Aram Huvis APSII PORTABLE SKIN/HAIR DIAGNOSIS SYSTEM User Manual Microsoft PowerPoint APSII 100 x

Aram Huvis Co., Ltd. PORTABLE SKIN/HAIR DIAGNOSIS SYSTEM Microsoft PowerPoint APSII 100 x

User Manual

Download: Aram Huvis APSII PORTABLE SKIN/HAIR DIAGNOSIS SYSTEM User Manual Microsoft PowerPoint   APSII 100 x
Mirror Download [FCC.gov]Aram Huvis APSII PORTABLE SKIN/HAIR DIAGNOSIS SYSTEM User Manual Microsoft PowerPoint   APSII 100 x
Document ID1872450
Application IDCp+UDHMb/vg5PNN9OOKvBQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize188.38kB (2354710 bits)
Date Submitted2013-01-02 00:00:00
Date Available2013-01-02 00:00:00
Creation Date2012-11-21 18:38:23
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2012-12-26 14:04:44
Document TitleMicrosoft PowerPoint - APSII-100 USER MANUAL.pptx
Document CreatorPScript5.dll Version 5.2.2
Document Author: KCW

Aramo Professional Scanner II
APSII
User’s Manual
Aramo Professional Scanner
SKIN DIAGNOSIS SYSEM
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference. and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications (including the antenna) made to this device that are not
expressly approved by the manufacturer may void the user’s authority to operate the
equipment.
To comply with FCC RF exposure compliance requirements, a separation distance of at least
20 cm must be maintained between the antenna of this device and all persons. This device
must not be co-located or operation in conjunction with any other antenna or transmitter.
This equipment complies with FCC
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
ramo
ramoSmart
AA
Professional
NavigatorII‐100
Scanner II
Content
1. How to use
2. How to operate
•
System setting
•
Wireless & network setting
3. How to diagnosis
•
Full mode
•
View mode
4. How to set
5. Additional information
•
Standard & Features
•
Troubleshooting Guide & FAQ
•
CAUTION UPON INSTALL & USE
Use the touch screen
How to use
The touch screen lets you select items or perform function. Learn basic
actions to use touch screen.
• Tap : Touch once with your finger to select or launch the menu option, or
application
• Drag : Tap and drag your finger up, down, left, or right to move to items on lists.
• Tap and hold : Tap an item and hold it for more than 2 seconds to open pop-up
option list
• Double-tap : Tap twice quickly with your finger to zoom in or out while viewing
photos.
Enter text
Enter text by selecting characters on the virtual keypads
①
②
⑤
②
⑤
③
⑥
③
⑥
④
④
No.
Function
①
Shortcuts for frequent use
②
Capitals lock key
③
Switch between ABC and Number(symbol) mode
④
Space
⑤
Delete
⑥
Start new line
Icons to operate in Manual
How to use
Icons
To do
Touch to take images from the device
Go to capturing page
OK
Cancel
USE
Analysis
3D
OK
Go back to previous page
Use the image taken for diagnosis
Analyze the image
3D Image
Go back to previous page on skin image
Mode
Note
Change the lighting mode
* Touch the “>” or fling the screen to go to next page.
* Tap the screen to focus.
Turn on / off & System main page
* Tap in red box
How to operate_ Turn on/off
- On/Off button: Press and hold for 3 seconds
- “Sleep” mode on / off : Press the button
Turning on…
Go to “setup” page
Turning off…
Go back to system main page
Icons
To do
Icons
To do
Diagnosis application
Alarm
Gallery (album)
Add alarm
MP3
Internet
System setting
How to set the system
* Tap in red box
How to operate_ System setting
≫ Application setting
Check the “√” mark.
The setting have to be a
ctivated to download ap
plication.
≫ Brightness setting
Adjust the Brightness to display the application
more effectively.
How to set the system
* Tap in red box
How to operate_ System setting
≫ Language setting
 Keyboard language
②
①
Deactivate
Select the language you
want to use
Changed the keyboard
language
How to set the system
* Tap in red box
How to operate_ System setting
≫ Language setting
 How to change the keyboard language
Press and hold the “space-bar” to show the language
selection
Drag left or right to choose
the language
 How to change the System language
Select the language you want
to use
How to set the system
* Tap in red box
How to operate_ System setting
≫ Date & Time setting
 How to set date
Enter the current date
 How to set time zone & time
Select user’s time zone or
city name
Enter the current time
How to set the system
How to operate_ System setting
≫ Wi-Fi connection
①
Tap “setup”.
