Avaya Serial Adapter Module Supplement Users Manual Jan 99,

2015-06-01

: Avaya Avaya-Serial-Adapter-Module-Supplement-Users-Manual-734619 avaya-serial-adapter-module-supplement-users-manual-734619 avaya pdf

Open the PDF directly: View PDF PDF.
Page Count: 10

Part No. 303124-A Rev 01
November 1998
*303124-A Rev 01*
Serial Adapter Module
Supplement
ii 303124-A Rev 01
4401 Great America Parkway 8 Federal Street
Santa Clara, CA 95054 Billerica, MA 01821
Copyright © 1998 Bay Networks, Inc.
All rights reserved. Printed in the USA. November 1998.
The information in this document is subject to change without notice. The statements, configurations, technical data,
and recommendations in this document are believed to be accurate and reliable, but are presented without express or
implied warranty. Users must take full responsibility for their applications of any products specified in this document.
The information in this document is proprietary to Bay Networks, Inc.
Trademarks
AN, Optivity, Quick2Config and Bay Networks are registered trademarks and Advanced Remote Node, ANH, ARN,
BayRS, BayStack, BCC, and the Bay Networks logo are trademarks of Bay Networks, Inc.
All other trademarks and registered trademarks are the property of their respective owners.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, Bay Networks, Inc. reserves the
right to make changes to the products described in this document without notice.
Bay Networks, Inc. does not assume any liability that may occur due to the use or application of the product(s) or
circuit layout(s) described herein.
USA Requirements Only
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case users will be required to take whatever measures may be necessary to correct the
interference at their own expense.
European Requirements Only
EN 55 022 Statement
This is to certify that the Bay Networks <product or system name> is shielded against the generation of radio
interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared
by the application of EN 55 022 Class A (CISPR 22).
Warning: This is a Class A product. In a domestic environment, this product may cause radio interference, in which
case, the user may be required to take appropriate measures.
EC Declaration of Conformity
This product conforms (or these products conform) to the provisions of Council Directive 89/336/EEC and
73/23/EEC. The Declaration of Conformity is available on the Bay Networks World Wide Web site at
www.baynetworks.com.
303124-A Rev 01 iii
Japan/Nippon Requirements Only
Voluntary Control Council for Interference (VCCI) Statement
Voluntary Control Council for Interference (VCCI) Statement
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information
Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise.
When such trouble occurs, the user may be required to take corrective actions.
Canada Requirements Only
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (<product or system name>) does not exceed the Class A limits for radio-noise emissions from
digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (<product or system name>) respecte les limites de bruits radioélectriques visant les appareils
numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des
Communications du Canada.
Canada CS-03 Rules and Regulations
Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets
telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal
Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to
the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be installed using an acceptable method of connection. The
customer should be aware that compliance with the above conditions may not prevent the degradation of service in
some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or
alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications
company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines
and internal metallic water pipe system, if present, are connected together. This precaution may be particularly
important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric
inspection authority, or electrician, as appropriate.
iv 303124-A Rev 01
Notice: For equipment using loopstart lines, please note that the Ringer Equivalence Number (REN) assigned to each
terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone
interface. The termination on an interface may consist of any combination of devices subject only to the requirement
that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. The REN is located on the “FCC
Rules Part 68” label located on the bracket of the module, or on the back of the unit.
Canada CS-03 -- Règles et règlements
Avis: L'étiquette d'Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est
