      User’s Manua Data Collector PI-XXXX, AP-XXXX,SP-XXXX,PE-XX   (X=0-9 , A-Z , a-z , dash , or blank)
 i  Regulatory Compliance FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This  equipment  has  been  tested  and  found  to  comply  with  the limits  for a Class  B  digital device, pursuant  to  part  15  of  the  FCC Rules. These limits are designed to provide reasonable protection against  harmful  interference  in  a  residential  installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may  cause  harmful  interference  to  radio  communications. However, there is no guarantee that interference will not occur in a  particular  installation.  If  this  equipment  does  cause  harmful interference  to  radio  or  television  reception,  which  can  be determined  by  turning  the  equipment  off  and  on,  the  user  is encouraged to  try to  correct the  interference  by  one  or  more  of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/ TV technician for help.
 ii   CAUTION: Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment.  RF exposure warning    The equipment complies with FCC RF exposure limits set forth for an uncontrolled environment. The equipment must not be co-located or operating in conjunction with any other antenna or transmitter.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
 iii  To ensure that RF exposure levels remain at or below the tested levels, use a belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5mm between the device and the body.  The FCC has granted an Equipment Authorization for this device with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. SAR information on this device is on file with the FCC and can be found under the Display Grant section of www.fcc.gov/eot/ea/fccid after searching on FCCID:NBF-PI-1X30     RF Exposure Information (SAR)  This device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government.  The exposure standard employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. Tests for SAR are conducted using standard operating positions accepted by the FCC with the EUT transmitting at the specified power level in different channels.
 iv   CAUTION: EXPLOSION HAZARD Do not disassemble, short circuit, heat the battery or dispose of in fire. Store battery pack in a proper place. Do not expose to temperature above 60℃/140℉. Use specified charger only. Please dispose of the used batteries following the rules or laws issued by the local government.   警告:電池若未妥善處理,可能會導致爆炸。   請勿拆卸電池,或用火銷毀電池。請將電池放置於兒童拿不到的地方。 請使用專用充電器充電,並請依照當地政府或法律規定妥善處理廢棄 電池。  經型式認證合格之低功率射頻電機,  非經許可,公司,  商號或使用者 均不得擅自變更頻率,加大功率或變更原設計之特性及功能 低功率射頻電機之使用不得影響飛航影響安全及干擾合法通信,  經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續 使用前項合法通信,指一電信法規定作業之無線電通信低功率射頻電 機需忍受合法通信或工業,科學及醫療用電波輻射性電機設備之干擾
 i   Release Note  Version Date Note V1.0 02/22 2017 Initial release
 ii  Content 1  Introduction .......................................................................... 1 1.1  Unpacking ................................................................. 2 1.2  Understand your terminal ........................................ 4 1.2.1  Terminal ........................................................ 4 1.2.2  Holder(Option) .............................................. 5 1.3  Indicators .................................................................. 6 1.3.1  LED ................................................................ 6 1.3.2  Buzzer ............................................................ 8 1.3.3  Vibration ....................................................... 8 1.4  Keypad ...................................................................... 9 1.5  Power source .......................................................... 14 1.5.1  Inserting or replacing battery ..................... 15 1.5.2  Charge the battery ...................................... 18 2  Get started .......................................................................... 20 2.1  Set up your terminal ............................................... 20 2.2  User interface ......................................................... 21 2.3  Connection ............................................................. 23 2.3.1 Remote link connection .......................................... 24 2.4  Attach the hand strap ............................................. 27 3  Controls and settings .......................................................... 29 3.1  User Menu .............................................................. 29 3.1.1  Run Program ............................................... 30 3.1.2  Remote Link ................................................ 30 3.1.3  Scanner(HID) ............................................... 31
 iii  3.1.4  Information ................................................. 32 3.2  System Menu .......................................................... 33 3.2.1  Remote Link ................................................ 33 3.2.2  Disk info ...................................................... 33 3.2.3  Timer setting ............................................... 34 3.2.4  Environment ............................................... 35 3.2.5  Test .............................................................. 36 3.2.6  System info .................................................. 38 3.3  Supervisor Menu .................................................... 39 3.3.1  Remote Link ................................................ 40 3.3.2  Format disk ................................................. 43 3.3.3  Setting ......................................................... 44 3.3.4  Information ................................................. 49 4  Applications ........................................................................ 50 5  Troubleshooting.................................................................. 51 5.1  Hardware issues ...................................................... 51 5.2  Communication issues ............................................ 52 5.3  Barcode scanning issues ......................................... 53 6  Specifications ...................................................................... 54 Appendix A .............................................................................. 58
   1  1 Introduction PI series is a lightweight, portable data terminal (PDT) for data capture and collection. This manual will help you to get to know PI series and utilize it well. Features ■ Scratch-resistant keypad  Coated with PC (polycarbonate), the letters and numbers on the keys won’t wear off between uses. ■ Battery cover open detection  When the switch of the battery cover is up, the system automatically saves your files and shut down. ■ Large flash memory  PI series offers more flash memory than the rivals on the same level. The standard is 20 MB, and the optional is 60 MB. ■ Wi-Fi connectivity  You can exchange data over a Wi-Fi network.(PI-1030) ■ Backup battery  The backup battery gives you additional 15 minutes to finish your job if the primary batteries wear out.
