Andrew Wireless System IONM17HP19P ION M Remote Unit for cellular networks User Manual Additional information on SM2009

Andrew Wireless System ION M Remote Unit for cellular networks Additional information on SM2009

User Manual

Download: Andrew Wireless System IONM17HP19P ION M Remote Unit for cellular networks User Manual Additional information on SM2009
Mirror Download [FCC.gov]Andrew Wireless System IONM17HP19P ION M Remote Unit for cellular networks User Manual Additional information on SM2009
Document ID1562036
Application ID+oMfzeXl9wiNorMZSZ3CoA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize177.76kB (2222037 bits)
Date Submitted2011-10-18 00:00:00
Date Available2012-03-31 00:00:00
Creation Date2011-09-05 14:19:31
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2011-09-05 14:32:36
Document TitleAdditional information on SM2009
Document CreatorAcrobat PDFMaker 8.1 für Word
Document Author: Raissa Panlilio

Optical Remote Unit
ION™-M17HP/19P
(M-cabinet)
User's Manual
M0145A0A
User’s Manual for
ION™-M17HP/19P (M-cab)
© Copyright 2011 CommScope, Inc.
All rights reserved.
Andrew Solutions is a trademark of CommScope, Inc.
All information contained in this manual has been revised thoroughly. Yet Andrew
Solutions accepts no liability for any omissions or faults.
Andrew Solutions reserves the right to change all hard- and software characteristics
without notice.
Names of products mentioned herein are used for identification purposes only and
may be trademarks and / or registered trademarks of their respective companies.
No parts of this publication may be reproduced, stored in a retrieval system,
transmitted in any form or by any means, electronical, mechanical photocopying,
recording or otherwise, without prior written permission of the publisher.
Andrew Wireless Systems GmbH, 05-September-2011
Page 2
M0145A0A.doc
TABLE OF CONTENTS
1. GENERAL
1.1.
USED ABBREVIATIONS
1.2.
HEALTH AND SAFETY WARNINGS
1.3.
ABOUT ANDREW SOLUTIONS
10
1.4.
INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT
11
2. INTRODUCTION
13
2.1.
PURPOSE
13
2.2.
THE ION-M17HP/19P (INTELLIGENT OPTICAL NETWORK; MMR)
13
3. FUNCTIONAL DESCRIPTION
15
3.1.
GENERAL
15
3.2.
3.2.1.
3.2.2.
3.2.3.
COMPONENTS OF THE ION-M17HP/19P REMOTE UNIT
Components Inside the Unit
Fan-Protection Kit
Accessories
16
16
17
17
4. COMMISSIONING
19
4.1.
4.1.1.
4.1.2.
4.1.3.
4.1.4.
MECHANICAL INSTALLATION
General
Wall-Mounting Procedure
Pole-Mounting Procedure
Mounting of Fan Protection
19
19
21
22
24
4.2.
4.2.1.
4.2.2.
4.2.3.
4.2.4.
ELECTRICAL INSTALLATION
General
Connections
Grounding
Power Connection
25
25
26
27
27
4.3.
CONNECTION OF THE ANTENNA CABLES
28
4.4.
4.4.1.
4.4.2.
OPTICAL FIBER CABLE CONNECTION RULES
Protective Plug
Protective-Tube Kit
29
30
32
4.5.
COMMISSIONING
34
Page 3
User’s Manual for
ION™-M17HP/19P (M-cab)
5. ALARMS
37
5.1.
BITE AND ALARMS
37
5.2.
HANDLING OF ALARMS
37
5.3.
ALARM STATUS
37
5.4.
STATUS LED ALARMS
37
5.5.
EXTERNAL ALARM INPUTS AND OUTPUTS
38
5.6.
TROUBLESHOOTING
40
6. MAINTENANCE
41
6.1.
GENERAL
41
6.2.
REPLACING THE FAN UNIT
42
6.3.
CLEANING THE HEAT SINK
44
7. APPENDIX
45
7.1.
ILLUSTRATIONS
45
7.2.
7.2.1.
7.2.2.
7.2.3.
SPECIFICATIONS
Electrical Specifications
Mechanical Specifications
Environmental and Safety Specifications
46
46
47
48
7.3.
SPARE PARTS
49
8. INDEX
Page 4
51
M0145A0A.doc
FIGURES AND TABLES
figure 3-1 Configuration of an ION-M17HP/19P Remote Unit................................... 15
figure 3-2 Remote Unit, front side, fully RF equipped ............................................... 16
figure 3-3 Remote Unit, rear side, fully RF equipped................................................ 16
figure 4-1 Wall mounting, (metric dimensions).......................................................... 21
figure 4-2 Pole-mounting kit...................................................................................... 22
figure 4-3 Pole mounting (metric dimensions) .......................................................... 23
figure 4-4 Mounting procedure for fan protection, (metric dimensions)..................... 24
figure 4-5 Connector flange of ION-M17HP/19P ...................................................... 26
figure 4-6 Grounding bolt with loosened hex nut ...................................................... 27
figure 4-7 Grounding bolt, schematic view................................................................ 27
figure 4-8 AC mains plug .......................................................................................... 28
figure 4-9 Protective-plug assembly ......................................................................... 30
figure 4-10 Tube-kit installation................................................................................. 33
figure 5-1 Flange connector, 5 poles ........................................................................ 38
figure 5-2 Flange connector, 7 poles ........................................................................ 38
figure 5-3 Alarm inputs and outputs, standard .......................................................... 39
figure 7-1 Installation drawing................................................................................... 45
table 1-1 List of international contact addresses....................................................... 12
table 4-1 Specified torques ....................................................................................... 20
table 5-1 Status LED alarms..................................................................................... 38
Page 5
User’s Manual for
ION™-M17HP/19P (M-cab)
For your notes:
Page 6
M0145A0A.doc
1 General
1. GENERAL
1.1. USED ABBREVIATIONS
3GPP
AC/DC
AIMOS
ALC
BITE
BTS
CE
CD
CPD
DL
DoC
EDGE
EN
EP
ESD
ETS
EU
GSM
GND
GUI
ICP3
ID No
ION
IP
ISO
LED
LMT
LTE
MIMO
MS
MU
NF
OTRx
PG
PIM
R&TTE
Rev
RF
RU
RX
SNMP
TS
TX
UL
UMTS
UPS
VSWR
WCDMA
WDM
3rd Generation Partnership Project
Alternating current / Direct Current
Andrew Integrated Management and Operating System
Automatic Level Control
Built-In Test Equipment
Base Transceiver Station
"Conformité Européenne" ("European Conformity")
Compact Disk
Channel Power Detection
Downlink
Declaration of Conformity
Enhanced Data Rates for GSM Evolution
European Norm
Extension Port
Electrostatic Discharge
European Telecommunication Standard
Extension Unit
Global System for Mobile Communication
Ground
Graphical User Interface
rd
Intercept Point 3 order
Identification Number
Intelligent Optical Network
Ingress Protection
International Organization for Standardization
Light Emitting Diode
Local Maintenance Terminal
Long Term Evolution
Multiple Input Multiple Output
Mobile Station
Main Unit
Noise Figure
Optical Transceiver = SRMU (Subrack Master Unit)
Packing Gland
Passive Intermodulation
Radio & Telecommunications Terminal Equipment
Revision
Radio Frequency
Remote Unit
Receiver
Simple Network Management Protocol
Technical Specification
Transmitter
Uplink
Universal Mobile Telecommunication System
Uninterruptible Power Supply
Voltage Standing Wave Ratio
Wideband Code Division Multiple Access
Wavelength Division Multiplex
Page 7
User’s Manual for
ION™-M17HP/19P (M-cab)
1.2. HEALTH AND SAFETY WARNINGS
1. Only suitably qualified personnel is allowed to work on this unit and only after
becoming familiar with all safety notices, installation, operation and maintenance
procedures contained in this manual.
