Ascensia Diabetes Care US N1 Wireless Blood Glucose Monitoring System User Manual
Bayer HealthCare Diabetes Care Wireless Blood Glucose Monitoring System
Contents
- 1. Manual 1
- 2. Manual 2
Manual 1
LINK WIRELESS BLOOD GLUCOSE MONITORING SYSTEM 93 USER GUIDE 1M CTS-103_CntrLINK_UG_Master_FpB4_v7.indd ofc1 FONTS 1600 Sherwin Ave. Des Plaines, IL 60018 T 847.296.6000 DATE: CLIENT: DESCRIPTION: SCHAWK JOB#: BAN#: SKU#: DIMENSIONS: PRINTER SPEC: V-7 February 7, 2011 Bayer HealthCare Contour Link User Guide Master 905480 CTS-103 Rev. 11/10 N/A 6.0" (H) x 4.0" (W) PUSG0517 REV B ENGLISH 2/7/11 3:59:49 PM Contour Link User Guide Master Alt#1 - 12/02/10 Color and Copy Changes Alt#2 - 12/07/10 Copy Changes Alt#3 - 12/15/10 Repagination Alt#4 - 01/24/11 Copy Changes Alt#5 - 01/28/11 Copy Changes Alt#6 - 02/01/11 Copy Changes Alt#7 - 02/07/11 Copy Changes Frutiger, Helvetica, Times, Zapf Dingbats, Berthold Akzidenz Grotesk COLORS PROCESS CYAN PROCESS MAGENTA PROCESS YELLOW PROCESS BLACK PANTONE 144 C PANTONE 072 C PANTONE 201 C Additional Materials Getting Ready to Test ......................................................................10 Getting the Blood Drop...................................................................12 Fingertip Testing .....................................................................12 Testing Your Blood ..........................................................................13 Turning Off the Send Option for a Single Test Result........................15 Cleaning and Disinfection ...............................................................18 Control Solution Testing ..................................................................23 Setting Your Options .......................................................................26 Setting the Send Option, Time, Date, and Sound ....................26 Setting the Markers and Test Reminder Alarm ........................29 Setting the Test Reminder Alarm Time ....................................29 Using the Markers and Test Reminder Alarm ...................................30 Viewing Stored Results....................................................................36 Important Important Information ......................................................................2 Your Testing Tools .............................................................................3 Your Meter Display............................................................................4 Important Safety Instructions ............................................................5 Your Meter Features..........................................................................6 Important Things to Know ................................................................7 First Things First: Talking to Your Compatible Medtronic Device........... 8 Before You Begin ..............................................................................9 Testing Table of Contents Options Thank you for choosing Bayer's CONTOUR® LINK blood glucose monitoring system! We are proud to be your partner in helping you manage your diabetes. The CONTOUR® LINK meter does much more than test your blood glucose — it automatically sends your blood glucose result to compatible* designated Medtronic partner devices using a wireless, radio frequency transmission. The CONTOUR LINK blood glucose monitoring system is intended for use by persons with diabetes in home settings for the measurement of glucose in whole blood, and is for single-patient use only. The CONTOUR LINK blood glucose monitoring system is indicated for use with capillary whole blood samples drawn from the fingertip. Critically ill patients (e.g. those with severe hypotension or shock, hyperglycemic-hyperosmolar state, hypoxia, severe dehydration, diabetic ketoacidosis) should not be tested with blood glucose meters because inaccurate results may occur. • M ICROLET ®2 Lancing Device — Use for fingertip puncture with Bayer's MICROLET lancet. Error Codes and Symbols ................................................................38 Symptoms of High or Low Blood Glucose........................................41 Help • C ONTOUR ® Test Strips — Use for blood glucose or control solution testing. Supplied in a handy bottle with an easy-to-open flip-top lid. For short simple instructions, a quick reference guide is also provided. It can be more convenient when traveling. * For information on compatible Medtronic devices, contact Medtronic Customer Service at 1-800-646-4633. CTS-103_CntrLINK_UG_Master_FpB4_v7.indd ifc2-1 Changing the Batteries ...................................................................42 Caring for the System .....................................................................43 Transferring Results to a Computer .................................................44 Technical Information ......................................................................45 Specifications ..................................................................................46 Warranty ........................................................................................48 Service and Supplies........................................................................50 Extras • BATTERIES—Use two 3-volt (DL2032 or CR2032) lithium batteries. Replace when necessary. 