Anker Technology T9143 BodySense Smart Scale Spot User Manual

Anker Technology Co., Limited BodySense Smart Scale Spot

User Manual

Download: Anker Technology T9143 BodySense Smart Scale Spot User Manual
Mirror Download [FCC.gov]Anker Technology T9143 BodySense Smart Scale Spot User Manual
Document ID3508358
Application IDOM/BgXzyewHG6RELPmJBcQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize94.87kB (1185860 bits)
Date Submitted2017-08-11 00:00:00
Date Available2017-08-11 00:00:00
Creation Date2017-07-28 10:40:03
Producing SoftwareAdobe Acrobat Pro 9.0.0
Document Lastmod2017-07-28 10:40:03
Document TitleUser Manual
Document CreatorAdobe Acrobat Pro 9.0.0

What’s In the Box
BodySense Smart Scale Spot AAA Battery (×3)
BodySense Smart Scale Spot AAA Battery (×3)
Safety Sheet
Owner's Manuel &
Quick Start Guide
Inserting the Batteries
Health & Wellness
Turn the scale over and place it on a flat surface.
Open the
battery door
and insert three AAA batteries. Make sure the
Safety Sheet
Owner's Manuel &
positive and negative
ends
are
facing the correct polarity directions
Quick
Start
Guide
marked in the battery compartment.
- The digits “
” will show on the LED display.
Close the battery door and wait until the digits “ ” are shown on the
LED display.
Owner’s Manual
BodySense Smart Scale Spot
will appear on the LED display when the batteries are low.
Replace all three batteries at the same time. Do not mix new and
used batteries.
Selecting the Measuring Unit
Press the Unit button on the bottom of the scale to cycle through and
select the measuring unit: Pound / Stone / Kilogram. The measuring unit
can be selected from within the EufyLife app as well.
Installing the EufyLife App and Pairing
Download the EufyLife app from the App Store (iOS devices) or Google
Play (Android devices).
Enable Bluetooth on your smartphone or tablet.
Open the EufyLife app and follow the on-screen instructions to pair the
scale with your device.
- Once paired, the app and scale will automatically connect the next
time the app is opened.
For FAQs and more information, please visit:
www.eufylife.com
EufyLife
Bluetooth ON
Status Icon
Flashing
Solid
Product Number T9143
51005000625 V02
Smart Scale Spot
Indication
Pairing
Connected
T
- This scale is compatible with devices running iOS 8.0 and above or
Android 4.3 and above.
- Do not pair the scale from your smartphone’s Bluetooth menu. Use
the EufyLife app to pair the scale with your smartphone.
Measuring with the Eufylife App
Before taking your first measurement, you will need to create and set up a
user ID in the EufyLife app. It is possible to create up to 16 user IDs.
Place the scale on a hard and flat surface.
Open the EufyLife app and select Smart Scale Spot on the device homepage.
Step barefoot onto the scale. Wait until the digits “
” are shown
on the LED display.
- An analysis of your body’s composition will begin automatically.
After analysis, the measured data will be shown in the app.
When Measuring
Issue
Cause
• Scale is placed on
• Too high
• Place the scale on a
soft carpeting or
hard and flat surface.
• Too low
uneven surface.
• Large difference
• Wipe your feet with a
detected between two • Feet are too dry.
damp cloth, keeping
recent measurements
them slightly damp.
LED display does not
turn on after stepping
onto the scale.
Scale does not proceed
to analyse body
composition.
Step onto the center of the scale barefoot. Stand still and keep full
contact with the electrodes until the measurement is complete.
Solution
Abnormal measurement • Incorrect posture. • Step onto the scale
barefoot and stand still.
results:
• Batteries not
installed.
• Install three new
batteries.
• Worn batteries.
• Replace all three
batteries at the same
time.
• Taking a
measurement
while wearing
shoes or socks.
• Stand barefoot on the
scale and keep feet in
full contact with the
electrodes when taking
a measurement.
Specifications
Product Model
T9143
Power Source
4.5 V (3 × AAA batteries)
LED Display
3.1 × 1.3 in / 80 × 32 mm
Measurement Unitse
Pound / Stone / Kilogram
Unit Increments
0.1 lbs / 0.1 kg
Body Fat Unit Increments
0.1 %
Body Water Unit
Increments
0.1 %
Maintenance
Muscle Mass Unit
Increments
0.1 %
Regularly clean the scale with a dry or slightly dampened soft cloth.
Measurement Range
11 lbs - 410 lbs / 0 st 11 lbs - 29 st 4 lbs /
5 kg - 186 kg
Operating Environment
Temperature: 10 - 40 °C / 50 - 104 °F
Humidity: 20 - 90% RH
Storage Environment
Temperature: -10 - 50 °C / 14 - 122 °F
Humidity: ≤ 90% RH
Operating Frequency
Range
2402 - 2480 MHz
Radio-Frequency Power
5 dBm
Dimension
12 × 12 × 1 in / 300 × 300 × 25 mm
Net Weight
3.5 lbs / 1.6 kg
Measuring without the Eufylife App
This scale can also be used as a conventional weight-reading scale. You
can simply step on the scale to measure your current weight without
opening the EufyLife app.
- Do not wash the scale with water or immerse it in water.
- Never use detergents to clean the scale as this may cause
it to malfunction or discolor.
Customer Service
15-Month Limited Warranty
Lifetime Technical Support
Troubleshooting
support@eufylife.com
Error Message
Error Display
Description
+1 (800) 988 7973 (US) Mon-Fri 9:00 - 17:00 (PT)
Solution
+44 (0) 1604 936200 (UK) Mon-Fri 6:00 - 11:00 (GMT)
Weight overload. The device Stop using this scale for
will power off.
measurement.
Low battery. The device will
power off.
+49 (0) 69 9579 7960 (DE) Mon-Fri 6:00 - 11:00
Replace all three batteries
at the same time.
+81 03 4455 7823 (JP) 月-金 9:00-17:00