2. Read and obey all the warning labels attached to the unit. Make sure that the
warning labels are kept in a legible condition and replace any missing or
damaged labels.
3. Obey all general and regional installation and safety regulations relating to work
on high voltage installations, as well as regulations covering correct use of tools
and personal protective equipment.
4. Keep operating instructions within easy reach and make them available to all
users.
5. It is the responsibility of the network provider to implement prevention measures
to avoid health hazards which may be associated to radiation from the antenna(s)
connected to the unit.
6. Note for a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.
7. Make sure, access is restricted to qualified personnel.
8. Only licence holders for the respective frequency range are allowed to operate
this unit.
9. Corresponding local particularities and regulations must be observed. For national
deviations please refer to the respective documents included in the manual CD
delivered.
10. Use this equipment only for the purpose specified by the manufacturer. Do not
carry out any modifications or fit any spare parts which are not sold or
recommended by the manufacturer. This could cause fires, electric shock or other
injuries.
11. Due to power dissipation, the repeater may reach a very high temperature. Do not
operate this equipment on or close to flammable materials.
Page 8
M0145A0A.doc
1 General
12. Before opening the unit, disconnect mains.
13. ESD precautions must be observed! Before commencing maintenance work, use
the available grounding system to connect ESD protection measures.
14. This unit complies with European standard EN60950.
15. Make sure the repeater settings are according to the intended use (see also
product information of manufacturer) and regulatory requirements are met.
16. Although the repeater is internally protected against overvoltage, it is strongly
recommended to earth the antenna cables close to the repeater’s antenna
connectors for protection against atmospheric discharge.
17. Laser radiation! Do not stare into the beam; do not view it directly or with optical
instruments.
Page 9
User’s Manual for
ION™-M17HP/19P (M-cab)
1.3. ABOUT ANDREW SOLUTIONS
Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading
manufacturer of coverage equipment for mobile radio networks, specializing in high
performance, RF and optical repeaters. Our optical distributed networks and RF
repeater systems provide coverage for every application: outdoor use, indoor
installations, tunnels, subways and many more.
Andrew Wireless Systems GmbH has unparalleled experience in providing RF
coverage and capacity solution for wireless networks in both indoor and outdoor
environment and belongs to Andrew Solutions, a CommScope Company.
Andrew Solutions is the foremost supplier of one-stop, end-to-end radio frequency
(RF) solutions. Our products are complete solutions for wireless infrastructure from
top-of-the-tower base station antennas to cable systems and cabinets, RF site
solutions, signal distribution, and network optimization.
Andrew Solutions has global engineering and manufacturing facilities. In addition, it
maintains field engineering offices throughout the world.
We operate a quality management system in compliance with the requirements of
ISO 9001. All equipment is manufactured using highly reliable material. In order to
ensure constant first-rate quality of the products, comprehensive quality monitoring is
conducted at all fabrication stages. Finished products leave the factory only after a
thorough final acceptance test, accompanied by a test certificate guaranteeing
optimal operation.
) Note:
Exceptions of and national deviations from this intended use may be
possible. To observe corresponding local particularities and
regulations, please refer to the respective documents (also in
national language) which are included in the manual CD delivered.
To make the most of this product, we recommend you carefully read the instructions
in this manual and commission the system only according to these instructions.
For technical assistance and support, please also contact the local office or Andrew
Solutions directly at one of the addresses listed in the following section.
Page 10
M0145A0A.doc
1 General
1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT
Americas:
Canada
United States
Andrew Solutions Canada
Andrew Solutions,
Andrew LLC, A CommScope Company
Mail
620 North Greenfield Parkway
Garner, NC 27529
U.S.A.
Mail
620 North Greenfield Parkway
Garner, NC 27529
U.S.A.
Phone
+1-905-878-3457 (Office)
+1-416-721-5058 (Mobile)
Phone
+1-888-297-6433
Fax
+1-905-878-3297
Fax
+1-919-329-8950
E-mail
Peter.Masih@commscope.com,
WIsupport.us@commscope.com
E-mail
WIsupport.us@commscope.com
Brazil & South America
Mexico, Central America &
Caribbean region
CommScope Cabos do Brasil Ltda.
Andrew Corporation Mexico,
SA DE CV
Mail
Av. Com. Camilo Julio 1256
Zonal Industrial CP 597
Sorocaba SP 18086-000
Brazil
Mail
Av. Insurgentes Sur 688, Piso 6
Col. Del Valle, CP: 03100
Mexico City
Mexico
Phone
+ 55-15-9104-7722
Phone
+52-55-1346-1900 (Office)
+52-1-55-5419-5260 (Mobile)
Fax
+ 55-15-2102-4001
Fax
+52-55-1346-1901
E-mail
WIsupport@commscope.com
E-mail
WIsupport@commscope.com
APAC Countries:
China, India and Rest of Asia
Andrew International Corporation
Australia & New Zealand
Andrew Corporation (Australia) Pty Ltd.
Mail
Room 915, 9/F
Chevalier Commercial Centre
8 Wang Hoi Rd
Kowloon Bay
Hong Kong
Mail
Unit 1
153 Barry Road
Campbellfield
VIC 3061
Australia
Phone
+852-3106-6100
Phone
+613-9300-7969
Fax
+852-2751-7800
Fax
+613-9357-9110
E-mail
WIsupport.China@commscope.com
E-mail
WIsupport.Australia@commscope.com
Page 11
User’s Manual for
ION™-M17HP/19P (M-cab)
Europe:
United Kingdom
France
Andrew Solutions UK Ltd
CommScope France
Mail
Unit 15, Ilex Building
Mulberry Business Park
Fishponds Road
Wokingham Berkshire
RG41 2GY
England
Mail
Immeuble Le Lavoisier
4, Place des Vosges
92052 Courbevoie
France
Phone
+44-1189-366-792
Phone
+33-1 82 97 04 00
Fax
+44-1189-366-773
Fax
+33-1 47 89 45 25
E-mail
WIsupport.uk@commscope.com
E-mail
WIsupport@commscope.com
Germany
Czech Republic
Andrew Wireless Systems GmbH
Andrew Solutions Czech Republic
C-Com, spol. s r.o
Mail
Industriering 10
86675 Buchdorf
Germany
Mail
U Moruší 888
53006 Pardubice
Czech Republic
Phone
+49-9099-69-0
Phone
+420-464-6280-80
Fax
+49-9099-69-930
Fax
+420-464-6280-94
E-mail
WIsupport@commscope.com
E-mail
WIsupport@commscope.com
Austria
Switzerland
Andrew Wireless Systems (Austria) GmbH
Andrew Wireless Systems AG
Mail
Weglgasse 10
2320 Wien-Schwechat
Austria
Mail
Tiergartenweg 1
CH-4710 Balsthal
Switzerland
Phone
+43-1706-39-99-10
Phone
+41-62-386-1260
Fax
+43-1706-39-99-9
Fax
+41-62-386-1261
E-mail
WIsupport.austria@commscope.com
E-mail
WIsupport.ch@commscope.com
Italy
Spain and Portugal
Commscope Italy S.r.l., Faenza, Italy
Andrew Solutions España S.A.
