Aruba Networks AP105SDR Aruba AP-105 Wireless Access Point User Manual
Aruba Networks, Inc. Aruba AP-105 Wireless Access Point
Contents
- 1. User Installation Guide
- 2. Users Installation Guide
- 3. Manual
Users Installation Guide
IAP-105 Wireless Access Point Installation Guide Power Connector The Aruba IAP-105 wireless access point supports the IEEE 802.11n standard for high-performance WLAN. This access point uses MIMO (Multiple-in, Multipleout) technology and other high-throughput mode techniques to deliver highperformance, 802.11n 2.4 GHz and 5 GHz functionality while simultaneously supporting existing 802.11a/b/g wireless services. The IAP-105 access point works only in conjunction with an Aruba Controller. ENET AP Pre-Installation Checklist Before installing your IAP-105 access point, be sure that you have the following: ďŹ ďŹ ďŹ ďŹ 1.25A 12V Wireless transceiver Protocol-independent networking functionality IEEE 802.11a/b/g/n operation as a wireless access point IEEE 802.11a/b/g/n operation as a wireless air monitor Compatibility with IEEE 802.3af PoE Central management configuration and upgrades through an Aruba Controller ENET ďŹ CONSOLE ďŹ AP105_002 Package Contents ďŹ ďŹ CAT5 UTP cable of required length One of the following power sources: ďŽ IEEE 802.3af-compliant Power over Ethernet (PoE) source ďŽ Supports full functionality for IAP-105 ďŽ The POE source can be any power source equipment (PSE) controller or midspan PSE device ďŽ Aruba AP AC-DC adapter kit (sold separately) Aruba Controller provisioned on the network: ďŽ Layer 2/3 network connectivity to your access point ďŽ One of the following network services: IAP-105 access point (1 unit or a pack of 10) Installation guide (this document) ďŹ Aruba Discovery Protocol (ADP) ďŹ DNS server with an âAâ record ďŹ DHCP Server with vendor-specific options Console Port Use the console port to connect to a terminal for direct local management. 1. Verify pre-installation connectivity. Ethernet Port 2. Identify the specific installation location for each AP. IAP-105 is equipped with a single 10/100/1000Base-T (RJ-45) auto-sensing, MDI/ MDX wired-network connectivity port. This port supports IEEE 802.3af Power over Ethernet (PoE) compliance, accepting 48VDC as a standard defined Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE midspan injector, or network infrastructure that supports PoE. 3. Install each AP. 4. Verify post-installation connectivity. 5. Configure each AP. If PoE is not available, an optional Aruba AP AC-DC adapter kit (sold separately) can be used to power the IAP-105. The reset button can be used to return the AP to factory default settings.. To reset the AP: AP105_005 1. Power off the AP. 2. Press and hold the reset button using a small, narrow object, such as a paperclip. 3. Power-on the AP without releasing the reset button. The power LED will flash within 5 seconds. IAP-105 Hardware Overview 4. Release the reset button. Figure 2 IAP-105 Front The power LED will flash again within 15 seconds indicating that the reset is completed. The AP will now continue to boot with the factory default settings. Before You Begin 105 FCC Statement: Improper termination of access points installed in the United States configured to non-US model controllers will be in violation of the FCC grant of equipment authorization. Any such willful or intentional violation may result in a requirement by the FCC for immediate termination of operation and may be subject to forfeiture (47 CFR 1.80). AP105_001 11B/G/N 11A/N LEDs The IAP-105 is equipped with four LEDs that indicate the status of the various components of the AP. ďŹ Installing the AP Service to all Aruba Networks products should be performed by trained service personnel only. PWR: Indicates whether or not the IAP-105 is powered-on ENET: Indicates the status of the IAP-105âs Ethernet port 11A/N: Indicates the status of the 802.11a/n radio 11B/G/N: Indicates the status of the 802.11b/g/n radio For information about the IAP-105âs LED behavior, see Table 1 on page 2. Produit rĂŠseau local radio basse puissance operant dans la bande frĂŠquence 2.4 GHz et 5 GHz. Merci de vous referrer au ArubaOS User Guide pour les