Aurum Electronics AEC-9339B The Intelligent Motion Sensor Tracking Light (Transmitter) User Manual 12 1 AEC 9336B Use Manual
Aurum Electronics Corp. The Intelligent Motion Sensor Tracking Light (Transmitter) 12 1 AEC 9336B Use Manual
User Manaul
THE INTELLIGENT MOTION SENSOR TRACKING LIGHT (DRAFT) INSTALLATION INSTRUCTIONS Read all instructions before proceeding with the installation OVERVIEW OF AEC-9336B Push-button 3 motion sensors INSTALLING THE BULB Unscrew the lamp cover of the luminaire and install a 150W J-type lamp. Re-fit the lamp cover and tighten the screws. SETTING THE CHANNEL Remove the back mounting box from the fixture by unscrewing the screw at the bottom. Set the channel you preferred Re-fit the back mounting box and tighten the screw. Channel 1 Channel 2 Channel 3 Channel 4 IMPORTANT: THE INTALLATION OF THIS FITTING MUST BE DONE BY A QUALIFIED ELECTRICIAN. This fitting must be earthed. Do not mount the luminaire against inflammable surfaces. WARNING ! ! ! The motion detector will not operate correctly if it is installed: BEFORE ATTEMPTING ANY INSTALLATION OR (Ⅰ) Near the outlet of a central heating boiler (Ⅱ) Near air conditioning plant (Ⅲ) Pointing directly at moving vehicles MAINTENANCE, ENSURE THAT THE ELECTRICAL SUPPLY IS SWITCHED OFF AND THE CIRCUIT FUSES REMOVED OR THE CIRCUIT BREAKER IS IN THE “OFF”POSITION. (Ⅳ) Within sight of reflection from moving water (Ⅴ) Where other lamps could shine onto the detector The maximum rating of this luminaire is 150 Watts. Check that the total load of the circuit. Including this luminaire. Does not exceed the rating of the circuit cable. NOTE: This highly responsive unit may occasionally activate due to rapid environmental changes. Allow for approximately 30 seconds warm-up time before the sensor resumes normal activity. MOUNTING THE FITTING To ensure correct operation of the sensor, mount the luminaire that traffic passes across the detector. TOP VIEW GOOD SENSITIVITY LESS SENSITIVITY INSTALLATION AND WIRING INSTRUCTIONS Remove the inset back mounting box from the luminaire. Fit the inset back mounting box onto the wall and tighten the screws at a height that ensures adequate coverage of the area by the infrared detector. The minimum installation height is 2 meters. And the maximum height is 3 meters. NOTE: DO NOT REMOVE THE TAPE UNTIL YOU FINISH THE INSTALLATION. IF THE TAPE COMES OFF THE LIGHT, PLEASE REPLACE IT OR HOLD THE LIGHT HEAD TO AVOID SWIVELING AND DAMAGE THE PRODUCT. WIRING INSTRUCTIONS Feed the cable through the back mounting box and bush the cable entry to avoid abrasion to the cable. Connect the earth wire to the connector opposite the green/yellow cable. Connect the brown phase conductor active to the connector opposite the brown cable and tighten the screws. Connect the blue neutral conductor to the connector opposite the blue cable and tighten the screws. Check that all connections are correct and tight, as any misconnections will damage the detector. Re-fit the fitting to the back mounting box. FUNCTION This light is equipped with 3 motion sensors: zone 1 covers 60 degree, zone 2 covers 100 degrees and zone 3 covers 60 degrees. 220 degrees (maximum) in total for 3 zones. ZONE 2 ZONE 1 ZONE 3 TOTAL DETECTION RANGE The light will switch on for 3 minutes and off automatically when heat/ movement is detected. The factory default: the light on fixed at 3 minutes and works all day. To change the mode to nighttime only, push the button at the bottom of the housing and the hidden LED indicator will turn red under this mode. The light will be on at 3 minutes when detecting any movement at night. Push-button for programmable functions: - All day mode: light, camera and alarm work all day - Nighttime mode: light works at night, camera works all day, alarm works at night Reset function: If the stepper motor of tracking light works abnormal, the hidden LED indicator will flash in red and the light will stop turning automatically. In All Push-button Day mode, the red light will flash for 5 seconds and off for 5 seconds; in Nighttime mode, the red light will flash in regular pattern. Please simply switch off and on the main power to resume the tracking light. Below are the possible abnormal situations. - External force: the light head is blocked by objects or is blown by strong wind and is unable to turn properly, the hidden LED will flash in red to signal users the abnormal situation. - Stepper motor: when stepper motor is going to be out of its lifetime or is damaged, the hidden LED will flash in red to signal users the abnormal situation. Please switch off and on the main power, the tracking light now may or may not resume its operation. If the stepper motor stops working, AEC-9336B becomes a regular motion sensor security light. Left 70° Hidden LED indicator Right 70° OPERATION 1. Turn on the wall switch to activate the light, the light is now under All Day mode: light works on day and night NOTE: Allow for approximately 30 seconds warm-up time before the sensor resumes normal activity. 2. To test, walk through the sensor’s detection area. 3. Movement will activate the sensor and turn the light on, the light will turn the face to the detected zone for approx. 3 minutes. 4. After the light is activated, keep out of detection area and the light will switch off automatically after 3 minutes. The light will be activated again when detecting any movement. If there is continuing movement in the detection zone, the light will stay on until movement ceases. (after 3 minutes) LAMP REPLACEMENT To isolate the unit, first switch off the unit from the mains power. Allow bulb to cool before attempting to remove it. Unscrew the lamp cover and take the old lamp out and replace with new one, close the lamp cover and tighten the screws. WARNING: This fitting will become hot when in use. Allow bulb to cool before touching. NOTE: THE INTELLIGENT MOTION SEN SOR TRACKING LIGHT IS DESIGNED TO ILLUMINATE WHEN THE DETECTION AREA IS ENTERED BY A P ERSON AND WILL DETECT MOVING HEAT SOURC E. THERE IS NO GUARANTEE IMP LIED THAT IT WILL PROVIDE TOTAL SECUR ITY OR PREV ENT ILLEGA L EN TRY. SPECIFICATION Detection Method: Passive Infrared Sensor (with continuously detect function) Sensor Range: 10m x 220° (maximum) Camera: Color CMOS image sensor View angle 60° Transmission frequency: ISM 2.4 GHz Power source: AC 120V Time adjustment: Fixed at 3 minutes approx. Load Rating: J-Type 150 Watts Max. FCC Warning: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Extract Page Count : 4 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:d7310af1-1b6a-40cf-a1ad-83dde5a03c9d Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2008:12:11 09:31:21-08:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:12:11 09:31:42-08:00 Metadata Date : 2008:12:11 09:31:42-08:00 Document ID : uuid:5febb09c-2887-4c16-98eb-182162281e47 Format : application/pdf Title : Microsoft Word - 12-1 AEC-9336B Use Manual.doc Creator : daniel Author : danielEXIF Metadata provided by EXIF.tools