Attenti LPU-800 Local Pager Unit User Manual General notes

3M Electronic Monitoring, Inc. Local Pager Unit General notes

User Manual

Download: Attenti LPU-800 Local Pager Unit User Manual General notes
Mirror Download [FCC.gov]Attenti LPU-800 Local Pager Unit User Manual General notes
Document ID332951
Application IDVMpQwRoTwltAF9/iQSjXnw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize168.56kB (2106978 bits)
Date Submitted2003-06-17 00:00:00
Date Available2003-06-17 00:00:00
Creation Date2003-06-08 17:01:46
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2003-06-08 17:17:49
Document TitleGeneral notes:
Document CreatorAcrobat PDFMaker 5.0 for Word
Document Author: pc100

LPU-800
User Manual
Version 1.0
30/05/2003
ElmoTech Ltd
Version 1.0
Prepared by:
Elmo-Tech Ltd.
Corporate Headquarters
2 Rehov HaBarzel
P.O. Box 13236
Ramat HaChayal
61132 Tel Aviv
Israel
Tel: +972-3 – 6478871
Fax: +972-3 – 6478872
Visit us at: www.elmotech.com
© 2001, Elmo Tech Ltd. All rights reserved.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted
in any form or by any means, electronic, mechanical, photocopying, recording or
otherwise, for purpose other than the user’s manual, without prior permission of Elmo Tech
Ltd.
NO WARRANTY
The technical documentation is being delivered AS-IS, and ElmoTech Ltd. makes no
warranty as to its accuracy or use. Any use of the technical documentation or the
information contained therein is at risk of the user. Documentation may include technical or
other inaccuracies or typographical errors. ElmoTech Ltd. Reserves the right to make
change without prior notice
Page 2 of 13
ElmoTech Ltd
Version 1.0
TABLE OF CONTENTS
1.
2.
3.
4.
General notes: ........................................................................................................ 4
Screen layouts........................................................................................................ 5
1. Init 0..................................................................................................................................... 5
2. Init 1..................................................................................................................................... 5
3. Init 2..................................................................................................................................... 5
4. Normal ................................................................................................................................. 6
5. Message ............................................................................................................................... 6
6. Message read ....................................................................................................................... 7
7. Message option .................................................................................................................... 7
8. Track mode .......................................................................................................................... 8
9. Menu.................................................................................................................................... 8
10.
Beep Volume ................................................................................................................... 9
11.
Ring Options.................................................................................................................... 9
12.
Self Test......................................................................................................................... 10
States Diagram..................................................................................................... 11
FCC Notices ........................................................................................................ 12
LPU Unit Customer Information ............................................................................................. 12
Transmitter FCC Notices ......................................................................................................... 13
Page 3 of 13
ElmoTech Ltd
Version 1.0
1. General notes:
1. If a message is received and the user ignores it, the “mail box” icon will be
displayed on the LCD and LPU (If not in vibrate mode) will beep shortly every 30
seconds (3*(on=100msec, off =300msec)).
2. The LPU should check AMS sanity and if not received activate alarm.
3. The sanity message sent from the AMS will include system time and next sanity
time.
