Applied Wireless Identifications Group R32EA031 RFID Reader User Manual users manual

Applied Wireless Identifications Group Inc. RFID Reader users manual

users manual

Download: Applied Wireless Identifications Group R32EA031 RFID Reader User Manual users manual
Mirror Download [FCC.gov]Applied Wireless Identifications Group R32EA031 RFID Reader User Manual users manual
Document ID691729
Application IDdtzJL47Plzi/lYIe3NTuHw==
Document Descriptionusers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize26.55kB (331883 bits)
Date Submitted2006-08-09 00:00:00
Date Available2006-08-09 00:00:00
Creation Date2006-07-28 19:26:01
Producing SoftwarePDFXC Library (version 2.5).
Document Lastmod0000-00-00 00:00:00
Document Titleusers manual

MPR-3014WF-xM
-1-
Doc# 041314
SENTINEL-SENSE MPR-3014
MPR-3014WF-xM
Installation & Operation Manual
AWID PROPRIETARY
MPR-3014WF-xM
-2-
Doc# 041314
COPYRIGHT ACKNOWLEDGEMENTS
The contents of this document are the property of Applied Wireless Identifications Group, Inc.
(AWID) and are copyrighted. All rights reserved. Any reproduction, in whole or in part, is
strictly prohibited. For additional copies of this document please contact:
AWID
18300 Sutter Blvd
Morgan Hill, CA 95037
http://www.AWID.com
The information contained herein has been carefully checked and is believed to be accurate,
no responsibility is assumed for inaccuracies. AWID reserves the right to make changes
without prior notice. This document is not covered by any warranty either expressed or
implied. Any comments, corrections or additions to the contents of this document should be
directed to AWID at the above address.
Copyright 2006 AWID, Printed in USA.
All other trademarks are the property of their respective owners.
FCC COMPLIANCE
This equipment has been tested and found to be in compliance with the limits for FCC Part 15,
Class A digital device. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with instruction manual, may cause harmful interference with radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own
expense.
The users are prohibited from making any change or modification to this product, any
modification to this product shall void the user s authority to operate under FCC Part 15
Subpart A Section 15.21 regulations.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference and, (2) this device must
accept any interference received, including interference that may cause undesired
operation.
The antenna(s) used for this transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
INDUSTRY C ANADA COMPLIANCE
Operation is subject to the following two conditions: (1) this device may not cause
interference and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
AWID PROPRIETARY
MPR-3014WF-xM
-3-
Doc# 041314
This device has been designed to operate with antennas described below, and having a
maximum gain of 6 dBi. Antennas not as described or having a gain greater than 6 dB
are strictly prohibited for use with this device. The required antenna impedance is 50
ohms. AWID, model ANT-915CPS-A; 5.7 dBi Circular polarized antenna (Patch).
To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power (EIRP) is not more
than that required for successful communication.
C AUTION:
Antenna should be positioned so that personnel in the area for prolonged periods may
safely remain at least 23 cm (9 in) in an uncontrolled environment from the antenna s
surface. Observe FCC OET Bulletin 56 Hazards of radio frequency and electromagnetic
fields and Bulletin 65 Human exposure to radio frequency electromagnetic fields.
AWID PROPRIETARY
MPR-3014WF-xM
-4-
Doc# 041314
Table of Content
1.
INTRODUCTION ............................................................................................................. 5
1.1.
1.2.
2.
SPECIAL FEATURES ....................................................................................................... 5
MODEL NUMBER ASSIGNMENT ..................................................................................... 6
SPECIFICATIONS ........................................................................................................... 7
2.1. CHANNEL FREQUENCY TABLE ...................................................................................... 7
2.2. INPUT AND OUTPUT INTERFACES & CONNECTOR PIN ASSIGNMENT ................................ 7
2.2.1.
General Purpose Input/Output ............................................................................. 8
2.2.2.
RS-232 ................................................................................................................. 8
2.3. MEASURING READ DISTANCE ....................................................................................... 8
3.
INSTALLATION PROCEDURE ..................................................................................... 8
3.1. PARTS LIST ................................................................................................................... 8
3.2. PREPARATION FOR INSTALLATION ................................................................................. 9
3.2.1.
Bench Top Verification ........................................................................................ 9
3.2.2.
Aiming of Antenna................................................................................................ 9
3.3. INSTALLATION STEPS .................................................................................................. 10
4.
NOTES ON SOFTWARE PROGRAMMING AND SYSTEM OPERATION............. 11
4.1.
SET UP AND SYSTEM OPERATION .............................................................................. 11
4.1.1.
Setting Up MPR-3014WF-xM ............................................................................ 11
4.1.2.
