Apc Galaxy 6000 Users Manual 01NT389E
6000 to the manual 82fabaae-e8c4-4e2a-a72d-08c3846c317f
2015-02-03
: Apc Apc-Galaxy-6000-Users-Manual-470974 apc-galaxy-6000-users-manual-470974 apc pdf
Open the PDF directly: View PDF .
Page Count: 38
Download | |
Open PDF In Browser | View PDF |
MGETM GalaxyTM 6000 50, 60 Hz 250 - 600 kVA "GTC link" communication interface User manual 125 0 Hour kVA120% 100% 50 Min. 100% 80% 50% 6000 AXY GAL E IQ SALL 400 kVA 50% 0 Load protect ed Availab le Backup Load 0 level Time Q5N Load ent equipm Home Alarms Q1 QF1 Online Trend Statisti cs Rectifie Norma l AC r Q4S Battery Inverte r Bypass 15:24:3 AC 2 30/05/2 005 Q3BP Bypass Output Set up 6739389EN/FB - Page 1 Page 2 - 6739389EN/FB Contents Presentation ...................................................................................................... 4 Introduction ................................................................................................................ 4 "GTCZ" and "GT2Z" boards features ......................................................................... 4 Communication settings ........................................................................... 5 JBUS protocol .................................................................................................. 6 Introduction ................................................................................................................ 6 Principle ..................................................................................................................... 7 Synchronizing data exchanges .................................................................................. 7 Description of request and response frames ............................................................. 7 Checking received messages on the slave-side ........................................................ 8 Functions .................................................................................................................... 9 CRC 16 algorithm .................................................................................................... 14 UPS theory of operation .......................................................................... 18 Unitary UPS ............................................................................................................. 18 Parallel connected UPS with "Static Switch" cubicle ............................................... 19 UPS without Mains 2 ................................................................................................ 19 Unitary UPS ..................................................................................................... 21 Block diagram .......................................................................................................... 21 Measured quantities ................................................................................................. 21 Main status bits ........................................................................................................ 22 Operating modes ..................................................................................................... 22 Parallel connected UPS ........................................................................... 24 Block diagram .......................................................................................................... 24 Measured quantities ................................................................................................. 24 Main status bits of system operations ...................................................................... 25 Operating modes ..................................................................................................... 25 Static switch cubicle .................................................................................. 26 Block diagram .......................................................................................................... 26 Measured quantities ................................................................................................. 26 Main status bits of system operations ...................................................................... 27 Operating modes ..................................................................................................... 27 System information .................................................................................... 28 Message format ....................................................................................................... 28 Example of read data ............................................................................................... 28 Sample commands .................................................................................................. 28 List of variable fields ................................................................................................ 28 General definitions ................................................................................................... 29 Signaling field ........................................................................................................... 29 Tables measured data .............................................................................................. 29 Tables of binary data ................................................................................................ 31 Table of control devices ........................................................................................... 33 Telemonitoring information ....................................................................................... 33 Glossary of information descriptors ......................................................................... 34 Glossary of telemonitoring information descriptors .................................................. 37 All MGETM GalaxyTM 6000 products are protected by patents. They implement original APC by Schneider Electric technology not available to other manufacturers. This document may be copied only with the written consent of APC by Schneider Electric. Authorized copies must be marked "APC by Schneider Electric GTC link communication interface user manual No. 6739389EN". 6739389EN/FB - Page 3 Presentation Introduction The "GTC link" communication interface is designed to transmit MGETM GalaxyTM 6000 UPS operating information and remote "on/off" commands (if available) to an external computer. The JBUS hexadecimal communication protocol is used (the JBUS ASCII mode is not used in this application). The "GTC link" features two symmetrical communication channels, both with a simplified V24 (RXD and TXD only) and an RS485 interface. It consists of a "GTCZ" communication board (central unit) and a "RAUZ 1" (communication network management and interconnection board). In option, two additional communication ports can be added: "GT2Z" board (central unit) and "RAUZ 2" board (communication network management and interconnection board). Refer to the "communication options connection manual" of MGETM GalaxyTM 6000 nr 6739388XU, for all informations about connections. Page 4 - 6739389EN/FB "GTCZ" and "GT2Z" boards features The "GTCZ" and "GT2Z" boards are functionally divided into two main modules: The ACQ module The COM module performs data acquisition; monitors the status bus of the monitor/control boards; ◗ computes physical quantities and battery backup time; ◗ processes alarms; ◗ sends commands to monitor/ control boards; ◗ stores configurable parameters and communicates with the "Soft Tunor" software, used by APC by Schneider Electric after-sales service; ◗ transfers data using the on-board communication channels. The COM communication module is designed for external devices (e.g. "AMUZ" type board of a "Monitor" or "Tele-Monitor") to: ◗ retrieve information and parameters processed by the ACQ; ◗ send commands to monitor/ control boards; ◗ be integrated into other systems (remote indications and supervision). ◗ ◗ Each "GTCZ" or "GT2Z" board is equipped with two symmetrical communication ports, COM1 and COM2: ◗ on the "GTCZ" board: ◗ COM1 for a "display devices" network consisting of "AMUZ" boards in a unitary or parallel connected UPS configurations, ◗ COM2 for a supervisory system; ◗ on the "GT2Z" board: ◗ COM1 and COM2 for a supervisory system. The "GTCZ" and "GT2Z" boards are configured with the APC by Schneider Electric after-sales customization software called "Soft Tunor". The computer link is via the test connector located on the front panel of the cubicles and performs: ◗ configuration, calibration and control of the ACQ module; ◗ configuration of COM1 and COM2 ports. Communication settings The COM1 and COM2 communication ports can be configured as follows: ◗ data rate: 1200, 2400, 4800, 9600 Baud; ◗ data bits: 8 (always); ◗ parity: none, odd, even; ◗ stop bits: 1 or 2; ◗ slave address: 20H to F8H in increments of 8H; ◗ interface: ◗ 0 = RS232 simplified, ◗ 1 = RS232 complete (not implemented), ◗ 2 = RS485; command masks; other parameters (modem type, telephone number, handshaking, modem protocol, password) reserved for later use. ◗ ◗ Location of the "GTCZ" and "GT2Z" boards in the cubicle electronics Acquisition Status CRIZ (only in rectifier-inverter cubicle) CROZ (only in rectifier-inverter cubicle) AROZ (in all cubicles) Test channel Acquisition INTERNAL BUS Status Test channel Acquisition Status Test channel Test channel SRIZ Status Acquisition COM1 Status Test channel GTCZ RAUZ 1 COM2 Commands Soft Tunor Acquisition COM1 Status Test channel GT2Z RAUZ 2 COM2 Commands 6739389EN/FB - Page 5 JBUS protocol Introduction JBUS protocol can be used to read or write one or more bits or words. In the interest of simplicity, this document describes only the procedures necessary for operation and monitoring of the APC by Schneider Electric unit. Master request response Slave Slave Slave Communications are initiated by the master and include a request from the master and a response from the slave. Master requests must be addressed to one specific slave (identified by its address in the first byte of the request frame) as shown in the diagram opposite: Response analysis and preparation of next exchange Wait Wait MASTER request request to slave 1 to slave N SLAVE 1 response request processing SLAVE N response PHYSICAL MEDIA Exchange i Page 6 - 6739389EN/FB Exchange i+1 JBUS protocol (continued) Principle A full understanding of the protocol is only required if the master is a computer that must be programmed. All communications include 2 messages: a request from the master and a response from the slave. Each message or frame containes 4 types of information: ◗ slave address (1 byte) The slave address specifies the destination station (see address list): ◗ unitary rectifier-inverter cubicle, ◗ parallel rectifier-inverter cubicle, ◗ Static Switch cubicle. If zero, the request addresses all slaves and there is no response message (in which case it is a broadcast message, a function not used in this application); ◗ function code (1 byte) Selects a command (e.g. read or write a bit or a word) and checks that the response is correct. The JBUS protocol comprises 10 functions of which 3 may be used in this application: function 3 (read n output or internal words), or function 4 (read n input words), or function 16 (write n words); ◗ information field (n bytes) The information field contains the parameters related to the functions: bit address, word address, bit value, word value, number of bits, number of words; ◗ check word (2 bytes) A word used to detect transmission errors. Synchronizing data exchanges Any character received after 3 or more character lengths of silence is interpreted as the start of a frame. Therefore, a minimum silence of 3 character lengths between frames must be respected. Description of request and response frames request 1 byte slave adress (1 à FF) 1 byte function code information requested: bit/word address, bit/word value, bit/word number. 2 bytes check word information n bytes This function code selects one of 10 possible commands: - Function 1 : read n output or internal bits - Function 2 : read n input bits - Function 3 : read n output or internal words - Function 4 : read n input words - Function 5 : write one bit - Function 6 : write one word - Function 8 : data exchange diagnostics - Function 11 : read event counter - Function 15 : write n bits - Function 16 : write n words values of bits or words read values of bits or words written number of bits or words response slave adress (1 à FF) 1 byte When the message is received, the slave reads the check word and accepts or refuses the message function code data 1 byte ◗ bytes CRC check word 2 bytes 6739389EN/FB - Page 7 JBUS protocol (continued) Checking received messages on the slave side After the master sends a request containing the slave address, the function code and data, it computes the CRC and sends it as the check word (CRC 16). When the slave receives the request, it stores the message in memory and calculates the CRC 16 to compare it to the received CRC 16. If the message is incorrect (unequal CRC 16 values), the slave does not respond. If the message received is correct but the slave is unable to process it (incorrect address, incorrect data, etc.), the slave returns an error message with the following contents (see opposite): slave master slave address CRC 16 computation function data CRC 16 CRC 16 comparison Error codes: 1. Unknown function code 2. Incorrect address 3. Incorrect data 4. Station not ready 8. Write error 9. Field overlap response function code received and MS bit = 1 slave address (1 à FF) 1 CRC 16 1 byte 1 byte 1 byte example Page 8 - 6739389EN/FB errors handled by the communication port 01 09 H 00 01 89 H 01 00 00 86 50 00 DD CB request response 2 bytes JBUS protocol (continued) Functions Function 1 and 2: read N bits function 1: read output or internal bits; ◗ function 4: read input bits. The number of bits must be less than or equal to the bit field size (see memory board). ◗ request slave address address of first bit MSB LSB 1 or 2 1 byte 1 byte number of bits to read 2 bytes CRC 16 2 bytes 2 bytes response slave address number of bytes read 1 or 2 1 byte 1 byte first byte read 1 byte last byte read CRC 16 ✷ bytes 2 bytes byte detail: last bit transmitted first bit transmitted Unused bits are set to zero example Reading bits at location 404 to 411 of slave at address 20H (charger signals) request: 20 01 0404 0E 66 FE response: 20 01 02 10101001 40B 00101110 404 411 FB B7 40C (binary values) 6739389EN/FB - Page 9 JBUS protocol (continued) Function 3 and 4: read N words The number of words must be less than or equal to the word field size (see memory board). ◗ function 3: read output or internal words; ◗ function 4: read input words. request slave address 3 or 4 1 byte adress of first bit MSB LSB number of words MSB LSB 2 bytes 2 bytes 1 byte CRC 16 2 bytes response slave address number of bytes read 3 or 4 1 byte 1 byte 1 byte first word last word PF PF pf 2 bytes 2 bytes CRC 16 pf 2 bytes example Reading words at location 146 to 14B of slave at address 28H (voltage fields) request: 28 03 0146 06 A7 E0 response: 28 03 0C XXXX YYYY word 0146 word 014B CRC 16 Function 5: writing a bit request slave address 1 byte 5 bit address 2 bytes 1 byte bit value 0 1 byte bit set to 0 bit set to 1 1 byte CRC 16 2 bytes write 0 write FF response slave address 5 bit address bit value In function 5 the response and request frames are identical. example Setting bit location C05 to 1 of slave at address 40H (inverter on) request: 40 Page 10 - 6739389EN/FB 05 0C05 FF 00 90 7A 0 CRC 16 JBUS protocol (continued) Function 6: writing a word request slave address 6 word address word CRC 16 1 byte 1 byte 2 bytes 2 bytes 2 bytes 6 word address word CRC 16 response slave address The response is echoed acknowledging that the word sent has been received. example Writing the value 1000 into the word location 810H of slave at address 50H 50 06 08 10 10 00 8A 2E Function 8: reading error diagnosis counters Each slave manages a set of nine 16 bit counters for error diagnosis (see opposite): - request / response: slave address 1 