A Commscope Company
Mail
Via Mengolina, 20
48018 Faenza (RA)
Italy
Mail
Avda. de Europa, 4 - 2ª pta.
Parque Empresarial La Moraleja
28108 Alcobendas (Madrid)
Spain
Phone
+39-0546-697111
Phone
+34-91-745-20 40
Fax
+39-0546-682768
Fax
+34-91-661-87 02
E-mail
WIsupport.italia@commscope.com
E-mail
WIsupport.iberia@commscope.com
table 1-1 List of international contact addresses
Page 12
M0145A0A.doc
2 Introduction
2. INTRODUCTION
2.1.
PURPOSE
Cellular telephone systems transmit signals in two directions between base
transceiver station (BTS) and mobile stations (MS) within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor
applications, topological conditions or distance from the transmitter, extension of the
transmission range can be achieved by means of an optical distribution system.
Such a system contains an optical Master Unit and several Remote Units. The
number of the Remote Units depends on the hardware and software configuration.
The Remote Units are connected to the Master Unit with optical links. The optical
loss must be less than 10 dB inclusive optical couplers or splitters.
The Master Unit is the connection to the base transceiver stations. The configuration
of a Master Unit depends on the number of the Remote Units and the frequency
range.
WDM (Wave Division Multiplex) filters are integrated in the optical modules. For the
UL, a wavelength within 1540 nm – 1562 nm is used. For the DL, a wavelength of
1310 ±20 nm is used. The maximum output power for the UL and DL is 5.7 mW.
2.2.
THE ION-M17HP/19P (INTELLIGENT OPTICAL NETWORK; MMR)
The ION-M17HP/19P is a multi-band multi-operator Remote Unit with various
Extension Units (EUs). It is used in conjunction with a Master Unit (MU) in the ION
optical distribution system. This system transports multiple frequency bands
simultaneously (PCS 1900 MHz, AWS 1700/2100 MHz and 700 MHz EU), providing
a cost-effective solution for distributing capacity from one or more base stations.
The ION-M17HP/19P transports signals on the RF layer in a very inexpensive
manner. This means that multiple operators and multiple technologies are moved
simultaneously from a cluster of base stations to a remote location over the same
fiber.
The ION optical distribution system is a cost-effective coverage solution for dense
urban areas, tunnels, subway, airports, convention centers, high-rise buildings and
other locations where physical structures increase path loss. It has been specifically
designed to reduce zoning problems and to provide homogeneous coverage. The
compact, mechanical design is specifically architected to mount inside of poles or
along side structures in such a way that it has a minimal visual impact.
Page 13
User’s Manual for
ION™-M17HP/19P (M-cab)
The ION-M17HP/19P is available in a multi-band configuration supporting 1900 MHz
and 1700/2100 MHz in parallel and with extension option 700 MHz additionally. It has
been specifically tested and optimized for GSM, EDGE, CDMA2000, EV-DO,
WCDMA, HSPA+ and OFDM. Furthermore it is provisioned for future improvements
to the modulation and frequency bands.
The ION is easily set-up and supervised via a graphical user interface (GUI). Remote
Units can be commissioned through the use of built-in test equipment. An autolevelling function compensates for the optical link loss making installation easy and
quick. The entire system may be monitored remotely via an Andrew OMC. This is a
comprehensive management platform with SNMP protocol and X.733 standard
implemented. Should a sophisticated interface not be required, the Master Unit can
be directly connected to the alarm interface of a base station via relay alarming.
Features at a glance
• Multi-band, multi-operator support
• Reduced visual impact form factor
• Efficient, high power amplifier
• Single fiber for multiple bands and multiple remotes
• Comprehensive operations and management system for configuration and alarming
• OMC with SNMP according to X.733 standard
• 3GPP TS25.143/TS25.106/ TS36.143/TS36.106 and 3GPP2C.S0051-0 compliant
• Easy installation and commissioning
Page 14
M0145A0A.doc
3 Functional Description
3. FUNCTIONAL DESCRIPTION
3.1.
GENERAL
The following figure shows the configuration of an ION-M17HP/19P Remote Unit.
Optical Module
WDM
UL/DL
OTRX
DL
UL
728-894MHz
935-941MHz
1805-2170MHz
698-849MHz
896-902MHz
1710-2130MHz
from / to Master Unit
1900 MHz
Power Amplifier
1930 - 1995 MHz
+28 VDC
I²C
Buffer
Crossband coupler
(part of duplexer unit)
26
I²C
+28 VDC
Duplexer unit
With distribution unit
DC
X11
X6
3 colors LED
Fan
X3
2100 MHz
4 external alarms
inputs
4 external alarms
outputs
+28 VDC output
Probe (nd)
X12
Power Amplifier
X12
Control Unit RCM161
Antenna
port
X12
Buffer
RS232
X12
I²C
Ext. Board
Splitter (part of
duplexer unit)
+28 VDC
2100 MHz
Combiner (part
of duplexer unit)
2110 – 2155 MHz
Power Amplifier
Buffer
I²C
100..240VAC
I²C
+28 VDC
Buffer
Power Supply Unit AC
(100 - 240 VAC)
1710 – 1755 MHz
1850 – 1910 MHz
+28 VDC
RS485
Ext.- Connector
Pin 1: 700MHz DL
Pin 2: 700MHz UL
Pin 3: n.c.
Pin 4: n.c.
Pin 5: n.c.
Pin 6: RS485 +
Pin 7: RS485 -
E1187B000
figure 3-1 Configuration of an ION-M17HP/19P Remote Unit
Page 15
User’s Manual for
ION™-M17HP/19P (M-cab)
3.2.
COMPONENTS OF THE ION-M17HP/19P REMOTE UNIT
The actual configuration of the Remote Unit can be seen at the configuration list
which is part of the delivery.
3.2.1. Components Inside the Unit
The following figures show exemplary views of a fully equipped ION-M17HP/19P
Remote Unit – except for the fan housing without cover – to illustrate the individual
components.
Air inlet
Air outlet
Amplifier AWS 1
Amplifier AWS 2
Amplifier PCS
Optical module
PSU
Distribution unit
Duplexer
PCS 1900 /
AWS 1700/2100
figure 3-2 Remote Unit, front side,
fully RF equipped
Page 16
figure 3-3 Remote Unit, rear side,
fully RF equipped
M0145A0A.doc
3 Functional Description
3.2.2. Fan-Protection Kit
In order to protect the fan unit (e.g. against rain), a protective cover to be mounted
over the air inlet is delivered with the unit. For more details see section 4.1.4
Mounting of Fan Protection.
Mounting of the fan-protection kit is only mandatory for outdoor applications,
however, not mandatory for indoor applications.
3.2.3. Accessories
For the accessories available for the Remote Unit, e.g. overcoat housing, connecting
box or iso-trafo kit, a separate manual is available.
