Avaya Canada UMTS1900OUT UMTS 1900 Outdoor iBTS User Manual EXHIBIT 11 to 11E Reference Man
Avaya Canada Corporation UMTS 1900 Outdoor iBTS EXHIBIT 11 to 11E Reference Man
Exhibit 8 User Guide
EXHIBIT 11 Reference Manual Applicant: Northern Telecom Ltd. For Certification on: AB6UMTS1900IND This document contains Proprietary Information of Northern Telecom Limited. This information is considered to be CONFIDENTIAL and should be treated appropriately. Nortel Networks Confidential Table of contents About this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Applicability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vocabulary conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . What’s new in this iBTS release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMTS general description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nortel Networks UTRAN solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iBTS description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iBTS operational features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 iBTS tools and utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Presentation of the iBTS outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Presentation of the iBTS indoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Description of the digital shelf of the iBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Description of the RF block of the iBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Configuration rules of the iBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 STSR configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 iBTS physical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Hardware description of the digital shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 CEM (Channel Element Module) description . . . . . . . . . . . . . . . . . . . . . . . . . 28 TRM (Tranceiver Receiver Module) description . . . . . . . . . . . . . . . . . . . . . . . 33 CCM (Core Control Module) description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 GPSAM (GPS and Alarm Module) description . . . . . . . . . . . . . . . . . . . . . . . . 42 External alarm management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 MCA (Manufacturing, Commissioning, and Alarm) module (iBTS indoor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 About the iBTS vi Table of contents Nortel Networks Confidential PCM protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 PFM (Power Filter Module) (iBTS indoor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Hardware description of the RF block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 DDM (Dual Duplexer Module) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 MCPA (Multi Carrier Power Amplifier) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 TMA (Tower Mounted Amplifier) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Interconnection module of the iBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 User space of the iBTS outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Power supply interface of the iBTS outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Power supply interface of the iBTS indoor . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 BIP (Breaker Interface Panel) of the iBTS indoor . . . . . . . . . . . . . . . . . . . . . 75 ac plinth (iBTS indoor 700) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 dc power system shelf of the iBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 dc distribution module description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Rectifier description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 SPCM (Single Power Control Module) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Batteries of the iBTS outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Batteries of the iBTS indoor 700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 External battery cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Cooling system of the iBTS outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Fan tray of the iBTS indoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Physical architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Hardware structure of the iBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 CCM functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential Table of contents vii CEM functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 TRM functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 GPSAM functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Physical interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Iub interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Radio interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Protocol architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Functional architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Software management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 CEM software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 TRM software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 CCM software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 About the iBTS Nortel Networks Confidential Nortel Networks UTRAN solution iRNC The iRNC is the e--mobility Internet RNC. It is the 3GPP--compliant UMTS RNC developed by Nortel Networks. The generic term iRNC is used throughout this document to designate the e--mobility Internet RNC. The iRNC allows mobility between UMTS and GSM networks. The main functions of the iRNC are to control and manage: the RAN (Radio Access Network) the signaling between the different CN elements and the RNS the node Bs the radio resources of the corresponding node Bs. The iRNC houses the following cabinets: the C--Node (Control Node) The C--Node is an ATM--based engine that support UMTS call processing and signaling as well as OAM of both the RNC and the node Bs. the I--Node (Interface Node) This is based on Passport 15000. It is a high--capacity ATM switch, in charge of the connectivity (User Plane) of the iRNC. the Access Node This optional cabinet is used for a PCMx configuration. It is a Passport 7480 switch. The main function of the Access Node is to convert the STM1 links into PCM links and vice versa. iBTS The iBTS is the e--mobility Internet BTS. It is the 3GPP--compliant UMTS node developed by Nortel Networks. The generic term iBTS is used throughout this document to designate the e--mobility Internet BTS. The following types of iBTS are available: e--mobility Internet BTS ---- indoor version (600 and 700) e--mobility Internet BTS ---- outdoor version About the iBTS 8 Nortel Networks Confidential Figure 2 UTRAN architecture UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential iBTS description Introduction A node B is a logical node responsible for radio transmission/reception in one or more cells to/from the User Equipement. A node B provides the following interfaces: the Iub interface towards the iRNC the Uu interface towards the User Equipment (UE) A node B may consists of one or several iBTSs. The iBTS product is a line of products that cover different customers requirements: the outdoor BTS product (iBTS outdoor) the indoor BTS product (iBTS indoor 600 and iBTS indoor 700) The main functions of the iBTS are the following: to provide the means of communication between a UE and a network via Transport Channels. to provide the UE with some physical layer channels which are necessary to synchronize the downlink and also to perform cell selection/reselection and handover preparation to provide measurement information to the RNC for radio resource management (handover, power control) The iBTS is modular in design for easy network growth and flexibility, to manage diverse traffic demands. Common modules are used to grow the iBTS to increase capacity as demand requires. The increase of capacity is provided via the simple addition of modules, as opposed to the entire addition of cabinets. iBTS location The iBTS outdoor can be installed on two types of site: on terraces of buildings at ground level The iBTS indoor can be installed inside premises, if an air exchanger is provided in these premises. iBTSs are connected to their controller (iRNC) in a star configuration. About the iBTS 10 Nortel Networks Confidential iBTS operational features The main characteristics of the iBTS are the following: no need for an extra site cabinet (iBTS outdoor) for user space and batteries easy installation and commissioning a flexible product: possible growth from low to high capacity without any additional cabinets front access only PCM internal protection most common modules between the iBTS outdoor and the iBTS indoor iBTS indoor powered in dc or ac The iBTS is a low capacity solution that can grow in a modular way to full capacity. The iBTS supports the following functions: radio access and modem (modulation/demodulation, frequency up/down--conversion, amplification) call processing (channel set--up and management for both common and dedicated channels, cell management, power control, handover and measurement) configuration and supervision synchronization (to retrieve a highly stable radio frequency from either the network interface) UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 11 iBTS tools and utilities The iBTS has two main maintenance tools: the OAM Access (Operation, Administration and Maintenance) and the TIL (Terminal for Local Installation). The Operation and Maintenance center for Node B is responsible for the configuring and supervising functions. The main OAM functions are the following: operation and maintenance alarm management configuration and supervision