Atoms Labs AWF33 1080P indoor PT IP Cam User Manual JSW QSG WAPP ESR V2 1

Atoms Labs LLC 1080P indoor PT IP Cam JSW QSG WAPP ESR V2 1

Users manual

Download: Atoms Labs AWF33 1080P indoor PT IP Cam User Manual JSW QSG WAPP ESR V2 1
Mirror Download [FCC.gov]Atoms Labs AWF33 1080P indoor PT IP Cam User Manual JSW QSG WAPP ESR V2 1
Document ID3228002
Application IDxMs4hQFG8WzYer0V/NqvKg==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize91.11kB (1138859 bits)
Date Submitted2016-12-14 00:00:00
Date Available2016-12-14 00:00:00
Creation Date2016-11-23 14:51:51
Producing SoftwareAdobe PDF library 10.01
Document Lastmod2016-11-23 14:51:51
Document TitleJSW_QSG_WAPP-ESR_V2.1
Document CreatorAdobe Illustrator CS6 (Windows)

1080P indoor PT IP Cam
AWF33
3a.Wireless Connection
QUICK START GUIDE
KIT CONTENT :
Pan/Tilt Wireless
Appcam
Camera Antenna
x1
x1
Power Adapter
Quick Start Guide
Ethernet cable
x1
x1
x1
Optional item for limited models:
- Motion PIR - Window/ Door Contact - Panic Remote
Note:
(1) In the Wi-Fi setting of your smart device. Choose the Wi-Fi router with
prefix of HD-xxxxxx (xxxxxx=Camera ID numbers). Enter the default
password 12345678 and save the settings.
(2) Launch the APP, tap
to add the camera.
(3) Tap (QR code icon) and scan the QR code label on the back of the camera
to bring up the DID information. Or tap "Search" to locate the camera.
(4) Enter the default password 123456 and save the settings.
(5) Later, APP will request user to modify default password to
private password .
3b.Wired Connection
For video recording, BE SURE TO use CLASS 10 memory card or above (not included). Other kinds of memory card
may cause unexpected results and should be avoided.
Steady ON
HARDWARE OVERVIEW
Panic Remote
Mag
(1) Make sure your smartphone is connected your Wi-Fi router.
(2) Connect the camera to the Wi-Fi router with an Ethernet cable.
(3) Launch the APP, tap the “Search” to locate the camera.
(4) Enter the default password 123456 and save the settings.
(5) Later, APP will request user to modify default password to private password .
Light Sensor
Lens
Reset
PIR
LAN Port
Micro SD Card Slot
Note:
Power LED
Microphone
Power
Antenna
Panic Remote
In soft AP mode, the GREEN LED long flashes once followed by 2 short flashes. In normal mode, the LED
is flashing in green. For more details, please refer to the user manual.
4. Wi-Fi Setting
SETUP THE CAMERA
4a.
1. APP Download
Advanced
Download and install the "OMGuard HD" APP to your device.
Enter Admin Password
(default 123456)
Choose the appropriate Wi-Fi
router on your local network
For iOS
2. Power up The Camera
For Android
Power on the camera and wait until the GREEN LED indicator becomes steady on. This process would
be finished within 45 seconds and make sure the LED is flashing in GREEN.
4b. The Camera will offline for around 40 seconds to reboot for Wifi connection. When camera
connects to Wi-Fi router correctly, the Green LED will stay ON.
4c. In the Wi-Fi setting on your smart device again, make sure the Wi-Fi router you are connecting
to is the same as the camera. If not, manually assign to it.
Note: If you fail to add the camera for several times, please press and hold the “Reset” button for 5 seconds to reset it.
Then follow steps 3a or 3b again.
APP INTRODUCTION
SETUP SENSOR PIR/MAG
Add Sensor Device
(3)-1
Carrier
Back
9:41 AM
Sensor Setup
Live View
(4)
Carrier
75%
9:41 AM
Back
Sensor Edit
Live-View
Camera List
(1) Tap
then choose
(2) In the advanced section, enter admin password default 123456.
(3) Select sensor setup, tap “+” to add sensor device.
(4) Name your device and tap”Save”.
(5) Tap “Camera Pan control” to calibrate the camera position, and save the settings
(5)
75%
Save
Carrier
Cancel
9:41 AM
Trigger Preset
75%
Save
Add Sensor
(1)
(1)-1
(2)
(3)
Advanced
Arm/Disarm
Sensor Name:
Front Door
- Make sure camera & sensor are in fixed position.
Enter Admin Password
