets are screwed to the housing (four per unit). Do not unscrew those screws, only loosen them by approx. three turns and take off the brackets. • The two inner brackets are no longer required; exchange the outer brackets and fasten them to the cabinets (as indicated below). Bracket 1 1st st ep: Remove and discard 2nd st ep: Exchange Bracket 1 and Bracket 2; t hen mount as shown: Bracket 1 Bracket 2 Bracket 2 3rd st ep: Join unit s and mount joint syst em t o wall G0987MG figure 3-3 Connection option Washer DIN125 • Join the two cabinets using the parts of the cabinet combining kit as indicated. • Use the special mounting plan supplied as part of the cabinet combining kit for drilling the according holes and mount the system to the wall. Hexagon head screws M10x4 M10 nut s Connect ing plat e Bracket s G0987MG figure 3-4 Cabinet combining kit Page 16 M0121A1A_uc.doc 3 Installation 3.1.4 Pole Mounting Procedures The following figure illustrates the two pole mounting options: back-to-back (left) and two systems (right). figure 3-5 Pole mounted systems • Before starting the mounting procedure, check the pole diameter of the pole to which the units will be installed; then, cut the thread-bolts (see table 3-3 Components of pole mounting kits, pos. 5) to the required length according to the following table, which also states the appropriate cable bridge lengths: Pole-diameter 100 110 120 130 140 150 160 170 180 190 200 (mm) Length of Thread216 226 236 246 256 266 276 286 296 306 317 Bolt (mm) Length of cable bridge (mm) 800 2000 (back-to-back) Length of cable bridge (mm) 800 2000 (for 2 systems) table 3-2 Required length of thread-bolts and cable bridge ID No: 161692 PRELIMINARY Page 17 User’s Manual for Node C Network Elements Both types of pole mounting kit consist of the following parts (in different quantities): No Part Pole mounting brace Washer DIN 9021 – 8.4 Nut M8 DIN 934 Spring ring DIN 127 – A8 No Part Thread-bolt M8 Washer M8 DIN 125 Hexagon head screw M8 Fastener table 3-3 Components of pole mounting kits The numbers in the above table refer to the numbering of the components in the following figures. Positions 7 and 8 are only required for mounting two systems. figure 3-6 Back-to-back pole mounting • Dismount the mounting brackets from the cabinets of the units by loosening the hexagon head screws M10x20 by which the brackets are screwed to the housing (four per unit). Do not unscrew those screws, only loosen them by approx. three turns and take off the brackets. • Fasten the mounting brackets to the pole using the corresponding mounting kit as illustrated in figure 3-7 Pole mounting two systems or figure 3-6 Back-to-back pole mounting, respectively. Page 18 M0121A1A_uc.doc 3 Installation • In case of two systems (figure 3-7) first mount the mounting brackets of the Node C units; then adjust and mount the fasteners (no. 8) accordingly before fastening the mounting brackets of the Interface Units to the fasteners. • Hang the units into the respective mounting brackets and fasten the hexagon head screws M10x20. figure 3-7 Pole mounting two systems ID No: 161692 PRELIMINARY Page 19 User’s Manual for Node C Network Elements 3.2 ELECTRICAL INSTALLATION 3.2.1 General Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed. 2. It is compulsory to ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground bonding cable. 3. Although the unit is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the unit’s antenna connectors for protection against atmospheric discharge. In areas with strong lightning it is strongly recommended to insert additional lightning protection. 4. Hard wired installation of mains supply for the unit requires an easily accessible separation device in the mains circuit. 5. Make sure that an appropriate circuit breaker and an overcurrent limiting device are connected between mains and the unit. 6. A connection of mains supply to a power socket requires the power socket to be nearby the unit. 7. The unit might be supplied from IT mains. (The maximum nominal line to line voltage must not exceed 400VAC). 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6V (see electrochemical contact series). 10. It is sufficient to tighten the 7/16 or N antenna connector hand-screwed. Any use of a tool (e.g. pair of pliers) might cause damage to the connector and thus lead to malfunctioning of the unit. 11. For unstabilized electric networks which frequently generate spikes, it is advised to use a voltage limiting device. 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection), however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection) depending on the individual application in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting any cables. Page 20 M0121A1A_uc.doc 3 Installation 3.2.2 Grounding Grounding the Node C and Interface Unit is mandatory. Connect an earth bonding cable to the grounding connections provided at the cabinets of both the Node C and Interface Unit according to the following illustrations. Do not use the grounding connections to connect external devices. Cable bridge connectors Node C cabinet Cabinet of Interface Unit figure 3-8 Grounding bolts figure 3-9 Grounding a system The PE cables must have a minimum cross section of 10mm2. ID No: 161692 PRELIMINARY Page 21 User’s Manual for Node C Network Elements 3.2.3 Power Connection Before connecting electrical power to the units, the system must be grounded as described in the previous chapter. Mains power must be connected at the mains connector of the Interface Unit. The power supply plug is included with the Node C. The correct wiring of the power supply plug is as follows: Mains figure 3-10 Power supply plug figure 3-11 Mains connector A minimum cross section of 1.5 mm2 is required for the power supply connection. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. ) Note: Do not connect or disconnect the power cord at the mains connector while power is on. Turn off mains* power before connecting the power cord at the Interface Unit, then, engage mains again. * Mains power must be interrupted with an external AC breaker. For the AC breaker, observe the following recommendation: 120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50/60 Hz AC service is needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240-Volt service. Page 22 M0121A1A_uc.doc 3 Installation 3.2.4 Connection of the Antenna Cables The Node C’s antenna connectors are 7/16 female equipped with an N female adapter. All connectors are located at the bottom of the cabinet. An operator should refer to the documentation of the cable connector manufacturer for best mating procedures. Furthermore, the bending radius of the antenna cables should be maintained at all times. There are several issues to be considered when selecting the cable and antenna types. • Smaller diameter cables are less expensive and easier to install but have worse performance. • Highly directional antennas with good front-back-ratios (40 dB is typical) are recommended because they improve isolation and cell site selectivity. Tighten the 7/16 or N connectors ONLY by hand. The use of pliers may cause damage to the connector and impair the performance of the Node C. Diversity Primary Coverage antenna (to mobile) Donor antenna (to base station) figure 3-12 Front view of antenna connections 3.2.5 Connection of Cable Bridge The Interface Unit and the Node C are connected via a cable bridge. The bridge ports 12V, 28V, ground, USB, and RS232 between the two units as well as the general alarming and signalling. It is also the interconnection and intercommunication bus between the units. ID No: 161692 PRELIMINARY Page 23 User’s Manual for Node C Network Elements The cable bridge connectors are located at the bottom of the Node C and Interface Unit. Cable bridge connector Antenna connnectors figure 3-13 Connector panel of the Node C Antenna connector for modem (operating in different network) Cable glands for external alarms, summary alarm & PSTN Cable bridge connector Mains power connectors figure 3-14 Connector panel of the Interface Unit 3.2.6 Connections for Optional Equipment The Interface Unit connector panel has ports for external equipment, such as a modem operating in a different network and external alarms. These connectors may be used entirely at the operator’s discretion. Page 24 M0121A1A_uc.doc 4 Commissioning 4 COMMISSIONING 4.1 GENERAL Read the health and safety warnings in chapter 1.2 Health and Safety Warnings and observe the following step-by-step procedure. • Do not operate the Node C without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load. • Only qualified personnel should carry out the electrical, mechanical, commissioning, and maintenance activities that require the unit to be powered on when open. • When opening the Node C or interface box do not damage the warranty labels on the internal devices. The warranty is void if the seals are broken. To open the cabinet of the Interface Unit, first remove the front cover plate by loosening the four M5 socket head cap screws (circle-marked in figure to the left). Do not remove those screws. When they are loosened, the front cover plate can be taken off. To open the housing, unscrew the three M5 socket head cap screws (captive) of the top cover of the Interface Unit. Three top cover screws ) Note: Do not forget to reinstall the front cover afterwards to ensure safe operation. Note: Before closing the Interface Unit, make sure that the mains power switch inside is set to On: Mains power switch figure 4-1 Front and top cover screws ID No: 161692 figure 4-2 Position of mains power switch PRELIMINARY Page 25 User’s Manual for Node C Network Elements 4.2 SOFTWARE SETUP 4.2.1 Remote Control For remote control and/or supervision of the Node C the following services are provided: • An OMC-type software platform (see separate manual) • SMS alarm-forwarding (for details see chapter 5.2.5 Alarmforwarding) • Web page (see chapter 4.2.4 and online-help) 4.2.2 Connection Devices To connect to the Node C, the following devices are available: • Locally, via the RS232 interface of the distribution & alarm board of the Interface Unit (see figure 5-15) using either the connected USB cable or the null modem cable which is part of the delivery for the connection of a PC or laptop. • Remotely, if the optional modem is installed in the Interface Unit. All local commands may be issued via the web interface over the remote modem. 