Aprilaire Humidifier 700 Users Manual 10008976A AA
700 to the manual 1b30034a-6aa8-4b2b-9595-5fd4a58526b5
2015-02-03
: Aprilaire Aprilaire-Humidifier-700-Users-Manual-467253 aprilaire-humidifier-700-users-manual-467253 aprilaire pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION ATTENTION INSTALLER: This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock. This product must be installed in compliance with all local, state and federal codes. Proper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices. MODEL 700 SERIES HUMIDIFIER WARNING CAUTION SPECIFICATIONS RISK OF PROPERTY AND EQUIPMENT DAMAGE. 1. ELECTRICAL SHOCK HAZARD. Disconnect electrical power to the furnace before starting installation. Failure to do so could result in serious injury from electrical shock. 1. Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home. 2. Do not install humidifier on the furnace jacket. 3. Do not install humidifier on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier. 4. Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home. 2. SHARP EDGES HAZARD. Sharp edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork. 3. RISK OF SCALDING. Water temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line. HUMIDIFIER DIMENSIONS Width 15 29⁄ 32” Height (including solenoid valve and drain spud) 18” Depth 10 11⁄ 32” 5. Do not connect the Model 700 or 700M power cord to multispeed furnace blower motors or blower motors other than 120 VAC. Premature component failure may result. Use Research Products Corporation Model 50 Current Sensing Relay. 6. When installing Humidifier Control on a downflow furnace, ensure blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Control. 7. Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction. 8. Do not install humidifier on the supply plenum where static pressure exceeds 0.4 in. wg. RECOMMENDED WIRING DIAGRAMS PLENUM OPENING 14 3⁄ 4”W x 14 5⁄ 16”H WATER FEED RATE 6 gph ELECTRICAL DATA 120 VAC-60 Hz, 0.8 AMP INSTALLATION OPTIONS (SEE STEP 6 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS) Typical Installation Model 700 DIGITAL HUMIDIFIER CONTROL Alternate Installation HOT WATER RETURN POWER R C INPUTS A B ODT W RETURN SUPPLY ADHC TERMINAL STRIP SUPPLY OUTPUTS G H H Gf NORTH, EAST OR WEST SIDE OF HOME OUTDOOR TEMPERATURE SENSOR FOR AUTOMATIC MODE 120 VAC OUTLET CONNECT DRAIN LINE HERE ABOVE EXPECTED SNOW LINE C C G G Y Y THERMOSTAT MANUAL CONTROL 90-921 BROWN WIRES 110 VAC W W Model 700M CONNECT TO HOT WATER SUPPLY R R 90-1514 FURNACE CONTINUOUSLY POWERED 24 VAC TRANSFORMER PROVIDED WITH HUMIDIFIER Orientation of Aprilaire Model 700 and 700M to Cooling Coils IMPORTANT USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED OFF THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE. BLANKED OFF END OF COIL • DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT. 24 VAC FURNACE ACCESSORY TERMINALS OR TRANSFORMER (10VA MINIMUM) SHUT-OFF (SADDLE VALVE) COMMON LO COOLING COILS IN WARM AIR PLENUM MODEL 50 CURRENT SENSING RELAY (IF REQUIRED) Aprilaire to be installed as shown in relation to cooling coils. IMPORTANT FURNACE BLOWER MOTOR WHEN MODEL 50 CURRENT SENSING RELAY IS USED: • WIRE MODEL 50 CURRENT SENSING RELAY INTO 24 VAC HUMIDIFIER CONTROL CIRCUIT ONLY! DO NOT INSTALL IN TRANSFORMER PRIMARY CIRCUIT. 120 VAC OUTLET CONNECT DRAIN LINE HERE 90-1208 BROWN WIRES RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357 1. Models 700 and 700M are not suitable for installation on ducts with horizontal airflow. Performance will be reduced. 2. When installing the Aprilaire humidifier with the Aprilaire Digital Humidifier Control or on a heat pump system, use hot water. The heated water supplements the reduced supply air temperature as added heat for evaporation. WATER SUPPLY HI NOTES 90-922 – TOP – READ REVERSE SIDE FIRST! READ REVERSE SIDE FIRST! READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION FURNISHED ITEMS Figure 1 Figure 2 Figure 3 Figure 4 24 VAC Transformer Digital Humidifier Control (Model 700 only) Manual Humidifier Control (Model 700M only) Humidifier Control Installation Instructions Saddle Valve Humidifier Installation Template ITEMS NOT FURNISHED Mounting screws (sheet metal screws) Water supply line (1 ⁄ 4” copper) Drain line (1 ⁄ 2” I.D. hose) Low voltage wire Model 50 Current Sensing Relay (if required) 1. Detach the cover assembly by lifting the latch at the bottom. Remove the Water Panel® evaporator assembly by grasping at top and tipping out. See Figure 1. 