Andrew Wireless System UEUH781719P ION-U Extension Unit for cellular systems User Manual User s Manual for ION U
Andrew Wireless System ION-U Extension Unit for cellular systems User s Manual for ION U
Contents
- 1. user manual
- 2. Installation Instruction
user manual
® ION -U EU H 7P/80-85P/17P/19P Extension Unit User's Manual M0200A9C DISCLAIMER: This document has been developed by CommScope, and is intended for the use of its customers and customer support personnel. The information in this document is subject to change without notice. While every effort has been made to eliminate errors, CommScope disclaims liability for any difficulties arising from the interpretation of the information contained herein. The information contained herein does not claim to cover all details or variations in equipment, nor to provide for every possible incident to be met in connection with installation, operation, or maintenance. This document describes the performance of the product under the defined operational conditions and does not cover the performance under adverse or disturbed conditions. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, contact CommScope. CommScope reserves the right to change all hardware and software characteristics without notice. COPYRIGHT: © Copyright 2015 CommScope Inc. All Rights Reserved. This document is protected by copyright. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical photocopying, recording, or otherwise without the prior written permission of CommScope. TRADEMARKS All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. Andrew Wireless Systems GmbH, 08-July-2015 Page 2 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Table of Contents TABLE OF CONTENTS 1. GENERAL 1.1. USED ABBREVIATIONS 1.2. HEALTH AND SAFETY 1.3. PROPERTY DAMAGE WARNINGS 1.4. COMPLIANCE 1.5. ABOUT COMMSCOPE 11 1.6. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 12 2. INTRODUCTION 14 2.1. PURPOSE 14 2.2. ION-U HIGH POWER REMOTE AND EXTENSION UNITS 14 3. FUNCTIONAL DESCRIPTION 15 4. COMMISSIONING 16 4.1. GENERAL 16 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. HIGH POWER EU MECHANICAL INSTALLATION Health and Safety for mechanical installation Property Damage Warnings for mechanical installation Mounting distance between RU and EU Wall mounting procedure Pole mounting procedure with screw bands Pole mounting procedure with brackets 16 16 16 18 19 20 21 4.3. ELECTRICAL INSTALLATION 4.3.1. Health and Safety for electrical installation 4.3.2. Property Damage Warnings for electrical installation 4.3.3. Connections 4.3.4. Grounding (Earthing) 4.3.5. Connection of the antenna cable 4.3.5.1. Cleaning procedure for RF cable connectors 4.3.5.2. Antenna cable connector assembly 4.3.6. Mains power connection 4.3.6.1. Mains power connection AC 4.3.6.2. Mains power connection DC 4.3.7. Extension Unit port connection 4.3.8. Coupling Probe 23 23 23 24 27 28 29 32 33 33 35 37 38 4.4. 39 COMMISSIONING FLOW-CHART M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 3 Table of Contents 5. ALARMS 41 5.1. BITE AND ALARMS 41 5.2. TROUBLESHOOTING 41 5.3. STATUS LED ALARMS 41 6. MAINTENANCE 42 6.1. GENERAL 42 6.2. REPLACING THE FAN UNIT 43 6.3. CLEANING THE HEAT SINK 44 7. APPENDIX 45 7.1. ILLUSTRATIONS 45 7.2. SPECIFICATIONS 46 7.3. SPARE PARTS 46 7.4. LIST OF CHANGES 46 8. INDEX Page 4 47 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Figures and Tables FIGURES AND TABLES figure 3-1 ION-U High Power EU block diagram....................................................... 15 figure 4-1 Maximum distance between RU and EU .................................................. 18 figure 4-2 Wall mounting - pitches ............................................................................ 19 figure 4-3 Pole mounting - pitches ............................................................................ 20 figure 4-4 Pole mounting - screw bands ................................................................... 20 figure 4-5 Pole mounting - fasten EU........................................................................ 20 figure 4-6 Pole mounting – max. diameter ................................................................ 21 figure 4-7 Pole mounting – with brackets .................................................................. 21 figure 4-8 Pole mounting - pitches ............................................................................ 22 figure 4-9 Pole mounting - brackets .......................................................................... 22 figure 4-10 Pole mounting - fasten EU...................................................................... 22 figure 4-11 ION-U EU H 7P/80-85P/17P/19P AC version connector flange ............. 24 figure 4-12 ION-U EU H 7P/80-85P/17P/19P DC version connector flange ............. 26 figure 4-13 Grounding bolts ...................................................................................... 27 figure 4-14 Grounding bolt, schematic view .............................................................. 27 figure 4-15 Mains power connector .......................................................................... 34 figure 4-16 Mains power cable - AC ......................................................................... 34 figure 4-17 EU (Extension Unit) connector ............................................................... 37 figure 4-18 EU connector and cable bridge .............................................................. 37 figure 4-19 Mounting the EU cable bridge ................................................................ 38 figure 7-1 ION-U EU H 7P/80-85P/17P/19P required space..................................... 45 table 4-1 Specified torques ....................................................................................... 17 table 4-2 ION-U EU H connector flange ................................................................... 25 table 4-3 AC power cable pinning ............................................................................. 34 table 4-4 EU connector pinning ................................................................................ 37 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 5 1. General 1. General 1.1. Used Abbreviations AC/DC AIMOS ALC Alternating current / Direct Current Andrew Integrated Management and Operating System Automatic Level Control BITE BTS Built-In Test Equipment Base Transceiver Station CDMA CE CFR CPD Code Division Multiple Access "Conformité Européenne" ("European Conformity") Code of Federal Regulations Channel Power Detection DL DoC Downlink Declaration of Conformity EP ESD EU Extension Port Electrostatic Discharge Extension Unit GSM GND GUI Global System for Communication Ground (Earth) Graphical User Interface ICP3 ID No ION Intercept Point 3 order Identification Number Intelligent Optical Network LED LMT LTE Light Emitting Diode Local Maintenance Terminal Long Term Evolution MIMO MS MU Multiple Input Multiple Output Mobile Station Main Unit NF Noise Figure OMC PIM Pin Pout PSU Operations and Maintenance Center Optical Transceiver = SRMU (Subrack Master Unit) Passive Intermodulation Input power Output power Power Supply Unit Rev RF RU RX Revision Radio Frequency Remote Unit Receiver SISO SNMP Single Input Single Output Simple Network Management Protocol TX Transmitter UL UMTS UPS Uplink Universal Mobile Telecommunication System Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA WDM Wideband Code Division Multiple Access Wavelength Division Multiplex XML Extensible Markup Language OTRx Page 6 rd Mobile M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 1. General 1.2. Health and Safety 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Before opening the unit, disconnect mains power. 3. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the unit’s inner conductor of the antenna port(s). Disconnect mains before connecting or replacing antenna cables. 4. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the antenna(s) connected to the unit. Implement prevention measures to avoid the possibility of close proximity to the antenna(s) while in operation. 1.3. Property Damage Warnings 1. Attention: Due to power dissipation, the Extension Unit may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Use caution when servicing the unit. 2. Attention: Only authorized and trained personnel are allowed to open the unit and get access to the inside. 3. Notice: Although the Extension Unit is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the repeater’s antenna connectors for protection against atmospheric discharge. 4. Notice: ESD precautions must be observed. Before commencing maintenance work, use the available grounding (earthing) system to connect ESD protection measures. 5. Notice: Only suitably qualified personnel are allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 6. Notice: Keep operating instructions within easy reach and make them available to all users. 7. Notice: Read and obey all the warning labels attached to the unit. Make sure that all warning labels are kept in a legible condition. Replace any missing or damaged labels. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 7 1. General 8. Notice: Only license holders for the respective frequency range are allowed to operate this unit. 9. Notice: Make sure the repeater settings are correct for the intended use (refer to the manufacturer product information) and regulatory requirements are met. Do not carry out any modifications or fit any spare parts, which are not sold or recommended by the manufacturer. 1.4. Compliance 1. Notice: For installations which have to comply with European EN50385 exposure compliance requirements, the following Power Density limits/guidelines (mW/cm²) according to ICNIRP are valid: 0.2 for frequencies from 10 MHz to 400 MHz F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz 1 for frequencies from 2 GHz to 300 GHz 2. Notice: For installations, which have to comply with FCC RF exposure requirements, the antenna selection and installation must be completed in a way to ensure compliance with those FCC requirements. Depending on the RF frequency, rated output power, antenna gain, and the loss between the repeater and antenna, the minimum distance D to be maintained between the antenna location and human beings is calculated according to this formula: D[ cm ] = P[ mW ] 4 ∗ π ∗ PD[ mW / cm 2 ] where • P (mW) is the radiated power at the antenna, i.e. the max. rated repeater output power in addition to the antenna gain minus the loss between the repeater and the antenna. • PD (mW/cm²) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B) for general population / uncontrolled exposures which is o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz o 1 for frequencies from 1500MHz to 100,000MHz RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). 3. Notice: Installation of this equipment is in full responsibility of the installer, who has also the responsibility, that cables and couplers are calculated into the maximum gain of the antennas, so that this value, which is filed in the FCC Grant and can be requested from the FCC data base, is not exceeded. The industrial boosters are shipped only as a naked booster without any installation devices or antennas as it needs for professional installation. Page 8 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 1. General 4. Notice: For installations which have to comply with FCC/Industry Canada requirements: English: This device complies with FCC Part 15 and Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with Health Canada’s Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canada’s requirement. Information can be obtained at http: //www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. French: Cet appareil est conforme à FCC Partie15 d’Industrie Canada RSS standard exempts de licence (s). Son utilisation est soumise à Les deux conditions suivantes: (1) cet appareil ne peut pas provoquer d’interférences et (2) cet appareil doit accepter Toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. Cet appareil est conforme avec Santé Canada Code de sécurité 6. Le programme d’installation de cet appareil doit s’assurer que les rayonnements RF n’est pas émis audelà de I’exigence de Santé Canada. Les informations peuvent être obtenues: http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-fra.php Les changements ou modifications non expressément approuvés par la partie responsable de la conformité pourraient annuler l'autorité de l'utilisateur à utiliser cet équipement. 5. Notice: Corresponding local particularities and regulations must be observed. For national deviations, please refer to the respective documents included in the manual CD that is delivered with the unit. 6. Notice: The unit complies with Overvoltage Category II. It also complies with the surge requirement according to EN 61000-4-5 (fine protection); however, installation of an additional medium (via local supply connection) and/or coarse protection (external surge protection) is recommended depending on the individual application in order to avoid damage caused by overcurrent. For Canada and US, components used to reduce the Overvoltage Category shall comply with the requirements of IEC 61643-series. As an alternative, components used to reduce the Overvoltage Category may comply with ANSI/IEEE C62.11, CSA Certification Notice No. 516, CSA C22.2 No. 1, or UL 1449. Suitability of the component for the application shall be determined for the intended installation. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 9 1. General 7. Note: For a Class A digital device or peripheral: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 8. Note: This unit complies with European standard EN60950. Equipment Symbols Used / Compliance Please observe the meanings of the following symbols used in our equipment and the compliance warnings: Symbol --- Compliance FCC CE Meaning / Warning Unit is for FCC Part 20 purposes - COMMERCIAL MOBILE SERVICES – only. WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Alert sign to R&TTE To be sold exclusively to mobile operators or authorized installers – no harmonized frequency bands, operation requires license. Intended use: EU and EFTA countries Indicates conformity with the R&TTE directive 1999/5/EC certified by the notified body no. 0700. Note: The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is reradiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. Page 10 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 1. General 1.5. About CommScope CommScope is the foremost supplier of one-stop, end-to-end radio frequency (RF) solutions. Part of the CommScope portfolio are complete solutions for wireless infrastructure from top-of-the-tower base station antennas to cable systems and cabinets, RF site