details des restrictions. Low Power FunkLAN Produkt, das im 2.4 GHz und im 5 GHz Band arbeitet. Weitere Informationen bezlĂźglich Einschränkungen finden Sie im ArubaOS User Guide. Apparati Radio LAN a bassa Potenza, operanti a 2.4 GHz e 5 GHz. Fare riferimento alla ArubaOS User Guide per avere informazioni detagliate sulle restrizioni. Pre-Installation Network Requirements After WLAN planning is complete and the appropriate products and their placement have been determined, the Aruba controller(s) must be installed and initial setup performed before the Aruba APs are deployed. Using the Integrated Wall-Mounting Slots The keyhole-shaped slots on the back of the AP can be used to attach the device upright to an indoor wall or shelf. When you choose the mounting location, allow additional space at the right of the unit for cables. 1. Since the ports are on the back of the device, make sure that you mount the AP is such a way that there is a clear path to the Ethernet port, such as a predrilled hole in the mounting surface. 2. At the mounting location, install two screw on the wall or shelf, 1 7/8 inches (4.7 cm) apart. If you are attaching the device to drywall, Aruba recommends using appropriate wall anchors (not included). Access points are radio transmission devices and as such are subject to governmental regulation. Network administrators responsible for the configuration and operation of access points must comply with local broadcast regulations. Specifically, access points must use channel assignments appropriate to the location in which the access point will be used. Figure 4 Installing the IAP-105 Access Point on a Wall 3. Align the mounting slots on the rear of the AP over the screws and slide the unit into place (see Figure 4). Verifying Pre-Installation Connectivity Before you install APs in a network environment, make sure that the APs are able to locate and connect to the controller after power on. Specifically, you must verify the following conditions: ďŹ When connected to the network, each AP is assigned a valid IP address ďŹ APs are able to locate the controller Refer to the ArubaOS Quick Start Guide for instructions on locating and connecting to the controller. Identifying Specific Installation Locations EU Statement: Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands. Please refer to the ArubaOS User Guide for details on restrictions. ďŹ RF interference sources include: ďŹ Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones) ďŹ Cordless headset such as those used in call centers or lunch rooms Aruba Networks, Inc., in compliance with governmental requirements, has designed the IAP-105 access points so that only authorized network administrators can change the settings. For more information about AP configuration, refer to the ArubaOS Quick Start Guide and ArubaOS User Guide. Reset Button ďŹ ďŹ Metal ObjectsâMetal pans between floors, rebar, fire doors, air conditioning/ heating ducts, mesh windows, blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets Do not place an AP between two air conditioning/heating ducts. Make sure that APs are placed below ducts to avoid RF disturbances. Successful setup of an IAP-105 access point consists of five tasks, which must be performed in this order: DC Power Socket ďŹ ďŹ Summary of the Setup Process Figure 1 IAP-105 ENET RF reflectors include: Reset Button Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials. Use these materials to repack and return the unit to the supplier if needed. PWR RF absorbers include: ďŹ Cement/concreteâOld concrete has high levels of water dissipation, which dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration within the concrete, blocking RF signals. ďŹ Natural ItemsâFish tanks, water fountains, ponds, and trees ďŹ Brick RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems. You can mount the IAP-105 access point on a wall or on the ceiling. Use the AP placement map generated by Arubaâs RF Plan software application to determine the proper installation location(s). Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should have been accounted for during the planning phase and adjusted for in RF plan. AP105_003 ďŹ ďŹ CONSOLE The Aruba IAP-105 access point provides the following capabilities: ďŹ For initial setup of the controller, refer to the ArubaOS Quick Start Guide for the software version installed on your controller. Figure 3 IAP-105 Rear Using the Integrated Ceiling Tile Rail Slots The snap-in tile rail slots on the rear of the AP can be used to securely attach the device directly to a 15/16" wide, standard ceiling tile rail. Make sure the AP fits securely on the ceiling tile rail when hanging the device from the ceiling; poor installation could cause it to fall onto people or equipment. 1. Pull the necessary cables through a prepared hole in the ceiling tile near where the AP will be placed. 2. If necessary, connect the console cable to the console port on the back of the AP. Hold the AP next to the ceiling tile rail with the ceiling tile rail mounting slots at approximately a 30-degree angle to the ceiling tile rail (see Figure 5). Make sure that any cable slack is above the ceiling tile. Figure 5 Orienting the Ceiling Tile Rail Mounting Slots Identifying Known RF Absorbers/Reflectors/Interference Sources Identifying known RF absorbers, reflectors, and interference sources while in the field during the installation phase is critical. Make sure that these sources are taken into consideration when you attach an AP to its fixed location. AP105_004 About the Aruba IAP-105 Access Points 3. Pushing toward the ceiling tile, rotate the AP clockwise until the device clicks into place on the ceiling tile rail. Connecting Required Cables Table 1 IAP-105 Series LED Meanings LED Color/State Meaning 11A/N Off 5 GHz radio is disabled Install cables in accordance with all applicable local and national regulations and practices. Amber áłâŚáłáâ ˝äźŕťáŻ˘ Hazardous Materials Declaration äźÓ৥⿠(Parts) 5 GHz radio enabled in WLAN mode âŹäáľ (PCA Boards) á´áşăÓ Ethernet Ports Green The RJ45 Ethernet port (ENET) supports 10/100/1000Base-T auto-sensing MDI/ MDX connections. Use these ports to connect the AP to a twisted pair Ethernet LAN segment or directly to an Aruba Controller. Use a 4- or 8-conductor, Category 5 UTP cable up to 100 m (325 feet) long. Green flashing 2.4 GHz radio disabled The 10/100/1000 Mbps Ethernet port is on the back of the AP. The port has an RJ45 female connector with the pin-outs shown in Figure 6. Amber 2.4 GHz radio enabled in WLAN mode Figure 6 Gigabit Ethernet Port Pin-Out Green 2.4 GHz radio enabled in 11n mode Green flashing 2.4 GHz Air Monitor or RF Protect mode RJ-45 Female Pin-Out Signal Name Function BI_DA+ BI_DABI_DB+ BI_DC+ BI_DCBI_DBBI_DD+ BI_DD- Bi-directional pair +A Bi-directional pair -A Bi-directional pair +B Bi-directional pair +C Bi-directional pair -C Bi-directional pair -B Bi-directional pair +D Bi-directional pair -D Electrical The serial console port (Console) allows you to connect the AP to a serial terminal or a laptop for direct local management. This port is an RJ-45 female connector with the pinouts described in Figure 7. Connect this port in one of the following ways: ďŹ Connect it directly to a terminal or terminal server using an Ethernet cable. ďŹ Use a modular adapter to convert the RJ-45 (female) connector on the AP to a DB-9 (male) connector, and connect the adapter to a laptop using an RS-232 cable. See Figure 8 for connector details of the adapter. Figure 7 Serial Port Pin-Out ďŹ Ethernet: ďŽ 1 x 10/100/1000Base-T auto-sensing Ethernet RJ-45 Interfaces ďŽ MDI/MDX ďŽ IEEE 802.3 (10Base-T), IEEE 802.3u (100Base-T). IEEE 802.3ab (1000Base-T) ďŽ Power over Ethernet (IEEE 802.3af compliant), 48V DC/350mA (see Figure 6 for pin configuration) Power: ďŽ 12 VDC power interface, supports powering through an AC-to-DC power adapter Proper Disposal of Aruba Equipment Ground RxD TxD Direction Input Output Power Connection Ćť Ćť Ćť Ćť Ćť Ćť IAP-105 Wireless Access Point 㸟âźäšáłâŚáłáâ ˝äźŕłźäšäźÓá áłŕ´äźá´¤áĐâąŕ§żäŁŕ´ŕłź SJ/T11363-2006 áˇâŤŢâŹăžá Žâąä°¤äŁă˝âŇšĎÇ Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard. Installation Guide This table shows where these substances may be found in the supply chain of electronic information products, as of the date of sale of the enclosed product. â¸áˇáŤĐäŠáá