performance monitoring The TIL is composed of a laptop PC (with Web browser) connected to the iBTS. The TIL is used to install and commission the iBTS. The TIL performs the following: It displays the existing hardware of the iBTS product. It automatically displays new hardware. It provides basic maintenance and test capabilities for all iBTS modules. It allows users to save reports (alarm, test reports) on the PC. It retrieves the hardware and software module configuration. It downloads new software of iBTS modules. About the iBTS 12 Nortel Networks Confidential Presentation of the iBTS outdoor The iBTS outdoor is a single cabinet closed by two doors. Figure 3 Outside view (iBTS outdoor) UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 13 Figure 4 Inside view (iBTS outdoor) The cabinet is divided into: the iDACS (internet Direct Ambient Cooling System) which is the cooling unit of the cabinet the main compartment the bulkhead which allows cable connection and lightning protection About the iBTS 14 Nortel Networks Confidential The main compartment is divided into two parts: the left part which includes: x the dc power system shelf: the dc distribution module, the SPCM (Single Power Control Module), the rectifiers (up to seven) x the digital shelf x the battery system the right part which includes: x the ac distribution module x the RF block x the user space and its ICO x the interconnection module x the ac filtering box UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 15 Figure 5 Bulkhead front view (iBTS outdoor) About the iBTS Nortel Networks Confidential 21 Description of the digital shelf of the iBTS The digital shelf houses all the digital modules of the iBTS. The digital shelf is common to the iBTS indoor 700 and the iBTS outdoor and houses up to 12 modules. These modules share ten slots in the iBTS indoor cabinet. Backplane functionalities The backplane board is part of the digital shelf. It is in charge of supporting all internal links and electrical interfaces between the modules of the digital shelf. All modules and cables carrying external signals plug into connectors mounted on the backplane board. The backplane board accomodates several high speed signals up to 1.3 Gbit/s. It supports --48 V or + 24 V power supply. The backplane provides Inter--module connections and --48 V dc. Physical description of the digital shelf “T bar” rails are used in the digital shelf to guide the modules during insertion and removal operations. The digital shelf houses up to 10 modules (iBTS indoor 600) or 12 modules (iBTS outdoor and iBTS indoor 700), in complete configuration (for future versions), with flexible positions: CCM (Core Control Module) CEM (Channel Element Module) TRM (Transceiver Receiver Module) GPSAM (GPS interface and Alarm Module) All the modules are removable and are 50--mm wide. All the cables providing interconnection between the modules are mounted at the front of them. About the iBTS 22 Nortel Networks Confidential Figure 11 Front view of the digital shelf (iBTS outdoor and iBTS indoor 700) F=Filler: module available for future versions Figure 12 Front view of the digital shelf (iBTS indoor 600) F=Filler: module available for future versions UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 23 Description of the RF block of the iBTS The RF block contains the MCPA and the DDM modules. The RF block is common to the iBTS indoor and the iBTS outdoor. The number of modules depends on the iBTS configuration. Physical description The RF block contains the RF modules: One MCPA shelf that contains six slots. In the three MCPAs configuration, these MCPAs are housed in slots 1, 3, and 5. There is no electrical backplane in the MCPA shelf: all the interconnection cables are mounted at the front of the MCPAs. One DDM shelf that contains three DDMs. All the cables providing interconnection between the modules are mounted at the front of them. Figure 13 Front view of the MCPA shelf About the iBTS 24 Nortel Networks Confidential Configuration rules of the iBTS The iBTS has the following characteristics: one mode of operation: STSR one frequency carrier Antenna configuration The iBTS can be equipped with: two antennas for single--sector configuration four antennas for bi--sector configuration six antennas for three--sectors configuration Frequency carriers The iBTS supports multi--carriers configuration and allows 5 MHz operation in the STSR configuration. