Andrew Wireless System IONM17HP19P ION M Remote Unit for cellular networks User Manual Additional information on SM2009
Andrew Wireless System ION M Remote Unit for cellular networks Additional information on SM2009
User Manual
Optical Remote Unit ION™-M17HP/19P (M-cabinet) User's Manual M0145A0A User’s Manual for ION™-M17HP/19P (M-cab) © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 05-September-2011 Page 2 M0145A0A.doc TABLE OF CONTENTS 1. GENERAL 1.1. USED ABBREVIATIONS 1.2. HEALTH AND SAFETY WARNINGS 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. INTRODUCTION 13 2.1. PURPOSE 13 2.2. THE ION-M17HP/19P (INTELLIGENT OPTICAL NETWORK; MMR) 13 3. FUNCTIONAL DESCRIPTION 15 3.1. GENERAL 15 3.2. 3.2.1. 3.2.2. 3.2.3. COMPONENTS OF THE ION-M17HP/19P REMOTE UNIT Components Inside the Unit Fan-Protection Kit Accessories 16 16 17 17 4. COMMISSIONING 19 4.1. 4.1.1. 4.1.2. 4.1.3. 4.1.4. MECHANICAL INSTALLATION General Wall-Mounting Procedure Pole-Mounting Procedure Mounting of Fan Protection 19 19 21 22 24 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. ELECTRICAL INSTALLATION General Connections Grounding Power Connection 25 25 26 27 27 4.3. CONNECTION OF THE ANTENNA CABLES 28 4.4. 4.4.1. 4.4.2. OPTICAL FIBER CABLE CONNECTION RULES Protective Plug Protective-Tube Kit 29 30 32 4.5. COMMISSIONING 34 Page 3 User’s Manual for ION™-M17HP/19P (M-cab) 5. ALARMS 37 5.1. BITE AND ALARMS 37 5.2. HANDLING OF ALARMS 37 5.3. ALARM STATUS 37 5.4. STATUS LED ALARMS 37 5.5. EXTERNAL ALARM INPUTS AND OUTPUTS 38 5.6. TROUBLESHOOTING 40 6. MAINTENANCE 41 6.1. GENERAL 41 6.2. REPLACING THE FAN UNIT 42 6.3. CLEANING THE HEAT SINK 44 7. APPENDIX 45 7.1. ILLUSTRATIONS 45 7.2. 7.2.1. 7.2.2. 7.2.3. SPECIFICATIONS Electrical Specifications Mechanical Specifications Environmental and Safety Specifications 46 46 47 48 7.3. SPARE PARTS 49 8. INDEX Page 4 51 M0145A0A.doc FIGURES AND TABLES figure 3-1 Configuration of an ION-M17HP/19P Remote Unit................................... 15 figure 3-2 Remote Unit, front side, fully RF equipped ............................................... 16 figure 3-3 Remote Unit, rear side, fully RF equipped................................................ 16 figure 4-1 Wall mounting, (metric dimensions).......................................................... 21 figure 4-2 Pole-mounting kit...................................................................................... 22 figure 4-3 Pole mounting (metric dimensions) .......................................................... 23 figure 4-4 Mounting procedure for fan protection, (metric dimensions)..................... 24 figure 4-5 Connector flange of ION-M17HP/19P ...................................................... 26 figure 4-6 Grounding bolt with loosened hex nut ...................................................... 27 figure 4-7 Grounding bolt, schematic view................................................................ 27 figure 4-8 AC mains plug .......................................................................................... 28 figure 4-9 Protective-plug assembly ......................................................................... 30 figure 4-10 Tube-kit installation................................................................................. 33 figure 5-1 Flange connector, 5 poles ........................................................................ 38 figure 5-2 Flange connector, 7 poles ........................................................................ 38 figure 5-3 Alarm inputs and outputs, standard .......................................................... 39 figure 7-1 Installation drawing................................................................................... 45 table 1-1 List of international contact addresses....................................................... 12 table 4-1 Specified torques ....................................................................................... 20 table 5-1 Status LED alarms..................................................................................... 38 Page 5 User’s Manual for ION™-M17HP/19P (M-cab) For your notes: Page 6 M0145A0A.doc 1 General 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP AC/DC AIMOS ALC BITE BTS CE CD CPD DL DoC EDGE EN EP ESD ETS EU GSM GND GUI ICP3 ID No ION IP ISO LED LMT LTE MIMO MS MU NF OTRx PG PIM R&TTE Rev RF RU RX SNMP TS TX UL UMTS UPS VSWR WCDMA WDM 3rd Generation Partnership Project Alternating current / Direct Current Andrew Integrated Management and Operating System Automatic Level Control Built-In Test Equipment Base Transceiver Station "Conformité Européenne" ("European Conformity") Compact Disk Channel Power Detection Downlink Declaration of Conformity Enhanced Data Rates for GSM Evolution European Norm Extension Port Electrostatic Discharge European Telecommunication Standard Extension Unit Global System for Mobile Communication Ground Graphical User Interface rd Intercept Point 3 order Identification Number Intelligent Optical Network Ingress Protection International Organization for Standardization Light Emitting Diode Local Maintenance Terminal Long Term Evolution Multiple Input Multiple Output Mobile Station Main Unit Noise Figure Optical Transceiver = SRMU (Subrack Master Unit) Packing Gland Passive Intermodulation Radio & Telecommunications Terminal Equipment Revision Radio Frequency Remote Unit Receiver Simple Network Management Protocol Technical Specification Transmitter Uplink Universal Mobile Telecommunication System Uninterruptible Power Supply Voltage Standing Wave Ratio Wideband Code Division Multiple Access Wavelength Division Multiplex Page 7 User’s Manual for ION™-M17HP/19P (M-cab) 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 4. Keep operating instructions within easy reach and make them available to all users. 5. It is the responsibility of the network provider to implement prevention measures to avoid health hazards which may be associated to radiation from the antenna(s) connected to the unit. 6. Note for a Class A digital device or peripheral: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 7. Make sure, access is restricted to qualified personnel. 8. Only licence holders for the respective frequency range are allowed to operate this unit. 9. Corresponding local particularities and regulations must be observed. For national deviations please refer to the respective documents included in the manual CD delivered. 10. Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. 11. Due to power dissipation, the repeater may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Page 8 M0145A0A.doc 1 General 12. Before opening the unit, disconnect mains. 13. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 14. This unit complies with European standard EN60950. 15. Make sure the repeater settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met. 16. Although the repeater is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the repeater’s antenna connectors for protection against atmospheric discharge. 17. Laser radiation! Do not stare into the beam; do not view it directly or with optical instruments. Page 9 User’s Manual for ION™-M17HP/19P (M-cab) 1.3. ABOUT ANDREW SOLUTIONS Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage for every application: outdoor use, indoor installations, tunnels, subways and many more. Andrew Wireless Systems GmbH has unparalleled experience in providing RF coverage and capacity solution for wireless networks in both indoor and outdoor environment and belongs to Andrew Solutions, a CommScope Company. Andrew Solutions is the foremost supplier of one-stop, end-to-end radio frequency (RF) solutions. Our products are complete solutions for wireless infrastructure from top-of-the-tower base station antennas to cable systems and cabinets, RF site solutions, signal distribution, and network optimization. Andrew Solutions has global engineering and manufacturing facilities. In addition, it maintains field engineering offices throughout the world. We operate a quality management system in compliance with the requirements of ISO 9001. All equipment is manufactured using highly reliable material. In order to ensure constant first-rate quality of the products, comprehensive quality monitoring is conducted at all fabrication stages. Finished products leave the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal operation. ) Note: Exceptions of and national deviations from this intended use may be possible. To observe corresponding local particularities and regulations, please refer to the respective documents (also in national language) which are included in the manual CD delivered. To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions. For technical assistance and support, please also contact the local office or Andrew Solutions directly at one of the addresses listed in the following section. Page 10 M0145A0A.doc 1 General 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT Americas: Canada United States Andrew Solutions Canada Andrew Solutions, Andrew LLC, A CommScope Company Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Phone +1-905-878-3457 (Office) +1-416-721-5058 (Mobile) Phone +1-888-297-6433 Fax +1-905-878-3297 Fax +1-919-329-8950 E-mail Peter.Masih@commscope.com, WIsupport.us@commscope.com E-mail WIsupport.us@commscope.com Brazil & South America Mexico, Central America & Caribbean region CommScope Cabos do Brasil Ltda. Andrew Corporation Mexico, SA DE CV Mail Av. Com. Camilo Julio 1256 Zonal Industrial CP 597 Sorocaba SP 18086-000 Brazil Mail Av. Insurgentes Sur 688, Piso 6 Col. Del Valle, CP: 03100 Mexico City Mexico Phone + 55-15-9104-7722 Phone +52-55-1346-1900 (Office) +52-1-55-5419-5260 (Mobile) Fax + 55-15-2102-4001 Fax +52-55-1346-1901 E-mail WIsupport@commscope.com E-mail WIsupport@commscope.com APAC Countries: China, India and Rest of Asia Andrew International Corporation Australia & New Zealand Andrew Corporation (Australia) Pty Ltd. Mail Room 915, 9/F Chevalier Commercial Centre 8 Wang Hoi Rd Kowloon Bay Hong Kong Mail Unit 1 153 Barry Road Campbellfield VIC 3061 Australia Phone +852-3106-6100 Phone +613-9300-7969 Fax +852-2751-7800 Fax +613-9357-9110 E-mail WIsupport.China@commscope.com E-mail WIsupport.Australia@commscope.com Page 11 User’s Manual for ION™-M17HP/19P (M-cab) Europe: United Kingdom France Andrew Solutions UK Ltd CommScope France Mail Unit 15, Ilex Building Mulberry Business Park Fishponds Road Wokingham Berkshire RG41 2GY England Mail Immeuble Le Lavoisier 4, Place des Vosges 92052 Courbevoie France Phone +44-1189-366-792 Phone +33-1 82 97 04 00 Fax +44-1189-366-773 Fax +33-1 47 89 45 25 E-mail WIsupport.uk@commscope.com E-mail WIsupport@commscope.com Germany Czech Republic Andrew Wireless Systems GmbH Andrew Solutions Czech Republic C-Com, spol. s r.o Mail Industriering 10 86675 Buchdorf Germany Mail U Moruší 888 53006 Pardubice Czech Republic Phone +49-9099-69-0 Phone +420-464-6280-80 Fax +49-9099-69-930 Fax +420-464-6280-94 E-mail WIsupport@commscope.com E-mail WIsupport@commscope.com Austria Switzerland Andrew Wireless Systems (Austria) GmbH Andrew Wireless Systems AG Mail Weglgasse 10 2320 Wien-Schwechat Austria Mail Tiergartenweg 1 CH-4710 Balsthal Switzerland Phone +43-1706-39-99-10 Phone +41-62-386-1260 Fax +43-1706-39-99-9 Fax +41-62-386-1261 E-mail WIsupport.austria@commscope.com E-mail WIsupport.ch@commscope.com Italy Spain and Portugal Commscope Italy S.r.l., Faenza, Italy Andrew Solutions España S.A. A Commscope Company Mail Via Mengolina, 20 48018 Faenza (RA) Italy Mail Avda. de Europa, 4 - 2ª pta. Parque Empresarial La Moraleja 28108 Alcobendas (Madrid) Spain Phone +39-0546-697111 Phone +34-91-745-20 40 Fax +39-0546-682768 Fax +34-91-661-87 02 E-mail WIsupport.italia@commscope.com E-mail WIsupport.iberia@commscope.com table 1-1 List of international contact addresses Page 12 M0145A0A.doc 2 Introduction 2. INTRODUCTION 2.1. PURPOSE Cellular telephone systems transmit signals in two directions between base transceiver station (BTS) and mobile stations (MS) within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distribution system. Such a system contains an optical Master Unit and several Remote Units. The number of the Remote Units depends on the hardware and software configuration. The Remote Units are connected to the Master Unit with optical links. The optical loss must be less than 10 dB inclusive optical couplers or splitters. The Master Unit is the connection to the base transceiver stations. The configuration of a Master Unit depends on the number of the Remote Units and the frequency range. WDM (Wave Division Multiplex) filters are integrated in the optical modules. For the UL, a wavelength within 1540 nm – 1562 nm is used. For the DL, a wavelength of 1310 ±20 nm is used. The maximum output power for the UL and DL is 5.7 mW. 2.2. THE ION-M17HP/19P (INTELLIGENT OPTICAL NETWORK; MMR) The ION-M17HP/19P is a multi-band multi-operator Remote Unit with various Extension Units (EUs). It is used in conjunction with a Master Unit (MU) in the ION optical distribution system. This system transports multiple frequency bands simultaneously (PCS 1900 MHz, AWS 1700/2100 MHz and 700 MHz EU), providing a