Anticimex Innovation Center A S 400201 Smart Sense detects the presence of moth and cockroaches User Manual User man

Anticimex Innovation Center A/S Smart Sense detects the presence of moth and cockroaches User man

User man

Download: Anticimex Innovation Center A S 400201 Smart Sense detects the presence of moth and cockroaches User Manual User man
Mirror Download [FCC.gov]Anticimex Innovation Center A S 400201 Smart Sense detects the presence of moth and cockroaches User Manual User man
Document ID4028515
Application IDfxHuyqPx5+PRTe1SH9XLkA==
Document DescriptionUser man
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize53.29kB (666117 bits)
Date Submitted2018-10-08 00:00:00
Date Available2018-10-08 00:00:00
Creation Date2018-09-14 13:31:37
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-09-14 13:31:40
Document TitleUser man
Document CreatorAdobe InDesign CC 13.0 (Windows)

GB
Anticimex
Smart Sense
Manual
Version 2 - 13.09.2018
Substitutes version 1 - August 2018
FCC Compliance Statement Smart Sense
Smart Sense - Article number 400 201
FCC ID 2AOFP-400201
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Information to user
• The Smart Sense is only in compliance if no changes or modifications is made to the device.
• The Smart Sense is in compliance with the requirement for RF exposure in US with 20 cm
separation distance between the user and/or bystander of the device.
• The antenna is fixed to the device and no change in antenna or fixation of the antenna is
acceptable and such modification is considered to violate the Compliance Statement.
• The latest version of the manuals and datasheets are always available on
anticimexonline.sharepoint.com/sites/smartsupport
Note:
This equipment has been tested and found to comply with the limits for Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. The equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Note!
Note!
Note!
Note!
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
The instructions for appliances having a part of class III construction supplied from a detachable
power supply unit shall state that the appliance is only to be used with the power supply unit
provided with the appliance.
Smart Sense must be disconnected from its power source during repair or workshop
maintenance. Do not open / modify the internal electronic parts. For repairs, contact your
authorized Anticimex service center.
Smart Sense is for indoor use ONLY. The product is not intended for barns, stables and similar
locations. The product must NOT be used in locations where flammable vapor or explosive
dust is likely to exist.
Smart Sense is to be kept out of reach of children.
Content
Product description   4
Requirements   4
Setting up Smart Sense   4
Find Smart Sense in WisePlan   5
Information of a Smart Sense   5
Product description
Smart Sense is a two-in-one trap that can be floor mounted for cockroaches and wall mounted
for moth. It gives an early warning of infestation and activity by detecting a difference in
temperature of the insect, compared to the background which is heated.
Smart Sense is fully compatible with existing Smart Connect system.
1. Smart Sense Moth trap 		
2. Smart Sense Cockroach trap
Smart Sense is delivered as a moth trap. To convert Smart Sense into a cockroach trap
take off the black grid and the black inner skirt out and close the lid.
Requirements
The technician operating this equipment must be familiar with the Smart Connect family, since
Smart Sense is required to be linked to a Smart Connect to function. For basic instruction of
the Smart Connect system, see “Smart Connect Manual”.
Smart Sense is equipped with a power supply with a 2m (6,6ft) cable. Make sure to have
available power sockets at the client, and bring extension cords if needed.
Smart Sense is for indoor use only.
Note: A Smart Connect can have a maximum of 50 linked devices. Five of those can be Smart
Box Link, the rest must be Smart Eye, Smart Catch or Smart Sense.
Setting up Smart Sense
Make sure to have a Smart Connect in Link mode, before linking the Smart Sense.
Insert the glue board and use the proper pheromone according to the application of the
specific Smart Sense. Information about glue board size and pheromone types are mentioned
in the Smart Sense data sheet.
When the Smart Connect is in link mode, apply power to the Smart Sense by plugging it into an
available power socket. Press the
button of the Smart Sense to make it start linking to the
installation. A steady green light indicates a successful link.
After linking the Smart Sense, use the “setup” function from the device list of WisePlan, to
choose whether the Smart Sense is used to detect crawling or flying insects. The Smart Sense
automatically uses the proper PIR-setting.
Find a Smart Sense in WisePlan
Since Smart Sense is not an independent unit, but linked to a Smart Connect, you have two
options for searching out the trap:
a.
b.
Use the “Find Smart Connect” option, and type in the serial number of the Smart Sense.
Use the search field, but search out the Smart Connect it is linked to.
Information of a Smart Sense
The information of the Smart Sense is now visible in the device list of a Smart Connect. To
change the list setup, simply use “List setup” menu in the device list.
The activity of the Smart Sense is displayed in the “PIR count” column. Activity will result in
the icon:
and an alarm. The icon will show in the device list until the device has been
started again by a technician.
All activity in this period will still be registered.
Anticimex Innovation Center
+45 48 79 93 78
AIC@anticimex.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Language                        : da-DK
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36
Create Date                     : 2018:09:14 13:31:37+02:00
Metadata Date                   : 2018:09:14 13:31:40+02:00
Modify Date                     : 2018:09:14 13:31:40+02:00
Creator Tool                    : Adobe InDesign CC 13.0 (Windows)
Instance ID                     : uuid:06c1b070-38b0-4c5b-88ce-e95f76baca08
Original Document ID            : xmp.did:327eecbb-21fd-3443-9066-5e3640df9d65
Document ID                     : xmp.id:1c97a1c1-ce1a-ad44-82fd-618f577ad718
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:d7507f99-ee64-c147-8884-8837f3c10fc9
Derived From Document ID        : xmp.did:a2039c40-4d97-f54e-8646-4f9494b7ba60
Derived From Original Document ID: xmp.did:327eecbb-21fd-3443-9066-5e3640df9d65
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.0 (Windows)
History Changed                 : /
History When                    : 2018:09:14 13:31:37+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CC 13.0 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AOFP-400201

Navigation menu