  2  1.1 Unpacking Make sure all of the following items are included in your package. PI series  Quick Start Guide    USB Cable       or RS-232 Cable with USB power cord     Holder(Option)  Hand Strap
  3     Plug and Power Supply (Option)      When you receive your terminal, open the package immediately and inspect for shipping damage. If you discover any damage, contact the shipping company and file a claim. Argox is not responsible for any damage incurred during shipping. Save all package materials for the shipping company to inspect.   Note  If any item is missing, please contact your local dealer.
  4  1.2 Understand your terminal 1.2.1 Terminal Left Front Right Back     Top Bottom    1 LED Three LEDs. 2 LCD Display A mono LCD. 3 Keypad A 25-key keypad. 4 Battery Cover The battery cover. 5 Battery Cover Switch Open and close the battery cover. 6 Reading Window The bar code reading beam is emitted through this window. 7 Speaker Buzzer sound 1 2 3 6 8 5 4 7
  5  8 Connector A port to connect computer 1.2.2 Holder(Option) The holder is used to hold your terminal in its standing position.  In the bottom of holder, make sure cable wire is installed as below.
  6  1.3 Indicators PI series has three LEDs and a buzzer to indicate its current status.       1.3.1 LED Your terminal has three LEDs on the upper-left corner. They have different behavior. The table below gives information about the status they indicate.   LED Color Scan LED Green, Red and Orange BT or Wi-Fi LED Blue BT or Wi-Fi LED Charger LED Scan LED
  7  Charger LED Red  LED Behavior Status Note Scan LED Solid green User defined Use SDK. Solid red User defined. Use SDK. Solid orange User defined. Use SDK. Flashing green Transmitting data or user defined. Use SDK. Flashing red User defined. Use SDK. Flashing orange User defined. Use SDK. Off No data transmission or user defined. Use SDK. BT & Wi-Fi LED Solid blue Your terminal is connected through Bluetooth or Wi-Fi.  Flashing blue Your terminal is ready to be connected through Bluetooth or Wi-Fi.  Off Bluetooth or Wi-Fi is turned off. Default Charger LED Solid red Your terminal is fully charged or connected to a power source. Controlled by hardware. Flashing red Charging. Controlled
  8  LED Behavior Status Note by hardware. Off Your terminal is not connected to any power source. Controlled by hardware. 1.3.2 Buzzer You can define the status the vibration indicates using the SDK. Sound Status 1 Short Beep A key is pressed. A good scan. An error occurred. 2 Short Beep The battery is low. 4 Short Beep Battery is too low to turn off terminal. 1.3.3 Vibration You can define the status the vibration indicates using the SDK. Vibration Status Vibrate A good scan.
  9  1.4 Keypad     Scan key    Cursor keys    Control keys    Numeric keys    User-defined keys    Power key Scan key Scan a bar code.  Cursor keys Up Move the highlight bar up. Fn+Up Open Message Menu. Down Move the highlight bar down. Fn+Down Adjust the backlight brightness. The brightness repeats the sequence 0123. Left Move the highlight bar to the top. Fn+Left Reduce the volume. Right Move the highlight bar to the bottom
  10  Cursor keys Fn+Right Increase the volume.  Control keys ESC The Escape key. 1. Go up one level in a menu. 2. Give up changing a setting. 3. Exit a program. Fn The Function key. Use with other keys. Ex: “Fn+Down Arrow” is to adjust the backlight brightness. The function of F0 - F9 (Fn+0 - 9) can be defined using an SDK. ENT The Enter key. 1. Enter a menu. 2. Select an option. BS The Backspace key. 1. Delete a character to the left of the cursor.   Numeric keys You can use the keypad to enter numbers or English characters, depending on the mode you’re using. 1 1. Enter the number one. 2. Enter these signs: plus (+), minus (-), star (*) and slash (/). 2 1. Enter the number two. 2. Enter the letters A, B, C.
