Angelcare Canada AC201RX AC200, AC200R, AC201 & AC201R PARENT UNITS User Manual AC201 Manual international

Angelcare Monitors Inc. AC200, AC200R, AC201 & AC201R PARENT UNITS AC201 Manual international

Users manual in English only

®Movement & Sound MonitorMovement & Sound Monitor (Rechargeable)Moniteur de mouvements et sons Moniteur de mouvements et sons (Rechargeable)Intercomunicador de sonidos y movimientosIntercomunicador de sonidos y movimientos (Recargable)Geräusch– und BewegungsmelderGeräusch– und Bewegungsmelder (Wiederaufladbarer)Vigilante de Movimento e Som Vigilante de Movimento e Som (Recarregável)Babyfoon & BewegingsmonitorBabyfoon & Bewegingsmonitor (Oplaadbare)Bevegelses- og lydvarsler for barneværelsetBevegelses- og lydvarsler for barneværelset (Oppladbar)Rörelse- och ljudmonitor för barnkammarenRörelse- och ljudmonitor för barnkammaren (Laddningsbar)Lyd- og bevægelsesmonitor Lyd- og bevægelsesmonitor (Opladelig )Vauvan itkuhälytin ja liikemonitoriVauvan itkuhälytin ja liikemonitori (Ladattava)AC201AC201-R
2TABLE OF CONTENTSWarranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Easy Steps to Operate Your Angelcare®Monitor  . . . . . . . . . . .4Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Instructions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Testing Your Angelcare®Monitor  . . . . . . . . . . . . . . . . . . . . . . . .5Operating tips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Distributors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43TABLE DES MATIÈRESGarantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 étapes faciles à suivre pour utiliser votre moniteur Angelcare® .8Mises en garde  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9Vérification de votre moniteur Angelcare® . . . . . . . . . . . . . . . . .9Conseils pratiques  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9Diagnostic des pannes   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Distributeurs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43ÍNDICEGarantía . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115 pasos sencillos para usar el Intercomunicador Angelcare® . .12Advertencias  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Instrucciones  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Prueba de funcionamiento del Intercomunicador Angelcare® . .13Recomendaciones  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Solución de problemas  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Distribuidores  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43INHALTGarantie  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 einfache Schritte zur Benutzung Ihres Angelcare®Geräusch-und Bewegungsmelders  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Sicherheitshinweise  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Gebrauchsanweisung  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Testen des Angelcare®-Geräusch- und Bewegungsmelders  . . .17Tipps zum Betreib des Angelcare®-Geräusch-und Bewegungsmelders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Problemlösungen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Vertreiber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43ÍNDICEGarantia  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195 Passos fáceis para utilizar o seu Vigilante Angelcare® . . . . . .20Conselhos de segurança  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Instruções  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Teste ao seu Vigilante Angelcare® . . . . . . . . . . . . . . . . . . . . . . .21Conselhos de utilização  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Detecção e reparação de problemas . . . . . . . . . . . . . . . . . . . . .22Informações sobre o vendedor  . . . . . . . . . . . . . . . . . . . . . . . .43INHOUDSOPGAVEGarantie  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23Leer uw Angelcare®monitor gebruiken in 5 eenvoudige stappen  .24Veiligheidswaarschuwingen  . . . . . . . . . . . . . . . . . . . . . . . . . . .25Instructies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25Testen van de Angelcare®Babyfoon en Bewegingsmonitor . . . .25Tips voor het gebruik . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25Problemen & oplossingen  . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Importeurs/distributeurs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43INNHOLDSFORTEGNELSEGaranti . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275 enkle trinn for bruk av ditt Angelcare®varselapparat . . . . . . . . . . .28Sikkerhetsadvarsler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Instruksjoner  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Testing av ditt Angelcare®varselapparat . . . . . . . . . . . . . . . . . .29Brukstips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Problemløsning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Forhandlere  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43INNEHÅLLSFÖRTECKNINGGaranti . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315 enkla steg till användning av din Angelcare®monitor . . . . . . .32Säkerhetsföreskrifter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33Instruktioner  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33Att testa din Angelcare®monitor  . . . . . . . . . . . . . . . . . . . . . . .33Tips för användning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33Felsökning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34Återförsäljare  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43INDHOLDSFORTEGNELSEGaranti . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355 nemme punkter til betjening af din Angelcare®monitor . . . . .36Sikkerhedsadvarsler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Instruktioner  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Afprøvning af din Angelcare®monitor  . . . . . . . . . . . . . . . . . . .37Betjeningstips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Fejlfinding  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38Distributører  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43SISÄLLYSLUETTELOTakuu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39Angelcare®-monitorisi käytön 5 helppoa vaihetta  . . . . . . . . . . .40Varoitukset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41Ohjeet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41Angelcare®-monitorin testaus . . . . . . . . . . . . . . . . . . . . . . . . . .41Vihjeitä laitteen käyttöön  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41Vianetsintä . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42Maahantuojat  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
3®Figure 1Figure 2Correct IncorrectPOSITION OF SENSOR PAD UNDER MATTRESSTMParents UnitNursery UnitAdapter socketMovement sensitivity adjustment dialBattery compartmentBackup battery compartment9 Volt AC Adapters (2)AntennaMovement indicator (flashing green)Alarm indicator (flashing red)MicrophoneVolume controlselector Low battery indicator(flashing orange)Power On/Off & Channel A or B selectorPower On indicator (green LED)Low battery indicator (flashing orange)Power ON indicator(green LED)Power ON/OFF &Channel A or BselectorSound levelindicators (yellow LEDs)SpeakerSensor Pad Figure 6Alarm sounder"Tic" On/Off, Sound & Movement,Sound only functionsAdapter socketSensor Pad socketPoor sensing indicator(flashing orange)Sensor Pad cord Crib CribSensor Pad Figure 3 Figure 4Figure 4AFigure 5NURSERY UNIT (TRANSMITTER) PARENTS UNIT (RECEIVER)Antenna ONE YEAR LIMITED WARRANTYAngelcare®warrants to the original owner of this product that the Angelcare®Movement & Sound Monitor (Model AC201) and the Angelcare®RechargeableMovement & Sound Monitor (Model AC201-R) is free from defects in materials and workmanship for a period of one (1) year from the date of the originalpurchase. If this monitoring system fails to function properly when used as directed under normal conditions, within the one year period, Angelcare®willeither repair or replace the product at our option free of charge, when it is returned complete and in its original packaging, prepaid postage, and insured toyour distributor (see page 43).The product must be accompanied by a proof of purchase, either a bill of sale, receipted invoice, or other proof that the monitoring system is within thewarranty period. Angelcare®will bear the cost of repairing or replacing the product and shipping it back to you.This warranty does not apply to a product that has been damaged as a result of improper maintenance, accidents, improper voltage supply or other misuse.The warranty is also void if the owner repairs or modifies the product in any way. Angelcare®is not liable for any incidental or consequential damages withregard to this product. The warranty also excludes any liability other than what is stated above. No other warranties are given.LEGAL RIGHTS VARY FROM COUNTRY TO COUNTRY. SOME COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL ORCONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.WE ARE NOT IN ANY WAY RESPONSIBLE FOR ANY OUTCOME RESULTING FROM USE.IMPORTANT! This Angelcare®Monitor is a personal care product. Please do not return this product to the store. If you have questions or need help, pleasecall your distributor (see page 43) before returning this product to the retailer.
