Aurum Electronics AEC-9339B The Intelligent Motion Sensor Tracking Light (Transmitter) User Manual 12 1 AEC 9336B Use Manual

Aurum Electronics Corp. The Intelligent Motion Sensor Tracking Light (Transmitter) 12 1 AEC 9336B Use Manual

User Manaul

Download: Aurum Electronics AEC-9339B The Intelligent Motion Sensor Tracking Light (Transmitter) User Manual 12 1 AEC 9336B Use Manual
Mirror Download [FCC.gov]Aurum Electronics AEC-9339B The Intelligent Motion Sensor Tracking Light (Transmitter) User Manual 12 1 AEC 9336B Use Manual
Document ID1047586
Application IDPWPMZmI8XvM8acik6qkmTA==
Document DescriptionUser Manaul
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize30.88kB (386016 bits)
Date Submitted2008-12-20 00:00:00
Date Available2008-12-20 00:00:00
Creation Date2008-12-11 09:31:21
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2008-12-11 09:31:42
Document TitleMicrosoft Word - 12-1 AEC-9336B Use Manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: daniel

THE INTELLIGENT
MOTION SENSOR TRACKING LIGHT
(DRAFT)
INSTALLATION INSTRUCTIONS
Read all instructions before proceeding with the installation
OVERVIEW OF AEC-9336B
Push-button
3 motion sensors
INSTALLING THE BULB
„
Unscrew the lamp cover of the luminaire and install a
150W J-type lamp.
„
Re-fit the lamp cover and tighten the screws.
SETTING THE CHANNEL
„
Remove the back mounting box from the fixture by
unscrewing the screw at the bottom.
„
Set the channel you preferred
„
Re-fit the back mounting box and tighten the screw.
Channel 1 Channel 2 Channel 3 Channel 4
IMPORTANT: THE INTALLATION OF THIS FITTING MUST BE DONE BY A QUALIFIED ELECTRICIAN.
„
This fitting must be earthed.
„
Do not mount the luminaire against inflammable surfaces.
WARNING ! ! !
„
The motion detector will not operate correctly if it is installed:
BEFORE ATTEMPTING ANY INSTALLATION OR
(Ⅰ) Near the outlet of a central heating boiler
(Ⅱ) Near air conditioning plant
(Ⅲ) Pointing directly at moving vehicles
MAINTENANCE, ENSURE THAT THE
ELECTRICAL SUPPLY IS SWITCHED OFF AND
THE CIRCUIT FUSES REMOVED OR THE
CIRCUIT BREAKER IS IN THE “OFF”POSITION.
(Ⅳ) Within sight of reflection from moving water
(Ⅴ) Where other lamps could shine onto the detector
„
The maximum rating of this luminaire is 150 Watts. Check that the total load of the circuit. Including this luminaire. Does
not exceed the rating of the circuit cable.
NOTE: This highly responsive unit may occasionally activate due to rapid environmental changes. Allow for approximately 30
seconds warm-up time before the sensor resumes normal activity.
MOUNTING THE FITTING
To ensure correct operation of the sensor, mount the luminaire that traffic passes across the detector.
TOP VIEW
GOOD SENSITIVITY
LESS SENSITIVITY
INSTALLATION AND WIRING INSTRUCTIONS
Remove the inset back mounting box from the luminaire.
Fit the inset back mounting box onto the wall and tighten the screws at a
height that ensures adequate coverage of the area by the infrared detector. The minimum installation height is 2 meters.
And the
maximum height is 3 meters.
NOTE: DO NOT REMOVE THE TAPE UNTIL YOU FINISH THE INSTALLATION. IF THE TAPE COMES OFF
THE LIGHT, PLEASE REPLACE IT OR HOLD THE LIGHT HEAD TO AVOID SWIVELING AND DAMAGE THE
PRODUCT.
WIRING INSTRUCTIONS
„
Feed the cable through the back mounting box and bush the cable
entry to avoid abrasion to the cable.
„
Connect the earth wire to the connector opposite the green/yellow
cable.
„
Connect the brown phase conductor active to the connector opposite
the brown cable and tighten the screws.
„
Connect the blue neutral conductor to the connector opposite the blue
cable and tighten the screws.
„
Check that all connections are correct and tight, as any misconnections will damage the detector.
„
Re-fit the fitting to the back mounting box.
FUNCTION
This light is equipped with 3 motion sensors: zone 1 covers 60 degree, zone 2 covers 100 degrees and zone 3 covers 60 degrees.
220 degrees (maximum) in total for 3 zones.