byte 8 sub-function code 1 byte data 2 bytes 2 bytes - the slave must echo the request 00 XYZT - reset error diagnosis counter 0A 0000 0B XXXX CRC 16 2 bytes X, Y, Z, T are user defined (transmission parameters) - read the total number of: received frames with CRC error (CNT 1) received frames with CRC error (CNT 2) 0C XXXX number of exception responses (CNT 3) 0D XXXX frames addressed to the station (CNT 4) (not including broadcast) broadcast requests received (CNT 5) 0E XXXX 0F XXXX number of NACK responses (CNT 6) unit not ready responses (CNT 7) 10 11 XXXX XXXX illegal characters (CNT 8) 12 XXXX requests: XXXX equals 0000 response: XXXX is the counter value 6739389EN/FB - Page 11 JBUS protocol (continued) Function 11: reading event counters The master and each slave have one event counter. This counter is incremented each time a frame is received and interpreted correctly by the slave (except for function 11 itself). A correctly transmitted message increments the counter. If the slave sends an exception response, the counter is not incremented. request slave address response slave address The master can read the counter to determine whether or not the slave correctly interpreted the command (incremented the counter or not). These functions can be used to diagnose the data exchange taking place between master and slaves. CRC 16 0B 1 byte 1 byte 0 slave counter word CRC 16 2 bytes 2 bytes 2 bytes 0B If the master counter equals the slave counter, the slave executed the command sent by the master. If the master counter is one higher than the slave counter, the slave did not execute the command sent by the master. Function 15: writing n consecutive bits request slave adress 1 byte address of the first bit 0F 1 byte 2 bytes number of bits number of bytes bit data CRC 16 2 bytes 1 byte n bytes 2 bytes 2 X 1968 réponse 1 N 246 first bit of first byte last bit of first byte first bit of byte N last bit of byte N first byte N bytes response slave address 1 byte 0F 1 byte address of the first bit number of bits CRC 16 2 bytes 2 bytes 1 X 1968 2 bytes Note: if the slave address is 0, all units execute the write command without sending a response. Page 12 - 6739389EN/FB JBUS protocol (continued) Function 16: writing n consecutive words request slave address 1 byte 10 (*) address of first word 1 byte 2 bytes number of words number of bytes N data bytes 1 byte n bytes 2 bytes CRC 16 2 bytes 2 X 123 4 N 246 MSB LSB MSB LSB MSB MSB LSB last word first word response slave address 1 byte 10 (*) 1 byte address of first word number of words written CRC 16 2 bytes 2 bytes 2 bytes Note: if the slave address is 0, all units execute the write command without sending a response example Writing words 00 and 01 of slave at address 20 (synchronization counter) (00) = 0000 (01) = 0000 request 20 10 (*) 0000 0002 04 0000 0000 0000 0000 5C 93 response 20 ) * 10 (*) 0000 0002 47 79 ( 6739389EN/FB - Page 13 JBUS protocol (continued) CRC 16 algorithm If the CRC 16 is calculated using the above algorithm, the least significant byte is transmitted first. Hex FFFF --> CRC 16 CRC 16 BYTE --> CRC 16 n=0 CRC 16 shift to the right no remainder yes CRC 16 poly --> CRC 16 n = n+1 no yes n>7 no following byte end of message yes END n poly Page 14 - 6739389EN/FB = = = exclusive or number of data bits CRC 16 polynomial = 215 + 213 + 20 = $ A001 JBUS protocol (continued) Example of CRC computation CRC register initialization of 1st character Set flag to 1, Set flag to 1, Shift 1 1111 1111 1111 0000 1111 0010 Shift 1 1111 0111 1010 1111 1111 0000 1111 1111 0000 1101 1110 0001 1 Shift 2 1101 0110 1010 1111 1111 1111 1111 1111 1111 0001 1 Shift 3 Shift 4 1100 0110 0011 101 1111 0111 0011 1111 1111 1111 1110 1111 1111 1 0 1 Shift 5 Shift 6 1001 0100 0010 101 0011 1001 0100 1111 1111 1111 1110 1111 1111 1 0 1 Shift 7 Shift 8 1000 0100 0010 101 0100 0010 0001 1111 0111 0011 1110 1111 1111 1 0 1 1000 0001 0011 0000 1110 0111 Shift 1 1000 0100 101 0001 0000 0011 1001 1001 1101 1 1 Shift 2 1110 0111 101 0000 0000 1001 0100 1101 1110 1 1 Shift 3 1101 0110 101 0000 1000 0100 0010 1111 0111 1 1 Shift 4 Shift 5 1100 0110 0011 101 1000 0100 0010 0010 0001 0000 0110 0011 1001 1 0 1 Shift 6 Shift 7 Shift 8 1001 0100 0010 0001 0010 1001 0100 0010 0000 0000 1000 0100 1000 0100 0010 0001 0 0 0 polynomial polynomial Set flag to 0 2nd character byte byte 6739389EN/FB - Page 15 JBUS protocol (continued) Example of CRC 16 computation in "C" using table lookup #define CPH 0 /* most significant bytes */ #define CPL 1 /* least significant bytes */ /* TABLE OF MOST SIGNIFICANT BYTES FOR CRC16 COMPUTATION */ char tbcrch [ ] = { 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 1,192,128,65,0,193,129,64,0,193,129,64,1,192,128,65, 0,193,129,64,1,192,128,65,1,192,128,65,0,193,129,64, }; /* TABLE OF LEAST SIGNIFICANT BYTES FOR CRC16 COMPUTATION */ char tbcrcl [ ] = { 0,192,193,1,195,3,2,194,198,6,7,199,5,197,196,4, 204,12,13,205,15,207,206,14,10,202,203,11,201,9,8,200, 216,24,25,217,27,219,218,26,30,222,223,31,221,29,28,220, 20,212,213,21,215,23,22,214,210,18,19,211,17,209,208,16, 240,48,49,241,51,243,242,50,54,246,247,55,245,53,52,244, 60,252,253,61,255,63,62,254,250,58,59,251,57,249,248,56, 40,232,233,41,235,43,42,234,238,46,47,239,45,237,236,44, 228,36,37,229,39,231,230,38,34,226,227,35,225,33,32,224, 160,96,97,161,99,163,162,98,102,166,167,103,165,101,100,164, 108,172,173,109,175,111,110,174,170,106,107,171,105,169,168,104, 120,184,185,121,187,123,122,186,190,126,127,191,125,189,188,124, 180,116,117,181,119,183,182,118,114,178,179,115,177,113,112,176, 80,144,145,81,147,83,82,146,150,86,87,151,85,149,148,84, 156,92,93,157,95,159,158,94,90,154,155,91,153,89,88,152, 136,72,73,137,75,139,138,74,78,142,143,79,141,77,76,140, 68,132,133,69,135,71,70,134,130,66,67,131,65,129,128,64, }; Page 16 - 6739389EN/FB JBUS protocol (continued) */ **************************************************************************************************** */ /* FUNCTION CALL: crc = crc16 (message, length); */ /* with char *message; message = address of message */ /* */ /* int length; length of received message (including CRC) */ /* expressed in number of bytes */ /* int crc; = CRC16 calculated from the "address", "code" and */ /* "information" fields. */ /* */ /* RETURN VALUE: calculated crc 16 (int crc) */ /***************************************************************************************************** */ int crc16 (message, length) unsigned char message [ ]; int length; { int i ; int j ; union { int ival ; unsigned char cval [ 2 ]; /* /* /* /* /* /* /* /* /* /* /* /* /* buffer containing message for which the crc16 is to be calculated. length of message to be checked (including crc16) beginning of the function loop variable calculation and displacement variable calculated crc16: - whole - table of 2 characters unsigned is important since otherwise the sign extension causes negative displacements with respect to the beginning of the table */ */ */ */ */ */ */ */ */ */ */ */ */ } crcal; /*$ initialization of calculated crc */ /*$ correction of the length to be checked: remove the /*$ received crc16 from the length to be checked */ */ /*$ WHILE there are bytes to be checked DO */ crcal.ival = 0XFFFF; i = 0; length = length - 2; while ( i < length ) { /*$ calculate the table index j = (int) ( message [ i ] ^ crcal.cval [ CPH ] ); /*$ most significant byte crcal.cval [ CPH ] = tbcrch [ j ] ^ crcal.cval [ CPL ]; /*$ least significant byte crcal.cval [ CPL ] = tbcrcl [ j ]; /*$ next byte i++; }; /*$ END WHILE there are bytes to be checked /*$ return the calculated crc return ( crcal.ival ); } /* end of function */ */ */ */ */ */ */ Note: if the CRC16 is computed using table lookup, the most significant byte is transmitted first. 