Atoms Labs AHSS31 Passive infrared motion detector User Manual QSG SHC draft

Atoms Labs LLC Passive infrared motion detector QSG SHC draft

User Manual

QUICK START GUIDEKIT CONTENTSYSTEM  INTRODUCTION                             GETTING STARTED1. Connect the gateway box to the Internet         (1) Connect gateway box to your router via the Ethernet               cable. Then plug in the supplied power cable.       (2) The power LED indicator becomes steady RED and                you will hear the gateway box beep twice. This                             means the gateway box is ready for APP setup.       (3) Launch 'OMGUARD SHC' APP. The APP will               automatically search the available gateway box and               brings up the system DID/password. If it is not               shown,  Please check the system DID on the bottom               of the gateway box. Enter the system DID and default               password 123456 manually.              Note:  The gateway box should be powered on and                            connected to the Internet at all times.   You can continue to setup the camera and sensor(s) now.2. Set up the IP Camera        (1) Connect the IP Camera to your router via the               Ethernet cable .        (2) Plug in the power adapter and wait until both RED                and GREED LED begin ashing.             Note:  DO NOT begin the APP setup process until both                                                                                                                                        LEDs become steady on.Adaptor DC12V/1AAdaptor DC12V/1AAdaptor DC12V/1AAdaptor DC12V/1AEthernet cable 2MBattery AA 1.5V Battery AA 1.5V x 3   NASticky pad ScrewBattery  CR2032  Sticky padAdaptor DC 5V/1 A Battery  AA 1.5V or Battery  AA 1.5V x 4Bracket x 1Adaptor DC 5V/1.5Ax 1x 1x 3 x 4 x 4x 1 x 3 x 4x 1 x 4 x 1Battery  CR2032x 1Screwx 2ScrewGayway  IP CameraMotion PIR On / O SwitchDoor / Window     SensorIndoor SirenPanic RemoteSteady RED        (3) Launch the 'OMGUARD SHC' APP. Click the 'ADD'                icon           and choose 'Camera' to add the device to               system.               Follow the APP wizard setup process to add the                               camera.                     Note:  The APP will search the available IP Camera in                            LAN area. If the camera you're setting doesn't                            appear in the searching list, please enter the                            camera ID (DID) and password manually.     Installing the IP Camera:        (1) Secure the camera stand on the stable surface.        (2) Mount the camera into camera stand.  Adjust the               viewing angle and x the camera tightly.3. Pair the Motion Sensor        Launch the 'OMGUARD SHC' APP. Click the 'ADD'  icon                             and choose 'Motion Sensor' and             to initiate the         pairing process, following with pressing the pairing         button located inside the battery compartment to         complete the process.         Installing the Motion Sensor:        (1) Place the motion sensor upward, facing the location                to be monitored.  The detection distance is up to 16               meteres.              For maximum coverage, it is recommanded to place               the motion sensor highup with its back against the               corner of walls to ensure best detection coverage.        (2) Use the double-sided tape to x the motion sensor.OMGUARDSHCOMGUARDSHCOMGUARDSHCEthernet cable 2Mx 1GatewaySmart wireless central home control / management center.  Serie No.Door / Window SensorWireless door / window access alert sensor.  Indoor SirenWireless portable / wall-mount alert siren. Panic RemoteWireless multi-functional panic remote controller.IP CameraWireless day / night portable motion alert indoor camera.Motion PIR Wireless portable  / wall-mount area motion alert sensor.On / O Switch Wireless appliance energy management power switch / signal repeater (single device) Remove the insulating plasticRemove the insulating plastic16 meters?
4. Pairing the Power Switch       Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon                          and choose ‘Power Switch' and             to initiate the        pairing process, following with press/hold the front        panel button until LED ashing blue.       To initiate the repeater function, press / hold the front             panel button turned orange, following with pressing the       pairing button on the device .5. Pairing the Door / Window Sensor       Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon                               and choose 'Door Sensor' and             to initiate the        pairing process, following with removing and reinstalling        the battery compartment cover to complete the process.   Installing the Door/Window Sensor   Using the double-sided tape:        (1) Apply the double-sided tape to the backs of the               Door/Window sensor.         (2) Select a location on the door/window. The large               piece of the sensor should be xed on the immovable               frame of the door/window.               Align the small piece to the large one. Fix the small               piece on the movable part of the door/window                             frame.         (3) When it is nished, open the door or window to test               if the sensor has been correctly installed. You'll               receive an alert from the mobile device if the APP and               sensor have been corrected installed.FCC Compliance Statement: This device complies with Part 15 of the  FCC rules. Operation is subjected to the following two conditions: (1)this device may not cause harmful interference, and (2) this device must accept any  interferencereceived, including interference that may cause undesired operation.Products with CE Marking comply with EMC Directive (2004/108/EC); Low Voltage Directive (73/23/EEC); R&TTE (1999/5/EC); ROHS Directive (2011/65/EU) issued by the Commission of the European  Community.  Compliance with these directives implies conformity to the following European Norms:EMC: EN 301 489LVD: EN 60950Radio: EN 300 328If the camera system no longer functions or can no longer be repaired, it must be disposed of according to the valid statutory regulations. Disposal of spent batteries/accumulators:You are required by law (Battery Ordinance) to return all spent batteries and accumulators. Disposing of spent batteries/accumulators with common household waste is prohibited!  Batteries/accumulators that contain hazardous substances are marked with the symbols on the side. These symbols indicate that it is prohibited to dispose of these batteries/accumulators in the household waste. The abbreviations for the respective heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead. You can return spent batteries and accumulators that can no longer be charged to the designated collection points in your community, outlets or wherever batteries or accumulators are sold. Following these instructions will allow you to fulll the legal requirements and contribute to the protection of our environment!   Using the mounting screws:        (1) Fix the rst mounting screw directly onto the door /               window frame (A).  Place (hang) the larger piece on               to the mounted screw, remove the battery compart              ment cover to x the second mounting screw (B).        (2) Open back cover of the small piece. Use the               mounting screws to x the back cover on the               movable part of the door/window frame (C).              Mount the senor onto the back cover.        (3) When it is nished, open the door or window to test               if the sensor has been correctly installed.  You'll               receive an alert from the mobile device if the APP and               sensor have been corrected installed. 6. Indoor Siren       Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon                             and choose 'Siren' and              to initiate the pairing        process, following with pressing the pairing button        inside the battery compartment to complete the        process.   Installing the Siren:        It is recommanded to install (wall-mount / place on at         surface) the Siren in a highly visible location with         minimum obsticles near for maximum visual and sound         alert deterrence in critical situations.  A/C power option         is available, choose a suitable power outlet location for         the installation.7. Pairing the Remote Control        Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon                             and choose 'Panic Remote' and              to initiate the         pairing process, following with press/hold the camera                    button until the LED ashing blue.8. APP Operation       Display device status in realtime.  Tap "Status" to refresh        the status page.      Setup groups of devices for instant function activation /       deactivation.      1. Choose "+" to start a new "control".      2. Naming the control and select device(s).       3. Save.     Setup various scenarios for system to launch pre-     congured settings governing the behaviour of lights,           cameras and sirens.    1. Choose a device (initiator) from the list.    2. Choose "+" to add additional device (follower).  Repeat          to add additional device(s).    3. Save.    Example: "Motion PIR" (initator) > "Power Switch"     (follower) > "Save".OMGUARDSHCOMGUARDSHCOMGUARDSHCOMGUARDSHCSlotStatusScenarioEventsGroup112233ABC      List of triggered events from device(s) and playback from       camera(s). STATUS INDICATORON OFFSensor OnSensor TriggeredVandal AlertEdit ModeSensor OPower LowDeleteChanges or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

Navigation menu