  11  Numeric keys 3 1. Enter the number three. 2. Enter the letters D, E, F. 4 1. Enter the number four. 2. Enter the letters G, H, I. 5 1. Enter the number five. 2. Enter the letters J, K, L. 6 1. Enter the number six. 2. Enter the letters M, N, O. 7 1. Enter the number seven. 2. Enter the letters P, Q, R, S. 8 1. Enter the number eight. 2. Enter the letters T, U, V. 9 1. Enter the number nine. 2. Enter the letters W, X, Y, Z. 0 1. Enter the number zero. 2. Enter these characters: space ( ), at (@), comma (,) and semicolon (;). Alpha Switch the input method between numbers, uppercase and lowercase characters. . 1. Enter a period (.). 2. Enter these symbols: dollar sign ($), percent sign (%), ampersand (&) and number sign (#).
  12    User-defined keys P1 User-defined key. P2 User-defined key. P3 User-defined key.  Power key Turn on or turn off your terminal.  Power combination key You can use the key combinations to enter different menus or modes. Press and hold the combination of keys, until your terminal responds. 3 + 9 + Power System Menu. 1 + 3 + 0 + Power Supervisor Menu. 1 + 3 + Power Force mode. P1 + P2 + P3 + Power BIOS reset. SCAN + Power Warm reset. SCAN + Power (5 sec) Cold reset. You need to press the keys for 5 seconds.
  13    ■ System Menu  Enter System Menu. ■ Supervisor Menu  Enter Supervisor Menu. ■ Force mode  It updates all firmware files and restores all system parameters to factory settings. This mode needs to be used with an SDK or computer software. You can use this mode when you encounter the problem that can’t be resolved in any other way. ■ BIOS reset  it is the same as BIOS default (see Supervisor Menu). It resets all your terminal settings, including the password of Supervisor Menu. ■ Warm reset  It restarts your terminal without changing any settings. You can use it when your program stops responding. ■ Cold reset  It forces your terminal to restart. The data stored in the DRAM may be removed. You can use it when your terminal crashes, or when you can’t turn on your terminal by pressing the Power key.
  14  1.5 Power source There are three ways to supply power to PI series: 1. Two AA batteries. Recommended alkaline rechargeable type. 2. Use the USB cable with computer. 3. Use the power supply with the USB or RS-232 cable. Cable Type Charge your batteries Supply power without batteries Need to use with a power supply USB Yes Yes No RS-232 No No Yes       Warn  Do not collect data while plug the connector. It could cause damage to RS-232 and USB port function.   Note  It’s not necessary to use a USB cable with the power supply, but the battery charging time is shorter with it.
  15  1.5.1 Inserting or replacing battery   When you see the battery icon shows low. You need to change new battery or charge It immediately. If there is no power, the back up battery can hold the data about 15 minutes. Therefore, always upload your important data after work or keep two AA batteries in case.     Caution   Do not mix old batteries and new batteries or standard (carbon-zinc) with alkaline batteries. Remove batteries if product is not to be used with for a long time. Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.   DO NOT RECHARGE DIFFERENT TYPES OF BATTERIES.  1. Press and slide two release latch at the same time to open the battery cover.
  16  2. Inserting two batteries as indicated inside battery compartment.  3. Close the battery cover as follow.      ① ② +  -          -      +
  17  4. Make sure cover is closed and slide two latch back.
  18  1.5.2 Charge the battery If you’re using rechargeable batteries to supply power to your terminal, you can charge them by (1) connecting the USB cable to your terminal and computer. (2) Using a battery charger to charge batteries in advance. (3) Connecting the USB cable to your terminal and use a power supply. When your batteries are fully charged, the Charger LED turns to solid red.   Important  To protect power source, PI series can not be powered on unless battery cover back are closed correctly.   Charging by Full Charge Time Power Supply 5-6 hours USB Cable 7-8 hours  Important  Before using PI series, we recommend to charge PT-10 series 1 day to make sure backup battery is fully charged.
  19     Note   The triangle mark should be face up when you want to plug connecter in to PI series.
  20  2 Get started This chapter provides information about how to work with your terminal and make connection to computer.  2.1 Set up your terminal 1. Choose one to power on your terminal  Open the battery cover and Install two AA batteries.  Connect your terminal to your computer using USB or RS-232 cable with adapter. 2. Press the Power key to turn on your terminal.  Power key
  21  2.2 User interface      Item Description Menu Current menu title Options Items in the menu. Status bar It displays the information about your terminal. Input method The way you enter data. You can enter numbers, lowercase or uppercase characters. Time The current time. Menu Options Input method Time Power source Wireless   Status bar
  22  Item Description Wireless communication When you open Bluetooth or Wi-Fi function, it displays an icon without waves. If connection is successful, the icon will show waves. Power source If your terminal is connected to a direct power supply (USB or RS-232), it displays a plug icon; if it is running on batteries, it displays a battery icon.