solutions, signal distribution, and network optimization. For patents see www.cs-pat.com. CommScope has global engineering and manufacturing facilities. In addition, it maintains field engineering offices throughout the world. Andrew Wireless Systems GmbH based in Buchdorf/ Germany, which is part of CommScope, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage and capacity solution for wireless networks in both indoor installations and outdoor environments, e.g. tunnels, subways, in-trains, airport buildings, stadiums, skyscrapers, shopping malls, hotels and conference rooms. Andrew Wireless Systems GmbH operates a quality management system in compliance with the requirements of ISO 9001 and TL 9000. All equipment is manufactured using highly reliable material. To maintain highest quality of the products, comprehensive quality monitoring is conducted at all fabrication stages. Finished products leave the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal operation. This product meets the requirements of the R&TTE directive and the Declaration of Conformity (DoC) itself. A current version of the CE DoC is included in this manual CD delivered *. Any updated version of the DoC is available upon request from the local sales offices or directly from CommScope via the local Customer Support at one of the addresses listed in the following chapter. According to the DoC, our "CE"-marked equipment can be used in all member states of the European Union. F Note: Exceptions of and national deviations from this intended use may be possible. To observe corresponding local particularities and regulations, please refer to the respective documents (also in national language) which are included in the manual CD delivered. * In case the Declaration of Conformity (DoC) for the product was not included in the manual CD delivered, it is available upon request from the local sales offices or directly from CommScope at one of the addresses listed in the following chapter. To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions. For technical assistance and support, please also contact the local office or CommScope directly at one of the addresses listed in the following chapter. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 11 1. General 1.6. International Contact Addresses for Customer Support Canada United States CommScope Canada Andrew LLC, A CommScope Company Mail 505 Consumers Road, Suite 803 Toronto M2J 4V8, Canada Mail 620 North Greenfield Parkway Garner, NC 27529, U.S.A. Phone +1-905-878-3457 (Office) +1-416-721-5058 (Cell) Phone +1-888-297-6433 Fax +1-905-878-3297 A Fax E-mail wisupport@commscope.com Caribbean & South American Region CommScope Cabos do Brasil Ltda. Mail CALA Tech Support for Distributed Coverage & Capacity Solutions (DCCS) products: Rua Guaporanga, 49 Praça Seca – Rio de Janeiro – RJ ZIP: 21320-180, Brazil +1-919-329-8950 M E-mail wisupport@commscope.com Caribbean & Central American Region CommScope Mexico S.A. de C.V. CALA Tech Support for Distributed Coverage & Capacity Solutions (DCCS) products: S Mail Av. Insurgentes Sur 688, Piso 6 Col. Del Valle, CP: 03100 Mexico City, Mexico Phone +1-815-546-7154 (Cell) +55-15-9104-7722 (Office) Phone +52-55-1346-1900 (Office) Fax + 55-15-2102-4001 Fax +52-55-1346-1901 E-mail wisupport@commscope.com E-mail wisupport@commscope.com China, India and Rest of Asia Andrew International Corporation Mail Room 915, 9/F Chevalier Commercial Centre 8 Wang Hoi Rd Kowloon Bay, Hong Kong Phone +852-3106-6100 Fax +852-2751-7800 E-mail wisupport.China@commscope.com Australia & New Zealand Andrew Corporation (Australia) Pty Ltd. P Mail C Phone Unit 1 153 Barry Road Campbellfield VIC 3061, Australia +613-9300-7969 Fax +613-9357-9110 E-mail wisupport.Australia@commscope.com Middle East & North Africa CommScope Solutions International Inc. (Branch) South Africa Andrew Wireless Solutions Africa (PTY) LTD Africa Mail Middle East Mail PO Box 48 78 22 Unit 3206, Floor 32, Jumeirah Business Center 5, Jumeirah Lakes Towers, Dubai, United Arab Emirates Phone +971 4 390 09 80 Phone + 27 11-719-6000 Fax +971 4 390 86 23 Fax + 27 11-444-5393 E-mail wisupport@commscope.com E-mail wisupport@commscope.com Page 12 11 Commerce Crescent West Eastgate, Sandton PO Box 786117 Sandton 2146 South Africa M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 1. General United Kingdom Scandinavia Andrew Wireless Systems UK Ltd Andrew Norway (AMNW) Mail Unit 15, Ilex Building Mulberry Business Park Fishponds Road Wokingham Berkshire RG41 2GY, England Mail P.O. Box 3066 Osloveien 10 Hoenefoss 3501 Norway Phone +44-1189-366-792 Phone + 47 32-12-3530 Fax +44-1189-366-773 Fax + 47 32-12-3531 E-mail wisupport.uk@commscope.com E-mail wisupport@commscope.com Germany France Andrew Wireless Systems GmbH CommScope France Mail Industriering 10 86675 Buchdorf Germany Phone +49-9099-69-0 Mail Weglgasse 10 2320 Wien-Schwechat Austria Mail Tiergartenweg 1 CH-4710 Balsthal Switzerland Phone +43-1706-39-99-10 Phone +41-62-386-1260 Fax +43-1706-39-99-9 Fax +41-62-386-1261 E-mail wisupport.austria@commscope.com E-mail wisupport.ch@commscope.com Mail E Phone Immeuble Le Lavoisier 4, Place des Vosges 92052 Courbevoie, France +33-1 82 97 04 00 Fax +49-9099-69-930 Fax +33-1 47 89 45 25 E-mail wisupport@commscope.com wisupport@commscope.com O E-mail Austria Switzerland Andrew Wireless Systems (Austria) GmbH E CommScope Wireless Systems AG Italy Iberia Region - Spain & Portugal CommScope Italy S.r.l., Faenza, Italy Andrew España S.A. A CommScope Company Mail Via Mengolina, 20 48018 Faenza (RA) Italy Mail Avda. de Europa, 4 - 2ª pta. Parque Empresarial de la Moraleja Alcobendas, Madrid 28108, Spain Phone +39-0546-697111 Phone +34-91-745-20 40 Fax +39-0546-682768 Fax +34-91-661-87 02 E-mail wisupport.italia@commscope.com E-mail wisupport.iberia@commscope.com Czech Republic CommScope Solutions Czech Republic C-Com, spol. s r.o Mail U Moruší 888 53006 Pardubice, Czech Republic Phone +49 871 9659171 (Office) +49 171 4001166 (Mobile) Fax +49 871 9659172 E-mail wisupport@commscope.com M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 13 2. Introduction 2. Introduction 2.1. Purpose Mobile telephone and public safety systems transmit signals in two directions between base transceiver station (BTS) and mobile stations (MS) within the signal coverage area to carry voice and data traffic. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distributed antenna system (DAS). Office buildings, sports arenas, college campuses, industrial parks, and other areas of high demand require the specialized capacity boost that an optical DAS can provide to meet increasing customer demands for voice and data. An optical DAS contains optical Master Units and a sufficient number of Remote Units to provide the necessary coverage. The number of the Remote Units depends on the coverage requirements of the DAS. Extension Units can be connected to Remote Units to provide coverage for further bands. The Remote Units are connected to the Master Unit with optical links. The Master Unit is the connection to the Base Transceiver Stations. The configuration of a Master Unit depends on the number of the Remote Units and the frequency range. 