6739389EN/FB - Page 17 UPS theory of operation Unitary UPS The unitary MGETM GalaxyTM 6000 UPSs are made up of five modular sub-assemblies: ◗ ◗ ◗ ◗ ◗ rectifier-charger; battery; three-phase inverter; static switch; maintenance bypass. The load and Mains 2 operate at 50 or 60 Hz. Mains 1 power up the inverter receives power from the rectifier-charger and supplies power to the load. There is no direct connection between Mains and load; ◗ the battery is charged or the charge maintained. static by-pass switch ◗ Mains 2 rectifiercharger inverter Mains 1 load battery Mains 1 power down the inverter receives power from the battery and supplies power to the load; ◗ the battery discharges. static by-pass switch ◗ Mains 2 rectifiercharger inverter Mains 1 load battery Major overload Mains 2 supplies power to the load via the static switch; ◗ the inverter is shut down; ◗ the inverter starts-up automatically as soon as overload is removed; ◗ power is transferred without affecting the load. static by-pass switch ◗ Mains 2 rectifiercharger inverter Mains 1 load battery Maintenance Mains 2 supplies power to the load via the maintenance bypass; ◗ the rectifier-charger and inverter are shut down and disconnected from all sources of power. Q3BP ◗ static by-pass switch Q4S Mains 2 rectifiercharger inverter Q1 Q5N load Mains 1 QF1 battery Page 18 - 6739389EN/FB UPS theory of operation (continued) Parallel connected UPS with "Static Switch" cubicle Up to six parallel connected rectifier-inverter cubicles can be combined with one "Static Switch" cubicle to form a system that operates like a unitary UPS system. Each parallel connected rectifierinverter cubicle houses a: ◗ rectifier-charger; ◗ battery; ◗ three-phase inverter. The "Static Switch" cubicle contains: ◗ static by-pass switch; ◗ maintenance bypass. The units have separate batteries: static by-pass switch Mains 2 rectifiercharger inverter Mains 1 battery rectifiercharger inverter Mains 1 load battery UPS without Mains 2 All UPSs without Mains 2 contain the same sub-assemblies: ◗ rectifier-charger; ◗ battery (option); ◗ three-phase inverter. They may or may not be parallel connected depending on type and may or may not contain a battery. The output voltage has a frequency of 50 or 60 Hz. Operation without battery Mains 1 power up: ◗ the inverter receives power from the rectifier-charger and supplies power to the load. There is no direct connection between Mains 1 and the load. rectifiercharger inverter Mains 1 load Mains 1 power down: ◗ no power to the load. rectifiercharger inverter Mains 1 Maintenance position (disconnected): ◗ no power to the load (except in parallel connected systems, where other units supply power). load rectifiercharger Q1 Mains 1 inverter Q5N load 6739389EN/FB - Page 19 UPS theory of operation (continued) Operation with battery Mains 1 power up: ◗ the inverter receives power from the rectifier-charger and supplies power to the load. There is no direct connection between Mains 1 and the load. Mains 1 power down: ◗ the inverter runs on battery power and supplies power to the load; ◗ the battery discharges. Maintenance position rectifiercharger inverter Mains 1 load battery rectifiercharger inverter Mains 1 load battery (disconnected): ◗ no power to the load (except in parallel connected systems, where other units supply power). rectifiercharger inverter Q1 Q5N load Mains 1 QF1 battery Page 20 - 6739389EN/FB Unitary UPS This chapter presents the specific operating aspects and system data provided by the "GTCZ" and "GT2Z" boards in unitary UPSs. For more detailed information, please refer to the "system information" section. Block diagram Q3BP Q4S static by-pass switch a Mains 2 rectifiercharger inverter Q1 Q5N K3N Mains 1 load b e c d QF1 battery Measured quantities a F Mains 2 <1A2> U Mains 2 I Mains 2 <149 to 14E> <109 to 10B> b F Mains 1 <1A0> U Mains 1 I Mains 1 <140 to 142> <100 to 102> F inverter <1A1> U inverter I inverter <143 to 148> <106 to 108> F load <1A3> U load I load <14F to 154> <10C to 10E> U battery or U dc Battery temperature <155 or 1C0> <1C3> c d Apparent and active power <180 to 187> e I battery or I dc <115 or 1C1> Battery backup time <1C2> The numbers enclosed by <> are the addresses in the data array. 6739389EN/FB - Page 21 Unitary UPS (continued) Main status bits (UPS operating information) Normal : inverter powers load and full backup time available bit 4C4 = 1 Danger : inverter does not power load bit 4C6 = 1 Downgraded : malfunction or environment fault bit 4C5 = 1 Load on battery : fonctionnement en autonomie bit 4C7 = 1 Operating modes The following section describes the different states of a MGETM GalaxyTM 6000 UPS and the addresses of the bits in the system data array. Normal operation Normal: Danger: Downgraded: Load on battery: Q1 closed: Rectifier/charger on: QF1 closed: Inverter connected: Q5N closed: Q3BP open: Q4S closed: SS open: K2S open (if available): bit 4C4 = 1 bit 4C6 = 0 bit 4C5 = malfunction dependent bit 4C7 = 0 bit 40E = 1 bit 408 = 1 bit 400 = 1 bit 484 = 1 bit 498 = 1 bit 497 = 0 bit 496 = 1 bit 499 = 0 bit 494 = 0 Load on battery Normal: Danger: Downgraded: Load on battery: Q1 indifferent: Rectifier/charger off: QF1 closed: Inverter connected: Q5N closed: Q3BP open: Q4S closed: SS open: K2S open (if available): bit 4C4 = 1 bit 4C6 = 0 bit 4C5 = malfunction dependent bit 4C7 = 1 bit 40E = X (N/A) bit 408 = 0 bit 400 = 1 bit 484 = 1 bit 498 = 1 bit 497 = 0 bit 496 = 1 bit 499 = 0 bit 494 = 0 Page 22 - 6739389EN/FB Unitary UPS (continued) Load on Mains 2 Normal: Danger: Downgraded: Load on battery: Q1 indifferent: Rectifier/charger indifferent: QF1 indifferent: Inverter disconnected: Q5N closed: Q3BP open: Q4S closed: SS closed: K2S closed (if available): bit 4C4 = 0 bit 4C6 = 1 bit 4C5 = X (N/A) bit 4C7 = X (N/A) bit 40E = X (N/A) bit 408 = X (N/A) bit 400 = X (N/A) bit 484 = 0 bit 498 = 1 bit 497 = 0 bit 496 = 1 bit 499 = 1 bit 494 = 1 Load on bypass Normal: Danger: Downgraded: Load on battery: Q1 indifferent: Rectifier/charger indifferent: QF1 indifferent: Inverter connected indifferent: Q5N open: Q3BP closed: Q4S indifferent: SS indifferent: K2S indifferent: bit 4C4 = 0 bit 4C6 = 1 bit 4C5 = X (N/A) bit 4C7 = X (N/A) bit 40E = X (N/A) bit 408 = X (N/A) bit 400 = X (N/A) bit 484 = X (N/A) bit 498 = 0 bit 497 = 1 bit 496 = X (N/A) bit 499 = X (N/A) bit 494 = X (N/A) 6739389EN/FB - Page 23 Parallel connected UPS This chapter presents the specific operating aspects and system data provided by the "GTCZ" and "GT2Z" boards in parallel connected UPSs. For more detailed information, please refer to the "system information" section. Block diagram rectifiercharger inverter Q1 Q5N K3N Mains 1 load b e c d QF1 battery Measured quantities b F Mains 1 <1A0> U Mains 1 I Mains 1 <140 to 142> <100 to 102> c F inverter <1A1> U inverter I inverter <143 to 148> <106 to 108> d F load <1A3> U load I load <14F to 154> <10C to 10E> U battery or U dc Battery temperature <155 or 1C0> <1C3> Apparent and active power <180 to 187> e I battery or I dc <115 or 1C1> Battery backup time <1C2> The numbers enclosed by <> are the addresses in the data array. Page 24 - 6739389EN/FB Parallel connected UPS (continued) Main status bits of system operations Normal : inverter powers load and maximum backup time available bit 4C4 = 1 Danger : inverter does not power load bit 4C6 = 1 Downgraded : malfunction or environment fault bit 4C5 = 1 Load on battery : load on battery power bit 4C7 = 1 Operating modes The following section describes the different states of a MGETM GalaxyTM 6000 UPS and the addresses of the bits in the system data array. Normal operation Normal: Danger: Downgraded: Load on battery: Q1 closed: Rectifier/charger on: QF1 closed: Inverter connected: Q5N closed: bit 4C4 = 1 bit 4C6 = 0 bit 4C5 = malfunction dependent bit 4C7 = 0 bit 40E = 1 bit 408 = 1 bit 400 = 1 bit 484 = 1 bit 498 = 1 Load on battery Normal: Danger: Downgraded: Load on battery: Q1 indifferent: Rectifier/charger off: QF1 closed: Inverter connected: Q5N closed: bit 4C4 = 1 bit 4C6 = 0 bit 4C5 = malfunction dependent bit 4C7 = 1 bit 40E = X (N/A) bit 408 = 0 bit 400 = 1 bit 484 = 1 bit 498 = 1 Disconnected Normal: Danger: Downgraded: Load on battery: Q1 indifferent: Rectifier/charger indifferent: QF1 indifferent: Inverter not connected: Q5N open: bit 4C4 = 0 bit 4C6 = 1 bit 4C5 = X (N/A) bit 4C7 = X (N/A) bit 40E = X (N/A) bit 408 = X (N/A) bit 400 = X (N/A) bit 484 = X (N/A) bit 498 = 