 Xserve (Late 2006)

Processor Heat Sink

Replacement Instructions
Follow the instructions in this document carefully. Failure to follow these instructions could
damage your equipment and void its warranty.
Online instructions are available at http://www.apple.com/support/diy/.

Working Safely Inside the Xserve
Always touch the Xserve enclosure to discharge static electricity before you touch any
components inside the Xserve. To avoid generating static electricity, do not walk around the
room until you have finished working inside the server and have replaced the cover. To minimize
the possibility of damage due to static discharge, wear an antistatic wrist strap while you work
inside the Xserve.
Warning: Always shut down the Xserve and disconnect the power cords before opening
it to avoid damaging its internal components or the components you are installing. Don’t
open the server while it is turned on. Even after you shut down the Xserve, its internal
components can be very hot. Let it cool before you open it.

Tools Required
The following tools are required for this procedure:
Phillips #1 screwdriver
•
Antistatic wrist strap (if available)
•
Alcohol wipe for cleaning processor (supplied with the part)
•
Thermal grease syringe for replacing thermal grease on processor (supplied with the part)
•

Removing the Xserve from a Rack
1.

Alert users that the server will be unavailable for a period of time.

2.

Shut down the Xserve (see the Xserve User’s Guide for help) and then wait to let the Xserve
internal components cool.

073-1096 Rev. A

Warning: Always shut down the Xserve before opening it to avoid damaging its internal
components or the components you want to install or remove. Don’t open the Xserve
or try to install or remove items inside while it is turned on. Even after you shut down
the Xserve, its internal components can be very hot. Let it cool down for 5 to 10 minutes
before you open it.
3.

Unplug all cables from the Xserve.
Note: If you have trouble releasing a cable from the back panel, try using a small screwdriver
or other flat tool to depress the tab on the cable connector.

4.

To avoid inadvertently unlatching a drive module during handling, use the enclosure key to
lock the enclosure lock on the front panel.

5.

Touch the server’s metal case to discharge any static electricity.

6.

Loosen the thumbscrews at both ends of the front panel.

7.

Grasp the thumbscrews and pull the Xserve forward until the safety latches engage (about
halfway out of the rack).
Latches

Thumbscrews

8.

When the safety latches engage, grip the Xserve where it emerges from the rack, press down
on the latch tabs with your thumbs, and slide the Xserve the rest of the way out of the rack.

9.

Set the Xserve on a flat surface and unlock it.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

Opening the Xserve
Loosen the thumbscrews at the back of the top cover and slide the cover back and up to remove
it. If you have difficulty removing the cover, check the enclosure lock on the front panel.
Warning: Even after you shut down the Xserve, its internal components can be very hot. Let
it cool before you open it.
Important: To minimize the possibility of damage to Xserve components due to static discharge,
wear an antistatic wrist strap, if possible, while you work inside the Xserve.
Slide the cover back and lift it off.

Unscrew the two
captive thumbscrews.

Removing the Installed Processor Heat Sink
Note: Before you can remove a processor heat sink, you must remove the airflow duct.

Airflow Duct
1.

Loosen the five Phillips screws that fasten the airflow duct to the fan array.

2.

Pull up on either side of the airflow duct, and lift it straight up and out of the Xserve.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

Caution: Try not to completely remove the screws from the airflow duct. Tiny black rubber
washers hold these screws captive on the underside of the airflow duct. If the screws are
completely removed, these washers can easily fall into the enclosure and become lost.

Processor Heat Sink
Note: Although the illustrations in this procedure are based on the heat sink that is farthest from
the DIMM slots (CPU B), the steps are the same if you are replacing the heat sink for CPU A.
1.

Loosen the four screws securing the heat sink in the order indicated below.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

Important: Each heat sink is connected to the logic board by a small 2-pin thermal sensor
cable. Be careful not to pull on the wire as you lift each heat sink enough to disconnect the
cable from the logic board.
2.

Slowly lift the heat sink off the processor just far enough that you can reach the sensor cable
connector. You might feel some resistance from the thermal grease that binds the heat sink
to the processor.

3.

Pull on the connector, not the wires, to disconnect the sensor cable from the logic board.

4.

Lift the heat sink straight up and out of the enclosure.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

Installing the Replacement Processor Heat Sink
Note: The thermal bond between the processor heat sink and the processor requires thermal
grease for proper operation. Every time you remove or replace the processor heat sink, you must
replace the thermal grease on the processor below the heat sink. New grease and an alcohol
wipe for cleaning off the previous grease are included with the replacement heat sink. Steps 1–9
below explain how to clean the processor and apply the new grease.
1.

Release the latch on the metal processor holder for the processor.

2.

Rotate the top of the holder to the open position.

3.

Carefully lift the processor out of the holder.
Important: When removing or installing a processor, always hold the processor by the edges.
Be extremely careful not to touch the gold pins on the bottom of the processor, as this type
of connector is very sensitive to contamination. Also be careful not to touch the gold pins in
the processor socket on the logic board.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

4.

Clean off any existing thermal grease on the top face of the processor using the alcohol wipe
provided with the replacement part, being careful not to get any thermal grease on the
processor contacts.

5.

Apply the contents on a single syringe of thermal grease (approximately 4.5 cc) to the top
surface of the processor.
Important: Be sure not to get any grease anywhere on the processor other than the very
top, flat surface that directly contacts the heat sink.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

6.

