   Optical Remote Unit  ION™-M17P/17P/17P (M-Cabinet)    User's Manual M0143AWA
 User’s Manual for Remote Unit ION™-M17P/17P/17P Page 2  M0143AWA_uc.doc                              © Copyright 2011 CommScope, Inc.  All rights reserved. Andrew Solutions is a trademark of CommScope, Inc.  All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher.  Andrew Wireless Systems GmbH, 04-August-2011
   Page 3 TABLE OF CONTENTS 1. GENERAL 5 1.1. USED ABBREVIATIONS 5 1.2. HEALTH AND SAFETY WARNINGS 6 1.3. ABOUT ANDREW SOLUTIONS 8 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 9 2. INTRODUCTION 12 2.1. PURPOSE 12 2.2. ION-M17P/17P/17P 12 3. FUNCTIONAL DESCRIPTION 14 3.1. GENERAL 14 3.2. COMPONENTS OF THE ION-M17P/17P/17P REMOTE UNIT 15 3.2.1. Components Inside the Unit 15 3.2.2. Fan-Protection Kit 16 3.2.3. Accessories 16 4. COMMISSIONING 18 4.1. MECHANICAL INSTALLATION 18 4.1.1. General 18 4.1.2. Wall-Mounting Procedure 20 4.1.3. Pole-Mounting Procedure 21 4.1.4. Mounting of Fan Protection 23 4.2. ELECTRICAL INSTALLATION 24 4.2.1. General 24 4.2.2. Connections 25 4.2.3. Grounding 26 4.2.4. Connection of the Antenna Cables 27 4.2.5. Power Connection 28 4.3. OPTICAL-FIBRE-CABLE CONNECTION - RULES 29 4.3.1. Protective Plug 30 4.3.2. Protective-Tube Kit 32 4.4. COMMISSIONING 34 5. ALARMS 38 5.1. BITE AND ALARMS 38 5.2. HANDLING OF ALARMS 38 5.3. ALARM STATUS 38 5.4. STATUS LED ALARMS 38 5.5. EXTERNAL ALARM INPUTS AND OUTPUTS 40 5.6. TROUBLESHOOTING 41
 User’s Manual for Remote UnitION™-M9/18P/21P EP Page 4  M0143AWA_uc.doc 6. MAINTENANCE 42 6.1. GENERAL 42 6.2. REPLACING THE FAN UNIT 43 6.3. CLEANING THE HEAT SINK 45 7. APPENDIX 46 7.1. ILLUSTRATIONS 46 7.2. SPECIFICATIONS 47 7.2.1. Electrical Specifications 47 7.2.2. Environmental and Safety Specifications 48 7.2.3. Mechanical Specifications 48 7.3. SPARE PARTS 49 8. INDEX 50    FIGURES AND TABLES  figure 3-1 Configuration of an ION-M17P/17P/17P remote unit................................ 14 figure 3-2 Remote unit, front view, fully RF equipped............................................... 15 figure 3-3 Remote unit, backside, fully RF equipped ................................................ 15 figure 4-1 Wall mounting, (metric dimensions).......................................................... 20 figure 4-2 Pole-mounting kit...................................................................................... 21 figure 4-3 Pole mounting (metric dimensions) .......................................................... 22 figure 4-4 Mounting procedure for fan protection, (metric dimensions)..................... 23 figure 4-5 Connector flange of ION-M17P/17P/17P.................................................. 25 figure 4-6 RS232 connector...................................................................................... 26 figure 4-7 Grounding bolt with loosened hex nut ...................................................... 26 figure 4-8 Grounding bolt, schematic view................................................................ 26 figure 4-9 AC mains plug .......................................................................................... 28 figure 4-10 Protective-plug assembly ....................................................................... 30 figure 4-11 Tube-kit installation................................................................................. 33 figure 5-1 Flange connector, 5 poles ........................................................................ 40 figure 5-2 Flange connector, 7 poles ........................................................................ 40 figure 5-3 Alarm inputs and outputs, standard.......................................................... 41 figure 7-1 Installation drawing................................................................................... 46  table 1-1 List of international contact addresses....................................................... 10 table 4-1 Specified torques....................................................................................... 19 table 4-2 RS232 connector, pin assignment............................................................. 26 table 5-1 Status LED alarms..................................................................................... 39
1 General   Page 5 1. GENERAL 1.1.  USED ABBREVIATIONS 3GPP   3rd Generation Partnership Project AC    Alternating current / Direct Current AIMOS  Andrew Integrated Management and Operating System ALC    Automatic Level Control BITE    Built-In Test Equipment BTS    Base Transceiver Station CE    "Conformité Européenne" ("European Conformity") CD   Compact Disk CPD    Channel Power Detection DL   Downlink DoC   Declaration of Conformity EDGE   Enhanced Data Rates for GSM Evolution EN   European Norm EP   Extension Port ESD   Electrostatic Discharge ETS    European Telecommunication Standard EU   Extension Unit FRU    Field Replaceable Unit GSM    Global System for Mobile Communication GND   Ground GUI    Graphical User Interface ICP3    Intercept Point 3rd order ID No    Identification Number ION    Intelligent Optical Network IP   Ingress Protection ISO    International Organization for Standardization LED    Light Emitting Diode LMT    Local Maintenance Terminal LTE    Long Term Evolution MIMO    Multiple Input Multiple Output MS   Mobile Station MU   Main Unit NF   Noise Figure OTRx    Optical Transceiver = SRMU (Subrack Master Unit) PG   Packing Gland PIM   Passive Intermodulation R&TTE  Radio & Telecommunications Terminal Equipment Rev   Revision RF   Radio Frequency RU   Remote Unit RX   Receiver SNMP   Simple Network Management Protocol TS   Technical Specification TX   Transmitter UL   Uplink UMTS   Universal Mobile Telecommunication System UPS    Uninterruptible Power Supply VSWR   Voltage Standing Wave Ratio W CDMA  Wideband Code Division Multiple Access WDM    Wavelength Division Multiplex
User’s Manual forRemote Unit ION™-M17/17P/17P Page 6  M0143AWA_uc.doc1.2.  HEALTH AND SAFETY WARNINGS  1.  Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2.  Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3.  Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 4.  Keep operating instructions within easy reach and make them available to all users. 5.  It is the responsibility of the network provider to implement prevention measures to avoid health hazards which may be associated to radiation from the antenna(s) connected to the unit. 6.  Note for a Class A digital device or peripheral: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 7.  Make sure, access is restricted to qualified personnel. 8.  Only licence holders for the respective frequency range are allowed to operate this unit. 9.  Corresponding local particularities and regulations must be observed. For national deviations please refer to the respective documents included in the manual CD delivered. 10. Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. 11. Due to power dissipation, the repeater may reach a very high temperature. Do not operate this equipment on or close to flammable materials.