(default 123456)
- Slide
Trigger Preset
Reset
Delete
Snapshot
Mute
Video Record
Information
to position camera angle.
Refresh
- Tap “save” to save setting and exit.
Camera Setting
Setup Camera Position
Add Camera
Return
Talking Button
POSITION YOUR CAMERA & SENSOR
Event Trigger Auto-Position
- When an intruder is detected, the camera can immediately and automatically position itself to
capture video image of the intruder as evidence. With every event, the camera will immediately
send out push notifications to your mobile device.
- If you move or relocate the camera, please recalibrate the camera position again.
Follow the steps below for Event Playback.
and then the
1. Tap
2. Select the time interval for the event list.
3. Tap to select the file for playback.
4. If you want to store the files in mobile device, tap
to download the file (Best while under
Wi-Fi enviornment due to larger high defination data size).
(2)
Mag
(1)
Camera rotate
to the scene
PIR
(1)-1
(3)
(4)
CAMERA INSTALLATION
1. Place the mounting bracket on the mount
ing surface as a pattern to mark the holes.
2. Drill the mounting holes and use the wall
plug screws to secure the bracket to the wall.
3. Fasten the camera to the bracket using the
tapping screws.
4. Hang the camera and plate onto the hanger
screws. Arrange cable properly so that it will
not block pan/tile operation.
MOTION DETECTION / CAMERA SETTING TIPS
For optimum detection, we suggest the camera is to be mounted 7 to 8 feet (2.1m to 2.4m) from the floor
, and:
• On a rigid vibration-free surface.
• So the expected movement of an intruder is across the fields of the detection pattern.
To avoid false alerts, please note this device is equipped with a PIR Motion Sensor that operates by
detecting temperature changes in the area in front of the device; Please avoid placing the device under
the following environments:
(1) Aiming the PIR at windows or glass doors.
(2) Where small animals may enter the detection area.
(3) Where a heat source (sunlight, incandescent light, car headlights, etc) may affect the motion sensor.
(4) Where sudden temperature changes inside or around the detection area caused by hot or cold wind
(fans, air conditioners, etc.).
FCC Compliance Statement: This device complies with Part 15 of the FCC rules. Operation is subjected to the following
two conditions: (1)this device may not cause harmful interference, and (2) this device must accept any
interferencereceived, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference wil
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help
Products with CE Marking comply with EMC Directive
(2014/30/EU); Low Voltage Directive (2014/35/EU); RED
(2014/53/EU); ROHS Directive (2011/65/EU) issued by the
Commission of the European Community. Compliance
with these directives implies conformity to the following
European Norms:
EMC: EN 301 489
LVD: EN 60950
Radio: EN 300 328
If the camera system no longer functions or can no longer be repaired, it must be disposed of according to the valid statutory regulations.
Disposal of spent batteries/accumulators:
You are required by law (Battery Ordinance) to return all spent batteries and accumulators. Disposing of spent batteries/accumulators with
common household waste is prohibited! Batteries/accumulators that contain hazardous substances are marked with the symbols on the
side. These symbols indicate that it is prohibited to dispose of these batteries/accumulators in the household waste. The abbreviations for the
respective heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead. You can return spent batteries and accumulators that can no longer be
charged to the designated collection points in your community, outlets or wherever batteries or accumulators are sold. Following these
instructions will allow you to fulfill the legal requirements and contribute to the protection of our environment!