②
On System main page
Check the Wi-Fi mark
Find and connect the available Wi-Fi
* Tap in red box
How to set the system
* Tap in red box
How to operate_ System setting
≫ Bluetooth Pairing
 How to pair the diagnosis system with the host device
Note
* Host device : all kinds of PC including tablet PC you want to send the
diagnosed result or the related images.
Check the name of host device
Activate the Bluetooth function
on host device for the diagnosis
system to search and pair with
host device.
← Example image
On host device
Accept the paring request sent
from diagnosis system.
Password: 0 (number)
Scan for host device
Select the host device
Check the Bluetooth mark
Check the pairing status
How to set the system
How to operate_ System setting
≫ Bluetooth Pairing
 How to change the name of diagnosis system
Enter the device name
what you want
* Tap in red box
Diagnosis Process ≫ How to setup
* Tap in red box
How to operate_ setting
Tap “setup”.
≫ Language
≫ Option
Drag
* Show measurement page before
starting diagnosis.
- Green: activate status
- Gray: deactivate status
Select the language
≫ Measurement
Green : activate → Analyze
Gray : deactivate → Do not analyze
Select what you want to diagnose
* Show the diagnosed result
by number on the capture page.
Diagnosis Process ≫ How to setup
* Tap in red box
How to operate_ setting
Tap “setup”.
≫ Language
≫ Option
Drag
* Show measurement page before
starting diagnosis.
- Green: activate status
- Gray: deactivate status
Select the language
≫ Measurement
Green : activate → Analyze
Gray : deactivate → Do not analyze
Select what you want to diagnose
* Show the diagnosed result
by number on the capture page.
Diagnosis Process ≫ How to setup
≫ Advance
≫ Network
How to operate_ setting
Selected status
Unselected status
Check the version of
application
Set Wireless connection; Wi-Fi or Bluetooth
≫ Email
Enter the ID (ex. abcd1234)
Enter the Domain (ex. @gmail.com)
Enter the Password (ex. aaaa1234)
Register the sender’s email account
* Tap in red box
Diagnosis Process ≫ Full mode
* Tap in red box
≫ Start diagnosis
How to diagnose_ Full mode
Note
* Gray : deactivate status
* Black : activate status
Enter age group and gender
of customer
≫ Hydration & Elasticity
Place the sensor onto your skin and tap
Note
* Do NOT move during the measurement.
* “Please, rescan…” : To measure again by taping
Diagnosis Process ≫ Full mode
* Tap in red box
≫ Sebum ( T & U zone)
How to diagnose_ Full mode
Put the below sebum tape (pink area) onto the U or T-zone of your face for 3 seconds.
→ How to hold the sebum paper
T - ZONE
How to put the sebum paper on T-zone
U - ZONE
How to put the sebum paper on U-zone
Diagnosis Process ≫ Full mode
≫ Sebum ( T & U zone)
How to diagnose_ Full mode
Tap
Tap each image to magnify
Analysis
Tap
Note
to go back to “Sebum-U/T” page.
* Touch the “>” or fling the screen to go to next page.
* Tap the screen to focus.
* Take the image without any white blank.
* Tap in red box
Diagnosis Process ≫ Full mode
≫ Pore
How to diagnose_ Full mode
Tap.
Analysis
Drag
Tap
3D
Note
3D image
* Touch the “>” or fling the screen to go to next page.
* Tap the screen to focus.
* Tap in red box
Diagnosis Process ≫ Full mode
* Tap in red box
≫ Melanin
How to diagnose_ Full mode
Tap.
Analysis
≫ Sensitivity
Tap.
Analysis
≫ Wrinkle
Choose the area by moving
the white box
Note
Tap.
* Touch the “>” or fling the screen to go to next page.
* Tap the screen to focus.
Analysis
Diagnosis Process ≫ Full mode
≫ Wrinkle
How to diagnose_ Full mode
Tap
3D
3D image
≫ Acne
Tap
Note
Analysis
* Touch the “>” or fling the screen to go to next page.
* Tap the screen to focus.
* Tap in red box
Diagnosis Process ≫ Full mode
≫ Analysis result
How to diagnose_ Full mode
Note
* Product recommendation : to be updated
* Tap in red box
Diagnosis Process ≫ Full mode
* Tap in red box
≫ Send
How to diagnose_ Full mode
Enter the customer’s email address.
Turn to USB storage…
Recognized as a Removabl
e disk on PC
Note
* Bluetooth : to be updated
Diagnosis Process ≫ View mode
* Tap in red box
≫ NL mode (for Wrinkle)
How to diagnose_ View mode
Tap Mode to change
the lighting mode.