4.2.3 Connection Procedures 4.2.3.1 Setup Overview Four steps are required to set up a connection to the Node C. 1. Install the USB to serial adapter in the computer. The USB adapter is part of the delivery and is already connected to the RS232 connector of the distribution & alarm board (see figure 4-3). For the first connection, install the correct driver from the CD (see chapter 4.2.3.2 Installing the USB driver). For the connection via null modem cable, disconnect the USB connector from the RS232 connector (see figure 4-3) and connect the null modem cable. 2. Configure the connection device, i.e. RS232/USB/modem. (See section a) of chapter 4.2.3.3, 4.2.3.4, or 4.2.3.5 depending on the operating system.) 3. Setup a connection: a) Direct connection via PC or laptop: similar to connecting a computer to a standard Internet service provider (ISP); see section b) of chapter 4.2.3.3 or 4.2.3.5 depending on the operating system. b) Modem connection; see section b) of chapter 4.2.3.4. 4. Establish the connection; see section c) of chapter 4.2.3.3, 4.2.3.4, or 4.2.3.5 depending on the operating system. The following instructions are for Windows XP and Windows 2000. This procedure must be done only once with the first setup. Page 26 M0121A1A_uc.doc 4 Commissioning 4.2.3.2 Installing the USB driver The USB adapter and the driver CD are located inside the Interface Unit: Driver CD USB adapter with USB cable Position of optional modem RS232 connector for USB or null modem cable connection figure 4-3 USB and null modem cable connection When the USB adapter is connected to a PC for the first time, the USB driver must be installed. The Node C and Interface Unit must be switched on for the procedure. To install the driver, proceed as follows: • Connect the USB cable of the USB adapter to the USB port of the PC. • Then, wait until the system (valid from Windows98ME) delivers the message that a new USB device was found and asks for the driver. • Put the CD into the CD-ROM drive of the PC and the system will ask how to search for the driver. • Select the automatic search (usually default), confirm, and wait while the system searches for the driver. • The successful installation will be informed by a message that the new hardware was successfully installed. • After confirming this message the CD can be taken out of the drive and put back into the plastic cover inside the Interface Unit. • Reboot the PC. When the connection is made the next time, this procedure is no longer necessary. ID No: 161692 PRELIMINARY Page 27 User’s Manual for Node C Network Elements 4.2.3.3 Direct connection for Windows XP a) Setting up the device for the direct connection 1. To start the Phone and Modem Options, choose Start→Control Panel→Phone and Modem Options. 2. Select the Modems tab and click the Add... button. 3. Choose to select from a list. Click Next. Page 28 M0121A1A_uc.doc 4 Commissioning 4. For a direct connection choose the Communication cable between two computers as device. Click Next. 5. Select your port (usually COM1 for a direct connection), continue with Next, and in the next window click Finish. ID No: 161692 PRELIMINARY Page 29 User’s Manual for Node C Network Elements b) Setting up a direct connection 1. Choose Start→Control Panel→Network Connections→New Connection Wizard. 2. The first page is the Welcome window: Continue with Next. 3. In the Network Connection Type window, select Set up an advanced connection. Click Next. Page 30 M0121A1A_uc.doc 4 Commissioning 4. In the Advanced Connection Options, choose Connect directly to another computer. Click Next. 5. In the next window choose Guest. Click Next. 6. Next, enter a name for the new connection. Click Next. ID No: 161692 PRELIMINARY Page 31 User’s Manual for Node C Network Elements 7. The next window is Select a Device. This window will provide a drop-down list of known communication ports (devices) to choose from. Choose a serial port. If the RS232 is used, this port is most likely (COM1). If a USB port is used some other COM port number should be used. In such a case, take care that the USB driver is installed and connected before completing this selection or the connection will not work. Click Next. 8. The next window is Connection Availability. Choose My use only. Click Next. 9. In the window Completing the New Connection Wizard, choose whether to add a shortcut to the desktop. Click Finish Page 32 M0121A1A_uc.doc 4 Commissioning 10. In the Connection window, enter User name and Password. Select to Save user name and password ... for Me only.. Enter: User name:Password: Click Properties. 11. Under the General tab ensure the correct device is selected. Click Configure, and in the Modem Configuration window, choose 57600 for Maximum speed. No other box should be checked. Click OK. 12. Select the Options tab and make sure that all dialling options except the last one (Include Windows logon domain) are checked. Set the redialling options as required and click OK. ID No: 161692 PRELIMINARY Page 33 User’s Manual for Node C Network Elements 13. Select the Security tab, select Advanced (custom settings), and click Settings. 14. Only allow Challenge Handshake Authentication Protocol (CHAP) Microsoft CHAP (MS-CHAP) and Microsoft CHAP Version 2 (MS-CHAP v2) protocols. Click OK. 15. Click Typical and choose Require secured password. Click OK. Page 34 M0121A1A_uc.doc 4 Commissioning 16. Select the Networking tab and click the Settings button. There are 3 PPP settings. Make sure they are all OFF and click OK. 17. In the Networking window, highlight the Internet Protocol (TCP/IP) component and click the Properties tab. 18. Obtain an IP address automatically and Obtain DNS server address automatically must be checked. Click Advanced. ID No: 161692 PRELIMINARY Page 35 User’s Manual for Node C Network Elements 19. In the General tab, uncheck all boxes. In the DNS tab, make sure Append primary and Append parent and Register this connection are checked. In the WINS tab, make sure Enable LMHOSTS lookup is checked. Click OK. 20. For Internet Connection Firewall and Internet Connection Sharing settings, select the Advanced tab. Click OK to get back to the Connect window. 21. The connection procedure is described in the following. If the connection is to be made directly from the Connect window, step one of the following description can be skipped. Page 36 M0121A1A_uc.doc 4 Commissioning c) Establishing the connection 1. Choose Start→Control Panel→Network Connections→ (i.e. in this example “DCM_Local”). The properties of this connection should already have been setup. 2. Enter in the User name field. Enter in the Password field. Select to Save this user name and password ... for Me only. Click Connect . While the connection is established the following window is displayed When the connection is successful an icon will appear in the system tray. This icon will “light up” to indicate network activity between the computer and the Node C. To check the status of the connection, click on the icon. Please continue with chapter 4.2.3.6 Accessing the web page . ID No: 161692 PRELIMINARY Page 37 User’s Manual for Node C Network Elements 4.2.3.4 Modem connection for Windows XP a) Setting up the device for the modem connection 1. To start the Phone and Modem Options, choose Start→Control Panel→Phone and Modem Options. 2. Select the Modems tab and click the Add... button. 