  23  2.3 Connection PI series have four interfaces to connect: USB, RS232, Bluetooth and WI-FI. Each one can choose two ways as below.  Remote link: It is a unique protocol from Argox development. Visit Argox website below to download application. http://www.argox.com/content2011.php?sno=0000033  Linking port: Transmit raw data 1 Byte a time. Developer can set four interfaces to their own connection.         Important    Remote link has to use Argox application, such as PhoenixVoler or Everlink from Argox.
  24  2.3.1 Remote link connection This section will show how to link PI series to PC with “Remote link” and enter “Message menu” to send message when the connection successful.    Use Remote link to connect PC with USB Step 1. After link USB cable between PI series and PC, press “Power” key to open PI series.    Step 2. Move curse to “Remote Link” and press “ENT” key.  Step 3. Enter “Remote I/F Select” and Choose “USB”. It will automatically go back
  25       Step 4. Choose “Connect”.    Step 5. In PhoenixVoler or Everlink, Click Comm setup will show the model number. Successfully connected to PC.
  26  Message Menu   Everlink, ControlCenter and PI series can send message to PI series. Press “Fn”+”^” key to enter Message Menu.       Read priority Msg.: It shows the priority message you receive.  Read Msg.: It shows the message you sent.  Send Msg.:    To Everlink: “Send to” is 9000  To ControlCenter: “Send to” is 9001  To otherPI series device: “Send to” default depends on SN last four number. To change ID, refer to “Equipment ID” in System menu.    Important  Sending message rely on Everlink. PI series must connect to Everlink then the message will start to send and receive.
  27  2.4  Attach the hand strap Sometimes you may need to do something and can’t hold your terminal on your hand. Or, you might accidentally drop your terminal between uses. Attach the hand strap is a useful way to resolve these issues. You can wrap the strap around your hand to secure it to your hand, or hang it on your hand to have both hands free to do other things. To attach the hand strap, do this: 1. Pinch the small loop and thread it into the two square holes under the battery cover.
  28  2. Thread the big loop into the small loop, and pull the big loop to tie a knot.         Important    Use hand strap when you collect barcode in case drop accident. PI series might shut down to protect data after drop.
  29  3 Controls and settings PI series offers three different layer menus. User Menu is for general users, System Menu is for supervisors or managers, and Supervisor Menu is for system administrators or engineers. Besides, press Fn+^ can enter Message Menu This chapter provides information about these menus. 3.1 User Menu  User Menu includes three frequently used settings. You can use them to run your program, connect your terminal to a computer or other device, or display your terminal’s information.
  30  3.1.1 Run Program It shows the program you download from your computer. To run a program, just select it and press ENT. If there’s no program, it will tell you “No program file.” For more information about how to connect to a computer and download programs from it, see PhoenixVoler or Everlink User guide. 3.1.2 Remote Link  It is for you to connect your terminal with Everlink or PhoenixVoler to computer. ■ Connect  It connects your terminal to computer after you select an interface.
  31  ■ Remote I/F Select  It provides interfaces, including COM port, USB, Bluetooth and WI-FI. To connect your terminal, do this: 1. Select Remote Link > Remote I/F Select > COM port/USB/Bluetooth/WI-FI. 2. Go up one level in the menu and select Connect.   Note  If you want to connect via Bluetooth or WI-FI, you need to enter Supervisor Menu and set up Bluetooth connection or WI-FI connection first. After completing the setting, you can connect your terminal from User Menu Connect.  3.1.3 Scanner(HID) It is for you to read and upload barcode data easily. Once you have connection to computer. Press “SCAN” key to read barcode and it will upload data. Go to CH 4 Application. see more in Everlink user guide.
  32    Note  Make sure you turn on the decode function(barcode default). 3.1.4 Information It displays your terminal’s information. IPL The IPL version. BOOT The boot version. Kernal The kernel version. Scanner The scanner’s firmware version. SN The serial number. DefLang The display language.
  33  3.2 System Menu Under System Menu, you can change system settings to meet your need and run some tests to see if your terminal is working properly. Press key 3 + 9 + Power to enter system menu. 3.2.1 Remote Link See the description in Remote Link in User Menu. 3.2.2 Disk info
  34  It provides the disk information, including the free, used and total disk space. By default, your terminal has two disks: C and D.   3.2.3 Timer setting  ■ Set date & time  You can set date and time here. ■ Set time format  You can set the time format here. It provides the 12-hour or 24-hour clock and only display in Status Bar.    C RAM For data memory D Flash For system and user’s application
  35  3.2.4 Environment  It provides settings for you to adjust different workplace or match your preference. ■ LCD contrast  It determines the contrast ratio. The bigger the number, the lower the contrast (the darker the screen).1~10 ■ Backlight timer  It determines how long the backlight stays on after you press a key.1~65535. Set 0 will always on. ■ Auto off timer  It turns off your terminal after a certain amount of time elapsed. The unit of time is the second. If you set it 0, your terminal is always turned on.30~65535   ■ Always on if DC in    It will always on when you plug DC power. Default is disable.