2/7/11 3:59:51 PM Important When the Send option on the CONTOUR LINK meter is set to ON: Important Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - If you need help, please contact the Bayer Diabetes Care Customer Service at 1-800-348-8100 Your CONTOUR ® L INK Meter: Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 2-3 Display Up/Down Scroll Buttons Memory Button Test Strip Port (On/Off, Memory Recall, Enter) Your CONTOUR ® Test Strip: Sample Tip: The end of the test strip where the blood is pulled in. Gray Electrode End: The end of the test strip that is inserted into the test strip port on the meter with the gray end facing up. Your Testing Tools Important Important Information Your MICROLET ®2 Lancing Device: Cocking End Release Button Lancet Holder Lancet Protective Cap Adjustable Endcap (FINGERTIPS) www.bayerdiabetes.com/us 2/7/11 3:59:51 PM The picture below shows all the symbols that will appear on your meter display. When the meter is off, press and continue holding the ▲ or ▼ button. All segments will be displayed and remain on while holding the button down for 10 seconds. Repeat as needed to compare your meter to the display shown below. The CONTOUR® LINK meter and MICROLET®2 lancing device are intended for self-testing of blood glucose by people with diabetes to monitor their blood sugar in whole blood. Your Meter Display While all characters are displayed, it is most important to verify that is fully displayed. If it is not, see Error Codes and Symbols (page 40). This may affect the way you see your results. Top area on the display presenting date and time. Indicates Send option Indicates beeper is turned on. is turned on. Displays the date format. Indicates an alarm has been set. Pre-meal result marker. Center area on the display that shows either your test result or any error codes. Control result marker. Post-meal result marker. or will appear if the meter is in 12 hour setup. Indicates the meter is ready to test. Results are displayed along with the preset units of measure. The 7 appears when viewing the number of results over the past 7 days. Average. Identifies Indicates the a test result batteries are low Indicates it is too cold as unique or and need to be or too hot for your Need Helpmeter ? Bayer Diabetes Care: 1-800-348-8100 different. changed. to test accurately. CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 4-5 The MICROLET®2 lancing device included in this kit is not intended for use on multiple patients by healthcare professionals. Neither the CONTOUR® LINK meter nor the MICROLET®2 lancing device or lancets should be used with more than one person due to the risk of infection. The meter and lancing device are for single patient use. Do not share them with anyone including other family members. Do not use on multiple patients. After first use, all parts of the CONTOUR® LINK kit are considered contaminated with body fluids (blood) and could potentially transmit infectious diseases, even after you have performed the recommended cleaning and disinfection process. Used test strips and lancets are possible biohazards and must be disposed of properly. Important Important Safety Instructions Important Safety Instructions Important Your Meter Display Always wash your hands thoroughly with soap and water after handling the meter, lancing device, or test strips. WARNING: • The meter and lancing device are for single patient use. Do not share them with anyone including other family members! Do not use on multiple patients!1, 2 • All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after you have performed cleaning and disinfection. For complete instructions on cleaning and disinfecting your meter and lancing device, please see page 18. www.bayerdiabetes.com/us 2/7/11 3:59:53 PM Programmed: Your CONTOUR LINK meter has been preset at the factory with the standard date and time. To change these settings or to use advanced meter features, such as meal markers, read through the Options section of your User Guide. Your CONTOUR LINK blood glucose meter is specific for glucose and has been referenced to plasma/serum values. Methods calibrated to plasma/serum can be 9% to 15% higher than the results of whole blood glucose assay methods. Your Meter Features Easy: The CONTOUR LINK blood glucose monitoring system is all about simplicity. You will notice its uncomplicated approach the first time you see it. Simple things like the use of three large buttons and a clear display are sure to make this your favorite meter right from the start. Automatic: You no longer have to worry about coding your meter or marking a control test result. The CONTOUR LINK meter does it automatically. It will even tell you when a test strip is under-filled. Makes Sense: You will find features asked for by customers just like you. Practical features like a fast test time, a very small blood sample size, and a simple testing procedure (No Coding TM technology!) make the CONTOUR LINK meter your meter. Convenient: Your CONTOUR LINK meter takes up about as much room in your pocket or bag as your key ring. The meter’s small