45 EASY STEPS TO OPERATE YOUR ANGELCARE®MONITORSTEP 1. SENSOR PAD Place Sensor Pad lengthwise under crib mattress, directly under where baby sleeps (Figures 1 and 2). Printed side of Sensor PadMUST face up. DO NOT place any bedding or linen between crib mattress and Sensor Pad.Sensor Pad must rest on a firm surface. If your crib has a spring base, place a piece of plywood measuring at least 400 mm x600 mm x 6 mm (16" x 24" x 1/4") on spring base. If your crib has a plywood base, your mattress support is firm enough toproperly use monitor. STEP 2. NURSERY UNIT (TRANSMITTER)• Insert 4 AAA batteries into Nursery Unit (for battery backup in case of power failure).• Connect Sensor Pad to Nursery Unit (Figures 3 and 6).• On the back of the Nursery Unit, select 1 of the 3 functions of how you want to monitor your baby from the Parents Unit:Sound & Movement: To hear sounds, see sound lights and hear a "Tic" sound with every movement baby makes.Tic off: Same as Sound & Movement function BUT without the "Tic" sound.Sound Only: To hear sounds and see sound lights on Parents Unit.• Connect AC adapter to Nursery Unit and plug adapter into an electrical outlet.NOTE: The sensitivity adjustment has been preset. DO NOT ADJUST UNLESS NECESSARY. If poor capture of movement (orangeflashing light) or false alarm occurs, consult the Movement Sensitivity Adjustment section.STEP 3. PARENTS UNIT (RECEIVER)Model AC201: Insert 4 AAA batteries into Parents Unit. Or, connect AC adapter to Parents Unit and plug adapter to an electrical outlet.Model AC201-R: The pre-installed NiCad rechargeable batteries need to be charged for 15 hours continuously before first-timeuse. To charge, connect the AC adapter to the Parents Unit. Plug AC adapter to an electrical outlet (Figure 4). The batteries willcharge as long as it is connected to a powered AC adapter. The position of the switches will not effect charging.For longest battery life, only recharge the Parents Unit when the orange Low Battery light flashes.NOTE: Only the Parents Unit is rechargeable in Model AC201-R.• Adjust the volume control to the desired level.STEP 4. TO USE MONITORPlace baby in crib and switch both units ON by selecting either channel A or B. If reception is not clear, switch to other channel.Make sure both units are on the same channel. When removing baby from crib, switch Nursery Unit to the OFF position. If youforget to switch OFF, a "pre-alarm Tic" will sound after 15 seconds as a reminder.To avoid feedback (whistling sound), keep both units at least 3 meters apart (10 feet).STEP 5. BATTERY MODE• When unplugging AC adapter from each unit, make sure unit is switched OFF. Otherwise, unit will revert to battery mode.•  The monitor will revert to battery mode during a power failure only if batteries are inserted in both units. Insert batteries into NurseryUnit and Parents Unit for Model AC201. When orange Low Battery indicator flashes, change batteries promptly (or recharge ParentsUnit for Model AC201-R).Note: • Test your Angelcare®Monitor BEFORE first-time use and then on a periodic basis.• When monitor is in use, DO NOT use crib mobile or other crib accessories that produce vibrations. Alarm will not sound as monitoris still detecting movement.• The Angelcare®monitor is perfectly safe. The Sensor Pad and its cord are entirely passive. They carry no electrical current and donot radiate any form of energy. The Nursery Unit emits only very low power radio signals through its antenna. These signals do notpresent a safety hazard.• Your monitor can be used in any crib or sleeping area (that has no motion or vibration) designed to safely hold a baby. It must have afirm flat bottom greater than the size of the Sensor Pad - 260 mm x 406 mm (10" x 16"). DO NOT use in a rocking cradle. • If you have questions or need help, please call your distributor, see page 43.
5®Warnings• This product is NOT a medical device nor a device to preventcases of Sudden Infant Death Syndrome (SIDS).• This product is NOT a substitute for direct supervision of yourbaby. Check your baby’s activities at regular intervals. Monitoringof premature babies, or those considered to be at risk, should becarried out only under the supervision of a doctor or healthprofessional.• The Sensor Pad may detect movement from many sources fromboth inside and outside your baby’s room, for example: fans,washing machines, loud music, etc. Ensure that all vibrationsources are eliminated before using the Angelcare®Monitor.Avoid contact with crib when monitor is in use. Refer to theMovement Sensitivity Adjustment and Troubleshootingsections.• ALWAYS place both units on flat surface in an upright position,away from baby’s reach.• DO NOT touch the end of the adapter cord when plugged into anelectrical outlet.• The Angelcare®Monitor uses public airwaves to transmit signals.The Parents Unit may pick up signals or interference from othernursery monitors in your area. Your monitor may even be pickedup by other households. To protect your privacy, make sure bothunits are in the OFF position when not in use.