Use the edge of the package that the alcohol wipe came in as a spatula to spread the
thermal grease evenly over the entire top surface of the processor. Scrape off any excess
grease with the package edge, then discard the package.

7.

Holding the processor by its edges only, replace the processor into its holder on the logic
board.
Note: When installing the processor on the logic board, align the processor notch with the
tab on the processor holder, as illustrated. Then lower the processor straight down onto the
socket.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

8.

Rotate the top of the holder to the closed position.

9.

Engage the latch on the metal processor holder.

10. Holding the heat sink in one hand, reconnect the 2-pin thermal sensor cable for the heat
sink to the logic board.
Note: Make sure the connector on the sensor cable is oriented as illustrated, with the gold
fingers facing up.

11. Carefully seat the heat sink over the processor, aligning the four screws with the holes in the
logic board.
12. Tighten the four captive Phillips mounting screws for the heat sink in the order indicated
below. Do not over-tighten the screws.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 

Replacing the Airflow Duct
1.

Lower the airflow duct into position on the logic board.
Note: When installing the airflow duct, be sure to route both the front panel board cable and
the backplane-to-logic board I/O cable inside the channel under the left side of the duct.

2.

Ensure the airflow duct fits flush all over, and does not protrude above the enclosure.
Note: Be careful when working with any black foam pieces that are part of the airflow duct
or the logic board.

3.

Tighten the five Phillips screws that fasten the airflow duct to the fan array, in the order
shown, to prevent the duct from warping. Do not overtighten the screws.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 10

Closing the Xserve
1.

Replace and secure the cover.

2.

Slide the Xserve back into the rack, and tighten the front thumbscrews to secure the Xserve
in the rack.

3.

If the server case was locked, use the enclosure key to lock the security lock on the front
panel.

 Apple Computer, Inc.
© 2006 Apple Computer, Inc. All rights reserved.
Under the copyright laws, this document may not be copied, in whole or in part, without the
written consent of Apple.
Every effort has been made to ensure that the information in this document is accurate. Apple is
not responsible for printing or clerical errors.
Apple
1 Infinite Loop
Cupertino, CA 95014-2084
USA
+ 1 408 996 1010
http://www.apple.com
Apple, the Apple logo, Mac, Macintosh, and Xserve are trademarks of Apple Computer, Inc.,
registered in the U.S. and other countries.

Xserve (Late 2006) Processor Heat Sink Replacement Instructions 11



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 11
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:eb5c545a-701b-11db-ab2f-000393bb8152
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Create Date                     : 2006:11:09 09:57:23-07:00
Metadata Date                   : 2006:11:09 09:58:35-07:00
Modify Date                     : 2006:11:09 09:58:35-07:00
Creator Tool                    : Adobe InDesign CS2 (4.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 6510 bytes, use -b option to extract)
Instance ID                     : uuid:c7e048d8-701b-11db-a93a-000393bb8152
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:a70bd20c-6755-11db-83e2-994b60f6d588
Derived From Instance ID        : a70bd20b-6755-11db-83e2-994b60f6d588
Derived From Document ID        : adobe:docid:indd:f22d3d31-6730-11db-83e2-994b60f6d588
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00
Manifest Placed Y Resolution    : 72.00, 72.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00, 180.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:E4798E6C300011DB895AFA0C65045F70, uuid:725D3A12496811DBAA4D8559EDBA0203, uuid:70204B7C641C11DBBB20814D584047D2, uuid:70204B7C641C11DBBB20814D584047D2
Manifest Reference Document ID  : uuid:34E7F69C221011DB8BDFADE00337BAF4, uuid:C2B15E5621DA11DB9249C15C0856FFBF, adobe:docid:photoshop:68024e37-5eba-11db-8d70-f403156c3972, adobe:docid:photoshop:712be5ac-5eb4-11db-8d70-f403156c3972, adobe:docid:photoshop:2d350096-60eb-11db-94e7-ba37e651df38, adobe:docid:photoshop:bf65d812-5e8a-11db-8d70-f403156c3972, adobe:docid:photoshop:312a37c6-5eb3-11db-8d70-f403156c3972, adobe:docid:photoshop:fd22ac6d-5eb6-11db-8d70-f403156c3972, adobe:docid:photoshop:b80a4eae-5eb7-11db-8d70-f403156c3972, adobe:docid:photoshop:3fbc4218-5eb8-11db-8d70-f403156c3972, adobe:docid:photoshop:3fbc421e-5eb8-11db-8d70-f403156c3972, adobe:docid:photoshop:6020a0dd-60ea-11db-94e7-ba37e651df38, adobe:docid:photoshop:fd22ac64-5eb6-11db-8d70-f403156c3972, adobe:docid:photoshop:2d350096-60eb-11db-94e7-ba37e651df38, adobe:docid:photoshop:f0ebe5b8-5eb4-11db-8d70-f403156c3972, adobe:docid:photoshop:f6324abd-612e-11db-94e7-ba37e651df38
Format                          : application/pdf
Creator                         : Adobe InDesign CS2 (4.0.4)
Title                           : Xserve Intel (Late 2006) DIY Procedure for Heatsink (Manual)
Keywords                        : kmanual, kxserve, kintel
EXIF Metadata provided by EXIF.tools

Navigation menu