0 6739389EN/FB - Page 25 Static Switch cubicle This chapter presents the specific operating aspects and system data provided by the "GTCZ" and "GT2Z" boards for MGETM GalaxyTM 6000 "Static Switch" cubicles. For more detailed information, please refer to the "system information" section. Block diagram Q3BP static by-pass switch (SS and K2S*) Q4S a Mains 2 Q5N inverter 1 inverter 2 load b inverter n * : K2S is the contactor that is parallel-mounted with the static switch on devices with an output greater than 800 kVA. Measured quantities a F Mains 2 <1A2> U Mains 2 I Mains 2 <149 to 14E> <109 to 10B> b F load <1A3> U load I load <14F to 154> <10C to 10E> Apparent and active power <180 to 187> The numbers enclosed by <> are the addresses in the data array. Page 26 - 6739389EN/FB Static Switch (continued) Main indicators of system operations Normal : charge alimentée par l'onduleur bit 4C4 = 1 Danger : charge non alimentée par l'onduleur bit 4C6 = 1 Downgraded : anomalie de fonctionnement ou défaut d'environnement bit 4C5 = 1 Operating modes The following section describes the different states of a Static Switch cubicle and the addresses of the bits in the system data array. Normal operation Normal: Danger: Downgraded: Q5N closed: Q3BP open: Q4S closed: SS open: K2S open (if available): Inverters connected to load: bit 4C4 = 1 bit 4C6 = 0 bit 4C5 = malfunction dependent bit 498 = 1 bit 497 = 0 bit 496 = 1 bit 499 = 0 bit 494 = 0 bit 4AE = 1 Load on Mains 2 Normal: Danger: Downgraded: Q5N closed: Q3BP open: Q4S closed: SS closed (if K2S not available): K2S closed (if available): Inverters not connected to load: bit 4C4 = 0 bit 4C6 = 1 bit 4C5 = X (N/A) bit 498 = 1 bit 497 = 0 bit 496 = 1 bit 499 = 1 bit 494 = 1 bit 4AE = 0 Load on bypass Normal: Danger: Downgraded: Q5N open: Q3BP closed: Q4S indifferent: CS indifférent: SS indifferent: Inverter connected indifferent: bit 4C4 = 0 bit 4C6 = 1 bit 4C5 = X (N/A) bit 498 = 0 bit 497 = 1 bit 496 = X (N/A) bit 499 = X (N/A) bit 494 = X (N/A) bit 4AE = X (N/A) 6739389EN/FB - Page 27 System information Message format This section describes the messages exchanged between the "GTC link" communication interface and the external computer based on the JBUS protocol. The length of time after which a message must be interpreted as "not understood" depends on the type of command sent. The table opposite lists maximum response times: Data rate status information only all measurements 1200 Baud 0,5 s 2s 2400 Baud 0,25 s 1s Response time of event (independent of data rate) - inverter start-up and connect : - rectifier-charger startup : - rectifier-charger or inverter stop : 4800 Baud 0,12 s 0,5 s 9600 Baud 0,06 s 0,25 s 30 s 30 s 30 s Example of read data array commands sent by the terminal (address: 20H) For the "responses", refer to the "JBUS protocol" section function 1 and 3. request station data address 0140 length CRC 16 20 function code 03 read voltage array (21 values) read current array (15 values) read global state bits (11 bits) 0015 82 9C 20 03 0100 000F 28 03 20 01 04C0 000B 7A 70 Sample commands command station charger on charger off inverter on inverter off 20 20 20 20 function code 05 05 05 05 bit address 0C00 0C01 0C04 0C05 data FF FF FF FF not used 00 00 00 00 List of variable fields (same for all cubicle types) The binary data and binary commands can be accessed bit or word-wise. The word address and position of the bit in the word can be determined from the bit address: ◗ hundreds and tens digit of bit address = word address; ◗ least significant digit of bit address = bit position. Page 28 - 6739389EN/FB JBUS fields signaling signaling binary data commands counters currents voltages powers frequencies battery adjustments maintenance address in hexadecimal start end 0 5 6 F 40 BF C0 DF E0 FF 100 13 140 17 180 19F 1A0 1BF 1C0 1DF 200 2FF 300 3FF access read / write read read read / write read read read read read read read read CRC 16 89 DB D8 1B C8 1A 99 DA System information (continued) General definitions object switch unit fault control device 0 open off no fault not activated 1 closed on fault activated Signaling field (same for all cubicle types) signaling units data JBUS address hex. word 0 synchronisation counter (MSB) synchronisation counter (LSB) binary times binary times binary times binary times manufacturer's ID model ID (MSB) model ID (LSB) configuration 1 ms 0 without without without without configuration 2 without N/A N/A N/A N/A 1 102 54380 N/A inverter type, same as 200 hardware version software version not used not used state of equipment state of processing not used not used without without measured current units I1 (I phase 1) Mains 1 I2 (I phase 2) Mains 1 I3 (I phase 3) Mains 1 I1 (I phase 1) inverter I2 (I phase 2) inverter I3 (I phase 3) inverter I1 (I phase 1) Mains 2 I2 (I phase 2) Mains 2 I3 (I phase 3) Mains 2 I1 (I phase 1) load I2 (I phase 2) load I3 (I phase 3) load I battery % load % peak load (Ph1) % peak load (Ph2) % peak load (Ph3) A A A A A A A A A A A A A - 4294967295 1 same as 4E same as 4C 2 3 4 5 MSB 6 LSB 6 7 MSB 8 LSB 8 MSB 9 LSB 9 A B C D E F Tables of measured data Current fields Legend: ◗ yes: available in this cubicle; ◗ bat: available in this cubicle if battery installed; ◗ no entry: not available. JBUS address hex. word 100 101 102 106 107 108 109 10A 10B 10C 10D 10E 115 120 121 122 123 type unitary yes yes yes yes yes yes yes yes yes yes yes yes bat yes yes yes yes parallel Static Switch yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes bat yes yes yes yes yes yes yes yes 6739389EN/FB - Page 29 System information (continued) Voltage fields Legend: ◗ yes: available in this cubicle; ◗ no entry: not available. Power fields Frequency fields Legend: ◗ yes: available in this cubicle; ◗ no entry: not available. Page 30 - 6739389EN/FB measured voltage units U12 Mains 1 U23 Mains 1 U31 Mains 1 U1N inverter U2N inverter U3N inverter U12 inverter U23 inverter U31 inverter U1N Mains 2 U2N Mains 2 U3N Mains 2 U12 Mains 2 U23 Mains 2 U31 Mains 2 U1N load U2N load U3N load U12 load U23 load U31 load U battery V V V V V V V V V V V V V V V V V V V V V V power measurements units P1 (load active power) P2 (load active power) P3 (load active power) S1 (load apparent power) S2 (load apparent power) S3 (load apparent power) P (load active power) S1 (load apparent power) % inverter load power factor kW kW kW kVA kVA kVA kW kVA - frequencies measurements F Mains 1 F inverter FMains 2 F load units dHz dHz dHz dHz JBUS address hex. word 140 141 142 143 144 145 146 147 148 149 14A 14B 14C 14D 14E 14F 150 151 152 153 154 155 type unitary yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes JBUS address hex. word 180 181 182 183 184 185 186 187 188 189 type unitary yes yes yes yes yes yes yes yes yes yes JBUS address hex. word 1A0 1A1 1A2 1A3 type unitary yes yes yes yes parallel yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes SS yes yes yes yes yes yes yes yes yes yes yes yes parallel yes yes yes yes yes yes yes yes yes yes SS yes yes yes yes yes yes yes yes yes yes parallel yes yes SS yes yes yes System information (continued) Battery and adjustments fields Legend: ◗ no entry: not available; ◗ yes: available in this cubicle; ◗ bat: available in this cubicle if battery installed; ◗ bat/opt: available if option installed. Inverter type: ◗ 0: unitary; ◗ 1: parallel without static switch; ◗ 2: parallel with static switch; ◗ 3: Static Switch cubicle. battery measurements units U battery I battery battery backup time battery room temperature V A mn °C battery adjustments units inverter type battery installed battery temperat. sensor In (I rated load) Pn (P rated load) A kW JBUS address hex. word 1C0 1C1 1C2 1C3 type unitary yes bat bat/opt bat/opt parallel yes bat bat/opt bat/opt SS JBUS address hex. word 200 201 202 208 209 type unitary yes yes yes yes yes parallel yes yes yes yes yes SS yes yes yes Battery installed: ◗ 0 = no; ◗ 1 = yes. Sensor installed: ◗ 0 = no; ◗ 1 = yes. Tables of binary data Rectifier-charger Legend: ◗ no entry: not available; ◗ yes: available in this cubicle; ◗ bat: available in