conforme aux normes de protection, d'exploitation et de sécurité des réseaux de télécommunications, comme le
prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n'assure
toutefois pas que le matériel fonctionnera à la satisfaction de l'utilisateur.
Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise
locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée de
raccordement. L'abonné ne doit pas oublier qu'il est possible que la conformité aux conditions énoncées ci-dessus
n'empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel homologué doivent être coordonnées par un représentant désigné par le fournisseur.
L'entreprise de télécommunications peut demander à l'utilisateur de débrancher un appareil à la suite de réparations ou
de modifications effectuées par l'utilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la terre de la source d'énergie électrique,
des lignes téléphoniques et des canalisations d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette précaution
est particulièrement importante dans les régions rurales.
Avertissement: L'utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à un service
d'inspection des installations électriques, ou à un électricien, selon le cas.
Avis: Veuillez prendre note que pour tout appareillage supportant des lignes de type “loopstart,” l'indice d'équivalence
de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être
raccordés à une interface. La terminaison d'une interface téléphonique peut consister en une combinaison de quelques
dispositifs, à la seule condition que la somme d'indices d'équivalence de la sonnerie de tous les dispositifs n'excède pas
5. Le REN figure sur l’étiquette “FCC Rules Part 68” située sur le support du module ou à l’arrière de l’unité.
FCC Part 68 Compliance Statement
This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines must be made
using standard plugs and jacks compliant with FCC Part 68. Please note the following:
1. You are required to request service from the telephone company before you connect the unit to a network. When
you request service, you must provide the telephone company with the following data:
When you request T1 Service, you must provide the telephone company with
-- The Facility Interface Code
Provide the telephone company with all the codes below:
- 04DU9-BN (1.544 MB, D4 framing format)
- 04DU9-DN (1.544 MB, D4 framing format with B8ZF coding)
- 04DU9-1KN (1.544 MB, ESF framing format)
- 04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding)
- 04DU9-1ZN (1.544 MB, ANSI ESF and ZBTSI without line power)
The telephone company will select the code it has available.
-- The Service Order Code(s) (SOC): 6.0F
-- The required Universal Service Order Code (USOC) jack: RJ48C
303124-A Rev 01 v
When you request 56K/64K Service, you must provide the telephone company with
-- The Facility Interface Code: 04DU5-56/64
-- The Service Order Code(s) (SOC): 6.0F
-- The required Universal Service Order Code (USOC) jack: RJ48S
When you request V.34 Service, you must provide the telephone company with
-- The required Universal Service Order Code (USOC) jack: RJ11C
-- The make, model number, Ringer Equivalence Number (REN), and FCC Registration number of the
unit
The REN helps you determine the number of devices you can connect to your telephone line and still have
all of those devices ring when your number is called. In most, but not all, areas, the sum of the RENs of all
devices should not exceed 5.0. To be certain of the number of devices you can connect to your line, you
should call your local telephone company to determine the maximum REN for your calling area.
This equipment must not be used on party lines or coin lines.
When you request ISDN “U” Interface Service, you must provide the telephone company with
-- The Facility Interface Code: 02IS5
-- The Service Order Code(s) (SOC): 6.0F
-- The required Universal Service Order Code (USOC) jack: RJ49C
When you request ISDN “S/T” Interface Service, you must provide the telephone company with
-- The Service Order Code(s) (SOC): 6.0N
-- The make, model number, and FCC Registration number of the NT1
Note: ISDN S/T cannot be directly connected to the network.
When you request Primary Rate ISDN Service, you must provide the telephone company with
-- The Facility Interface Code: 04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding)
-- The Service Order Code(s) (SOC): 6.0F
-- The required Universal Service Order Code (USOC) jack: RJ48C
2. Your telephone company may make changes to its facilities, equipment, operations, or procedures that could
affect the proper functioning of your equipment. The telephone company will notify you in advance of such