2.2. ION-U High Power Remote and Extension Units The ION-U is an optical fiber based DAS system that efficiently takes the outputs of multiple Base Transceiver Stations (BTS) sectors and converts those RF signals to optical to send them over fiber optic cables to Remote Units to provide coverage in indoor and outdoor locations. The system supports both low power and high power Remote Units and SISO and MIMO operation. The ION-U EU H 7P/80-85P/17P/19P is a multi-band, multi-operator Extension Unit used in conjunction with a Remote Unit in the ION optical distribution system. This system transports up to five frequency bands simultaneously (700 MHz, 800/850 MHz, and 1900 MHz), providing a cost-effective solution for distributing capacity from one or more base stations. It has been specifically tested and optimized for GMSK, EDGE, CDMA, UMTS, HSPA+, LTE, and OFDM modulations. Furthermore it is provisioned for future modulation scheme evolutions. These Remote and Extension Units feature independent downlink and uplink gain adjustments and an integrated channel power detector for in-band spectrum and PIM analysis and end-to-end auto leveling. Page 14 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 3. Functional Description 3. Functional Description Frequency Conversion Unit Diplexer Unit Power Amplifier Duplexer Unit 700 MHz UL Amp f2 f1 800-850 MHz From / To Mobile Station From / To 4.3-10 Connector 1900 MHz Remote Unit f2 UL Amp f1 2100 MHz f2 f1 f2 f1 figure 3-1 ION-U High Power EU block diagram In the Downlink (DL) path, the Extension Unit provides: • Automatic Gain Control (AGC) of each converted signal to compensate for optical losses • RF amplification of the converted RF signal for transmission while maintaining an excellent signal-to-noise ratio • RF filtering to reject spurious emissions In the Uplink (UL) path, the Extension Unit provides: • RF amplification to boost the signals received by the antennas to maintain an excellent signal-to-noise ratio • RF filtering to reject spurious emissions • Automatic Level Control (ALC) to adjust the RF signal level to meet blocking requirements M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 15 4. Commissioning 4. Commissioning 4.1. General Read and observe chapter 1.2 Health and Safety as well as the description carefully to avoid mistakes and proceed step by step as described. • Do not operate the Extension Unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load. • Only qualified personnel should carry out the electrical, mechanical, commissioning, and maintenance activities that require the unit to be powered on when open. • When opening the Extension Unit do not damage the warranty labels on the internal devices. The warranty is void if the seals are broken. 4.2. High Power EU Mechanical Installation 4.2.1. Health and Safety for mechanical installation Read and observe chapter 1.2 Health and Safety. 1. Caution: Risk of injury by the considerable weight of the unit falling. Ensure there is adequate manpower to handle the weight of the system. 2. Caution: Risk of serious personal injury by equipment falling due to improper installation. The installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components. The screws and dowels (wall anchors) used should also be appropriate for the structure of the supporting wall. 4.2.2. Property Damage Warnings for mechanical installation 1. Attention: Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. Attention: Due to power dissipation, the Extension Unit may reach a very high temperature. Ensure sufficient airflow for ventilation. 3. Notice: Exceeding the specified load limits may cause the loss of warranty. 4. Notice: When connecting and mounting the cables (RF, expansion, mains, ...) ensure that no water can penetrate into the unit through these cables. 5. Notice: Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded. See chapter 7.1 for more details. Page 16 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 6. Notice: If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. The specifications for stationary use of the Extension Unit must not be exceeded. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Extension Unit. 7. Notice: Observe all additional rules or restrictions regarding mounting that apply to specific Extension Unit types. For details refer to the mechanical specifications in the data sheet for the unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be maintained, as shown in the following illustrations: 8. Notice: A spacing of 40 mm (1.58 inch) around the unit is required. 9. Notice: To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) must be provided. Do not block these air inlets and outlets when mounting the Extension Unit. The size of each opening must equal at least 18 x 18 cm (> 300 cm2). Ensure that there is no thermal short circuit between the air inlet and air outlet. Make sure free airflow is not deflected or otherwise obstructed. Specified torques must be observed for certain mounting procedures according to the following table: Type Thread Specified torques Tallow-drop screws Hex nuts M4 3.3 N-m M8 27 N-m Screw band lock 6 N-m Spacing bolts M4 2.3 N-m PG (plastic) M8 PG 13.5 27 N-m 3.75 N-m PG (alum.) PG 29 10 N-m table 4-1 Specified torques M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 17 4. Commissioning 4.2.3. Mounting distance between RU and EU The Extension Unit has to be connected to the Remote Unit via cable bridge. The length of the cable bridge determines the maximum mounting distance between the Remote Unit and the Extension Unit. Length 420 mm 1200 mm 2000 mm Distance 45 mm / 1.77” 825 mm 32.48” 1625 mm / 63.97 max. Distance Cable bridge from/to RU R1 min figure 4-1 Maximum distance between RU and EU Page 18 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 4.2.4. Wall mounting procedure Notice: It is the responsibility of the installer to verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components and to ensure that the EU is safely and securely mounted. 1. Mark the position of the drilling holes (for pitches refer to figure 4-2 Wall mounting). Drill four holes at the marked positions and insert dowels*. 2. Mount the brackets (A) to the wall using the M8x80 screws (B), split lock washers (C), and washers (D). figure 4-2 Wall mounting - pitches 3. Hang the Extension Unit into the upper bracket, insert it to the lower bracket, and fasten it to the lower bracket with the M8x25 screws (E), split lock washers (F), and washers (G). * The dowels are not included with the delivery because the suitable type depends on the on-site conditions (material of wall). M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 19 4. Commissioning 4.2.5. Pole mounting procedure with screw bands Standard mounting hardware cannot be used to mount the Extension Unit to a pole, a column, or other similar structures. Additional hardware must be used for this type of installation. The pole-mounting kit includes • two mounting brackets with screw bands, (worm gear) clamps to mount the brackets to the pole • and two M8x25 screws, flat washers, and split lock washers per bracket to attach the Extension Unit to the bracket. 