size, sleek design, and ease of use allow you to take it everywhere. You will be likely to test more often, which can mean better control of your diabetes. “Talks” to Your Compatible Medtronic Device: Your CONTOUR LINK meter has the ability to automatically send your glucose result directly to your compatible Medtronic MiniMed Paradigm Insulin Pump. This eliminates the need to manually enter your blood glucose result into the insulin pump’s Bolus Wizard® Calculator, which calculates an estimated bolus to support your food intake or to correct a high blood glucose. Your CONTOUR LINK meter can also send your fingertip blood glucose result directly to your compatible MiniMed Paradigm or Guardian REAL-Time CGM System, eliminating the need to manually enter the result when calibrating the system. Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 6-7 Always keep the test strips in the original bottle. Tightly close the bottle immediately after removing a test strip. The bottle is specially designed to provide a dry environment for the test strips. Extended exposure to room humidity from leaving the bottle open or not storing the test strips in the original bottle will damage your test strips. Avoid excessive “milking” of your finger when forming a drop of blood and test immediately after forming the blood drop. DO NOT use a test strip that appears damaged or has been used. Test strips are for single use only. Important Important Things to Know Important Things to Know Important Your Meter Features IMPORTANT NOTE: Your meter has been preset and locked to display results in mg/dL (milligrams of glucose per deciliter). Test results in mg/dL will never have a decimal point. In some countries, the meters are preset to display units in mmol/L (millimoles of glucose per liter). Results in mmol/L will always have a decimal point. Check your display to ensure that results are being displayed in the expected units; if they are not, contact Bayer Diabetes Care Customer Service at 800-348-8100. Example: or IMPORTANT: When a low battery warning displays on the meter, replace the battery as soon as possible to avoid a test result not being stored in the meter memory. www.bayerdiabetes.com/us 2/7/11 3:59:53 PM Talking to Your Compatible Medtronic Device 1. Program your meter ID number into your compatible Medtronic device. The ID number is the serial number found on the left side of the back label of your meter. It is a 6-digit numeric or alphanumeric number (0–9, A–F); for example, 1204620 or B12B3C. See the User Guide for your Medtronic device for complete information on this step. 2. Set your meter to the same time and date as your Medtronic device (see page 27 in this User Guide). The Medtronic device can receive a glucose result only if you have entered your meter’s ID number into the device. Conversely, no one else’s insulin pump or continuous glucose monitoring system can receive your glucose result, unless your meter ID number has been entered into that device. The meter uses a wireless signal to send the blood glucose result to the Medtronic device. However, the Send option must be set to ON (see page 26) and the meter and Medtronic device must be within 4 feet of each other. If you are not using the link functionality on your Medtronic device, you may want to turn the Send option off to save battery power. Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 8-9 1. Have all the materials you will need ready before you begin testing. This includes your CONTOUR LINK meter, the CONTOUR test strips, and the MICROLET2 lancing device with MICROLET lancets. You may also need CONTOUR control solution to run a quality control check. 2. Read your User Guide and all instructional materials provided in your meter kit before testing. 3. Let the meter and test strips adjust to the temperature of the location where you are testing. Whenever the meter is moved from one location to another, allow 20 minutes for the meter to adjust to the temperature of that new location before performing a blood glucose test. Important Your CONTOUR LINK meter is already set with the Send option turned on. (To turn the option off, see page 26.) Every time the meter displays a new blood glucose test result, the result is automatically sent to your compatible Medtronic device. However, your Medtronic device will only accept the glucose result if the Meter Option in your device’s Utilities Menu is set to On and you have programmed the device with the meter’s ID (serial) number. Up to three different meter ID numbers, can be accepted. See your Medtronic device addendum that is included in your device box. Before You Begin Before You Begin Important First Things First: Talking to Your Compatible Medtronic Device 4. It is important not to use the test strips or control solution if the expiration date printed on the bottle label and carton has passed or if it has been six months (180 days) since you first opened the control solution bottle. It will help to write the six month discard date on the label in the area provided when you first open the control solution. 