  36  ■ Key click  You can turn on or turn off the sound of keypad. ■ Vibration  It determines how long your terminal vibrates. The unit is 0.1 second, range is 1~255. Set 0 will turn it off. 3.2.5 Test  It provides various tests for you to check your terminal system.  ■ Memory test  It checks if the memory can be written and read properly. Note that this test removes all data stored in the memory, so remember to save your files in advance. ■ Buzzer test  It checks if the buzzer can make sound properly. You’ll hear the sound repeatedly plays from
  37  high to low and from low to high. If the sound is played smoothly, it means the buzzer works properly, otherwise the buzzer may have some issues. ■ LCD & LED test  It checks if the LCD display has bad pixels. ■ Keypad test  It checks if the keypad works properly when you press it. ■ Linking port test  It checks if the port works properly. You need to set a port to run this test. For more information about the port setting, see the description in Setting in Supervisor Menu.  After you set a port, do this: 1. Select the port you want to test, and press ENT. 2. Your terminal will show if the test is successful or failed after the test is complete. ■ Scanner test  It checks if your terminal can read bar codes when you press SCAN to scan bar codes. If the scan is successful, your terminal will vibrate and display the bar code data.   Note  When you do scanner test to barcode, turn on the function in Barcode config (Supervisor Menu).
  38   3.2.6 System info  See the description in Information in User Menu.
  39  3.3 Supervisor Menu  (1+3+0+PWR)Supervisor Menu provides advanced settings for you to configure. To protect the settings from being changed easily, you need to enter a password to access the menu. By default, the password is five zeros (00000).
  40  3.3.1 Remote Link  It is for you to connect your terminal with Everlink or PhoenixVoler to computer. ■ Connect  It connects your terminal to computer after you select an interface. ■ Remote I/F Select  It provides interfaces, including COM port, Bluetooth and WI-FI. ■ Remote I/F Set  It has three options: ∙ COM port  You can select a baud here.
  41  ∙ Bluetooth  It has three options: 1. Bluetooth setting: (1) Device name: Your terminal’s name. By default, the name is the serial number. (2) PIN code: The passkey for a Bluetooth connection. By default, the code is four zeros (0000). (3) Security mode: It has two options. a. Security: Your terminal will ask other devices to enter a PIN code when they try to connect to your terminal. b. Encryption: It encrypts the connection to prevent data theft. (4) Inquiry timeout: It determines how long your terminal stops searching other devices after a certain amount of time elapses. (5) Max response: It determines the maximum number of connectable devices your terminal lists. (6) Set peer device: It has two options. a. Set by search: Search other devices in the neighborhood. b. Set by keyin: Search another device by
  42  entering its Bluetooth MAC address. 2. Bluetooth test: You can use this option to test the Bluetooth connection after your terminal connects to a device. 3. Bluetooth info: It displays Bluetooth information, including the local address, device name and link address. ∙ WI-FI It has three options 1. Setting (1) WI-FI SSID: a. Set by search: Search WI-FI signal in the neighborhood. b. Set by keyin: Type New SSID to connect the WI-FI you prefer. (2) Network: It is the same as computer network. The Default is “Enable” DHCP to auto get IP Address, Subnet Mask and Gateway. Or you can “Disable” DHCP to set your WI-FI data. (3) Connect setting: Type “New IP” and “New Port” to get connection.   (4) System Scale: There are 3 Level to choose. The default is “High”
  43  (5) Power Saving: If Disable, WI-FI module will always awake to transmit data. Otherwise, WI-FI will automatically turn off.    2. TCP Test: Test WI-FI connection, the process need to wait about 3~15 seconds. PI series will show the connect success of fail on the screen.    3. Information: It displays WI-FI information.   (1) Remote port: show the page is under remote port.   (2) MAC: Show MAC address after you connect.   (3) DHCP: The status is Enable or Disable. (4) rIP: Current remote IP Address. (5) rPort: Current remote Port. 3.3.2 Format disk
  44  It formats a disk in your terminal. The system will ask you to confirm if you want to format, because it will remove all data stored in the disk. ■ Format C  Format the C disk. ■ Format D  Format the D disk. 3.3.3 Setting  It offers a variety of settings that you can change to meet your need. ■ Equipment ID  Your terminal’s ID. The default ID is four zeros (0000). You can replace it with a new ID. The ID needs to be a 4-digit number. ■ BIOS Password  It is the password of Supervisor Menu. The password needs to be a 5-digit number. ■ BIOS default  It resets all your terminal settings, including the password of Supervisor Menu.