775 min. 788 max. figure 4-3 Pole mounting - pitches figure 4-4 Pole mounting - screw bands figure 4-5 Pole mounting fasten EU 1. Use two screw bands (B) for the upper and one for the lower bracket to fasten the two brackets (A) to the pole. 2. Place the bands around the pole or post and feed the loose end into the lock and tighten the slotted screw securely. When the screw is turned clockwise, it acts as a worm drive pulling the threads of the band causing the band to tighten around the pole. F Note: When fastening the brackets make sure that they are installed congruently and not at an angle to each other. To determine the distance between the clamps refer to figure 4-3 Pole mounting - pitches. Page 20 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 3. Hang the Extension Unit into the upper bracket, insert it into the lower bracket, and fasten it to the lower bracket with the M8x25 screws (C), split lock washers (D) and washers (E), see chapter 4.2.4. The maximum diameter of the pole or column must not exceed 120 mm (4.7 inch). ax. figure 4-6 Pole mounting – max. diameter 4.2.6. Pole mounting procedure with brackets The pole-mounting kit with brackets includes • two mounting brackets (A), two counter brackets (B), four threaded bolts (C), flat (F) and split lock (G) washers, hexagon (E) and locking (D) nuts to mount the brackets to the pole • and two M8x25 screws (H), flat (F) and split lock (G) washers to attach the Extension Unit to the bracket. figure 4-7 Pole mounting – with brackets M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 21 4. Commissioning figure 4-8 Pole mounting - pitches figure 4-9 Pole mounting - brackets figure 4-10 Pole mounting - fasten EU 1. Apply this procedure to both mounting brackets on both sides: Screw a hexagon nut (E) to the threaded bolt and place a flat washer (F)) on it. Insert this side of the bolt into the mounting bracket (A). Then, fasten the mounting bracket with a flat washer (F), split lock washer (G), and the locking nut (D). See figure 4-7 Pole mounting – with brackets. 2. Place the pre-mounted brackets with threaded bolts to the pole or post, slide the counter bracket (B) on the threaded bolts and fasten the kit with a flat washer (F), split lock washer (G), and the locking nut (D). F Note: When fastening the brackets make sure that they are installed congruently and not at an angle to each other. To determine the distance between the clamps refer to figure 4-8 Pole mounting - pitches. 3. Hang the Extension Unit into the upper bracket, insert it into the lower bracket (see chapter 4.2.4), and fasten it to the lower bracket with the M8x25 screws (H), split lock washers (G), and flat washers (F). The diameter of the pole or column must be in the range from 65 to 120 mm (2.6 to 4.7 inch). Page 22 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 4.3. Electrical Installation 4.3.1. Health and Safety for electrical installation Read and observe the notices in chapter 1.2 Health and Safety. 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 4.3.2. Property Damage Warnings for electrical installation 1. Attention: It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is provided on the cabinet to connect the groundbonding cable. 2. Attention: If the mains connector of the Extension Unit is not easily accessible, a disconnect device in the mains power circuit must be provided within easy reach. 3. Attention: A connection of the mains supply to a power socket requires the power socket to be nearby the Extension Unit. 4. Attention: Before connecting or disconnecting the mains connector at the Extension Unit, ensure that mains power supply is disconnected. 5. Attention: Make sure that an appropriate circuit breaker acting as a disconnect device (as required by IEC/EN60950-1) and an overcurrent limiting device are connected between mains power and the Extension Unit. 6. Attention: Incorrectly wired connections can destroy electrical and electronic components. 7. Notice: Although the Extension Unit is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the antenna connectors of the Extension Unit for protection against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install additional lightning protection. 8. Notice: To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 9. Notice: Use an appropriate torque wrench for the coupling torques: for N-type connectors (2 N-m / 20 in lb) with 13/16 in opening, e. g. item no. 244379 available from the CommScope e-catalog for 7/16 DIN-type (25 N-m / 19 ft lb) with 1 ¼ in opening, e. g. item no. 244377 available from the CommScope e-catalog for 4.3-10 type connectors (5 N-m, 44 in lb) with 22 mm (7/8) in opening Do NOT use your hands or any other tool (e.g. a pair of pliers). This might cause damage to the connector and lead to a malfunction of the Extension Unit. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 23 4. Commissioning 10. Notice: For unstabilized electric networks, which frequently generate spikes, the use of a voltage limiting device is advised. 11. Notice: Observe the labels on the front panels before connecting or disconnecting any cables. 12. Notice: Unused connectors must be closed with their protective covers to ensure water tightness. 4.3.3. Connections The ION-U EU ports and connectors shown below are located at the base of the EU. figure 4-11 ION-U EU H 7P/80-85P/17P/19P AC version connector flange Page 24 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning Port/Conn EXPANSION ANT STATUS PROBE Grounding Bolts MAINS ION-U High Power EU Connectors/Indicators Purpose This connector is used to interconnect to the Remote Unit to provide additional bands of coverage. This connector is used for transmitting and receiving signals to and from an antenna, antenna splitter, or cross-band coupler. This LED provides a visual warning of an alarm condition. The color of the LED indicates the severity of the alarm. This connector is used as measurement probe to antenna port. Ground (earth) bolts for connecting the mandatory ground cable to the EU. This connector provides the power to EU models that use standard AC (100 to 240 Vac) power. Type Radiall Opus M424400003 4.3-10 type female LED QMA M6 bolts, hex nut, & washers Coninvers M17 –Series P20, 4-Pin table 4-2 ION-U EU H connector flange M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 25 4. Commissioning figure 4-12 ION-U EU H 7P/80-85P/17P/19P DC version connector flange Port/Conn ION-U High Power EU Connectors/Indicators Purpose All, except MAINS The connectors and indicators for the AC and the DC version are identical except for the MAINS connector. MAINS This connector provides the power to EU models that use standard DC (-60 to -48 Vdc) power. Page 26 Type M6 bolts, hex nut, & washers M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 4.3.4. Grounding (Earthing) The EU must be grounded (earthed). When double grounding lugs are used they must support M6 studs with a stud hole spacing of 15.88 mm (5/8”). 1. Connect an earth-bonding cable to one or both of the grounding bolt connections provided on the connector flange of the Extension Unit. Do not use the grounding connection to connect external devices. figure 4-13 Grounding bolts figure 4-14 Grounding bolt, schematic view 2. After loosening the hex nut(s), connect the earth-bonding cable between the two washers as illustrated in the figures above. 3. Then, fasten all parts again by tightening the hex nut(s). 4. Connect the other end of the ground wire to a suitable permanent ground. Note: Ground of a second unit (for example RU + EU) has to be connected to the same equipotential bonding terminal as the Remote Unit. Use bonding cables of the same length, as short as possible, and with a large wire cross section. Follow local electrical code practices. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 27 4. Commissioning 4.3.5. Connection of the antenna cable The Extension Unit has 4.3-10 type antenna connectors labelled “ANT”. When attaching the antenna cable connector, it is recommended to refer to the corresponding documentation of the connector manufacturer. The bending radius of the antenna cable must remain within the given specifications. The selection of cable and antenna is an important consideration. On the one hand, a cable with higher loss is less expensive but, on the other hand, it impairs performance. Notice: Use an appropriate torque wrench for the coupling torques: for N-type connectors (2 N-m / 20 in lb) with 13/16 in opening, e. g. item no. 244379 available from the CommScope e-catalog for 7/16 DIN-type (25 N-m / 19 ft lb) with 1 ¼ in opening, e. g. item no. 244377 available from the CommScope e-catalog - for 4.3-10 type connectors (5 N-m, 44 in lb) with 22 mm (7/8) in opening Do NOT use your hands or any other tool (e.g. a pair of pliers). This might cause damage to the connector and lead to a malfunction of the Extension Unit. Attention: To minimize passive inter-modulation (PIM) distortion, attention has to be paid to the physical condition of the connector junctions: • Do not use connectors that show signs of corrosion on the metal surface. • Prevent the ingress of water or dirt into the connector. • Use protective caps for the connectors when not mounted. • Before mounting clean the connectors with dry compressed air. • Before mounting clean the mating surfaces of the connector with a lint-free alcohol-drenched cloth on a wooden or non-metallic item. • Attach and torque the connectors properly. • Avoid metallic abrasion when mounting the connectors by only screwing the connecting nut, but not turning the whole connector. • Use a torque wrench to fasten the connector, see above. • Clean the protective caps before mounting for antenna cable replacement. Page 28 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 4.3.5.1. Cleaning procedure for RF cable connectors 1. What is needed for the cleaning? a. Isopropyl alcohol b. Compressed air c. Lint-free wipe d. Cotton buds 2. Remove protective cap from the RF connector. 3. Remove metal chips and small particles from the mating and inner surfaces of the connector using compressed air. 4. Clean the connector winding with lintfree wipe drenched with isopropyl alcohol. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 29 4. Commissioning 5. Clean the lip of the inner ring with lint-free wipe drenched with isopropyl alcohol. 6. Clean the inside surface of the inner ring with lint-free wipe drenched with isopropyl alcohol. 7. Clean the inside of the center conductor spring tines with a cotton bud drenched with isopropyl alcohol. 8. Clean in the similar way the connector of the connected cable. Remove protective caps from the unit connector first. Page 30 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 9. Remove metal chips and small particles from the mating and inner surfaces of the connector using compressed air. 10. Continue with the winding area using lint-free wipe drenched with isopropyl alcohol. 11. Continue with the inside mating surface of the inner ring. 12. Clean the outside surface of the center pin. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 31 4. Commissioning 4.3.5.2. Antenna cable connector assembly 1. What is needed for the connector assembly? a. Torque wrench. b. (Adjustable) counter wrench 2. Join the connectors and turn the coupling nut until the thread grips. 3. Push in the connector until it clicks. 4. Fasten the coupling nut hand-tight. Do not turn the connector but the coupling nut only. Page 32 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 5. Retain the cable connector with the counter wrench and fasten the coupling nut with the Torque wrench torque wrench until the torque is applied (torque wrench clicks). Counter wrench For angled antenna connectors use your hand to retain the cable connector and fasten the coupling nut with the torque wrench. Make sure only the coupling nut is turned, not the cable connector. 4.3.6. Mains power connection Before connecting electrical power to the unit, the system must be grounded as described in the previous chapter. Mains power must be connected at the mains connector of the unit. 4.3.6.1. Mains power connection AC 1. Take the Mains power cable that was delivered with the EU. 2. Locate or install a suitable power junction box or receptacle near the EU and route the power cable from the power source to the EU. Do not connect the cable to the EU’s Mains connector at this time. The power source must be interruptible. 3. The Mains cable must be properly secured observing local regulations and electrical codes. Be sure to allow enough slack in the cable at the EU to plug or unplug the cable into the Mains connector of the EU. 4. Wire the power cable to the junction box or receptacle. Refer to the color code and pin numbers shown in figure 4-16 (AC cable), and table 4-3. 5. With the cable’s Mains plug disconnected from the EU, turn the circuit breaker on, unscrew the plug’s protective cover, and carefully test the plug with a voltmeter to ensure that the voltage and polarity are correct. 6. Once the testing has been completed, turn off the circuit breaker. 7. Unscrew the protective cover from the Mains connector of the EU (figure 4-15). 8. Insert the plug into the Mains connector and tighten the clamping ring until it is hand tight. Do not over-tighten the clamping ring. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 33 4. Commissioning Pin PE Pin1 Pin3 Pin2 figure 4-15 Mains power connector figure 4-16 Mains power cable - AC The Mains cable is part of the delivery. It’s available in two wiring configurations: Protective Cap Pin PE Wiring 1 Name Color Phase Black Neutral White n.c. n.c Ground Green Pin PE Wiring 2 Name Color Phase Brown Neutral Blue n.c. n.c Ground Green/Yellow table 4-3 AC power cable pinning For the AC power supply connection, a minimum cross section of 1.5 mm2 is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. F Note: Do not connect or disconnect the power cord at the mains connector while power is on. Turn off mains* power before connecting the power cord at the Extension Unit, then, engage mains again. Mains power must be interrupted with an external mains breaker. For the mains breaker, observe the following recommendation: 120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 13 - 16 Amps for 240-Volt service. Page 34 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 4.3.6.2. Mains power connection DC Caution: Danger of electrical hazard by high current. Disconnect mains power before opening the DC connector housing. Note: The Mains cable must be properly secured observing local regulations and electrical codes. Be sure to allow enough slack in the cable at the EU to mount or dismount the cable into the DC Mains connector of the EU. Unscrew the two M3 x 12 captive screws and take off the cover from the DC Mains connector housing. At the EU housing the cover is inserted into a recess, so first lift the cover at the front and carefully pull it out from the recess. Then remove the rubber plug. Rubber plug Double lug DC cable connectors need to be M6 with a stud hold spacing of 15.88 mm (5/8”). M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 35 4. Commissioning First, install a conduit fitting (not contained in scope of delivery) to