Atwood Mobile Products 10 E Users Manual
10e 1c3af2ae-e334-4e43-9c5c-6c45e26413f8 Atwood Mobile Products Water Heater 10-E User Guide |
2015-02-06
: Atwood-Mobile-Products Atwood-Mobile-Products-10-E-Users-Manual-500545 atwood-mobile-products-10-e-users-manual-500545 atwood-mobile-products pdf
Open the PDF directly: View PDF .
Page Count: 9
Download | |
Open PDF In Browser | View PDF |
LITERATURE NUMBER MPD 93755 L.P. GAS WATER HEATER 4 - 6 - 10 GALLON 9 Models 4-E & 10-E ENGLISH, FRANCAIS •Installation •Operation •Maintenance (et Canada) Effective 11.29.07 This water heater design has been certified by the Canadian Standards Association for installation in recreation vehicles. This water heater is not for use in marine applications. ............................................1 DIMENSIONS ..........................................................1 WEIGHT ................................................................1 SAFETY INFORMATION ..................................................................2-4 Water Heater GENERAL INSTALLATION ..............................................2-3 WATER HEATER SERVICE CALLS & QUESTIONS Location and phone numbers of qualified Service Centers can be found at our website http:/www.atwoodmobile.com or call 574-264-2131 to have a Service Center List mailed. Wiring Cutout Chart Pressure - Temperature Relief Valve Consumer Safety Warnings ..............................................................3 How to Operate Your Water Heater ..................................................3-4 Maintenance and Care Instructions ..................................................4-5 Preventative Maintenance ................................................................5 Winterizing (Flushing) Instructions ....................................................5 Pressure-Temperature Relief Valve ......................................................5 Flushing to Remove Unpleasant Odor ..................................................5 SAFETY ALERT SYMBOLS Safety Symbols alerting you to potential personal safety hazards. Obey all safety messages following these symbols. WARNING avoid possible injury or death MODEL IDENTIFICATION CAUTION avoid possible injury and/or property damage 1-12 ..........................................................................6-7 ....................................................................8 Water Heater WARRANTY ..............................................................16 FIGURES PART IDENTIFICATION Installation and service must be performed by a qualified Service Technician, Service Center, OEM or Gas Supplier. EXPLANATION OF MODEL NUMBER (EXAMPLE) G C H 6 AA - 10 E/P Electronic Ignition or Pilot Relight Revision (NUMBER) Heating Element (SCREW-IN OR BOLT-ON) 4 - 6 - 10 gallon capacity Engine Heat Exchange Combination Gas and AC Electric Gas (PROPANE) WARNING FIRE OR EXPLOSION • If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. - IF YOUR MODEL NUMBER IS NOT LISTEDOlder revision numbers may be 3, 4, 6, 7, 8 or 9 (_ _ _ _ _ - X _) ➤ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Regardless of your revision number the current instructions are still generally applicable to your unit. If you have questions contact your dealer, an Atwood Service Center or the Atwood Service Department. WHAT TO DO IF YOU SMELL GAS • Evacuate ALL persons from vehicle. • Shut off gas supply at gas container or source. • DO NOT touch any electrical switch, or use any phone or radio in vehicle. • DO NOT start vehicle’s engine or electric generator. • Contact nearest gas supplier or qualified Service Technician for repairs. • If you cannot reach a gas supplier or qualified Service Technician, contact the nearest fire department. • DO NOT turn on gas supply until gas leak(s) has been repaired. MODEL NUMBER CLARIFICATION TYPE 4 GAL Pilot Ignition G4-7 Electronic Ignition Pilot Relight Heat Exchange Electronic Ignition Combination Gas/Electric 6 GAL 10 GAL G6A-7 GC6AA-8P G10-2 GC10A-2 GC6AA-8 GH6-7 G10-2P GC10A-2P G6A-8E GCH6A-10E G10-3E GCH10A-4E GC6AA-10E GH6-8E GC10A-4E GH10-3E P IN MODEL # - SEE MODEL CLARIFICATION ABOVE H IN MODEL # - SEE MODEL CLARIFICATION ABOVE E IN MODEL # - SEE MODEL CLARIFICATION ABOVE C IN MODEL # - SEE MODEL CLARIFICATION ABOVE DIMENSIONS ALL MODEL 6 GALLON 10 GALLON 1 WIDTH HEIGHT 16˝ 16˝ 12.5˝ 15.5˝ SHIPPING WT. 6 GALLON 10 GALLON 25 lbs 32 lbs • When a cord and plug connection to the power supply are used on water heater, power cord must be UL listed as suitable for damp locations, hard or extra hard usage. It must be a flexible cord such as type S, SO, ST, STO, SJ, SJT, SJTO, HS or HSO cord as described in National Electrical