3. Choose to select from a list. Click Next. Page 38 M0121A1A_uc.doc 4 Commissioning 4. For a modem connection, choose the Standard 19200 bps Modem as device. Click Next. 5. Select your port (usually COM2 for a modem connection), continue with Next, and in the next window click Finish. ID No: 161692 PRELIMINARY Page 39 User’s Manual for Node C Network Elements b) Setting up a modem connection 1. To start, choose Start→Control Connection Wizard. Panel→Network Connections→New 2. The first window is the Welcome window: Continue with Next. 3. In the Network Connection Type window, select Connect to the network at my workplace. Click Next. Page 40 M0121A1A_uc.doc 4 Commissioning 4. In the Network Connection window, choose Dial-up connection. Click Next. 5. Select the Standard 19200 bps Modem as device. Click Next. 6. Next, enter a name for the new connection. ID No: 161692 PRELIMINARY Page 41 User’s Manual for Node C Network Elements 7. In the next window enter the phone number of the modem that is installed in the Node C. Click Next. 8. The next window is Connection Availability. Choose My use only. Click Next. 9. In the window Completing the New Connection Wizard, choose whether to add a shortcut to the desktop. Click Finish Page 42 M0121A1A_uc.doc 4 Commissioning 10. In the Connection window, enter username and password. Select to Save user name and password ... for Me only. Enter: User name: Password: Click Properties. 11. Under the General tab ensure the correct device is selected. Click Configure, and in the Modem Configuration window, choose 19200 for Maximum speed. No other box should be checked. Click OK. 12. Select the Options tab and make sure that all dialling options except Include Windows logon domain are checked. Set the redialling options as required and click OK. ID No: 161692 PRELIMINARY Page 43 User’s Manual for Node C Network Elements 13. Select the Security tab, select Advanced (custom settings), and click Settings. 14. Only allow Challenge Handshake Authentication Protocol (CHAP) Challenge Handshake Authentication Protocol (CHAP) Microsoft CHAP (MS-CHAP) and Microsoft CHAP Version 2 (MS-CHAP v2) protocols. Click OK. 15. Click Typical and choose Require secured password. Click OK. Page 44 M0121A1A_uc.doc 4 Commissioning 16. Select the Networking tab and click the Settings button. There are 3 PPP settings. Make sure they are all OFF and click OK. 17. In the Networking window, highlight the Internet Protocol (TCP/IP) component and click the Properties tab. 18. Obtain an IP address automatically and Obtain DNS server address automatically must be checked. Click Advanced. ID No: 161692 PRELIMINARY Page 45 User’s Manual for Node C Network Elements 19. In the General tab, uncheck all boxes. In the DNS tab, make sure Append primary and Append parent and Register this connection are checked. In the WINS tab, make sure Enable LMHOSTS lookup is checked. Click OK. 20. For Internet Connection Firewall and Internet Connection Sharing settings, select the Advanced tab. Click OK to get back to the Connect window. 21. The connection procedure is described in the following. If the connection is to be made directly from the Connect window, step one of the following description can be skipped. Page 46 M0121A1A_uc.doc 4 Commissioning c) Establishing the connection 1. Choose Start→Control Panel→Network Connections→ (i.e. in this example “DCM_via_Modem”). The properties of this connection should already have been setup. 2. Enter the term “username” in the User name field and the term “password” in the Password field as shown below. Select to Save this user name and password ... for Me only. Click Connect. While the connection is established the following window is displayed: When the connection is successful an icon will appear in the system tray. This icon will “light up” to indicate network activity between the computer and the Node C. To check the status of the connection, click on the icon. Please continue with chapter 4.2.3.6 Accessing the web page. ID No: 161692 PRELIMINARY Page 47 User’s Manual for Node C Network Elements 4.2.3.5 Direct connection for Windows 2000 a) Setting up the device for the direct connection 1. To start the Phone and Modem Options, click Start→Settings→Control Panel→Phone and Modem Options. 2. Click the Modems tab and choose Add... . 3. Choose to select from a list, click Next. Page 48 M0121A1A_uc.doc 4 Commissioning 4. Select your port, continue with Next, and in the next window click Finish. 5. Highlight the port associated with the direct connection of the RS232 or USB port. Click Properties. ID No: 161692 PRELIMINARY Page 49 User’s Manual for Node C Network Elements 6. In the General tab, change the port speed to 57600. Click the Advanced tab. Click the Change Default Preferences tab. 7. Set the Port speed to 57600 and the Flow control to None. Click the Advanced tab. Set Data bits to 8. Set Parity to None. Set Stop bits to 1. 8. Click OK several times to exit all the windows. The modem configuration is now complete. Page 50 M0121A1A_uc.doc 4 Commissioning b) Setting up a direct connection 1. Start the Network Connection Wizard. Click Start→Settings→Network and Dial-up Connections →Make New Connection. 2. The first window is the Welcome window as shown below. Click Next. 3. The next window is Network Connection Type. Select Connect directly to another computer. Click Next. ID No: 161692 PRELIMINARY Page 51 User’s Manual for Node C Network Elements 4. The next window is Host or Guest. Choose Guest. Click Next. 5. The next window is Select a Device. This window will provide a drop-down list of known communication ports (devices) to choose from. Choose a serial port. If the RS232 is used, this port is most likely (COM1). If a USB port is used some other COM port number should be used. Take care that the USB driver is installed and connected before completing this selection or the connection will not work. Click Next. 6. The next window is Connection Availability. Choose Only for myself. Click Next. Page 52 M0121A1A_uc.doc 4 Commissioning 7. The next window is the Complete the Network Connection Wizard. Enter Node C as the name for the connection. Click Finish. 8. The next window is the Connection window Enter in the User Name field. Enter in the Password field. Check Save Password. Click Properties. 9. Under the General tab ensure the correct device is selected. Click Configure. ID No: 161692 PRELIMINARY Page 53 User’s Manual for Node C Network Elements 10. Choose 57600 for Maximum speed. All other boxes should not be checked. Click OK. 11. Click the Security tab. Click Advanced (custom settings). Click Settings. Page 54 M0121A1A_uc.doc 4 Commissioning 12. Make sure Challenge Handshake Authentication Protocol (CHAP) Microsoft CHAP (MS-CHAP) Microsoft CHAP Version 2 (MS-CHAP v2) are checked and all the rest of the boxes are NOT checked. Click OK. 13. Click Typical and choose Require secured password. ID No: 161692 PRELIMINARY Page 55 User’s Manual for Node C Network Elements 14. Click the Networking tab. Click the Settings button. There are 3 PPP settings. Make sure they are all OFF. Click OK on the PPP Setting window. 15. Highlight the Internet Protocol (TCP/IP) component. Click the Properties tab. Click Obtain an IP address automatically. Click Obtain DNS server address automatically Click Advanced. Page 56 M0121A1A_uc.doc 4 Commissioning 16. In the General tab, uncheck all boxes. In the DNS tab, make sure Append primary and Append parent and Register this connection are checked. 17. Click the WINS tab. Make sure Enable LMHOSTS lookup is checked. Click the Options tab. Click Properties. ID No: 161692 PRELIMINARY Page 57 User’s Manual for Node C Network Elements 18. Click Do not use IPSEC. Click OK. Returning to the Options tab click OK and return back to the main window. 19. Click the Sharing tab. Make sure that Shared access is OFF. Click OK. Page 58 M0121A1A_uc.doc 4 Commissioning c) Establishing the connection 1. Click Start→Settings→Network and Dial-up Connections→Node C. The properties of this connection should already have been setup. Enter in the User Name field. Enter in the Password field. Check Save Password. Click Connect and the following connection windows will appear. 2. When the connection is successful an icon will appear in the system tray. This icon will “light up” to indicate network activity between the computer and the Node C. To check the status of the connection, click on the icon. 3. Please continue with chapter 4.2.3.6 Accessing the web page. ID No: 161692 PRELIMINARY Page 59 User’s Manual for Node C Network Elements 4.2.3.6 Accessing the web page 1. Open Internet Explorer and enter the address: 1.2.1.1. Enter in the User Name field. Enter in the Password field. Note that these fields are case-sensitive. 2. After the login, the home page will appear. From this page the entire Node C may be controlled. The most important menus will be explained in the following chapter. For any further details click the Help button (also available in all of the menus), to open the online help screens. Help button figure 4-4 Home page of web interface The next chapter contains an explanation of the most important menus. Page 60 M0121A1A_uc.doc 4 Commissioning 4.2.4 Main Menus of the Web Page For detailed information about a menu click the “Help” button to open the online help. 4.2.4.1 Setup Wizard This menu serves to align the donor antenna and provides overviews of all channels on air as wells as channel assignment. figure 4-5 Setup Wizard Antenna Alignment Assistant: The intent of these web pages is to help the user correctly orient the antenna by displaying the total received power in the selected 5MHz band and the power of the strongest pilots within the 5MHz channel. a) To start the Antenna Alignment Assistant (AAA): 1. 