  45  ■ Environment  It provides settings for you to adjust to adapt to different workplaces or match your preference. For the first five options, see the description in Environment in System Menu. ∙ Power on  It determines the screen displayed in User Menu after you turn on your terminal. 1. Resume: The system displays the last screen you visited in User Menu every time you turn on your terminal. 2. Reset: The system displays the default screen in User Menu every time you turn on your terminal. ∙ Status bar  You can choose if you want to display the status bar. ■ Scanner  It provides several settings for the scanning functionality. ∙ Reading test  See the description in Test in System Menu. ∙ Indication  It has two options: 1. LED: You can turn on or turn off the LED. 2. Beep: You can turn on or turn off beeps. ∙ Code ID  Code ID is an identifier for a bar code. It has two options:
  46  1. Transmission: It has two modes: Proprietary ID or AIM ID. You can choose either of them. Proprietary ID is defined by Argox. AIM ID is defined by the AIM organization. 2. Position: You can insert the code ID before or after the bar code data. ∙ Invert Image  When you turn on this feature, you can scan both regular and inverted bar codes. ∙ Preamble  Add a character or characters before a bar code. ∙ Postamble  Add a character or characters after a bar code. ∙ Barcode config  It provides several settings for each bar code type. Change them to meet your need. The list below shows the bar code types system default setting. Bar Code Type ON OFF 1. Code-11  ○ 2. Code-39 ○  3. Code-93  ○ 4. Code-128 ○  5. EAN-8 ○  6. EAN-13 ○  7. UPC-A ○
  47  8. UPC-E ○  9. Industrial 25  ○ 10. Interleaved 25 ○  11. Standard 25  ○ 12. MSI-Plessey  ○ 13. UK-Plessey  ○ 14. RSS 14  ○ 15. RSS Limited  ○ 16. RSS Expanded  ○ 17. CODABAR  ○ 18. Telepen  ○ 19. Matrix 2 of 5  ○ 20. China Post  ○ 21. Pharmacode  ○  ■ Language  You can change the language for the system to display items in the user interface. It has two options: English, TC (Traditional Chinese) and SC(Simple Chinese).  ■ Linking port  You can decide which port you want to use and configure its settings. To set a port, do this: 1. In Port IF select, select a port and its interface. 2. In Port IF setup, select the port you choose in the previous step, and configure the settings of its
  48  interface. ∙ Port IF select  It has four ports. Select one of them and choose its interface. You can choose COM, USB, Bluetooth and WI-FI. If you don’t want to use interface, choose None. ∙ Port IF setup  It provides the settings of COM, Bluetooth and WI-FI. For more information about the settings, see Remote Link in Supervisor Menu. ∙ Port info  It displays the port information. Press Up Arrow and Down Arrow to check different ports.        重要    Linking port is for development usage and transmit raw data. See more information, go to CH 2.3 Connection
  49  3.3.4 Information  It displays your terminal’s information.  IPL The IPL version. BOOT The boot version. Kernal The kernel version. Scanner The scanner’s firmware version. SN The serial number. HW Ver. The PCBA (Printed Circuit Board Assembly) version. HW Int. The hardware version. DefLang The display language.
  50  4 Applications Argox provides multiple applications for communication and developments as below:    Communication   PhoenixVoler Upload and Download firmware or application easily. Recommend developer.   Everlink   Manage multiple PI series with files transmission, message sending and history data function.   Control center Remote-end of manage program can link multiple Everlink and provide Cloud operation.  Development application Skywalker User friendly software development kit  Go to Argox website to get more applications and user guide http://www.argox.com/content2011.php?sno=0000033   Note   PI Series accept “.bas” and “.bin” file from Basic and C compiler.
  51  5 Troubleshooting 5.1 Hardware issues Speaker is not working or volume is too low. ■ Make sure the speaker hole is not blocked. ■ Test is in the system menu, use Test to check speaker. Keypad does not response. ■ Test is in the system menu, use Test to check keypad. ■ The system might be crush. Use Scan + Power key to warm reset or cold reset (hold 5 seconds). My terminal keeps turning itself off or can not open. ■ If you’re using batteries, check them and see if they need to be charged. ■ If your terminal is connected using USB or RS-232 cable, make sure the cable is tightly plugged. ■ The duration of Auto off Timer is too short. Set it a longer duration from Auto off timer in Environment
  52  5.2 Communication issues Receive or transmit problem on USB ■ Check USB connector is plugged correctly. ■ Check Remote Link set is USB and select the right PI series name on computer. ■ Restart PI series and unplug the USB and try again. Receive or transmit problem on RS-232 ■ Check RS-232 connector is plugged correctly. ■ Check Remote Link set is COM port and select the same port on computer. ■ Restart PI series and unplug the RS-232 and try again. Receive or transmit problem on Bluetooth ■ Check Remote Link set is Bluetooth port and Bluetooth setting is correct. ■ Be sure PI series is in the Bluetooth range
  53  5.3 Barcode scanning issues Barcode can not be read   ■ Change the angle between the bar code and the terminal. ■ Change the distance between the bar code and the terminal. ■ Clean the scanning window slightly of the terminal(make sure without scratch). ■ Enabled the bar code symbology in supervisor menu > 3.Setting > 5.Scanner > 7.Barcode config.