cost-effective solution for distributing capacity from one or more base stations. The ION-M17HP/19P transports signals on the RF layer in a very inexpensive manner. This means that multiple operators and multiple technologies are moved simultaneously from a cluster of base stations to a remote location over the same fiber. The ION optical distribution system is a cost-effective coverage solution for dense urban areas, tunnels, subway, airports, convention centers, high-rise buildings and other locations where physical structures increase path loss. It has been specifically designed to reduce zoning problems and to provide homogeneous coverage. The compact, mechanical design is specifically architected to mount inside of poles or along side structures in such a way that it has a minimal visual impact. Page 13 User’s Manual for ION™-M17HP/19P (M-cab) The ION-M17HP/19P is available in a multi-band configuration supporting 1900 MHz and 1700/2100 MHz in parallel and with extension option 700 MHz additionally. It has been specifically tested and optimized for GSM, EDGE, CDMA2000, EV-DO, WCDMA, HSPA+ and OFDM. Furthermore it is provisioned for future improvements to the modulation and frequency bands. The ION is easily set-up and supervised via a graphical user interface (GUI). Remote Units can be commissioned through the use of built-in test equipment. An autolevelling function compensates for the optical link loss making installation easy and quick. The entire system may be monitored remotely via an Andrew OMC. This is a comprehensive management platform with SNMP protocol and X.733 standard implemented. Should a sophisticated interface not be required, the Master Unit can be directly connected to the alarm interface of a base station via relay alarming. Features at a glance • Multi-band, multi-operator support • Reduced visual impact form factor • Efficient, high power amplifier • Single fiber for multiple bands and multiple remotes • Comprehensive operations and management system for configuration and alarming • OMC with SNMP according to X.733 standard • 3GPP TS25.143/TS25.106/ TS36.143/TS36.106 and 3GPP2C.S0051-0 compliant • Easy installation and commissioning Page 14 M0145A0A.doc 3 Functional Description 3. FUNCTIONAL DESCRIPTION 3.1. GENERAL The following figure shows the configuration of an ION-M17HP/19P Remote Unit. Optical Module WDM UL/DL OTRX DL UL 728-894MHz 935-941MHz 1805-2170MHz 698-849MHz 896-902MHz 1710-2130MHz from / to Master Unit 1900 MHz Power Amplifier 1930 - 1995 MHz +28 VDC I²C Buffer Crossband coupler (part of duplexer unit) 26 I²C +28 VDC Duplexer unit With distribution unit DC X11 X6 3 colors LED Fan X3 2100 MHz 4 external alarms inputs 4 external alarms outputs +28 VDC output Probe (nd) X12 Power Amplifier X12 Control Unit RCM161 Antenna port X12 Buffer RS232 X12 I²C Ext. Board Splitter (part of duplexer unit) +28 VDC 2100 MHz Combiner (part of duplexer unit) 2110 – 2155 MHz Power Amplifier Buffer I²C 100..240VAC I²C +28 VDC Buffer Power Supply Unit AC (100 - 240 VAC) 1710 – 1755 MHz 1850 – 1910 MHz +28 VDC RS485 Ext.- Connector Pin 1: 700MHz DL Pin 2: 700MHz UL Pin 3: n.c. Pin 4: n.c. Pin 5: n.c. Pin 6: RS485 + Pin 7: RS485 - E1187B000 figure 3-1 Configuration of an ION-M17HP/19P Remote Unit Page 15 User’s Manual for ION™-M17HP/19P (M-cab) 3.2. COMPONENTS OF THE ION-M17HP/19P REMOTE UNIT The actual configuration of the Remote Unit can be seen at the configuration list which is part of the delivery. 3.2.1. Components Inside the Unit The following figures show exemplary views of a fully equipped ION-M17HP/19P Remote Unit – except for the fan housing without cover – to illustrate the individual components. Air inlet Air outlet Amplifier AWS 1 Amplifier AWS 2 Amplifier PCS Optical module PSU Distribution unit Duplexer PCS 1900 / AWS 1700/2100 figure 3-2 Remote Unit, front side, fully RF equipped Page 16 figure 3-3 Remote Unit, rear side, fully RF equipped M0145A0A.doc 3 Functional Description 3.2.2. Fan-Protection Kit In order to protect the fan unit (e.g. against rain), a protective cover to be mounted over the air inlet is delivered with the unit. For more details see section 4.1.4 Mounting of Fan Protection. Mounting of the fan-protection kit is only mandatory for outdoor applications, however, not mandatory for indoor applications. 3.2.3. Accessories For the accessories available for the Remote Unit, e.g. overcoat housing, connecting box or iso-trafo kit, a separate manual is available. Page 17 User’s Manual for ION™-M17HP/19P (M-cab) For your notes: Page 18 M0145A0A.doc 4 Commissioning 4. COMMISSIONING 4.1. MECHANICAL INSTALLATION 4.1.1. General Read the health and safety warnings in section 1.2 Health and Safety Warnings. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. It is recommended only to use the mounting hardware delivered by the supplier. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded. ) Note: Exceeding the specified load limits may cause the loss of warranty! 3. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation as specified in the individual mounting procedures. 5. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables. 6. Also observe all additional rules or restrictions regarding mounting that depend on the type of Remote Unit. For details refer to section 7.2.2 Mechanical Specification. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be kept, as in the following illustrations: Page 19 User’s Manual for ION™-M17HP/19P (M-cab) 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 12 x 12 cm (144 cm2). Make sure, too, there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques have to be observed for certain mounting procedures according to the following table: Type Thread Specified torques Tallow-drop Hex Spacing PG PG screws nuts bolts (plastic) (aluminium) M4 M8 M4 M8 PG 13.5 PG 29 3.3 Nm 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm table 4-1 Specified torques ) Note: To avoid damage when mounting the unit, always make sure that the M8 washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the mounting drillings of the unit. The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual. Page 20 M0145A0A.doc 4 Commissioning 4.1.2. Wall-Mounting Procedure Check the suitability of the wall-mounting kit and the wall. Mark the position of the drilling holes (for measurements refer to figure 4-1 Wall mounting). Drill four holes at the marked positions and insert dowels *. Wall mounting with active cooling kit 4.0 0.50 122 ± 0.50 80 ± 0.50 18 Use a cap nut or lock nut to screw the four dowel screws into the dowels and put the distance tubes over the screws. 