Page 17
User’s Manual for
ION™-M17HP/19P (M-cab)
For your notes:
Page 18
M0145A0A.doc
4 Commissioning
4. COMMISSIONING
4.1.
MECHANICAL INSTALLATION
4.1.1. General
Read the health and safety warnings in section 1.2 Health and Safety Warnings.
1. Do not install the unit in a way or at a place where the specifications
outlined in the Environmental and Safety Specifications leaflet of the
supplier are not met.
2. It is recommended only to use the mounting hardware delivered by the
supplier. If different mounting hardware is used, the specifications for
stationary use of the Remote Unit must not be exceeded.
) Note:
Exceeding the specified load limits may cause the loss of warranty!
3. The unit is considerably heavy. Make sure that a suitable mounting surface
is used. Ensure there is adequate manpower to handle the weight of the
system.
4. Due to power dissipation, the Remote Unit may reach a very high
temperature. Ensure sufficient airflow for ventilation as specified in the
individual mounting procedures.
5. When connecting and mounting the cables (RF, optical, mains, ...) ensure
no water can penetrate into the unit through these cables.
6. Also observe all additional rules or restrictions regarding mounting that
depend on the type of Remote Unit. For details refer to section 7.2.2
Mechanical Specification. Install the unit vertically with the fan unit at the
top. A maximum tilt angle of 25° from a vertical position must be kept, as in
the following illustrations:
Page 19
User’s Manual for
ION™-M17HP/19P (M-cab)
7. A spacing of 40 mm (1.58 inch) around the unit is required.
8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two
lid openings (one for the air inlet and the other for the air outlet) have to be
provided. Do not block these air inlets and outlets when mounting the
Remote Unit. The size of each opening must equal at least 12 x 12 cm (144
cm2). Make sure, too, there is no thermal short circuit between the air inlet
and air outlet.
If any different or additional mounting material is used, ensure that the mounting
remains as safe as the mounting designed by the manufacturer. Ensure that the
static and dynamic strengths are adequate for the environmental conditions of the
site. The mounting itself must not vibrate, swing or move in any way that might cause
damage to the Remote Unit.
Specified torques have to be observed for certain mounting procedures according to
the following table:
Type
Thread
Specified torques
Tallow-drop Hex
Spacing
PG
PG
screws
nuts
bolts
(plastic) (aluminium)
M4
M8
M4
M8
PG 13.5 PG 29
3.3 Nm
27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm
table 4-1 Specified torques
) Note:
To avoid damage when mounting the unit, always make sure that
the M8 washers (DIN9021 or DIN125 depending on the mounting kit)
are placed behind and in front of the mounting drillings of the unit.
The mounting procedures for a stand-alone Remote Unit without optional
accessories are described and illustrated in the following sections. For further
information regarding special mounting procedures including mounting of accessory
equipment, please see separate manual.
Page 20
M0145A0A.doc
4 Commissioning
4.1.2. Wall-Mounting Procedure
Check the suitability of the wall-mounting kit and the wall.
Mark the position of the drilling
holes (for measurements refer to
figure 4-1 Wall mounting). Drill
four holes at the marked positions
and insert dowels *.
Wall mounting with active cooling kit
4.0
0.50
122 ± 0.50
80 ± 0.50
18
Use a cap nut or lock nut to screw
the four dowel screws into the
dowels and put the distance tubes
over the screws.
796 ± 1.00
Hang the mounting brackets of the
Remote Unit into the screws, and
fasten them immediately using the
washers and nuts.
Ensure that there is free access to
the electrical connections as well
as to the cabinet. The approved
bending radius of the connected
cables must not be exceeded.
Mains supply
G0946Z0
figure 4-1 Wall mounting, (metric dimensions)
* The dowels are not part of the delivery since the suitable type depends on the on-site conditions
(material of wall). Therefore, use dowels that are appropriate for the mounting surface.
Page 21
User’s Manual for
ION™-M17HP/19P (M-cab)
4.1.3. Pole-Mounting Procedure
Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a
column or other similar structures. Additional hardware must be used for this type of
installation. Such a pole-mounting kit could include two threaded rods M8, two
U-beams and mounting material like bolts and nuts.
figure 4-2 Pole-mounting kit
Use the screw bands to fasten the two U-beams to the pole as illustrated in figure
4-3 Pole mounting.
) Note:
When fastening the U-beams make sure that they are installed
congruently and not at an angle to each other. To determine the
distance between the beams refer to 4.1.2 Wall-Mounting Procedure
for measurements.
Hang the mounting brackets of the Remote Unit into the threaded bolts of the
U-beam, and fasten them immediately using the washers and nuts.
Ensure that there is free access to the electrical connections as well as to the
cabinet. The approved bending radius of the connected cables must not be
exceeded.
Page 22
M0145A0A.doc
4 Commissioning
TESPA screw band,
stainless, 11 mm
Optical
Remote Unit
Washer DIN 125
Form B Ø 8.0
Lock washer for M8.0 DIN 127
A2 Form B
Hexagon nut M8
DIN 934
Ø140
Ø40
Lock for folding
screw band ES 119
Pole
Pole
Pole-mounting
bracket
G0764M6
figure 4-3 Pole mounting (metric dimensions)
Page 23
User’s Manual for
ION™-M17HP/19P (M-cab)
4.1.4. Mounting of Fan Protection
Since the fan protection is required for the outdoor usage of a stand-alone Remote
Unit, the mounting of this optional equipment is also described in this manual.
To install the protective cover of the fan protection kit, first unscrew the four
screws with the respective lock washers from the cover of the air inlet of the
Remote Unit, and instead, screw in the four spacing bolts M4.0x30 with the four
lock washers M4.0 DIN125 that are part of the fan protection kit.
Place the protective cover into the right position by fitting its four bore holes over
the spacing bolts and fasten it using the original lock washers and screws of the
Remote Unit. (These lock washers and screws are also part of the fan protection
kit and can be used as spare parts in case of loss.)
remove the screw
and the lock washer!
2x M4.0x8 fillister-head screws
remove the screw
and the lock washer!
2x M4.0x8
fillister-head screws
2x lock washers
2x lock washers
2x washers
2x M4.0x8
fillister-head screws
AIR STREAM
2x M4.0x30
spacing bolts
1x rain protective cover
2x lock washers
2x washers
2x M4.0x8
fillister-head screws
2x M4.0x8
fillister-head screws
156
152
171
2x lock washers
20
remove the screw
and the lock washer!
G0496MF
figure 4-4 Mounting procedure for fan protection, (metric dimensions)
Page 24
M0145A0A.doc
4 Commissioning
4.2.
ELECTRICAL INSTALLATION
4.2.1. General
Read the health and safety warnings in section 1.2 Health and Safety Warnings.
1. This unit contains dangerous voltages. Loss of life, severe personal injury or
property damage can be the result if the instructions contained in this manual are
not followed.
2. Ground the unit before connecting power supply. A grounding bolt is provided on
the cabinet to connect the ground-bonding cable.
3. Although the Remote Unit is internally protected against over-voltage, it is
strongly recommended to earth the antenna cables close to the antenna
connectors of the Remote Unit for protection against atmospheric discharge. In
areas with strong lightning it is highly recommended to insert additional lightning
protection.
4. If the mains connector of the Remote Unit is not easily accessible, a disconnect
device in the mains circuit must be provided within easy reach.