Choose the area by moving
the white box
Turn to USB storage…
3D image
≫ PL mode (for Melanin)
Tap
Mode
Note
to change the lighting mode.
* Touch the “>” or fling the screen to go to next page.
* Tap the screen to focus.
Diagnosis Process ≫ View mode
* Tap in red box
≫ UV mode (for Acne)
How to diagnose_ View mode
Tap
Mode
UV
Note
to change the lighting mode.
UV
UV
* Touch the “>” or fling the screen to go to next page.
* Tap the screen to focus.
How to update the application
Note
* Tap in red box
* Check the Wi-Fi connection before updating
How to set the APSII
②
②
①
①
Drag down
How to remove the application
How to set the APSII
On System main page
Find “Smartnavi” application.
* Tap in red box
How to re-install the application after
removing
* Tap in red box
How to set the APSII
Drag down
②
①
On System main page
Enter the address below and
download the application
www.aramhuvis.com/data/asn2/smartnavi.apk
Standard & Features
Section
Item
Contents
Optical/Camera Camera
5M pixel CMOS
Sensor
X30,X60 TPL
Additional information
HW
AF
VCM
Sensor
Hydration
Light
Normal, Polarize, UV‐[3CH]
CPU
S5PV210 ARM‐CORTEX A8 [1GHz]
Memory
DDR2 SDRAM (512MB) / NAND FLASH (512MB)
SD Memory
T‐Flash (Micro SD)
LCD
2.2Inch TFT LCD QVGA (240*320)
Touch
R‐TOUCH
Wi‐Fi
Wireless 802.11b/g/n (Wi‐Fi Direct Avail)
Bluetooth
BT ver3.0+HS
Audio
AC97 , Codec (WM1800)
SPEAKER
Max 1.0 W, Internal Speaker
USB
USB 2.0 HOST/DEVICE
Battery
Li‐ion (1150mAh)
Adaptor
AC Adaptor DC 5V / 2000mA
Key Pad
Power , 4-direction navi Key ,Left , Right
Microphone
Internal MIC
Storage
Micro SD ver2.0 (2GB)
Weight
127g (with battery)
Dimension (mm) 57(W) x 116(H) x 18 (D)
SW
Bootloader
u‐boot‐1.3.2
OS
Android Gingerbread 2.3
Media
MPEG4(SP/ASP)/H.263(Profile3)/H.264(BP/MP/HP)
Applications
Google app.
Debugging Port USB Client/UART
Troubleshooting Guide & FAQ
I cannot turn on the device.
• Connect and charge the device (or the battery) using the adaptor provided the supplier.
(The battery charging indicator will be shown on the system main page.)
Additional information
I cannot power on the device even the battery is still full.
• The battery might be dislocated on the device. Please separate the battery from the de
vice and put it on, and then power on again.
The battery is not charging very well.
• Separate the battery from the device and put it on again.
• Check the connection among a device, a battery, and a charger.
• A battery cannot be charged if there is an alien substance on the charging port. In this
case, please use the device after cleaning the charging port of the device or check whe
ther the sticker is attached on charging port.
The using time of the battery is different from the manual.
• The battery using time will be shorten if you put the charged battery in a low or high t
emperature.
• The battery using time vary in service type, using environment, using period of the batt
ery.
• The battery is consumed without using the device, and the battery using time will be s
horten if you use additional functions of the device.
The device turns on but the diagnosis doesn’t work.
• Check the smart card is correctly inserted (SD card slot on the button of the device).
There are dust on the device.
• Clean the dust by using a smooth fabric. Do not use benzene, alcohol, and a synthetic d
etergent.
The screen is frozen and the keys not working when using the device.
• Separate the battery from the device and put it on again.
If the device is still not working, please contact to the customer service center.
A "force close" message appears on the screen.
• The repetition of commands can trigger a bug. Sometimes there may be a brief delay
before the command is completed. Do not repeat/multiply the tasks as the device will
no longer be able to follow them.
Troubleshooting & FAQ
I cannot connect to Wi-Fi.
• Check the connection status on setting page.
• Try to connect to another Wi-Fi.
• - Bluetooth : Check the pairing status and try to re-pair the device with host device.
Additional information
I cannot connect to Blue-tooth.
• Make sure to use the Bluetooth hosting devices that have Bluetooth certified with the
logo. You may need an external Bluetooth dongle for those devices that do not have
Bluetooth feature.