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 25 STSR configuration STSR configuration stands for Sectorial Transmit Sectorial Receive. It is the standard three--sector configuration. The iBTS is logically declared at the iRNC as three cells. The user equipment reports measurements for the three sectors and softer handover is controlled by the network. The power allocation in STSR is independant across sectors. The iBTS supports the STSR1 configuration: one carrier per sector. The STSR1 configuration requires: one TRM which allows the reception of up to 6 signals (3x2) one CCM one CEM which is configured for three sectors x two carriers three MCPAs (one per sector) three DDMs (one per sector) iBTS outdoor The outdoor cabinet equipment layout follows the rules described in the following table: Digital shelf 45 -W 45W configuration STSR1 RF shelf Power CCM TRM CEM GPSAM MCPA DDM Rectifier 4+1 iBTS indoor The indoor cabinet equipment layout follows the rules described in the following table: Digital shelf Configuration STSR1 RF shelf Power CCM TRM CEM GPSAM MCPA DDM Rectifier plinth 7+1 About the iBTS 26 Nortel Networks Confidential iBTS physical characteristics This section gives the physical characteristics of the iBTS cabinet. iBTS outdoor Dimension and weight width: 1,35 m depth: 0,7 m height: 1,3 m weight : x fully equipped: 520 kg x in STSR1 configuration with internal batteries: 426,4 kg iBTS indoor Dimension and weight of the iBTS indoor 600 Width: 0,6 m Depth: 0,6 m Height:1,6 m Weight: 260 kg (fully equipped) Dimension and weight of the iBTS indoor 700 Width: 0,7 m Depth: 0,6 m Height:1,6 m Weight: 325,5 kg (fully equipped) Dimension and weight of the iBTS indoor 700 with ac plinth Width: 0,7 m Depth: 0,6 m Height: 2 m Weight: 513,5 kg (fully equipped) UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 33 TRM (Tranceiver Receiver Module) description The TRM is located in the iBTS digital shelf. In the complete configuration, for future versions, the highest number of TRMs is four. The present version contains only one TRM. About the iBTS 34 Nortel Networks Confidential TRM hardware description Figure 17 Front view of the TRM UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 35 Front panel description The front panel of the TRM module has two corporate leds indicating the TRM status: Green rectangular LED Red triangular LED Status OFF OFF Sleep, unpowered or not inserted ON ON Power up self--test underway ON OFF Module should not be removed ON BLINK Module is partially faulty OFF ON Module may be removed, alarm state, BISTs NOK OFF BLINK Module is waiting for Boot The front panel also has: one “Debug” Ethernet connector (RJ--45 type connector) one “Reset” button accessible through an eye in the front panel three RF outputs (to MCPAs): “Tx A out”, “Tx B out”, and “Tx C out” (SMA connectors) six RF inputs (from DDMs): “Rx in” (radial connectors) one interconnection connector for digital communication between RF modules (D--sub connector) Haardware composition The TRM is made of two boards. one dTRM board, including: x 6 Tx channelizers x 3 Rx channelizers one rTRM board, including: x 3 wideband transmitters x 3 dual 5 MHz receivers About the iBTS 36 Nortel Networks Confidential TRM interfaces Figure 18 TRM interfaces Note: This figure describes the complete configuration (available for future versions) UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 37 Internal interfaces The internal interfaces are the signals exchanged between the rTRM and the dTRM boards. The samples are sent to the rTRM board and are converted into an analog signal. In the opposite direction, the rTRM board digitally converts the six received signals and sends the resulting sample flows to the dTRM board. External interfaces The external interfaces are the following: digital shelf backplane interface: based on the dTRM board CCM interface: based on the common HSSL interface About the iBTS 38 Nortel Networks Confidential CCM (Core Control Module) description The CCM is located in the iBTS digital shelf. In the complete configuration, for future versions, the highest number of CCMs is two. The present version contains only one CCM. CCM hardware description Figure 19 Front view of the CCM UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 39 Front panel description The connectors of the front panel are the following: one “ATM” test port (RJ--45 connector) two “Port 1” and “Port 2” Ethernet ports (10/100 Base T and 10 Base T connectors) used for Ethernet access and TIL connection one “E1/T1” connector (44--pin D--sub female connector) used for E1/T1 connection three timing reference ports (SMB connector) for iBTS commissioning labelled “10 MHz”, “ES Out” (Even Second Output), and “ES In” (Even Second Input) The leds on the front panel are the following: two corporate leds indicating the CCM status: Green rectangular LED Red triangular LED Status OFF OFF BISTs results NOK, Sleep, unpowered or not inserted ON ON Power up self--test underway ON OFF Module should not be removed ON BLINK Module is partially faulty OFF ON Module may be removed, alarm state OFF BLINK Module is waiting for Boot BLINKING OFF, ON, or BLINK Downloading in progress two synchronization status indicators: “Lock” (green led) and “Holdover” (yellow