5. Before connecting or disconnecting the mains connector at the Remote Unit,
ensure that mains supply is disconnected.
6. Make sure that an appropriate circuit breaker and an over-current limiting device
are connected between mains and Remote Unit.
7. A connection of mains supply to a power socket requires the power socket to be
nearby the Remote Unit.
8. Incorrectly wired connections can destroy electrical and electronic components.
9. To avoid corrosion at the connectors caused by electrochemical processes, the
material of the cable connectors must not cause a higher potential difference than
0.6 V (see electrochemical contact series).
10. Use an appropriate torque wrench for the coupling torque of N-type connectors
(2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna connectors.
For example, use torque wrench of item no. 244379 available from the Andrew ecatalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This
might cause damage to the connector and lead to a malfunction of the Remote
Unit.
11. Use a voltage limiting device for unstabilized electric networks that frequently
generate spikes.
Page 25
User’s Manual for
ION™-M17HP/19P (M-cab)
12. The unit complies with the surge requirement according to EN 61000-4-5 (fine
protection); however, it is recommended to install an additional medium (via local
supply connection) and/or coarse protection (external surge protection),
depending on the individual application, in order to avoid damage caused by
overcurrent.
13. Observe the labels on the front panels before connecting or disconnecting any
cables.
4.2.2. Connections
Mains
connector
RS485
connector
Extension Unit
connector
External
alarm input
Alarm
output
Status
LED
Optical-fibre
connector
N-antenna
connector Mobile
Grounding bolt
figure 4-5 Connector flange of ION-M17HP/19P
Page 26
M0145A0A.doc
4 Commissioning
4.2.3. Grounding
Grounding must be carried out. Connect an earth-bonding cable to the grounding
connection provided at the outside of the Remote Unit (see section 4.2.2
Connections). Do not use the grounding connection to connect external devices.
figure 4-6 Grounding bolt with
loosened hex nut
figure 4-7 Grounding bolt, schematic view
After loosening the hex nut, connect the earth-bonding cable between the two
washers as illustrated in the figures above. Then, fasten all parts again with the hex
nut.
4.2.4. Power Connection
Before connecting electrical power to the RU, the system must be grounded as
described in the previous section.
Mains power must be connected at the mains connector of the unit (see section 4.2.2
Connections).
The power supply plug is part of the delivery. The correct wiring of the power supply
plug is as follows:
Page 27
User’s Manual for
ION™-M17HP/19P (M-cab)
figure 4-8 AC mains plug
For the AC power supply connection, a minimum cross section of 1.5
mm2 is required. Each wire must observe the applicable national
regulations regarding loop impedance, voltage drop, and methods of
installation. Make sure to connect the correct voltage to the unit.
) Note:
Do not connect or disconnect the power cord at the mains connector
while power is on. Turn off mains power * before connecting the
power cord at the Remote Unit, then, engage mains again.
Mains power must be interruptible with an external mains breaker. For the mains breaker,
observe the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed,
i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240Volt service.
4.3.
CONNECTION OF THE ANTENNA CABLES
The Remote Unit has N-type antenna connectors. Please refer to section 4.2.2
Connections for its location. Refer to the corresponding documentation of the
connector manufacturer for mounting the cable connectors.
The bending radius of the antenna cables must remain within the given
specifications.
Consider the type of cable best suited for the antenna. Remember that a cable with
higher loss is less expensive but impairs performance.
Page 28
M0145A0A.doc
4 Commissioning
Do not use a tool (e.g. pair of pliers) to tighten the N-type antenna connectors
as it might cause damage to the connector and lead to a malfunction of the
Remote Unit. It is sufficient to tighten the N-type antenna connectors by
hand.
) Note: Directly connect the base station signal to the Master Unit using a
coaxial cable to avoid coupling another signal into the system in the
DL direction than the single wanted signal transmitted by the base
station.
4.4.
OPTICAL FIBER CABLE CONNECTION RULES
Optical signals are transmitted by use of optical fibers. The optical fiber is a singlemode fiber. Type is E9/125 µm with the following minimum requirements.
Attenuation: <0.36 dB / km @ 1310 nm
Dispersion: <3.5 ps / nm km @ 1310 nm
<0.26 dB / km @ 1550 nm
<18.0 ps / nm km @ 1550 nm
Follow the procedure below before connecting the fiber cables to ensure optimized
performance. These procedures must be carried out carefully:
1. Remove fiber-optic protective caps.
2. Clean the end of the fiber-optic cable that will be inserted in the optical connectors
on the donor interface box with high-grade alcohol and lint-free cotton cleaning
swabs.
3. Blow out the laser receptacle with clean and dry compressed air to remove any
particulate matter.
4. Connect the fiber-optic cables by inserting the cable end into the laser receptacle
and aligning the key (on the cable end) with the keyed slot.
5. Measure attenuation and reflection with an appropriate measuring instrument. For
pigtails, a total value of < 0.4 dB (measured to a reference plug) can be assumed
due to the dead zone of the reflectometer. These measurements must be made
with a sufficient length of optical fiber, at the input and output of the device which
has to be measured.
6. Do not use any index matching gels or fluids of any kind in these connectors.
Gels are intended for laboratory use and attract dirt in the field.
Observe the following guidelines when connecting the optical fibers:
ƒ
Do not bend the fiber-optic cable in a tight radius (< 4 cm) as this may cause
cable damage and interrupt transmission.
ƒ
The specified bending radius of the optical fibers must not be exceeded.
ƒ
The pigtails for the connection between Master and Remote Unit must have a
sufficient length. A protection for the feeding into units must be given.
Page 29
User’s Manual for
ION™-M17HP/19P (M-cab)
ƒ
System attenuation and attenuation of optical components must be determined.
ƒ
Fiber-cable connectors have to be of the same type (E2000APC) as the
connectors used for the unit. The fiber-optic cables are connected to the optical
transceiver.
ƒ
Angled connectors are not compatible with straight optical connectors;
non-compatibility of connectors will result in permanent damage to both
connectors.
) Note:
Care should be taken when connecting and disconnecting
fiber-optic cables. Scratches and dust significantly affect system
performance and may permanently damage the connector. Always
use protective caps on fiber-optic connectors not in use.
) Note:
In general, optical fibers do not need special protective measures.
However, protection against environmental influences e.g. rodents
and humidity must be considered.
4.4.1. Protective Plug
Connection:
A protective plug is provided for the connection of the fibre-optic cables.
figure 4-9 Protective-plug assembly
) Note:
Page 30
Only high-quality connectors must be used for this type of plug.
Qualified brands are Diamond or Huber & Suhner.
M0145A0A.doc
4 Commissioning
For plug assembly, observe the following instruction:
1. Pass one or two contacts through the
backshell and the clamp ring.
2. Place the contact(s) on the lower insulation body by pushing the groove of the
contact into the cavity. If there is only one contact, cavity A must be used. *
3. Then, mount the upper insulation body on the lower insulation body. **
Upper insulation body
Cavity B
Cavity A
4. Bring the insulator into the plug. The narrow groove of the insulator must be fitted
into the stamp of the plug.
**
To release the contact for disassembling, push the inner snap to the side and pull the contact out.
To release upper and lower insulation bodies for disassembling, use a small screwdriver and
carefully open the snap-connections at the left and the right side of the insulator without
damaging them.