4. Any key pressed on the LPU will stop the alarm.
5. The LPU will support “find lost LPU” command from the AMS (It will beep, even if in
vibrate mode, upon reception of this message).
6. When going back to “normal display” and messages are pending the LPU will
display a message prompt as described in screen 5.
7. Each incoming message will get its own serial number so that the last received
message will
get the first number and the serial numbers of the previous
messages will be shifted to the left, i.e. 1->2, 2->3…9->10 & 10th (last) message will
be automatically deleted).
8. Each keystroke will generate the short buzz (200msec).
Page 4 of 13
ElmoTech Ltd
Version 1.0
2. Screen layouts
1. Init 0
JJJJJJJJJJJJJJJJJJJJ U
JJJJJJJJJJJJJJJJJJJJ
JJJJJJJJJJJJJJJJJJJJ
JJJJJJJJJJJJJJJJJJJJ D
Event
Time
Description
For 1 second beep & back-light on.
2. Init 1
Event
Time
Description
For 1 second and vibrate & back-light off.
3. Init 2
H ome
Fr ee
L t d .
Or
E l mo
Tech
L t d .
Event
Time
Description
For 2 seconds back-light on.
Page 5 of 13
ElmoTech Ltd
Version 1.0
4. Normal
02 / 11 / 02
21 : 12 : 34
Me n u
Event
Low Bat
Message
Description
Open menu (9).
Show first message in the buffer if available. *1
Show last message in the buffer if available. *1
Beep every 30 sec + icon blink. LPU counter of 5 minutes. If counter elapsed shutdown the LPU.
Switch to message menu.
5. Message
02 / 11 / 02
21 : 13 : 39
02
Me s s a g e s r e c e i v e d
Re a d
Ex i t
Event
Low Bat
Description
Go to Read display & Mute the receiving alarm.
Back to previous display & Mute the receiving alarm & turn on the reminder. (4)
Mute the receiving alarm & turn on the reminder.
Beep every 30 sec + icon blink. LPU counter of 5 minutes. If counter elapsed the LPU will be
shutdown.
Message
Notes:
*1 If the pager’s memory doesn’t contain any massages then LPU will display: “No Messages”.
Page 6 of 13
ElmoTech Ltd
Version 1.0
6. Message read
Ro
s i
n i
Op
na l d
Vo l k .
Is mi s U
ng l as t Zon e i s :D i
n g r o o m . F i n d h i m▼
t i on
03
Ex I t D
i mm e d i a t e l l y .
Op t i o n
03
▲
Ex i t D
Event
Description *1
Show message option menu (7).
Back to normal display (4).
If at the beginning of the message scroll back to the previous message else scroll up 2
lines.
If at the end of the message scroll to the next message else scroll down 2 lines.
Low Bat Beep every 30 sec + icon blink. LPUt counter of 5 minutes. If counter elapsed shutdown the LPU.
Message Display the envelope icon.
7. Message option
RoNa l d
Vo l k . I s m i s
>T r ac k i ng<
De l e t e
Se l e c t
Ba c k
el
Event
Low Bat
Message
Description
Select the option. *2
Back to message read display (6).
Scroll between the menu options. The option selected will be highlighted.
Beep every 30 sec + icon blink. LPUt counter of 5 minutes. If counter elapsed shutdown the LPU.
Show the envelope and alarm.
Notes:
*1 If the user doesn’t read all new messages then mail icon will appear on the LCD & the pager will
remind every 30-second.
*2 When current message will be deleted, the LPU will return to the Previous screen.
Page 7 of 13
ElmoTech Ltd
Version 1.0
8. Track mode
Tr ack
Z a l ma n
S i r ano . U
TX - 0 3 4 5 9
R a n g e : > > > > > > > ZZZZZZZ
Mu t e
Ba c k D
Event
Description
Change the button to “UnMute” and stop beeping. If the alarm mode is vibrate only the
default text will be “UnMute”.
Back to message option (7).
Note in Use.
Low Bat Beep every 30 sec + icon blink. LPUt counter of 5 minutes. If counter elapsed shutdown the LPU.
Message Tracked TX - beep (The length and frequency is a function of the range).
9. Menu
30 / 05 / 02
>Be ep
Ri ng
Se l e c t
11 : 42 : 55 U
V o l ume <
Op t i o n
▼
Ex i t D
30 / 05 / 02
>Se l f
11 : 42 : 55
▲
Tes t <
Ex i t
Se l e c t
Event
Low Bat
Message
Description
Select the emphasis sub menu (10 or 11 or 12).
Back to normal display (4).
Cyclic scroll through the menu options. Each selected menu item will be highlighted.
Beep every 30 sec + icon blink. LPUt counter of 5 minutes. If counter elapsed shutdown the LPU.
Go to menu message display.
Page 8 of 13
ElmoTech Ltd
Version 1.0
10. Beep Volume
30 / 05 / 02
1 1 : 42 : 5 5
>H i g h
b e e p v o l ume <
ol
L ow
b e e p v o l ume
Se l e c t
Ba c k
Event
Low Bat
Description
Select the options and back to the previous display (9).
Back to menu (9).
Cyclic scroll through the beep volume.
Beep every 30 sec + icon blink. LPUt counter of 30 minutes. If counter elapsed shutdown the
LPU.
Message Update the number of messages pending.
11. Ring Options
