Apc 66124 Users Manual
66124 to the manual b9a98d0f-c9fd-4b98-b021-05d4505ada57
2015-02-03
: Apc Apc-66124-Users-Manual-470934 apc-66124-users-manual-470934 apc pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Network Management Teleservice Card (66124) ETH ERN PHON E ET SENS OR/R S 485 Installation manual ACT RESE T 100M ( Sett ings ) 6612 4 3402231500/AC CD 990-3402231500AC UPS D ata INTRODUCTION OVERVIEW 000623001C07 000623001C07 The Network Management Teleservice Card (66124) is recommended for central UPSs protecting entire networks or for UPS units backing up critical loads. With the card installed, the UPS has its own IP address and uses the local computer capabilities to: ◗ supply web pages (http or https (SSL)) with information on status conditions and measurements/settings/alarms, ◗ integrate an SNMP-based NMS such as HP OpenView, IBM Tivoli Netview and Computer Associates Unicenter, ◗ communicate with shutdown modules installed on the protected servers (Network Shutdown Module), ◗ send e-mail and SMS messages, ◗ control the ON/OFF function of the UPS and the outlets, ◗ monitor the Environment Sensor, ◗ Access the Teleservice solution for remote monitoring and maintenance services of your UPS. MAC adress PHONE port: Green LED : Phone communication with the UPS Orange LED : Modem connection ETHERNET port: Green LED : Connection + activity UPS Da ta CD Orange LED : 10/100 M ETH ERN PHON E ET SENS OR/R S 485 ACT RESE T Service port (Sensor/RS485): 100M ( Set tings) 6612 4 Green LED : Communication with the UPS The Network Management Teleservice Card must be installed and used in accordance with manufacturer instructions. Orange LED :RS232 activity Catalogue number UNPACKING AND CHECKS ◗ ◗ ◗ ◗ ◗ INDICATIONS One Network Management Teleservice Card (66124), One serial cable for configuration (3402226700), One phone cable for teleservice (3402226800), One installation manual (34022315EN), One Teleservice information form (3402228500), PHONE port LED UPS Data Colour Green Status Description ◗ OFF ◗ Card not connected to phone ◗ ON ◗ Card connected to phone ◗ Flashing ◗ Port is sending/receiving ◗ OFF ◗ ON ◗ Flashing ◗ Modem is not connected ◗ Modem is connected ◗ Modem is connecting network network, but no activity CD Settin gs/Se nsor ETHE RNET Setting s/Sens or Orange Settin gs/Se nsor Settings /Sensor Settings /Sensor 100M UPS 10M data ETHERNET port RS2 32 6610 8 LED ACT Colour Green Network Management Teleservice Card (66124) Settin gs/Senso r Settin gs/Se nsor ETH Settings/Sen sor 100M ERN ET Settin gs/Senso r UPS data Description ◗ Card not connected to network ◗ Card connected to network, but ◗ Flashing ◗ Port is sending/receiving ◗ OFF ◗ ON ◗ Port operating at 10 Mbits/s ◗ Port operating at 100 Mbits/s no activity Installation manual Settings/Sen sor 10M Status ◗ OFF ◗ ON RS232 66124 100M Orange Service port (Sensor/RS485) LED Colour Status Description Sensor Green ◗ OFF ◗ ON ◗ Flashing ◗ Card starting ◗ Card ready ◗ Communication with environment RS485 Orange ◗ OFF ◗ Flashing ◗ Flashing ◗ Settings mode activated ◗ Port is sending/receiving ◗ Communication fault or every seconds configuration errors Sensor is operational SWITCHES SETTING Default settings, sensor configuration : SA1 SA2 1 3 3 ON ON OFF OFF 8 8 3402231500/AC 1 INSTALLATION Your network is not equipped with a BOOTP/DHCP server The Network Management Teleservice Card (66124) can be hotplugged on MGETM GalaxyTM 7000 UPSs. It is not necessary to shutdown the UPS, disconnect the load or restart the UPS. ◗ A. Remove the plastic cover of the Minislot. ◗ B. Note the MAC address of the card before inserting it. ◗ C. Connect the PHONE cable. ◗ D. Connect the ETHERNET cable (network already connected). ◗ E. Insert and secure the card with the screws. E A UPS Data CD ETHE RNE UPS T SENS OR/RS 485 PHONE ACT 100M 000623001C07 000623001C07 RESET ( Settings) 66124 C D B ◗ Check the ETHERNET port indications. ◗ Wait until the UPS Data LED flashes regularly (approx. two minutes), indicating that card start-up has terminated correctly. Once the card has started, proceed as indicated below. ◗ Connect one end of the serial cable to the Service port. ◗ Connect the other end of the cable to the COM (IOIOI) port of a PC. ◗ Run a terminal emulator such as HyperTerminalTM with these settings Data bits 8 Stop bits 1 1 : Read Network settings 2 : Modify Network settings 3 : Set ethernet speed 0 : Exit For each of the following questions, you can press "Return" to select the value shown in braces, or you can enter a new value Should this target obtain IP settings from the network?[N] N Static IP address [172.17.16.16]?172.16.1.82 Subnet mask IP address [255.255.0.0]? 255.255.255.0 Gateway address IP address [0.0.0.0]? 