5. Fasten the insulator by screwing the 6. Place the appropriate seal parts (with
backshell tight onto it. Use a spanner
one groove for one contact or two
with opening 32 to screw the
grooves for two contacts) over the
backshell tight (no gap).
cable(s) and push them into the
backshell.
No gap
Seals with
one groove
Page 31
User’s Manual for
ION™-M17HP/19P (M-cab)
7. Bring the plastic ring over the cable(s), push it into the backshell and compress
the seals and plastic ring by screwing the clamp ring tight (no gap) using a
spanner with opening 20. ***
Screw tight until gap is closed
8. Connect the plug to the optical-fibre 9. To lock the connector, push the black
connector of the Remote Unit, again
locking ring forward.****
by fitting a stamp on the plug into the
groove of the connector.
Groove
Push forward to lock, pull
back to free connection
*** For disassembling, release the clamping ring and remove the seals and the plastic ring first.
**** Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The
locking ring has to be pushed forward to lock the connector and pulled back to free the
connection.
4.4.2. Protective-Tube Kit
As additional protection for the optical fibres, this connector type can be
supplemented by a special tube kit. To fasten the tube correctly, first unscrew the
clamp ring (if already installed) of the original plug kit.
Then, proceed according to the following instruction:
Page 32
M0145A0A.doc
4 Commissioning
Protective plug
Fiber cable
Ring 3/4
Reducer
Screw the reducer to
the protective plug
backshell without any
gap!
Coupling
Place the appropriate seal
parts (with) one groove for
one contact or two grooves
for two contacts) over the
cable(s) and push them into
the backshell!
Protective tube
Push the fiber-optic cable carefully
through the tube until it comes out
at the other end.
G1055M0
figure 4-10 Tube-kit installation
Page 33
User’s Manual for
ION™-M17HP/19P (M-cab)
4.5. COMMISSIONING
Read the health and safety warnings in section 1.2 Health and Safety Warnings.
Keep these guidelines in mind before continuing to the instructions for
commissioning:
Do not operate the Remote Unit without terminating the antenna connectors.
The antenna connectors may be terminated by connecting them to their
respective antennas or to a dummy load.
Only qualified personnel should carry out the electrical, mechanical,
commissioning, and maintenance activities that require the unit to be powered
on when open.
Do not damage the warranty labels on the devices. The warranty is void if the
seals are broken.
Ensure that all connections have been performed according to section 4.2.2
Connections.
Page 34
M0145A0A.doc
4 Commissioning
Commissioning an ION-M Remote Unit
Manual for Remote
Unit
Philips
screwdriver
Mounting kit
Spanner, size
13 mm
Drilling
machine
Dowels
Screw driver
Screw driver
Spanner, size
13 mm
Start
Preperation
Unpack RU, RU accessories and
mounting kit.
Mechanical installation
Fasten wall or pole mounting kit to wall or
pole.
Mechanical installation
Mount RU to mounting kit, ensure suffient
air flow and avoid thermal short circuits.
Grounding cable
Spanner 13 mm
Electrical connections
Connect grounding cable and
ground the RU.
Alarm kit
(M-cabinet)
External devices
Connect external devices to the external
in or alarm out connectors, or to the
connecting board inside the RU.
RF connection
Connect antenna cable to antenna port.
Optical connections
Mount the optical fibre with E2000 APC8°
connector into the connector. Plug the
connector into the RU.
E2000 APC8° connector
Spanner with opening 32
Mains cable
Connecting kit
Electrical connections
Connect AC power to the power cable.
Ensure there is a circuit breaker between
mains and RU.
G1055Z0
Mains
Switch mains power on.
Page 35
User’s Manual for
ION™-M17HP/19P (M-cab)
LED on?
No
Check power switch inside RU
(RUs with door).
Check mains cabling.
Check mains power.
Yes
LED status
Red
Internal Error
Change power supply (RUs with a
door).
Reduce environmental temperature.
Eliminate thermal short circuit.
Disconnect and connect mains. Fans
should run. If not, replace the fans at
RU.
MU: Change amplifier setting at MU
controller
Orange
Yellow
Yes
LED status
Red
Green
Spare RU
available?
External error
Close the door (RUs with a door).
Check externally connected devices.
Check fibre loss of optical link.
Check optical connectors.
Clean optical connectors.
Check optical output power of corresponding
OTRx at master unit.
ALC alarm: Decrease DL input power of
affected band.
VSWR alarm: Check antenna and cable.
Green
No
Contact customer
service
Finished setting up
all RUs?
No
Yes
Proceed to MU to set up the SW
Go to MU
Page 36
Output:
All RUs okay.
M0145A0A.doc
5 Alarms
5. ALARMS
5.1.
BITe AND ALARMS
The Built-In Test (BITe) concept comprises the monitoring of the power supplies, the
power amplifiers and the optical interface.
All alarms occurring can be checked via software at the Master Unit.
5.2.
HANDLING OF ALARMS
A message is transmitted to the Master Unit when the software acknowledges a valid
alarm.
A new alarm message will not be repeated if the reason for the alarm is cleared or if
the alarm continues.
A new alarm message will be generated if the alarm is interrupted for at least five
seconds after acknowledgement.
5.3.
ALARM STATUS
Refer to the corresponding software documentation of the Master Unit for details.
5.4.
STATUS LED ALARMS
For local supervision, a status LED on the connector flange of the Remote Unit gives
an indication of possible reasons for alarms. This table shows possible on-site
measures that could be checked before referring to the Master Unit alarm list.
Status LED Indication
Green
Orange
Alarms
Possible on-site measures
No alarm Æ
Status ok
Door alarm
Close the door (RUs with door).
Alarms not directly related to RU:
External alarms Check externally connected devices.
Check fibre loss of optical link.
Check optical connectors.
Optical alarm Rx Clean optical connectors.
(MU: Check optical output power of
corresponding OTRx at Master Unit).
(MU: Decrease DL input power of
ALC alarm
affected band).
Page 37
User’s Manual for
ION™-M17HP/19P (M-cab)
Red
Status LED off
Alarms directly related to RU:
Change power supply (RUs with door).
Power 28 V
Replace the affected Remote Unit.
Reduce environmental temperature.
Temperature
Eliminate thermal short circuit.
Disconnect and connect mains. Fans
Fan
should run. If not, replace the fans at
RU.
I²C
Disconnect and connect mains.
Optical alarm Tx Exchange RU.
Amplifier “Power (MU: Change amplifier setting at MU
Down”
controller).
Check power switch inside of RU (RUs
with door).
Mains
Check mains cabling.
Check mains power.
table 5-1 Status LED alarms
For the position of the status LED see section 4.2.2 Connections.
Explicit troubleshooting is available in the MU software (software manual or WEB
Interface).
5.5.
EXTERNAL ALARM INPUTS AND OUTPUTS
G1038Z0
figure 5-1 Flange connector, 5 poles
Page 38
G1038Z0
figure 5-2 Flange connector, 7 poles
M0145A0A.doc
5 Alarms
The alarm outputs (open collector output 5 V / 1 mA) are normally low. In case of an
alarm they are high active (5 V). They can be used to monitor alarms with an external
alarm indicator.
The +28 V pin (for its location see figure 5-2 Flange connector, 7 poles) is protected
by a 500 mA thermoswitch. In case of exceeding this current between pin 7 and GND
and/or in case of a failure of the VSWR module, the thermoswitch turns into a highresistive status. In this case no fuse needs to be replaced. Just wait a few minutes
until the thermoswitch reaches the normal operating temperature again.