•  This product should be serviced by qualified personnel. There areno user serviceable parts inside monitor. Refer all servicequestions to your distributor (see page 43).InstructionsRETAIN INSTRUCTIONS: Keep user’s manual for future reference.WATER, MOISTURE AND HEAT DAMAGE: Keep all 3 componentsaway from water (sink, bath tub, swimming pool) and places that emitheat (stove, radiator).VENTILATION: ALWAYS place both units on flat surface in an uprightposition so that air can flow freely around them. AC POWER SOURCE: Use ONLY the AC adapters supplied with theAngelcare®Monitor. CORD PROTECTION: Avoid damage to the Sensor Pad cord and to theadapter cords. Route cords so that they are not likely to be walked onor pinched by items placed upon or against them. CLEANING: Disconnect all units before cleaning. DO NOT immerse inwater. Use a dry cloth to keep monitor free from dust. DO NOT spraywith cleaning products or solvents. Wipe Sensor Pad with a veryslightly damp cloth with an antiseptic or mild detergent. OBJECT AND LIQUID ENTRY: Care should be taken so that objects donot fall onto units and that liquids are not spilled into either unit orSensor Pad through their openings.NON-USE PERIODS: When not using monitor for long periods,remove the batteries from both units and disconnect the AC adaptersfrom electrical outlet.Testing Your Angelcare®MonitorNote: Test your Angelcare®Monitor BEFORE first-time use and thenon a periodic basis.The Angelcare®Monitor can be used outside of the crib, in a differentsleeping area. Test monitor when moving Sensor Pad to a new locationto ensure sensitivity is adjusted correctly to the new padding ormattress. Consult the Movement Sensitivity Adjustment section.Step 1. On the Nursery Unit, switch to the "Sound Only" function. Havesomeone else speak into the Nursery Unit or place a radio nearNursery Unit. You should hear sound from the Parents Unit. If there isno sound, refer to the Troubleshooting section. Make sure that bothunits are on the same channel, either both on A or B. If reception isnot clear, switch to other channel. Step 2. Test monitor to detect movement. Switch Nursery Unit to the"Sound & Movement" function. The Movement indicator light will flashred, green and then emit a single "Tic" sound. Gently pat your hand onthe mattress. The green light will continue to flash with your everymovement. Remove hand from mattress. Due to no movement, a "pre-alarm Tic" sound will emit after 15 seconds. 5 seconds later, the alarmwill sound and the red light will flash continuously.NOTE: If alarm does not sound, the Sensor Pad may be detecting acontinuous vibration from the floor, a strong draft or the crib is beingtouched. Avoid contact with crib when monitor is in use. Place cribnear a solid supporting wall and away from strong air currents. Thesensitivity of the Sensor Pad may need to be reduced, consult theMovement Sensitivity Adjustment section. Step 3. To stop alarm, pat your hand lightly on mattress for SensorPad to redetect movement. The red Alarm indicator light on theNursery Unit will continue to flash 1 minute (Figure 3).Step 4. Verify that the battery mode is functional by operating bothunits without the AC adapters. The green Power light should appear onboth units. Parents Unit: When orange Low Battery indicator light appears,replace batteries promptly for Model AC201. For Model AC201-R,recharge Parents Unit. Nursery Unit: When orange Low Battery indicator light appears arapid "clicking" is heard, replace batteries promptly. If not, the lightwill eventually turn red and the monitor will stop working.Operating TipsMovement Sensitivity Adjustment The sensitivity adjustment dial has been preset to suitmost situations. However in certain circumstances,the sensitivity may not be ideal. DO NOT increasesensitivity unless false alarms occurs and you havefollowed the advice in the Troubleshooting section forfalse alarms. Make a note of the pre-set position of the dial should youwish to return to it.The movement indicator light on the Nursery Unit will flash orangewhen monitor barely detects movement. This could be a result of:baby being in a very deep sleep or baby having moved away fromSensor Pad to edge of crib. If alarm does NOT sound, no adjustmentof sensitivity is required. If the Movement indicator light flashesorange most of the time with baby directly over the location of theSensor Pad, a false alarm may occur. If this happens, adjust thesensitivity. To adjust the sensitivity, place baby on mattress or padding and waituntil baby is asleep and has settled. This will ensure a more precisetuning. Set dial to 5, then proceed to lower sensitivity until orange lightflashes on Nursery Unit. Then slowly increase slightly until green lightappears. Add 1/2 point to set the sensitivity level (ex. If green lightappears at 3, then set dial at 3.5). Retest monitor.Channel selection for sound receptionMake sure that both units are on the same channel, either both on Aor B. If reception is not clear, switch to other channel. If interferencepersists, consult the Troubleshooting section. NOTE: This monitoring system is NOT equipped with an out-of-rangeindicator. No sound will be received if the Parents Unit and NurseryUnit are too far apart. Yellow Sound LightsThe four Sound Lights allow you to see baby’s sounds. The louder thesounds from baby, the more lights appear.012345