172.17.17.1 Done Wait until "Done" is displayed, indicating that the IP parameters have been saved. ◗ Press the 0 key (Exit), then press the ↵ key. ◗ Press the 1 key (Reset), then press the ↵ key. The card restarts with the new IP settings (after approx. two minutes). ACCESS TO SUPERVISION IP SETTINGS Bits per second 38400 Manual configuration is required. To set the network configuration(from the main configuration menu): ◗ Press the 2 key (Network configuration), then press the ↵ key. ◗ Press the 2 key (Modify Network settings), then press the ↵ key. ◗ Follow the instructions and enter the IP parameters: Flow control none To check whether the Network Management Teleservice Card is operational after installation and IP settings, proceed as follows. ◗ Run a browser ◗ Enter in the address bar: http://IP address/ (e.g. http://172.16.1.82/) ◗ The home page is displayed: "Echo typed characters locally" option: disabled ◗ Press the ↵ key. ◗ press the 1 key (Network configuration menu) ◗ Type MGEUPS (or mgeups), then press the ↵ key. The main configuration menu is displayed : APC by Schneider Electric NETWORK MANAGEMENT CARD 1 : Reset 2 : Network configuration 3 : Set Login Password to Default 4 : Return to Default Configuration 0 : Exit Your network is equipped with a BOOTP/DHCP server (default) The card is configured by default with this service enabled. No manual configuration is required.The IP parameters are automatically collected by the card. To view the network configuration(from the main configuration menu): ◗ Press the 2 key (Network configuration), then press the ↵ key. ◗ Press the 1 key(Read Network settings)., then press the ↵ key. The settings supplied by the server are displayed: Network configuration : MAC address : 00:06:23:00:1C:07 Mode : DHCP IP address : 172.17.23.18 Subnet mask : 255.255.248.0 Gateway : 172.17.17 ◗ ◗ ◗ ◗ Note the IP address. Press the ↵ key Press the 0 key (Exit), then press the ↵ key. Press the 0 key (Exit), then press the ↵ key. ◗ Set the time by clicking the Time command. ◗ Continue configuration via the sections in the Settings menu. Teleservice procedure ◗ Install the Network Management Teleservice Card kit using the present manual. ◗ Fill in the information form (3402228500). ◗ Send the form to your Teleservice centre (by Fax or Internet). ◗ Your centre will activate this service. ◗ You receive an acknowledgement of receipt. The information form must be sent back in order to trigger remote monitoring of your equipment. USER MANUAL The manual (34003991EN) provides all the information required to use, install and configure the Network Management Teleservice Card. For more information on the supervision, control and configuration functions offered by the Network Management Teleservice Card, see the user manual on the www.apc.com web site. 3402231500/AC SENSOR CONNECTION (option) The Environment sensor is a Network Management Teleservice Card option. The sensor remotely monitors the UPS environment by regularly measuring the temperature and humidity, and checking the states of two external contacts. It can also send alarms (e-mail, SNMP trap) tripped by pre-set thresholds. Connection is made via the Service port (Settings/Sensor) on the Network Management Teleservice Card. The sensor is detected automatically. Configuration and supervision use a menu that may be accessed directly from the home page. For more information, see the user manual of the Network Teleservice Management Card. TECHNICAL CHARACTERISTICS Physical characteristics Dimensions (W x D x H) 132 x 66 x 42 mm Weight 85 g RoHS 100% compatible Storage Storage temperature range -10°C to 70°C Ambient conditions Operating temperature range 0°C to 40°C Relative humidity 90% RH max. without condensation Card performance Setings /Senso r ETHE RNETSe UPS data RS2 32 PHONE tting s/Sen sor Setings /Senso r 100M On = Blin Link k = Act 10M UPS data RS2 ETHE RNETSe 32 6610 tting 2 s/Sen sor Supply voltage 5V ±5% Supply current (all LEDs ON and Environment Sensor connected) 500 mA max. 100M 10M Functions ETHERNET UPS Web supervision 5 browsers max. (http), 3 browsers max. (https) Languages English Alarms E-mail, SNMP TRAP, Web page Log 400 measurements or events Server protection Up to 35 servers protected Network Fast ETHERNET, 10/100 Mbits, auto-negotiation HTTP 1.1, SNMP V1, NTP, TFTP, SMTP, BOOTP/DHCP Identification User name and password Security SSL 3.0, TLS 1.0 Browsers Microsoft Internet Explorer 6.x or higher NMS Enterprise Power Manager (EPM) Management-Pac 2 MIB MIB II standard - MGE V1.7 MIB Settings (default values) IP network BOOTP/DHCP enabled IP address: 172.17.16.16 Subnet mask: 255.255.0.0 Gateway: 0.0.0.0 NTP server: pool.ntp.org Web-page access control User name: MGEUPS Password: MGEUPS Service-port menu access control Password: MGEUPS or mgeups (not modifiable) Date and time Synchronise with an NTP server (GMT) Service port 38400 bits/s, 8 bits, 1 bit stop, no parity Standards ITE (Information Technology Equipment) safety 3402231500/AC IEC/EN 60950-1 (2005) R&TTE 99/05/EEC EMC EN 61000-6-2 (2005), EN 61000-6-3 (2006) 2004/108/EEC Low voltage 2006/95/EEC FCC (Federal Communication Commission ) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 4 Page Mode : UseNone XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:f4e7e069-f537-4a3d-ad2c-8ad1cb827828 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2006:03:17 09:25:22Z Creator Tool : FrameMaker 7.0 Modify Date : 2009:05:13 14:09:51Z Document ID : uuid:56cfd03f-af93-4c71-8513-fd402f62f729 Format : application/pdf Title : untitled Creator : FrameMaker 7.0EXIF Metadata provided by EXIF.tools