) Note:
The manufacturer / supplier of this system accepts no liability for
damage caused by equipment connected to external outputs or by
effects from such equipment.
As accessory equipment the alarm kit is available to connect external devices to the
external alarm inputs and outputs. For the exact ID No., please refer to section 7.3
Spare Parts.
With the external alarm inputs it is possible to monitor the status of connected
devices, e.g. a UPS, via software. All alarm inputs are normally high (5 V) without
connection. The polarity (high/ low) can be set via the software at the Master Unit (for
details please see according software manual).
The device to be monitored must be connected so that the alarm contacts will be
closed in case of an alarm (I max = 8 mA). The alarm inputs are potential-free with
common ground.
Subminiature circular connectors series 712 with five and seven contacts, which are
contained in the alarm kit, can be ordered directly from the Binder Connector Group,
the manufacturer, or indirectly from Andrew Solutions. For the ID No. of the alarm kit
see section 7.3 Spare Parts.
ION-M alarm outputs
ION-M alarm inputs
+5 V
+5 V
560R
4700R
Alarm output
Alarm input
Alarm GND
Alarm GND
Alarm GND
Alarm GND
V1651A1
figure 5-3 Alarm inputs and outputs, standard
Page 39
User’s Manual for
ION™-M17HP/19P (M-cab)
5.6. TROUBLESHOOTING
The status of the Remote Unit can be checked via the Master Unit (for details please
refer to the software manual of the Master Controller). Locally, the status can be
checked at the LED, see section 5.4 Status LED Alarms.
Page 40
M0145A0A.doc
6 Maintenance
6. MAINTENANCE
6.1.
GENERAL
Read the health and safety warnings in section 1.2.
) Note:
The Remote Unit does not require preventative maintenance
measures.
) Note:
To prevent malfunctions of the cooling system due to dirt or
pollution, it is recommended to clean the heat sink at regular
intervals. These cleaning intervals depend mainly on the location
of the Remote Unit and the corresponding degree of pollution.
Maintenance of the ION-M17HP/19P should be performed by replacing only
components that are contained in this section. Take care not to unintentionally
damage the seals on the modules to maintain warranty. Please keep these
guidelines in mind during maintenance:
The spare parts list, consequently, contains only units which can be replaced without
tuning or soldering work.
) Note:
Use an appropriate packaging when sending back the unit (see
section 7.2.2 Mechanical Specifications for details). We strongly
recommend using the original packaging.
) Note:
Defective parts should only be replaced by original parts from the
supplier. All interventions inside the housing are at one’s own risk.
) Note:
Ensure the Remote Unit has been disconnected from mains during
maintenance.
) Note:
Label any unlabelled cables before disconnecting them to ensure
correct re-connection.
Maintenance procedures require appropriate tools to ensure correct handling. All
these tools can be ordered from the supplier.
) Note:
All our screws have a right-hand thread and are fastened by
turning the tool clockwise and are unscrewed by turning the tool
counter-clockwise.
Due to the design of the Remote Unit the only component recommended to be
replaced is the fan unit. For replacing any other component, please contact the
supplier.
Page 41
User’s Manual for
ION™-M17HP/19P (M-cab)
6.2.
REPLACING THE FAN UNIT
Replacement of the fan unit is not required as a preventative measure. Only if an
alarm indicates a malfunctioning of a fan must the unit be exchanged.
) Note:
Please observe that the fan unit can only be replaced as a whole.
Do not remove the fans separately.
Read the health and safety warnings in section 1.2 as well as the instructions in
section 6.1 General before starting with the replacement.
1. Switch off the Remote Unit. Make sure mains is disconnected for the
following replacement procedure. Then, proceed as follows:
2. Loosen the four tallow-drop screws
M4x8 by which the fan plate is
screwed to the cabinet. Remove the
four screws and the corresponding
washers.
3. Remove the fan unit – by putting slight
pressure on the fan plate cover – to a
position that allows access to the fan
connector and the earth-bonding
cable.
4. Unscrew the fan connector and then
disconnect the earth-bonding cable.
Fan-unit connector
Earth-bonding cable
) Note:
Page 42
To observe the specified torque of 650 Ncm for an M5 thread, use
an appropriate tool for the following screwing procedures.
M0145A0A.doc
6 Maintenance
5. To mount the new fan unit, re-connect the earth-bonding cable and the fan
connector (see step 4). Then, place the fan unit back into its original position and
fasten it tight as shown below:
6. Screw the whole fan unit to the cabinet with the four tallow-drop screws M4x8
(see step 2). In order not to exceed the specified torque of 330 Ncm, use an
appropriate tool.
Page 43
User’s Manual for
ION™-M17HP/19P (M-cab)
6.3.
CLEANING THE HEAT SINK
) Note:
Read the health and safety warnings in section 1.2 Health and
Safety Warnings as well as the instructions in section 6.1 General
before starting with the replacement procedure. Then, proceed as
follows:
1. Switch off the Remote Unit. For the following procedure ensure that mains has
been disconnected before!
2. Remove the fan plate with the fan unit 3. Use compressed air (max. 5 bar) to
from the Remote Unit as described in
blow out the heat sink from back to
section 6.2 Replacing the Fan Unit,
front:
steps 1 and 2:
Compressed air
(5 bar max.)
Brush (not metallic)
4. In case the dirt cannot be blown out completely and parts of it stick to the ribs of
the heat sink, clean the parts concerned carefully from the front using e.g. a
brush. Take care that the material is not scratched or damaged.
5. After cleaning the heat sink, mount the fan unit again according to section 6.2
Replacing the Fan Unit, step 6. Then, switch the Remote Unit back on.
Page 44
M0145A0A.doc
7 Appendix
7. APPENDIX
7.1.
ILLUSTRATIONS
figure 7-1 Installation drawing
Page 45
User’s Manual for
ION™-M17HP/19P (M-cab)
7.2.
SPECIFICATIONS
7.2.1. Electrical Specifications
Electrical
Mains power
100 Vac to 240 Vac
Power supply
max. temp., fully loaded
900 watts
Power consumption
room temp. idle
550 watts
Optical Link
Connectors
E2000/APC 8°
Optical return loss
45 dB minimum
Fiber type
Single mode E9/125 µm
Optical link budget
0 dB to 10 dB
1900 MHz
1700/ 2100 MHz
700 MHz
+3 dBm
+6 dBm
+3 dBm
Input power @ OTRx master side
composite composite
composite
Minimum BTS input power 1)
-19 dBm
-16 dBm
-19 dBm
RF Interface
1900 MHz 1700/ 2100 MHz
700 MHz
Number of connectors
Master Unit
System optimized for
33 dBm
BTS power
43 dBm
Connector
N female
Antenna Port
Output power
See band specification
of RU
Return loss
15 dB typical
1700/ 2100 MHZ (AWS)
UL 1710 MHz to 1755 MHz
Frequency range
DL 2110 MHz to 2155 MHz
Number of carriers
RF output power CDMA
46 dBm
43 dBm
40 dBm 37 dBm
per carrier 2)
46 dBm
43 dBm
40 dBm 37 dBm
UMTS
4)
46 dBm
43 dBm
40 dBm 37 dBm
LTE
Spurious emission
<-13 dBm / 1 MHz
Adjacent channel power
-48 dBc
DL output tolerance over frequency
±1.0 dB
DL output tolerance over temperature
±0.5 dB 3)
ICP3 optimized
NF optimized
UL Input ICP3
-12 dBm
-18 dBm
7 dB
4.5 dB
UL Noise figure (NF) 5)
11 dB max.