âŕŚŃťŕŞâąâŚÖąŐ⍟ᳳáˇáŤáś¤ŃŻäłäźÓÓŽáłĎϞϥৠâąâŚÖąŐ⍟ᳳ Őŕ˝âŹâ´ŕ¤ŠâŤÜâŹáżľŕ´Ť äŕłźÝŃťŕŞĎ â¸âŚÖąŐ⫼ᳳ䰤াä⍟ѢѝŕŞá°ŕłźŃťŕŞá âŤÝ âŹĐá ăžá Žâąá´ľÓĎášÔ° The Environment- Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here. The Environment- Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual. Safety and Regulatory Compliance Contacting Aruba Networks Aruba Networks provides a multi-language document that contains countryspecific restrictions and additional safety and regulatory information for all Aruba access points. This document can be viewed or downloaded from the following location: www.arubanetworks.com/safety_addendum. Table 1 The device will be electronically labeled and the FCC ID will be displayed via the controller WebUI under the About menu RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems. For the most current information about Global Environmental Compliance and Aruba products, see our website at www.arubanetworks.com. Waste of Electrical and Electronic Equipment Aruba products at end of life are subject to separate collection and treatment in the EU Member States, Norway, and Switzerland and therefore are marked with the symbol shown at the left (crossed-out wheelie bin). The treatment applied at end of life of these products in these countries shall comply with the applicable national laws of countries implementing Directive 2002/96EC on Waste of Electrical and Electronic Equipment (WEEE). If both POE and DC power are available, the AP uses POE even when there is not enough POE voltage available to power the AP. Verifying Post-Installation Connectivity The integrated LEDs on the AP can be used to verify that the AP is receiving power and initializing successfully (see Table 1). Refer to the ArubaOS Quick Start Guide for further details on verifying post-installation network connectivity. European Union RoHS Aruba products also comply with the EU Restriction of Hazardous Substances Directive 2002/95/EC (RoHS). EU RoHS restricts the use of specific hazardous materials in the manufacture of electrical and electronic equipment. Specifically, restricted materials under the RoHS Directive are Lead (including Solder used in printed circuit assemblies), Cadmium, Mercury, Hexavalent Chromium, and Bromine. Some Aruba products are subject to the exemptions listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit assemblies). Products and packaging will be marked with the âRoHSâ label shown at the left indicating conformance to this Directive. China RoHS Table 1 IAP-105 Series LED Meanings LED Color/State Meaning PWR Off No power to AP Green flashing System initializing Red steady System failed to initialize, contact TAC Green steady Power on, device ready Off No link Green on 1000 Mbps link Amber on 10/100 Mbps link Green flashing Ethernet link activity 10 Aruba products also comply with China environmental declaration requirements and are labeled with the âEFUP 10â label shown at the left. Web Site Support Main Site http://www.arubanetworks.com Support Site https://support.arubanetworks.com Software Licensing Site https://licensing.arubanetworks.com/login.php Wireless Security Incident Response Team (WSIRT) http://www.arubanetworks.com/support/wsirt.php Americas and APAC Support Email support@arubanetworks.com EMEA Support Email emea.support@arubanetworks.com WSIRT Email Please email details of any security problem found in an Aruba product. wsirt@arubanetworks.com Table 2 ďŹ IEC 60601-1-2: 2007 EN 60601-1-2: 2007 This equipment has been tested and found to comply with the limits of the standard for medical devices, IEC 60601-1-2:2007. The unit also complies with the requirements of EN 60601-1-2:2007, providing the presumption of compliance to the European Unionâs Medical Device Directive 2007/47/EC. The limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the manufacturerâs instructions may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes interference with other devices, which may be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: ďŹ ďŹ The IAP-105 has a single 12V DC power jack socket to support powering through an AC-to-DC power adapter. ENET (10/100/1000 Mbps) Ćť áäŤŕŹĐ᎚âąá