6Problem Possible Cause SolutionFalse alarms.Alarm will not sound.Movement indicator light is flashingorange (monitor is barely detectingmovement).No sound is being transmitted.Power ON indicator (green light) doesnot light up.Very weak reception.Static, distortion, interference(interference from other monitors,wireless phones, walkie-talkies, etc…).Feedback (loud noises emitted fromParents Unit).TROUBLESHOOTING•Baby was removed from crib and Nursery Unit was notswitched OFF.•Sensor Pad cord not connected properly to Nursery Unit.•Sensor Pad is not in full contact with crib mattress, or cribmattress is not resting on a hard surface.•Baby has moved away from Sensor Pad, to the edge of the crib.•Nursery Unit is detecting movement when crib is beingtouched.•Nursery Unit is detecting movement from outside the cribsuch as motorized devices, strong drafts, etc…•Sensitivity is set too high.•Sensor Pad is not in full contact with crib mattress, or themattress is not resting on a firm surface.•Baby is in a very deep sleep or has moved away from SensorPad, to the edge of the crib.•Units are too far apart.•Batteries are low or improperly installed.•AC adapters are not connected properly or electrical outlet isout of order.•One of the units is not ON.•Units are set to different channels.•Batteries are low or improperly installed.•AC adapters are not connected properly or electrical outletis out of order.•One of the units is not ON.•Units are too far apart.•One or both units are placed near a large metal mass.•One or both units are not in the upright position.• Batteries are low.•Parents Unit is out of range.•  Units are not set to the same channel, either both on channelA or B.•  Parents Unit located near motorized devices, fluorescentlights, television, etc…•Units are too close to each other.•Turn Nursery Unit to the OFF position.•Verify the connection between the Sensor Pad andNursery Unit. Unplug  and reconnect the cord.•Make sure there is no bedding between mattress andSensor Pad.  Sensor Pad must rest on a firm surface.  Ifcrib has a spring base, place a piece of plywood measuringat least 400 mm x 600 mm x 6 mm (16" x 24" x .25") onspring base. If crib has a plywood base, mattress support isfirm enough. •Make sure Sensor Pad is positioned lengthwise in crib.Sensitivity may need to be adjusted, consult theMovement Sensitivity Adjustment section.•Avoid contact with the crib when monitor is ON. •Place crib near a solid supporting wall to avoid SensorPad from detecting movement from outside crib.  •You may need to decrease the sensitivity, consult theMovement Sensitivity Adjustment section.•Make sure there is no bedding between mattress andSensor Pad. Sensor Pad mustrest  on a firm  surface. If cribhas a spring base, place a piece of plywood measuring atleast 400 mm x 600 mm x 6 mm (16" x 24" x .25") on springbase. If crib has a plywood base, mattress support is firmenough. •Make sure Sensor Pad is positioned lengthwise in crib.Consult Movement Sensitivity Adjustment section.•Bring Parents Unit closer to Nursery Unit.•Check / replace batteries or recharge Parents Unit (ModelAC201-R only).•Check connections or change to another electrical outlet.•  Ensure both units are ON.•Make sure both units are on the same channel, either bothA or B.•  Check / replace batteries or recharge Parents Unit (ModelAC201-R only).•  Check connections or change to another electrical outlet.• Make sure both units are ON and on the same channel,either both A or B.•  Bring units closer together.•  Change the position of one or both units.•Place units on flat surface away from baby’s reach.• Replace the batteries or recharge Parents Unit (ModelAC201-R only).•  Bring units closer together.• Make sure both units are ON and on the same channel,either both on channel A or B. • Rotate Parents Unit or move it away from source ofinterference.•  Move units farther apart (at least 3 meters / 10 feet apart).•  Decrease volume on Parents Unit.AC power sourceModel AC201: The AC adapters should be used whenever possible toextend the battery life. Batteries can be kept in units while using ACpower source. Model AC201-R: Use AC adapter on Nursery Unit whenever possibleto extend the battery life. For Parents Unit, use AC adapter only tocharge NiCad batteries. Replacing the rechargeable batteries (Model AC201-R only)When the NiCad batteries in the Parents Unit will not charge or onlyhold their charge for a short period of time, batteries need to bereplaced. You can buy another set of NiCad batteries. In that case,bring old NiCad batteries to ensure proper ones are bought. Or, theParents Unit can also accommodate NiMh batteries. They require 30hours of charging time before first-time use. They provide an evenlonger battery life. Unscrew the battery compartment door on the Parents Unit. Removeold NiCad batteries. Insert new rechargeable batteries. Screw in thebattery compartment door. Plug the Parents Unit into an electricaloutlet. Allow new batteries to charge continuously for 15 hours.