5. Before testing, always wash your hands thoroughly with warm soapy water and dry them well. www.bayerdiabetes.com/us 2/7/11 3:59:53 PM Read the insert for the M ICROLET 2 lancing device for complete instructions. Remove a test strip from the bottle. Tightly close the bottle lid immediately after you have removed the test strip. Before testing, always wash your hands thoroughly with warm soapy water and dry them well. Testing Remove the endcap from the M ICROLET 2 lancing device. Tightly close the bottle lid immediately after you have removed the test strip. Excess moisture could damage the test strip. Getting Ready to Test Rotate (do not remove) the protective cap on a lancet ¼ turn. Insert the lancet firmly until it comes to a full stop. This will “cock” the device. NOTE: You can also pull and release the cocking end to “cock” the device. Twist off the lancet cap. Be sure to save it for disposing of the used lancet. 10 NOTE: Check the expiration date. Make sure the test strip does not appear torn or damaged. Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 10-11 Hold the test strip with the gray end facing up. Insert the gray end into the test strip port on the meter. No need to enter a code! Check battery status. If battery shows low, see page 42. Testing Replace the device endcap. Getting Ready to Test Getting Ready to Test: The meter will turn on. A test strip with a flashing blood drop will appear, letting you know the meter is ready to test, and the Send arrow ( ) will show that the meter is set to send the result to your compatible Medtronic device. www.bayerdiabetes.com/us 11 2/7/11 3:59:53 PM Fingertip Testing — The depth of the puncture depends upon the adjustable endcap setting you choose and the amount of pressure applied to the puncture site. You should determine which combination works best. Immediately touch the Getting the Blood Drop Press the endcap firmly against the puncture site and press the blue release button. tip of the test strip to the drop of blood. The blood is pulled into the test strip through the tip. Testing Deep Puncture Testing Your Blood: Do not press the tip against the skin or place the blood on top of the test strip. Hold the tip of the test strip in the blood drop until the meter beeps. Wait a few seconds. Stroke your hand and finger towards the puncture site to form a drop of blood. Do not squeeze around the puncture site. After the beep, you will see the meter count down the five seconds until the test is complete and your result is displayed. Testing Your Blood Testing Shallow Puncture Getting the Blood Drop: Test immediately after you have formed a blood drop. 12 Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 12-13 www.bayerdiabetes.com/us 13 2/7/11 3:59:59 PM Testing Your Blood The test result will also be automatically stored in the meter memory. If you have set your meter to use the special marker options (see page 29), the markers must be selected while the result is still being displayed, before removing the strip or turning the meter off. NOTES: 1. A result of “LO” or “HI” will not be sent to the Medtronic device, even when the Send option is on. Results of 10-19 mg/dL will be sent to the Medtronic device; however the device will ignore these results (they will not be displayed). 2. Important: Always check the display on your Medtronic device to ensure that the glucose result shown agrees with the meter display. Stopping a Result While it is Being Sent If you want to stop the transmission of a result (if it has not been accepted by the Medtronic device in 5 seconds), press M. The transmission will be cancelled. Be aware that the result cannot be resent later. If you do NOT want to send a blood test result to your Medtronic device, you can turn off the Send option for a single test. You may want to do this if you do not want to create a wireless signal (for example, if you have been asked to turn off all electronic devices on an aircraft). 1. Insert a test strip into the meter to turn the meter on. Before you begin your test, press and hold the ▲ or ▼ key until “ ” is displayed. The displayed next to the date will disappear, indicating that the Send option is temporarily turned off. 2. Test your blood as usual. The result will not fl ash, indicating that it is not being sent. 3. When you turn the meter on to perform another test, the Send option will again be on (the will be displayed). Testing Turning off the Send option for a Single Test Result Turning off the Send option for a Single Test Result Testing Your test result will begin flashing to indicate that it is being sent to your Medtronic device. It will continue to flash for at least 5 seconds (up to 60 seconds), until the meter receives a message from the Medtronic device that the result has been received. If your result does not flash, check to be sure the Send option is turned on (see page 26). 3. Do not attempt to insert a new test strip until the display stops flashing. Doing so will cause the transmission to be stopped. 14 Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 14-15 www.bayerdiabetes.com/us 15 2/7/11 4:00:06 PM Testing Testing Your Blood • Do not change your medication based on CONTOUR LINK blood glucose results without the advice of your physician or healthcare professional. To turn your meter off, simply remove the test strip. Carefully dispose of the used test strip in an appropriate waste container. (The meter will automatically turn off after three minutes if you do not remove the test strip.) Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 16-17 Place the round protective lancet cap on a flat surface with the Bayer logo facing down. With the used lancet still in the lancing device, push the lancet needle completely into the middle of the exposed side of the cap. While (a) pressing the blue release button, (b) pull the blue cocking handle, and the lancet will drop into the container you have selected. Testing In one hand, hold the lancing device with your thumb on the grip indent, with your other hand, hold the gray endcap dial as shown, and gently snap off the endcap. WARNING • Test your blood again if your test result is below 50 mg/dL, above 250 mg/dL, or if you see “LO” or “HI” on the meter display. If your glucose level is still below 50 mg/dL, above 250 mg/dL, or shows as “LO” or “HI”, call your physician or healthcare professional immediately. NOTE: If the glucose result is still being sent to your Medtronic device, the meter will not turn off until the transmission is complete. 16 Removing the used lancet: Testing Your Blood Expected Values: Blood sugar values will vary depending on food intake, medication dosages, health, stress, or activity. Non diabetic expected values are 75 to 110 mg/dL fasting.1 You should consult with your healthcare provider for expected values specific to your needs. Dispose of the used lancet carefully to prevent injury or contamination to others. Do not reuse lancets. Use a new MICROLET® lancet each time you test. www.bayerdiabetes.com/us 17 2/7/11 4:00:07 PM Cleaning Your Meter Your CONTOUR® LINK system should be cleaned and disinfected as recommended. Supplies Necessary for Cleaning: Cleaning is the removal of visible dirt and debris, but does not reduce the risk for transmission of infectious diseases. Your CONTOUR® LINK system should be cleaned of dirt and debris as needed. > Paper towels Cleaning and Disinfection For more assistance call: 1-800-348-8100 1. If the meter is soiled, clean with a drop of mild detergent on a moist (not wet) paper towel. Do not allow cleaning solution to run into the meter through areas such as the data or strip ports or around the buttons. Wipe away any detergent residue and dry as necessary with a clean paper towel. Disinfecting Your Meter Supplies Necessary for Disinfecting: www.bayerdiabetes.com/us > Household bleach spray with 1.84% sodium hypochlorite More information can be found at: > Paper towels http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ ucm224025.htm http://www.cdc.gov/injectionsafety/Fingerstick-DevicesBGM.html > Cotton swabs > Timing device 1. Before disinfecting, if the meter is soiled it must be cleaned as described above in CLEANING YOUR METER. DO NOT SPRAY BLEACH DIRECTLY ON YOUR METER 2. To disinfect, spray a clean and dry paper towel with bleach spray until wet but not dripping. 18 Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 18-19 Testing Testing Disinfecting (if performed properly) reduces the risk of transmitting infectious diseases. It should be disinfected at least once a month or when contamination with blood is suspected or is visible and before anyone assists you with the testing of your blood glucose. > Mild detergent www.bayerdiabetes.com/us Cleaning and Disinfecting Your Meter Cleaning and Disinfection 19 2/7/11 4:00:11 PM Cleaning Your Lancing Device Supplies Necessary for Cleaning: WIPING CONTINUOUSLY, KEEP ALL METER SURFACES WET FOR 60 SECONDS. 1. If the MICROLET®2 is soiled, clean with a drop of mild detergent on a moist (not wet) paper towel. Wipe away any detergent residue and dry as necessary with a clean paper towel. Testing 3. Wipe all exposed surfaces of the meter until wet. Do not allow disinfecting solution to run into the meter through areas such as the data or strip ports or around the buttons. Data Port > Mild detergent > Paper towels Disinfecting Your Lancing Device Testing Disinfecting Your Meter (cont’d) Supplies Necessary for Disinfecting: Disinfecting Your Meter Buttons Test Strip Port 4. To disinfect the test strip port, moisten a cotton swab with bleach spray and wipe all strip port surfaces until wet. Again, do not allow disinfecting solution to run into the meter. KEEP ALL STRIP PORT SURFACES WET FOR 60 SECONDS, WIPING CONTINUOUSLY. > Paper towels > Cotton swabs > Timing device 1. Before disinfecting, if the lancing device is soiled it must be cleaned as described above in CLEANING YOUR LANCING DEVICE. 2. To disinfect, spray a clean and dry paper towel with bleach spray until wet but not dripping. 3. Remove the end cap and lancet if present. Cleaning and Disinfecting Your Lancing Device > Household bleach spray with 1.84% sodium hypochlorite 5. Dry all meter surfaces and test strip port using a clean paper towel if needed. 