+ 86 400 0550 036 (中国) Mon-Fri 9:00 - 17:30
@EufyOfficial
@EufyOfficial
@EufyOfficial
@EufyOfficial
Important Safety Instructions
Read all instructions before using the device. Keep the manual for future reference.
Only use the device as described in this user manual. Any misuse may cause electric shocks, burns, start a fire or other
unexpected hazards.
This device can be used by individuals over 16 years old and persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children should not play with the appliance. Cleaning and user maintenance
should not be done by children without supervision.
Be aware that this device is designed for individuals to measure their weight and to monitor their body composition. Any
information provided by this device is in no way meant to treat, cure, or prevent diseases or illnesses from happening.
Do not use this device if you are pregnant or if you suspect you may be pregnant. The effects of this device on a fetus are
unknown and untested.
Do not use this device if you use a wearable or implanted electronic device such as a defibrillator or pacemaker.
Do not modify this device.
Do not expose this device to extreme temperatures, direct sunlight, moisture, or corrosive environments.
Do not mix and use different types of batteries together e.g. lithium-ion (Li-ion) and nickel-metal hydride (NiMH) batteries.
Do not mix new and used batteries.
This device should not be used by individuals who are acutely or chronically ill, suffering from diseases or taking
medications that can affect water levels. The accuracy of the readings for these individuals has not been verified. Specific
medical advice should be obtained from a physician.
The device is equipped with a data transmission function that emits electromagnetic energy. Portable Radio Frequency (RF)
communications equipment (including peripherals such as antenna cables and external antennas) should not be used
within 30 cm (12 inches) of the device, otherwise, performance may be affected.
To prevent slipping, do not step on the device after bathing or showering.
This device should not be used when it is adjacent to or stacked on top of another device because it could cause the device
to operate improperly. If such use is necessary, this device and the other device should be observed to verify that they are
operating normally.
This device is powered by three AAA batteries. Do not attempt to recharge non-rechargeable batteries as this can cause
the batteries to leak or explode.
This device can be powered by rechargeable batteries.
Used batteries should be placed in a sealed plastic bag and disposed of safely according to local environmental regulations.
If the device will not be used for an extended period of time, remove batteries before storing the device in a cool and dry
place.
Usage Tips:
To ensure measurement accuracy, follow the instructions below when you start your measurement:
Place the scale on a flat, hard surface. Soft surfaces such as carpeting will affect the performance of the scale.
Step on the platform with bare feet. Stand still and keep full contact with the electrodes until the measurement is complete.
For the most consistent measurements, weigh yourself at the same time of day and location.
Avoid weighing yourself immediately after strenuous exercise, sitting in the sauna, taking a bath, or drinking and eating.
The condition of the skin on the bottom of your feet can affect the measurement. The natural effects of aging or activity can
make this skin hard. Take the reading with clean, slightly damp feet for best accuracy.
Body fat percentage estimates will vary with the amount of water in the body, and can be affected by dehydration or
overhydration due to factors such as alcohol consumption, menstruation, illness, intense exercise etc.
Notice
This symbol means the product must not be discarded as household waste, and should be delivered to an
appropriate collection facility for recycling. Proper disposal and recycling helps protect natural resources,
human health and the environment. For more information on disposal and recycling of this product, contact
your local municipality, disposal service, or the shop where you bought this product.
This symbol means ”Refer to instruction manual or booklet”.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the
equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. (4) Consult the dealer or an experienced radio / TV technician for help.
RF Warning Statement
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure
conditions without restriction.
SM-A563-V01

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2017:07:28 10:40:03+08:00
Creator                         : Adobe Acrobat Pro 9.0.0
Modify Date                     : 2017:07:28 10:40:03+08:00
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2017:07:28 10:40:03+08:00
Creator Tool                    : Adobe Acrobat Pro 9.0.0
Format                          : application/pdf
Document ID                     : uuid:bd7e2844-881a-4ef3-bbaa-c90fd3529688
Instance ID                     : uuid:f1d3c2b6-fd92-45fe-ae97-ca17d071733a
Producer                        : Adobe Acrobat Pro 9.0.0
Page Count                      : 4
For                             : macPro10,
Title                           : T9143_EN_Safety_ SM-A563-V01_20170614_105x144mm.ai
Bounding Box                    : -169 -369 427 59
Container Version               : 11
Creator Version                 : 16
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AB7K-T9143

Navigation menu