44INFORMATION TO USERThis device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1) This device may not cause harmful interference,and (2) This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules.  These limits are designedto provide reasonable protection against harmful interference in a residential installation.  This equipment generates and can radiate radio frequency energyand, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guaranteethat interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can bedetermined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.• Reorient or relocate the receiving antenna• Increase the separation between the equipment and receiver• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected• Consult the dealer or an experienced radio/TV technician for helpAny changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.L’UTILISATION DE CE DISPOSITIF EST AUTORISÉE SEULEMENT AUX CONDITIONS SUIVANTES: (1) IL NE DOIT PAS PRODUIR DE BROUILLAGE, ET (2)L’UTILISATEUR DU DISPOSITIF DOIT ÊTRE PRET À ACCEPTER TOUT BROUILLAGE RADIOÉLECTRIQUE REÇU, MÊME SI CE BROUILLAGE EST SUSCEPTIBLEDE COMPROMETTRE LE FONCTIONNEMENT DU DISPOSITIF.User Guide StatementAngelcare Monitors Inc. declares that the AC201 and AC201-R are in conformity with all essential requirements and other relevant provisions of the R&TTE Directive (1999/5/EC).:This product is marked with  which signifies conformity with Class II product requirements specified in the R&TTE Directive.Déclaration du guide de l’utilisateurLes moniteurs Angelcare Inc. déclarent que ses modèles AC201 et AC201-R sont conformes à toutes les exigences essentielles et autres dispositions pertinentes inclues dans la directiveR&TTE (1999/5/EC). :Ce produit porte la marque  signifiant sa conformité aux exigences spécifiées dans la directive R&TTE pour un produit de classe II.Certificación para el usuarioLa empresa Angelcare Monitors Inc. certifica que los equipos AC201 y AC201-R se ajustan a todos los requisitos esenciales y demás disposiciones de la Directiva de R&TTE (1999/5/CE).:Este producto lleva el sello  , lo que significa que cumple con los requisitos de Clase II expuestos en la Directiva de R&TTE.Für die GebrauchsanweisungAngelcare Monitors Inc. bestätigt, dass die Modelle AC201 und AC201-R sich in Übereinstimmung mit allen relevanten Bestimmungen der R&TTE Direktive befinden (1999/5/EC).:Dieses Produkt ist mit  gekennzeichnet.  Dies bedeutet, dass es mit Class II Produktbestimmungen, die in der R&TTE Direktive festgeschrieben sind, übereinstimmt.Atestado do guia do usuárioAngelcare Monitors Inc. declara que os produtos AC201 e AC201-R estão conformes a todas as exigências essenciais e outras providências pertinentes da diretiva R&TTE (1999/5/EC).: Este produto está marcado com  o que significa a conformidade exigências do produto de Classe II especificadas na diretiva R&TTE. Bepalingen GebruikshandleidingHierbij verklaart Angelcare Monitors Inc. dat de AC201 en AC201-R voldoen aan alle essentiele voorwaarden en andere van toepassing zijnde regels, genoemd in de R&TTE Directive(1999/5/EC).:Dit artikel draagt het  kenmerk, wat aangeeft dat het voldoet aan alle Klasse II productvoorwaarden, zoals aangegeven in de R&TTE Directive.BrukerveiledningsmeldingAngelcare Monitors Inc. erklærer at AC201 og AC201-R er i overenstemmelse med alle vesentlige krav og andre relevante forskrifter, ifølge R&TTE direktivet (R&TTE Directive)(1995/5/EC).:Produktet er merket med  i overenstemmelse med Class II produktkrav  som spesifisert i R&TTE direktivet.Användarhandbok - UttalandeAngelcare Monitors Inc. intygar att AC201 och AC201-R är i enlighet med alla väsentliga krav och övriga relevanta bestämmelser utgivna av R&TTE Directive (1999/5/EC).:Denna vara är markerad med  vilket bevisar överensstämmelse med kraven för Class II varor, specifierade i R&TTE Directive.Erklæring til BrugervejledningAngelcare Monitors Inc. erklærer, at AC201 og AC201-R er i overensstemmelse med alle nødvendige krav og andre relevante forholdsregler i R&TTE Direktivet (1999/5/EC).:Dette produkt er markeret  , hvilket tilkendegiver overensstemmelse med Klasse II produktkrav, som specificeret i R&TTE Direktivet.Käyttäjäoppaan VakuutusAngelcare Monitors Inc. vakuuttaa, että AC201 ja AC201-R ovat kaikkien radio- ja telepäätelaitteita koskevan direktiivin (1999/5/EC) olennaisten vaatimusten ja muiden asiaankuuluvienmääräysten mukaisia.:Tämä tuote on varustettu  merkinnällä, joka on osoitus radio- ja telepäätelaitteita koskevassa direktiivissä mainittujen luokan II tuotteita koskevien vaatimusten mukaisuudesta.0165016501650165016501650165016501650165

Navigation menu