Atoms Labs AHS8R Control Hub User Manual QSG SHC draft
Atoms Labs LLC Control Hub QSG SHC draft
Users manual
QUICK START GUIDE SYSTEM INTRODUCTION Gateway Smart wireless central home control / management center. KIT CONTENT x1 Gayway Adaptor DC12V/1A IP Camera Motion PIR Door / Window Sensor x1 x4 Sticky pad x1 x4 Screw x3 Sticky pad x1 Adaptor DC 5V/1 A Panic Remote Adaptor DC12V/1A NA Battery CR2032 Indoor Siren Wireless day / night portable motion alert indoor camera. Ethernet cable 2M x3 Battery AA 1.5V IP Camera Remove the insulating plastic Adaptor DC12V/1A Ethernet cable 2M x1 Adaptor DC 5V/1.5A On / Off Switch x1 Panic Remote Wireless multi-functional panic remote controller. x4 Screw x4 Battery AA 1.5V x1 Bracket x2 Screw Motion PIR Wireless portable / wallmount area motion alert sensor. x1 Battery CR2032 On / Off Switch Wireless appliance energy management power switch / signal repeater (single device) Indoor Siren Wireless portable / wallmount alert siren. Door / Window Sensor Wireless door / window access alert sensor. Adaptor DC12V/1A Serie No. Battery AA 1.5V x 3 GETTING STARTED Follow the APP wizard setup process to add the camera. (2) The power LED indicator becomes steady RED and you will hear the gateway box beep twice. This means the gateway box is ready for APP setup. You can continue to setup the camera and sensor(s) now. 2. Set up the IP Camera (1) Connect the IP Camera to your router via the Ethernet cable . (2) Plug in the power adapter and wait until both RED and GREED LED begin flashing. Note: DO NOT begin the APP setup process until both LEDs become steady on. OMGUARDSHC Note: The APP will search the available IP Camera in LAN area. If the camera you're setting doesn't appear in the searching list, please enter the camera ID (DID) and password manually. (1) Connect gateway box to your router via the Ethernet cable. Then plug in the supplied power cable. Note: The gateway box should be powered on and connected to the Internet at all times. Remove the insulating plastic (3) Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon and choose 'Camera' to add the device to system. 1. Connect the gateway box to the Internet (3) Launch 'OMGUARD SHC' APP. The APP will automatically search the available gateway box and brings up the system DID/password. If it is not shown, Please check the system DID on the bottom of the gateway box. Enter the system DID and default password 123456 manually. or Battery AA 1.5V x 4 Steady RED Installing the IP Camera: (1) Secure the camera stand on the stable surface. (2) Mount the camera into camera stand. Adjust the viewing angle and fix the camera tightly. OMGUARDSHC 3. Pair the Motion Sensor Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon and choose 'Motion Sensor' and to initiate the pairing process, following with pressing the pairing button located inside the battery compartment to complete the process. OMGUARDSHC Installing the Motion Sensor: (1) Place the motion sensor upward, facing the location to be monitored. The detection distance is up to 16 meteres. For maximum coverage, it is recommanded to place the motion sensor highup with its back against the corner of walls to ensure best detection coverage. 16 meters (2) Use the double-sided tape to fix the motion sensor. 4. Pairing the Power Switch Using the mounting screws: Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon and choose âPower Switch' and to initiate the pairing process, following with press/hold the front panel button until LED flashing blue. (1) Fix the first mounting screw directly onto the door / window frame (A). Place (hang) the larger piece on to the mounted screw, remove the battery compart ment cover to fix the second mounting screw (B). OMGUARDSHC To initiate the repeater function, press / hold the front panel button turned orange, following with pressing the pairing button on the device . (2) Open back cover of the small piece. Use the mounting screws to fix the back cover on the movable part of the door/window frame (C). Mount the senor onto the back cover. Slot (3) When it is finished, open the door or window to test if the sensor has been correctly installed. You'll receive an alert from the mobile device if the APP and sensor have been corrected installed. 5. Pairing the Door / Window Sensor Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon and choose 'Door Sensor' and to initiate the pairing process, following with removing and reinstalling the battery compartment cover to complete the process. OMGUARDSHC 6. Indoor Siren Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon and choose 'Siren' and to initiate the pairing process, following with pressing the pairing button inside the battery compartment to complete the process. Installing the Door/Window Sensor Using the double-sided tape: OMGUARDSHC (1) Apply the double-sided tape to the backs of the Door/Window sensor. Installing the Siren: (2) Select a location on the door/window. The large piece of the sensor should be fixed on the immovable frame of the door/window. Align the small piece to the large one. Fix the small piece on the movable part of the door/window frame. It is recommanded to install (wall-mount / place on flat surface) the Siren in a highly visible location with minimum obsticles near for maximum visual and sound alert deterrence in critical situations. A/C power option is available, choose a suitable power outlet location for the installation. (3) When it is finished, open the door or window to test if the sensor has been correctly installed. You'll receive an alert from the mobile device if the APP and sensor have been corrected installed. 7. Pairing the Remote Control List of triggered events from device(s) and playback from camera(s). Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon and choose 'Panic Remote' and to initiate the pairing process, following with press/hold the camera button until the LED flashing blue. OMGUARDSHC Events STATUS INDICATOR 8. APP Operation ON Display device status in realtime. Tap "Status" to refresh the status page. Status Setup groups of devices for instant function activation / deactivation. 1. Choose "+" to start a new "control". 2. Naming the control and select device(s). 