ŕŹŃťŕŞá´ă¸źá°âźŐŻá¨äŤâąâŹá¤ÖľáŃťŕŞŕ§ăŕŁŕ§żäŃŻâ ˝äźÇ ďŹ DB-9 Male Pin-Out DB-9 Ćť EMC Compliance and Warning Statement For additional specifications on this product, please refer to the data sheet. The data sheet can be found at www.arubanetworks.com. Figure 8 RJ-45 (Female) to DB-9 (Male) Modular Adapter Conversion RJ-45 TxD GND RxD Ćť Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard. If a power adapter other than the one provided by Aruba Networks is used in the US or Canada, it should be cULus (NRTL) Listed, with an output rated 12 VDC, minimum 1.25A, marked âLPSâ or âClass 2,â and suitable for plugging into a standard power receptacle in the US and Canada. TxD GND GND RxD Internal Connections Ćť hË ă¸źâźäšáłâŚáłáâ ˝äźăáĽŕłźäšäźÓâąáś¤Ďŕ´äźá´¤áĐâąŕ§żäŁäß6-7áˇâŤŢâŹăžá Žâąä°¤äŁă˝âÇ RJ-45 Female Pin-Out Direction Input Output ໮âŃ ăŁäŽ 3%'( ďŹ Serial Console Port Ⲡ+J Product Specifications Serial Console Port RJ-45 Female Pin-Out TxD GND RxD Direction Input Output (Mechanical Sub-Assemblies) ĆťË 5 GHz Air Monitor or RF Protect mode Off 1000Base-T Gigabit Ethernet Port 11B/G/N 5 GHz radio enabled in 11n mode áłâŚáłáâ ˝äźáŞâŤÜâŹă´(Hazardous Substance) äŹ ÝÓäŤ ŕťŽâă¨ăŁ &G &U 3%% äŞ 3E ďŹ ďŹ Reorient or relocate the device receiving the interference. Increase the separation between the equipment. Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected. Consult the manufacturer or field service technician for help. The Model IAP-105 do not have an Applied Part as defined in IEC 60601-1. The protection against electric shock is Class ll. Telephone Support Aruba Corporate +1 (408) 227-4500 FAX +1 (408) 227-4550 Copyright Š 2010 Aruba Networks, Inc. AirWaveÂŽ, Aruba NetworksÂŽ, Aruba Mobility Management SystemÂŽ, Bluescanner, For Wireless That WorksÂŽ, Mobile Edge Architecture, People Move. Networks Must Follow., RFProtectÂŽ, The All Wireless Workplace Is Now Open For Business, and The Mobile Edge CompanyÂŽ are trademarks of Aruba Networks, Inc. All rights reserved. All other trademarks are the property of their respective owners. Open Source Code Certain Aruba products include Open Source software code developed by third parties, including software code subject to the GNU General Public License ("GPL"), GNU Lesser General Public License ("LGPL"), or other Open Source Licenses. The Open Source code used can be found at this site: http://www.arubanetworks.com/open_source Legal Notice The use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate other vendors' VPN client devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies, in full, Aruba Networks, Inc. from any and all legal actions that might be taken against it with respect to infringement of copyright on behalf of those vendors. Warranty This hardware product is protected by the Aruba Limited Lifetime warranty. Altering this device (such as painting it) voids the warranty. Device is not protected against ingress of liquids and has a protection class of IPX0 as defined by IEC 60601-1 and IEC 60529. Equipment not suitable for use in the presence of flammable mixtures. The unit is considered âContinuous Operationâ equipment as defined by IEC 60601-1. Power Consumption â 48 VDC 802.3af power over Ethernet or 12VDC, 1.25A for external AC supplied power (adapter sold separately); Maximum power consumption â 12.5W. Mechanical Dimensions: 132mm x 135mm x 45mm; 300g. Environmental: Operating Temp: 0° C to +50° C (+32° F to +122° F); Humidity: 5 to 95% non-condensing. Storage Temp: -40° CS to +70° C (-40°F to +158°F). www.arubanetworks.com 1344 Crossman Avenue Sunnyvale, California 94089 Phone: 408.227.4500 Fax 408.227.4550 IAP-105 Wireless Access Point | Installation Guide Part Number 0510860-01 | January 2011
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:12:18 Format : application/pdf Title : untitled Create Date : 2009:07:01 14:54:10Z Creator Tool : FrameMaker 9.0 Modify Date : 2011:02:04 00:20:44+05:30 Metadata Date : 2011:02:04 00:20:44+05:30 Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:ec2ec61d-c154-44ba-a44c-a912db36ad4c Instance ID : uuid:70eadb67-29c0-4c12-8b2d-88f8af0d9ea1 Page Mode : UseNone Page Count : 2 Creator : FrameMaker 9.0EXIF Metadata provided by EXIF.tools