2. 3. 4. 5. Select ‘Setup Wizard‘ from the main page. Select ‘Antenna Alignment Assistant‘. Select the desired 5 MHz channel by using the dropdown box. Select ‘Start Alignment’. Observe the Rx DL Power and Pilot RSCP measurements and orient the antenna to maximize performance. 6. Click ‘Home’ when completed. ID No: 161692 PRELIMINARY Page 61 User’s Manual for Node C Network Elements b) Typical Tuning Procedure (See example table below): 1. Point the donor antenna in the general direction of the donor base station. 2. Start the AAA. 3. Verify that the reported DL Rx Power is above –90dBm. If not, orient the antenna until the signal is above –90dBm. 4. Wait for Pilot RSCP results to be reported (indicating that a valid pilot has been found). 5. Verify that the ARFCN and frequency reported at the top of the table matches the ARFCN and frequency of the donor base station. 6. Orient the antenna to maximize the Pilot RSCP from the donor base station. Usually, the best method is to course-tune the antenna based on DL Rx Power measurements and then fine-tune based on Pilot RSCP measurements. However, if multiple pilots are present, then using the DL Rx Power measurements alone may not work well, and the user will have to rely on Pilot RSCP only. 7. If multiple rays are present, then it is usually best to orient the antenna to maximize the level of the first ray (the line-of-sight – or LOS – signal). However, if the first ray is not the strongest signal, then there is an obstruction in the LOS signal, and the strongest signal is a multipath component. This may mean that the donor signal is prone to fluctuation, resulting in sub-optimal performance of the unit. DL Rx Power (dBm) Multipath Componen -80 -80 -80 -80 -80 -80 -80 -80 -80 -80 -80 -80 -80 -80 -80 Assisted Antenna Tuning Channel 12345 , 2100 MHz RSCP of RSCP of RSCP of Pilot 333 Pilot 111 Pilot 111 (dBm) (dBm) (dBm) RSCP of Pilot 444 (dBm) 1st Ray 2nd Ray 1st Ray 1st Ray -91 -91 -90 -90 -92 -92 -91 -91 -93 -93 -92 -92 -94 -94 -93 -93 table 4-1 Assisted antenna tuning Page 62 M0121A1A_uc.doc 4 Commissioning c) Notes on the AAA Measurement Results: 1. The DL RX Power is the total power in the selected 5 MHz channel. The DL Rx Power measurement is updated approximately once per second. 2. The Pilot Received Signal Code Power (RSCP) measurements are updated approximately once every four seconds after the antenna assistant finds a valid pilot channel within the selected 5MHz bandwidth. It may take up to one minute to perform the initial scan and report Pilot RSCP results. 3. The most recent results are displayed in the first row, and previous results move down one row in the table. 4. Data is columnized based on the most recent pilot measurement results. 5. The pilot measurements display up to the four strongest rays. The measurement result could show one pilot with four rays, two pilots with two rays each, one pilot with three rays and one pilot with one ray, or four pilots with one ray each (or fewest results if no additional pilots are found). 6. Multiple rays of the same pilot will be shown if the weaker rays are within 10dB of the strongest ray. 7. The Pilot RSCP data is sorted based on the total power of all multipaths for each particular scramble code. For instance, if one pilot has two rays, each at –63dBm (for a total power of -60 dBm), they will be listed first if all other pilots are less than -60 dBm. 8. If two or more multipath signals are received, then the power of each ray will be displayed in order of arrival. The first ray is the line of sight signal and should be the strongest. However, it is possible for the later rays to be stronger. 4.2.4.2 Connectivity and Upload This page serves to upload new software (press the Upload Software button and follow the instructions) and for entering the modem settings for OMC communication. figure 4-6 Connectivity and Upload menu ID No: 161692 PRELIMINARY Page 63 User’s Manual for Node C Network Elements 4.2.4.3 Technician Setup figure 4-7 Technician Setup menu Description Explanation Filter Selection Select the frequency range for channel 1, 2 and 3; for filter setting refer to chapter 5.2.1 Filters. Filter Power to Total Power Ratio Enter ratio of pilot power to total power (depending on base station). Downlink Power Downlink Gain Select Power mode or Gain mode and set the desired power or gain, respectively. Relative Uplink Gain Absolute Uplink Gain Select Relative or Absolute Uplink Gain mode and set the respective value. Downlink DCM path Uplink DCM path * Downlink PA Uplink PA Complete Network Element Interference Cancellation Enable or disable the respective feature. * In the Uplink DCM path it is possible to enable or disable the primary and diversity paths individually. Page 64 M0121A1A_uc.doc 4 Commissioning 4.2.4.4 Alarm Management figure 4-8 Alarm Management menu Column Description 1 ID Clicking any of the number buttons opens a submenu * for the respective component/feature. 2 Module All components and features listed in this column can be monitored via software. Current Status The cell colour (see [4] below) indicates whether an alarm is active. If more alarms of different severity levels are active simultaneously (number of alarms is displayed in column “Alarm Count” to the right), the cell will always show the highest level that is active. This row illustrates the colours by which the individual severity levels are represented in column 3. * This submenu includes an overview of the alarms available for the respective component/feature and alarms can be disabled. In the column “Alarm Group” the severity level for each alarm can be set. The possible severity levels are illustrated under [4]. In the submenu for “VSWR, ALC, RSSI” [7] it is also possible to set the alarm threshold (level at which an alarm will released) for these features. Use the submenu [8] for “External, Fan and Door” for naming the external alarms. ID No: 161692 PRELIMINARY Page 65 User’s Manual for Node C Network Elements 4.3 TROUBLESHOOTING Connection Problem: After clicking Connect, the progression goes from Dialling to a Connection Error as shown below. Possible Solutions: I. The connection is not configured properly. a. Click Properties→Configure in the Direct Connection window. Make sure Speed is set at 57600. Make sure no flow control is checked. b. Click Start→Settings→Control Panel→ Phone and Modem Options. Go to the Modem tab. Highlight the used modem connection. Click Properties. In the General tab set the Speed to 57600. c. Click Advanced. Click Change Default Preferences. Click on the General tab. Make sure Speed is set to 57600. Make sure Flow Control is set to None. d. Click Change Default Preferences Make sure Data Bits are set to 8. Make sure Parity is set to None. Make sure Stop Bits is set to 1. Click OK to exit. II. The physical connection is loose. Page 66 M0121A1A_uc.doc 4 Commissioning Connection Problem: After entering the Node C address, an HTTP error page is returned instead of the login page. Possible Solution: I. If the computer is connected to another network, the HTTP request may be going out to that network instead of to the Node C. This is likely if after entering the Node C address, the Direction Connection icon does not light up with activity. a. Click Start→Run Type cmd to get a dos prompt. Type ipconfig /all b. To release the LAN Type Click ipconfig /release. c. Click the Direct Connection icon Click Disconnect. d. Close Internet Explorer. e. Restart the connection procedure. ID No: 161692 PRELIMINARY Page 67 User’s Manual for Node C Network Elements For your notes: Page 68 M0121A1A_uc.doc 5 Functional Description 5 FUNCTIONAL DESCRIPTION 5.1 GENERAL The following figure shows the DC block diagram of the Node C. figure 5-1 DC block diagram of a Node C ID No: 161692 PRELIMINARY Page 69 User’s Manual for Node C Network Elements The following figure shows the RF block diagram of the Node C. figure 5-2 Configuration of a Node C network element The Node C is designed to amplify signals between multiple mobiles and a base station in a CDMA system. The unit consists of a filter and amplifier chain in the downlink and one or two filters and amplifier chains in the uplink (primary and diversity). The uplink and downlink paths are connected via a duplexer on both ends of each path. Page 70 M0121A1A_uc.doc 5 Functional Description In the primary uplink path, a signal originating from the mobile is separated from the downlink signal via the primary UL IN duplexer. It is then amplified by an integrated low noise amplifier (LNA) and forwarded to the uplink digital channel module (DCM). The DCM down-converts the signal to base-band, digitally filters it, amplifies it and then up-converts it. In addition the interference cancellation technology is implemented in the DCM. Finally, the signal is sent to the final amplifier and combined with the downlink input signal in the DL IN duplexer. The optional