3. Save. Scenario Example: "Motion PIR" (initator) > "Power Switch" (follower) > "Save". OFF Sensor Off Sensor Triggered Power Low Vandal Alert Delete Edit Mode Group Setup various scenarios for system to launch preconfigured settings governing the behaviour of lights, cameras and sirens. 1. Choose a device (initiator) from the list. 2. Choose "+" to add additional device (follower). Repeat to add additional device(s). 3. Save. Sensor On FCC Compliance Statement: This device complies with Part 15 of the FCC rules. Operation is subjected to the following two conditions: (1)this device may not cause harmful interference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off interference and on, the user is encouraged to try to correct the by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help If the camera system no longer functions or can no longer be repaired, it must be disposed of according to the valid statutory regulations. Disposal of spent batteries/accumulators: You are required by law (Battery Ordinance) to return all spent batteries and accumulators. Disposing of spent batteries/accumulators with common household waste is prohibited! Batteries/accumulators that contain hazardous substances are marked with the symbols on the side. These symbols indicate that it is prohibited to dispose of these batteries/accumulators in the household waste. The abbreviations for the respective heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead. You can return spent batteries and accumulators that can no longer be charged to the designated collection points in your community, outlets or wherever batteries or accumulators are sold. Following these instructions will allow you to fulfill the legal requirements and contribute to the protection of our environment! Products with CE Marking comply with EMC Directive (2004/108/EC); Low Voltage Directive (73/23/EEC); R&TTE (1999/5/EC); ROHS Directive (2011/65/EU) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms: EMC: EN 301 489 LVD: EN 60950 Radio: EN 300 328
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Format : application/pdf Title : QSG-SHC draft Metadata Date : 2014:11:05 18:01:01+08:00 Modify Date : 2014:11:05 18:01:01+08:00 Create Date : 2014:11:05 18:01:01+09:00 Creator Tool : Adobe Illustrator CS6 (Windows) Thumbnail Width : 256 Thumbnail Height : 136 Thumbnail Format : JPEG Thumbnail Image : (Binary data 12462 bytes, use -b option to extract) Instance ID : uuid:28dc7920-9767-46bd-b28f-7e73541e5bdf Document ID : xmp.did:807F54B9CF64E4119B5FCA39B3E98570 Original Document ID : uuid:5D20892493BFDB11914A8590D31508C8 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:7F7F54B9CF64E4119B5FCA39B3E98570 Derived From Document ID : xmp.did:7F7F54B9CF64E4119B5FCA39B3E98570 Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8 Derived From Rendition Class : proof:pdf History Action : saved, saved History Instance ID : xmp.iid:6243383C905DE411B690A1FC571F2378, xmp.iid:807F54B9CF64E4119B5FCA39B3E98570 History When : 2014:10:27 12:17:59+08:00, 2014:11:05 18:00:53+08:00 History Software Agent : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows) History Changed : /, / Manifest Link Form : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference Manifest Reference File Path : G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2330.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2327.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2328.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2329.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2326.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2325.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2322.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\HOME.png, G:\JSW Corp_天鉞\QSG\SHC\links\HOME.png, G:\JSW Corp_天鉞\QSG\SHC\links\HOME.png, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2319.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\HOME.png, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2319.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\HOME.png, G:\JSW Corp_天鉞\QSG\SHC\links\HOME.png, G:\JSW Corp_天鉞\QSG\SHC\links\HOME.png, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2318.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2317_02.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\CE.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\FCC.png, G:\JSW Corp_天鉞\QSG\WAPP-GI2IS\links\未命名.png, G:\JSW Corp_天鉞\Manual\image\16.png, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2319.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2319.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2319.PNG, G:\JSW Corp_天鉞\QSG\SHC\links\APP\IMG_2319.PNG Startup Profile : Print Has Visible Overprint : True Has Visible Transparency : True N Pages : 1 Max Page Size W : 296.999959 Max Page Size H : 419.999514 Max Page Size Unit : Millimeters Font Name : HelveticaNeue-Light, HelveticaNeue-Bold, MyriadPro-LightSemiCn, MyriadPro-SemiboldSemiCn, MyriadPro-SemiboldSemiCnIt, MyriadPro-It, AdobeMingStd-Light Font Family : Helvetica Neue, Helvetica Neue, Myriad Pro, Myriad Pro, Myriad Pro, Myriad Pro, Adobe 明體 Std Font Face : Regular, Bold, Light SemiCondensed, Semibold SemiCondensed, Semibold SemiCondensed Italic, Italic, L Font Type : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type Font Version : 001.002, 001.101, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.062;PS 2.000;hotconv 1.0.57;makeotf.lib2.0.21895, Version 6.002;PS 6.001;hotconv 1.0.57;makeotf.lib2.0.21895 Font Composite : False, False, False, False, False, False, False Font File Name : HelveticaNeue-Light.otf, HelveticaNeue-Bold.otf, MyriadPro-LightSemiCn.otf, MyriadPro-SemiboldSemiCn.otf, MyriadPro-SemiboldSemiCnIt.otf, MyriadPro-It_0.otf, AdobeMingStd-Light.otf Plate Names : Cyan, Magenta, Yellow, Black Swatch Groups Group Name : 明亮 Swatch Groups Group Type : 1 Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0 Swatch Groups Colorants Mode : RGB Swatch Groups Colorants Type : PROCESS Swatch Groups Colorants Red : 126 Swatch Groups Colorants Green : 49 Swatch Groups Colorants Blue : 142 Producer : Adobe PDF library 10.01 Page Count : 2 Creator : Adobe Illustrator(R) 16.0 For : graphic, Bounding Box : -808 -1240 1927 211 Container Version : 9 Creator Version : 16EXIF Metadata provided by EXIF.tools