the 34.52 mm hole. This must be a suitable fitting for a 1 Inch conduit with lock nut. Inside, the clearance around the hole is 5 mm, the maximum space for the nut is 8 mm. Then, insert your wiring through the opening and mount it to the M6 mains terminals. Observe the correct polarity. Close the conduit fitting to ensure water tightness. For strain release, two M5 threaded holes are provided; the distance between the threaded holes is 34.5 mm. Mount the housing cover by inserting it into the recess at the repeater cabinet and fastening the two M3 x 12 captive screws. Attention: For the DC power supply connection, a minimum cross section of 6.6 mm2 (≤ AWG 9) per potential is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. To ensure water-tightness of the unit, use the correct size of cable gland. F Note: Do not connect or disconnect the power cord at the mains connector while power is on. Turn off mains* power before connecting the power cord at the Extension Unit, then, engage mains again. Mains power must be interruptible with an external mains breaker (40 A). For the mains breaker, observe the local regulations of the DC provider. Page 36 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 4.3.7. Extension Unit port connection The EU connector is used to connect a cable bridge to the Remote Unit. This port provides control and RF signaling to and from the Extension Unit. Front View figure 4-17 EU (Extension Unit) connector Pin 7-Pin Assignment RF n.c. System Bus RF (if Pin installed) System Bus n.c. RF table 4-4 EU connector pinning Attention: The cable bridge connector is a push-pull connector. Ensure not to insert it at an angle into the EU connector. The connector coupler has to be inserted before the Pin-holder is pushed in. Otherwise the connectors might be damaged. The cable bridge connector provides two notches, the EU connector two noses. figure 4-18 EU connector and cable bridge M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 37 4. Commissioning Connector coupler Pin-holder figure 4-19 Mounting the EU cable bridge Take the cable bridge connector at the connector coupler and insert it carefully to the EU connector. Use the green markings to align the connector, turn it without pressure until the noses catch the notches and carefully push it at right angle into the connector. Then take the cable bridge connector (Pin-holder) and push it into the EU connector until the lock clicks. The red ‘UNLOCK’ marking must be completely covered by the connector coupler. 4.3.8. Coupling Probe The coupling probe is a QMA measurement probe that allows the measurement of the antenna output without disconnecting the antenna. The coupling is as follows: Port 700 MHz 800/850 MHz 1900 MHz 1700 MHz Page 38 Coupling dB typ. 57 56 50 48 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 4. Commissioning 4.4. Commissioning Flow-Chart Manual for Extension Unit Start Philips screwdriver Preparation Unpack EU, EU accessories and mounting kit. Mounting kit Spanner, size 13 mm Drilling machine Dowels Screw driver Screw driver Spanner, size 13 mm Grounding cable Spanner 13 mm Mechanical installation Fasten wall or pole mounting kit to wall or pole. Mechanical installation Mount EU to mounting kit, ensure sufficent air flow and avoid thermal short circuits. Electrical connections Connect grounding cable and ground the EU. RF connection Connect antenna cable to antenna port. RU connection Mount the RU - EU cable bridge to the RU and EU. PE Mains cable Connecting kit Electrical connections Connect AC (DC) power to the power cable. Ensure there is a circuit breaker between mains and RU. Mains Switch mains power on. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 39 4. Commissioning LED on? No Check mains cabling. Check mains power. Yes LED status Red Yes Internal Error Yellow LED status Yellow Red Green Spare RU available? Green No External error Contact customer service Finished setting up all RUs? No Yes Proceed to MU to set up the SW Go to MU Page 40 Output: All RUs okay. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 5. Alarms 5. Alarms 5.1. Bite and Alarms The Built-In Test concept comprises the monitoring of the power supplies, the power amplifiers, and fan units. All occurring alarms can be checked via software at the Master Unit. As soon as the software acknowledges a valid alarm, a message is transmitted to the Master Unit. If the reason for the alarm has been cleared or if the alarm should continue, a new alarm message will not be repeated. If there was an interruption of at least five seconds after acknowledgement, a new alarm message will be generated. 5.2. Troubleshooting The status of the Extension Unit can be checked via the Master Unit (for details please refer to the ION-U Site Manager software manual). Locally, the status can be checked at the LED. 5.3. Status LED Alarms For local supervision, a status LED on the connector flange of the Extension Unit provides a visual indication of possible reasons for alarms. The color of the LED indicates the severity of the alarm. Detailed alarm information is available through the ION-U software interface. Status LED Indication Alarms Green No alarm à Status ok Red Hardware failure Status LED off Mains Possible on-site measures Reboot the EU via SM software or reboot the EU by shortly interrupting mains supply. Check mains cabling. Check mains power. M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 41 6. Maintenance 6. Maintenance 6.1. General Read and observe the notices in chapter 1.2 Health and Safety. Caution: Rotating fans. Risk of injury in operation. Wear tight-fitting clothes and disconnect mains before connecting or replacing or cleaning the fan unit. Caution: The unit reaches high temperature in operation. Risk of burns by hot surface. Do not touch the unit before it has sufficiently cooled down. F Note: F Note: The Extension Unit does not require preventative maintenance measures. We recommend checking the cleanliness of the unit and in particular of the heat sink / fan(s) at appropriate intervals depending on the degree of dust and dirt at the installation site. If necessary, any dusty or dirty areas / parts should be cleaned at regular intervals, which also depend on the degree of dust and dirt at the installation site. Maintenance of the ION-U High Power EUs should be performed by replacing only components that are described in this chapter. In order to maintain the warranty, avoid unintentional damage to the seals on the modules. The spare parts list, (see chapter 7.3) includes only units that can be replaced in the field without tuning or soldering work. F Note: When sending back the unit, use appropriate packaging. Use of the original packaging for shipping the unit is strongly recommended. F Note: Defective parts should only be replaced by original parts from the supplier. All service work performed inside the housing is performed at the users own risk. F Note: Ensure the Extension Unit has been disconnected from mains power during maintenance. F Note: Label any unlabelled cables before disconnecting them to ensure correct reconnection. For most maintenance procedures, appropriate tools are required to ensure correct handling. All of these tools can be ordered from the supplier. F Note: All Extension Unit screws have a right-hand thread, and are tightened by turning the screws clockwise and loosened by turning them counterclockwise with an appropriate tool. Due to the design of the Extension Unit, the fan unit is the only component that should be replaced in the field. Please contact the supplier for replacement of any other components. Page 42 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 6. Maintenance 6.2. Replacing the Fan Unit Replacement of the fan unit is not required as a preventative measure. Only when an alarm indicates a malfunctioning of a fan, must the unit be exchanged. F Note: Please observe that the fan unit can only be replaced as a whole. Do not remove the fans separately. Read and observe chapter 1.2 Health and Safety as well as the instructions in chapter 6.1 General before starting with the replacement. 