Attenti SBU2000318 2TRACK BASE UNIT 318 MHz User Manual

3M Electronic Monitoring, Inc. 2TRACK BASE UNIT 318 MHz Users Manual

Users Manual

Download: Attenti SBU2000318 2TRACK BASE UNIT 318 MHz User Manual
Mirror Download [FCC.gov]Attenti SBU2000318 2TRACK BASE UNIT 318 MHz User Manual
Document ID1515824
Application IDJsNEBloOsKOM0EmxWBsjDA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize20.46kB (255697 bits)
Date Submitted2011-08-03 00:00:00
Date Available2011-08-03 00:00:00
Creation Date2011-06-27 13:13:58
Producing SoftwareNitro PDF PrimoPDF
Document Lastmod2011-06-27 13:13:58
Document TitleMicrosoft Word - Installation Instructions for SBU2000 Unit
Document CreatorPrimoPDF http://www.primopdf.com
Document Author: Aradd

SBU2000 / 2Track base unit
Installation and Operation Guide
Information in this documentation is subject to change without notice
and does not represent a commitment on part of Elmo-Tech Ltd. The
software described in this document is subject to the license agreement
that is included with the product, which specifies the permitted and
prohibited uses of the product. Any unauthorized duplication or use of
this documentation, in whole or in part, in print, or in any other storage
or retrieval system is prohibited.
No part of this publication may be reproduced, transmitted, transcribed,
stored in a retrieval system, or translated into any language in any form
by any means for any purpose other than the purchaser’s personal use
without the permission of Elmo-Tech Ltd.
© 2002-2010 Elmo-Tech Ltd. All rights reserved.
Unless otherwise noted, all names of companies, products, street
addresses, and persons contained herein are part of a completely
fictitious scenario and are designed solely to document the use of an
Elmo-Tech product.
Contact Us
Corporate Headquarters
Elmo-Tech Ltd.
2 Ha-Barzel St.,
P.O. Box 13236,
61132 Tel Aviv, Israel
Tel: 972-3-7671800
Fax: 972-3-7671801
U.S.A Customers, call 1-800-313-1483
E-mail: contact@elmotech.com
Visit us at: www.elmotech.com
Table of Contents
Installation Instructions for the Electronic
Monitoring System
1. SBU2000 Monitoring Unit Placement
In order to install the Electronic Monitoring System, you will need to find the best
location for the SBU2000 Monitoring Unit. The ideal location for the SBU2000
Monitoring Unit is as close as possible to the center of the house.
The SBU2000 Monitoring Unit should be placed on a flat horizontal surface, at
least 3 feet off the ground and at least 1 foot away from the wall. The SBU2000
Monitoring Unit should be in an open area away from other electrical appliances,
personal computers, laptops or metal objects.
2. Installing the SBU2000 Monitoring Unit
In order to install the SBU2000 Monitoring Unit, perform the following steps:
1. Disconnect the telephone cord from the wall telephone socket and plug it into
the Phone socket, located on the rear panel of the SBU2000 Monitoring Unit.
2. Connect one end of the supplied telephone cord into the Line socket, located
on the rear panel of the SBU2000 Monitoring Unit, and then connect the other
end of the same cord into the wall telephone socket.
3. Connect the appropriate end of the power adapter cord into the Power socket
located on the rear panel of the SBU2000 Monitoring Unit.
4. Connect the power adapter into a wall power socket. The SBU2000
Monitoring Unit makes an audible beeping sound and then runs through a
series of initialisation tests to check that everything is in order.
5. After completing the initialisation tests successfully the SBU2000 Monitoring
Unit beeps again and the left and right external LED indicators, located on the
rear panel of the SBU2000 Monitoring Unit are turned on. This indicates that
the SBU2000 Monitoring Unit is in a working state and has automatically
switched to standby mode.
3. Installing the 2TRACK
Installing the 2TRACK system involves:
1. Collecting the appropriate installation equipment and tools
2. Verifying that the Offender is registered in the E3-MWS software
3. Activating the 2TRACK Tracker unit
a. Installation Equipment
The kit of installation equipment includes the following items:
1. Tracker unit with carrying pouch and power adapter
2. Transmitter with strap holder
3. Locking clips
Warning: The Tracker unit’s battery must be
fully charged.
Verify the battery’s status by plugging the
charger into the Tracker unit and removing it.
The Tracker unit’s screen displays a power bar
to indicate the charge level of the battery.
b. Installation Tools
You will also need the following installation tools:
1. Manual Reset Device (MRD) – for activating the Transmitter
2.
Strap locking tool – for locking the Transmitter
3.
0.2” (5mm) flat head screwdriver – for opening the locking clip
4.
Snake eye screwdriver – for changing the straps of the Transmitter
c. Offender Information in the E3-MWS
Verify the following Offender details in the E3-MWS software application:
1. Offender’s name and address
2. Offender’s program type – 2TRACK Active
3. Equipment serial numbers – these must match the serial numbers on
the equipment you are planning to activate:
a. Tracker unit serial number
b. Transmitter serial number
Note: The relevant serial numbers are visible
on the back or side of each equipment item.
 Tracker unit SIM card details
For more information about working with the E3-MWS system, refer to the E3MWS Monitor Operator’s Manual.