1 General   Page 712. Before opening the unit, disconnect mains. 13. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 14. This unit complies with European standard EN60950. 15. Make sure the repeater settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met. 16. Although the repeater is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the repeater’s antenna connectors for protection against atmospheric discharge. 17. Laser radiation! Do not stare into the beam; do not view it directly or with optical instruments.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 8  M0143AWA_uc.doc 1.3.  ABOUT ANDREW SOLUTIONS  Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage for every application: outdoor use, indoor installations, tunnels, subways and many more.  Andrew Wireless Systems GmbH has unparalleled experience in providing RF coverage and capacity solution for wireless networks in both indoor and outdoor environment and belongs to Andrew Solutions, a CommScope Company.  Andrew Solutions is the foremost supplier of one-stop, end-to-end radio frequency (RF) solutions. Our products are complete solutions for wireless infrastructure from top-of-the-tower base station antennas to cable systems and cabinets, RF site solutions, signal distribution, and network optimization.  Andrew Solutions has global engineering and manufacturing facilities. In addition, it maintains field engineering offices throughout the world.  We operate a quality management system in compliance with the requirements of ISO 9001. All equipment is manufactured using highly reliable material. In order to ensure constant first-rate quality of the products, comprehensive quality monitoring is conducted at all fabrication stages. Finished products leave the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal operation.  ) Note:  Exceptions of and national deviations from this intended use may be possible. To observe corresponding local particularities and regulations, please refer to the respective documents (also in national language) which are included in the manual CD delivered.  To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions.   For technical assistance and support, please also contact the local office or Andrew Solutions directly at one of the addresses listed in the following chapter.
1 General   Page 9 1.4.  INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT  Americas:  Canada United States Andrew Solutions Canada  Andrew Solutions,  Andrew LLC, A CommScope Company Mail  620 North Greenfield Parkway Garner, NC 27529 U.S.A.  Mail  620 North Greenfield Parkway Garner, NC 27529 U.S.A. Phone  +1-905-878-3457 (Office) +1-416-721-5058 (Mobile) Phone +1-888-297-6433 Fax +1-905-878-3297  Fax  +1-919-329-8950 E-mail  Peter.Masih@commscope.com, WIsupport.us@commscope.com  E-mail WIsupport.us@commscope.com   Brazil & South America  Mexico, Central America &  Caribbean region CommScope Cabos do Brasil Ltda.  Andrew Corporation Mexico,  SA DE CV Mail Av. Com. Camilo Julio 1256 Predio B Zonal Industrial CP 597 Sorocaba SP 18086-000 Brazil Mail Av. Insurgentes Sur 688, Piso 6 Col. Del Valle,  Deleg. Benito Juárez – CP: 03100 Mexico, D.F. Mexico Phone  + 55-15-9104-7722 +55-15-2102-4142  Phone  +52-55-1346-1900 (Office) +52-1-55-5419-5260 (Mobile) Fax + 55-15-2102-4001  Fax +52-55-1346-1901 E-mail WIsupport@commscope.com  E-mail WIsupport@commscope.com   APAC Countries:  China, India and Rest of Asia  Australia & New Zealand Andrew International Corporation  Andrew Corporation (Australia) Pty Ltd. Mail Room 915, 9/F  Chevalier Commercial Centre 8 Wang Hoi Rd Kowloon Bay  Hong Kong Mail Unit 1 153 Barry Road Campbellfield  VIC  3061 Australia Phone +852-3106-6100  Phone +613-9300-7969 Fax +852-2751-7800  Fax +613-9357-9110 E-mail WIsupport.China@commscope.com  E-mail WIsupport.Australia@commscope.com
User’s Manual forRemote Unit ION™-M17/17P/17P Page 10  M0143AWA_uc.doc Europe:  United Kingdom  France Andrew Solutions UK Ltd  CommScope France Mail Unit 15, Ilex Building Mulberry Business Park Fishponds Road  Wokingham Berkshire RG41 2GY England Mail Immeuble Le Lavoisier 4, Place des Vosges 92052 Courbevoie France Phone +44-1189-366-792  Phone  +33-1 82 97 04 00 Fax +44-1189-366-773  Fax  +33-1 47 89 45 25 E-mail WIsupport.uk@commscope.com E-mail WIsupport@commscope.com   Germany Czech Republic Andrew Wireless Systems GmbH  Andrew Solutions Czech Republic C-Com, spol. s r.o Mail  Industriering 10 86675 Buchdorf Germany  Mail  U Moruší 888 53006 Pardubice Czech Republic Phone +49-9099-69-0  Phone  +420-464-6280-80 Fax +49-9099-69-930  Fax  +420-464-6280-94 E-mail WIsupport@commscope.com  E-mail WIsupport@commscope.com  Austria Switzerland Andrew Wireless Systems (Austria) GmbH  Andrew Wireless Systems AG Mail  Weglgasse 10 2320 Wien-Schwechat Austria  Mail  Tiergartenweg 1 CH-4710 Balsthal Switzerland Phone +43-1706-39-99-10  Phone  +41-62-386-1260 Fax +43-1706-39-99-9  Fax  +41-62-386-1261 E-mail WIsupport.austria@commscope.com E-mail WIsupport.ch@commscope.com  Italy  Spain and Portugal Commscope Italy S.r.l., Faenza, Italy  Andrew Solutions España S.A. A Commscope Company Mail  Via Mengolina, 20 48018 Faenza (RA) Italy  Mail Avda. de Europa, 4 - 2ª pta. Parque Empresarial La Moraleja 28108 Alcobendas (Madrid) Spain Phone +39-0546-697111  Phone +34-91-745-20 40 Fax +39-0546-682768  Fax +34-91-661-87 02 E-mail WIsupport.italia@commscope.com  E-mail WIsupport.iberia@commscope.com table 1-1 List of international contact addresses
1 General   Page 11 For you notes:
User’s Manual forRemote Unit ION™-M17/17P/17P Page 12  M0143AWA_uc.doc 2. INTRODUCTION 2.1.  PURPOSE Cellular telephone systems transmit signals in two directions between base transceiver station (BTS) and mobile stations (MS) within the signal coverage area.  If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distribution system.  Such a system contains an optical Master Unit and several Remote Units. The number of the Remote Units depends on the hardware and software configuration. The Remote Units are connected to the Master Unit with optical links. The optical loss must be less than 10 dB inclusive optical couplers or splitters.  The Master Unit is the connection to the base transceiver stations. The configuration of a Master Unit depends on the number of the Remote Units and the frequency range.   WDM (Wave Division Multiplex) filters are integrated in the optical modules. For the UL, a wavelength within 1540 nm – 1562 nm is used. For the DL, a wavelength of 1310 ±20 nm is used. The maximum output power for the UL and DL is 5.7 mW.  2.2.  ION-M17P/17P/17P  Andrew Solutions ION-M17P/17P/17P is a 3 sector single-box remote unit. It is used in conjunction with a master unit in the ION optical distribution system. This system transports 3 sectors (3 x 1700/2100 MHz) simultaneously, providing a cost-effective solution for distributing capacity from one or more base stations.  The ION-M17P/17P/17P transports signals on the RF layer in a very inexpensive manner. This means that multiple operators and multiple technologies are moved simultaneously from a cluster of base stations to a remote location over the same fibre.  The ION optical distribution system is a cost-effective coverage solution for dense urban areas, airports, high-rise buildings and other locations where physical structures increase path loss or provide limited space for installation. It has been specifically designed to reduce zoning problems and to provide homogeneous coverage. The compact, mechanical design is specifically architected to mount inside of or on poles and along side structures in such a way that it has a minimal visual impact.  The ION-M platform has been specifically tested and optimized for CDMA2000. Furthermore, it is provisioned for future improvements to the modulation and frequency bands.
2 Introduction   Page 13 The ION is easily set-up and supervised via a graphical user interface (GUI). Remote units can be commissioned through the use of built-in test equipment. An auto-levelling function compensates for the optical link loss making installation easy and quick.  The entire system may be monitored remotely via an Andrew OMC. This is a comprehensive management platform with SNMP protocol and X.733 standard implemented. Should a sophisticated interface not be required, the master unit can be directly connected to the alarm interface of a base station via relay alarming.     3 sector multi-operator support    Reduced visual impact form factor    Efficient, high power amplifier    Single fibre for multiple sectors     Comprehensive operations and management system for configuration and alarming    OMC with SNMP according to X.733 standard    Easy installation and commissioning
User’s Manual forRemote Unit ION™-M17/17P/17P Page 14  M0143AWA_uc.doc3. FUNCTIONAL DESCRIPTION 3.1.  GENERAL  The following figure shows the configuration of an ION-M17P/17P/17P remote unit.  oeoeDLULUL/DLWDM OTRXfrom / to Master UnitOptical Module Control Unit RCM161X113 colors LED4 external alarmsinputs4 external alarmsoutputs+28 VDC outputFinal Amplifier 1 2110 - 2155 MHzSector 1LNADPXDuplexer UnitUL-active 1710-1755 MHz 2110-2155 MHzPower Supply Unit Mains+28 VDCI²C+28 VDCI²CRF + DCAC IN 100-240 VX6FanActive Cooling Kit 4442+28 VDCI²C2110 - 2155 MHz  625 - 755 MHz2300/2385 MHz1710 -1755 MHz  545 - 675 MHz1400/1485 MHz2110 - 2155 MHz1710 - 1755 MHzRS232Final Amplifier 22110 - 2155 MHzI²C +28 VDCFinal Amplifier 32110 - 2155 MHz+28 VDCI²CDPXDPXLNALNARF + DCRF + DCSector 2Sector 3ConverterConverterDPXConverterConverter2385DPX1400 MHz230014001485  625 - 755 MHz  625 - 670 MHz  710-  755 MHz1485 MHz1400 MHz  545 -  675 MHz  545 -  590 MHz  630 - 675 MHz2300 MHz2385 MHz2110 - 2155 MHz1710 - 1755 MHz1710 - 1755 MHz2110 - 2155 MHz2110 - 2155 MHz2110 - 2155 MHz1710 - 1755 MHz1710 - 1755 MHz1485 MHz2300 MHz2385 MHzConversion Module+28 VDCI²CBufferBufferBufferBufferBuffer1485 MHz1400 MHzE1154B0 figure 3-1 Configuration of an ION-M17P/17P/17P remote unit
3 Functional Description   Page 153.2.  COMPONENTS OF THE ION-M17P/17P/17P REMOTE UNIT   The actual configuration of the remote unit can be seen at the configuration list which is part of the delivery.  3.2.1.  Components Inside the Unit  The following figures show exemplary views of a fully equipped ION-M17P/17P/17P remote unit – except for the fan housing without cover – to illustrate the individual components.       Air outletAir inlet PSU Distribution unit Duplexers Optical module Amplifiers Conversion module Control Unit figure 3-2 Remote unit, front view, fully RF equipped    figure 3-3 Remote unit, backside, fully RF equipped
User’s Manual forRemote Unit ION™-M17/17P/17P Page 16  M0143AWA_uc.doc 3.2.2.  Fan-Protection Kit  In order to protect the fan unit (e.g. against rain), a protective cover to be mounted over the air inlet is delivered with the unit. For indoor applications, mounting of the fan-protection kit is not mandatory.  For more details see chapter 4.1.4 Mounting of Fan Protection.  3.2.3.  Accessories  For the accessories available for the remote unit, e.g. overcoat housing, connecting box or iso-trafo kit, a separate manual is available.