this cubicle if battery installed. rectifier-charger information B_Etat_QF1 B_Etat_Dech_Bat B_Etat_Ubat_Min B_Etat_Ubat_Aut B_Etat_Tempe_Ht B_Etat_Res1_Ht B_Etat_Vent_Bat B_Etat_Cha_Bat B_Etat_Pont B_Etat_Def_Maj_Cha B_Etat_Q1 B_Etat_Arr_Urg B_Etat_U_Res1 B_Etat_F_Res1 B_Etat_Arr_Prog B_Etat_Lim_Groupe B_Etat_IBat_Aux B_Etat_Egal_Bat B_Etat_Groupe bit meaning bit=0 open not discharging not reached not reached normal not reached no fault not charging off no fault open not activated normal normal not activated not activated not activated not active not activated bit=1 closed discharging min. volt. fault warning outside toleran. outside toleran. fault charging on fault closed activated outside toleran. outside toleran. activated activated activated active activated JBUS address hex. bit word 400 40 401 402 403 404 405 406 407 408 409 40E 411 41 412 413 417 419 41A 41B 41E type unit. bat bat bat bat bat bat yes bat bat yes yes yes yes yes bat bat bat bat yes para. SS bat bat bat bat bat bat yes bat bat yes yes yes yes yes bat bat bat bat yes 6739389EN/FB - Page 31 System information (continued) Inverter Legend: ◗ no entry: not available; ◗ yes: available in this cubicle. Connectivity Legend: ◗ no entry: not available; ◗ yes: available in this cubicle; ◗ >800k: on static switch cubicles higher than 800 kVA. Page 32 - 6739389EN/FB inverter information B_Etat_Su_Mut B_Etat_Def_Maj_Ond B_Etat_Lim_Ond B_Etat_Suth_Mut B_Etat_Aux_Libre B_Etat_Arr_Urg B_Etat_Arr_Forc_Cext B_Etat_Inv_Fréq B_Etat_Arr_Prot_Cext connectivity information B_Etat_Su_Ond B_Etat_Vent B_Etat_Ond_Coup B_Etat_Arr_Inter B_Etat_Cde_Pilote B_Etat_Def_Coup B_Etat_Res2_Ht B_Etat_Arr_Urg B_Etat_K2S B_Etat_Q4S B_Etat_Q3BP B_Etat_Q5N B_Etat_Cde_Cs_Res2 B_Etat_F_Res2 B_Etat_U_Res2 B_Etat_Freq_Auto B_Etat_Su_Res2 B_Etat_Suth_Res2 B_Etat_Suth_Ond B_Etat_Arm_Aux B_Etat_Sans_Trou B_Etat_Ver_Sec B_Etat_Nb_Ond_Suff bit meaning JBUS address hex. bit word 440 44 441 445 446 44C 44D 454 46 465 467 bit=0 no overload no fault no limitation no overload not activated not activated not activated not activated not activated bit=1 overload fault limitation overload activated activated activated activated activated bit meaning JBUS address hex. bit=1 bit word overload 480 48 ventilation fault 482 connected 484 disable 485 synchro. 486 fault 487 outside toleran.48A activated 48D closed 494 49 closed 496 closed 497 closed 498 closed 499 outside toleran.49C outside toleran.49D activated 49F overload 4A0 4A overload 4A1 overload 4A2 fault 4A3 activated 4A4 activated 4A5 sufficient 4AF bit=0 no overload no fault not connected enable not synchro. no fault normal not activated open open open open open normal normal not activated no overload no overload no overload no fault not activated not activated insufficient type unit. yes yes yes yes yes yes yes yes yes para. SS yes yes yes yes yes yes yes yes yes type unit. yes yes yes yes yes yes yes yes par. yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes SS yes yes yes yes yes yes yes yes >800k yes yes yes yes yes yes yes yes yes yes yes yes yes yes System information (continued) Global information Legend: ◗ no entry: not available; ◗ yes: available in this cubicle; Table of control devices Legend: ◗ no entry: not available; ◗ yes: available in this cubicle. global information bit meaning bit=0 B_Etat_Arr_Acq no fault B_Etat_Cde_Batt_Fin no fault B_Etat_Fin_Vie_Batt no fault B_Etat_Cde_Sys_Nor B_Etat_Cde_Sys_Deg B_Etat_Cde_Sys_Dan B_Etat_Cde_Bat_Deg B_Etat_Arr_Urg B_Etat_CS_K2S B_Etat_Coup_ASI B_Etat_Vent_US B_Num_Test_Com B_Reg_Autres B_Reg_Voie B_Mes_Invalides B_Etat_Modifié no fault not downgraded safe not on batteries not activated open disconnected no fault no error not configurated not configurated valid no change commands bit meaning B_Ope_Mar_Cha B_Ope_Arr_Cha B_Ope_Arr_Ond B_Ope_Mar_Ond bit=0 not activated not activated not activated not activated Telemonitoring information information Legend: ◗ no entry: not available; ◗ yes: available in this cubicle. reason for call (high transitions) JBUS address hex. bit=1 bit word fault 4C0 4C backup time 4C1 end battery 4C2 obsolete normal 4C4 downgraded 4C5 unsafe 4C6 on batteries 4C7 activated 4C8 closed 4C9 connected 4CA fault 4DD error 4E9 4E configurated 4EA configurated 4EB invalid 4EC change 4EF bit=1 activated activated activated activated bit meaning bit=0 no transition JBUS address hex. bit word C00 C0 C01 C04 C05 bit=1 transition type unit. par. SS yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes type unit. yes yes yes yes par. SS yes yes yes yes JBUS address type hexadecimal bit word unit. par. SS (same 50 yes yes yes structure as word 4C) reason for call (low transitions) no transition transition main number invalid secondary number invalid valid invalid 520 valid invalid 528 (same 51 yes yes yes 52 yes yes yes yes yes yes structure as word 4C) 6739389EN/FB - Page 33 System information (continued) Glossary of information descriptors (data words at address 40 to 4E) Every bit is listed according to the following format: bit address: description (bit = 0 / bit = 1). Word address: 40 400: battery circuit breaker (0=open/1=closed) Battery protection circuit breaker "QF1" is located near the battery and is "on" (closed) during normal operation. When it either trips or is turned "off" (open) the load is no longer protected since battery power is no longer available if Mains 1 fails. 401: battery discharging (0=not discharging/1=discharging) The inverter powers the load. Mains 1 is either not available or outside tolerances and the inverter is battery powered. 402: minimum battery voltage (0=not reached/1=min. volt. fault) A fault indicates that the minimum battery voltage has been reached during Load on battery and the inverters it supplies are stopped. If Mains 2 is not available, which is generally the case, the load not longer receives power. 403: low battery shutdown warning (0=not reached/ 1=warning) The warning indicates that the end of backup time is imminent. It is only applicable when the inverters operate on battery power. 404: battery temperature (0=normal/1=outside tolerances) This information only exists if the system is equipped with the "Temperature Monitor" option. It tells the user that the temperature of the battery is outside the allowable range. The rectifiercharger circuit is switched so that the battery charging current becomes zero. The battery is no longer being recharged (battery protection). Page 34 - 6739389EN/FB 405 : Mains 1 voltage (0=normal/ 1=outside tolerances) Indicates that the Mains 1 power supply voltage is outside tolerances and the inverter on battery power. the protection devices to disconnect the units from Mains 1 and Mains 2, the load no longer receives power and the units are completely disconnected. 406 : battery room ventilation (0=no fault/1=fault) Informs the user of a battery room ventilation fault. The rectifiercharger circuit is switched so that the battery charging current becomes zero. The battery is no longer being recharged. It prevents vented led-acid batteries from giving off hydrogen gas The user must remedy the ventilation problem. 412: rectifier-charger input voltage (0=normal/1=outside tolerances) The rectifier-charger stops operating when the Mains 1 phaseto-phase voltage is outside tolerances. 407: battery charging (0=not charging/1=charging) Informs the user whether the battery is currently being recharged (only valid for vented lead-acid batteries). 408: rectifier-charger status (0=off/1=on) Gives the status of the rectifiercharger circuit. It stops every time Mains 1 power fails. In this case the load is battery powered via the inverter. 409: major rectifier-charger fault (0=no fault/1=fault) Informs the user of a major rectifiercharger fault requiring after-sales servicing. 