Code, ANSI/NFPA 70. The length of external cord to water heater, measured to face of attachment plug, shall be no less than 2 feet nor more than 6 feet. Supply cord must be a minimum of 14 AWG and attachment plug must be rated at 15 amps. CRITICAL INSTALLATION WARNINGS • Install in recreation vehicles only. RV’s are recreation vehicles designed as temporary living quarters for recreation, camping, or travel use having their own power or towed by another vehicle. • All combustion air must be supplied from outside the RV, and all products of combustion must be vented to outside the RV. • DO NOT vent water heater with venting system serving another appliance. • DO NOT vent water heater to an outside enclosed porch area. • Protect building materials from flue gas exhaust. • Install water heater on an exterior wall, with access door opening to outdoors. • DO NOT modify water heater in any way. • DO NOT alter water heater for a positive grounding system. • DO NOT HI-POT water heater unless electronic ignition system (circuit board) has been disconnected (DC Hi-Pot). • DO NOT use battery charger to supply power to water heater even when testing. CAUTION ELECTRICAL DAMAGE • Label all wires before disconnecting when servicing controls. • Verify proper operation after servicing. ELECTRONIC IGNITION NOTE: It is recommended unit be connected directly to a 12V DC battery or to filtered side of an AC/DC converter. Avoid connections to unfiltered side of an AC/DC converter whenever possible. Use a minimum of 18 gauge wire, UL and CSA listed. 1. Refer to Wiring Diagram (FIG 12). Install remote switch in a convenient location. Position wall plate with letters up. Before making connections turn switch OFF. 2. Install wires see FIG 10 & 11. - FOLLOW ALL APPLICABLE STATE AND LOCAL CODES IN THE ABSENCE OF LOCAL CODES OR REGULATIONS, REFER TO CURRENT STANDARDS OF: USA AND CANADA • Recreation Vehicles ANSI A119.2/NFPA 501C. • National Fuel Gas Code ANSI Z223.1 and/or CAN/CGA B149 Installation Codes • Federal Mobile Home Construction & Safety Standard, Title 24 CFR, part 3280, or when this Standard is not applicable, the Standard for Manufactured Home Installations (Manufactured Home Sites, Communities and Set-Ups), ANSI A255.1 and/or CAN/CSA-Z240 MH Series, Mobile Homes. • National Electrical Code ANSI/NFPA No. 70 and/or CSA C22.1 • Park Trailers A119.5 • CSA standard Z240 RV Series, Recreational Vehicle. PILOT RELIGHT - FIG 12 1. Install unit according to GENERAL INSTALLATION instructions. 2. Refer to Wiring Diagram. Use 18 gauge wire, UL/CSA listed. 3. Read PILOT & PILOT RELIGHT OPERATIONS. HEAT EXCHANGE MODELS - FIG 5 1. Push a 5/8˝ diameter coolant system hose (5-A) [with SAE 053 A Type “E”clamp attached] onto heat exchanger tube (5-B) making a tight connection. 2. Spread hose clamp and slide toward heat exchange unit past annular groove (5-C) and release. 3. Continue to HOW TO OPERATE YOUR WATER HEATER and/or Electronic Ignition OPERATION. GENERAL INSTALLATION This is a common installation for water heaters. There are other approved methods such as Baggage Compartment (MPD 90093) and Flush Mount (MPD 93948) installations. Consult with your Field Auditor, Account Manager, or the Atwood Service Department if you have additional questions. 1. Locate water heater on floor of coach before erecting side walls. The water heater tank must be permanently supported at the same level as the bottom of sidewall cutout (by the floor or a raised floor) FIG 2. Provide adequate clearance at rear of unit for service of water connections. 2. To install water heater on carpeting, you must install appliance on a metal or wood panel that extends at least three inches beyond the full width and depth of appliance. 3. If the appliance is installed where connection or tank leakage will damage adjacent area, install a drain pan (which can be drained to out side of coach) under water heater. CONTINUE GENERAL INSTALLATION 4. Connect both 1/2˝ NPT water lines (FIG 2) hot water outlet female and cold water inlet female and 3/8˝ flared LP gas line to the water heater (FIG 9). a. Allow flexibility in water and gas lines so you can pull unit forward through wall one inch past skin. b. Seal gas line entrance opening (FIG 9) by sliding grommet (9-B) onto 3/8˝ tubing (9-D) before flaring tubing (9-E). Pull gas line and grommet through opening in housing (9-A). Connect flare fitting (9-C) and press grommet into opening. If gas line tubing is already flared, cut grommet on one side. Place split grommet over gas line and press it into opening. c. Always use pipe lubricant on threads when connecting hot and cold water couplings. A suitable plastic fitting is recommended. CAUTION WIRING All wiring must comply with applicable electrical codes. PRODUCT DAMAGE COMBINATION GAS/ELECTRIC MODELS are designed to operate with gas, electricity, or a combination of both. • Use electrical metallic tubing, flexible metal conduit, metal clad cable, or nonmetallic-sheathed cable with grounding conductor. Wire must have a capacity of 1400 watts or greater. The wiring method must conform to applicable sections of article 551 of National Electrical Code ANSI/NFPA 70. 