3 Functional Description   Page 17 For your notes:
User’s Manual forRemote Unit ION™-M17/17P/17P Page 18  M0143AWA_uc.doc4. COMMISSIONING 4.1.  MECHANICAL INSTALLATION 4.1.1.  General Read the health and safety warnings in chapter 1.2. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met.  2. It is recommended only to use the mounting hardware delivered by the supplier. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded.  ) Note:  Exceeding the specified load limits may cause the loss of warranty!  3.   The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system.  4. Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation as specified in the individual mounting procedures.  5.  When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables.  6. Also observe all additional rules or restrictions regarding mounting that depend on the type of Remote Unit. For details refer to chapter 7.2.2 Mechanical Specification. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be kept, as in the following illustrations:
4 Commissioning   Page 19  7.  A spacing of 40 mm (1.58 inch) around the unit is required.  8.  To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 17 x 17 cm (290 cm2). Make sure, too, there is no thermal short circuit between the air inlet and air outlet.  If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit.  Specified torques have to be observed for certain mounting procedures according to the following table:  Type  Lens head screws  Hex nuts  Spacing bolts  PG (plastic)  PG (aluminium)Thread M 4  M 8  M 4  M 8  PG 13.5  PG 29 Specified torques 3.3 Nm  27 Nm 2.3 Nm  27 Nm 3.75 Nm  10 Nm table 4-1 Specified torques  ) Note:  To avoid damage when mounting the unit, always make sure that the M8 washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the mounting drillings of the unit.  The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 20  M0143AWA_uc.doc4.1.2.  Wall-Mounting Procedure     Check the suitability of the wall-mounting kit and the wall.     Mark the position of the drilling holes (for measurements refer to figure 4-1 Wall mounting). Drill four holes at the marked positions and insert dowels *.     Use a cap nut or lock nut to screw the four dowel screws into the dowels and put the distance tubes over the screws.     Hang the mounting brackets of the Remote Unit into the screws, and fasten them immediately using the washers and nuts.     Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded.   Wall mounting with active cooling kit4.0  0.504Mains supply980 ± 0.50122 ± 0.5018796 ± 1.00G0946Z0 figure 4-1 Wall mounting, (metric dimensions) * The dowels are not part of the delivery since the suitable type depends on the on-site conditions (material of wall). Therefore, use dowels that are appropriate for the mounting surface.
4 Commissioning   Page 214.1.3.  Pole-Mounting Procedure  Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a column or other similar structures. Additional hardware must be used for this type of installation. Such a pole-mounting kit could include two threaded rods M8, two U-beams and mounting material like bolts and nuts.   figure 4-2 Pole-mounting kit     Use the screw bands to fasten the two U-beams to the pole as illustrated in figure 4-3 Pole mounting.  ) Note:  When fastening the U-beams make sure that they are installed congruently and not at an angle to each other. To determine the distance between the beams refer to 4.1.2 Wall-Mounting Procedure for measurements.     Hang the mounting brackets of the Remote Unit into the threaded bolts of the U-beam, and fasten them immediately using the washers and nuts.  Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 22  M0143AWA_uc.doc G0764M6Lock for folding screw band ES 119 TESPA screw band, stainless, 11 mm Optical Remote UnitWasher DIN 125 Form B Ø 8.0Lock washer for M8.0 DIN 127 A2 Form B Hexagon nut  M8 DIN 934PolePolePole-mounting bracketØ140Ø40 figure 4-3 Pole mounting (metric dimensions)
4 Commissioning   Page 234.1.4.  Mounting of Fan Protection  Since the fan protection is required for the outdoor usage of a stand-alone Remote Unit, the mounting of this optional equipment is also described in this manual.     To install the protective cover of the fan protection kit, first unscrew the four screws with the respective lock washers from the cover of the air inlet of the Remote Unit, and instead, screw in the four spacing bolts M4.0x30 with the four lock washers M4.0 DIN125 that are part of the fan protection kit.     Place the protective cover into the right position by fitting its four bore holes over the spacing bolts and fasten it using the original lock washers and screws of the Remote Unit. (These lock washers and screws are also part of the fan protection kit and can be used as spare parts in case of loss.)  2x M4.0x8fillister-head screws2x lock washersremove the screwand the lock washer!2x lock washers2x M4.0x8fillister-head screwsremove the screwand the lock washer!2x M4.0x8fillister-head screws1x rain protective cover2x lock washers2x M4.0x8fillister-head screws2x  M4.0x8 fillister-head screws2x lock washersremove the screwand the lock washer!2x washers2x washers156152 17120AIR STREAM2x M4.0x30spacing boltsG0496MF  figure 4-4 Mounting procedure for fan protection, (metric dimensions)
User’s Manual forRemote Unit ION™-M17/17P/17P Page 24  M0143AWA_uc.doc4.2.  ELECTRICAL INSTALLATION 4.2.1.  General  Read the health and safety warnings in chapter 1.2. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed. 2.  It is compulsory to ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3.  Although the Remote Unit is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is strongly recommended to insert additional lightning protection. 4.  If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains circuit must be provided within easy reach. 5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains supply is disconnected. 6.  Make sure that an appropriate circuit breaker and an overcurrent limiting device are connected between mains and Remote Unit. 7.  A connection of mains supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9.  To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. It is sufficient to tighten the N-antenna connector hand-screwed. Any use of a tool (e.g. pair of pliers) might cause damage to the connector and thus lead to malfunctioning of the Remote Unit. 11. For unstabilized electric networks which frequently generate spikes, it is advised to use a voltage limiting device.  12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection) depending on the individual application in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables.