ZONE 2
ZONE 1
ZONE 3
TOTAL DETECTION RANGE
„
The light will switch on for 3 minutes and off automatically when heat/ movement is detected.
„
The factory default: the light on fixed at 3 minutes and works all day.
„
To change the mode to nighttime only, push the button at the bottom of the housing and the hidden LED indicator will turn
red under this mode. The light will be on at 3 minutes when detecting any movement at night.
„
Push-button for programmable functions:
- All day mode: light, camera and alarm work all day
- Nighttime mode: light works at night, camera works all day, alarm works at night
„
Reset function: If the stepper motor of tracking light works abnormal, the hidden
LED indicator will flash in red and the light will stop turning automatically. In All
Push-button
Day mode, the red light will flash for 5 seconds and off for 5 seconds; in Nighttime
mode, the red light will flash in regular pattern. Please simply switch off and on the
main power to resume the tracking light.
Below are the possible abnormal situations.
- External force: the light head is blocked by objects or is blown by strong wind and is unable to turn properly, the hidden LED
will flash in red to signal users the abnormal situation.
- Stepper motor: when stepper motor is going to be out of its lifetime or is damaged, the hidden LED will flash in red to signal
users the abnormal situation. Please switch off and on the main power, the tracking light now may or may not resume its
operation. If the stepper motor stops working, AEC-9336B becomes a regular motion sensor security light.
Left 70°
Hidden LED indicator
Right 70°
OPERATION
1. Turn on the wall switch to activate the light, the light is now under All Day mode: light works on day and night
NOTE: Allow for approximately 30 seconds warm-up time before the sensor resumes normal activity.
2. To test, walk through the sensor’s detection area.
3. Movement will activate the sensor and turn the light on, the light will turn the face to the detected zone for approx. 3 minutes.
4. After the light is activated, keep out of detection area and the light will switch off automatically after 3 minutes. The light
will be activated again when detecting any movement.
If there is continuing movement in the detection zone, the light will stay on until movement ceases. (after 3 minutes)
LAMP REPLACEMENT
To isolate the unit, first switch off the unit from the mains power. Allow bulb to cool before attempting to remove it. Unscrew
the lamp cover and take the old lamp out and replace with new one, close the lamp cover and tighten the screws.
WARNING: This fitting will become hot when in use. Allow bulb to cool before touching.
NOTE: THE INTELLIGENT MOTION SEN SOR TRACKING LIGHT IS DESIGNED TO ILLUMINATE WHEN THE DETECTION
AREA IS ENTERED BY A P ERSON AND WILL DETECT MOVING HEAT SOURC E.
THERE IS NO GUARANTEE IMP LIED
THAT IT WILL PROVIDE TOTAL SECUR ITY OR PREV ENT ILLEGA L EN TRY.
SPECIFICATION
Detection Method:
Passive Infrared Sensor (with continuously detect function)
Sensor Range:
10m x 220° (maximum)
Camera:
Color CMOS image sensor
View angle 60°
Transmission frequency: ISM 2.4 GHz
Power source:
AC 120V
Time adjustment:
Fixed at 3 minutes approx.
Load Rating:
J-Type 150 Watts Max.
FCC Warning:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Extract
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:d7310af1-1b6a-40cf-a1ad-83dde5a03c9d
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2008:12:11 09:31:21-08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:12:11 09:31:42-08:00
Metadata Date                   : 2008:12:11 09:31:42-08:00
Document ID                     : uuid:5febb09c-2887-4c16-98eb-182162281e47
Format                          : application/pdf
Title                           : Microsoft Word - 12-1 AEC-9336B Use Manual.doc
Creator                         : daniel
Author                          : daniel
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VQXAEC-9339B