Running a Custom Software Application or the AWID Demo Program............... 11
4.1.3.
Operating Modes ............................................................................................... 11
4.2. USERS NOTE ................................................................................................................ 11
FOR SYSTEM INTEGRATORS AND/OR SOFTWARE DEVELOPERS........................................... 11
FOR CUSTOM SYSTEM USERS......................................................................................... 11
FOR DEMO SOFTWARE USERS ........................................................................................ 12
5.
APPENDIX ...................................................................................................................... 12
5.1.
SAMPLE GPIO APPLICATION....................................................................................... 12
................................................................................................................................................................................................................................
NOTE: READ AND USE THIS MANUAL.
FAILURE TO FOLLOW THE INSTALLATION (SET UP) GUIDE MAY RESULT IN
POOR PERFORMANCE OR EVEN CAUSE PERMANENT DAMAGE TO THE
READER, THUS VOIDS THE PRODUCT WARRANTY.
AWID PROPRIETARY
MPR-3014WF-xM
-5-
Doc# 041314
1. INTRODUCTION
AWID's Sentinel-Sense MPR-3014 WinCE mono-static reader family MPR-3014WF-xM
consists of two versions of multi-antenna Radio Frequency IDentification (RFID) readers
each with an on-board WinCE.
Reader Versions
MPR-3014WF-QM-NA (WinCE, Fixed, Quad-Ant, Mono-static & North America)
MPR-3014WF-OM-NA (WinCE, Fixed, Octal-Ant, Mono-static & North America)
I/O Interface
One unique configuration for the MPR-3014WF-xM readers is the possibility of having
RS-232 interface and Ethernet interface simultaneously present at the reader data input
ports. To arbitrate possible data collision, the reader determines that local entry always
dominates. Therefore, when both Ethernet commands and serial commands are
present, serial command will dominate. This arbitration process is automatic and
transparent to the user.
MPR-3014WF-xM are long-range (12 to 25 feet, tag dependent) readers with general
purpose digital I/O (GP I/O four (4) inputs four (4) outputs) that work with all leading
passive UHF passive tags. Each of these readers comes with a unique combination of
long read range, small size, and low power consumption. Its primary applications are
asset management & tracking, and fleet management applications.
The MPR-3014WF-QM-NA reader is delivered with the following components and
accessories:
MPR reader MPR-3014WF-QM-NA , firmware Ver. 5.XXN
Antenna 4 EA ANT-915-CPS-A
Cable 4 EA RTC08/16/24 (coax cable 8/16/24 feet, Reverse TNC)
The MPR-3014WF-OM-NA reader is delivered with the following components and
accessories:
MPR reader MPR-3014WF-OM-NA, firmware Ver. 5.XXN
Antenna 8 EA ANT-915-CPS-A
Cable 8 EA RTC08/16/24 (coax cable 8/16/24 feet, Reverse TNC)
In order to control the MPR-3014WF-xM readers you will need the following:
·
·
·
PC running Windows1 98 or higher, CD-ROM drive, Network connection
Host software (AWID s demo software or your own custom software).
RFID Tags (EPC C0, C1 Gen 1 & 2, ISO Type B, EPC V1.19 Rev.2)
1.1. SPECIAL FEATURES
Though MPR-3014WF-xM can also be controlled from a non-Windows programming platform, AWID
demo and FW upgrade programs are applications to run in Windows.