diversity uplink path (via a second filter) is identical except signals enter via the diversity UL IN duplexer and are combined in the DCM with the primary path. In the downlink path, a signal originating from the base station is separated from the uplink signal in the DL IN duplexer. It is then amplified by an integrated low noise amplifier (LNA) and forwarded to the downlink digital channel module (DCM). The DCM down-converts the signal to base-band, digitally filters it amplifies it and then up-converts it. In addition the interference cancellation technology is implemented in the DCM. Finally, the signal is sent to the final amplifier and combined with the uplink input signal in the primary UL IN duplexer. The downlink DCM is also responsible for communication and control of the entire unit. Using a Node C 1943 as an example, the following figure illustrates the positions of the RF components inside the Node C. figure 5-3 RF path of a Node C, exemplary ID No: 161692 PRELIMINARY Page 71 User’s Manual for Node C Network Elements 5.2 FEATURES OF THE NODE C 5.2.1 Filters Filters are set automatically according to the channels set in “Setup Wizard” or “Technician Setup”. For further information about these menus refer to chapters 4.2.4.1 and 4.2.4.3. Possible filters are: 10 One WCDMA channel 15 two adjacent WCDMA channels MHz and three adjacent WCDMA channels two WCDMA channels; intermediate channel not used 5.2.2 Digital ICE (Digital Interference Cancellation Equipment) Digital ICE has been developed to enhance antenna isolation. This feature enables the Node C to provide coverage in areas where effectivity is decreased due to physical site limitations which cause insufficient antenna isolation. Antenna isolation is the RF loss measured between the donor antenna and the coverage antenna. If the gain of the network element exceeds the path loss, feedback in form of oscillation occurs. The isolation is usually dominated by the direct path loss from one antenna to the other, but reflections can contribute to or even affect antenna isolation. Digital ICE cancels the signal from the primary feedback path, thus allowing the gain of the network element to be increased. The required delay resulting from the on-site conditions is measured by the DCM module and set accordingly. For software setting commands please refer to the online help screens. The Digital ICE function can be enabled or disabled in the “Technician Setup” page (see chapter 4.2.4.3). Isolation and gain margin* can be checked in the “Status and Reports” menu accessible via the home page of the web interface (see figure 4-4). * gain margin = antenna isolation minus Node C gain Page 72 M0121A1A_uc.doc 5 Functional Description 5.2.3 VSWR (Voltage Standing Wave Ratio) This feature enables the provider to query the status of the antenna system (antenna & cable). The voltage standing wave ratio of the DL output antenna port is measured. If the VSWR falls below the value set in the “Alarming Management” (see chapter 4.2.4.4), an alarm is released. The alarm can be forwarded to the OMC where the faults and irregularities can be acknowledged and eliminated promptly. The current VSWR value can be checked in the “Status and Reports” menu accessible via the home page of the web interface (see figure 4-4). 5.2.4 RSSI (Receive Signal Strength Indication) The RSSI provides controlling and monitoring of the receive level of a base station (DL RSSI) or user equipment (UL RSSI) to a Node C. It measures the level of the input signal by detecting the RF and converting the analogue level into a digital value. The data are processed and evaluated by software. An alarm will be released if the measured signal level exceeds the alarm level set by the provider via software. ) Note: If the Node C is equipped with a diversity path, both values will be combined before the RSSI evaluation. Thus, only one UL value is reported. The current RSSI values can be checked in the “Status and Reports” menu accessible via the home page of the web interface (see figure 4-4). 5.2.5 Alarmforwarding Alarms can be forwarded to a defined phone number or to the OMC if the Node C is equipped with a modem or a mobile station. This enables the provider to control and to query the status of the network. Faults and irregularities can be recognized and eliminated. With an optional modem the Node C also provides an SMS feature, by which the unit is able to send out alarm messages as SMS. For further details please contact your supplier. ID No: 161692 PRELIMINARY Page 73 User’s Manual for Node C Network Elements 5.2.6 External Alarms The external alarms are used to monitor the status of one or more external devices via the Node C. A UPS or entry alarm is among the items that might be connected to the contact relay and monitored via the Node C. The cage clamp connectors are located on the distribution & alarm board of the Interface Unit. Observe that the cross-sectional area of the wires to be connected must be in the range from 0.5 - 1.0 mm2. Do not use wire-end sleeves (wire cable ends). figure 5-4 Configuration of external alarm clamps There are three external cage glands at the bottom of the Interface Unit, which may be used to connect the external devices. All external alarms are defaulted to high (5VDC) without connection. This setting may be changed on the external alarm page to active high or active low. The severity levels of the external alarms may be set via the web page. More information about the external alarm settings is available in the web page and online-help. When not all of the external alarms are required, make sure that the other alarms are set to active low or disable the alarm; otherwise the status will always show an alarm. The names for each external alarm are user-definable on the external alarm page (see chapter 4.2.4.4 Alarm Management) and it is suggested that they be renamed to indicate the use of these alarms. Input voltage range Recommended input line Nominal sink current to ground Active level Connectors Page 74 5VDC Potential free 15mA High or low set via software Cage clamps M0121A1A_uc.doc 5 Functional Description 5.2.7 Summary Alarm The summary alarm is a DC insulated contact relay. Observe that the cross-sectional area of the wires to be connected must be in the range from 0.14 - 1.5 mm2. Summary alarm relay contact figure 5-5 Summary alarm relay The following table indicates the three-connector pin out. Pin No. ID No: 161692 Contact Normally closed Common Normally open Maximum Resistive Load Max 1A @ 50VDC Max 2A @ 30VDC Max 1A @ 230VAC PRELIMINARY Page 75 User’s Manual for Node C Network Elements 5.3 COMPONENTS OF THE NODE C AND INTERFACE UNIT The actual configuration can be seen at the configuration list*, which is part of the delivery. The following figure shows a Node C 1943** (layout of Node C 843 is the same) and an Interface Unit with PSU redundancy option (two power supplies). To be replaced by an electronic door label that will be accessible via software & remote control. ** The layout of a Node C x37 differs from the Node C x43 only in the design of the DL final amplifier (see chapter 5.3.5 Downlink Final Amplifier). Final amplifiers DL UL DCM modules UL Power supplies (right: optional) DL RF and DC Distribution Unit Duplexers CD for USB driver Distribution and interface board Position of optional modem figure 5-6 Layout of a Node C 1943 and Interface Unit 5.3.1 Duplexer The duplexer is used to isolate the uplink from the downlink, i.e. to separate the transmitting path from the receiving path. The pass band of the duplexer is the full 60 MHz of the CDMA band. This allows the same Node C to be used regardless of its operator’s frequency plan. The integrated LNAs (low noise amplifiers) are biased via the RF cable from the DCM module. The DL/LNA can be bypassed for strong input signals by the DCM module automatically. Page 76 M0121A1A_uc.doc 5 Functional Description The DL duplexer has multiple outputs, including the primary and extension path, plus forward and reverse probes used for auto setup, VSWR, and RSSI functions. LNA figure 5-7 Duplexer, DL IN The UL IN duplexer of the Node C is equipped with a diversity filter. The duplexer is used for the primary uplink path and is shared with the downlink output. LNA figure 5-8 Duplexer, UL IN, with integrated diversity filter The diversity filter is equipped to provide increased uplink signals in a multipath environment. The two paths are combined inside the DCM maintaining a time delay between both paths. According to measurements signal strength gain is about 3-5 dB for diversity reception. ID No: 161692 PRELIMINARY Page 77 User’s Manual for Node C Network Elements 5.3.2 RF and DC Distribution Unit The RF and DC distribution unit is mounted between the duplexers and DCMs. It is the physical transport layer for communication between the downlink DCM (which has the integrated controller) and other sub-components of the Node C (see also chapter 3.2.5 Connection of Cable Bridge). 