4 Commissioning   Page 254.2.2.  Connections      figure 4-5 Connector flange of ION-M17P/17P/17P   Alarm output Mains  Status LED  N-connector mobile Sector 3 connector Grounding bolt External alarm input N-connector mobile Sector 2 Control  connector Optical-fibre connector  N-connector mobile Sector 1
User’s Manual forRemote Unit ION™-M17/17P/17P Page 26  M0143AWA_uc.docControl Connector RS232 - Local Interface  This 8-pin male connector (type: Binder Series 712) is primarily to support local control of the remote unit via RS232 ASCII interface.    PIN Assignment 1  Not connected (n.c.) 2 RS232 Rx 3 RS232 Tx 4 n.c. 5 GND* (RS232) 6 n.c. 7 n.c. 8 n.c. figure 4-6 RS232 connector  table 4-2 RS232 connector, pin assignment  *  GND is the abbreviation of Ground  4.2.3.  Grounding  Grounding must be carried out. Connect an earth-bonding cable to the grounding connection provided at the outside of the remote unit (see chapter 4.2.2 Connections). Do not use the grounding connection to connect external devices.   figure 4-7 Grounding bolt with loosened hex nut  figure 4-8 Grounding bolt, schematic view  After loosening the hex nut, connect the earth-bonding cable between the two washers as illustrated in the figures above. Then, fasten all parts again with the hex nut.
4 Commissioning   Page 274.2.4.  Connection of the Antenna Cables  The remote unit has N-type antenna connectors. For its location please refer to chapter 4.2.2 Connections. For mounting the cable connectors, it is recommended to refer to the corresponding documentation of the connector manufacturer. The bending radius of the antenna cables must remain within the given specifications.  For the selection of cable and antenna it should be considered that, on the one hand, a cable with higher loss is less expensive but, on the other hand, it impairs performance.   It is sufficient to tighten the N-type antenna connectors hand-tight. The use of a tool (like pliers) may cause damage to the connector and, therefore, lead to a malfunctioning of the remote unit.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 28  M0143AWA_uc.doc4.2.5.  Power Connection  Before connecting electrical power to the units, the system must be grounded as described in the previous chapter.  Mains power must be connected at the mains connector of the unit (see chapter 4.2.2 Connections).  The power supply plug is part of the delivery. The correct wiring of the power supply plug is as follows:   figure 4-9 AC mains plug    For the AC power supply connection, a minimum cross section of 1.5 mm2 is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit.  ) Note:  Do not connect or disconnect the power cord at the mains connector while power is on. Turn off mains * power before connecting the power cord at the remote unit, then, engage mains again. *   Mains power must be interruptible with an external mains breaker. For the mains breaker, observe the following recommendation:  120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240-Volt service.
4 Commissioning   Page 294.3.  OPTICAL-FIBRE-CABLE CONNECTION - RULES  Optical signals are transmitted by use of optical fibres. When connecting these fibres observe the following instructions.   ) Note:  Care should be taken when connecting and disconnecting fibre-optic cables. Scratches and dust significantly affect system performance and may permanently damage the connector. Always use protective caps on fibre-optic connectors not in use.  In general, optical fibres do not need special protective measures. However, protection against environmental influences e.g. rodents and humidity must be considered.  The optical fibre is a single mode fibre. Type is E9/125 µm with the following minimum requirements:  Attenuation:   <0.36 dB / km @ 1310 nm  /  <0.26 dB / km @ 1550 nm Dispersion:  <3.5 ps / nm km @ 1310 nm  /  <18.0 ps / nm km @ 1550 nm  The specified bending radius of the optical fibres must not be exceeded. The pigtails for the connection between master unit and remote unit must have a sufficient length. A protection for the feeding into units must be given. The system attenuation of the optical fibres, including the connectors, must not exceed 10 dB.  System attenuation and attenuation of optical components must be determined. This can be achieved by measuring attenuation and reflection with an appropriate measuring instrument. For pigtails, a total value of < 0.4 dB (measured to a reference plug) can be assumed due to the dead zone of the reflectometer. These measurements must be made with a sufficient length of optical fibre, at the input and output of the device which has to be measured.  Fibre-cable connectors have to be of the same type (E2000APC8°) as the connectors used for the unit. The fibre-optic cables are connected to the optical transceiver.    Angled connectors are not compatible with straight optical connectors; non-compatibility of connectors will result in permanent damage to both connectors.  Before connecting the fibre cables, follow the procedure below to ensure optimized performance. It is important for these procedures to be carried out with care:
User’s Manual forRemote Unit ION™-M17/17P/17P Page 30  M0143AWA_uc.doc ¾  Remove fibre-optic protective caps.  ¾  Do not bend the fibre-optic cable in a tight radius (< 4 cm) as this may cause cable damage and interrupt transmission.  ¾  Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of the fibre-optic cable that will be inserted in the optical connectors on the donor interface box.  ¾  Blow out the laser receptacle with clean and dry compressed air to remove any particulate matter.  ¾  Connect the fibre-optic cables by inserting the cable end into the laser receptacle and aligning the key (on the cable end) with the keyed slot.  ¾  Do not use any index-matching gels or fluids of any kind in these connectors. Gels are intended for laboratory use and attract dirt in the field.  4.3.1.  Protective Plug  Connection:  A protective plug is provided for the connection of the fibre-optic cables.   figure 4-10 Protective-plug assembly  ) Note:  Only high-quality connectors must be used for this type of plug. Qualified brands are Diamond or Huber & Suhner.