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Format                          : application/pdf
Title                           : JSW_QSG_WAPP-ESR_V2.1
Metadata Date                   : 2016:11:23 14:51:51+08:00
Modify Date                     : 2016:11:23 14:51:51+08:00
Create Date                     : 2016:11:23 14:51:51+08:00
Creator Tool                    : Adobe Illustrator CS6 (Windows)
Thumbnail Width                 : 256
Thumbnail Height                : 172
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 10125 bytes, use -b option to extract)
Instance ID                     : uuid:8fdf8256-cd59-4cfa-a687-7558abdf0fe9
Document ID                     : xmp.did:BB697B3527B1E611BD108EF086F9479B
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:1d2e1819-b318-41ba-b743-87dad67fe5b6
Derived From Document ID        : xmp.did:F0ABE8F3CD65E611AD9FB9C5AFA0CE39
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:939D644CEC45E311BF40FCCBC46B3F76, xmp.iid:BB697B3527B1E611BD108EF086F9479B
History When                    : 2013:11:05 16:19:57+08:00, 2016:11:23 14:51:43+08:00
History Software Agent          : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows)
History Changed                 : /, /
Manifest Link Form              : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference
Manifest Reference File Path    : G:\JSW Corp_天鉞\QSG\WAPP-GI2IS\links\未命名.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\Battery AA 1.5V.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\CE.png, G:\JSW Corp_天鉞\Symbol_Icon_Logo_配件線圖\FCC.png, D:\Product Technical Document\WAPP-ESR\images\2016-06-02-17-48-17.png, D:\Product Technical Document\2016-06-01-16-17-12.png, C:\Users\user\Pictures\2016-05-17-16-20-35.png, D:\Product Technical Document\SAPP-ES\Android.jpg, D:\Product Technical Document\SAPP-ES\iOS.png
Startup Profile                 : Print
Has Visible Overprint           : True
Has Visible Transparency        : True
N Pages                         : 1
Max Page Size W                 : 29.699996
Max Page Size H                 : 21.000217
Max Page Size Unit              : Centimeters
Font Name                       : Calibri, HelveticaNeue-Light, Lato-Bold, Lato-Regular, MyriadPro-SemiboldSemiCnIt, MyriadPro-SemiboldSemiCn, MyriadPro-Regular, MyriadPro-It, SFUIText-Regular, SFUIText-Semibold
Font Family                     : Calibri, Helvetica Neue, Lato, Lato, Myriad Pro, Myriad Pro, Myriad Pro, Myriad Pro, SFUIText Regular, SFUIText Semibold
Font Face                       : Regular, Regular, Bold, Regular, Semibold SemiCondensed Italic, Semibold SemiCondensed, Regular, Italic, Regular, Semibold
Font Type                       : Open Type, Open Type, TrueType, TrueType, Open Type, Open Type, Open Type, Open Type, Unknown, Unknown
Font Version                    : Version 1.02, 001.002, Version 1.010; Western character set, Version 1.010; Western character set, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168
Font Composite                  : False, False, False, False, False, False, False, False, False, False
Font File Name                  : CALIBRI_1.TTF, HelveticaNeue-Light.otf, Lato-Bold.ttf, Lato-Regular.ttf, MyriadPro-SemiboldSemiCnIt.otf, MyriadPro-SemiboldSemiCn.otf, MyriadPro-Regular.otf, MyriadPro-It.otf, MyriadPro-Regular.otf, MyriadPro-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Group Name        : 明亮
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 60.000004
Swatch Groups Colorants Magenta : 90.000000
Swatch Groups Colorants Yellow  : 0.003099
Swatch Groups Colorants Black   : 0.003099
Producer                        : Adobe PDF library 10.01
Page Count                      : 3
Creator                         : Adobe Illustrator CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ACMYAWF33

Navigation menu