796 ± 1.00 Hang the mounting brackets of the Remote Unit into the screws, and fasten them immediately using the washers and nuts. Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded. Mains supply G0946Z0 figure 4-1 Wall mounting, (metric dimensions) * The dowels are not part of the delivery since the suitable type depends on the on-site conditions (material of wall). Therefore, use dowels that are appropriate for the mounting surface. Page 21 User’s Manual for ION™-M17HP/19P (M-cab) 4.1.3. Pole-Mounting Procedure Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a column or other similar structures. Additional hardware must be used for this type of installation. Such a pole-mounting kit could include two threaded rods M8, two U-beams and mounting material like bolts and nuts. figure 4-2 Pole-mounting kit Use the screw bands to fasten the two U-beams to the pole as illustrated in figure 4-3 Pole mounting. ) Note: When fastening the U-beams make sure that they are installed congruently and not at an angle to each other. To determine the distance between the beams refer to 4.1.2 Wall-Mounting Procedure for measurements. Hang the mounting brackets of the Remote Unit into the threaded bolts of the U-beam, and fasten them immediately using the washers and nuts. Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded. Page 22 M0145A0A.doc 4 Commissioning TESPA screw band, stainless, 11 mm Optical Remote Unit Washer DIN 125 Form B Ø 8.0 Lock washer for M8.0 DIN 127 A2 Form B Hexagon nut M8 DIN 934 Ø140 Ø40 Lock for folding screw band ES 119 Pole Pole Pole-mounting bracket G0764M6 figure 4-3 Pole mounting (metric dimensions) Page 23 User’s Manual for ION™-M17HP/19P (M-cab) 4.1.4. Mounting of Fan Protection Since the fan protection is required for the outdoor usage of a stand-alone Remote Unit, the mounting of this optional equipment is also described in this manual. To install the protective cover of the fan protection kit, first unscrew the four screws with the respective lock washers from the cover of the air inlet of the Remote Unit, and instead, screw in the four spacing bolts M4.0x30 with the four lock washers M4.0 DIN125 that are part of the fan protection kit. Place the protective cover into the right position by fitting its four bore holes over the spacing bolts and fasten it using the original lock washers and screws of the Remote Unit. (These lock washers and screws are also part of the fan protection kit and can be used as spare parts in case of loss.) remove the screw and the lock washer! 2x M4.0x8 fillister-head screws remove the screw and the lock washer! 2x M4.0x8 fillister-head screws 2x lock washers 2x lock washers 2x washers 2x M4.0x8 fillister-head screws AIR STREAM 2x M4.0x30 spacing bolts 1x rain protective cover 2x lock washers 2x washers 2x M4.0x8 fillister-head screws 2x M4.0x8 fillister-head screws 156 152 171 2x lock washers 20 remove the screw and the lock washer! G0496MF figure 4-4 Mounting procedure for fan protection, (metric dimensions) Page 24 M0145A0A.doc 4 Commissioning 4.2. ELECTRICAL INSTALLATION 4.2.1. General Read the health and safety warnings in section 1.2 Health and Safety Warnings. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed. 2. Ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Although the Remote Unit is internally protected against over-voltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is highly recommended to insert additional lightning protection. 4. If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains circuit must be provided within easy reach. 5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains supply is disconnected. 6. Make sure that an appropriate circuit breaker and an over-current limiting device are connected between mains and Remote Unit. 7. A connection of mains supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew ecatalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. 11. Use a voltage limiting device for unstabilized electric networks that frequently generate spikes. Page 25 User’s Manual for ION™-M17HP/19P (M-cab) 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection), depending on the individual application, in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. 4.2.2. Connections Mains connector RS485 connector Extension Unit connector External alarm input Alarm output Status LED Optical-fibre connector N-antenna connector Mobile Grounding bolt figure 4-5 Connector flange of ION-M17HP/19P Page 26 M0145A0A.doc 4 Commissioning 4.2.3. Grounding Grounding must be carried out. Connect an earth-bonding cable to the grounding connection provided at the outside of the Remote Unit (see section 4.2.2 Connections). Do not use the grounding connection to connect external devices. figure 4-6 Grounding bolt with loosened hex nut figure 4-7 Grounding bolt, schematic view After loosening the hex nut, connect the earth-bonding cable between the two washers as illustrated in the figures above. Then, fasten all parts again with the hex nut. 4.2.4. Power Connection Before connecting electrical power to the RU, the system must be grounded as described in the previous section. Mains power must be connected at the mains connector of the unit (see section 4.2.2 Connections). The power supply plug is part of the delivery. The correct wiring of the power supply plug is as follows: Page 27 User’s Manual for ION™-M17HP/19P (M-cab) figure 4-8 AC mains plug For the AC power supply connection, a minimum cross section of 1.5 mm2 is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. ) Note: Do not connect or disconnect the power cord at the mains connector while power is on. Turn off mains power * before connecting the power cord at the Remote Unit, then, engage mains again. Mains power must be interruptible with an external mains breaker. For the mains breaker, observe the following recommendation: 120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240Volt service. 4.3. CONNECTION OF THE ANTENNA CABLES The Remote Unit has N-type antenna connectors. Please refer to section 4.2.2 Connections for its location. Refer to the corresponding documentation of the connector manufacturer for mounting the cable connectors. The bending radius of the antenna cables must remain within the given specifications. Consider the type of cable best suited for the antenna. Remember that a cable with higher loss is less expensive but impairs performance. Page 28 M0145A0A.doc 4 Commissioning Do not use a tool (e.g. pair of pliers) to tighten the N-type antenna connectors as it might cause damage to the connector and lead to a malfunction of the Remote Unit. It is sufficient to tighten the N-type antenna connectors by hand. ) Note: Directly connect the base station signal to the Master Unit using a coaxial cable to avoid coupling another signal into the system in the DL direction than the single wanted signal transmitted by the base station. 