4 Commissioning   Page 31For plug assembly, observe the following instruction:  1.  Pass one or two contacts through the backshell and the clamp ring. 2.  Place the contact(s) on the lower insulation body by pushing the groove of the contact into the cavity. If there is only one contact, cavity A must be used. * 3.  Then, mount the upper insulation body on the lower insulation body. **   4.  Bring the insulator into the plug. The narrow groove of the insulator must be fitted into the stamp of the plug.    *  To release the contact for disassembling, push the inner snap to the side and pull the contact out. **  To release upper and lower insulation bodies for disassembling, use a small screwdriver and carefully open the snap-connections at the left and the right side of the insulator without damaging them.  5.  Fasten the insulator by screwing the backshell tight onto it. Use a spanner with opening 32 to screw the backshell tight (no gap). 6.  Place the appropriate seal parts (with one groove for one contact or two grooves for two contacts) over the cable(s) and push them into the backshell. Seals with one groove No gap Cavity B Upper insulation body Cavity A
User’s Manual forRemote Unit ION™-M17/17P/17P Page 32  M0143AWA_uc.doc 7.  Bring the plastic ring over the cable(s), push it into the backshell and compress the seals and plastic ring by screwing the clamp ring tight (no gap) using a spanner with opening 20. ***    Screw tight until gap is closed 8. Connect the plug to the optical-fibre connector of the remote unit, again by fitting a stamp on the plug into the groove of the connector.  9.  To lock the connector, push the black locking ring forward.****  ***  For disassembling, release the clamping ring and remove the seals and the plastic ring first. ****  Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The locking ring has to be pushed forward to lock the connector and pulled back to free the connection.  4.3.2.  Protective-Tube Kit  As additional protection for the optical fibers, this connector type can be supplemented by a special tube kit. To fasten the tube correctly, first unscrew the clamp ring (if already installed) of the original plug kit.   Then, proceed according to the following instruction:  Groove  Push forward to lock, pull back to free connection
4 Commissioning   Page 33    Screw the reducer to the protective plug backshell without any gap!Place the appropriate seal parts (with) one groove for one contact or two grooves for two contacts) over the cable(s) and push them into the backshell! Protective tubeReducerCouplingProtective plugFiber cableRing 3/4G1055M0   figure 4-11 Tube-kit installation  Push the fiber-optic cable carefully through the tube until it comes out at the other end.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 34  M0143AWA_uc.doc 4.4.  COMMISSIONING  Read the health and safety warnings in chapter 1.2 as well as the description carefully to avoid mistakes and proceed step by step as described!    Do not operate the remote unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load.    Only qualified personnel should carry out the electrical, mechanical, commissioning and maintenance activities that require the unit to be powered on when open.    When opening the remote unit do not damage the warranty labels on the internal devices. The warranty is void if the seals are broken.    Ensure that all connections have been performed according to chapter 4.2.2 Connections.
4 Commissioning   Page 35Commissioning an ION-M Remote UnitStartMechanical installationFasten wall or pole mounting kit to wall or pole.Manual  for Remote UnitElectrical connectionsConnect grounding cable and ground the RU.MainsSwitch mains power on.Philips screwdriverScrew driverSpanner, size 13 mmElectrical connectionsConnect AC (DC) power to the power cable. Ensure there is a circuit breaker between mains and RU.RF connectionConnect antenna cable to antenna port.Optical connectionsMount the optical fibre with E2000 APC8° connector into the connector. Plug the connector into the RU.Mechanical installationMount RU to mounting kit, ensure suffient air flow and avoid thermal short circuits.PreperationUnpack RU, RU accessories and mounting kit.External devicesConnect external devices to the external in or alarm out connectors, or to the connecting board inside the RU.G1055Z0G1055Z0Mounting kitSpanner, size 13 mmDrilling machineDowelsScrew driverGrounding cableSpanner 13 mmMains cableConnecting kitAlarm kit (M-cabinet)E2000 APC8° connectorSpanner with opening 32
User’s Manual forRemote Unit ION™-M17/17P/17P Page 36  M0143AWA_uc.doc Output:All RUs okay.Go to MUExternal errorClose the door (RUs with a door).  Check externally connected devices.Check fibre loss of optical link.Check optical connectors.Clean optical connectors.Check optical output power of corresponding OTRx at master unit.ALC alarm: Decrease DL input power of affected band.VSWR alarm: Check antenna and cable.LED statusProceed to MU to set up the SWOrangeYesInternal ErrorChange power supply (RUs with a door).Reduce environmental temperature. Eliminate thermal short circuit.Disconnect and connect mains. Fans should run. If not, replace the fans at RU. MU: Change amplifier setting at MU controllerRedLED statusYellowGreenRedFinished setting up all RUs?GreenSpare RU available?YesContact customer serviceNoYesLED on?Check power switch inside RU (RUs with door).Check mains cabling.Check mains power.NoNo
4 Commissioning   Page 37 For your notes:
User’s Manual forRemote Unit ION™-M17/17P/17P Page 38  M0143AWA_uc.doc 5. ALARMS 5.1.  BITE AND ALARMS  The Built-In Test concept comprises the monitoring of the power supplies, the power amplifiers and the optical interface.  All occurring alarms can be checked via software at the master unit.  5.2.  HANDLING OF ALARMS  As soon as the software acknowledges a valid alarm, a message is transmitted to the master unit.  If the reason for the alarm has been cleared or if the alarm should continue, a new alarm message will not be repeated. If there was an interruption of at least five seconds after acknowledgement, a new alarm message will be generated.  5.3.  ALARM STATUS  For details refer to the corresponding software documentation of the master unit. 5.4.  STATUS LED ALARMS  For local supervision, a status LED on the connector flange of the remote unit gives an indication of possible reasons for alarms. This table shows possible on-site measures that could be checked before referring to the master unit alarm list.  Status LED Indication  Alarms  Possible on-site measures Green  No alarm Æ Status ok   Door alarm  Close the door (RUs with door). Alarms not directly related to RU:  External alarms  Check externally connected devices. Optical alarm Rx Check fibre loss of optical link. Check optical connectors. Clean optical connectors. (MU: Check optical output power of corresponding OTRx at master unit). Orange ALC alarm  (MU: Decrease DL input power of affected band). Alarms directly related to RU: Red Power 28 V  Change power supply (RUs with door). Replace the affected remote unit.
5 Alarms   Page 39 Temperature  Reduce environmental temperature.  Eliminate thermal short circuit. Fan  Disconnect and connect mains. Fans should run. If not, replace the fans at RU. I²C  Disconnect and connect mains. Optical alarm Tx  - Amplifier “Power Down”  (MU: Change amplifier setting at MU controller). Status LED off  Mains Check power switch inside of RU (RUs with door). Check mains cabling. Check mains power. table 5-1 Status LED alarms  For the position of the status LED see chapter 4.2.2 Connections.  Explicit troubleshooting is available in the MU software (software manual or WEB Interface).
User’s Manual forRemote Unit ION™-M17/17P/17P Page 40  M0143AWA_uc.doc5.5.  EXTERNAL ALARM INPUTS AND OUTPUTS  G1038Z0  G1038Z0  figure 5-1 Flange connector, 5 poles  figure 5-2 Flange connector, 7 poles   The alarm outputs (open collector output 5 V / 1 mA) are normally low. In case of an alarm they are high active (5 V). They can be used to monitor alarms with an external alarm indicator.  The +28 V pin (for its location see figure 5-2 Flange connector, 7 poles) is protected by a 500 mA thermoswitch. In case of exceeding this current between pin 7 and GND and/or in case of a failure of the VSWR module, the thermoswitch turns into a high-resistive status. In this case no fuse needs to be replaced. Just wait a few minutes until the thermoswitch reaches the normal operating temperature again.  ) Note:  The manufacturer / supplier of this system accepts no liability for damage caused by equipment connected to external outputs or by effects from such equipment.  As accessory equipment the alarm kit (see chapter 7.3 Spare Parts) is available to connect external devices to the external alarm inputs and outputs..