led) one “Activity” led which indicates the module status eight PCM status leds which indicate if the PCM link is OK (green led), if the PCM is in alarm (red led), or if the PCM is in tri--state (amber led) The CCM front panel also has a display witch indicates the synchronization source. The dot on the right of the indication allows to differentiate the synchronized state. Display 1,2,3,4,5,6,7, 8 PCM number a or b GPS 0 or GPS 1 active CCM even second external input holdover mode About the iBTS 40 Nortel Networks Confidential CCM interfaces Signal interfaces One CCM supports up to three wide--band carriers with transmit and receive diversity in a tri--sectored carrier configuration. Each CCM is linked with the CEM and TRM by a point--to--point HSSL connection. The two CCMs are linked by two signals: the IML ATM links: 155 Mbit/s the IMC links: 10 Mbit/s The following figure shows the different interfaces of the CCM. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 41 Figure 20 Data flow of the CCM Note: This figure describes the complete configuration (available for future versions). About the iBTS 42 Nortel Networks Confidential GPSAM (GPS and Alarm Module) description The GPSAM is located on the right side of the iBTS digital shelf. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 43 Hardware description Figure 21 Front view of the GPSAM About the iBTS 44 Nortel Networks Confidential The GPSAM is a single module located on the right--hand side of the iBTS digital shelf. Front panel description The front panel of the GPSAM module has: one ”interco link” (RJ--45 type connector) connector used to connect the interconnection module in case of an extension cabinet one ”Internal bus” (RJ--45 type connector) connector used for the iBTS internal bus link one ”External bus” (RJ--45 type connector) connector used for the iBTS external bus link one three positions switch: “Base”, “Ext. 0”, and “ Ext. 1” which indicates in which cabinet (base cabinet, first extension cabinet, or second extension cabinet) the digital boards are inserted. two “GPS Ant” 15--pin D--sub female connectors for the optional connection of GPS smart receivers, not used in this product release. Leds The front panel of the GPSAM module has two corporate leds indicating the GPSAM status: Green rectangular LED Red triangular LED Status OFF OFF sleep, unpowered or not inserted ON ON power up self--test underway ON OFF operational module OFF ON alarm state TRM interface Power supply The GPSAM is powered with external --48 V dc. The maximum power is estimated at 20 W. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 54 Nortel Networks Confidential Hardware description of the RF block This section describes the modules of the RF block: DDM (Dual Duplexer Module) MCPA (Multi Carrier Power Amplifier) optional TMA (Tower Mashead Amplifier) UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 55 DDM (Dual Duplexer Module) The DDMs are located in the DDM shelf which houses three DDMs. The DDM is used in outdoor or indoor configurations. Hardware description Figure 30 Front view of the DDM About the iBTS 56 Nortel Networks Confidential Front panel description The front panel of the DDM has two corporate leds indicating the DDM status: Green rectangular LED Red triangular LED Status OFF OFF Sleep, unpowered or not inserted ON ON Power up self--test underway ON OFF Module should not be removed ON BLINK Module is partially faulty OFF ON Module may be removed, alarm state OFF BLINK Module is waiting for Boot One two position switch indicates the functioning mode of the DDM: mode with TMA or mode without TMA. Hardware composition The design of the DDM allows an easy transition from receive diversity to transmit diversity. The DDM consists of a double--duplexer LNA chain: one for the main path, the other for the diversity path. The DDM provides the following functions: isolation between transmit and receive signals filtering of the transmitted and received signals to reduce interfering signals DDM interfaces All DDM interfaces are located on the front panel. There are three types of interface: RF interface digital interface power supply interface RF interface Radio interfaces are coaxial cables: two “Antenna” ports, main & diversity (7/16 female connector) two “Transmitter” inputs (N female connector) eight “Rx” outputs (SMA female connector) UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 57 Digital interface The corresponding connector is a 15--pin D--sub female connector. The digital interface allows communication with the TRM. TRM software is able to detect if a DDM is physically connected to this interface. Power supply The DDM is power supplied by --48 V dc. Detailed functional description The main functions of the DDM are the following: one single antenna port for the Tx and Rx paths dedicated isolation between Tx