1. Refer to Wiring Diagram (FIG 12). Make 120 VAC electrical connections from junction box on back of unit. a. Connect hot lead to (1) Black. b. Connect common lead to (2) White. c. Connect ground wire from electrical service to (3) green ground lead in junction box 3. • Do not lift, pull, push or misalign main burner tube (FIG 3-F). 5. Erect side walls and cut opening. See chart and Frame with 2x2 lumber (or equivalent). FIG 1. CUTOUT (FIG 1 & 2) CAPACITY Gallon 4-6 10 CUT OUT DIMENSION 1-A 1-B 12-5/8˝ 16-1/4˝ 15-3/4˝ 16-1/4˝ DEPTH 2-C 17-5/8˝ 20-5/8˝ MINIMUM CLEARANCE FROM COMBUSTIBLE CONSTRUCTION Sides: 0˝ Top: 0˝ Back: 0˝ Bottom: 0˝ 6. Bend all flanges 90˚ along scored lines (FIG 3-A). 7. To prevent water leaks caulk thoroughly around opening, including bend slots. Butyl Tape (1-1/3˝x1/8˝) may be substituted for caulking material. CAUTION PRODUCT DAMAGE • When using Romex® with a bare earth ground, take care to position ground wire so it does not contact the heating element terminals. 2 CONSUMER SAFETY WARNINGS 8. Push unit against caulking, secure 4-corner brackets (FIG 3-B) to coach with No. 8 - 3/4˝ round head screws (not furnished) or equivalent. Complete the installation by inserting the same type of #8 screws in the holes provided around the flange of the water heater housing. Check all gaskets, they must adhere to the pan creating an air tight seal. 9. Attach access door. a. Snap hinge pin (FIG 3-C) into clip (FIG 3-D). b. Slide cover (FIG 3-E) onto hinge pin. c. Slide hinge pin into cover, snapping into clip at same time (FIG 3-D). NOTE: To remove hinge pin, support access cover and apply force to corner of hinge pin. 10. Disconnect unit and its individual shut-off valve from gas supply line during any pressure testing of system in excess of 1/2 PSIG (3.4 kPa, 14˝ water column [W.C.]). DO NOT set inlet pressure higher than maximum indicated on rating plate of gas valve (13˝ W.C.). Isolate unit from gas supply line by closing its individual manual shutoff valve during any pressure testing ≤ 1/2 psig. WARNING EXPLOSION OR FIRE store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • Should overheating occur, or gas supply fail to shut off, turn OFF manual gas control valve to appliance, or turn gas OFF at the LP tank. On ELECTRONIC IGNITION MODEL turn operating switch to OFF position and remove red wire from left hand terminal of ECO switch or turn gas OFF at the LP tank. • Use with LP gas only. • Shut off gas appliances and pilot lights when refueling. • On PILOT RELIGHT MODELS, turn off the ignition module when refueling gasoline tanks or LP tanks. • Turn gas OFF at the LP tank when vehicle is in motion. This disables all gas appliances and pilot lights. Gas appliances must never be operated while vehicle is in motion. Unpredictable wind currents may be created which could cause flame reversal in the burner tube, which could result in fire damage. The thermal cut off fuse could also be unnecessarily activated resulting in a complete shutdown of the water heater requiring replacement of the thermal cut off. See maintenance of electronic ignition water heaters for further explanation of the thermal cut off. • LP tanks must be filled by a qualified gas supplier only. • DO NOT WARNING FIRE AND/OR EXPLOSION • DO NOT use matches, candles or other sources of ignition when checking for gas leaks. 11. Turn on gas and check water heater and all connections for gas leaks with leak detecting solution. 12. Fill water heater tank, check all connections for water leaks. PRESSURE-TEMPERATURE RELIEF VALVE WARNING HOW TO OPERATE YOUR WATER HEATER EXPLOSION • • • • CAUTION Valve is not serviceable, it must be replaced. Tampering with valve will result in scalding injury. Tampering with valve will void warranty. DO NOT place a valve, plug or reducing coupling on outlet part of relief valve. FIRE • Do not smoke or have any flame near an open faucet. If water heater has not been used for more than two weeks, hydrogen gas may form in water line. Under these conditions to reduce the risk of injury, open hot water faucet for several minutes at kitchen sink before you use any electrical appliance connected to hot water system. THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR ANY REASON OTHER THAN REPLACEMENT. This water heater is equipped with a tempera- ture and pressure relief valve (FIG 3-G) that complies with standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Systems, ANSI Z21.22. If hydrogen gas is present, you will probably hear sounds like air escaping through the pipe as water begins to flow. WARNING If you use a discharge line, do not use a reducing coupling or other restriction smaller than outlet of relief valve. Allow complete drainage of both valve and line. SCALDING INJURY • Do not tamper with pilot orifice. FOR REPLACEMENT PARTS: • DO NOT install anything less than a combination temperature-pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of product of listed equipment or materials, as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22. Valve must have a maximum set pressure not to exceed 150 psi. • Install valve into opening provided and marked for this purpose on water heater. • Installation must conform with local codes or in the absence of local codes, American National Standard for Recreational Vehicles, ANSI A119.2/NFPA 50IC. • For an external electrical source, ground this unit in accordance with National Electrical Code ANSI/NFPA70. CAUTION PRODUCT FAILURE • Do not operate without water in tank. PILOT OPERATION 1. Water heater may be equipped with a White Rodgers® or Robertshaw Unitrol® Control FIG 7. 2. Turn gas control valve knob (FIG 7-B) to OFF position. 3. Wait at least five minutes to allow accumulated gas in burner compartment to escape. FOR WHITE RODGERS® CONTROL (FIG 7) a. Turn lighting control knob (7-B) to PILOT position and hold against stop while lighting pilot burner. b. Allow pilot to burn thirty seconds then release lighting control knob. c. Turn lighting control knob (7-B) to ON position. d. If pilot does not remain lit, repeat operation allowing longer period before releasing lighting control knob. e. Set temperature selection lever (7-A) at mark between warm and hot position. f. Close access door. Your ATWOOD PILOT GAS WATER HEATER is now ready for operation. Continue to HOW TO OPERATE YOUR WATER HEATER 3 FOR A ROBERTSHAW UNITROL® (FIG 7) a. Turn lighting control dial (7-B) to PILOT position. b. Depress and hold reset push button (7-A) while lighting pilot burner (7-C). c. Allow pilot to burn thirty seconds before releasing reset push button. d. If pilot does not remain lit, repeat operation allowing longer period before releasing reset push button. e. Turn lighting control dial (7-B) to ON position. f. Set temperature control dial (7-C) at mid-point position between warm and hot. g. Close access door. GAS/ELECTRIC OPERATION. 4. For complete shut down and before servicing, turn gas control knob (FIG 7-B) to OFF position. When water heater is not in use set temperature control lever (White Rogers®) or dial (Robertshaw®) to lowest possible position. Location and phone numbers of qualified Service Centers can be found at our website http:/www.atwoodmobile.com or call 574-262-2655 to have a Service Center List mailed. The unit can be run in both gas and electric modes simultaneously for quick recovery. note: if the gas fails to ignite, the gas mode will lockout, but the lockout lamp will not illuminate since the electric mode is still operational. Should you notice slow recovery, indicating the gas is not working, turn the electric switch off. The lamp will then illuminate indicating a lockout has occurred on the gas side. Correct the problem and turn the switches back on. Read MAINTENANCE AND CARE INSTRUCTIONS. MAINTENANCE AND CARE INSTRUCTIONS SERVICE CALLS & QUESTIONS WARNING WARNING FIRE OR EXPLOSION SCALDING INJURY • Shut off gas supply at LP container before disconnecting a gas line. • Setting temperature control dial at a higher position will produce exces- • Keep control compartment clean and free of gasoline, combustible sively hot water. material, and flammable liquids and vapors. The temperature knob or lever is factory adjusted to its lowest dial setting. We recommended the mid-point position between warm and hot, as noted above. This will provide for energy efficient operation and sufficient hot water. Valves for reducing point of use temperature by mixing cold and hot water are available. Consult a licensed plumber or local plumbing authority. AFTERMARKET WATER HEATING ELEMENT DEVICES WARNING EXPLOSION / BURN INJURY • DO NOT alter water heater, it will void warranty. • DO NOT USE Aftermarket heating elements, they can lack critical safety 5. To Adjust Main Burner (FIG 4): 1. Loosen air shutter screw (4-A). 2. Slide air shutter (4-B) to right until some yellow appears in main burner flame. 