5 Alarms   Page 41With the external alarm inputs it is possible to monitor the status of connected devices, e.g. a UPS, via software. All alarm inputs are normally high (5 V) without connection. The polarity (high/ low) can be set via the software at the Master Unit (for details please see according software manual).  The device to be monitored must be connected so that the alarm contacts will be closed in case of an alarm (I max = 8 mA). The alarm inputs are potential-free with common ground.  Subminiature circular connectors series 712 with five and seven contacts, which are contained in the alarm kit, can be ordered directly from the Binder Connector Group, the manufacturer, or indirectly from Andrew Solutions (see chapter 7.3 Spare Parts).  V1651A1Alarm outputAlarm GNDAlarm GNDAlarm GNDAlarm GNDAlarm inputION-M alarm outputs4700R+5 VION-M alarm inputs+5 V560R figure 5-3 Alarm inputs and outputs, standard   5.6.  TROUBLESHOOTING  The status of the remote unit can be checked via the master unit (for details please refer to the software manual of the Master Controller). Locally, the status can be checked at the LED, see chapter 5.4 Status LED Alarms.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 42  M0143AWA_uc.doc 6. MAINTENANCE 6.1.  GENERAL  Read the health and safety warnings in chapter 1.2. ) Note:  The remote unit does not require preventative maintenance measures. ) Note:  To prevent malfunctions of the cooling system due to dirt or pollution, it is recommended to clean the heat sink at regular intervals. These cleaning intervals depend mainly on the location of the remote unit and the corresponding degree of pollution.  Maintenance of the ION-M17P/17P/17P should be performed by replacing only components that are contained in this chapter. In order to maintain warranty, take care not to damage unintentionally the seals on the modules.  The spare parts list, consequently, contains only units which can be replaced without tuning or soldering work.  ) Note:  When sending back the unit, use an appropriate packaging, see chapter  7.2.2 Environmental and Safety Specifications. We strongly recommend using the original packaging! ) Note:  Defect parts should only be replaced by original parts from the supplier. All interventions inside the housing are at one’s own risk. ) Note:  During maintenance ensure the remote unit has been disconnected from mains. ) Note:  Before disconnecting any cables, label any unlabelled cables to ensure correct connection.  For most maintenance procedures appropriate tools are required to ensure correct handling. All these tools can be ordered from the supplier. For screwing procedures observe that all our screws have a right-hand thread, i.e. for fastening the screws turn the tool clockwise and for unscrewing them turn it counter-clockwise.  Due to the design of the remote unit the only component recommended to be replaced is the fan unit. For replacing any other component, please contact the supplier.
6 Maintenance   Page 436.2.  REPLACING THE FAN UNIT  Replacement of the fan unit is not required as a preventative measure. Only when an alarm indicates a malfunctioning of a fan, must the unit be exchanged. ) Note:  Please observe that the fan unit can only be replaced as a whole. Do not remove the fans separately. Read the health and safety warnings in chapter 1.2 as well as the instructions in chapter 6.1 General before starting with the replacement.   1.  Switch off the remote unit. Make sure mains is disconnected for the following replacement procedure. Then, proceed as follows:  2. Loosen the four tallow-drop screws M4x8 by which the fan plate is screwed to the cabinet. Remove the four screws and the corresponding washers.    3.  Remove the fan unit – by putting slight pressure on the fan plate cover – to a position that allows access to the fan connector and the earth-bonding cable.   4.  Unscrew the fan connector and then disconnect the earth-bonding cable.  Fan-unit connector    Earth-bonding cable ) Note:  To observe the specified torque of 650 Ncm for an M5 thread, use an appropriate tool for the following screwing procedures.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 44  M0143AWA_uc.doc5. To mount the new fan unit, re-connect the earth-bonding cable and the fan connector (see step 4). Then, place the fan unit back into its original position and fix it tight as shown below:     6.  Screw the whole fan unit to the cabinet with the four tallow-drop screws M4x8 (see  step  2). In order not to exceed the specified torque of 330 Ncm, use an appropriate tool.