4. Place 2TRACK in SBU2000 Unit
The SBU2000 unit device used to recharge the 2TRACK and transmit all GPS
location information, violation information, and house arrest status. It also
monitors the Ankle Bracelet when the 2TRACK is placed in the base unit
(docked).
5. Installation Manual for bracelet unit
Bracelet
To Attach the Bracelet
1. Match the Bracelet serial number on the Bracelet case to the number on
the Bracelet serial number in the hardware list in PCE. The ankle
transmitter and strap will be shipped unattached. You must insert one end
of the strap into the transmitter and push the locking pins into place. Make
sure that the locking pins are flush with the case. Measure the strap to the
offender’s leg and cut the strap to fit around the offender’s ankle. You
should size the strap so that it allows approximately ¼ inch of space
between the offender’s leg and the strap to ensure comfort.
2. Once you have the strap attached, push the locking pin through the holes
on the bracelet and into the strap until it locks into place
3. Make sure the locking pin is pushed far enough so that the top of the pin is
flush with the bracelet case
To Remove the Bracelet
1. Cut the strap
2. Using the screwdriver provided, turn the right locking pin counter
clockwise and the left locking pin clockwise to remove
3. Lift each side of the pin up from the strap and remove. Slide both ends of
the strap out of its channel. Dispose of the strap
4. Clean the bracelet with mild detergent. Rinse, dry, and return to your
inventory.
Downloading the Curfew Schedule
Once the monitoring system has been installed, perform the following:
1. Verify that the right LED located on the rear panel of the SBU2000
Monitoring Unit is constantly on and not flashing.
2. Using a mobile phone, call the monitoring center personnel and ask them to
perform a manual download.
10
6. FCC Notices
The SBU2000 complies with Part 15 of the FCC Rules. Operation is subject
to the following conditions:
1) This device may not cause harmful interference and
2) This device must accept any interference received, including interference
that may cause undesired operation.
3) Changes or modifications not expressly approved by Elmo Tech Ltd could void
the user’s authority to operate the equipment.
ATIS/ACTA Customer Information
This equipment, Smart Base Unit, model: SBU x000yyy (1), complies with
Part 68 of the FCC Rules and the requirements adopted by the ACTA. On the
bottom panel of this equipment is a label, that contains among other
information, a product identifier in the format US: LSQAL01BSBx000yyy. If
requested, this number must be provided to the Telephone Company.
This equipment is designed for connection to the telephone network using an
RJ-11 connector, which is Part 68 compliant. See Installation Instructions for
details.
The REN is used to determine the number of devices that may be connected to
a telephone line. Excessive RENs on a telephone line may result in the devices
not ringing in response to an incoming call. In most but not all areas, the sum
of RENs should not exceed five (5.0). To be certain of the number of devices
that may be connected to a line, as determined by the total RENs, contact the
local telephone company. The REN for Smart Base Unit, model: SBU
x000yyy, is 0.1B.
If the Smart Base Unit, model: SBU x000yyy, causes harm to the telephone
network, the Telephone Company will notify you in advance that temporary
discontinuance of service may be required. If advance notice is not practical,
you will be notified as soon as possible. Also, you will be advised of your right
to file a compliant with the FCC if it is necessary.
11
The Telephone Company may make changes in its facilities, equipment,
operations or procedures that could affect the operation of the equipment. If
this happens the telephone company will provide advance notice in order for
you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with the Smart Base Unit, model: SBU x000yyy, for
repair or warranty information please contact: Pro Tech Monitoring, lnc., 1838
Gunn Highway, Odessa, FL 33556, Phone 888.67.SMART, FAX
813.749.5474. If the equipment is causing harm to the telephone network, the
telephone company may request to disconnect the equipment until the problem
is resolved.
The Smart Base Unit, model: SBU x000yyy, installation is described in
Section 2 of the Smart Base Unit, model: SBU x000yyy, Maintenance
Manual. Connection to Telephone Company and providing coin service is
prohibited. Connection to party lines service is subject to state tariffs.
(1) x = 1 digit number that represents the SBU model's mechanical design.
yyy = 3 digit number that represents the SBU model's RF related
characteristics.
Caution:
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to the instructions
12

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 12
Producer                        : Nitro PDF PrimoPDF
Create Date                     : 2011:06:27 13:13:58-03:00
Modify Date                     : 2011:06:27 13:13:58-03:00
Title                           : Microsoft Word - Installation Instructions for SBU2000  Unit
Creator                         : PrimoPDF http://www.primopdf.com
Author                          : Aradd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LSQ-SBU2000318

Navigation menu