13 10 11 12 figure 5-9 RF / DC distribution unit 10 11 12 13 To cable bridge connector from Interface Unit for connection of 12V, GND, 28 V DL-PA connector LEDs for voltage indication (left: 28 V, right: 12V) 28 V to DCM modules Door contact Connector for door contact RS485 connection to extension unit Fan connector (NodeM 43) Memory board connector To cable bridge connector for USB connection from Interface Unit To cable bridge connector from Interface Unit RF cables UL PA connector table 5-1 Connections of RF / DC distribution unit Page 78 M0121A1A_uc.doc 5 Functional Description 5.3.3 Digital Channel Module (DCM) The task of the digital channel module (DCM) is to filter and amplify any signals passing through it. In addition it takes measurements of the input and output signals and decodes the air interface to ensure proper setup and operation. Finally it performs the interference cancellation algorithms, which eliminate the normal problems associated with isolation, and has an integrated controller (in the DL part) for the entire Node C, which maintains a web server for local and remote communication. This process is accomplished by both analogue and digital means. In case the diversity option is equipped, the module receives signals from both the primary duplexer and diversity filter. Both signals are combined digitally and filtered before being amplified in the uplink amplifier. The DCM consists of an UL and DL part. figure 5-10 DCM (UL or DL part) ID No: 161692 PRELIMINARY Page 79 User’s Manual for Node C Network Elements 5.3.4 Uplink Final Amplifier The UL path is amplified by a final amplifier for high output power. figure 5-11 Uplink final amplifier 5.3.5 Downlink Final Amplifier In the DL path, an error-correcting feed-forward amplifier, which has a high output power while maintaining superior intermodulation and linearity performance, is used as final stage. In the Node C x37 a 37 dBm (2 W) average power final amplifier is used. figure 5-12 Node C x37 DL final amplifier Page 80 M0121A1A_uc.doc 5 Functional Description In the Node C x43 a 43 dBm (20 W) average power final amplifier is used. figure 5-13 Node C x43 DL final amplifier, new type figure 5-14 Node C x43 DL final amplifier, former version ID No: 161692 PRELIMINARY Page 81 User’s Manual for Node C Network Elements 5.3.6 Distribution & Alarm Board The distribution & alarm board of the Interface Unit is the main connection point for the user. It has the external alarm clamps, RS232 connectors, for local or modem connection, as well as a summary alarm relays. The following figures show one blank board and an installed one with battery backup. Battery backup connector Internal I2C Vdc for modem * Remote (RS232)* Internal PSTN connector External alarms & PSTN * Door switch Modem cable (RF connection) USB connector for modem* Power supply alarming / I2C Mains surveillance Battery load discharge (resistor) Modem fuses (2.5 A) Local (RS232) * Battery charge module Summary alarm*; see chapter 5.2.7 for pin assignment figure 5-15 Distribution & alarm board Only these connectors are for general customer use. All others are designated above for informative purposes, and required, only, e.g. for an upgrade or replacement of parts. Page 82 M0121A1A_uc.doc 5 Functional Description 5.3.7 Power Supply The power supply, which is mounted in the Interface Unit, transforms AC mains power into a predefined DC voltage. When performing maintenance, ensure that all circuits are voltage-free and that the Node C is disconnected from mains. The Node C may be equipped with a second power supply for redundancy. figure 5-16 Power supply 5.4 OPTIONAL EQUIPMENT The actual configuration can be seen at the configuration list*, which is part of the delivery. To be replaced by an electronic list that will be accessible via software. 5.4.1 Modem with Battery Backup The modem is used to establish a remote connection to the Node C. The connection may be used to change the unit’s parameters, check and clear alarms or collect measurement and quality statistics. Furthermore, the modem is at the Node C’s request to alert the operator when there is an alarm. The modem may be over-the-air (wireless) or PSTN. It is possible to install the wireless modem or the PSTN modem on site. ID No: 161692 PRELIMINARY Page 83 User’s Manual for Node C Network Elements À Check the communication mode between the modem and the terminal. The following parameters should be set for a GSM modem. Bit rate / bit per second: 9600 baud Number of data bit: 8 bit Parity bit: No parity Stop bit: 1 stop bit These settings may only be changed locally. Should a different modem be used, the operator should ensure that the settings are changed prior to leaving the site. 5.4.1.1 Initstrings The initialization string depends on the operator’s network and the modem. It may be necessary to adjust the init string in the field. The following init string is factory set. Modem Network not yet available t.b.d. via Node C Web Interface: t.b.d. Initstring table 5-2 Standard initstring for modem 5.4.1.2 Wireless Modem The wireless modem allows remote control and maintenance of the Node C. Parameters may be changed; alarm and measurement statistics may be acknowledged and collected in the OMC. The modem is installed in the cover of the Interface Unit. The antenna connector for the modem is located at the connector panel of the Interface Unit For technical data of the modem refer to chapter 7.2.3 Specifications for Optional Equipment. Page 84 M0121A1A_uc.doc 5 Functional Description 5.4.1.3 Battery Backup In case power fails, a battery backup system for controller and modem has been implemented. This provides enough power for the controller that is integrated into the downlink DCM and the modem to operate for a limited period of time (see chapter 7.2.3 Specifications for Optional Equipment for battery backup time). Within this time, the Node C will initiate a call to the OMC and alert the operator that power has been lost. All other functions will cease to work in case of power failure. The battery packs are protected from deep discharge by use of a low voltage disconnect unit. When performing preventive maintenance, make sure that all circuits are voltage free by disconnecting the battery cable (C1) from its connector (C2). In case of a power cycle, it is sufficient to press the “Battery disconnect button” to interrupt the voltage supply. After mains is connected again, the battery will be charged and the battery backup function will be activated automatically. LED Battery charge module C2 connector Battery pack C1; to C2 of charge module C3 connector Battery disconnect button figure 5-17 Battery backup module, exemplary The battery charge module is plugged directly onto the distribution & alarm board of the Interface Unit through connector C3. The battery pack should be discharged at regular intervals of about three months to optimize its service life. This service discharge may be activated via software depending on the software version. The time required for the discharge varies depending e.g. on the charge status of the battery pack. A fully charged battery may require up to some hours to be completely discharged. Consider this when activating the discharge and also observe the following note. ) Note: Please be aware that the backup function is not available during discharge. Thus, a primary voltage failure in that time will result in a complete system shut-down. It is recommended to replace the battery pack of the battery backup option after two years of usage as a preventive measure. The nominal lifetime of the battery pack is approx. two years under normal environmental conditions. ID No: 161692 PRELIMINARY Page 85 User’s Manual for Node C Network Elements When the battery is charging, an LED on the module turns on. When the battery is fully charged, the LED will switch off. The location of the battery backup parts are illustrated in figure 6-2 Location of battery backup. For technical data of the battery backup module refer to chapter 7.2.3 Specifications for Optional Equipment. 5.4.2 PSU Redundancy The Node C Interface Unit may be equipped with two power supplies. This guarantees full power redundancy. The PSUs are interconnected by a current control line for current load sharing with a ratio of approx. 50% to each supply. Currently the PSU redundancy option is only available for Node C x37. 5.4.3 High Rejection Filter This software option provides a highly sophisticated filter feature that can be controlled via the “Technician Setup” menu of the web page (see figure 4-7 Technician Setup menu). Page 86 M0121A1A_uc.doc 6 Maintenance 6 MAINTENANCE 6.1 GENERAL Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. ) Note: The Node C does not require any preventative maintenance measures. It is only recommended to replace the battery pack of the battery backup option after two years of usage as a preventive measure. The nominal lifetime of the battery pack is approx. two years under normal environmental conditions. In the event of a malfunction, the user should check the status of the antennas, feeder cables, connectors, and mains power before replacing any components. 