6 Maintenance   Page 456.3.  CLEANING THE HEAT SINK  ) Note:  Read the health and safety warnings in chapter 1.2  as well as the instructions in chapter 6.1 General before starting with the replacement procedure. Then, proceed as follows: 1.  Switch off the remote unit. Make sure that mains is disconnected for the following procedure.  3. Use compressed air (max. 5 bar) to blow out the heat sink from back to front: 2.  Remove the fan plate with the fan unit from the remote unit as described in chapter  6.2 Replacing the Fan Unit, steps 1 and 2:  4.  In case the dirt cannot be blown out completely and parts of it stick to the ribs of the heat sink, clean the parts concerned carefully from the front using e.g. a brush. Take care that the material is not scratched or damaged.   5.  After cleaning the heat sink, mount the fan unit again according to chapter 6.2 Replacing the Fan Unit, step 6. Then, switch the remote unit back on. Compressed air (5 bar max.)Brush (not metallic)
User’s Manual forRemote Unit ION™-M17/17P/17P Page 46  M0143AWA_uc.doc7. APPENDIX 7.1.  ILLUSTRATIONS   figure 7-1 Installation drawing
7 Appendix   Page 47 7.2.  SPECIFICATIONS 7.2.1.  Electrical Specifications  ION-M17P/17P/17P Electrical Mains power  85 to 264 Vac Power supply  Power consumption  770 watts Optical Connectors  E2000/APC 8°  Optical return loss  45 dB minimum Fiber type  Single mode E9/125 µm Optical link budget  0 to 10 dB +3 dBm nominal Composite input power 2100 MHz @ Conversion module master side  +10 dBm max 1)  -19 dBm min 2) Interface BTS side  1700/2100 MHz  4 connectors System optimized for BTS power  33 dBm 43 dBm 0 dBm Connector  3 x N Female Antenna port  Output power See band specification  Return loss  15 dB 1700/ 2100 MHz (AWS) Uplink  1710 to 1755 MHz Frequency range  Downlink  2110 to 2155 MHz 1 carrier  +43 dBm 2 carriers  +40 dBm 4 carriers  +37 dBm Output power per carrier 3)  CDMA2000  8 carriers  +34 dBm Spurious emission   <-13 dBm / 1 MHz DL output tolerance over frequency  ±1.5 dB DL output tolerance over temperature  ±0.5 dB  ICP3 optimized  NF optimized UL Input ICP3  -15 dBm  -18 dBm UL noise figure 4)  7.5 dB  5.0 dB       Nominal gain  Additional gain Additional Attenuation ICP3 optimized 40 dB  0 - 22 dB  0 - 7 dB Gain DL  NF optimized 40 dB  0 - 22 dB  0 - 7 dB ICP3 optimized 40 dB  ---  0 - 30 dB Gain UL  NF optimized 44 dB  ---  0 - 30 dB 1)  can be compensated by additional attenuation (0 - 7 dB) 2)  can be compensated by additional gain (0 - 22 dB) 3)  PAR 7.5 dB @ 0.1% 4) Note:   The noise figure (NF) stated above refers to one Remote Unit (RU) per sector. The NF system increases with the number of the RUs per sector. It is recommended not to operate above four RUs per sector. With four RUs per sector, the system NF will be increased by 6 dB. All figures are typical values unless otherwise stated.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 48  M0143AWA_uc.doc  System Supervision and Control Commands  RF on/off External control ports Alarms  Summary, Power supply, Optical UL and DL failure, Temperature Supervision  Composite output power All data is subject to change without notice.  7.2.2.  Environmental and Safety Specifications   ) Note:  For detailed information, please refer to the Environmental and Safety Specifications leaflet of the supplier, related to ETS 300 019 (European Telecommunication Standard). Operating temperature range  -33° C to +50° C RF part  IP67 Ingress protection  Fan part  IP55 All figures are typical values unless otherwise stated. All data is subject to change without notice.  7.2.3.  Mechanical Specifications  Height, width, depth **  831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in) Weight  18 kg (39.7 Ib) **   Spacing required 40 mm (1.58 in) around unit All data is subject to change without notice.
7 Appendix   Page 49 7.3.  SPARE PARTS  The following list contains all parts available for the Remote Unit. The configuration of the delivered unit meets the requirements of the customer and can differ depending on the state of the delivery.  Maintenance of the ION-M17P/17P/17P should be performed on an FRU (Field Replaceable Unit) basis only. Do not damage the warranty labels on the components, as this voids the warranty.   If any FRU not contained in the following list needs to be replaced, please contact customer service for additional instructions.  Spare Parts List of the Remote Unit ION-M17P/17P/17P  Designation: ID No: ION-M17P/17P/17P  7634986 Protective Plug E 2000  7160013 Protective Cap E 2000  7158914 Fan Protection Kit  7159097 Fan Unit  7158254 Protective Tube Kit  7162182 Manuals for Optical Remote Unit ION-M17P/17P/17P  7619958-00  Accessories Alarm Kit  7157396 Wall Mounting Wall-Mounting Kit  7158078 ISO Trafo Kit 115 V Wall Mounting  7159340 ISO Trafo Kit 230 V Wall Mounting  7158322 Connecting Box Kit Wall Mounting  7159613 Overcoat Housing Kit Wall Mounting  7159625 Pole Mounting  Pole-Mounting Kit  7157782 ISO Trafo Kit 115 V Pole Mounting  7159623 ISO Trafo Kit 230 V Pole Mounting  7159621 Connecting Box Kit Pole Mounting  7159612 Overcoat Housing Kit Pole Mounting  7159624 The manufacturer reserves the right to replace the spare parts listed above by equivalent substitutes. ) Note:  Only the spare parts listed above are FRUs (= Field Replaceable Units) and can be replaced by the user. For replacement of any other parts, please send the entire Remote Unit back to the manufacturer.
User’s Manual forRemote Unit ION™-M17/17P/17P Page 50  M0143AWA_uc.doc 8. INDEX A Address of Andrew Wireless Systems GmbH....... 10 Alarms Alarm Status .................................................... 38 Bite and Alarms ............................................... 38 External Inputs........................................... 40, 41 Handling of Alarms .......................................... 38 List ................................................................... 41 Outputs ...................................................... 40, 41 RU ................................................................... 41 Status LED....................................................... 38 Andrew Solutions.................................................... 8 B Block Diagram ION-M17P/17P/17P ......................................... 14 C Cleaning the Heat Sink......................................... 45 Commissioning General............................................................ 34 Components Accessories ..................................................... 16 Fan-Protection Kit............................................ 16 Interior ............................................................. 15 Connection Rules Optical-Fibre Cables ........................................ 29 Connections Antenna ........................................................... 27 Connector Flange ............................................ 25 Optical-Fibre Cable.......................................... 29 Power .............................................................. 28 Contact Addresses ................................................. 9 Customer Support Addresses................................. 9 E External Inputs Location ........................................................... 25 F Flange Connector 5 poles ............................................................. 40 7 poles ............................................................. 40 G Grounding............................................................. 26 H Health and Safety Warnings................................... 6 I Illustrations ........................................................... 46 Installation Electrical.......................................................... 24 Mechanical ...................................................... 18 M Maintenance......................................................... 42 Mounting Fan Protection ................................................. 23 Pole (Outside).................................................. 21 Wall.................................................................. 20 O Optical-Fibre Connection Protective Plug ................................................ 30 Protective-Tube Kit .......................................... 32 Outputs Location........................................................... 25 P Pin Assignment External Alarms ............................................... 40 R Replacement of Fan Unit...................................... 43 S Spare Parts .......................................................... 49 Specifications Electrical.......................................................... 47 Environmental and Safety................................ 48 Mechanical ...................................................... 48 T Troubleshooting.................................................... 41