   54  6 Specifications  General Characteristics OS Argox Proprietary CPU ARM926EJ-S RAM 16 / 32 MB DRAM ROM 20 / 60 MB Flash Display White gray mono STN LCD 160*160 Indicator LED Blue, Green and Red; Beeper; Vibration Motor Keypad 25 Alpha-Numeric keys (Including 10 function keys, 3 programmable hot keys) Accessory Holder (Standard), Power Supply Dimensions 145.0mm (L) x 55.0mm (W) x 26.0mm (H) Weight 230g with battery
   55   Scanner  PI-10x0 PI-11x0 PI-12x0 (coming soon) Scanner system CCD Laser 2D Area imager Resolution 5 mil at PCS 90% 4 mil 5 mil (optional 3 mil) Depth of field 350mm   (Code 39, 13 mil, PCS 90%) 254 mm (13 mil) 390 mm (13 mil) Scanning rate 200 scan/sec 100 scan/sec  Decode capability 1D barcode: Code-11、Code-39、Code-93、Code-128、EAN-8、EAN-13、UPC-A、UPC-E、Industrial 25、Interleaved 25、Standard 25、MSI-Plessey、UK-Plessey、RSS 14、RSS Limited、RSS Expanded、CODABAR、Telepen、Matrix 2 of 5、China Post、Pharmacode   2D bar code: Data Matrix, QRcode, PDF417   Communication
   56  Communication  PI-1x00 PI-1x10 PI-1x30 WPAN  Bluetooth Class2, BT2.1+EDR Bluetooth Class2, BT2.1+EDR WLAN   Wi-Fi 802.11b/g/n I/O Interface USB 2.0 / RS-232 USB 2.0 / RS-232 USB 2.0 / RS-232  Expansion Storage Micro SD (up to 16 GB)  Developing Tools Software Software Development Kit (SDK), Skywalker (Proprietary application software generator) Programming Language C language, BASIC language  Power Battery 2 AA Alkaline or NIMH Battery (charged by USB or optional power supply) Rating 5Vdc    2A
   57   Physical and Environment Operating Temperature -10℃  ~ 60℃  / 14F ~ 140F Storage Temperature -20℃  ~ 70℃  / -4F ~ 158F Humidity 1) Operating: Non-condensed 10 ~ 90%           2) Storage: Non-condensed 5 ~ 95% Impact Resistance 1) Terminal 1.5M/5ft, Holder 0.9M / (4 drops per 6 sides)    2) IP54 Electrostatic Discharge 1) +/- 15 KV air discharge        2) +/- 8 KV direct discharge EMC Regulation FCC, CE
   58  Appendix A Skywalker Reader Default (*)                                                     Command1 Command2 Option/Limitation Indication LED indication Disable Enable * Buzzer indication Disable Enable * Transmission Preamble transmission Disable * Enable Postamble transmission Disable * Enable Code ID position Before code data * After code data Code ID transmission Disable * Proprietary ID AIM ID Code length transmission Disable * Enable Code name transmission Disable * Enable  Case conversion Disable * Upper case Lower case
   59   Scan  Double confirm 0 ~ 9 0 *  Global min. code length 0 ~ 99 4 *  Global max. code length 0 ~ 99 63 *  Inverted image scan Disable * Enable  String setting  Prefix characters setting 0 * 0x00 ~ 0xff ASCII code 12 characters.  Suffix characters setting 0 * 0x00 ~ 0xff ASCII code 12 characters.  Preamble characters settings 0 * 0x00 ~ 0xff ASCII code 12 characters.  Postamble characters settings 0 * 0x00 ~ 0xff ASCII code 12 characters.