6.2 REPLACEMENT OF COMPONENTS Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. Maintenance of the Node C should be performed on a FRU (Field Replaceable Unit) basis only. Do not damage the warranty labels on the components, as this voids the warranty. The spare parts list contains only units that can be replaced without tuning or complex soldering work. Those units are all components of the Interface Unit. Do not replace any components inside the Node C itself. ) Note: Defect parts should only be replaced by original parts from the supplier. All interventions inside the housing are at one’s own risk. ) Note: During maintenance ensure that the unit has been disconnected from mains. To open the cabinet of the Interface Unit, observe the instructions in chapter 4.1 General. ) Note: If the optional battery backup is installed, disconnect the battery cable from the charge module connector as described in chapter 5.4.1.3 Battery Backup, to ensure that all circuits are voltage-free. ) Note: Before disconnecting any cables, label any unlabeled cables to ensure correct reconnection, and check the switch positions of the removed part to set the switches of the new part accordingly. To replace a FRU, use the appropriate tools. The tools are provided along with the equipment. Replacement tools may be ordered from the supplier. All screws have a right-hand thread, turn the tool clockwise for tightening and counter-clockwise for loosening. ID No: 161692 PRELIMINARY Page 87 User’s Manual for Node C Network Elements SMA connectors have a specified torque of 100 Ncm. Use an appropriate tool to fasten and unfasten these. Do no over tighten the connectors or screws. The table below shows various screws with their respective torques. Screw Type Thread size M 2.0 M 2.5 M 3.0 M 4.0 M 5.0 Tallow-drop 40 82 145 330 650 Socket head cap Countersunk head Specified Torque (in Ncm) not in use 40 not in use 82 100 145 330 330 tbd. 650 table 6-1 Specified torques for various screw types ) Note: ) Note: ) Note: Depending on the configuration of the Node C the FRU can be equipped with a 50-Ohm termination resistor. In such a case, use the termination resistor of the old FRU to terminate the respective connector of the replacement part. After the replacement of a component, check whether the system has to be levelled anew. Do not forget to reinstall the front cover after the replacement procedure to ensure safe operation. If any FRU not contained in the following chapter needs to be replaced, contact customer service for additional instructions. 6.2.1 Power Supply • To remove a power supply, first disconnect all cables. • Unscrew the seven M4 socket head cap screws by which each power supply is fastened to the cabinet. • Use these screws to fasten the new power supply and reconnect all cables. figure 6-1 Power supply screws Page 88 M0121A1A_uc.doc 6 Maintenance 6.2.2 Battery Backup Snap connectors Battery pack Battery charge module figure 6-2 Location of battery backup • Before removing the battery charge module and battery, disconnect the battery cable from the battery charge module (see also figure 5-17 Battery backup). • The battery can now be unplugged easily. • Release the charger from the two snap connectors by which it is fastened and disconnect it from its socket on the distribution & alarm board. • To install the new module, proceed in reverse order. 6.2.3 • Fan Unit Unscrew the three M5x6 socket head screws by which the fan unit is screwed to the cabinet. Be careful not to lose the according washers. figure 6-3 Fan unit screws ID No: 161692 PRELIMINARY Page 89 User’s Manual for Node C Network Elements • Take off the fan unit and disconnect the connector cable from the cabinet. Disconnecting the fan connector cable Positioning the fan connector cable figure 6-4 Fan connector cable • 6.2.4 To install the new fan unit, proceed in reverse order. In order not to squeeze the fan connector cable, take care to position it correctly after its reconnection. Modem The optional modem is screwed to a mounting plate which is fastened to the cabinet. In order to separate the modem from the plate, the mounting plate has to be taken off first. • Before starting to remove the mounting plate, disconnect all cables. • Then, unscrew the four tallowdrop screws M3x6 which fasten the mounting plate to the cabinet. • Take off the plate with the modem attached. The modem is fastened from the back to the plate with two countersunk head screws M4x10. • Unscrew these screws and use them to fasten the new modem to the mounting plate. Position of modem • Fasten the mounting plate again with the four tallow-drop screws M3x6 and reconnect all cables. figure 6-5 Mounting plate of modem Page 90 M0121A1A_uc.doc 7 Appendix 7 APPENDIX 7.1 ILLUSTRATIONS 7.1.1 Cabinet Drawings figure 7-1 Cabinet of a Node C ID No: 161692 PRELIMINARY Page 91 User’s Manual for Node C Network Elements figure 7-2 Cabinet of a Node C Interface Unit Page 92 M0121A1A_uc.doc 7 Appendix 7.1.2 Layout figure 7-3 Layout of the Node C 1937, exemplary ID No: 161692 PRELIMINARY Page 93 User’s Manual for Node C Network Elements figure 7-4 Layout of the Node C 1943, exemplary Page 94 M0121A1A_uc.doc 7 Appendix Position for optional modem figure 7-5 Layout of the Interface Unit, exemplary ID No: 161692 PRELIMINARY Page 95 User’s Manual for Node C Network Elements 7.2 SPECIFICATIONS 7.2.1 Electrical Specifications ) Note: For detailed information, refer to the Environmental and Safety Specifications leaflet of the supplier. Type Frequency Option 1: Option 2: 1 CDMA carrier DL output 2 CDMA carriers power * 4 CDMA carriers UL composite output power Output power step size Output power accuracy over all conditions Min. DL input power for full output power Max. input power without damage Min. antenna isolation for max. gain UL noise figure Delay Option 1: Option 2: Maximum gain Gain adjust range Return loss Uplink diversity Spectral emission mask CDMA carriers Out of band gain Option 1: (rejection) Option 2: Modulation accuracy Spurious emissions Far off selectivity (ultimate rejection) Power supply Standard: Optional: Power idle: consumption full output power: RF connectors Input / output impedance Cabinet: Ingress protection Fan: Temperature range Node C 837 Node C 843 Uplink: 824 – 849 MHz Downlink: 869 – 894 MHz 1-11 adjacent (per module) 1.23 MHz carriers 1-3 adjacent (per module) 5 MHz carriers +37.0 dBm +43.0 dBm +34.0 dBm +40.0 dBm +31.0 dBm +37.0 dBm +23 dBm 1 dB ±1.5 dB -56 dBm -60 dBm +10 dBm 73 dB minimum 83 dB minimum 3.5 dB 6.0 µs 8.2 µs 93 dB 103 dB 43 dB to 93 dB 53 dB to 103 dB 15 dB Standard -45 dBc @ 750 kHz -60 dBc @ 1.98 MHz Gain -40 dB in 1.25 MHz Gain -70 dB in 1.25 MHz RHO > 0.96 -13 dBm 70 dB 110 VAC / 40-60 Hz 36-72 VDC 200 W 300 W 250 W 500 W 7/16 DIN female; N female 50 Ohms IP66 IP66 --IP55 -33°C to +50°C * see next page All data is subject to change without notice Page 96 M0121A1A_uc.doc 7 Appendix Type Frequency Option 1: Option 2: 1 CDMA carrier DL output 2 CDMA carriers power * 4 CDMA carriers UL composite output power Output power step size Output power accuracy over all conditions Min. DL input power for full output power Max. input power without damage Min. antenna isolation for max. gain UL noise figure Delay Option 1: Option 2: Maximum gain Gain adjust range Return loss Uplink diversity Spectral emission mask CDMA carriers Out of band gain Option 1: (rejection) Option 2: Modulation accuracy Spurious emissions Far off selectivity (ultimate rejection) Power supply Standard: Optional: Power idle: consumption full output power: RF connectors Input / output impedance Cabinet: Ingress protection Fan: Temperature Range Node C 1937 Node C 1943 Uplink: 1850 – 1910 MHz Downlink: 1930 – 1990 MHz 1-11 adjacent (per module) 1.23 MHz carriers 1-3 adjacent (per module) 5 MHz carriers +37.0 dBm +43.0 dBm +34.0 dBm +40.0 dBm +31.0 dBm +37.0 dBm +23 dBm 1 dB ±1.5 dB -56 dBm -60 dBm +10 dBm 73 dB minimum 83 dB minimum 3.5 dB 6.0 µs 8.2 µs 93 dB 103 dB 43 dB to 93 dB 53 dB to 103 dB 15 dB Standard -45 dBc @ 750 kHz -60 dBc @ 1.98 MHz Gain -40 dB in 1.25 MHz Gain -70 dB in 1.25 MHz RHO > 0.96 -13 dBm 70 dB 110 VAC / 40-60 Hz 36-72 VDC 200 W 300 W 250 W 500 W 7/16 DIN female; N female 50 Ohms IP66 IP66 --IP55 -33°C to +50°C * The manufacturer’s rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. All data is subject to change without notice ID No: 161692 PRELIMINARY Page 97 User’s Manual for Node C Network Elements 7.2.2 Mechanical Specifications Description Node C x37 Height, width, depth Weight * Cooling Node C x43 546 x 320 x 260 mm 22 kg Natural convection in the door and on the back Acoustic noise None Description 25 kg Twin redundant fans in the door Natural convection on the back 45 dBA typ. @ 25°C ambient 58 dBA typ. @ 50°C ambient Interface Unit Height, width, depth Weight * Cooling 546 x 190 x 260 mm 13 kg Natural convection in the door and in the back * in standard configuration All data is subject to change without notice 7.2.3 Specifications for Optional Equipment Modem Service Service connection Physical connection Power consumption Connectors t.b.d. t.b.d. RS232; USB (not yet available) 4W average, 10W peak Data, power, RF Battery backup Battery type Battery capacity Nominal output voltage Backup time Charge time Maintenance discharge time Major features NiCd 1200mAh 8.4 V >15minutes (25W load @ 25°C) 4.5 hours maximum 2 hours Battery charge and discharge control, active HID, battery voltage measurement All data is subject to change without notice Page 98 M0121A1A_uc.doc 7 Appendix 7.3 PARTSLISTS The following lists contain a list of all FRUs that are available for the Node C and Interface Unit. The Node C configuration is available in the configuration list1, which is delivered with the unit. Please observe that in the following lists only the components marked * may be replaced on site. If the replacement of any other component in this list is required, please contact customer service for assistance. To be replaced by an electronic door label that will be accessible via software. 