3. Move air shutter (4-B) to left until yellow disappears. 4. Retighten air shutter screw (4-A). controls. • Use of Aftermarket heating elements can lead to an out of control heating of water tank and a catastrophic wet side explosion. The use of any aftermarket heating element devices may also result in damage to components or water heater. Atwood’s written warranty states - “failure or damage resulting from any alteration to our water heater is the owner’s responsibility”. Any alteration, like the addition of an aftermarket heating element device, will void the warranty. Read MAINTENANCE AND CARE INSTRUCTIONS ELECTRONIC IGNITION OPERATION 1. Refer to WIRING DIAGRAM FIG 12. Place remote switch in ON position. 2. If remote switch light stays on longer than 15 seconds, place remote switch in OFF position and wait 5 minutes. 3. Repeat step one. 4. For complete shut-down and before servicing: a. Place remote switch in OFF position. b. Remove red wire from left hand terminal of ECO switch (ECO to valve). 5. If heater fails to operate due to high water temperature, a lockout condition occurs (indicator light on). After water cools, reset switch in OFF position for at least 30 seconds, then turn to ON position. 6. If a lockout condition persists contact an Atwood Service Center. Read MAINTENANCE AND CARE INSTRUCTIONS & ELECTRONIC IGNITION MAINTENANCE GENERAL INFORMATION PILOT RELIGHT OPERATION ELECTRONIC IGNITION MAINTENANCE • LP and Water system must be turned on. • Have gas pressure tested periodically. Should be set at 11 inches of water column with three appliances running. • Drain water heater at regular intervals (at least one time during the year). • Drain water heater before storing RV for the winter or when the possibility of freezing exists. • Keep vent and combustion air grill clear of any obstructions. • Periodically, compare flame of main and pilot burners with FIG 5 and main burner adjustments in HOW TO OPERATE YOUR WATER HEATER. • When water heater is not in use set temperature control lever (White Rogers) or dial (Robertshaw) to lowest possible position. This will reduce the effects of low outdoor temperatures on calibration of temperature control mechanism. 1. Turn the switch located on the spark module to the ON position. 2. Read PILOT OPERATION instructions. 3. For complete shut down, turn lighting control knob on thermostat and spark module switch to the OFF position. Read MAINTENANCE AND CARE INSTRUCTIONS • The water heater comes factory-equipped with a fused circuit board, which will protect the circuit board from wiring shorts. If the fuse should activate, the water heater will not operate. Before replacing the fuse, check for a short external to the board. Once the short is corrected, replace the 2 amp fuse with a mini ATO style fuse. Do not install a fuse larger than 3 amps. • If the fuse is good and the unit is inoperative, check for excessively high voltage to the unit (more than 14 volts). • If the previous two steps did not solve the problem, check the thermal cut-off (FIG 3-I). The thermal cutoff is a device installed in the power supply line. This device will shut off electrical power and stop heater operation when activated. For example, if an obstruction within the flue tube should occur, as described in the Preventative Maintenance section, the burner flame/heat may contact the cutoff, resulting in a melting of the fuse element incorporated in the thermal cutoff. In order to restore power and proper operation of the water heater, the obstruction must be removed and the thermal cutoff must be replaced. GAS/ELECTRIC COMBINATION FUNCTION GAS OPERATION. When the gas switch is turned on, the unit will make three attempts to light. If for any reason there is no ignition, the unit will lockout and the red lockout lamp will illuminate. If the thermostat fails, the ECO will also lockout the unit, requiring resetting. Determine the reason for no ignition, correct it, and reset the gas ignition sequence by turning the switch off, then on. ELECTRIC OPERATION. When the electric switch is turned on, the relay at the rear of the unit will close and pass 110vac to the element. If the thermostat were to fail, the ECO will open and lockout the system. To correct, check the thermostat to assure good contact with the tank and reset the control by turning the electric switch off, then on. 4 A Pressure Temperature Relief Valve, dripping while the water heater is running, DOES NOT mean it is defective. During normal expansion of water, as it is heated in the closed water system of a recreation vehicle, the Pressure Temperature Relief Valve will sometimes drip. The Atwood water heater tank is designed