2. Position template on supply plenum. Make sure template is level. Allow clearance for drain line and for servicing. See “Installation Options” on opposite side for position relative to cooling coil. 90-923 90-924 90-925 5. Insert Water Panel Evaporator Trace template outline. Cut 14-3/4” wide x 14-5/16” high opening. Avoid injury from sharp edges. assembly into base. Make sure bottom of scale control insert (5) is over drain opening. Snap top of evaporator assembly into base. 3. Position base (2) in duct opening top-first so hooks engage sheet metal at top. See Figure 2. Insert bottom of base and slide down to engage hooks at bottom. 6. Control installation and wiring. Disconnect electrical power to furnace before wiring control. In order for humidifier to operate, furnace must be on and RH must be below set-point of control. Wiring diagrams illustrate recommended method of detecting furnace operation. 4. Rotate swing locks to secure base to duct. See Figure 3. Fasten base to duct using 4 sheet metal screws in holes provided. PARTS LIST 1. Front Cover 2. Base 3. Orifice Plate 4. Motor Mount Bridge 5. Scale Control Insert 6. Water Panel Evaporator 7. Water Distribution Tray 8. Fan Blade 9. Motor 16 15 6 3 2 Manual Control can be mounted in return duct or on wall in living space. Knob and cover must be removed to mount control. See wiring diagram for 24V control connections. • For return duct mounting, position template in convenient location on duct. Avoid injury from sharp edges when cutting opening. Make sure foam gasket is in place and secure control to duct using 2 screws in holes provided. • For wall-mount, select location that will not be affected by drafts or heat sources. Remove and discard foam gasket and secure control over wire access opening using screws & anchors provided. 7 17 MANUAL HUMIDIFIER CONTROL, MODEL 700M: 10. Motor Mount Gasket 11. Control Relay 12. Power Cord 13. Strain Relief Bushing 14. Solenoid Valve 15. Connector Plug 16. Feed Tube 17. Nozzle 18. Relay Connector Plug DIGITAL HUMIDIFIER CONTROL, MODEL 700: • Select location for control on return duct. Drill 3/4” hole for sensor. Knob and cover must be removed to mount control. Place control on duct with RH sensor extending into duct opening. Make sure gasket is in place around sensor cage. Secure control to duct using 2 screws in openings provided. 8 5 4 18 14 • See wiring diagrams on template and control instructions for 24 V control connections. 10 9 13 12 7. Humidifier will function with cold, hot, softened or unsoftened water. Hot water (140°F max) is strongly recommended to provide maximum evaporative capacity. Saddle valve provided may be used to tap into water supply. See installation instructions on saddle valve package. Saddle valve is designed to be fully opened or closed. Do not use to regulate flow. 8. Run 1/4” copper tubing from saddle valve to solenoid valve. DOUBLE-WRENCH TO PREVENT LEAKING. See Figure 4. 9. INSTALL DRAIN IN ACCORDANCE WITH LOCAL CODES. Run 1/2” I.D. hose from drain spud to floor drain. Make sure drain has constant downward slope and is not kinked. Do not overtighten hose clamp onto drain spud. Do not use solvent adhesive on drain spud. 10. Check humidifier operation. Open saddle valve and turn control to highest setting. Turn on furnace. Allow humidifier to run until water flows from drain. Make sure all electrical connections are secure and all plumbing connections are water-tight. Set control to proper setting. NOTE: BEFORE LEAVING THE JOB SITE, MAKE SURE: 1. Saddle valve is fully open. 2. All plumbing connections are watertight. 3. Humidifier functions properly. 11 1 TEMPLATE MUST BE LEVEL 90-926 90-1244 IMPORTANT! Be sure owner’s manual containing instructions for operation and warranty information is given to owner in order to avoid unnecessary calls. Warranty is void unless humidifier is installed by qualified heating and air conditioning contractor due to possible misapplication of product. 10008976 B2205118A 4.10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 X Press Private : %%DocumentCustomColors: (PANTONE 2955 U).%%DocumentProcessColors: Cyan Magenta Yellow Black.%%QRKLabCustomColor: .354 .48 .412 (PANTONE 2955 U).%%RGBCustomColor: .153 .267 .397 (PANTONE 2955 U).%%EndComments Creator : QuarkXPress(R) 7.31 Create Date : 2010:04:27 09:29:08 Producer : QuarkXPress(R) 7.31 Modify Date : 2010:04:27 09:29:08 Title : 10008976A AA 700 TemplateEXIF Metadata provided by EXIF.tools