20 Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 20-21 www.bayerdiabetes.com/us 21 2/7/11 4:00:11 PM Disinfecting Your Lancing Device (cont’d) Control Solution Testing: 4. Wipe all exposed surfaces of the lancing device until wet. Use only Bayer’s CONTOUR® control solutions (Normal, Low, or High) with your CONTOUR meter. Using anything other than CONTOUR control solution could present incorrect results. WIPING CONTINUOUSLY, KEEP ALL LANCING DEVICE SURFACES WET FOR 60 SECONDS. Run a control test: • When using your meter for the first time; Testing Testing • When you open a new vial of test strips; • If you think your meter may not be working properly; or • If you have repeated unexpected blood glucose results. Disinfecting Lancing Device 5. Moisten a cotton swab with bleach solution and wipe all internal and external surfaces of the end cap until wet. WIPING CONTINUOUSLY, KEEP ALL END CAP SURFACES WET FOR 60 SECONDS. Tightly close the bottle lid immediately after you have removed the test strip. Excess moisture could damage the test strip. NOTE: Check the expiration and discard date. Make sure the test strip does not appear torn or damaged. Hold the test strip with the gray end facing up. Insert the gray end into the test strip port on the meter. Control Solution Testing Remove a test strip from the bottle. 6. Dry all lancing device surfaces and end cap with a clean paper towel if needed. 22 Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 22-23 www.bayerdiabetes.com/us 23 2/7/11 4:00:11 PM The meter will automatically recognize and mark ( ) the control result for you. Gently rock the control bottle before opening to ensure it is mixed well. Squeeze a small drop of control solution on a clean nonabsorbent surface (such as a piece of wax paper). Do not apply the control solution to your finger nor directly to the test strip from the bottle. Recap the bottle immediately. Compare your control test result with the Normal Control Range printed on the test strip bottle label or on the bottom of the test strip box. Control Solution Testing Immediately touch the tip of the test strip to t h e d ro p o f c o n t ro l solution. The solution is pulled into the test strip through the tip. Hold the test strip in the drop until the meter beeps. After the beep, you will see the meter count down five s e c o n d s until the test is complete and your control test result is displayed. Testing NOTE: The does not indicate the control test result is within the specified range. NOTE: Low and High control range values can be found on the bottom of the test strip box. If your control test result is out of range, do not use your meter for blood glucose testing until you resolve the issue. See “What You Should Do” on page 40. To turn your meter off, simply remove the test strip. The result will automatically be marked with and stored in the meter memory. Control results will not be included in your 14 day blood glucose average or in the 7 day total. They are also not sent to your Medtronic device (the result does not flash). Control Solution Testing Testing The meter will turn on. A test strip with a flashing blood drop will appear, letting you know the meter is ready to test. Carefully dispose of the used test strip. 24 Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 24-25 www.bayerdiabetes.com/us 25 2/7/11 4:00:14 PM Setting Your Options: Setting the Time: You can set your meter to display different options. The time will now appear on the display. The number in the hour position will be flashing. Press ▲ or ▼ until you reach the correct time. Options Setting the Send Option: The number in the minute position will now flash. Press ▲ or ▼ until you reach the correct minute. Press M to set. The AM or PM will now flash. Press ▲ or ▼ to choose AM or PM. Setting the Send Option The Send arrow ( ) will be displayed at the top of the display and the word “ ” will be flashing. Press M to set. This option controls whether you want to send your test results to your Medtronic device. The date will now appear on the display. The year will be flashing. Press ▲ or ▼ to reach the current year. Press ▲ or ▼ to choose whether to turn the Send option on or off. (If you are not using the link functionality on your Medtronic device, you may want to turn the Send option off to save battery power.) Press M to set. Press M to set. Setting the Date: The month will now flash. Press ▲ or ▼ to reach the current month. Press M to set. The day will now flash. Press ▲ or ▼ to set the day. Options NOTE: You can exit the Setup mode at any time by pressing and holding M for 3 seconds. All selections you have made up to that point will be saved. Press M to set. Setting the Time, Date, and Sound To get into the Setup mode, press and hold M for three seconds. A complete display will briefly appear, then the Send option will be displayed. Press M to set. 26 Need Help ? Bayer Diabetes Care: 1-800-348-8100 CTS-103_CntrLINK_UG_Master_FpB4_v7.indd 26-27 www.bayerdiabetes.com/us 27 2/7/11 4:00:22 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Modify Date : 2011:03:02 16:10:13-06:00 Create Date : 2011:03:02 16:10:13-06:00 Metadata Date : 2011:03:02 16:10:13-06:00 Format : application/pdf Title : untitled Document ID : uuid:47cc99eb-99ee-49b7-9870-4af615253ee3 Instance ID : uuid:b8c0c57e-5ef1-42a5-915c-0c46fb44d6e1 Producer : Acrobat Distiller 9.4.0 (Macintosh) Page Count : 15EXIF Metadata provided by EXIF.tools