Automatic Bar Controls MS1108 Master User Manual RX

Sky Channel Technologies (Shenzhen) Ltd. Master RX

user manual

Download: Automatic Bar Controls MS1108 Master User Manual  RX
Mirror Download [FCC.gov]Automatic Bar Controls MS1108 Master User Manual  RX
Document ID1516484
Application IDtveLpJMRrP5qXzzjPMvynw==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.9kB (98690 bits)
Date Submitted2011-08-03 00:00:00
Date Available2011-08-03 00:00:00
Creation Date2011-07-19 15:57:41
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2011-07-19 15:57:41
Document TitleMicrosoft Word - User Manual-RX.doc
Document CreatorPScript5.dll Version 5.2
Document Author: zmp

Master User Manual
FCC Information.
This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced radio/TV technician for help
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including interference that may cause
undesired operation
Canada information:
This device complies with Industry Canada licence‐exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
How to start:
1, Install the two antennas, make sure they are perpendicular to the ground, otherwise
communication distance will be affected.
2, Connect the Ethernet cable or RS232 cable for data link. The Ethernet is more quick and steady
than the COM port. The default setting of the Master is: IP address 192.168.1.121, Subnet mask
255.255.255.0, Default gateway 192.168.1.1, user can change this setting through COM port or PC
direct connection. The Master can obtain a IP address automatically with a DHCP protocol.
3, Plug in power.
4, Configure the Master.
5, Add devices to the Master, add product to the Master.
6, Configure the devices.
7, Set Master date and time, clean old data.
8, Read pour data, the master supports different protocols: Skylink which is integrated in Skyman API,
Harton, Berg, Web API. Any of them can be used as a data reading protocol, but DO NOT use them
at the same time.
2
Panel:
LED indication:
All the 4 LEDs are double color: Red and Green.
Normal mode:
LED 1
LED 2
LED 3
LED 4
Red
Power
Green
Blink Red
RF link
PC link
Card Write
Blink Green
RF link
RF link
Card Read
Green
Blink Red
Blink Green
PC link
Card Write
RF link
Card Read
Boot load mode:
LED 1
LED 2
LED 3
LED 4
Red
Boot mode
Boot mode
Key mode:
In the key mode, the LED(s) blinking means waiting for “ENTER” key, if no key press within
3 seconds, master will return to normal mode. If the LED(s) is on, it means the master is in
corresponding mode.
LEDs(Green)
LED 1
LED 2
LED 3
LED 4
LED 1 & LED2
LED 3 & LED4
LED 2 & LED3
LED 1 & LED4
Description
Force the COM port (the one near the antenna) work in Skylink
protocol temporarily.
Respond to all devices RF data even the devices are not in the
master device list.
Use DHCP to obtain IP address etc from the router and set the IP
3
LED 1 & LED2 &
LED3 & LED4
address temporarily , master will return to normal mode if succeed.
After master program version ‘V1.1.758’, master save the IP
address, Default gateway, Subnet mask and DNS .
Return to normal mode
Button functions:
SELECT button:
Select button function, LED(s) blink before ENTER is pushed, return to normal work mode if
no key is pushed within 4 seconds.
ENTER button:
Normal work mode, when push ENTER key master enters last button function directly and
waiting for ENTER key confirmation or time out.
If the LED(s) is blinking key function mode, confirm entering current key function.
RESET button:
Set the Master IP with 192.168.1.121, 255.255.255.0, 192.168.1.1, set the Protocol with
skylink protocol, set COM port setting with 38400,8,None,1,None. If hold the button for
about 5 seconds, reset the hole PCB;
Various ports:
USB : In boot load mode, the USB works as a removable disk, user can handle the card
memory. In normal work mode, the USB is only for power supply.
COM port on front panel: This port can connect to a micro-printer, or a debug device.
COM port on back panel: Can connect to a PC or POS to send pour data etc.
Ethernet port: Can connect a router or directly to a PC. PC program can read pour data,
configure the master and device, set Master time, add devices etc. In addition, from this port
user can visit the Master’s web page.
Update program:
1) Enter boot load mode, power off the Master, hold the ENTER and SELECT button,
plug in the power, release the button when the LED 1 and LED 2 turn on green, then
LED 1 and LED 2 turn on red. If the Skyman API is using, send a flash correlative
command, the Master will automatically enter boot mode.
2) Write/Verify program and configuration using an API command. Memory card can be
read and write via USB port.
3) Send reset command to reset the Master.
4) Note:
4
a, Master will keep in boot mode if the application program is not present.
b, Master will exit boot load mode if no command is received in a period time.
c, Only eeprom and flash correlative commands are supported in boot mode, other
commands work in only normal work mode.
Error indication:
When power up, Master will check its hardware, if something is wrong Master will give a
beep which indicates different errors .
Beep
LS
SS
Error message
OK
Power error, the input voltage is too high or too low
RAM memory error
RTC error, either the hardware is not good or the time is not
correct.
LL
initialization
LSS
Cannot operate the memory card.
SLS
RF chip does not work
SSL
Fail to initialize the Ethernet chip
SLL
Cannot read the System files
L: long beep, S:short beep.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c320 44.284297, Sun Apr 15 2007 17:19:00
Format                          : application/pdf
Creator                         : zmp
Title                           : Microsoft Word - User Manual-RX.doc
Create Date                     : 2011:07:19 15:57:41+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2011:07:19 15:57:41+08:00
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:21bc1a67-f7d5-48a9-8cd7-36cb732aec58
Instance ID                     : uuid:b5cfe6e2-0253-4cee-b001-e41ae0fa156c
Page Count                      : 4
Author                          : zmp
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZQHMS1108

Navigation menu