40E: Mains 1 input switch (0=open/1=closed) "Q1" Mains 1 input switch which powers the rectifier-charger. Normally the switch is closed or "on". The switch can be opened to disconnect the unit from Mains 1 for servicing. Word address: 41 411: emergency off switch (0=not activated/1=activated) Normally-closed switch connected to the units. When activated, the rectifier-charger circuits and the inverters stop operating. The "QF1" battery circuit breaker is also opened. If the "emergency off" also tripped 413: rectifier-charger input frequency (0=normal/1=outside tolerances) The rectifier-charger stops operating when the Mains 1 frequency is outside tolerances. 417: gradual rectifier-charger shutdown (0=not activated/ 1=activated) Indicates that the rectifier-charger received an external command to gradually stop operating (e.g. gradual load-shedding when using power from engine generator sets). 419: engine generator set current limiting (0=not activated/ 1=activated) Informs the user that the rectifiercharger has received an external command to limit the current drawn from Mains 1. The additional power required by the inverter is supplied by the battery (which discharges). Example: operating from a generator that delivers insufficient power. 41A: battery current limiting (0=not activated/1=activated) The rectifier-charger received an external command to limit the current that charges the battery. Normal battery charging is resumed when Mains 1 returns. Example: operating from a generator that delivers insufficient power to supply load and charge batteries. Note: the current limit is programmable. System information (continued) 41B: battery equalization (0=not active/1=active) The rectifier-charger has been manually switched to equalization mode, to equalize battery cell voltages. This action stops all inverters powered by the battery (if they were not already stopped). 41E: operation on enginegenerator set (0=not activated / 1=activated) Indicates that the rectifier-charger is supplied by an engine-generator set and not by the normal Mains 1 power supply. Word address: 44 440: inverter stack overload (0=no/1=overload) Indicates an overload condition due to a load power factor exceeding 0.9. 441: major inverter fault (0=no/ 1=fault) Informs the user of an inverter fault requiring after-sales servicing. 445: inverter output current limiting (0=no/1=active) Informs the user that an overload exceeding 1.6 In has occurred at the output: the inverter stops operating. 446: inverter thermal overload (0=no/1=overload) Informs the user that the output is overloaded by a factor between 1 and 1.6 In: the inverter stops operating. 44C: outside contact (0=not activated/1=activated) Normally open switch. Initiates the actions that have been configured using the after-sales "Soft Tunor" computer software. Possible actions when activated: ◗ no action; ◗ inverter off; ◗ forced inverter shutdown; ◗ conditional inverter shutdown; ◗ frequency change (when powering on the unit) with respect to the frequency configured by the after-sales "Soft Tunor" computer software (i.e. 50Hz to 60Hz or vice versa). 44D: emergency off switch (0=not activated/1=activated) Normally-closed switch connected to the units. When activated, the rectifier-charger circuits and the inverters stop operating. The "QF1" battery circuit breaker is also opened. If the "emergency off" also trips the protection devices to disconnect the units from Mains 1 and Mains 2, the load no longer receives power and the units are completely disconnected. Word address: 46 464: forced inverter shutdown (0=not activated / 1=activated) Indicates to the user that a shutdown of the inverter will result in transfer of the load to Mains 2 with the risk of a 0.8 second interruption in the supply of power to the load. 465: frequency conversion (0=not activated / 1=activated) Indicates that the MGETM GalaxyTM 6000 UPS is operating as a frequency converter between the input and the output (50 Hz / 60 Hz). 466: conditional inverter shutdown (0=not activated / 1=activated) Indicates to the user that a shutdown of the inverter will take place only if the load transfer conditions to Mains 2 are correct to avoid an interruption in the supply of power to the load. Word address: 48 480: inverter overload (0=no/ 1=overload) Informs the user that the load is drawing more than the rated UPS output. 482: ventilation of the battery cabinets (0=no fault / 1=fault) Indicates to the user that ventilation in a battery cabinet is incorrect due to a fan fault or shutdown. This fault does not result in UPS shutdown. This information is available only on European versions of the MGETM GalaxyTM 6000 UPS. 484: inverter connected to the load (0=not connected/ 1=connected) The inverter is operating and powers the load. 485: inverter off disable (0=enabled/1=disabled) The inverter off command is disabled. 486: synch with Mains 2 (0=not synch/1=synch) The inverter may operate without its frequency synchronized to that of Mains 2 (i.e. free-running operation); in this case, it operates at an accurate (within 0.05 Hz) fixed frequency. Alternatively, the inverter may be operated with its frequency synchronized to that of Mains 2. 487: transfer fault (0=no fault/ 1=fault) Informs the user of a fault on the static switch, used to transfer the load between Mains 2 and inverter output. After-sales servicing is required. 48A: Mains 2 voltage outside tolerances (0=normal / 1=outside tolerances) Indicates to the user that the Mains 2 backup power supply voltage is outside tolerances. A transfer of the load to the Mains 2 backup power supply will result in a 0.8 second interruption in the supply of power to the load or may not take place. 48D: emergency off switch (0=not activated/1=activated) Normally-closed switch connected to the units. When activated, the rectifier-charger circuits and the inverters stop operating. The "QF1" battery circuit breaker is also opened. If the "emergency off" also tripped the protection devices to disconnect the units from Mains 1 and Mains 2, the load no longer receives power and the units are completely disconnected. 6739389EN/FB - Page 35 System information (continued) Word address: 49 494: contactor K2S (0=open/ 1=closed) Indicates the position of contactor K2S . Contactor K2S is connected in parallel with the static switch on the Mains 2 line on certain high output units. It is installed in staticswitch cubicles with power ratings over 400 kVA. 496: Mains 2 input switch (0=open/1=closed) Switch "Q4S" is located on the Mains 2 phases at the input of the static switch (on the bypass line). The switch is normally closed. 497: maintenance bypass switch (0=open/1=closed) Switch "Q3BP" bypasses the static switch and connects Mains 2 directly to the load. This switch is normally open. When closed (with "Q4S" and "Q5N" open), the load can continue to be powered while the UPS is isolated for servicing. 498: inverter output switch (0=open/1=closed) Switch "Q5N" is located at the output of the inverter and is used to disconnect the load from the inverter (or from the output busbars when several units are connected in parallel). This switch is normally closed. 499: static switch status (0=open/1=closed) The static switch on Mains 2 is normally open (inverter powers the load). The load is transferred to Mains 2 by closing the static switch when the inverters are no longer capable of delivering the required power (overload, end of backup time or internal error). 49C: Mains 2 frequency (0=normal/1=outside tolerances) When the frequency of Mains 2 is outside tolerances, load transfer from inverter to Mains 2 will include an interruption of 0.8 s or will not take place. 49D: Mains 2 voltage (0=normal/ 1=outside tolerances) When the phase-to-phase Mains 2 Page 36 - 6739389EN/FB input voltage is outside tolerances, load transfer from inverter to Mains 2 will include an interruption of 0.8 second. 49F: free-running frequency request (0=not activated/ 1=activated) Indicates that the inverter received an external command to desynchronize its output frequency from the frequency of Mains 2. Word address: 4A 4A0: static bypass (Mains 2) overload (0=no/1=overload) The load, supplied via the static bypass line (Mains 2), is drawing more than the rated current but continues to be supplied by Mains 2. 4A1: static bypass (Mains 2) thermal overload (0=no/ 1=overload) Informs the user that the load is no longer powered by Mains 2 due to an extended overload condition. 