                            Installation Instruction  The Remote Unit, Extension Unit or Master Unit has to be mounted by proffessionel / special trained installer.  1.1.  HIGH POWER RU MECHANICAL INSTALLATIONN 1.1.1. General Read the health and safety warnings in chapter 1.3. 1. Warning: Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2.  WARNING: IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT. Installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components. The supporting wall should be solid wood or concrete using appropriate screws and dowels (wall anchors). 3. Warning: It is recommended to use the mounting hardware delivered by the manufacturer only. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded.  Note:  Exceeding the specified load limits may cause the loss of warranty! 4.  Warning: The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 5. Caution: Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation. 6. Note: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can penetrate into the unit through these cables. 7. Note: Observe all additional rules or restrictions regarding mounting that apply to specific Remote Unit types. 8. Note: Observe all additional rules or restrictions regarding mounting that apply to specific Remote Unit types. For details refer to the mechanical specifications in the data sheet for the unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be maintained, as shown in the following illustrations:
                            9. A spacing of 40 mm (1.66 inch) around the unit is required. 10. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) must be provided. Do not block these air inlets and outlets when mounting the remote unit. The size of each opening must equal at least 12 x 12 cm (144 cm2). Ensure that there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques must be observed for certain mounting procedures according to the following table: Type  Tallow-drop screws  Hex nuts  Spacing bolts  PG (plastic)  PG (aluminium) Thread M 4  M 8  M 4  M 8  PG 13.5  PG 29 Specified torques 3.3 Nm  27 Nm 2.3 Nm  27 Nm 3.75 Nm  10 Nm table Fehler! Kein Text mit angegebener Formatvorlage im Dokument.-1 Specified torques The mounting procedures for a stand-alone remote unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see the separate accessories manual.
                            1.2. ELECTRICAL INSTALLATION 1.2.1. General Read the health and safety warnings in chapter 1.3.  1. Warning: This unit contains dangerous voltages. Loss of life, severe personal injury, or property damage can be the result if the instructions contained in this manual are not followed. 2. Caution: It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Caution: Although the remote unit is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the antenna connectors of the remote unit for protection against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install additional lightning protection. 4. Caution: If the mains connector of the remote unit is not easily accessible, a disconnect device in the mains power circuit must be provided within easy reach. 5. Caution: Before connecting or disconnecting the mains connector at the remote unit, ensure that mains power supply is disconnected. 6. Caution: Make sure that an appropriate circuit breaker acting as a disconnect device (as required by IEC/EN60950-1) and an overcurrent limiting device are connected between mains power and the Remote Unit. 7. Caution: A connection of the mains supply to a power socket requires the power socket to be nearby the remote unit. 8. Caution: Incorrectly wired connections can destroy electrical and electronic components. 9. Caution: To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Note: Use an appropriate torque wrench to tighten the 7/16 DIN-type (1 ¼ -inch opening) antenna connectors to a coupling torque of 25 N-m / 19 ft lb. Torque wrench item no. 244377, available from the CommScope e-catalog, is recommended. Do NOT use your hands or any other tool (e. g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit or increased PIM. 11. Caution: For unstabilized electric networks, which frequently generate spikes, the use of a voltage limiting device is advised.
                            12. Caution: The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, installation of an additional medium (via local supply connection) and/or coarse protection (external surge protection) is recommended depending on the individual application in order to avoid damage caused by overcurrent. 13. Caution: Observe the labels on the front panels before connecting or disconnecting any cables.
                            1.3.  HEALTH AND SAFETY WARNINGS 1. Danger: Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger:  Laser radiation! Do not stare into the beam; do not view it directly or with optical instruments. 3. Danger: Before opening the unit, disconnect mains power. 4. Danger:  Due to power dissipation, the remote unit may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Use caution when servicing the unit. 5. Warning: Read and obey all the warning labels attached to the unit. Make sure that all warning labels are kept in a legible condition. Replace any missing or damaged labels. 6. Warning: It is the responsibility of the network provider to implement prevention measures to avoid health hazards associated with radiation from the antenna(s) connected to the unit. 7. Warning: Make sure, access is restricted to qualified personnel. 8. Warning: Only licence holders for the respective frequency range are allowed to operate this unit. 9. Warning: Make sure the repeater settings are correct for the intended use (refer to the manufacturer product information) and regulatory requirements are met. 10. Warning: Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts, which are not sold or recommended by the manufacturer. This could cause fires, electric shock, or other injuries. 11. Warning: For installations, which have to comply with FCC RF exposure requirements, the antenna selection and installation must be completed in a way to ensure compliance with those FCC requirements. Depending on the RF frequency, rated output power, antenna gain, and the loss between the repeater and antenna, the minimum distance D to be maintained between the antenna location and human beings is calculated according to this formula:  ]/[][][24cmmWmWcm PDPD  where  P (mW) is the radiated power at the antenna, i.e. the max. rated repeater output power in addition to the antenna gain minus the loss between the repeater and the antenna.  PD (mW/cm²) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B) for general population / uncontrolled exposures which is o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz o 1 for frequencies from 1500MHz to 100.000MHz
                           RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). 12. Warning: For installations which have to comply with Europe an EN50385 exposure compliance requirements, the following Power Density limits/guidelines (mW/cm²) according to ICNIRP are valid: o 0.2 for frequencies from 10 MHz to 400 MHz o F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz o 1 for frequencies from 2 GHz to 300 GHz 13. Caution: Keep operating instructions within easy reach and make them available to all users. 14. Caution: Corresponding local particularities and regulations must be observed. For national deviations, please refer to the respective documents included in the manual CD that is delivered with the unit. 15. Caution: Although the remote unit is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the repeater’s antenna connectors for protection against atmospheric discharge. 16. Caution: ESD precautions must be observed! Before commencing maintenance work, use the available grounding (earthing) system to connect ESD protection measures. 17. Caution: Installation of this equipment is in full responsibility of the installer, who has also the responsibility, that cables and couplers are calculated into the maximum gain of the antennas, so that this value, which is filed in the FCC Grant and can be requested from the FCC data base, is not exceeded. The industrial boosters are shipped only as a naked booster without any installation devices or antennas as it needs for professional installation. 18. Note: For a Class A digital device or peripheral: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.  19. Note: This unit complies with European standard EN60950.
                            Equipment Symbols Used  Please observe the meanings of the following symbols used in our equipment:  Symbol Compliance Meaning --- FCC WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.  --- Alert sign to R&TTE To be sold exclusively to mobile operators or authorized installers – no harmonised frequency bands, operation requires license Intended use: EU and EFTA countries  --- Indicates conformity with the R&TTE directive 1999/5/EC certified by the notified body no. 0700.