7.3.1 Interface Unit Interface Unit 159557 Battery Backup Kit Cabinet Combining Kit Charge Control Board Connecting- and Sparepart Kit Cover Distribution and Alarm Board Drawer Modem Memory board 1627.2 I2C-ADD 51 Modem Kit USA/BBU L-Cab. NiCd-Akku 8,4V/1200mAh, N-1200SCK,70°C Power Supply In:115Vac±15%, 47-65Hz Power Supply In:230Vac±15%, 47-65Hz Wall Mounting Kit 159548 * 161240 160098 160069 160736 160415 160734 t.b.d. 159809 161489 * 160188 * 159126 * 159514 * 160068 The manufacturer reserves the right to replace the parts listed above by equivalent substitutes! ID No: 161692 PRELIMINARY Page 99 User’s Manual for Node C Network Elements 7.3.2 Node C NodeC Type 837 843 Description Node C 1937 1943 ID No. 160546 160545 160543 160544 Adapter 7/16 male -N female 112425 Cover 160735 Digital Channel BW 15 MHz 869-894MHz Module DL BW 15 MHz 1930-1990MHz 160548 --- --- 160550 Digital Channel BW 15 MHz 824-849MHz Module UL BW 15 MHz 1850-1910MHz 160547 --- --- 160549 Drawer Duplexer DL / LNA:824-849/869-894MHz 160733 161464 --- --- 161462 161463 --- --- 161461 Duplexer DL / LNA:1850-1910/1930-1990MHz Duplexer UL / LNA:824-849/869-894MHz Duplexer UL / LNA:1850-1910/1930-1990MHz Fan Unit 1 --- 159547 Fin.Amp. 26-28V, 47dB, 1930-1990MHz Fin.Amp.4W M,12V,33dB 824-849MHz --- 159547 --- 160254 160417 --- Fin.Amp.4W M,12V,33dB 1850-1910MHz --- 160416 Fin.Amp.30W,26-28V,36dB 1930-1990,Feedf. --- Fin.Amp. 82W, MLPA 28V/46dB/869-894MHz --- Fin.Amp. 82W, MLPA 28V/36dB/869-894MHz 161235 160255 158789 ----- Memory board 1627.2 I2C-ADD 50 159810 Pole mounting 160979 Pole mounting Kit (2 Systems) 161604 Pole mounting Kit Back to Back (1System) 161605 RF/DC Distribution Unit 159539 Wall Mounting Kit 160068 --- The fan unit can only be replaced as a whole. Do not replace an individual fan. The manufacturer reserves the right to replace the parts listed above by equivalent substitutes! Page 100 M0121A1A_uc.doc 8 Index 8 INDEX Abbreviations............................................7 Address of Mikom.....................................9 Alarmforwarding .....................................73 Alarms Fan Unit Replacement............................89 Feed-Forward Amplifier..........................80 Filters External .....................................................74 Management .............................................65 Setting of Severity Level ...........................65 Setting of Threshold ..................................65 High Rejection Option............................... 86 Standard Feature...................................... 72 Final Amplifier.........................................80 Amplifier Feed-Forward............................................80 Final...........................................................80 Grounding...............................................21 Antenna Tuning ......................................62 Health and Safety Warnings.....................8 High Rejection Filter ...............................86 Battery Backup .......................................85 Replacement .............................................89 Block Diagram DC .............................................................69 RF..............................................................70 Cabinet Drawing Interface Unit .............................................92 Node C ......................................................91 Commissioning.......................................25 Communication Mode Parameters.........84 Connections Antenna .....................................................23 Cable Bridge..............................................23 Login Devices............................................26 Login Procedures ......................................26 Optional Equipment...................................24 Power ........................................................22 Installation Direct connection on Win2000 ................. 48 Direct Connection on WinXP.................... 28 Electrical ................................................... 20 Mechanical ............................................... 13 Modem Connection on WinXP ................. 38 USB Driver................................................ 27 International Contact Addresses ............10 Layout Interface Unit ............................................ 95 Node C 1937 ............................................ 93 Node C 1943 ............................................ 94 Total.......................................................... 76 Control Board .........................................82 LNA ........................................................76 Low-Noise Amplifier ...............................76 DCM Module ..........................................79 Design ....................................................70 Digital ICE ..............................................72 Distribution & Alarm Board .....................82 Diversity............................................77, 79 Duplexer .................................................76 External Alarms ......................................74 Menus Alarm Management .................................. 65 Connectivity and Upload........................... 63 Setup Wizard ............................................ 61 Technician Setup...................................... 64 Modem General ..................................................... 83 Initstrings .................................................. 84 Replacement ............................................ 90 Wireless .................................................... 84 Naming ......................................................65 ID No: 161692 PRELIMINARY Page 101 User’s Manual for Node C Network Elements Mounting Brackets ..............................................16, 18 Connection Option ....................................16 General......................................................13 Pole ...........................................................17 Wall ...........................................................14 SMS Alarmforwarding ............................73 Software Setup.................................26, 66 Specifications Electrical (Node C 19xx)........................... 97 Electrical (Node C 8xx)............................. 96 Mechanical ............................................... 98 Optional Equipment .................................. 98 Optional Equipment................................83 Summary Alarm......................................75 Troubleshooting......................................66 Partslist Interface Unit .............................................99 Node C ....................................................100 Power Supply .........................................83 Replacement .............................................88 Preamble ..................................................9 PSU Redundancy...................................86 USB Adapter ..................................................... 26 Driver ........................................................ 27 Remote Control ......................................26 Remote Login .........................................26 Replacement of VSWR.....................................................73 Battery Backup ..........................................89 Fan Unit.....................................................89 Modem ......................................................90 Power Supply ............................................88 Web Page Access ...................................................... 60 Main Menus .............................................. 61 RF Path ..................................................71 RF/DC Distribution Unit ..........................78 RSSI .......................................................73 Page 102 M0121A1A_uc.doc
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Page Count : 102 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:e7814667-d7f0-4a4b-9fe1-199c0a748f5c Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:02:16 16:29:55+01:00 Create Date : 2004:02:16 16:29:55+01:00 Document ID : uuid:a164e5c8-b74f-49da-9455-3e6f807a8d8d Format : application/pdf Title : Microsoft Word - M0121A1A_uc.doc Creator : ursula_neubauer Author : ursula_neubauerEXIF Metadata provided by EXIF.tools