1. Switch off the Extension Unit. Make sure that mains power is disconnected for the following replacement procedure. Then, proceed as follows: 2. Unscrew the four Pan-head screws (two at each side of the cabinet) and remove the fan cover. 3. Unscrew and disconnect the fan connector and unscrew the four Panhead screws the fan plate is fastened to the cabinet. Take out the fan unit, replace it by the new one, fasten the four Pan-head screws for the fan unit, re-connect the fan connector and mount the cover to the cabinet. Fan connector M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 43 6. Maintenance 6.3. Cleaning the Heat Sink F Note: Read and observe chapter 1.2 Health and Safety as well as the instructions in chapter 6.1 General before starting with the replacement procedure. Then, proceed as follows: 1. Switch off the Extension Unit. Make sure that mains power is disconnected for the following procedure. 2. Remove the fan cover and fan unit from the Extension Unit as described in chapter 6.2 Replacing the Fan Unit. 3. Use compressed air (max. 5 bar) to blow out any dust, dirt, or other debris in the heat sink from back to front. 4. If the dirt cannot be blown out completely and parts of it stick to the ribs of the heat sink, clean the parts concerned carefully from the front using e.g. a brush. Take care that the heat sink material is not scratched or damaged. 5. After cleaning the heat sink, remount the fan unit according to chapter 6.2 Replacing the Fan Unit. Then, switch the Extension Unit back on. Page 44 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 7. Appendix 7. Appendix 7.1. Illustrations 176 824 Airflow 12.5 R4 min 150 75 Power IN Cable R1 min 21 Cable bridge to Remote Unit figure 7-1 ION-U EU H 7P/80-85P/17P/19P required space M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 45 7. Appendix 7.2. Specifications This manual is valid for the following Extension Units: ID No 7698401-xxxx* Denomination ION-U EU H 7P/80-85P/17P/19P * The xxxx suffix is the identifier for the specific configuration of the Extension Unit. Please refer to the ION-U EU H 7P/80-85P/17P/19P data sheet for the ION-U HP EU specifications. 7.3. Spare Parts Maintenance of the EU should be performed on an FRU (Field Replaceable Unit) basis only. If any FRU not contained in the following list needs to be replaced, please contact customer service for additional instructions. Designation: Fan Unit M2-Cabinet ID No 7661556-xx The manufacturer reserves the right to replace the spare parts listed above by equivalent substitutes. F Note: Only the spare part listed above is a FRU and can be replaced by the user. For replacement of any other parts, please send the entire Extension Unit back to the manufacturer. 7.4. List of Changes Version M0200A9B M0200A9C Page 46 Changes - chapter 1.4 adjusted Release Date 30-June-2015 08-July-2015 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U 8. Index 8. Index Alarms Bite and Alarms ............................................... 41 EU .................................................................... 41 Handling of Alarms .......................................... 41 List ................................................................... 41 Status LED....................................................... 41 ANT RF ................................................................ 25 Health and Safety ................................................... 7 Block Diagram ION-U EU H 7P/80-85P/17P/19P .................... 15 CE Declaration of Conformity (DoC)..................... 11 Cleaning the Heat Sink ......................................... 44 Commissioning General ............................................................ 16 CommScope ......................................................... 11 Compliance............................................................. 8 Connections Antenna ........................................................... 28 Connector Panel .............................................. 24 Connectors DC Mains ......................................................... 26 Probe ............................................................... 25 Contact Addresses, Customer Support .......... 12, 13 Coupling Port ........................................................ 38 DC Mains Connector ............................................ 35 Declaration of Conformity (DoC)........................... 11 Extension Unit connector...................................... 25 Extension Unit Port ............................................... 37 Illustrations ........................................................... 45 Installation Distance between Units ................................... 18 Electrical .......................................................... 23 Mechanical ...................................................... 16 Mains Connector ............................................ 25, 33 Mains Power Connection...................................... 33 Maintenance ......................................................... 42 Mounting Pole with brackets............................................ 21 Pole with screw bands ..................................... 20 Wall.................................................................. 19 Pole Mounting ................................................ 20, 21 Property Damage Warnings ................................... 7 Replacement of Fan Unit ...................................... 43 Spare Parts .......................................................... 46 Status LED ........................................................... 25 Troubleshooting.................................................... 41 Wall Mounting ....................................................... 19 Grounding (Earthing) ............................................ 27 Grounding Bolt...................................................... 25 M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION®-U Page 47
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : Tech Docu AMBG Create Date : 2015:07:08 16:52:54+02:00 Draft Date : D:20130409 Keywords : M0200A Modify Date : 2015:07:08 16:53:40+02:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2015:07:08 16:53:40+02:00 Creator Tool : Acrobat PDFMaker 10.1 für Word Document ID : uuid:8e9363f8-eaba-49ec-9f69-cd27925e86c7 Instance ID : uuid:55f7f614-6ae6-4627-9c4f-ec9d60f89080 Subject : 3 Format : application/pdf Title : User's Manual for ION-U Creator : Tech Docu AMBG Producer : Adobe PDF Library 10.0 Source Modified : D:20150708145239 Company : CommScope Draft 0020date : D:20130409 Page Layout : OneColumn Page Mode : UseOutlines Page Count : 48EXIF Metadata provided by EXIF.tools