and Rx frequency bands Tx and Rx out--of--band filtering low--noise amplification in Rx frequency bands and signal splitting into four local outputs VSWR alarm monitoring capability TMA dc supplying TMA alarm monitoring suppression of transient voltage suppression from the antenna port following external lightning protection inventory capability active function monitoring About the iBTS 58 Nortel Networks Confidential Figure 31 DDM block diagram The DDM includes two dc/dc converters dedicated to the main and diversity branches: one converter supplies TMA and DDM main the other converter supplies TMA and DDM diversity Two VSWR monitors are also included in the DDM: they are able to monitor RF matching between the antenna and the iBTS. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 59 MCPA (Multi Carrier Power Amplifier) The MCPAs are located in the MCPA shelf which houses up to 6 MCPAs. The present version of the iBTS contains three MCPAs. Hardware description Figure 32 Front view of the MCPA module The front panel of the MCPA module has one led indicating if the MCPA module is operational: the led is green if the module is operational and red if it is not operational. About the iBTS 60 Nortel Networks Confidential The front panel also has one on/off power switch to switch off the input dc supply. All external connections are connected to the MCPA through the front panel. MCPA interface Radio interfaces The front panel has two “RF IN” connectors (SMA 50 : female connector) and one “Transmitter” connector (N female type connector) for RF ouput for radio interface. Interconnection interfaces The front panel has one “Data I/O” connector for digital information exchange with the TRM (25--pins D--sub connector). Power supply interface The front panel has one “Power IN” connector (3--pin 3W3 connector). MCPA functional description The MCPA module provides downlink signal amplification. The aim of the MCPA is to amplify the RF signal delivered by the TRM. The MCPA is connected to the antenna through a duplexer for sectorial configurations. The MCPAs handle up to 1 carrier (5 MHz operation). The MCPA mode of operation is 45 W. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 61 Figure 33 Functional description of an MCPA (only one sector) About the iBTS 62 Nortel Networks Confidential Figure 34 MCPA functional block diagram UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 63 TMA (Tower Mounted Amplifier) In case the cable length between the iBTS cabinet and the antenna is high, an optional TMA is mounted as near as possible from the antenna system in order to improve sensibility. General description The TMA module allows to decrease the overall noise figure of the system by amplifying the receive signal.The TMA module is a LNA (Low Noise Amplifier). It amplifies the received RF signal in the early stages of the reception path before going through the feeders. The TMA enables two single antennas (main and diversity) to be used for up--link and down--link. The TMA is powered from the DDMs through the RF coaxial cable. Figure 35 TMA outside view All external connections are located at the bottom of the TMA module. The RF connectors are 7/16e male connectors. About the iBTS 64 Nortel Networks Confidential Figure 36 TMA block diagram Protection Data and RF lightning protection is performed at the iBTS connectors. Protecting cups provide the TMA connectors with mechanical and environmental protection. The DDMs monitor TMA alarms and report them to the digital shelf through I2C connection. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 65 TMA system overview The optional TMA is a double UMTS TMA module. Figure 37 Double TMA system overview About the iBTS Nortel Networks Confidential 107 TRM functional description Generalities The TRM contains the transmit/receive circuitry for three transmit chains and six receive chains. It performs: modulation and demodulation clock recovery and synchronization digital--analog and analog--digital conversion up and down frequency conversion These functions are performed with the digital and radio boards. The functional block diagram of the TRM is shown in the following figure: Figure 62 Functional block diagram of the TRM Note: This figure describes the complete configuration (available for future versions). About the iBTS 108 Nortel Networks Confidential Digital TRM board (dTRM) The digital board functions are the following: reception of (up to) six transmit signals from the CCM reception of the six signals from the antennas (main and diversity) recovery and distribution of the clock control and monitoring of the radio modules (TRX, MCPA, DDM) supply voltages for radio board Radio TRM board (rTRM) The radio board performs the following functions: in the downlink path x digital--to--analog conversion x frequency up--conversion x amplification in the uplink