with an internal air gap at the top of the tank to reduce the possibility of dripping. In time, the expanding water will absorb this air and it must be restored. Due to variations in water quality, the Pressure Temperture Relief Valve may have a shorter life and may need replacement within the water heater warranty period. If corrosion is detected, it will not be covered under warranty. PREVENTATIVE MAINTENANCE Spiders, mud wasps, and other insects can build nests in the burner tube. This will cause poor combustion, delayed ignition or ignition outside combustion tube. Listen for a change in burner sounds or in flame appearance from a hard blue flame to a soft lazy flame or one that is very yellow. These are indications of an obstruction in burner tube (FIG 4-C). Inspect and clean on a regular basis. a. Remove air shutter screw (FIG 4-A) and slide air shutter (FIG 4-B) down burner tube. b. Run a flexible wire brush down burner tube (FIG 4-D) until it is visible at end of burner tube. c. Vacuum burner where it enters combustion tube. d. Return air shutter to original position and replace screw. e. The orifice, burner tube and shutter must be aligned so that the shutter is not binding on the air tube. WARNING SCALDING INJURY • Turn off water heater before opening pressure-temperature relief HOW TO CLEAN PILOT MODELS - FIG 6 valve to establish air space. Storage water must be cool. 1. Check main burner orifice and pilot assembly for contamination (dirt, spider webs, etc.). 2. Clean main burner tube with small brush. 3. Main burner adjustment - open air shutter 1/4 way. 4. Low pilot flame. Check for contamination - if clean have the pilot orifice replaced. TO REPLACE THE AIR GAP FOLLOW THESE STEPS: 1. Turn off main water supply (the pump or water hook up source). 2. Let water cool or let run until cool. 3. Open the hot water faucet closest to the water heater. 4. Pull handle of pressure temperature relief valve straight out and allow water to flow until it stops. 5. Allow pressure temperature relief valve to snap shut; close faucet; turn on water supply. 6. Turn on water heater and test. • At least once a year manually operate pressure-temperature relief valve (FIG 10). When pressure-temperature relief valve discharges again, repeat above procedure. For a permanent solution, we recommend one of the following: • Install a pressure relief valve in cold water inlet line to water heater and attach a drain line from valve to outside of coach. Set to relieve at 100-125 PSI. • Install a diaphragm-type expansion tank in cold water inlet line. Tank should be sized to allow for expansion of approximately 15 oz. of water and pre-charged to a pressure equal to water supply pressure. These devices can be obtained from a plumbing contractor or service center. HOW TO CLEAN ELECTRONIC IGNITION MODEL 1. 2. 3. 4. 5. Check main burner orifice. Clean and adjust main burner. Main burner and valve manifold must align with each other Check electrode for cracked porcelain (FIG 4-E). Check electrode for proper gap - 1/8” between electrode and ground. 6. If module board functions intermittently, remove board and clean terminal block with pencil eraser (FIG 3-H). WATER HEATER TANK CARE WARNING SCALDING INJURY • Turn off water heater and allow time for water to cool before remov- ing drain plug to flush tank. WINTERIZING (FLUSHING) INSTRUCTIONS FLUSHING TO REMOVE UNPLEASANT ODOR To insure the best performance of your water heater and add to the life of the tank, periodically drain and flush the water heater tank. Before long term storage or freezing weather drain and flush the tank. 1. Turn off main water supply (the pump or water supply (the pump or water hook up source). 2. Drain Water Heater Tank by removing the drain plug. If the water flows sporadically or trickles instead of a steady stream of water, we recommend the following action; first open the Pressure Temperature Relief Valve to allow air into the tank and secondly, take a small gauge wire or coat hanger and poke through the drain opening to eliminate any obstructions. 