4.4. OPTICAL FIBER CABLE CONNECTION RULES Optical signals are transmitted by use of optical fibers. The optical fiber is a singlemode fiber. Type is E9/125 µm with the following minimum requirements. Attenuation: <0.36 dB / km @ 1310 nm Dispersion: <3.5 ps / nm km @ 1310 nm <0.26 dB / km @ 1550 nm <18.0 ps / nm km @ 1550 nm Follow the procedure below before connecting the fiber cables to ensure optimized performance. These procedures must be carried out carefully: 1. Remove fiber-optic protective caps. 2. Clean the end of the fiber-optic cable that will be inserted in the optical connectors on the donor interface box with high-grade alcohol and lint-free cotton cleaning swabs. 3. Blow out the laser receptacle with clean and dry compressed air to remove any particulate matter. 4. Connect the fiber-optic cables by inserting the cable end into the laser receptacle and aligning the key (on the cable end) with the keyed slot. 5. Measure attenuation and reflection with an appropriate measuring instrument. For pigtails, a total value of < 0.4 dB (measured to a reference plug) can be assumed due to the dead zone of the reflectometer. These measurements must be made with a sufficient length of optical fiber, at the input and output of the device which has to be measured. 6. Do not use any index matching gels or fluids of any kind in these connectors. Gels are intended for laboratory use and attract dirt in the field. Observe the following guidelines when connecting the optical fibers: Do not bend the fiber-optic cable in a tight radius (< 4 cm) as this may cause cable damage and interrupt transmission. The specified bending radius of the optical fibers must not be exceeded. The pigtails for the connection between Master and Remote Unit must have a sufficient length. A protection for the feeding into units must be given. Page 29 User’s Manual for ION™-M17HP/19P (M-cab) System attenuation and attenuation of optical components must be determined. Fiber-cable connectors have to be of the same type (E2000APC) as the connectors used for the unit. The fiber-optic cables are connected to the optical transceiver. Angled connectors are not compatible with straight optical connectors; non-compatibility of connectors will result in permanent damage to both connectors. ) Note: Care should be taken when connecting and disconnecting fiber-optic cables. Scratches and dust significantly affect system performance and may permanently damage the connector. Always use protective caps on fiber-optic connectors not in use. ) Note: In general, optical fibers do not need special protective measures. However, protection against environmental influences e.g. rodents and humidity must be considered. 4.4.1. Protective Plug Connection: A protective plug is provided for the connection of the fibre-optic cables. figure 4-9 Protective-plug assembly ) Note: Page 30 Only high-quality connectors must be used for this type of plug. Qualified brands are Diamond or Huber & Suhner. M0145A0A.doc 4 Commissioning For plug assembly, observe the following instruction: 1. Pass one or two contacts through the backshell and the clamp ring. 2. Place the contact(s) on the lower insulation body by pushing the groove of the contact into the cavity. If there is only one contact, cavity A must be used. * 3. Then, mount the upper insulation body on the lower insulation body. ** Upper insulation body Cavity B Cavity A 4. Bring the insulator into the plug. The narrow groove of the insulator must be fitted into the stamp of the plug. ** To release the contact for disassembling, push the inner snap to the side and pull the contact out. To release upper and lower insulation bodies for disassembling, use a small screwdriver and carefully open the snap-connections at the left and the right side of the insulator without damaging them. 5. Fasten the insulator by screwing the 6. Place the appropriate seal parts (with backshell tight onto it. Use a spanner one groove for one contact or two with opening 32 to screw the grooves for two contacts) over the backshell tight (no gap). cable(s) and push them into the backshell. No gap Seals with one groove Page 31 User’s Manual for ION™-M17HP/19P (M-cab) 7. Bring the plastic ring over the cable(s), push it into the backshell and compress the seals and plastic ring by screwing the clamp ring tight (no gap) using a spanner with opening 20. *** Screw tight until gap is closed 8. Connect the plug to the optical-fibre 9. To lock the connector, push the black connector of the Remote Unit, again locking ring forward.**** by fitting a stamp on the plug into the groove of the connector. Groove Push forward to lock, pull back to free connection *** For disassembling, release the clamping ring and remove the seals and the plastic ring first. **** Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The locking ring has to be pushed forward to lock the connector and pulled back to free the connection. 4.4.2. Protective-Tube Kit As additional protection for the optical fibres, this connector type can be supplemented by a special tube kit. To fasten the tube correctly, first unscrew the clamp ring (if already installed) of the original plug kit. Then, proceed according to the following instruction: Page 32 M0145A0A.doc 4 Commissioning Protective plug Fiber cable Ring 3/4 Reducer Screw the reducer to the protective plug backshell without any gap! Coupling Place the appropriate seal parts (with) one groove for one contact or two grooves for two contacts) over the cable(s) and push them into the backshell! Protective tube Push the fiber-optic cable carefully through the tube until it comes out at the other end. G1055M0 figure 4-10 Tube-kit installation Page 33 User’s Manual for ION™-M17HP/19P (M-cab) 4.5. COMMISSIONING Read the health and safety warnings in section 1.2 Health and Safety Warnings. Keep these guidelines in mind before continuing to the instructions for commissioning: Do not operate the Remote Unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load. Only qualified personnel should carry out the electrical, mechanical, commissioning, and maintenance activities that require the unit to be powered on when open. Do not damage the warranty labels on the devices. The warranty is void if the seals are broken. Ensure that all connections have been performed according to section 