changes to give you an opportunity to maintain uninterrupted telephone service.
3. If the unit causes harm to the telephone network, the telephone company may temporarily discontinue your
service. If possible, they will notify you in advance, but if advance notice is not practical, you will be notified as
soon as possible and will be informed of your right to file a complaint with the FCC.
4. If you experience trouble with the unit, please contact the Bay Networks Technical Solutions Center in your area
for service or repairs. Repairs should be performed only by service personnel authorized by Bay Networks, Inc.
United States 1-800-2LAN-WAN
Valbonne, France 33-4-92-96-69-68
Sydney, Australia 61-2-9927-8800
Tokyo, Japan 81-3-5402-0180
5. You are required to notify the telephone company when you disconnect the unit from the network.
303124-A Rev 01 1
Using the Serial Adapter Module
This document supplements one of the following guides:
Installing an Adapter Module in a BayStack AN or ANH Router
Installing and Operating BayStack ARN Routers (Chapter 4, “Installing a
WAN Adapter Module”)
Follow the hardware installation steps in the guide for your router, referring to this
document for information specific to the ARN Serial and AN®/ANH Third
Synchronous adapter module. Information in this supplement includes:
“Verifying Router Requirements” on page 1
Attaching Cables” on page 2
“Completing Software Configuration” on page 4
“Interpreting LEDs” on page 4
Verifying Router Requirements
Table 1 shows the minimum versions of boot and diagnostic programmable
read-only memory (PROM) code required for a serial adapter module.
For information on upgrading PROM, see the BayRSUpgrading Routers guide.
Table 1. PROM Diagnostic and Boot Code for Serial Adapter Module
Router Type Code Type Minimum Version Directory File Name
ARN Boot 1.17 arn_proms arnboot.exe
Diagnostic 1.30 arn_proms arndiag.exe
AN/ANH Boot 8.12 an_proms anboot.exe
Diagnostic 5.31 an_proms andiag.exe
Serial Adapter Module Supplement
2303124-A Rev 01
Attaching Cables
Connect the communications cable to the 44-pin DSUB connector on the installed
adapter module.
You install the Serial adapter module in an open adapter module slot on the router,
as follows:
ARN -- one of the two front-panel WAN adapter module slots (Figure 1).
See Installing and Operating BayStack ARN Routers.
AN or 12-port ANH -- the back-panel adapter module slot (Figure 2).
See Installing an Adapter Module in a BayStack AN or ANH Router.
8-port ANH -- the back-panel COM3 slot (Figure 3).
See Installing an Adapter Module in a BayStack AN or ANH Router.
Figure 1. ARN Serial Adapter Module Connector (Slot 2)
To
RS-232,
RS-422,
RS-530,
V.28,
V.35,
or X.21
interface
COM
UD
DD
B1
B2
RLSD
ISDN BRI
withNT1
1
2
Tx
Rx
Cl
Tx
Rx
Cl
10BaseT
Ethernet 1
10BaseT
Ethernet 2
ARN0066A
ARN front panel
Using the Serial Adapter Module
303124-A Rev 01 3
Figure 2. Serial Adapter Module Connector on an AN or 12-Port ANH
Figure 3. Serial Adapter Module Connector on an 8-Port ANH
COM 1
CO M 2
CONSOLE
TX
RX
CL
UTP
100-240V
50-60 Hz
1.0-0.5A
XCVR
RLSD1
RLSD2
RST
L
U
U
L
Third synchronous
interface ANH0133A
COM 1
COM 2
COM 3/Expansion
Third synchronous
interface ANH137A
Serial Adapter Module Supplement
4303124-A Rev 01
Completing Software Configuration
Once you have successfully installed the Serial adapter module, complete the
following software configuration tasks using instructions found in your BayRS
documentation:
For the latest information, be sure to review the Release Notes and Documentation
Changes for your version of BayRS software.
Interpreting LEDs
The Serial adapter module RLSD (Received Line Signal Detection) LED lights
when the serial interface detects data transfer.
The LED will blink on and off during diagnostic testing, but does not indicate data
transfer until you have configured and enabled the software services.
Configuration Task Location of Instructions
Connect the ARN to the network. One of the following:
Installing and Operating BayStack AN
and ANH Routers
Installing and Operating BayStack ARN
Routers
Configuring BayStack Remote Access
Modify the ARN configuration file to add the
Serial adapter module and enable default
software services.
Any of the following:
Configuring and Managing Routers with
Site Manager
Using the Bay Command Console
Configuring Your Router Using the
Quick2Config Tool
Configure line services.
Configuring WAN Line Services
Configure WAN protocol services. Any of the BayRS WAN or System Suite
guides, including:
Configuring IP Services
Configuring Frame Relay Services
Configuring X.25 Services
Configuring PPP Services

Navigation menu