4A2: inverter thermal overload (0=no/1=overload) Informs the user that the load is overloaded by a factor between 1 and 1.6 In: the inverter stops operating. 4A3: auxiliary cubicle fault (0=no fault / 1=fault) Indicates to the user that the fault auxiliary contact connected to the cubicle has been activated. This information is available only on U.S. versions of the MGETM GalaxyTM 6000 UPS. 4A4: transfer to Mains 2 with interrupt prohibited (0=not activated/1=activated) An auxiliary command prohibits transfer to Mains 2 with power interruption. 4A5: transfer lockout (0=not activated/1=activated) The inverter received an auxiliary command prohibiting transfer to Mains 2. The load is totally dependent on inverter power. If the inverter stops (internal fault), the load will no longer receive power. 4AF: inverter quantity (0=insufficient/1=sufficient) This only concerns systems with parallel connected inverters and a static switch cubicle. It informs the user that the number of inverters to be connected to the load is insufficient to supply the necessary power. Additional inverter(s) must be turned on so that the inverters can start supplying the power to the load. If this is not the case, Mains 2 continues to supply the power. Word address: 4C (summary of operating information) 4C0: acquisition fault (0=no fault / 1=fault) Indicates an acquisition fault for the internal analogue or logic values of the "GTCZ" or "GT2Z" communication board. 4C1: battery backup time (0=no fault/1=backup time end) The computed "remaining backup time" is less than the amount configured in the unit. 4C2: end of battery life (0=no fault / 1=end of battery life) Indicates that the battery has reached its maximum service life and should be replaced. 4C4: system normal, load protected (0=not normal/ 1=normal) Indicates that the inverter powers the load and that the full battery backup time is available if Mains 1 fail. The unit is operating normally. Note: for parallel connected inverter cubicles, this only refers to the output power supplied by that specific unit. The load may be unprotected if more than one inverter is required to supply the load power. All required inverters in the system or the static switch cubicle if it exists must therefore be checked. 4C5: system downgraded due to malfunction (0=not downgraded/ 1=downgraded) Indicates a malfunction or environment fault; nevertheless the inverter can still power the load. System information (continued) malfunctions: static switch cubicle ventilation fault, ◗ static switch control fault, ◗ environment faults: ◗ battery temperature outside tolerances, ◗ overload exceeding 5%, ◗ Mains 2 voltage, frequency or phase outside tolerances with respect to inverter. ◗ ◗ 4C6: unsafe operation, load unprotected (0=safe/1=unsafe) Indicates that: ◗ Mains 2 powers the load due to inverter shutdown (manual or due to an overload or internal fault) or due to opening "Q5N" at the inverter output; ◗ not able to rely on battery backup because circuit breaker "QF1" is open. Note: for parallel connected inverters this only refers to the specific unit. The load may still be protected because more than one inverter is supplying power. 4C7: operating on battery power (0=no/1=on battery power) Indicates that the unit is operating on battery power because: ◗ Mains 1 voltage failure or dip; ◗ insufficient Mains 1 power (e.g. engine generator set) with extra energy required supplied by the battery. 4C8: emergency off switch (0=not activated/1=activated) Normally-closed switch connected to the units. When activated, the rectifier-charger circuits and the inverters stop operating. The "QF1" battery circuit breaker is also opened. If the "emergency stop" also tripped the protection devices to disconnect the units from Mains 1 and Mains 2, the load no longer receives power and the units are completely disconnected. 4C9: power supplied via SS or K2S (0=open/1=closed) Indicates that the static switch or the mechanical switch on the Mains 2 backup line is closed. The load is supplied by Mains 2. 4CA: inverter connected (0=disconnected/1=connected) Indicates that the inverter is in operation and supplying the load. Glossary of telemonitoring information descriptors (data words at address 50 to D4) Word address: 4D 4DD: cubicle ventilation (0=no fault / 1=fault) Indicates to the user that ventilation in a cubicle is incorrect due to a fan fault or shutdown. This fault does not result in UPS shutdown. This information is available only on U.S. versions of the MGETM GalaxyTM 6000 UPS. Word address: 50 The causes of high transition alarms followed by a call from the UPS site to the central monitoring site are logged in this word. Word structure is similar to that of word 4C. Word address: 51 Word address: 4E (summary of communication interface information) 4E9: communication interface test error (0=no error/1=error) Error free communications can no longer be guaranteed. 4EA: unit in configuration mode (0=no config./1=config) The after-sales "Soft Tunor" computer software is connected to the cubicle, blocking all remote commands. 4EB: remote setting (0=no setting / 1=setting) Indicates to the user that the Soft Tunor after-sales-support computer tool has been connected to the communication channel. 4EC: invalid measurements (0=valid/1=invalid) The communication interface receives invalid measurement data and status information from the cubicle. 4EF: change in status (0=no change / 1=change) Indicates a change in status of at least one indicator between two reads of logical data. This information can be reset by the device connected to the communication channel. The causes of low transition alarms followed by a call from the UPS site to the central monitoring site are logged in this word. Word structure is similar to that of word 4C. Word address: 52 520: invalid telephone number for main telemonitoring site (0=valid / 1=invalid) Indicates that calls from the UPS site to the central telemonitoring site consistently fail. The number of the telemonitoring site is therefore declared invalid and no longer used. A second set of calls is then undertaken using the backup number. The telephone number is reinstated: ◗ on reception of a new communication configuration using the Soft Tunor after-sales-support computer tool, ◗ when the "GTCZ" or "GT2Z" communication board is deenergised. 528: invalid telephone number for secondary telemonitoring site (0=valid / 1=invalid) Indicates that calls from the UPS site to the secondary telemonitoring site consistently fail. The number of the telemonitoring site is therefore declared invalid and no longer used. 6739389EN/FB - Page 37 System information (continued) The telephone number is reinstated: ◗ on reception of a new communication configuration using the Soft Tunor after-sales-support computer tool, ◗ when the "GTCZ" or "GT2Z" communication board is deenergised. Word address: C1 C10: call reset (0= not activated / 1=activated) Call reset command issued by the central telemonitoring site. The information bits that provoked the call to the central telemonitoring site are reset. C11: return call (0= not activated / 1=activated) Return call command issued by the central telemonitoring site. The UPS site recalls the central telemonitoring site following a time delay of approximately 30 seconds. C14: status change reset (0= not activated / 1=activated) Indicates that the central telemonitoring site issues a reset command for the status change bit at address 4EF. Page 38 - 6739389EN/FB
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 38 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:33bb5f5b-70b1-4eec-86fd-a4c75677b221 Producer : Acrobat Distiller 6.0 (Windows) Keywords : Create Date : 2008:10:08 17:10:37+02:00 Creator Tool : Adobe PageMaker 6.5 Modify Date : 2008:10:08 17:10:37+02:00 Document ID : uuid:90a3fbb7-f7ac-4cf8-a3d4-191f0c8b23df Format : application/pdf Description : 01NT389E Title : 01NT389E Creator : VAN HERCK Author : VAN HERCK Subject : 01NT389EEXIF Metadata provided by EXIF.tools