3. After draining the tank, because of the placement of the Drain Plug, approximately two quarts of water will remain in the tank. This water contains most of the harmful corrosive particles. To remove these harmful corrosive particles flush the tank with either air or water. Whether using air or water pressure, it may be applied through the inlet or outlet on the rear of the tank or the Pressure Temperature Relief Valve. (If using the Pressure Temperature Relief Valve the Support Flange must be removed). The pressure will force out the remaining water and the corrosive particles. If you use water pressure, pump fresh water into the tank with the assistance of the on-board pump or use external water for 90 seconds to allow the fresh water to agitate the stagnant water on the bottom of the tank and force deposits through the drain opening. Continue repeating adding water and draining until the particles have been cleared from the water remaining in the tank. 4. Replace the Drain Plug and close the Pressure Temperature Relieve Valve. the approximately two quarts of water remining in the tank after draining will not cause damage to the tank should freezing occur. A rotten egg odor (hydrogen sulfide) may be produced when the electro galvanic action of the cladding material releases hydrogen from the water. if sulfur is present in the water supply the two will combine and produce an unpleasant smell. 1. Turn off main water supply. Drain the water heater tank and reinstall drain plug. Remove the pressure-temperature relief valve. Mix solution of 4 parts white vinegar to two parts water. With a funnel, carefully pour solution into tank. 2. Cycle water heater with the above solution, letting it run under normal operation 4-5 times. 3. Remove the drain plug and thoroughly drain all water from the tank. Flush the water heater to remove any sediment. You may flush the tank with air pressure or fresh water. pressure may be applied through either the inlet or outlet valves on the rear of the tank or through the pressure-temperature relief valve coupling located on the front of the unit. TO FLUSH TANK WITH AIR PRESSURE: Insert your air pressure through the pressure-temperature relief valve coupling. With the drain valve open, the air pressure will force the remaining water out of the unit. To flush tank with water pressure: Fresh water should be pumped into the tank with either the onboard pump or external water pressure. Continue this flushing process for approximately 5 minutes, allowing the fresh water to agitate the stagnant water on the bottom of the tank and forcing the deposits through the drain opening. 4. Replace drain plug and pressure-temperature relief valve. 5. Refill tank with fresh water that contains no sulphur. The Atwood water heater is designed for use in a recreation vehicle. If you use your vehicle frequently or for long periods of time, flushing the water heater several times a year will prolong the life of the storage tank. PRESSURE-TEMPERATURE RELIEF VALVE WARNING EXPLOSION • Do not place a valve, plug or reducing coupling on outlet part of pressure-temperature relief valve. 5 1 2 STRAIGHT SECTION VIEW C Hot Water Outlet B Cold Water Inlet From the Pump A G H A 3 B D C D E F I B B A 4 A C 7 5 A B E C A B D F E 6 C WHITE RODGERS 6 ROBERTSHAW 4 O F F 5 6 O N + 7 – PART IDENTIFICATION / PILOT IGNITION / PILOT RELIGHT IDENTIFICATION DES PIÈCES SPARK IGNITION / HEAT EXCHANGE ALLUMAGE PAR ÉTINCELLES / ÉCHANGE DE CHALEUR GAZ- ALLUMAGE DE VEILLEUSE / RALLUMAGE DE VEILLEUSE COMBINATION GAS/ELECTRIC 8 GAZ-ÉLECTRICITÉ COMBINÉS 1 1 2 4 2 4 9 13 13 12 5 17 15 3 10 16 6 9 7 11 6 GALLON 22 LITRES 10 GALLON 38 LITRES ✗ ✗ 90960 91857 90960 91857 5 6 7 8 91604 90028 91601 92615 91603 ✓ 9 10 13 1 2 3 4 9 11 ITEM 91604 90028 91601 93221 91603 ✓ Flue Box Assembly Drain Plug (shown on spark ignition) 1/2” NPT Pressure-Temp. Relief Valve 3/4” NPT Pressure-Temp.Relief Valve Thermostat Main Burner Pilot Assembly Exterior Access Door ALLUMAGE DE VEILLEUSE Réservoir Boîtier du conduit Bouchon de vidange (Cf. allumage électronique) Soupape de décharge de type Soupape de décharge Thermostat Brûleur principal Veilleuse Trappe d'accès extérieur 93801 93804 93803 93801 93804 93803 PILOT RELIGHT Spark Module Electrode Assembly Wiring Harness RALLUMAGE DE VEILLEUSE Module d'allumage Électrode Faisceau électrique SPARK IGNITION ✗ ✗ 12 13 15 16 17 90960 91857 91604 93870 91959 91859 93851 93191 93866 93868 91447 90960 91857 91604 93870 91959 91859 93851 93191 93866 93868 91447 ALLUMAGE PAR ÉTINCELLE Réservoir Boîtier du conduit Bouchon de vidange Soupape de décharge de type Électrovanne Interrupteur Marche/Arrêt noir Interrupteur Marche/Arrêt blanc Circuit imprimé Faisceau électrique Coupure thermique Détecteur d'étincelle Thermostat/ECO 1 ✗ ✗ Tank 1 NS NS ✗ ✗ Tank 92249 93849 92249 93849 REFERENCE 1 2 3 4 PILOT IGNITION Tank Tank Flue Box Assembly Drain Plug Pressure-Temperature Relief Valve Solenoid Valve Black on-Off Switch White On-Off Switch Circuit Board Wiring Harness Thermal Cut Off Spark Probe Thermostat/ECO HEAT EXCHANGE COMBINATION GAS/ELECTRIC Heating Element & Gasket Relay ÉCHANGE DE CHALEUR Réservoir GAZ – ÉLECTRICITÉ COMBINÉS Réservoir Élément de chauffe et joint Relais All tanks includes styrofoam jacket = Tous les réservoirs comprennent