• Bring the device to closer with the Bluetooth hosting device.
• Try to re-pair the device with host device.
• The password of pairing is “0”(number).
The touchscreen doesn’t react to my finger commands.
• Before using for the first time remove the protective plastic film.
• Use the stylus-pen provided from supplier.
The screen was turned off.
• The device has a power save function that turns the screen OFF after 1 minute. Press
the on/off button to turn on the screen.
I can see the black screen only during measurement.
• Check the LED light inside lens on the head part when you try to measurement. If you
cannot see the light, please connect the customer service center.
The image is not clear.
• Tap the screen while capturing to focus.
I cannot update the diagnosis application.
• Check the network connection, the update process can be done after connect to Wi-Fi.
CAUTION UPON INSTALL & USE
Thanks for using the product of Aram HUVIS Co., Ltd.. The product undergoes strict quality
management and inspection process before production and introduction to market. Product defect or
trouble during warranty period is entitled to free repair.
Additional information
Model
Serial No.
Date of Purchase
Customer Name
Place of Purchase
Contact
Information
Please, fill out warranty and keep it with receipt to enjoy better service in the future.
▶ Warranty Period
14 MONTHS from the products arrival.
▶ Service Free of Charge
Service is provided free of charge only if product defect occurs within 1 year from the date of
purchase (within Warranty Period).
Case
Service
Within Warranty Period
Functional or operational defect which occurs
under normal condition of use within 10 days
after purchase
Product replacement
Functional or operational defect which occurs
under normal condition of use within 14 year
after purchase
Free of charge
Defect which results from the mistreatment
by the user
Partial free repair Or
Repair with charge
After Warranty Period
Repair with charge
▶ Repair with Charge
* Cases except for product defect
If service is requested due to the reasons except for defect, service fee may be charged.
- Defect resulting from the mistreatment by the user
- Defect resulting from the lack of caution (leakage or shock) or unauthorized repair or remodeling
- Defect due to natural disasters such as fire, earthquake or flood
CAUTION UPON INSTALL & USE
1. Humidity
Do not install the product in the place with rain leakage or of high humidity. If the product is
leaking, it may cause damage or fire.
2. Repair
Additional information
Do not disassemble or remodel the product because it may cause danger such as an electric shock.
When a problem occurs, do not attempt to repair it. Instead, contact the seller.
3. Electricity
Do not use electricity except for what is prescribed here. Using improper electricity may cause an
electric shock or danger.
4. Installation Environment
Do not install the product in a too hot or cold place. (Recommended Temperature : 15℃ ~ 35℃ )
5. Sunlight
Do not expose the camera of the product to the sun or a direct ray of light. It may cause product
damage
6. Shock or Vibration
Do not drop the product or give it a strong shock or vibration.
7. If the product does not work properly
If a problem occurs while using the product (unidentified noise, smell or smoke), stop using it and
turn the power off and contact the seller.
8. Dirt on Lens
Make sure that keep camera lenses clean and away from pollution. If it polluted by finger print or
external dirt, cleanse it with cotton stick socked with 70% Ethyl Alcohol solution or use air blower
to remove the dust. Those products are available at camera shop.
9. For After-Service
When any of the following occurs, turn the power off and have the product repaired at the place of
purchase.
i.
Power Connector is damaged
ii.
The product is leaking
iii.
Liquid is spilt over the product or it has alien substance.
iv.
Product does not work as indicated in this manual.
(Attempting to operate the product against manual may cause more serious damage.)
v.
Product is dropped to the floor and seriously damaged.
ramo
ramoSmart
AA
Professional
NavigatorII‐100
Scanner II
World leader of skin & hair diagnosis system
Rm.801 Byucksan Technopia, #434-6 Sangdaewon-dong, Jungwon-gu, Seongnam-city, Gyeonggi-do, KOREA 462-716
TEL [82-31] 732.6320 FAX [82-31] 732.6330 E-MAIL info@aramhuvis.com WEBSITE www.aramhuvis.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Format                          : application/pdf
Creator                         : KCW
Title                           : Microsoft PowerPoint - APSII-100 USER MANUAL.pptx
Create Date                     : 2012:11:21 18:38:23+09:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2012:12:26 14:04:44+09:00
Metadata Date                   : 2012:12:26 14:04:44+09:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:d3d0f967-ac73-4085-941b-801d202a2fb0
Instance ID                     : uuid:4ed53f0b-9dbe-4c41-8354-068092cdb952
Has XFA                         : No
Page Count                      : 35
Author                          : KCW
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XYCAPSII

Navigation menu