6 dB max.
DL
40 dB
40 dB
Gain
UL
40 dB
47 dB
1)
2)
Additional DL gain (22 dB) available in case of low power BTS
Applicable to single modulation mode only.
Page 46
M0145A0A.doc
7 Appendix
1900 MHz
UL
1850 to 1915 MHz
Frequency range
DL
1930 to 1995 MHz
Number of carriers
GSM
43 dBm
40 dBm
37 dBm 34 dBm
RF output
power per
CDMA
43 dBm
40 dBm
37 dBm 34 dBm
carrier 2)
UMTS
43 dBm
40 dBm
37 dBm 34 dBm
4)
LTE
43 dBm
40 dBm
37 dBm 34 dBm
Spurious emission
<-13 dBm / 1 MHz
DL output tolerance over frequency
±1 dB
DL output tolerance over temperature ±0.5 dB 3)
ICP3 optimized
NF optimized
UL Input ICP3
-12 dBm
-18 dBm
dB
4.5
dB
UL Noise figure (NF) 5)
11 dB max.
6 dB max.
DL
40 dB
40 dB
Gain
UL
40 dB
47 dB
All figures are typical values unless otherwise stated.
3)
4)
5)
With active cooling
For carrier bandwidth <5 MHz output power shall be decreased by 3 dB
Note: The noise figure (NF) stated above refers to one Remote Unit (RU) per sector. The
NF-system increases with the number of the RUs per sector. It is recommended not
to operate above four RUs per sector. With four RUs per sector, the system NF will
be increased by 6 dB.
Commands
Alarms
Supervision
System Supervision and Control
RF on/off
External control ports
Summary; Power supply; Optical UL and DL failure; Temperature
Output power on a per-channel and per-band basis (optional)
All data is subject to change without notice.
7.2.2. Mechanical Specifications
Height, width, depth *
Weight
831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in)
20 kg (44 Ib)
* Spacing required 40 mm (1.58 in) around unit
All data is subject to change without notice.
Page 47
User’s Manual for
ION™-M17HP/19P (M-cab)
7.2.3. Environmental and Safety Specifications
) Note:
For detailed information, please refer to the Environmental and
Safety Specifications leaflet of the supplier, related to ETS 300 019
(European Telecommunication Standard).
Operating temperature range
RF part
Ingress protection
Fan part
-33° C to +50° C
IP67
IP55
All data is subject to change without notice.
Page 48
M0145A0A.doc
7 Appendix
7.3.
SPARE PARTS
The following lists contain all parts available for the Remote Unit. The configuration of
the delivered unit meets the requirements of the customer and can differ depending
on the state of the delivery.
Maintenance of the ION-M17HP/19P should be performed on an FRU (Field
Replaceable Unit) basis only. Do not damage the warranty labels on the
components, as this voids the warranty.
The following spare parts lists only contain units that can be replaced without tuning
or soldering work. To replace an FRU, use the appropriate tools. Replacement tools
may be ordered from the supplier. If any FRU not contained in the following list needs
to be replaced, please contact customer service for additional instructions.
Spare Parts List of the Remote Unit ION-M17HP/19P
Designation:
ID No:
FRU
7634985
ION-M17HP/19P
Protective Plug E2000
Protective Cap E 2000
Fan Protection Kit
Fan Unit
Protective Tube Kit
Manuals for ION-M17HP/19P
7160013
7158914
7159097
7158254
7162182
7638872-00
Accessories
Wall Mounting
Wall-Mounting Kit
ISO Trafo Kit 115 V Wall Mounting
ISO Trafo Kit 230 V Wall Mounting
Connecting Box Kit Wall Mounting
Overcoat Housing Kit Wall Mounting
Pole Mounting
Pole-Mounting Kit
ISO Trafo Kit 115 V Pole Mounting
ISO Trafo Kit 230 V Pole Mounting
Connecting Box Kit Pole Mounting
Overcoat Housing Kit Pole Mounting
Alarm Kit
7158078
7159340
7158322
7159613
7159625
7157782
7159623
7159621
7159612
7159624
7157396
The manufacturer reserves the right to replace the spare parts listed above by
equivalent substitutes.
Page 49
User’s Manual for
ION™-M17HP/19P (M-cab)
For your notes:
Page 50
M0145A0A.doc
8 Index
8. INDEX
Abbreviations.......................................................... 7
Address of Andrew Wireless Systems GmbH....... 12
Alarms
Alarm Status .................................................... 37
Bite and Alarms ............................................... 37
External Inputs........................................... 38, 39
Handling of Alarms .......................................... 37
List ................................................................... 40
Outputs ...................................................... 38, 39
RU ................................................................... 40
Status LED....................................................... 37
Andrew Solutions.................................................. 10
Health and Safety Warnings................................... 8
Block Diagram
ION-M17HP/19P.............................................. 15
Cleaning the Heat Sink ......................................... 44
Commissioning
General ............................................................ 34
Components
Accessories ..................................................... 17
Fan-Protection Kit ............................................ 17
Interior ............................................................. 16
Connection Rules
Optical Fibers................................................... 29
Optical-Fiber Cables ........................................ 29
Connections
Antenna ........................................................... 28
Connector Flange ............................................ 26
Power .............................................................. 27
Contact Addresses ............................................... 11
Customer Support Addresses............................... 11
Flange Connector
5 poles ............................................................. 38
7 poles ............................................................. 38
Illustrations ........................................................... 45
Installation
Electrical .......................................................... 25
Mechanical ...................................................... 19
Maintenance......................................................... 41
Mounting
Fan Protection ................................................. 24
Pole (Outside).................................................. 22
Wall.................................................................. 21
Optical-Fiber Connection
Protective-Tube Kit .......................................... 32
Optical-Fibre Connection
Protective Plug ................................................ 30
Pin Assignment
External Alarms ............................................... 39
Replacement of Fan Unit...................................... 42
Spare Parts .......................................................... 49
Specifications
Electrical .......................................................... 46
Environmental and Safety................................ 48
Mechanical ...................................................... 47
Troubleshooting.................................................... 40
Grounding............................................................. 27
Page 51


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Tagged PDF                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Creator Tool                    : Acrobat PDFMaker 8.1 für Word
Modify Date                     : 2011:09:05 14:32:36+02:00
Create Date                     : 2011:09:05 14:19:31+02:00
Metadata Date                   : 2011:09:05 14:32:36+02:00
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Format                          : application/pdf
Creator                         : Raissa Panlilio
Title                           : Additional information on SM2009
Document ID                     : uuid:0ad3efd6-5997-4b17-b3a8-2ebc5e937911
Instance ID                     : uuid:6b9a18a6-834c-4eb9-9d4f-7042d2a5e018
Company                         : Mikom GmbH
Source Modified                 : D:20110905121838
Page Count                      : 52
Page Layout                     : OneColumn
Author                          : Raissa Panlilio
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XS5-IONM17HP19P

Navigation menu