une chemise de polystyrène. ✗ ✓ Order by model = Commander selon le modèle Order by color = Commander selon la couleur 8 ATWOOD WATER HEATER LIMITED WARRANTY formed at an authorized Atwood Service Center (a list will be provided at no charge) or as approved by the Consumer Service Department, Atwood Mobile Products, 1120 North Main St., Elkhart, IN 46514 USA. Phone: (574-264-2131). Atwood Mobile Products warrants to the original owner and subject to the 5. Return parts (or water heater) must be shipped to Atwood “Prepaid”. below mentioned conditions, that this product will be free of defects in Credit for shipping costs will be included with the warranty claim. The material or workmanship for a period of two years from the original date of defective parts (or water heater) become the property of Atwood Mobile purchase. Atwood’s liability hereunder is limited to the replacement of the Products and must be returned to the Consumer Service Department, product, repair of the product, or replacement of the product with a reconAtwood Mobile Products, 6320 Kelly Willis Road, Greenbrier, TN ditioned product at the discretion of the manufacturer. This warranty is void 37073 USA. if the product has been damaged by accident, unreasonable use, neglect, 6. This warranty applies only if the unit is installed according to the in-stallatampering or other causes not arising from defects in material workmantion instructions provided and complies with local and state codes. ship. This warranty extends to the original owner of the product only and is 7. The warranty period on replacement parts (or water heater) is the subject to the following conditions: unused portion of the original warranty period or ninety (90) days, 1. For a period of two years from the date of purchase, Atwood will whichever is greater. replace the complete water heater if the inner tank leaks due to corro8. Damage or failure resulting from misuse (including failure to seek proper sion. This warranty includes reasonable labor charges required to repair service), misapplication, alterations, water damage, or freezing replace the complete water heater. are the owner’s responsibility. 2. For two years from the date of purchase, Atwood will repair or replace 9. Atwood does not assume responsibility for any loss of use of vehicle, any part defective in material or workmanship. This warranty includes loss of time, inconvenience, expense for gasoline, telephone, travel, reasonable labor charges, required to remove and replace the part. lodging, loss or damage to personal property or revenues. Some states Service calls to customer’s location are not considered part of these do not allow the exclusion or limitation of incidental or consequential charges and are, therefore, the responsibility of the owner. damages, so the above limitations or exclusions may not apply to you. 3. This warranty does not cover the following items classified as normal 10. Any implied warranties are limited to two (2) years. Some states do not maintenance: allow limitations on how long an implied warranty lasts, so the above lima. adjustment of gas pressure itation may not apply to you. This warranty gives you specific legal rights b. cleaning or replacement of burner orifice and you may also have other rights which vary from state to state. c. cleaning or adjustment of burner tube 11. Replacement parts (components or tanks) purchased outside of the d. cleaning or adjustment of flue original water heater warranty carry a 90 day warranty. This includes e. cleaning or adjustment of pilot and thermocouple the part at no charge and reasonable labor charges to replace it. f. adjustment of pressure-temperature relief valve This Atwood heater is designed for use in recreational vehicles for the purpose g. replacement of thermal cut-off device. of heating water as stated in the “data plate” attached to the water heater. Any 4. In the event of a warranty claim, the owner must contact, in other use, unless authorized in writing by the Atwood Engineering Department, advance, either an authorized Atwood Service Center or the voids this warranty. Atwood Service Department. Warranty claim service must be per-
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Modify Date : 2007:12:13 09:08:29-05:00 Create Date : 2007:12:13 09:08:29-05:00 Metadata Date : 2007:12:13 09:08:29-05:00 Creator Tool : QuarkXPress(tm) 6.1 Format : application/pdf Title : Layout 1 (Page 1) Document ID : uuid:d5a21df4-a984-11dc-b1a6-001451691f42 Instance ID : uuid:e116fb64-a984-11dc-b1a6-001451691f42 Producer : Acrobat Distiller 7.0 for Macintosh Page Count : 9 Creator : QuarkXPress(tm) 6.1EXIF Metadata provided by EXIF.tools