Andrew Wireless System M7P17HP ION-M Remote Unit for cellular systems User Manual Installation Instruction

Andrew Wireless System ION-M Remote Unit for cellular systems Installation Instruction

Contents

Installation Instruction

Download: Andrew Wireless System M7P17HP ION-M Remote Unit for cellular systems User Manual Installation Instruction
Mirror Download [FCC.gov]Andrew Wireless System M7P17HP ION-M Remote Unit for cellular systems User Manual Installation Instruction
Document ID2097405
Application ID3lk453HDllp75bfmSuyz9g==
Document DescriptionInstallation Instruction
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize8.61kB (107645 bits)
Date Submitted2013-10-21 00:00:00
Date Available2014-04-10 00:00:00
Creation Date2013-08-28 17:38:17
Producing SoftwareAcrobat Distiller 9.4.6 (Windows)
Document Lastmod2013-08-28 17:38:17
Document TitleMicrosoft Word - Installation Instruction.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: FRFUTTER

Installation Instruction
The Remote Unit, Extension Unit or Master Unit has to be
mounted by proffessionel / special trained installer.
1.1. HIGH POWER RU MECHANICAL INSTALLATIONN
1.1.1. General
Read the health and safety warnings in chapter 1.3.
It is the responsibility of the installer to verify that the supporting surface will safely support the
combined load of the electronic equipment and all attached hardware and components and to ensure that
the unit is safely and securely mounted.
WARNING: IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING
SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT. The installer must verify that the
supporting surface will safely support the combined load of the electronic equipment and all attached
hardware and components. The screws and dowels (wall anchors) used should also be appropriate for
the structure of the supporting wall.
1. Do not install the unit in a way or at a place where the specifications outlined in the
Environmental and Safety Specifications leaflet of the supplier are not met.
2. It is recommended to use the mounting hardware delivered by the supplier only. If different
mounting hardware is used, the specifications for stationary use of the Remote Unit must not
be exceeded.
 Note:
3.
Exceeding the specified load limits may cause the loss of warranty!
The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure
there is adequate manpower to handle the weight of the system.
4. Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure
sufficient airflow for ventilation.
5. When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can
penetrate into the unit through these cables.
6. Also observe all additional rules or restrictions regarding mounting that depend on the type of
Remote Unit. For details refer to section 7.2.2 Mechanical Specification. Install the unit
vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position
must be kept, as in the following illustrations:
7. A spacing of 40 mm (1.58 inch) around the unit is required.
8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one
for the air inlet and the other for the air outlet) have to be provided. Do not block these air
inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least
12 x 12 cm (144 cm2). Make sure, too, there is no thermal short circuit between the air inlet
and air outlet.
If any different or additional mounting material is used, ensure that the mounting remains as safe as the
mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for
the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any
way that might cause damage to the Remote Unit.
Specified torques have to be observed for certain mounting procedures according to the following table:
Type
Thread
Specified torques
Tallow-drop
screws
M4
3.3 Nm
Hex
Spacing
PG
PG
nuts
bolts
(plastic) (aluminium)
M8
M4
M8
PG 13.5 PG 29
27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm
table Fehler! Kein Text mit angegebener Formatvorlage im Dokument.-1 Specified torques
 Note:
To avoid damage when mounting the unit, always make sure that the M8 washers
(DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front
of the mounting drillings of the unit.
The mounting procedures for a stand-alone Remote Unit without optional accessories are described and
illustrated in the following sections. For further information regarding special mounting procedures
including mounting of accessory equipment, please see separate manual.
1.2. ELECTRICAL INSTALLATION
1.2.1. General
Read the health and safety warnings in chapter 1.3.
1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be
the result if the instructions contained in this manual are not followed.
2. Ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to
connect the ground-bonding cable.
3. Although the Remote Unit is internally protected against over-voltage, it is strongly recommended to
earth the antenna cables close to the antenna connectors of the Remote Unit for protection against
atmospheric discharge. In areas with strong lightning it is highly recommended to insert additional
lightning protection.
4. If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains
circuit must be provided within easy reach.
5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains
supply is disconnected.
6. Make sure that an appropriate circuit breaker and an over-current limiting device are connected
between mains and Remote Unit.
7. A connection of mains supply to a power socket requires the power socket to be nearby the Remote
Unit.
8. Incorrectly wired connections can destroy electrical and electronic components.
9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable
connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact
series).
10. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb),
with 13/16 inch opening to tighten the N-type antenna connectors. For example, use torque wrench
of item no. 244379 available from the Andrew e-catalog. Do NOT use your hands or any other tool
(e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the
Remote Unit.
11. Use a voltage limiting device for unstabilized electric networks that frequently generate spikes.
12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however,
it is recommended to install an additional medium (via local supply connection) and/or coarse
protection (external surge protection), depending on the individual application, in order to avoid
damage caused by overcurrent.
13. Observe the labels on the front panels before connecting or disconnecting any cables.
1.3. HEALTH AND SAFETY WARNINGS
1. Danger: Obey all general and regional installation and safety regulations relating to work on high
voltage installations, as well as regulations covering correct use of tools and personal protective
equipment.
2. Danger: Before opening the unit, disconnect mains power.
3. Danger: Laser radiation! Do not stare into the beam; do not view it directly or with optical
instruments.
4. Danger: Due to power dissipation, the remote unit may reach a very high temperature. Do not
operate this equipment on or close to flammable materials. Use caution when servicing the unit.
5. Warning: Read and obey all the warning labels attached to the unit. Make sure that all warning
labels are kept in a legible condition. Replace any missing or damaged labels.
6. Warning: It is the responsibility of the network provider to implement prevention measures to avoid
health hazards associated with radiation from the antenna(s) connected to the unit.
7. Warning: Make sure, access is restricted to qualified personnel.
8. Warning: Only license holders for the respective frequency range are allowed to operate this unit.
9. Warning: Make sure the repeater settings are correct for the intended use (refer to the manufacturer
product information) and regulatory requirements are met.
10. Warning: Use this equipment only for the purpose specified by the manufacturer. Do not carry out
any modifications or fit any spare parts, which are not sold or recommended by the manufacturer.
This could cause fires, electric shock, or other injuries.
11. Warning: For installations which have to comply with European EN50385 exposure compliance
requirements, the following Power Density limits/guidelines (mW/cm²) according to ICNIRP are
valid:
0.2 for frequencies from 10 MHz to 400 MHz
F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz
1 for frequencies from 2 GHz to 300 GHz
12. Warning: For installations, which have to comply with FCC RF exposure requirements, the antenna
selection and installation must be completed in a way to ensure compliance with those FCC
requirements. Depending on the RF frequency, rated output power, antenna gain, and the loss
between the repeater and antenna, the minimum distance D to be maintained between the antenna
location and human beings is calculated according to this formula:
D[ cm] 
P[ mW ]
4    PD[ mW / cm 2 ]
where