AWID PROPRIETARY
MPR-3014WF-xM
·
·
·
·
·
-6-
Doc# 041314
Multi-Protocol: EPC C0, C1 Gen 1 & 2, ISO Type B, EPC V1.19 Rev.2
Thin passive tags with long-range performance
High performance circular polarized antenna
TCP/IP and four each optically isolated GP I/O
Splash proof design for indoor or outdoor applications
1.2. MODEL NUMBER ASSIGNMENT
Multi-Antenna Readers: MPR-3014WF-xM-YZ
MPR Multiple-protocol RFID
WF WinCE, Fixed-location
x Number of antenna
M Mono-static
YZ Two letter web address for country/regional code
EXAMPLES:
MPR-3014WF-QM-TW for WinCE, fixed, 4-monostatic ant, Taiwan
MPR-3014WF-OM-SG for WinCE, fixed, 8-monostatic ant, Singapore
AWID PROPRIETARY
MPR-3014WF-xM
-7-
Doc# 041314
2. SPECIFICATIONS
Common RF Specifications (North America Versions only)
Transmit frequency................................................. 902-928 MHz (ASK)
Receiver frequency................................................. 902-928 MHz (ASK)
Hopping channels................................................... 50 Channels
Channel spacing..................................................... 500 kHz or 200kHz
Hopping sequence.................................................. Pseudo random
Protocol language
EPC C0, C1 Gen 1 & 2, ISO Type B, EPC
V1.19 Rev.2
Read range ............................................................ Depends on type & size of labels used
Output power .......................................................... 1.0 Watt into 6 dBi antenna
Antenna configuration
..1 to 8 antennas
Stationary Reader (MPR-3014WF-xM-NA)
Operating temperature range ................................. -20° C to +65° C (-4° F to 149° F)
Color ....................................................................... Black
Output data formats ................................................ TCP/IP or Serial
GP I/O .................................................................... 4-input, 4-output
Peripheral Interface ................................................ Ethernet, Serial, USB
Dimension............................................................... 11 x 7.4 x 2.75 inches (28 x 19 x 7 cm)
Weight .................................................................... 2,172 g (4.78 lb)
Input voltage ........................................................... 12 VDC
Input current ........................................................... 12VDC 3.3 amp
2.1. CHANNEL FREQUENCY TABLE
Frequency range: 902 ~ 928 MHz
Minimum number of frequency channels: 50
CH
902~928
902.75
903.25
903.75
904.25
904.75
905.25
905.75
906.25
906.75
907.25
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
CH
10
11
12
13
14
15
16
17
18
19
902~928
907.75
908.25
908.75
909.25
909.75
910.25
910.75
911.25
911.75
912.25
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
CH
20
21
22
23
24
25
26
27
28
29
902~928
912.75
913.25
913.75
914.25
914.75
915.25
915.75
916.25
916.75
917.25
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
CH
30
31
32
33
34
35
36
37
38
39
902~928
917.75
918.25
918.75
919.25
919.75
920.25
920.75
921.25
921.75
922.25
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
CH
40
41
42
43
44
45
46
47
48
49
902~928
922.75
923.25
923.75
924.25
924.75
925.25
925.75
926.25
926.75
927.25
2.2. INPUT AND OUTPUT INTERFACES & CONNECTOR PIN ASSIGNMENT
AWID PROPRIETARY
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MPR-3014WF-xM
-8-
Doc# 041314
2.2.1. General Purpose Input/Output
Terminal block MPR-3014WF-xM 4 inputs & 4 outputs (optically isolated)
Pin #
Function description
Output 1
Output 2
Output 3
Output 4
Output Common
Pin #
10
Function description
Input Common
Input 4
Input 3
Input 2
Input 1
The four general-purpose inputs that use photo diodes are used to accept TTL input
commands. Each input requires 15 mA and 5V to activate. The four outputs are solid
state relays, with 0.03 uA off-state leakage current and the ability to sink 120 mA at a
breakdown voltage of 400V DC. All four outputs are protected with reverse clamping
diodes, and ready to drive inductive loads. The floating arrangement eliminates any
ground loop considerations.
2.2.2. RS-232
Pin#
Function description
DCD
RXD
TXD
DTR
Pin #
Function description
GND
DSR
RTS
CTS
2.3. MEASURING READ DISTANCE
Make sure you know the tag types. For instance, EPC tags must be pre-programmed to
be read. In certain readers and tags, the user must also be mindful of the tag s
orientation and the reader s antenna orientation, what mounting surface the tags are
designed for and how the tags are supposed to be mounted. Any departure from its
intended purpose will drastically affect the reader s ability to energize the tag and its
read range.
When measuring the reader s read range, make sure that the tag is properly oriented to
the reader antenna, and for optimum performance, be sure the operator s finger is not
within three (3) inches of the tag s antenna surface.
3. INSTALLATION PROCEDURE
This section provides installation and operation information for MPR-3014WF-xM readers.
3.1. PARTS LIST
AWID PROPRIETARY
MPR-3014WF-xM
-9-
Doc# 041314
Verify that all items listed below are present before starting the installation.
a. Sentinel-Sense MPR-3014WF-xM
b. ANT-915-CPS-A
c. RTC08/16/24
d. Documentation & Demo Program CD
e. 827-06W Reader mounting bracket (Optional)
f. 12 VDC wall plug power supply unit (AWID P/N PS12-3.3AR)
Qty=1
Qty=1~4 or 8
Qty=1~4 or 8
Qty=1
Qty=1
3.2. PREPARATION FOR INSTALLATION
3.2.1. Bench Top Verification
It is always a good idea to verify system operation before committing to a full-scale
installation. The following are the necessary steps to test reader s operation in a static
environment.
·
·
·
Connect reader to Network with a network cable at the TCP/IP port
Connect the power jack from the wall plug power supply to reader
Load the demo program CD onto (installation) PC and launch the demo program.