   60   Code 11  Read Disable * Enable  Check-sum transmit /verify Disable/Disable Disable/One digit * Disable/Two digits Enable/One digit Enable/Two digits  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <O> 0x00 ~ 0xff ASCII code(1 or 2 bytes) Code 39 Read Disable Enable * Check-sum transmit /verify Disable/Disable * Disable/Enable Enable /Enable Max. code length 0 ~ 64
   61  0 * Min. code length 0 ~ 64 1 * Truncate leading 0 ~ 20 0 * Truncate ending 0 ~ 15 0 *  Code ID setting <*> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Format Standard * Full ASCII  Start/stop transmission Disable * Enable  Code 93  Read Disable * Enable  Check-sum transmit /verify Disable/Disable   Disable/Enable * Enable /Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  0 ~ 15
   62  Truncate leading 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <&> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Code 128  Read Disable Enable *  Check-sum transmit /verify Disable/Disable Disable/Enable * Enable /Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 1 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <#> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Format Standard * UCC.EAN 128  <#>
   63  UCC/EAN 128 ID setting 0x00 ~ 0xff ASCII code(1 bytes)  Concatenation code 0x1D * 0x00 ~ 0xff ASCII code(1 bytes) Codabar  Read Disable * Enable  Check-sum transmit /verify Disable/Disable * Disable/Enable Enable /Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <%> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Start/stop type ABCD/ABCD * abcd/abcd ABCD/TN*E abcd/tn*e
   64   Start/stop transmission Disable * Enable  EAN 8  Read Disable Enable *  Check-sum transmission Disable Enable *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <FF> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Supplement digits   None *   2 digits   5 digits   2, 5 digits   UCC/EAN 128   2, UCC/EAN 128   5, UCC/EAN 128  All  Truncation/expansion   None *   Truncate leading zero
   65    Expand to EAN 13  Expansion Disable * Enable  EAN 13  Read Disable Enable *  Check-sum transmission Disable Enable *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <F> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Supplement digits   None *   2 digits   5 digits   2, 5 digits   UCC/EAN 128   2, UCC/EAN 128   5, UCC/EAN 128  All  ISBN/ISSN conversion Disable * Enable
   66   Industrial 2 of 5  Read Disable * Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <i> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Interleaved 2 of 5 Read Disable Enable *  Check-sum transmit /verify Disable/Disable * Disable/Enable Enable /Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  0 ~ 15
   67  Truncate ending 0 *  Code ID setting <i> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Standard 2 of 5  Read Disable * Enable  Check-sum transmit /verify Disable/Disable * Disable/Enable Enable /Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <i> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  MSI Plessey  Read Disable * Enable  Check-sum transmit /verify N/disable * N/MOD 10
   68  N/Mod 10,10 N/mod 11,10 Y/ Mod10 Y/ Mod 10,10 Y/ Mod 11/10  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <@> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  UK Plessey  Read Disable * Enable  Check-sum transmit /verify Disable/Disable Disable/Enable * Enable /Enable  Max. code length 0 ~ 64 0 *  0 ~ 64
   69  Min. code length 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <@> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Telepen  Read Disable * Enable  Check-sum transmit /verify Disable/Disable * Disable/Enable Enable /Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <S> 0x00 ~ 0xff ASCII code(1 or 2 bytes)    Numeric *
   70  Format   Full ASCII  UPCA  Read Disable Enable *  Check-sum transmission Disable Enable *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <A> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Supplement digits   None *   2 digits   5 digtis   2, 5 digits   UCC/EAN 128   2, UCC/EAN 128   5, UCC/EAN 128  All  Truncate/expansion   None   Truncate leading zero *   Expand to EAN 13   Disable
   71  UPCE Read Enable *  Check-sum transmission Disable Enable *  Truncate ending 0 ~ 15 0 *  Code ID setting <E> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Supplement digits   None *   2 digits   5 digits   2, 5 digits   UCC/EAN 128   2, UCC/EAN 128   5, UCC/EAN 128  All  Truncate/expansion   None *   Truncate leading zero   Expand to EAN 13   Expand to UPCA  Expansion Disable * Enable  UPCE-1 Disable * Enable
   72   Matrix 25  Read Disable * Enable  Check-sum transmit /verify Disable/Disable * Disable/Enable Enable /Enable  Max. code length 0 ~ 64 0 *  Min. code length 0 ~ 64 0 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <B> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  China post  Read Disable * Enable  Max. code length 0 ~ 64 11 *  Min. code length 0 ~ 64 11 *  Truncate leading 0 ~ 15 0 *  0 ~ 15
   73  Truncate ending 0 *  Code ID setting <t> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  RSS 14  Read Disable * Enable  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <R4> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  UCC/EAN 128 emulation Disable * Enable  RSS Limited  Read Disable * Enable  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <RL> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Disable *
   74  UCC/EAN 128 emulation Enable  RSS Expanded  Read Disable * Enable  Max. code length 0 ~ 99 99 *  Min. code length 0 ~ 99 1 *  Truncate leading 0 ~ 15 0 *  Truncate ending 0 ~ 15 0 *  Code ID setting <RX> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  UCC/EAN 128 emulation Disable * Enable  Italian Pharmacode 39  Read Disable * Enable  Max. code length 0 ~ 64 12 *  Min. code length 0 ~ 64 9 *  Truncate leading 0 ~ 15 0 *
   75   Truncate ending 0 ~ 15 0 *  Code ID setting <p> 0x00 ~ 0xff ASCII code(1 or 2 bytes)  Leading “A” Disable * Enable