30 / 05 / 02
1 1 : 42 : 5 5 U
>R i n g<
V i b r a t e
▼
Se l e c t
Ba c k D
30 / 05 / 02
>R i n g
Se l e c t
1 1 : 42 : 5 5 U
V i b r a t e <▲
Ba c k
Event
Low Bat
Description
Select the options and back to the previous display (9).
Back to menu (9).
Cyclic scroll through the beep volume.
Beep every 30 sec + icon blink. LPUt counter of 30 minutes. If counter elapsed shutdown the
LPU.
Message Update the number of messages pending.
Page 9 of 13
ElmoTech Ltd
Version 1.0
12. Self Test
JJJJJJJJJJJJJJJJJJJJ U
JJJJJJJJJJJJJJJJJJJJ
JJJJJJJJJJJJJJJJJJJJ
JJJJJJJJJJJJJJJJJJJJ D
H i gh Be
L ow Bee
V i b
Ba c k
e p V o l ume
p V o l ume
r a t e
L i gh t
L P U HW V ER
SW V ER
xx . xx
yy . yy
Event
Description
Low Bat Beep every 30 sec + icon blink. LPUt counter of 30 minutes. If counter elapsed shutdown the
LPU.
Message Update the number of messages pending.
Notes:
Self-test (LCD backlight, buzzer high, buzzer low, Vibrator & display the SW & HW VER).
After “self- test” completion the LPU will return to normal screen (4).
Page 10 of 13
ElmoTech Ltd
Version 1.0
Back or Select
Beep
Volume
Screen
Up/Down
LPU MMI
Ring
Options
Screen
Up/Down
3. States Diagram
Select
Back or Select
Start-up
Screens
Menu
Screen
Auto
Exit
Select
Select
Back or Select
Normal
Screen
Self-test
Screens
Automatically
back after self test
Mute/UnMute
Delete
Up/Down
Exit
Message
Read
Screen
Options
Back
Option
Screen
Up/Down
Auto
Up/Down
On/Off
Switch
Up/Down
Menu
Track
Back
Tracking
Screen
Read
Rec. Event
Message
Screen
buttons allow the following operations:
* Up/Down
1. Overview the message content.
2. Overlook the message headers.
Exit
Page 11 of 13
ElmoTech Ltd
Version 1.0
4. FCC Notices
The LPU Unit Model 800 has been tested and found to comply with the limits of a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This device generates, uses, and can radiate radio
frequency energy and, if installed and used in accordance with the instruction, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this device does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to correct the interference
by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could void the
user’s authority to operate the equipment.
LPU Unit Customer Information
The LPU Unit complies with FCC part 68 Rules. On the bottom panel of this equipment is a label that
contains, among other information, the FCC Number and Ringer Equivalence Number (REN is 1.0 B).
If the LPU Unit is not operating properly it may cause harm to the telephone network and the telephone
company will notify you in advance that temporary discontinuance of service may be required. If advance
notice is not practical, you will be notified as soon as possible. Also, you will be advised of your right to
file a compliant with the FCC.
The Telephone Company may make changes in its facilities, equipment, operations or procedures that
could affect the operation of the equipment. If this happens the Telephone Company will provide advance
notice in order for you to make necessary modifications to maintain uninterrupted service.
The LPU Unit installation is described in the installation chapter. Connection to Telephone Company
provided coin service is prohibited. Connection to party lines service is subject to state tariffs.
Page 12 of 13
ElmoTech Ltd
Version 1.0
Transmitter FCC Notices
The TXMTR Model 500 complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
This device has been tested and found to comply with the limits of the Class B digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This device generates, uses and can radiate radio frequency energy
and, if installed and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation.
If this device does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna
•
Increase the separation between the equipment and the receiver.
•
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could void the
user’s authority to operate the equipment.
Page 13 of 13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2003:06:08 17:17:49+02:00
Create Date                     : 2003:06:08 17:01:46+02:00
Page Count                      : 13
Creation Date                   : 
Mod Date                        : 
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : pc100
Metadata Date                   : 
Creator                         : pc100
Title                           : General notes:
Page Mode                       : UseNone
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LSQ-LPU-800

Navigation menu