4.2.2 Connections. Page 34 M0145A0A.doc 4 Commissioning Commissioning an ION-M Remote Unit Manual for Remote Unit Philips screwdriver Mounting kit Spanner, size 13 mm Drilling machine Dowels Screw driver Screw driver Spanner, size 13 mm Start Preperation Unpack RU, RU accessories and mounting kit. Mechanical installation Fasten wall or pole mounting kit to wall or pole. Mechanical installation Mount RU to mounting kit, ensure suffient air flow and avoid thermal short circuits. Grounding cable Spanner 13 mm Electrical connections Connect grounding cable and ground the RU. Alarm kit (M-cabinet) External devices Connect external devices to the external in or alarm out connectors, or to the connecting board inside the RU. RF connection Connect antenna cable to antenna port. Optical connections Mount the optical fibre with E2000 APC8° connector into the connector. Plug the connector into the RU. E2000 APC8° connector Spanner with opening 32 Mains cable Connecting kit Electrical connections Connect AC power to the power cable. Ensure there is a circuit breaker between mains and RU. G1055Z0 Mains Switch mains power on. Page 35 User’s Manual for ION™-M17HP/19P (M-cab) LED on? No Check power switch inside RU (RUs with door). Check mains cabling. Check mains power. Yes LED status Red Internal Error Change power supply (RUs with a door). Reduce environmental temperature. Eliminate thermal short circuit. Disconnect and connect mains. Fans should run. If not, replace the fans at RU. MU: Change amplifier setting at MU controller Orange Yellow Yes LED status Red Green Spare RU available? External error Close the door (RUs with a door). Check externally connected devices. Check fibre loss of optical link. Check optical connectors. Clean optical connectors. Check optical output power of corresponding OTRx at master unit. ALC alarm: Decrease DL input power of affected band. VSWR alarm: Check antenna and cable. Green No Contact customer service Finished setting up all RUs? No Yes Proceed to MU to set up the SW Go to MU Page 36 Output: All RUs okay. M0145A0A.doc 5 Alarms 5. ALARMS 5.1. BITe AND ALARMS The Built-In Test (BITe) concept comprises the monitoring of the power supplies, the power amplifiers and the optical interface. All alarms occurring can be checked via software at the Master Unit. 5.2. HANDLING OF ALARMS A message is transmitted to the Master Unit when the software acknowledges a valid alarm. A new alarm message will not be repeated if the reason for the alarm is cleared or if the alarm continues. A new alarm message will be generated if the alarm is interrupted for at least five seconds after acknowledgement. 5.3. ALARM STATUS Refer to the corresponding software documentation of the Master Unit for details. 5.4. STATUS LED ALARMS For local supervision, a status LED on the connector flange of the Remote Unit gives an indication of possible reasons for alarms. This table shows possible on-site measures that could be checked before referring to the Master Unit alarm list. Status LED Indication Green Orange Alarms Possible on-site measures No alarm Æ Status ok Door alarm Close the door (RUs with door). Alarms not directly related to RU: External alarms Check externally connected devices. Check fibre loss of optical link. Check optical connectors. Optical alarm Rx Clean optical connectors. (MU: Check optical output power of corresponding OTRx at Master Unit). (MU: Decrease DL input power of ALC alarm affected band). Page 37 User’s Manual for ION™-M17HP/19P (M-cab) Red Status LED off Alarms directly related to RU: Change power supply (RUs with door). Power 28 V Replace the affected Remote Unit. Reduce environmental temperature. Temperature Eliminate thermal short circuit. Disconnect and connect mains. Fans Fan should run. If not, replace the fans at RU. I²C Disconnect and connect mains. Optical alarm Tx Exchange RU. Amplifier “Power (MU: Change amplifier setting at MU Down” controller). Check power switch inside of RU (RUs with door). Mains Check mains cabling. Check mains power. table 5-1 Status LED alarms For the position of the status LED see section 4.2.2 Connections. Explicit troubleshooting is available in the MU software (software manual or WEB Interface). 5.5. EXTERNAL ALARM INPUTS AND OUTPUTS G1038Z0 figure 5-1 Flange connector, 5 poles Page 38 G1038Z0 figure 5-2 Flange connector, 7 poles M0145A0A.doc 5 Alarms The alarm outputs (open collector output 5 V / 1 mA) are normally low. In case of an alarm they are high active (5 V). They can be used to monitor alarms with an external alarm indicator. The +28 V pin (for its location see figure 5-2 Flange connector, 7 poles) is protected by a 500 mA thermoswitch. In case of exceeding this current between pin 7 and GND and/or in case of a failure of the VSWR module, the thermoswitch turns into a highresistive status. In this case no fuse needs to be replaced. Just wait a few minutes until the thermoswitch reaches the normal operating temperature again. ) Note: The manufacturer / supplier of this system accepts no liability for damage caused by equipment connected to external outputs or by effects from such equipment. As accessory equipment the alarm kit is available to connect external devices to the external alarm inputs and outputs. For the exact ID No., please refer to section 7.3 Spare Parts. With the external alarm inputs it is possible to monitor the status of connected devices, e.g. a UPS, via software. All alarm inputs are normally high (5 V) without connection. The polarity (high/ low) can be set via the software at the Master Unit (for details please see according software manual). The device to be monitored must be connected so that the alarm contacts will be closed in case of an alarm (I max = 8 mA). The alarm inputs are potential-free with common ground. Subminiature circular connectors series 712 with five and seven contacts, which are contained in the alarm kit, can be ordered directly from the Binder Connector Group, the manufacturer, or indirectly from Andrew Solutions. For the ID No. of the alarm kit see section 7.3 Spare Parts. ION-M alarm outputs ION-M alarm inputs +5 V +5 V 560R 4700R Alarm output Alarm input Alarm GND Alarm GND Alarm GND Alarm GND V1651A1 figure 5-3 Alarm inputs and outputs, standard Page 39 User’s Manual for ION™-M17HP/19P (M-cab) 5.6. TROUBLESHOOTING The status of the Remote Unit can be checked via the Master Unit (for details please refer to the software manual of the Master Controller). Locally, the status can be checked at the LED, see section 5.4 Status LED Alarms. Page 40 M0145A0A.doc 6 Maintenance 6. MAINTENANCE 6.1. GENERAL Read the