path x frequency down--conversion x analog--to--digital conversion The rTRM board consists of three transmit chains and three dual receive chains. Detailed functional description General Downlink path The dTRM board receives up to six signals from the CCM. These downlink samples are transferred to the Tx channelizers. The channelizers perform chip level modulation, peak power reduction, filtering, and then deliver the signals (three max) to the D/A converters of the rTRM board. In the analog domain, the digital signals are transformed into RF signals through D/A conversion, modulation, filtering/amplification and translation operations. The final RF signals have the appropriate level to drive the MCPA. The total transmitted power is proportional to the data rate of the codes and the number of these codes (communications). A power control adjusts each RF signal to optimise the total interference level noise between the iBTS and the user equipment. Uplink branch The uplink branch handles three pair--received signals (main and diversity) coming from the antenna via a coupling system which separates transmission from reception. These signals are filtered, amplificated, demodulated, A/D converted and then transmitted to the Rx channelizers in the digital domain. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 109 The receive channelizer receives the six A/D converter signals. It processes the data and transmits them to the CCM. Other functions The TRM also performs the clock generation and recovery operation. The clock is recovered from the link with the CCM and sent to the rTRM board. This board generates the clock signals for the A/D converters of the receiver branch and the A/D converters of the transmitter branch. dTRM board functional description The functions of the dTRM board are the following: It receives the data samples from the CCM, performs data shaping processing on them, then drives the three transmit chains with the resulting data samples. It receives the data samples from the six TRM receive chains, performs data shaping processing on them, then sends the resulting data samples to the CCM. It performs OAM operations on the TRM, the MCPAs and the DDMs. It supplies the rTRM board. Figure 63 Block diagram of the dTRM board Note: This figure describes the complete configuration (available for future versions). About the iBTS 110 Nortel Networks Confidential The dTRM Rx and Tx data processing functions are mainly implemented in the processor of the dTRM and in the channelizers. The dTRM board includes six TX channelizers. Each of them is able to support one UMTS channel, and they can be put in cascade. The transmit possibility is three 3--carrier signals. On the Rx side, the dTRM board allows the reception of up to six single carrier signals. It can implement one of the following solutions: reception of one carrier from three sectors reception of three carriers from an omni cell rTRM board functional description The functions of the rTRM board are the following: It receives digital samples from the dTRM, converts them into analog signals, upconverts to radio UMTS frequency, filters the signal and adjusts the output power for the MCPA input. It filters the input signal, downconverts, filters and samples it, then transmits the digital samples to the dTRM board. The rTRM board consists of three transmit paths at the same radio frequency and three main/diversity paths that can be tuned to three different frequencies. Figure 64 Block diagram of the rTRM transmit part UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01 Nortel Networks Confidential 111 Figure 65 Block diagram of the rTRM receive part About the iBTS 116 Nortel Networks Confidential Radio interface The radio interface consists of six RF ports which correspond to the connection to main and diversity antenna for three sectors. The frequency--dependent DDM module is compatible with the standard UMTS bands: 2110--2170 MHz for downlink 1920--1980 MHz for uplink The impedance of the radio interface is 50 :. Radio cabling 7/16 connectors are located: at the bottom of the cabinet for the iBTS outdoor (bulkhead) at the top of the cabinet for the iBTS indoor The antenna feeders arrive as close as possible to the iBTS cabinet. The interconnection between the feeders and the jumpers is done outside the iBTS. The number of feeders depends on the configuration type. UMT/DCL/DD/0002 411--8111--905 Preliminary 01.06/EN october 2001 UMTS01
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2002:11:08 14:43:12-07:00 Modify Date : 2002:11:08 14:43:12-07:00 Page Count : 49 Creation Date : 2002:11:08 21:43:12Z Mod Date : 2002:11:08 21:43:12Z Producer : Acrobat Distiller 5.0 (Windows) Author : mhossain Metadata Date : 2002:11:08 21:43:12Z Creator : mhossain Title : EXHIBIT 11 to 11E Reference Man.PDFEXIF Metadata provided by EXIF.tools