Try Connect after filling in the IP address of reader and then some commands.
3.2.2. Aiming of Antenna
Antenna Pattern for MPR-3014WF-xM
MPR-3014WF-xM comes with a set of (up to 4 or 8) antennas each circular polarized to
ensure reading tag with random orientation. Most circular polarized antenna has a
horizontal to vertical differential of up to 3 dB, this will cause the antenna pattern to
deviate from a true circle. AWID s antenna has a horizontal to vertical differential of
typically less than 0.5 dB, making the antenna pattern as near to a circle as possible.
Width ( W)
W (0.72R)
0.15
0.25
0.5
Distance (R)
0.75
Figure 1 MPR-3014WF Antenna Pattern
AWID PROPRIETARY
MPR-3014WF-xM
- 10 -
Doc# 041314
·
Antenna pattern measurements represent both horizontal and vertical polarized
planes of the read area transmitted by the reader.
·
In the drawing above, R = approximately 12 feet to 15 feet for MPR-3014WF-xM
antenna with Alien free space tags.
·
Antenna pattern can be affected by RFI and other environmental conditions.
3.3. INSTALLATION STEPS
·
·
·
Check to ensure that all connections are secure. Make sure all wires through the
cable clamps are anchored properly; avoid dangling wires that may become safety
hazard.
Mount the Reader using the four threaded mounting holes to fasten the reader on
the desired mounting surface. Connect antenna(s) to reader with antenna cable(s).
Mount or place antenna(s) at desired location(s). In cases where antenna aiming is
critical, please order antenna-mounting bracket (P/N 827-06W) from AWID. This
mounting bracket provides pan/tilt adjustment for the reader.
AWID PROPRIETARY
MPR-3014WF-xM
- 11 -
Doc# 041314
4. Notes on Software Programming and System Operation
4.1. SET UP AND SYSTEM OPERATION
4.1.1. Setting Up MPR-3014WF-xM
Power up with the 12-V power supply unit, connect to Network through the Ethernet port
with an RJ-45 cable.
4.1.2. Running a Custom Software Application or the AWID Demo Program
If AWID Demo Program is not used, it is expected user will launch a Custom Software
Application developed using the MPR 3014 Protocol and/or RFID Anywhere API to send
to reader the commands as specified.
4.1.3. Operating Modes
Typical operating modes for MPR-3014WF-xM can be grouped into the following modes:
Search Mode
This mode is used when operator or user is not certain which family of tags is placed on the
items to be tracked. Since most tags are deterministic in nature, the reader must cycle through
each and every protocol, issue a protocol specific inquiry, to hail and to wait for a response from
tags of that specific protocol. Therefore, if there are many different protocols, for an untrained
observer, the reader response will become sluggish.
Mixed Mode
This mode assumes the user is aware of the types of protocol in use, and furthermore, the
user made a determined effort to operate the reader in a mixed protocol mode. In this
mode, the user can decide how many and which specific protocols to be selected. Once
Mix Protocol Mode is selected, the reader will routinely cycle through each protocol, dwell
long enough for the reader to wait for a response and then move onto the next protocol. It
should be noted that in a mixed protocol mode, the tag must have sufficient time to
respond to the reader, and therefore, it can only be used on a conveyor belt arrangement,
with specific speed restrictions.
Single Protocol Mode
Single protocol is the normal mode of operation, where the protocol type is known and
many tags are expected to pass through the readers.
4.2. USERS NOTE
O FOR SYSTEM INTEGRATORS AND/OR SOFTWARE DEVELOPERS
System Integrators and/or Software developers should get familiar with RFID Anywhere
API and/or the MPR-3014 Protocol specifications for developing applications that control
MPR-3014 readers.
O FOR CUSTOM SYSTEM USERS
For custom system user, please refer to your host software user guide for information
regarding system and software operations
AWID PROPRIETARY
MPR-3014WF-xM
- 12 -
Doc# 041314
O FOR DEMO SOFTWARE USERS
If you are using the AWID demonstration software application which is .NET based with
easy-to-follow GUI operations, simply fill in the IP address of MPR-3014WF-xM installed
then click Connect should get you started.
5. Appendix
5.1. SAMPLE GPIO APPLICATION
Shown in diagram below is an example of applying such external devices as stack
lights, photo eyes, etc. to GPIO ports.
AWID PROPRIETARY

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Producer                        : PDFXC Library (version 2.5).
OS Info                         : vis: 148; ver: 5.1; bn: 00000a28; platf: 2; CDS: Service Pack 2
Create Date                     : 2006:07:28 19:26:01-08:00
Page Count                      : 12
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OGSR32EA031

Navigation menu