health and safety warnings in section 1.2. ) Note: The Remote Unit does not require preventative maintenance measures. ) Note: To prevent malfunctions of the cooling system due to dirt or pollution, it is recommended to clean the heat sink at regular intervals. These cleaning intervals depend mainly on the location of the Remote Unit and the corresponding degree of pollution. Maintenance of the ION-M17HP/19P should be performed by replacing only components that are contained in this section. Take care not to unintentionally damage the seals on the modules to maintain warranty. Please keep these guidelines in mind during maintenance: The spare parts list, consequently, contains only units which can be replaced without tuning or soldering work. ) Note: Use an appropriate packaging when sending back the unit (see section 7.2.2 Mechanical Specifications for details). We strongly recommend using the original packaging. ) Note: Defective parts should only be replaced by original parts from the supplier. All interventions inside the housing are at one’s own risk. ) Note: Ensure the Remote Unit has been disconnected from mains during maintenance. ) Note: Label any unlabelled cables before disconnecting them to ensure correct re-connection. Maintenance procedures require appropriate tools to ensure correct handling. All these tools can be ordered from the supplier. ) Note: All our screws have a right-hand thread and are fastened by turning the tool clockwise and are unscrewed by turning the tool counter-clockwise. Due to the design of the Remote Unit the only component recommended to be replaced is the fan unit. For replacing any other component, please contact the supplier. Page 41 User’s Manual for ION™-M17HP/19P (M-cab) 6.2. REPLACING THE FAN UNIT Replacement of the fan unit is not required as a preventative measure. Only if an alarm indicates a malfunctioning of a fan must the unit be exchanged. ) Note: Please observe that the fan unit can only be replaced as a whole. Do not remove the fans separately. Read the health and safety warnings in section 1.2 as well as the instructions in section 6.1 General before starting with the replacement. 1. Switch off the Remote Unit. Make sure mains is disconnected for the following replacement procedure. Then, proceed as follows: 2. Loosen the four tallow-drop screws M4x8 by which the fan plate is screwed to the cabinet. Remove the four screws and the corresponding washers. 3. Remove the fan unit – by putting slight pressure on the fan plate cover – to a position that allows access to the fan connector and the earth-bonding cable. 4. Unscrew the fan connector and then disconnect the earth-bonding cable. Fan-unit connector Earth-bonding cable ) Note: Page 42 To observe the specified torque of 650 Ncm for an M5 thread, use an appropriate tool for the following screwing procedures. M0145A0A.doc 6 Maintenance 5. To mount the new fan unit, re-connect the earth-bonding cable and the fan connector (see step 4). Then, place the fan unit back into its original position and fasten it tight as shown below: 6. Screw the whole fan unit to the cabinet with the four tallow-drop screws M4x8 (see step 2). In order not to exceed the specified torque of 330 Ncm, use an appropriate tool. Page 43 User’s Manual for ION™-M17HP/19P (M-cab) 6.3. CLEANING THE HEAT SINK ) Note: Read the health and safety warnings in section 1.2 Health and Safety Warnings as well as the instructions in section 6.1 General before starting with the replacement procedure. Then, proceed as follows: 1. Switch off the Remote Unit. For the following procedure ensure that mains has been disconnected before! 2. Remove the fan plate with the fan unit 3. Use compressed air (max. 5 bar) to from the Remote Unit as described in blow out the heat sink from back to section 6.2 Replacing the Fan Unit, front: steps 1 and 2: Compressed air (5 bar max.) Brush (not metallic) 4. In case the dirt cannot be blown out completely and parts of it stick to the ribs of the heat sink, clean the parts concerned carefully from the front using e.g. a brush. Take care that the material is not scratched or damaged. 5. After cleaning the heat sink, mount the fan unit again according to section 6.2 Replacing the Fan Unit, step 6. Then, switch the Remote Unit back on. Page 44 M0145A0A.doc 7 Appendix 7. APPENDIX 7.1. ILLUSTRATIONS figure 7-1 Installation drawing Page 45 User’s Manual for ION™-M17HP/19P (M-cab) 7.2. SPECIFICATIONS 7.2.1. Electrical Specifications Electrical Mains power 100 Vac to 240 Vac Power supply max. temp., fully loaded 900 watts Power consumption room temp. idle 550 watts Optical Link Connectors E2000/APC 8° Optical return loss 45 dB minimum Fiber type Single mode E9/125 µm Optical link budget 0 dB to 10 dB 1900 MHz 1700/ 2100 MHz 700 MHz +3 dBm +6 dBm +3 dBm Input power @ OTRx master side composite composite composite Minimum BTS input power 1) -19 dBm -16 dBm -19 dBm RF Interface 1900 MHz 1700/ 2100 MHz 700 MHz Number of connectors Master Unit System optimized for 33 dBm BTS power 43 dBm Connector N female Antenna Port Output power See band specification of RU Return loss 15 dB typical 1700/ 2100 MHZ (AWS) UL 1710 MHz to 1755 MHz Frequency range DL 2110 MHz to 2155 MHz Number of carriers RF output power CDMA 46 dBm 43 dBm 40 dBm 37 dBm per carrier 2) 46 dBm 43 dBm 40 dBm 37 dBm UMTS 4) 46 dBm 43 dBm 40 dBm 37 dBm LTE Spurious emission <-13 dBm / 1 MHz Adjacent channel power -48 dBc DL output tolerance over frequency ±1.0 dB DL output tolerance over temperature ±0.5 dB 3) ICP3 optimized NF optimized UL Input ICP3 -12 dBm -18 dBm 7 dB 4.5 dB UL Noise figure (NF) 5) 11 dB max. 6 dB max. DL 40 dB 40 dB Gain UL 40 dB 47 dB 1) 2) Additional DL gain (22 dB) available in case of low power BTS Applicable to single modulation mode only. Page 46 M0145A0A.doc 7 Appendix 1900 MHz UL 1850 to 1915 MHz Frequency range DL 1930 to 1995 MHz Number of carriers GSM 43 dBm 40 dBm 37 dBm 34 dBm RF output power per CDMA 43 dBm 40 dBm 37 dBm 34 dBm carrier 2) UMTS 43 dBm 40 dBm 37 dBm 34 dBm 4) LTE 43 dBm 40 dBm 37 dBm 34 dBm Spurious emission <-13 dBm / 1 MHz DL output tolerance over frequency ±1 dB DL output tolerance over temperature ±0.5 dB 3) ICP3 optimized NF optimized UL Input ICP3 -12 dBm -18 dBm dB 4.5 dB UL Noise figure (NF) 5) 11 dB max. 6 dB max. DL 40 dB 40 dB Gain UL 40 dB 47 dB All figures are typical values unless otherwise stated. 