P (mW) is the radiated power at the antenna, i.e. the max. rated repeater output power in
addition to the antenna gain minus the loss between the repeater and the antenna.

PD (mW/cm²) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B) for general
population / uncontrolled exposures which is
o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz
o 1 for frequencies from 1500MHz to 100.000MHz
RF exposure compliance may need to be addressed at the time of licensing, as required by the
responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).
13. Caution: Installation of this equipment is in full responsibility of the installer, who has also the
responsibility, that cables and couplers are calculated into the maximum gain of the antennas, so that
this value, which is filed in the FCC Grant and can be requested from the FCC data base, is not
exceeded. The industrial boosters are shipped only as a naked booster without any installation
devices or antennas as it needs for professional installation.
14. Caution: Only suitably qualified personnel are allowed to work on this unit and only after becoming
familiar with all safety notices, installation, operation and maintenance procedures contained in this
manual.
15. Caution: Keep operating instructions within easy reach and make them available to all users.
16. Caution: Corresponding local particularities and regulations must be observed. For national
deviations, please refer to the respective documents included in the manual CD that is delivered with
the unit.
17. Caution: Although the remote unit is internally protected against overvoltage, it is strongly
recommended to ground (earth) the antenna cables close to the repeater’s antenna connectors for
protection against atmospheric discharge.
18. Caution: ESD precautions must be observed! Before commencing maintenance work, use the
available grounding (earthing) system to connect ESD protection measures.
19. Note: For a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
20. Note: This unit complies with European standard EN60950.
Equipment Symbols Used
Please observe the meanings of the following symbols used in our equipment and the compliance
warnings:
Symbol
---
Compliance
FCC
CE
Meaning
WARNING. This is NOT a CONSUMER device.
It is designed for installation by FCC
LICENSEES and QUALIFIED INSTALLERS.
You MUST have an FCC LICENSE or express
consent of an FCC Licensee to operate this
device. Unauthorized use may result in
significant forfeiture penalties, including
penalties in excess of $100,000 for each
continuing violation.
Alert sign to R&TTE
To be sold exclusively to mobile operators or
authorized installers – no harmonised frequency
bands, operation requires license
Intended use: EU and EFTA countries
Indicates conformity with the R&TTE directive
1999/5/EC certified by the notified body no.
0700.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : FRFUTTER
Create Date                     : 2013:08:28 17:38:17+02:00
Modify Date                     : 2013:08:28 17:38:17+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Microsoft Word - Installation Instruction.doc
Creator                         : FRFUTTER
Producer                        : Acrobat Distiller 9.4.6 (Windows)
Document ID                     : uuid:26a8b7a5-ac16-4e76-9754-629d93be61b1
Instance ID                     : uuid:3657d068-43f1-4161-a2cd-68730a9ce5d5
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XS5-M7P17HP

Navigation menu