3) 4) 5) With active cooling For carrier bandwidth <5 MHz output power shall be decreased by 3 dB Note: The noise figure (NF) stated above refers to one Remote Unit (RU) per sector. The NF-system increases with the number of the RUs per sector. It is recommended not to operate above four RUs per sector. With four RUs per sector, the system NF will be increased by 6 dB. Commands Alarms Supervision System Supervision and Control RF on/off External control ports Summary; Power supply; Optical UL and DL failure; Temperature Output power on a per-channel and per-band basis (optional) All data is subject to change without notice. 7.2.2. Mechanical Specifications Height, width, depth * Weight 831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in) 20 kg (44 Ib) * Spacing required 40 mm (1.58 in) around unit All data is subject to change without notice. Page 47 User’s Manual for ION™-M17HP/19P (M-cab) 7.2.3. Environmental and Safety Specifications ) Note: For detailed information, please refer to the Environmental and Safety Specifications leaflet of the supplier, related to ETS 300 019 (European Telecommunication Standard). Operating temperature range RF part Ingress protection Fan part -33° C to +50° C IP67 IP55 All data is subject to change without notice. Page 48 M0145A0A.doc 7 Appendix 7.3. SPARE PARTS The following lists contain all parts available for the Remote Unit. The configuration of the delivered unit meets the requirements of the customer and can differ depending on the state of the delivery. Maintenance of the ION-M17HP/19P should be performed on an FRU (Field Replaceable Unit) basis only. Do not damage the warranty labels on the components, as this voids the warranty. The following spare parts lists only contain units that can be replaced without tuning or soldering work. To replace an FRU, use the appropriate tools. Replacement tools may be ordered from the supplier. If any FRU not contained in the following list needs to be replaced, please contact customer service for additional instructions. Spare Parts List of the Remote Unit ION-M17HP/19P Designation: ID No: FRU 7634985 ION-M17HP/19P Protective Plug E2000 Protective Cap E 2000 Fan Protection Kit Fan Unit Protective Tube Kit Manuals for ION-M17HP/19P 7160013 7158914 7159097 7158254 7162182 7638872-00 Accessories Wall Mounting Wall-Mounting Kit ISO Trafo Kit 115 V Wall Mounting ISO Trafo Kit 230 V Wall Mounting Connecting Box Kit Wall Mounting Overcoat Housing Kit Wall Mounting Pole Mounting Pole-Mounting Kit ISO Trafo Kit 115 V Pole Mounting ISO Trafo Kit 230 V Pole Mounting Connecting Box Kit Pole Mounting Overcoat Housing Kit Pole Mounting Alarm Kit 7158078 7159340 7158322 7159613 7159625 7157782 7159623 7159621 7159612 7159624 7157396 The manufacturer reserves the right to replace the spare parts listed above by equivalent substitutes. Page 49 User’s Manual for ION™-M17HP/19P (M-cab) For your notes: Page 50 M0145A0A.doc 8 Index 8. INDEX Abbreviations.......................................................... 7 Address of Andrew Wireless Systems GmbH....... 12 Alarms Alarm Status .................................................... 37 Bite and Alarms ............................................... 37 External Inputs........................................... 38, 39 Handling of Alarms .......................................... 37 List ................................................................... 40 Outputs ...................................................... 38, 39 RU ................................................................... 40 Status LED....................................................... 37 Andrew Solutions.................................................. 10 Health and Safety Warnings................................... 8 Block Diagram ION-M17HP/19P.............................................. 15 Cleaning the Heat Sink ......................................... 44 Commissioning General ............................................................ 34 Components Accessories ..................................................... 17 Fan-Protection Kit ............................................ 17 Interior ............................................................. 16 Connection Rules Optical Fibers................................................... 29 Optical-Fiber Cables ........................................ 29 Connections Antenna ........................................................... 28 Connector Flange ............................................ 26 Power .............................................................. 27 Contact Addresses ............................................... 11 Customer Support Addresses............................... 11 Flange Connector 5 poles ............................................................. 38 7 poles ............................................................. 38 Illustrations ........................................................... 45 Installation Electrical .......................................................... 25 Mechanical ...................................................... 19 Maintenance......................................................... 41 Mounting Fan Protection ................................................. 24 Pole (Outside).................................................. 22 Wall.................................................................. 21 Optical-Fiber Connection Protective-Tube Kit .......................................... 32 Optical-Fibre Connection Protective Plug ................................................ 30 Pin Assignment External Alarms ............................................... 39 Replacement of Fan Unit...................................... 42 Spare Parts .......................................................... 49 Specifications Electrical .......................................................... 46 Environmental and Safety................................ 48 Mechanical ...................................................... 47 Troubleshooting.................................................... 40 Grounding............................................................. 27 Page 51
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Print high-res Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : Acrobat PDFMaker 8.1 für Word Modify Date : 2011:09:05 14:32:36+02:00 Create Date : 2011:09:05 14:19:31+02:00 Metadata Date : 2011:09:05 14:32:36+02:00 Producer : Acrobat Distiller 8.1.0 (Windows) Format : application/pdf Creator : Raissa Panlilio Title : Additional information on SM2009 Document ID : uuid:0ad3efd6-5997-4b17-b3a8-2ebc5e937911 Instance ID : uuid:6b9a18a6-834c-4eb9-9d4f-7042d2a5e018 Company : Mikom GmbH Source Modified : D:20110905121838 Page Count : 52 Page Layout : OneColumn Author : Raissa PanlilioEXIF Metadata provided by EXIF.tools